NEC Express5800/T120g System Configuration Guide Introduction This document contains product and configuration information that will enable you to configure your system. The guide will ensure fast and proper configuration of your NEC Express5800 server. May 17, 2016 Revision 1.1 NEC Corporation SYSTEM CONFIGURATION GUIDE – NEC Express5800/T120g Contents TECHNICAL SPECIFICATION ........................................................................................ 3 Key Features .......................................................................................................................................... 3 Specification .......................................................................................................................................... 3 EXTERNAL VIEWS ......................................................................................................... 7 Front and Rear Views ........................................................................................................................... 7 Dimensions (mm) .................................................................................................................................. 9 CONFIGURATION DIAGRAM ....................................................................................... 10 EXPANSION SLOTS ..................................................................................................... 10 SERVER CONFIGURATION ......................................................................................... 11 1 2 3 4 5 6 7 8 9 Base Models ................................................................................................................................. 11 Processors and Heat Sink .......................................................................................................... 11 Memory ......................................................................................................................................... 12 3.1 Memory Configuration ......................................................................................................... 12 Internal Hard Disk Drives ............................................................................................................ 15 4.1 RAID Configuration .............................................................................................................. 15 4.2 Required Components for RAID Configuration ................................................................... 16 4.3 Supported Drives ................................................................................................................. 20 Optical Drive ................................................................................................................................. 25 Internal Tape / RDX Drives .......................................................................................................... 25 6.1 Tape / RDX Drive Selection ................................................................................................. 25 6.2 Tape / RDX Configuration .................................................................................................... 25 PCI Card ........................................................................................................................................ 26 7.1 Graphics Card Installation Kit .............................................................................................. 26 7.2 Network Interface Controller ................................................................................................ 26 7.3 External Storage Controller ................................................................................................. 28 7.4 Serial Port Adapter .............................................................................................................. 29 Other Add-in Components .......................................................................................................... 29 8.1 Redundant Fan .................................................................................................................... 29 8.2 Trusted Platform Module Kit ................................................................................................ 29 8.3 Internal Flash Memory ......................................................................................................... 30 8.4 High Temperature Support Option ....................................................................................... 30 8.5 Flash FDD............................................................................................................................ 30 Add-on Components ................................................................................................................... 31 9.1 Input Devices ....................................................................................................................... 31 9.2 Server Management License............................................................................................... 31 9.3 Rack Conversion Kit ............................................................................................................ 31 9.4 Dust / Insect Proof Kit .......................................................................................................... 31 9.5 Medium and Cartridge ......................................................................................................... 32 REFERENCES............................................................................................................... 33 Boot Mode Setting .............................................................................................................................. 33 Server Management ............................................................................................................................ 34 Endurance of SSD ............................................................................................................................... 35 OS Support Matrix for PCI Cards and Embedded Controllers ....................................................... 36 Supported PCI Cards and Installable Slots ...................................................................................... 37 Copyright Notice and Liability Disclaimer ........................................................................................ 38 NEC Corporation Revision 1.1 – May, 2016 2 SYSTEM CONFIGURATION GUIDE – NEC Express5800/T120g REVISION HISTORY ..................................................................................................... 39 Technical Specification Key Features High performance with the latest Intel® Xeon® processor E5-2600 v4 product family Up to 512 GB of high speed DDR4 memory High energy efficiency with power capping feature