NEC Express5800/R120g-2E Configuration Guide Storage-Rich model Introduction This document contains product and configuration information that will enable you to configure your system. The guide will ensure fast and proper configuration of your NEC Express5800 server. April 25, 2016 Revision 1.0 NEC Corporation CONFIGURATION GUIDE – NEC Express5800/R120g-2E Storage-Rich Contents TECHNICAL SPECIFICATION ........................................................................................ 3 Key Features .......................................................................................................................................... 3 Specification .......................................................................................................................................... 3 EXTERNAL VIEWS ......................................................................................................... 7 Front and Rear Views ........................................................................................................................... 7 Dimensions (mm) ................................................................................................................................ 11 CONFIGURATION DIAGRAM ....................................................................................... 12 EXPANSION SLOT ........................................................................................................ 13 SERVER CONFIGURATION ......................................................................................... 14 1 2 3 4 5 6 7 8 9 Base Models ................................................................................................................................. 14 Processors and Heat Sink .......................................................................................................... 14 2.1 For 2.5-inch Drive Model.................................................................................................... 14 2.2 For 3.5-inch Drive Model.................................................................................................... 15 Memory ......................................................................................................................................... 16 3.1 Memory Configuration........................................................................................................ 16 Internal Hard Disk Drives ............................................................................................................ 19 4.1 RAID Configuration ............................................................................................................ 19 4.2 Internal Drive Configuration for 2.5-inch Drive Model ........................................................ 21 4.3 Supported HDD/SDD ......................................................................................................... 24 2.5-inch PCIe SSD ........................................................................................................................ 27 5.1 2.5-inch PCIeSSD Installation Kit ...................................................................................... 27 5.2 PCIe SSD ........................................................................................................................... 27 Optical Drive ................................................................................................................................. 28 PCI Card ........................................................................................................................................ 28 7.1 Network Interface Controller .............................................................................................. 28 7.2 InfiniBand ........................................................................................................................... 29 7.3 External Storage Controller ............................................................................................... 30 7.4 Serial Port Adapter ............................................................................................................. 31 Other Add-in Components .......................................................................................................... 32 8.1 Redundant Power Supply Module ..................................................................................... 32 8.2 Redundant Fan Kit ............................................................................................................. 32 8.3 Trusted Platform Module Kit .............................................................................................. 32 8.4 Internal Flash Memory ....................................................................................................... 32 8.5 Flash FDD .......................................................................................................................... 32 Add-on Components ................................................................................................................... 33 9.1 17-inch LCD Console Drawer ............................................................................................ 33 9.2 KVM Switch ........................................................................................................................ 33 9.3 Cable Management Arm .................................................................................................... 34 9.4 Server Management License ............................................................................................. 34 REFERENCES............................................................................................................... 35 Boot Mode Setting .............................................................................................................................. 35 Server Management ............................................................................................................................ 36 Endurance of SSD ............................................................................................................................... 37 OS Support Matrix for PCI Cards and Embedded Controller ......................................................... 38 Supported PCI Cards and Installable Slots ...................................................................................... 39 Copyright Notice and Liability Disclaimer ........................................................................................ 40 NEC Corporation Revision 1.0 – April, 2016 2 CONFIGURATION GUIDE – NEC Express5800/R120g-2E Storage-Rich REVISION HISTORY ..................................................................................................... 41 Technical Specification Key Features High performance with the latest Intel® Xeon® processor E5-2600 v4 product family Up to 512 GB of memory capacity, supporting high speed and energy efficient DDR4-2 Up to 26 x 2.5-inch hard drives or twelve 3.5-inch hard drives plus two 2.5-inch hard drives High energy efficiency with power capping feature and 80 PLUS® Platinum power supply Full manageability by integrated EXPRESSSCOPE Engine 3 Specification 2.5-inch Drive Model Model R120g-2E Part Number N8100-2468F Processor Type Intel® Xeon® processor E5-2620 v4 Intel® Xeon® processor E5-2630 v4 Intel® Xeon® processor E5-2650 v4 Clock speed 2.10 GHz 2.20 GHz 2.20 GHz Number of Processors 1 to 2 Cache 20 MB 25 MB 30 MB Cores and Threads 8C-16T 10C-20T 12C-24T Chipset Memory Internal Storage Expansion Slots NEC Corporation Intel® C612 Chipset Type DDR4-2400 Registered DIMM (4/8/16/32GB) Standard Capacity 0 GB Maximum Capacity 512 GB (16 x 32 GB) Memory protection ECC, x4 SDDC, Memory Mirroring, Memory Lockstep, Memory Sparing Standard Capacity 0 GB Maximum Capacity SAS HDD : 46.8 TB (26 x 1.8 TB) SATA HDD : 52 TB (26 x 2 TB) SAS SSD : 10.4 TB ( 26 x 400 GB) SATA SSD : 41.6 TB ( 26 x 1.6 TB) Disk Controller SATA: 6Gb/s (Integrated) SAS: 12Gb/s (Optional) RAID SATA : RAID 0/1/10 (Optional), RAID 5/6/50/60 (Optional) SAS : RAID 0/1/5/6/10/50/60 (Optional) Hot Plug Supported Optical Disk Drive Optional Optical Drive Bays 0 3.5-inch Media Bays 0 Disk Drive Bays 26 Standard Total: 5 slots available 2 PCIe 3.0 x16 (x16 connector) 1 PCIe 3.0 x8 (x8 connector) 1 PCIe 3.0 x8 (x8 connector) (Dual processor configuration only) 1 PCIe 2.0 x4 (x8 connector) 1 Revision 1.0 – April, 2016 3 CONFIGURATION GUIDE – NEC Express5800/R120g-2E Storage-Rich Model Video R120g-2E Controller (VRAM) Integrated in Server Management Controller (32MB) Resolution / Color 1600 x 1200 / 16.7M 2 Interfaces 1 x VGA (15-pin mini D-sub, 1 x rear) 5 x USB3.0 (2 x front, 2 x rear, 1 x internal) 3 x USB2.0 (2 x rear, 1 x internal) 1 to 2 x Serial (9-pin mini D-sub, RS232-C, 1 to 2 x rear) 2 x 1000BASE-T LAN connector (RJ-45, 2 x rear) 1 x Management LAN connector (RJ-45, 1 x rear) Server Management EXPRESSSCOPE Engine 3 Redundant Fan Optional, hot plug Redundant Power Supply Optional, hot plug Power Supply 1 to 2 x 800 Watt or 1000 Watt 80 PLUS® Platinum certified hot plug PSU 100-240 VAC ± 10% 50 / 60 Hz ± 3 Hz, or Power Consumption Max. Config, Idling 349 VA / 347 Watt 350 VA / 348 Watt 352 VA / 350 Watt Max. Config, Operating 755 VA / 750 Watt 813 VA / 807 Watt 893 VA / 886 Watt Acoustic Noise Max. Config, Idling (Sound Pressure Max. Config, Operating 3 Level) Dimensions (W x D x H ) 53.0dB 53.0dB 53.0dB 61.1 dB 62.0 dB 64.2 dB Weight (Minimum / Maximum) 18 kg / 30 kg, 39.68 lbs. / 66.14 lbs. Temperature, Relative Humidity (non-condensing) Operating: 5° to 40° C / 41° to 104° F, 20 to 80% Non-Operating: -10° to 55° C / 14° to 131° F, 20 to 80% Regulatory and Safety FCC, UL, CB, CE, BSMI, UL(Mexico), CCC, RCM, RoHS, WEEE Operating Systems Microsoft® Windows Server® 2008 R2 Standard Microsoft® Windows Server® 2008 R2 Enterprise Microsoft® Windows Server® 2012 Standard Microsoft® Windows Server® 2012 Datacenter Microsoft® Windows Server® 2012 R2 Standard Microsoft® Windows Server® 2012 R2 Datacenter 5 Red Hat Enterprise Linux 6.7 or later (x86_64) 5 Red Hat Enterprise Linux 7.2 or later VMware ESXi™ 5.5 Update 3 VMware ESXi™ 6.0 Update 1 1 2 3 4 5 448.0 x 683.8 x 87.2 mm / 17.6 x 26.9 x 3.4 in (2U) 4 An optional drive cage is required to install more than 24 hard drives. Maximum resolution available via EXPRESSSCOPE Engine 3 remote console is 1280 x 1024 / 65K colors. Noise emission was measured in accordance with ISO 7779. The actual value may vary by the operating environment. Operable up to 35°C (95°F) when N8181-126 Redundant Fan Kit is installed and any of N8150-490/-483/-486/-518 SAS HDD is installed in the rear HDD cage. For Linux support, contact our sales representative or go to the NEC website at: http://www.nec.com/global/prod/express/linux/index.html NEC Corporation Revision 1.0 – April, 2016 4 CONFIGURATION GUIDE – NEC Express5800/R120g-2E Storage-Rich 3.5-inch Drive Model Model R120g-2E Part Number N8100-2470F Processor Type Intel® Xeon® processor E5-2603 v4 Intel® Xeon® processor E5-2620 v4 Intel® Xeon® processor E5-2630 v4 Clock speed 1.70 GHz 2.10 GHz 2.20 GHz Number of Processors 1 to 2 Cache 15 MB 20 MB 25 MB Cores and Threads 6C-6T 8C-16T 10C-20T Chipset Memory Intel® C612 Chipset Type DDR4-2400 Registered DIMM (4/8/16/32GB) Standard Capacity 0 GB Maximum Capacity 512 GB (16 x 32 GB) Memory protection ECC, x4 SDDC, Memory Mirroring, Memory Lockstep, Memory Sparing Standard Capacity 0 GB Maximum Capacity SATA HDD : 72 TB (12 x 6 TB) plus 2.5-inch SATA: 4 TB (2 x 2 TB) 2.5-inch SAS: 3.6 TB (2 x 1.8 TB) 2.5-inch SATA SSD: 3.2 TB (2 x 1.6 TB) 2.5-inch SAS SSD: 800 GB (2 x 400 GB) Disk Controller SATA: 6Gb/s (Integrated) SAS: 12Gb/s (Optional) RAID SATA : RAID 0/1/10 (Optional), RAID 5/6/50/60 (Optional) SAS : RAID 0/1/5/6/10/50/60 (Optional) Hot Plug Supported Optical Disk Drive Optional Optical Drive Bays 0 3.5-inch Media Bays 0 Disk Drive Bays 14 Expansion Slot Standard Total: 5 slots available 2 PCIe 3.0 x16 (x16 connector) 1 PCIe 3.0 x8 (x8 connector) 1 PCIe 3.0 x8 (x8 connector) (Dual processor configuration only) 1 PCIe 2.0 x4 (x8 connector) Video Controller (VRAM) Integrated in Server Management Controller (32MB) Resolution / Color 1600 x 1200 / 16.7M Internal Storage 1 2 Interfaces 1 x VGA (15-pin mini D-sub, 1 x rear) 5 x USB3.0 (2 x front, 2 x rear, 1 x internal) 3 x USB2.0 (2 x rear, 1 x internal) 1 to 2 x Serial (9-pin mini D-sub, RS232-C, 1 to 2 x rear) 2 x 1000BASE-T LAN connector (RJ-45, 2 x rear) 1 x Management LAN connector (RJ-45, 1 x rear) Server Management EXPRESSSCOPE Engine 3 Redundant Fan Optional, hot plug Redundant Power Supply Optional, hot plug NEC Corporation Revision 1.0 – April, 2016 5 CONFIGURATION GUIDE – NEC Express5800/R120g-2E Storage-Rich Model R120g-2E Power Supply 1 to 2 x 800 Watt or 1000 Watt 80 PLUS® Platinum certified hot plug PSU 100-240 VAC ± 10% 50 / 60 Hz ± 3 Hz, or Power Consumption Max. Config, Idling 244 VA / 243 Watt 242 VA / 240 Watt 243 VA / 242 Watt Max. Config, Operating 599 VA / 595 Watt 658 VA / 653 Watt 723 VA / 718 Watt Acoustic Noise Max. Config, Idling (Sound Pressure Max. Config, Operating 3 Level) Dimensions (W x D x H ) 53.0dB 53.0dB 53.0dB 61.1 dB 61.1 dB 62.0 dB Weight (Minimum / Maximum) 18 kg / 31 kg, 39.68 lbs. / 68.34 lbs. Temperature, Relative Humidity (non-condensing) Operating: 5° to 40° C / 41° to 104° F, 20 to 80% Non-Operating: -10° to 55° C / 14° to 131° F, 20 to 80% Regulatory and Safety FCC, UL, CB, CE, BSMI, UL(Mexico), CCC, RCM, RoHS, WEEE Operating Systems Microsoft® Windows Server® 2008 R2 Standard Microsoft® Windows Server® 2008 R2 Enterprise Microsoft® Windows Server® 2012 Standard Microsoft® Windows Server® 2012 Datacenter Microsoft® Windows Server® 2012 R2 Standard Microsoft® Windows Server® 2012 R2 Datacenter 5 Red Hat Enterprise Linux 6.7 or later (x86_64) 5 Red Hat Enterprise Linux 7.2 or later VMware ESXi™ 5.5 Update 3 VMware ESXi™ 6.0 Update 1 1 2 3 4 5 6 448.0 x 683.8 x 87.2 mm / 17.6 x 26.9 x 3.4 in (2U) 4 An optional drive cage is required to install more than 12 hard drives. Maximum resolution available via EXPRESSSCOPE Engine 3 remote console is 1280 x 1024 / 65K colors. Noise emission was measured in accordance with ISO 7779. The actual value may vary by the operating environment. Operable up to 35°C (95°F) when N8181-126 Redundant Fan Kit is installed and any of N8150-490/-483/-486/-518 SAS HDD is installed in the rear HDD cage. For Linux support, contact our sales representative or go to the NEC website at: http://www.nec.com/global/prod/express/linux/index.html 5GB or more memory is required. NEC Corporation Revision 1.0 – April, 2016 6 CONFIGURATION GUIDE – NEC Express5800/R120g-2E Storage-Rich External Views Front and Rear Views Front View for 2.5-inch Drive Model K L M N O P Q E F G H I J D A B C Legend A. 2.5-inch Drive Bays J. BMC RESET Switch B. 2.5-inch Additional HDD Cage Bay K. POWER LED C. Pull-out Tab L. UID LED D. USB Connectors M. Power Capping LED E. POWER Switch N. LINK/ACT LED(LAN1) F. STATUS LED 1 O. LINK/ACT LED(LAN2) G. STATUS LED 2 P. DISK LED 1 H. UID Switch Q. DISK LED 2 I. DUMP (NMI) Switch NEC Corporation Revision 1.0 – April, 2016 7 CONFIGURATION GUIDE – NEC Express5800/R120g-2E Storage-Rich Rear View for 2.5-inch Drive Model E B G C D F A J H I L K Legend A. B. PCI Slots (Low-Profile) G. Serial Port Connector UID Switch/LED Power Supply H. C. AC Inlet I. Management LAN Connector D. AC POWER LED J. LAN Connector E. Additional Power Supply Slot K. USB Connectors F. Display Connector L. 2.5-inch Additional HDD Cage bay NEC Corporation Revision 1.0 – April, 2016 8 CONFIGURATION GUIDE – NEC Express5800/R120g-2E Storage-Rich Front View for 3.5-inch Drive Model J K L M N O P D E F G H I C B A Legend A. 3.5-inch Drive Bays I. BMC RESET Switch B. Pull-out Tab J. POWER LED C. USB Connectors K. UID LED D. POWER Switch L. Power Capping LED E. STATUS LED 1 M. LINK/ACT LED(LAN1) F. STATUS LED 2 N. LINK/ACT LED(LAN2) G. UID Switch O. DISK LED 1 H. Dump (NMI) Switch P. DISK LED 2 NEC Corporation Revision 1.0 – April, 2016 9 CONFIGURATION GUIDE – NEC Express5800/R120g-2E Storage-Rich Rear View for 3.5-inch Drive Model E B G C D F A J H I L K Legend A. PCI Slots (Low-Profile) G. Serial Port Connector B. Power Supply H. UID Switch/LED C. AC Inlet I. Management LAN Connector D. AC POWER LED J. LAN Connector E. Additional Power Supply Slot K. USB Connectors F. Display Connector L. 2.5-inch Additional HDD Cage bay NEC Corporation Revision 1.0 – April, 2016 10 CONFIGURATION GUIDE – NEC Express5800/R120g-2E Storage-Rich Dimensions (mm) Without Cable Arm 87.1 32.7 829.0 88.1 683.8 87.2 482.0 448.0 482.6 With Cable Arm 948.4 867.0 NEC Corporation Revision 1.0 – April, 2016 11 CONFIGURATION GUIDE – NEC Express5800/R120g-2E Storage-Rich Configuration Diagram 2.5-inch Drive Model CHASSIS INSIDE CHASSIS REAR 2.5-inch Hot Plug Drive Cage Standard Components 4x DIMM Slots CPU 1 1x DIMM 4x DIMM Slots Slot5 Slot4 Slot3 Slot2 Slot1 4x DIMM Slots CPU 2 4x DIMM Slots Hot Plug Power Supply 1/2 PSU 1 8x 2.5-inch Drives 2.5-inch Hot Plug Drive Cage 4x Flash Backup Unit Slots Cooling Fan Redundant Cooling Fan 16x 2.5-inch Drives Legend: 2.5-inch Hot Plug Drive Cage RAID Controller PCIe Slot 2xHDD PSU 2 CHASSIS FRONT Minimum required components 3.5-inch Drive Model CHASSIS INSIDE CHASSIS REAR 2.5-inch Hot Plug Drive Cage Standard Components 4x DIMM Slots CPU 1 1x DIMM 4x DIMM Slots Slot5 Slot4 Slot3 Slot2 Slot1 4x DIMM Slots CPU 2 4x DIMM Slots Hot Plug Power Supply 1/2 PSU 1 4x Flash Backup Unit Slots Cooling Fan NEC Corporation Redundant Cooling Fan 12x 3.5-inch Drives Legend: 3.5-inch Hot Plug Drive Cage RAID Controller PCIe Slot 2xHDD PSU 2 CHASSIS FRONT Minimum required components Revision 1.0 – April, 2016 12 CONFIGURATION GUIDE – NEC Express5800/R120g-2E Storage-Rich Expansion Slot Slot 5 Slot 4 Slot 3 Slot 2 Slot 1 Legend Remarks #1 PCIe 3.0 x8, x8 connector, Low-profile, up to 168 mm length #2 PCIe 3.0 x16, x16 connector, Low-profile, up to 200 mm length #3 PCIe 3.0 x8, x8 connector, Low-profile, up to 200 mm length #4 PCIe 3.0 x16, x16 connector, Low-profile, up to 200 mm length #5 PCIe 2.0 x4, x8 connector, Low-profile, up to 168 mm length 2 CPUs required NOTE: Slot #1 is only available in a dual processor configuration. NEC Corporation Revision 1.0 – April, 2016 13 CONFIGURATION GUIDE – NEC Express5800/R120g-2E Storage-Rich Server Configuration 1 Base Models 2.5-inch Drive Model Product Name / Description Part Number NEC Express5800/R120g-2E no processor, no RAM, no HDD, no ODD Including : 1 x 800 Watt 80 PLUS® Platinum Power Supply Unit, Front Bezel, 16 x 2.5-inch Drive Cage, SAS Expander card, 2 sets of Mini-SAS HD cable N8100-2468F NOTE: The base model must be ordered with a processor kit and a memory kit. 3.5-inch Drive Model Product Name / Description Part Number NEC Express5800/R120g-2E no processor, no RAM, no HDD, no ODD Including : 1 x 800 Watt 80 PLUS® Platinum Power Supply Unit, Front Bezel, 12 x 3.5-inch Drive Cage, SAS Expander card, 2 sets of Mini-SAS HD cable N8100-2470F NOTE: The base model must be ordered with a processor kit and a memory kit. 2 Processors and Heat Sink 2.1 For 2.5-inch Drive Model Available sockets: 2 Category Product Name / Description Part Number Processors 1 Processor Required Xeon E5-2620 v4 Processor Kit Intel® Xeon ® Processor E5-2620 v4 (2.10 GHz, 8C/16T, 20 MB) Xeon E5-2630 v4 Processor Kit Intel® Xeon ® Processor E5-2630 v4 (2.20 GHz, 10C/20T, 25 MB) Xeon E5-2650 v4 Processor Kit Intel® Xeon ® Processor E5-2650 v4 (2.20 GHz, 12C/24T, 30 MB) Processor Heat Sink st For 1 Processor N8101-1070F Processor Heat Sink nd For 2 Processor N8101-1079F Heat Sink 1st 2nd N8101-1072F N8101-1073F (Standard) NOTE: Minimum one processor kit from above must be installed. The processors must be the same to configure dual processor system. NEC Corporation Revision 1.0 – April, 2016 14 CONFIGURATION GUIDE – NEC Express5800/R120g-2E Storage-Rich 2.2 For 3.5-inch Drive Model Available sockets: 2 Category Product Name / Description Part Number Processors 1 Processor Required Xeon E5-2603 v4 Processor Kit Intel® Xeon ® Processor E5-2603 v4 (1.70 GHz, 6C/6T, 15 MB) Xeon E5-2620 v4 Processor Kit Intel® Xeon ® Processor E5-2620 v4 (2.10 GHz, 8C/16T, 20 MB) Xeon E5-2630 v4 Processor Kit Intel® Xeon ® Processor E5-2630 v4 (2.20 GHz, 10C/20T, 25 MB) Processor Heat Sink st For 1 Processor N8101-1068F Processor Heat Sink nd For 2 Processor N8101-1079F Heat Sink 1st 2nd N8101-1070F N8101-1072F (Standard) NOTE: Minimum one processor kit from above must be installed. The processors must be the same to configure dual processor system. The maximum number of logical processors supported by OS See the table below for the maximum number of logical processors that you can actually use on your system. Number of Logical Processors Supported by Operating Systems Maximum Available Number of Logical Processors Microsoft Windows Server 2008 R2 Standard (x64) Microsoft Windows Server 2008 R2 Enterprise (x64) 256 1 Microsoft Windows Server 2012 Standard Microsoft Windows Server 2012 Datacenter Microsoft Windows Server 2012 R2 Standard Microsoft Windows Server 2012 R2 Datacenter 640 1 Red Hat Enterprise Linux 6 (x86_64) Red Hat Enterprise Linux 7 240 56 VMware ESXi 5.5 320 56 VMware ESXi 6.0 480 56 1 56 56 The maximum numbers of logical processors when using Hyper-V are below: - Windows Server 2008 R2 : 64 logical processors - Windows Server 2012 : 320 logical processors - Windows Server 2012 R2 : 320 logical processors NEC Corporation Revision 1.0 – April, 2016 15 CONFIGURATION GUIDE – NEC Express5800/R120g-2E Storage-Rich 3 Memory 3.1 Memory Configuration Refer to the section in accordance with your memory configuration: Independent Channel: Refer to 3.1.1 Memory Sparing Configuration: Refer to 3.1.2 Memory Mirroring / Memory Lockstep Configuration: Refer to 3.1.3 Memory Configuration Feature Comparison See the table below for feature comparisons of memory configurations supported. Independent Channel Memory Sparing Memory Lockstep Memory Mirroring Performance Best Better Better Good Data Protection No Multiple single bit error protection No Multiple single bit and multi bit error protection Redundancy No Partly No Fully Data Correction ECC, x4 SDDC ECC, x4 SDDC ECC, x8 SDDC ECC, x4 SDDC Available Memory Full physical memory 3/4 physical memory Full physical memory Half physical memory Available Memory Channels Notes 4 4 4 4 - All DIMMs in the system must be identical. Paired DIMMs must be identical. Paired DIMMs must be identical. 3.1.1 Independent Channel Configuration Available slots: 8 per processor Category Product Name / Description Part Number Registered DIMM (RDIMM) 4GB DDR4-2400 REG Memory Kit (1x4GB) 1 x 4GB Registered ECC DIMM, DDR4-2400(PC4-2400) 8GB DDR4-2400 REG Memory Kit (1x8GB) 1 x 8GB Registered ECC DIMM, DDR4-2400(PC4-2400) 16GB DDR4-2400 REG Memory Kit (1x16GB) 1 x 16GB Registered ECC DIMM, DDR4-2400(PC4-2400) 32GB DDR4-2400 REG Memory Kit (1x32GB) 1 x 32GB Registered ECC DIMM, DDR4-2400(PC4-2400) N8102-686F N8102-687F N8102-688F N8102-689F NOTE: Minimum one memory kit per processor must be installed. It is recommended to install memory kits in multiples of four (four identical DIMMs) for quad-channel symmetric memory configurations to increase memory transfer speed. When two processors are installed, balance the DIMMs across the two processors. At least 5 GB of memory is required for VMware ESXi 5.5 and VMware ESXi 6.0. NEC Corporation Revision 1.0 – April, 2016 16 CONFIGURATION GUIDE – NEC Express5800/R120g-2E Storage-Rich 3.1.2 Memory Sparing Configuration Available slots: 8 per processor Product Name / Description Part Number 16GB DDR4-2400 REG Memory Kit (2x8GB) 2 x 8GB Registered ECC DIMM, DDR4-2400(PC4-2400) 32GB DDR4-2400 REG Memory Kit (2x16GB) 2 x 16GB Registered ECC DIMM, DDR4-2400(PC4-2400) N8102-693 N8102-694 NOTE: Minimum one memory kit per processor must be installed. The configured memories must be identical. The logical memory capacity becomes three-fourths of physical capacity. 3.1.3 Memory Mirroring / Memory Lockstep Configuration Available slots: 8 per processor Product Name / Description Part Number 16GB DDR4-2400 REG Memory Kit (2x8GB) 2 x 8GB Registered ECC DIMM, DDR4-2400(PC4-2400) 32GB DDR4-2400 REG Memory Kit (2x16GB) 2 x 16GB Registered ECC DIMM, DDR4-2400 (PC4-2400) N8102-691 N8102-692 NOTE: Minimum one memory kit per processor must be installed. The logical memory capacity becomes a half of physical capacity on memory mirroring configuration. Maximum Memory Speed See the table below for the actual maximum memory transfer speed in Independent Channel / Memory Sparing Configuration. DDR4 memory speed depends on the type of DIMMs, the native memory bus speed of the memory controller and memory configuration. All memory buses operate at the clock frequency of the DIMM with the lowest frequency. Processor Type Populated DIMMs # of DIMMs per processor DIMM Speed E5-2603 v4 RDIMM: 4, 8, 16, 32 GB - 1866 MHz E5-2620 v4 E5-2630 v4 RDIMM: 4, 8, 16, 32 GB - 2133 MHz E5-2650 v4 RDIMM: 4, 8, 16, 32 GB - 2400 MHz NEC Corporation Revision 1.0 – April, 2016 17 CONFIGURATION GUIDE – NEC Express5800/R120g-2E Storage-Rich Maximum Available Memory See the table below for the maximum memory size that you can actually use on your system. The maximum available memory is less than the maximum physical memory supported by your system because some chipsets require PCI resource space of about 750MB. PCI resource requirements vary depending on the type and the number of PCI cards you are using. Maximum Memory Size Supported by OS 1 32 GB 32 GB 2 TB 512 GB 4 TB 512 GB Red Hat Enterprise Linux 6 (x86_64) Red Hat Enterprise Linux 7 6 TB 512 GB VMware ESXi 5.5 2 4 TB 512 GB VMware ESXi 6.0 3 6 TB 512 GB Microsoft Windows Server 2008 R2 Standard Microsoft Windows Server 2008 R2 Enterprise 1 1 Microsoft Windows Server 2012 Standard 1 Microsoft Windows Server 2012 Datacenter 1 Microsoft Windows Server 2012 R2 Standard Microsoft Windows Server 2012 R2 Datacenter 1 2 3 Maximum Available Memory 1 The maximum available memory size of Hyper-V systems are below: - Windows Server 2008 R2 Standard : 32 GB - Windows Server 2008 R2 Enterprise : 1TB - Windows Server 2012, Windows Server 2012 R2 : 4 TB Up to 1 TB of the main memory is available to each virtual machine. Up to 4TB of main memory is available to each virtual machine. NEC Corporation Revision 1.0 – April, 2016 18 CONFIGURATION GUIDE – NEC Express5800/R120g-2E Storage-Rich 4 Internal Hard Disk Drives 4.1 RAID Configuration Refer to the section in accordance with your disk form factor and RAID configuration. 4.1.1 2.5-inch Drive Model Refer to the section in accordance with your OS and RAID configuration. For example, when you would like to configure RAID 0/1/10 1GB cache with Windows Server 2012 R2, refer to the section 4.2.1 for the required components and then refer to the section 4.3.2 for the hard drives. Operating System Supported RAID configuration RAID and Cache Section Windows Server 2008 R2 KVM in Red Hat Enterprise Linux 6 (x86_64) VMware ESXi RAID 0/1/10 RAID 5/6/50/60 RAID 5/6/50/60 1GB Cache 1GB Cache 2GB Cache 4.2.1 Windows Server 2012 Windows Server 2012 R2 Red Hat Enterprise Linux 6 (x86_64) without KVM feature Red Hat Enterprise Linux 7 RAID 0/1/10 RAID 5/6/50/60 RAID 5/6/50/60 1GB Cache 1GB Cache 2GB Cache 4.2.1 Supported HDD/SSD 4.3.1 4.2.2 4.2.3 4.3.2 4.2.2 4.2.3 NOTE: All drives within a RAID array should be of the same type, capacity and rotation speed. Also, hard drives in the back side (slot 24 to 25) must be in a separate RAID array than RAID arrays of hard drives in the front side (slot 0 to 23). Dedicated Hot Spare / Global Hot Spare are supported by using RAID controller card (PCI Express). However, Global Hot Spare is not supported on the configuration 4.2.1 to 4.2.3 with an optional drive cage (rear side). Also, hard drives in the back side cannot be used as Hot Spare drives of a RAID array of hard drives in the front side and front side drives cannot be used as Hot Spare drives of a RAID array of hard drives in the back side. Up to two kinds of drives selected from SAS 10K HDDs, SAS 15K HDDs, SATA HDDs, SAS SSDs, SATA SSDs (ME) and SATA SSDs (VE) can be mixed in each drive cage. It is recommended to set RAID array configuration drives less than eight per disk group in order to minimize the risk of becoming multiple hard drives failure. To configure a large-capacity RAID array, it is recommended to configure in RAID 6 or RAID 60 in order to minimize the risk of becoming multiple hard drives failure during the RAID rebuilding process. Operable ambient temperature is up to 35°C (95°F) when N8181-126 Redundant Fan Kit is installed and any of N8150-490/-483/-486/-518 SAS HDD is installed in the rear HDD cage. NEC Corporation Revision 1.0 – April, 2016 19 CONFIGURATION GUIDE – NEC Express5800/R120g-2E Storage-Rich 4.1.2 3.5-inch Drive Model Refer to the section in accordance with your OS and RAID configuration. For example, when you would like to configure RAID 0/1/10 1GB cache with Windows Server 2012 R2, refer to the section 4.2.4 for the required components and then refer to the section 4.3.4 and/or 4.3.2 for the hard drives. Operating System Supported RAID configuration RAID and Cache Section Windows Server 2008 R2 KVM in Red Hat Enterprise Linux 6 (x86_64) VMware ESXi RAID 0/1/10 RAID 5/6/50/60 RAID 5/6/50/60 1GB Cache 1GB Cache 2GB Cache 4.2.4 Windows Server 2012 Windows Server 2012 R2 Red Hat Enterprise Linux 6 (x86_64) without KVM feature Red Hat Enterprise Linux 7 RAID 0/1/10 RAID 5/6/50/60 RAID 5/6/50/60 1GB Cache 1GB Cache 2GB Cache 4.2.4 4.2.5 Supported HDD/SSD 3.5-inch: 4.3.3 2.5-inch: 4.3.1 4.2.6 4.2.5 3.5-inch: 4.3.4 2.5-inch: 4.3.2 4.2.6 NOTE: All drives within a RAID array should be of the same type, capacity and rotation speed. Also, hard drives in the back side (slot 24 to 25) must be in a separate RAID array than RAID arrays of hard drives in the front side (slot 0 to 11) for configuration 4.2.4 to 4.2.6. Dedicated Hot Spare / Global Hot Spare are supported by using RAID controller card (PCI Express). However, Global Hot Spare is not supported on the configuration 4.2.4 to 4.2.6 with an optional drive cage (rear side). Also, hard drives in the back side cannot be used as Hot Spare drives of a RAID array of hard drives in the front side and front side drives cannot be used as Hot Spare drives of a RAID array of hard drives in the back side. It is recommended to set RAID array configuration drives less than eight per disk group in order to minimize the risk of becoming multiple hard drives failure. To configure a large-capacity RAID array, it is recommended to configure in RAID 6 or RAID 60 in order to minimize the risk of becoming multiple hard drives failure during the RAID rebuilding process. Operable ambient temperature is up to 35°C (95°F) when N8181-126 Redundant Fan Kit is installed and any of N8150-490/-483/-486/-518 SAS HDD is installed in the rear HDD cage. NEC Corporation Revision 1.0 – April, 2016 20 CONFIGURATION GUIDE – NEC Express5800/R120g-2E Storage-Rich 4.2 Internal Drive Configuration for 2.5-inch Drive Model 4.2.1 Up to 26 Drives with RAID 0/1 Controller with 1GB Cache Category Product Name / Description Part Number Storage Controller Required RAID Controller (1GB, RAID 0/1) LSI MegaRAID SAS 9362-8i RAID 0/1/10, 1GB, Int. 8, PCIe 3.0 x8, SAS 12Gb/s, SATA 6Gb/s Flash Backup Unit for LSI MegaRAID SAS 9362-8i 650mm Cable for Flash Backup Unit included Internal SAS/SATA Cable 1 x mini-SAS to 1 x mini-SAS, 2 sets 2.5-inch Drive Cage 16 x 2.5-inch hot plug drive bays 2.5-inch Hot Plug Drive Cage Kit 8 x 2.5-inch hot plug drive bays Including 2 sets of 1 x Mini SAS HD to 1 x Mini SAS HD cable 2.5-Inch Drive Cage 2 x 2.5-inch hot plug drive bays Including 1 set of 1 x Mini SAS HD to 1 x Mini SAS HD cable and non-hot plug Fan. N8103-176 Flash Backup Recommended Cable Drive Cage Optional Drive Cage (For more than 16 Drives on the front) Optional Drive Cage (Rear side) N8103-181 (Standard) (Standard) N8154-75 N8154-76 NOTE: For Supported HDD/SSD, refer to 4.3.1 for Windows Server 2008R2, Red Hat Enterprise Linux 6(x86_64) with KVM feature, or VMware. Refer to 4.3.2 for Windows Server 2012/2012R2, Red Hat Enterprise Linux 6(x86_64) without KVM feature, or Red Hat Enterprise Linux 7. All drives within a RAID array should be of the same type, capacity and rotation speed. Up to two kinds of drives selected from SAS 10K HDDs, SAS 15K HDDs, SATA HDDs, SAS SSDs, SATA SSDs (ME) and SATA SSDs (VE) can be mixed in each drive cage. 4.2.2 Up to 26 Drives with RAID 5/6 Controller with 1GB Cache Category Product Name / Description Part Number Storage Controller Required RAID Controller (1GB, RAID 0/1/5/6) LSI MegaRAID SAS 9362-8i RAID0/1/5/6/10/50/60, 1GB, Int. 8, PCIe 3.0 x8, SAS 12Gb/s, SATA 6Gb/s Flash Backup Unit for LSI MegaRAID SAS 9362-8i 650mm Cable for Flash Backup Unit included Internal SAS/SATA Cable 1 x mini-SAS to 1 x mini-SAS, 2 sets 2.5-inch Drive Cage 16 x 2.5-inch hot plug drive bays 2.5-inch Hot Plug Drive Cage Kit 8 x 2.5-inch hot plug drive bays Including 2 sets of 1 x Mini SAS HD to 1 x Mini SAS HD cable 2.5-Inch Drive Cage 2 x 2.5-inch hot plug drive bays Including 1 set of 1 x Mini SAS HD to 1 x Mini SAS HD cable and non-hot plug Fan. N8103-177 Flash Backup Recommended Cable Drive Cage Optional Drive Cage (For more than 16 Drives on the front) Optional Drive Cage (Rear side) N8103-181 (Standard) (Standard) N8154-75 N8154-76 NOTE: For Supported HDD/SSD, refer to 4.3.1 for Windows Server 2008R2, Red Hat Enterprise Linux 6(x86_64) with KVM feature, or VMware. Refer to 4.3.2 for Windows Server 2012/2012R2, Red Hat Enterprise Linux 6(x86_64) without KVM feature, or Red Hat Enterprise Linux 7. All drives within a RAID array should be of the same type, capacity and rotation speed. Up to two kinds of drives selected from SAS 10K HDDs, SAS 15K HDDs, SATA HDDs, SAS SSDs, NEC Corporation Revision 1.0 – April, 2016 21 CONFIGURATION GUIDE – NEC Express5800/R120g-2E Storage-Rich SATA SSDs (ME) and SATA SSDs (VE) can be mixed in each drive cage. 4.2.3 Up to 26 Drives with RAID 5/6 Controller with 2 GB Cache Category Product Name / Description Part Number Storage Controller Required RAID Controller (2GB, RAID 0/1/5/6) LSI MegaRAID SAS 9362-8i RAID0/1/5/6/10/50/60, 2GB, Int. 8, PCIe 3.0 x8, SAS 12Gb/s, SATA 6Gb/s Flash Backup Unit for LSI MegaRAID SAS 9362-8i 650mm Cable for Flash Backup Unit included Internal SAS/SATA Cable 1 x mini-SAS to 1 x mini-SAS, 2 sets 2.5-inch Drive Cage 16 x 2.5-inch hot plug drive bays 2.5-inch Hot Plug Drive Cage Kit 8 x 2.5-inch hot plug drive bays Including 2 sets of 1 x Mini SAS HD to 1 x Mini SAS HD cable 2.5-Inch Drive Cage 2 x 2.5-inch hot plug drive bays Including 1 set of 1 x Mini SAS HD to 1 x Mini SAS HD cable and non-hot plug Fan. N8103-178 Flash Backup Recommended Cable Drive Cage Optional Drive Cage (For more than 16 Drives on the front) Optional Drive Cage (Rear side) N8103-181 (Standard) (Standard) N8154-75 N8154-76 NOTE: For Supported HDD/SSD, refer to 4.3.1 for Windows Server 2008R2, Red Hat Enterprise Linux 6(x86_64) with KVM feature, or VMware. Refer to 4.3.2 for Windows Server 2012/2012R2, Red Hat Enterprise Linux 6(x86_64) without KVM feature, or Red Hat Enterprise Linux 7. All drives within a RAID array should be of the same type, capacity and rotation speed. Up to two kinds of drives selected from SAS 10K HDDs, SAS 15K HDDs, SATA HDDs, SAS SSDs, SATA SSDs (ME) and SATA SSDs (VE) can be mixed in each drive cage. 4.2.4 3.5-inch and 2.5-inch Drives with RAID 0/1 Controller with 1GB Cache Category Product Name / Description Part Number Storage Controller Required RAID Controller (1GB, RAID 0/1) LSI MegaRAID SAS 9362-8i RAID 0/1/10, 1GB, Int. 8, PCIe 3.0 x8, SAS 12Gb/s, SATA 6Gb/s Flash Backup Unit for LSI MegaRAID SAS 9362-8i 650mm Cable for Flash Backup Unit included Internal SAS/SATA Cable 1 x Mini SAS HD to 1 x Mini SAS HD, 2 sets 3.5-inch Drive Cage 12 x 3.5-inch hot plug drive bays 2.5-Inch Drive Cage 2 x 2.5-inch hot plug drive bays Including 1 set of 1 x Mini SAS HD to 1 x Mini SAS HD cable and non-hot plug Fan. N8103-176 Flash Backup Recommended Cable Drive Cage Optional Drive Cage (Rear side) N8103-181 (Standard) (Standard) N8154-76 NOTE: For Supported HDD/SSD, refer to 4.3.3 (3.5-inch) and 4.3.1 (2.5-inch) for Windows Server 2008R2, Red Hat Enterprise Linux 6(x86_64) with KVM feature, or VMware. Refer to 4.3.4 (3.5-inch) and 4.3.2 (2.5-inch) for Windows Server 2012/2012R2, Red Hat Enterprise Linux 6(x86_64) without KVM feature, or Red Hat Enterprise Linux 7. All drives within a RAID array should be of the same type, capacity and rotation speed. NEC Corporation Revision 1.0 – April, 2016 22 CONFIGURATION GUIDE – NEC Express5800/R120g-2E Storage-Rich 4.2.5 3.5-inch and 2.5-inch Drives with RAID 5/6 Controller with 1GB Cache Category Product Name / Description Part Number Storage Controller Required RAID Controller (1GB, RAID 0/1/5/6) LSI MegaRAID SAS 9362-8i RAID0/1/5/6/10/50/60, 1GB, Int. 8, PCIe 3.0 x8, SAS 12Gb/s, SATA 6Gb/s Flash Backup Unit for LSI MegaRAID SAS 9362-8i 650mm Cable for Flash Backup Unit included Internal SAS/SATA Cable 1 x Mini SAS HD to 1 x Mini SAS HD, 2 sets 3.5-inch Drive Cage 12 x 3.5-inch hot plug drive bays 2.5-Inch Drive Cage 2 x 2.5-inch hot plug drive bays Including 1 set of 1 x Mini SAS HD to 1 x Mini SAS HD cable and non-hot plug Fan. N8103-177 Flash Backup Recommended Cable Drive Cage Optional Drive Cage (Rear side) N8103-181 (Standard) (Standard) N8154-76 NOTE: For Supported HDD/SSD, refer to 4.3.3 (3.5-inch) and 4.3.1 (2.5-inch) for Windows Server 2008R2, Red Hat Enterprise Linux 6(x86_64) with KVM feature, or VMware. Refer to 4.3.4 (3.5-inch) and 4.3.2 (2.5-inch) for Windows Server 2012/2012R2, Red Hat Enterprise Linux 6(x86_64) without KVM feature, or Red Hat Enterprise Linux 7. All drives within a RAID array should be of the same type, capacity and rotation speed. 4.2.6 3.5-inch and 2.5-inch Drives with RAID 5/6 Controller with 2GB Cache Category Product Name / Description Part Number Storage Controller Required RAID Controller (2GB, RAID 0/1/5/6) LSI MegaRAID SAS 9362-8i RAID0/1/5/6/10/50/60, 2GB, Int. 8, PCIe 3.0 x8, SAS 12Gb/s, SATA 6Gb/s Flash Backup Unit for LSI MegaRAID SAS 9362-8i 650mm Cable for Flash Backup Unit included Internal SAS/SATA Cable 1 x Mini SAS HD to 1 x Mini SAS HD, 2 sets 3.5-inch Drive Cage 12 x 3.5-inch hot plug drive bays 2.5-Inch Drive Cage 2 x 2.5-inch hot plug drive bays Including 1 set of 1 x Mini SAS HD to 1 x Mini SAS HD cable and non-hot plug Fan. N8103-178 Flash Backup Recommended Cable Drive Cage Optional Drive Cage (Rear side) N8103-181 (Standard) (Standard) N8154-76 NOTE: For Supported HDD/SSD, refer to 4.3.3 (3.5-inch) and 4.3.1 (2.5-inch) for Windows Server 2008R2, Red Hat Enterprise Linux 6(x86_64) with KVM feature, or VMware. Refer to 4.3.4 (3.5-inch) and 4.3.2 (2.5-inch) for Windows Server 2012/2012R2, Red Hat Enterprise Linux 6(x86_64) without KVM feature, or Red Hat Enterprise Linux 7. All hard drives within a RAID array should be of the same capacity and rotation speed. NEC Corporation Revision 1.0 – April, 2016 23 CONFIGURATION GUIDE – NEC Express5800/R120g-2E Storage-Rich 4.3 Supported HDD/SDD 4.3.1 2.5-inch drives for RAID Controller Configuration (1) For Windows Server 2008R2, KVM in Red Hat Enterprise Linux 6(x86_64), or VMware Category Drive For 2.5-inch drive model: Standard : 16 slots available Max : 26 slots available SAS HDD (512n) For 3.5-inch drive model: 2 slots available SATA HDD (512n) SAS SSD (ME) SATA SSD (ME) SATA SSD (VE) Product Name / Description Part Number 300GB 10K Hot Plug 2.5-inch SAS HDD 1 x 300 GB SAS HDD, 2.5-inch, 12Gb/s, 10,000 rpm, 512n sector 450GB 10K Hot Plug 2.5-inch SAS HDD 1 x 450 GB SAS HDD, 2.5-inch, 12Gb/s, 10,000 rpm, 512n sector 600GB 10K Hot Plug 2.5-inch SAS HDD 1 x 600 GB SAS HDD, 2.5-inch, 12Gb/s, 10,000 rpm, 512n sector 900GB 10K Hot Plug 2.5-inch SAS HDD 1x 900 GB SAS HDD, 2.5-inch, 12Gb/s, 10,000 rpm, 512n sector 1.2TB 10K Hot Plug 2.5-inch SAS HDD 1 x 1.2TB SAS HDD, 2.5-inch, 12Gb/s, 10,000 rpm, 512n sector 300GB 15K Hot Plug 2.5-inch SAS HDD 1x 300 GB SAS HDD, 2.5-inch, 12Gb/s, 15,000 rpm, 512n sector 450GB 15K Hot Plug 2.5-inch SAS HDD 1x 450 GB SAS HDD, 2.5-inch, 12Gb/s, 15,000 rpm, 512n sector 600GB 15K Hot Plug 2.5-inch SAS HDD 1x 600 GB SAS HDD, 2.5-inch, 12Gb/s, 15,000 rpm, 512n sector 500GB 7.2K Hot Plug 2.5-inch SATA HDD 1 x 500 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm, 512n sector 1TB 7.2K Hot Plug 2.5-inch SATA HDD 1 x 1 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm, 512n sector 2TB 7.2K Hot Plug 2.5-inch SATA HDD 1 x 2 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm, 512n sector 200GB Hot Plug 2.5-inch SAS SSD 1 x 200 GB SAS SSD, eMLC, 2.5-inch, 12Gb/s, 512n sector 400GB Hot Plug 2.5-inch SAS SSD 1 x 400 GB SAS SSD, eMLC, 2.5-inch, 12Gb/s, 512n sector N8150-479 200GB Hot Plug 2.5-inch SATA SSD 1 x 200 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, ME 400GB Hot Plug 2.5-inch SATA SSD 1 x 400 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, ME 800GB Hot Plug 2.5-inch SATA SSD 1 x 800 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, ME 200GB Hot Plug 2.5-inch SATA SSD 1 x 200 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, VE 400GB Hot Plug 2.5-inch SATA SSD 1 x 400 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, VE 800GB Hot Plug 2.5-inch SATA SSD 1 x 800 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, VE 1.6TB Hot Plug 2.5-inch SATA SSD 1 x 1.6 TB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, VE N8150-725 N8150-480 N8150-481 N8150-482 N8150-483 N8150-485 N8150-486 N8150-518 N8150-488 N8150-489 N8150-527 N8150-721 N8150-722 N8150-726 N8150-727 N8150-732 N8150-733 N8150-734 N8150-735 NOTE: NEC Corporation Revision 1.0 – April, 2016 24 CONFIGURATION GUIDE – NEC Express5800/R120g-2E Storage-Rich All drives within a RAID array should be of the same type, capacity and rotation speed. Up to two kinds of drives selected from SAS 10K HDDs, SAS 15K HDDs, SATA HDDs, SAS SSDs, SATA SSDs (ME) and SATA SSDs (VE) can be mixed in each drive cage. For monitoring SATA SSD life on VMware, NEC ESMPRO Manager Ver.6.05 or later is required. Please download the latest version on the NEC web site. The 2.5-inch SAS/SATA SSDs have limited lifetime. Refer to Endurance of SSD for details. 4.3.2 2.5-inch drives for RAID Controller Configuration (2) For Windows Server 2012/2012R2, Red Hat Enterprise Linux 6(x86_64) without KVM, or Red Hat Enterprise Linux 7 Category Drive For 2.5-inch drive model: Standard : 16 slots available Max : 26 slots available SAS HDD (512n) For 3.5-inch drive model: 2 slots available SAS HDD (4Kn) SATA HDD (512n) SAS SSD (ME) SATA SSD (ME) NEC Corporation Product Name / Description Part Number 300GB 10K Hot Plug 2.5-inch SAS HDD 1 x 300 GB SAS HDD, 2.5-inch, 12Gb/s, 10,000 rpm, 512n sector 450GB 10K Hot Plug 2.5-inch SAS HDD 1 x 450 GB SAS HDD, 2.5-inch, 12Gb/s, 10,000 rpm, 512n sector 600GB 10K Hot Plug 2.5-inch SAS HDD 1 x 600 GB SAS HDD, 2.5-inch, 12Gb/s, 10,000 rpm, 512n sector N8150-479 900GB 10K Hot Plug 2.5-inch SAS HDD 1x 900 GB SAS HDD, 2.5-inch, 12Gb/s, 10,000 rpm, 512n sector 1.2TB 10K Hot Plug 2.5-inch SAS HDD 1 x 1.2TB SAS HDD, 2.5-inch, 12Gb/s, 10,000 rpm, 512n sector 300GB 15K Hot Plug 2.5-inch SAS HDD 1x 300 GB SAS HDD, 2.5-inch, 12Gb/s, 15,000 rpm, 512n sector 450GB 15K Hot Plug 2.5-inch SAS HDD 1x 450 GB SAS HDD, 2.5-inch, 12Gb/s, 15,000 rpm, 512n sector 600GB 15K Hot Plug 2.5-inch SAS HDD 1x 600 GB SAS HDD, 2.5-inch, 12Gb/s, 15,000 rpm, 512n sector 1.8TB 10K Hot Plug 2.5-inch SAS HDD 1x 1.8TB SAS HDD, 2.5-inch, 12Gb/s, 10,000 rpm, 4Kn sector N8150-482 500GB 7.2K Hot Plug 2.5-inch SATA HDD 1 x 500 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm, 512n sector 1TB 7.2K Hot Plug 2.5-inch SATA HDD 1 x 1 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm, 512n sector 2TB 7.2K Hot Plug 2.5-inch SATA HDD 1 x 2 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm, 512n sector 200GB Hot Plug 2.5-inch SAS SSD 1 x 200 GB SAS SSD, eMLC, 2.5-inch, 12Gb/s, 512n sector 400GB Hot Plug 2.5-inch SAS SSD 1 x 400 GB SAS SSD, eMLC, 2.5-inch, 12Gb/s, 512n sector N8150-488 200GB Hot Plug 2.5-inch SATA SSD 1 x 200 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, ME 400GB Hot Plug 2.5-inch SATA SSD 1 x 400 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, ME N8150-725 Revision 1.0 – April, 2016 N8150-480 N8150-481 N8150-483 N8150-485 N8150-486 N8150-518 N8150-490 N8150-489 N8150-527 N8150-721 N8150-722 N8150-726 25 CONFIGURATION GUIDE – NEC Express5800/R120g-2E Storage-Rich SATA SSD (VE) 800GB Hot Plug 2.5-inch SATA SSD 1 x 800 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, ME 200GB Hot Plug 2.5-inch SATA SSD 1 x 200 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, VE 400GB Hot Plug 2.5-inch SATA SSD 1 x 400 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, VE 800GB Hot Plug 2.5-inch SATA SSD 1 x 800 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, VE 1.6TB Hot Plug 2.5-inch SATA SSD 1 x 1.6 TB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, VE N8150-727 N8150-732 N8150-733 N8150-734 N8150-735 NOTE: All drives within a RAID array should be of the same type, capacity and rotation speed. Up to two kinds of drives selected from SAS 10K HDDs, SAS 15K HDDs, SATA HDDs, SAS SSDs, SATA SSDs (ME) and SATA SSDs (VE) can be mixed in each drive cage. The 4Kn sector drives are make-to-order products. Please consult your sales representative in regard to production lead time. When you select 4KB sector HDD, confirm whether your applications support hard drives with 4 KB sector size. For more information, visit the NEC website at: http://www.nec.com/en/global/prod/express/svropt/hdd/collateral/4KHDD_Precautions_EN.pdf 512n sector HDD and 4Kn sector HDD cannot be mixed. The 2.5-inch SAS/SATA SSDs have limited lifetime. Refer to Endurance of SSD for details. 4.3.3 3.5-inch drives for RAID Controller Configuration (1) For Windows Server 2008R2, VMware or KVM in Red Hat Enterprise Linux 6(x86_64) Category Drive 12 slots available 3.5-inch SATA HDD (512n) Product Name / Description Part Number 500GB 7.2K Hot Plug 3.5-inch SATA HDD 1 x 500 GB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512n Sector 1TB 7.2K Hot Plug 3.5-inch SATA HDD 1 x 1 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512n Sector 2TB 7.2K Hot Plug 3.5-inch SATA HDD 1 x 2 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512n Sector 3TB 7.2K Hot Plug 3.5-inch SATA HDD 1 x 3 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512n Sector 4TB 7.2K Hot Plug 3.5-inch SATA HDD 1 x 4 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512n Sector N8150-524 N8150-504 N8150-505 N8150-506 N8150-507 NOTE: All drives within a RAID array should be of the same type, capacity and rotation speed. 4.3.4 3.5-inch drives for RAID Controller Configuration (2) For Windows Server 2012/2012R2 or Red Hat Enterprise Linux 6(x86_64) without KVM, or Red Hat Enterprise Linux 7 Category Drive 12 slots available NEC Corporation 3.5-inch SATA HDD (512n) Product Name / Description Part Number 500GB 7.2K Hot Plug 3.5-inch SATA HDD 1 x 500 GB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512n Sector 1TB 7.2K Hot Plug 3.5-inch SATA HDD 1 x 1 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512n Sector 2TB 7.2K Hot Plug 3.5-inch SATA HDD 1 x 2 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512n Sector 3TB 7.2K Hot Plug 3.5-inch SATA HDD 1 x 3 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512n Sector 4TB 7.2K Hot Plug 3.5-inch SATA HDD 1 x 4 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512n Sector N8150-524 Revision 1.0 – April, 2016 N8150-504 N8150-505 N8150-506 N8150-507 26 CONFIGURATION GUIDE – NEC Express5800/R120g-2E Storage-Rich 3.5-inch SATA HDD (4Kn) 6TB 7.2K Hot Plug 3.5-inch SATA HDD 1 x 6 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 4Kn Sector N8150-503 NOTE: All drives within a RAID array should be of the same type, capacity and rotation speed. The 4Kn sector drives are make-to-order products. Please consult your sales representative in regard to production lead time. When you select 4KB sector HDD, confirm whether your applications support hard drives with 4 KB sector size. For more information, visit the NEC website at: http://www.nec.com/en/global/prod/express/svropt/hdd/collateral/4KHDD_Precautions_EN.pdf 512n sector HDD and 4Kn sector HDD cannot be mixed. 5 2.5-inch PCIe SSD 5.1 2.5-inch PCIeSSD Installation Kit Product Name / Description Part Number 2.5-inch PCIeSSD Installation Kit 2.5-inch Drive Cage for 4 x SDDs, PCIe SSD switch card, and PCIe cable NOTE: This option is for 2.5-inch Drive Model only N8118-304 NOTE: This option is available for 2.5-inch Drive Model only. One PCIe slot is required to install the PCIe SSD switch card. 2.5-inch Additional HDD Cage Bay on the front side is used to install 2.5-inch PCIeSSDs. Therefore, the 2.5-inch Hot Plug Drive Cage Kit N8154-75 cannot be installed at the same time. Four PCIe SSDs can be installed The PCIe SSD slots do not support hot-plug. Operating system cannot be installed on any PCIe SSD. 5.2 PCIe SSD Category Product Name / Description Part Number PCIe SSD 4 slots available 800GB Non-Hot Plug 2.5-inch PCIe SSD - 1x 800 GB PCIe SSD, 2.5-inch N8118-500 NOTE: 2.5-inch PCIeSSD Installation Kit is required to install this product. Warranty period is 3 years (36 months) or until the total bytes of written value (TBW) exceeds the limit value, whichever occurs first. It is recommended to check the TBW periodically. Operating system cannot be installed on any PCIe SSD. NEC Corporation Revision 1.0 – April, 2016 27 CONFIGURATION GUIDE – NEC Express5800/R120g-2E Storage-Rich 6 Optical Drive Category Product Name / Description Part Number External External DVD Super MULTI Drive USB, Slim DVD Super Multi drive, not including writing software N8160-97F NOTE: Up to 1 optical drive can be connected. 7 PCI Card Please refer to Supported PCI Cards and Installable Slots with regard to the position of PCI slot which can mount PCI card supported. 7.1 Network Interface Controller Category Adapter 1GbE 10GbE SFP+ Module Product Name / Description Part Number 1000BASE-T Adapter Broadcom ® BCM5718 Gigabit Ethernet Controller PCIe 2.0 x1 Dual Port 1000BASE-T Adapter Broadcom ® BCM5718 Gigabit Ethernet Controller PCIe 2.0 x1 Dual Port 1000BASE-T Adapter Intel® 82580 Gigabit Ethernet Controller PCIe 2.0 x4 NOTE: - PXE boot is not supported on UEFI environment. Quad Port 1000BASE-T Adapter Broadcom ® BCM5719 Gigabit Ethernet Controller PCIe 2.0 x4 NOTE: - Network cables with RJ-45 plug covers cannot be used. N8104-150 10GBASE SFP+ Adapter (SFP+/2ch) Qlogic NetXtreme II BCM57810S PCIe 2.0 x8, Low Profile / Full Height NOTE: - N8104-129 SFP+ Module is required to connect with an optical cable. Dual Port 10GBASE-T Adapter Intel® Ethernet Controller X540 PCIe 2.0(x8) , Low Profile / Full Height Dual Port 10GBASE-T Adapter Intel® Ethernet Controller X550 PCIe 3.0 x4, Low Profile / Full Height SFP+ Module (10G-SR) 1 x SFP+ Module for N8104-149 N8104-149 N8104-151 N8104-145 N8104-152 N8104-153 N8104-157 N8104-129 NOTE: Supports up to three 10GbE network adapters in a single-processor configuration, and up to five in a dual-processor configuration. Network performance may be reduced depending on the applications and memory performance when three or more 10Gb Network Adapters are installed. For VMware ESXi 5.5 and ESXi 6.0, there are some limitations concerning the number of installable PCI cards. Refer to Supported PCI Cards and Installable Slots for details. NEC Corporation Revision 1.0 – April, 2016 28 CONFIGURATION GUIDE – NEC Express5800/R120g-2E Storage-Rich NIC Teaming feature – NIC Teaming and bonding features See the table below for supported network interfaces and OS combinations. Windows Server 2008 R2 supports BASP (Broadcom Advanced Server Program) or Intel PROSet teaming while Windows Server 2012 (and later) and Linux support teaming with bonding function supported by OS. Network Interface Team Operating Systems 1GbE NIC Embedded/N8104-150/-151/-152 Up to four ports per one team Windows Server 2008 R2 Windows Server 2012 Windows Server 2012 R2 Red Hat Enterprise Linux N8104-145 Up to four ports per one team Windows Server 2008 R2 10GbE NIC (10GBASE-SR) N8104-149 Up to four ports per one team Windows Server 2008 R2 Windows Server 2012 Windows Server 2012 R2 Red Hat Enterprise Linux 10GbE NIC (10GBASE-T) N8104-153/-157 Up to four ports per one team Windows Server 2012 Windows Server 2012 R2 Red Hat Enterprise Linux NOTE: NIC Teaming feature is not supported on iSCSI interfaces. The network interfaces for each team must be the same. When 10GbE NIC teaming and 1GbE NIC teaming are mixed, the teams must be up to five per one system. However, the teams must be up to four per one system when using Windows Server 2008 R2. Using iSCSI See the table below for supported network interfaces and OS combinations. Category Network Interface Operating Systems 1GbE Embedded 1GbE NIC/ N8104-150/-151/-152 Windows Server 2008 R2, Windows Server 2012, Windows Server 2012 R2, Red Hat Enterprise Linux, VMware N8104-145 Windows Server 2008 R2, VMware 10GbE (10GBASE-SR) N8104-149 Windows Server 2008 R2, Windows Server 2012, Windows Server 2012 R2, Red Hat Enterprise Linux, VMware 10GbE (10GBASE-T) N8104-153 Windows Server 2012, Windows Server 2012 R2 Red Hat Enterprise Linux, VMware N8104-157 Windows Server 2012, Windows Server 2012 R2 Red Hat Enterprise Linux NOTE: NIC Teaming feature is not supported on iSCSI interfaces. 7.2 InfiniBand Category Product Name / Description Part Number Controller Single Port InfiniBand Adapter Mellanox ConnectX-3 VPI, MCX353A-FCBT, FDR, PCIe 3.0(x8) Dual Port InfiniBand Adapter Mellanox ConnectX-3 VPI, MCX354A-FCBT, FDR, PCIe 3.0(x8) InfiniBand Cable 2m/FRD Copper N8104-146 Cable NEC Corporation Revision 1.0 – April, 2016 N8104-147 K410-304(02) 29 CONFIGURATION GUIDE – NEC Express5800/R120g-2E Storage-Rich Switch Unit Power Supply InfiniBand Cable 3m/FDR Copper InfiniBand Switch 36 ports/FDR Mellanox MSX6036F-1SFR 36 ports, FDR, One power supply module included, no power cord Redundant Power Supply Unit Power supply module for 36 ports InfiniBand switch, no power cord K410-304(03) NE3707-061 NE3707-063 NOTE: Up to two InfiniBand adapters can be installed into the system and two adapters should be of the same type. The InfiniBand adapters and other options are make-to-order products. Please consult our sales representative in regards to production lead time. 7.3 External Storage Controller 7.3.1 RAID Controller Category Product Name / Description Part Number Controller RAID Controller (2GB, RAID0/1/5/6) LSI MegaRAID SAS 9380-8e RAID0/1/5/6/10/50/60, 2GB, Ext. 8, PCIe 3.0 x8, SAS 12Gb/s, SATA 6Gb/s, Flash cache protection modules included N8103-179 NOTE: To configure a large-capacity RAID array, it is recommended to configure in RAID 6 or RAID 60 in order to minimize the risk of becoming multiple hard drives failure during the RAID rebuilding process. It is recommended to set RAID array configuration drives less than eight in order to minimize the risk of becoming multiple hard drives failure. For VMware ESXi 5.5 and ESXi 6.0, there are some limitations concerning the number of installable PCI cards. Refer to Supported PCI Cards and Installable Slots for details. 7.3.2 Fibre Channel / SAS Controller Category Product Name / Description Part Number Fibre Channel Fibre Channel Controller (1ch) Emulex LightPulse LPe1250-F8 Host Bus Adapter 8Gb/s, Optical, PCIe 2.0 x8 Fibre Channel Controller (2ch) Emulex LightPulse LPe12002-M8 Host Bus Adapter 8Gb/s, Optical, PCIe 2.0 x8 Fibre Channel Controller (1ch) Emulex LightPulse LPe16000B-M6 Host Bus Adapter 16Gb/s, Optical, PCIe 3.0 x8 Fibre Channel Controller (2ch) Emulex LightPulse LPe16002B-M6 Host Bus Adapter 16Gb/s, Optical, PCIe 3.0 x8 SAS Controller LSI SAS9212-4i4e Host Bus Adapter 6Gb/s SAS, Int. 4 / Ext. 4, 7-pin SATA / SFF-8088, PCIe 2.0 x8 SAS Controller LSI SAS9300-8e Host Bus Adapter 12Gb/s SAS, ext. 8(SFF-8644 x2), PCIe 3.0 x8 N8190-159 SAS N8190-160 N8190-157A N8190-158A N8103-142 N8103-184 NOTE: With regard to 16Gb/s Fiber Channel Controllers, up to two ports in a single processor configuration NEC Corporation Revision 1.0 – April, 2016 30 CONFIGURATION GUIDE – NEC Express5800/R120g-2E Storage-Rich with Xeon E5-2603 v4, and up to six ports in a dual processor configuration with Xeon E5-2603 v4 are allowed in the system. Up to three SAS Controllers can be installed. For VMware ESXi 5.5 and ESXi 6.0, there are some limitations concerning the number of installable PCI cards. Refer to Supported PCI Cards and Installable Slots for details. 7.4 Serial Port Adapter Product Name / Description Part Number Serial Port Adapter Serial port fixed to PCI bracket N8117-01A NOTE: Up to one Serial Port Adapter can be installed. NEC Corporation Revision 1.0 – April, 2016 31 CONFIGURATION GUIDE – NEC Express5800/R120g-2E Storage-Rich 8 Other Add-in Components 8.1 Redundant Power Supply Module Product Name / Description Part Number 800W Hot Plug Power Supply 1 x 800 Watt 80 PLUS® Platinum N8181-122F 8.2 Redundant Fan Kit Product Name / Description Part Number Redundant Fan Kit hot plug redundant cooling fans for R120g-2E N8181-126 NOTE: Operable ambient temperature is up to 35°C (95°F) when N8181-126 Redundant Fan Kit is installed and N8150-490/-483/-486/-518 SAS HDD is installed in the rear HDD cage. 8.3 Trusted Platform Module Kit Product Name / Description Part Number Trusted Platform Module Kit TPM 2.0 module N8115-26 NOTE: The kit is not available in China. The kit is not removable after attachment. "TPM Support" in BIOS setup menu must be activated prior to use of this kit. To use Windows BitLocker drive encryption, be sure to keep the "recovery password" of BitLocker function. The recovery password is required to restore data for hardware replacement during a system error. 8.4 Internal Flash Memory Product Name / Description Part Number VMware ESXi support kit Internal USB flash memory to install VMware ESXi system N8106-009 NOTE: The kit does not include VMware ESXi installation media and license. 8.5 Flash FDD Choose the Flash FDD if you need to prepare an alternative device for a floppy drive. Product Name / Description Part Number Flash FDD USB flash emulating USB floppy disk, Native capacity 1.44 MB N8160-96 NOTE: Up to one drive can be connected. NEC Corporation Revision 1.0 – April, 2016 32 CONFIGURATION GUIDE – NEC Express5800/R120g-2E Storage-Rich 9 Add-on Components 9.1 17-inch LCD Console Drawer Category Drawer Drawer w/ KVM Cable Drawer Drawer w/o KVM Keypad Product Name / Description Part Number 17-inch LCD Console Drawer (8port) 17-inch LCD, US 83-keys Keyboard, Optical mouse, 8 port KVM switch, 1U height Switch Unit Connection Cable Set (USB, 1.8m) 1.8 m, 1 x 15-pin mini D-sub to 1 x 15-pin mini D-sub / 1 x 4-pin USB A Switch Unit Connection Cable Set (USB, 3m) 3 m, 1 x 15-pin mini D-sub to 1 x 15-pin mini D-sub / 1 x 4-pin USB A Switch Unit Connection Cable Set (USB, 5m) 5 m, 1 x 15-pin mini D-sub to 1 x 15-pin mini D-sub / 1 x 4-pin USB A 17inch LCD Console Unit 1U 17-inch LCD, US 83-keys Keyboard, Optical mouse, 1U height, 4-pin USB B to 4-pin USB A cable 2 m, PS/2 Y-splitter cable 2m, 15-pin mini D-sub VGA cable 2 m 17inch LCD Console Drawer (1port) 17-inch LCD, US 103-keys Keyboard with 10-key, Touch pad with 3-button, 1U height, 4-pin USB B to 4-pin USB A cable 1.8 m, Two PS/2 cable 1.8 m, 15-pin mini D-sub VGA cable 1.8 m Keyboard Unit (JP) JP 108-keys Keyboard with 10-key for N8143-108F 17inch LCD Console Drawer (1port) Keyboard Unit (UK) UK 104-keys Keyboard with 10-key, for N8143-108F 17inch LCD Console Drawer (1port) N8143-106F K410-118(1A) K410-118(03) K410-118(05) N8143-105F N8143-108F N8143-109 N8143-111 NOTE: There are two VGA connectors on R120g-2E, one on the front side and one on the rear side. However, the front side only works when both are connected at the same time. 9.2 KVM Switch Category Product Name / Description Part Number KVM Switch Server Switch Unit (8 server) 1U USB 8 port KVM switch N8191-14F Switch Unit Connection Cable Set (USB,1.8m) 1.8 m, 1 x 15-pin mini D-sub to 1 x 15-pin mini D-sub / 1 x 4-pin USB A Switch Unit Connection Cable Set (USB,3m) 3 m, 1 x 15-pin mini D-sub to 1 x 15-pin mini D-sub / 1 x 4-pin USB A Switch Unit Connection Cable Set (USB,3m) 5 m, 1 x 15-pin mini D-sub to 1 x 15-pin mini D-sub / 1 x 4-pin USB A Switch Unit Connection Cable 1.8 m 1.8 m, 1 x 15-pin mini D-sub - 1x 15-pin mini D-Sub / 2x PS/2 K410-118(1A) Cable KVM Cascading K410-118(03) K410-118(05) K410-119(1A) NOTE: There are two VGA connectors on R120g-2E, one on the front side and one on the rear side. However, the front side only works when both are connected at the same time. NEC Corporation Revision 1.0 – April, 2016 33 CONFIGURATION GUIDE – NEC Express5800/R120g-2E Storage-Rich 9.3 Cable Management Arm Product Name / Description Part Number Cable Management Arm 2U Kit for R120g-2E N8143-95 9.4 Server Management License The server integrates the EXPRESSSCOPE Engine 3 as standard. Refer to Server Management for the standard management features. For more extensive remote KVM and remote media features, choose the following kit. Product Name / Description Part Number Remote KVM and Media License Kit N8115-04 License for one server. Remote KVM and remote media are enabled regardless of OS status. Remote KVM: Displays a graphics console on the web browser of the remote terminal (PC/server). Controls keyboard and mouse via the remote terminals' web browser Remote media: - Enables the user to use the CD / DVD / FD / Flash memory of the remote terminals (PC/server) as if accessing the local drives. NOTE: Remote KVM and remote media features are not available for virtual machines. NEC Corporation Revision 1.0 – April, 2016 34 CONFIGURATION GUIDE – NEC Express5800/R120g-2E Storage-Rich References Boot Mode Setting The server supports Legacy mode and UEFI mode (default) as an OS Boot Mode. See the table below for the Boot Mode and X2APIC setting for each Operating System. As the default settings at the factory, UEFI mode is set as OS Boot mode and X2APIC is enabled. Refer to the User’s Guide and change the settings before installing an Operating System requiring Legacy Mode. Operating System Supported Boot Mode Supported X2APIC Setting Windows Server 2008 R2 (x64) Legacy Disabled Windows Server 2012 UEFI Enabled Windows Server 2012 R2 UEFI Enabled Red Hat Enterprise Linux 6(x86_64) UEFI Enabled Red Hat Enterprise Linux 7 UEFI Enabled VMware ESXi 5.5 Update3 Legacy Disabled VMware ESXi 6.0 Update 1 Legacy Disabled NEC Corporation Revision 1.0 – April, 2016 35 CONFIGURATION GUIDE – NEC Express5800/R120g-2E Storage-Rich Server Management The EXPRESSSCOPE Engine 3, integrated into the server, provides superior remote control and system management features listed in the table below. Standard Hardware monitoring With Remote KVM and Media License kit Temperature/voltage/power/RAID/ standard LANfan /degeneration (memory/hard drive) Hardware configuration information collection Hardware event log collection 1 1 Boot monitoring BIOS/POST stall, Booting, OS stall, shutdown Alerting HW error, Boot error , and OS panic (by SNMP, E-Mail) Remote KVM (via LAN) POST/BIOS setup, ROM utility Panic screen, Boot screen 2, 3, 4 CUI-based screen (OS console) 2, 4 GUI-based screen (OS console) - Remote console recording function - Manual Video recording - Automatic video recording - 1 Remote reset/power on-off/ dump Remote power capping BIOS/BMC FW update Remote BIOS setup(partial configuration only) Remote control (via LAN) 2 1 1 OS shutdown Remote media (CD/DVD/FD/USB) - CLP (Command Line Protocol) (DMTF compliant) Remote control via Web browser (multi user login at the same time) Scheduling (without UPS) BIOS setting by using XML file Maintenance EXPRESSSCOPE® Profile key (Backup/restore BIOS/BMC setup information) Others Set automatic IP address via DNS/DHCP LDAP/Active Directory verification/user control Clock synchronization of main unit and the RTC Access log collection IPMI 2.0 2.0 IPv6(Web console/CLP only) 1 2 3 4 1 1 The feature is not supported on VMware ESXi systems. The optional serial port is not available for the feature. Monitoring boot screens is not supported on VMware systems. In VMware systems, only the direct console user interface is supported. NEC Corporation Revision 1.0 – April, 2016 36 CONFIGURATION GUIDE – NEC Express5800/R120g-2E Storage-Rich Endurance of SSD The 2.5-inch SAS/SATA SSDs have limited lifetime, which can only be written a limited number of times before it fails. The warranty period of SSD is the stated period of warranty or until the total bytes of written value (PBW) exceeds the limit value, whichever occurs first. It is recommended to check the total bytes of written value periodically. Refer to the table below for the write endurance (PBW and DWPD), warranty period and monitoring tool. SSD Lifetime Part Number Product Name PBW DWPD Period Monitoring Tool N8150-721 200GB Hot Plug 2.5-inch SAS SSD 3.6PBW 10 Times 3 Years N8150-722 400GB Hot Plug 2.5-inch SAS SSD 7.3PBW 10 Times 3 Years Universal RAID Utility, EXPRESSBUILDER (System Test and Diagnostics) SAS SSD SATA SSD (Middle Endurance) N8150-725 200GB Hot Plug 2.5-inch SATA SSD 3.6PBW 10 Times 3 Years N8150-726 400GB Hot Plug 2.5-inch SATA SSD 7.3PBW 10 Times 3 Years N8150-727 800GB Hot Plug 2.5-inch SATA SSD 14.6PBW 10 Times 3 Years SATA SSD (Value Endurance) N8150-732 200GB Hot Plug 2.5-inch SATA SSD 1.1PBW 3 Times 3 Years N8150-733 400GB Hot Plug 2.5-inch SATA SSD 3.0PBW 3 Times 3 Years N8150-734 800GB Hot Plug 2.5-inch SATA SSD 5.3PBW 3 Times 3 Years N8150-735 1.6TB Hot Plug 2.5-inch SATA SSD 10.7PBW 3 Times 3 Years PBW(Peta-Bytes Write): Total amount of data that can be written into the SSD. 1PB=1,000TB. DWPD(Drive Writes per Day): Rewrite capacity of the SSD per day. Check the lifetime of SSD by monitoring tool regularly. It is recommended to replace the SSD before it reaches its end of life. For repurchase, please contact your sales representative. For detailed operating methods of monitoring tool, refer to the User’s Guide. NEC Corporation Revision 1.0 – April, 2016 37 CONFIGURATION GUIDE – NEC Express5800/R120g-2E Storage-Rich OS Support Matrix for PCI Cards and Embedded Controller ESXi 5.5 ESXi 6.0 RHEL 6 x64 RHEL 7 WS 2008 R2 WS 2012 WS 2012 R2 Part number Product Name - Embedded SATA non-RAID Controller - Embedded SATA RAID Controller - - Embedded 1GbE NIC N8103-176 RAID Controller (1 GB, RAID 0/1) N8103-177 RAID Controller (1 GB, RAID 0/1/5/6) N8103-178 RAID Controller (2 GB,RAID 0/1/5/6) N8103-179 RAID Controller (2 GB,RAID 0/1/5/6) N8118-303 2.5-inch PCIeSSD Installation Kit - - N8190-158A Fibre Channel Controller (2ch) N8190-157A Fibre Channel Controller N8104-147 Dual Port InfiniBand Adapter - - - N8104-146 Single Port InfiniBand Adapter - - - N8104-157 Dual Port 10GBASE-T Adapter - - - N8103-184 SAS Controller - N8190-160 Fibre Channel Controller (2ch) N8190-159 Fibre Channel Controller N8104-153 Dual Port 10GBASE-T Adapter - N8104-149 10GBASE SFP+ Adapter (SFP+/2ch) N8103-142 SAS Controller N8104-152 Quad Port 1000BASE-T Adapter N8104-145 Dual Port 1000BASE-T Adapter --- N8104-151 Dual Port 1000BASE-T Adapter N8104-150 1000BASE-T Adapter NEC Corporation Revision 1.0 – April, 2016 - - - - - 38 CONFIGURATION GUIDE – NEC Express5800/R120g-2E Storage-Rich Supported PCI Cards and Installable Slots Slots #1 1 Prio rity Part Number (1) N8103-176 RAID Controller (1 GB, RAID 0/1) (4) (2) (1) (3) - (2) N8103-177 RAID Controller (1 GB, RAID 0/1/5/6) (4) (2) (1) (3) - (3) N8103-178 RAID Controller (2 GB,RAID 0/1/5/6) (4) (2) (1) (3) - (4) N8103-179 RAID Controller (2 GB,RAID 0/1/5/6) (4) (2) (1) (3) - (5) N8118-303 2.5-inch PCIeSSD Installation Kit - - - (2) - (6) N8190-158A Fibre Channel Controller (2ch) (4) (2) (1) (3) - (7) N8190-157A Fibre Channel Controller (4) (2) (1) (3) - (8) N8104-147 Dual Port InfiniBand Adapter (4) (2) (1) (3) - (9) N8104-146 Single Port InfiniBand Adapter (4) (2) (1) (3) - (10) N8104-157 Dual Port 10GBASE-T Adapter (4) (2) (1) (3) - (11) N8103-184 SAS Controller (4) (2) (1) (3) - (12) N8190-160 Fibre Channel Controller (2ch) (4) (2) (1) (3) - (13) N8190-159 Fibre Channel Controller (4) (2) (1) (3) - (14) N8104-153 Dual Port 10GBASE-T Adapter (4) (2) (1) (3) (5) (15) N8104-149 10GBASE SFP+ Adapter (SFP+/2ch) (4) (2) (1) (3) (5) (16) N8103-142 SAS Controller (4) (2) (1) (3) (5) (17) N8104-152 Quad Port 1000BASE-T Adapter (4) (2) (1) (3) (5) (18) N8104-145 Dual Port 1000BASE-T Adapter (4) (2) (1) (3) (5) (19) N8104-151 Dual Port 1000BASE-T Adapter (4) (2) (1) (3) (5) (20) N8104-150 1000BASE-T Adapter (4) (2) (1) (3) (5) (21) N8117-01A Serial Port Adapter - - (1) (2) (3) 1 Product Name #2 #3 #4 #5 The slot #1 is not available when a single processor configuration. NOTE: The number between parentheses shows the population priority (recommendation). For example, install N8103-176 (1) in the slot #3, N8190-160 (12) in the slot #2 and N8104-153 (14) in the slot #4 when you have those cards. For VMware ESXi 5.5, there are some limitations as follows: - When any of N8104-149/-153/-157 is installed, N8104-152 cannot be installed and the number of installable N8104-150/-151 is limited up to one. - Up to two cards of N8104-152 can be installed. - Up to four cards of N8104-150/-151 can be installed. - Up to three cards of N8104-149/-153/-157 can be installed. - Up to four cards of N8190-158A/N8190-160/N8103-184 can be installed. - When the above four groups are mixed (N8104-152, N8104-150/-151, N8104-149/-153/-157, and N8190-158A/N8190-160/N8103-184), the number of installable cards among them becomes up to three. - When configured with Xeon E5-2660 v4/2690 v4, up to one card of N8103-176/-177/-178/-179 can be installed - When configured with Xeon E5-2650 v4, up to two cards of N8103-176/-177/-178/-179 can be installed For VMware ESXi 6.0, there are some limitations as follows: - When any of N8104-149/-153/-157 is installed, N8104-152 cannot be installed and the number of installable N8104-150/-151 is limited up to one. For the configuration limitation for VMware ESXi, refer to the following documents. VMware ESXi5.5 https://www.vmware.com/pdf/vsphere5/r55/vsphere-55-configuration-maximums.pdf NEC Corporation Revision 1.0 – April, 2016 39 CONFIGURATION GUIDE – NEC Express5800/R120g-2E Storage-Rich VMware ESXi6.0 https://www.vmware.com/pdf/vsphere6/r60/vsphere-60-configuration-maximums.pdf Copyright Notice and Liability Disclaimer The information contained herein is subject to change without notice. Microsoft and Windows Server are either registered trademarks or trademarks of Microsoft Corporation in the United States and/or other countries Intel and Xeon are registered trademarks or trademarks of Intel Corporation or its subsidiaries in the United States and other countries. Linux is a trademark of Linus Torvalds. Red Hat is a registered trademark of Red Hat, Inc. in the U.S. All other products, brands, or trade names used in this document are trademarks or registered trademarks of their respective holders. NEC shall not be liable for technical or editorial errors or omissions contained herein. For hard drive capacity measurements, 1 GB = 1 billion bytes. Actual formatted capacity is less. NEC Corporation Revision 1.0 – April, 2016 40 CONFIGURATION GUIDE – NEC Express5800/R120g-2E Storage-Rich Revision History Revision Date Description 1.0 April 25, 2016 Initial release NEC Corporation Revision 1.0 – April, 2016 41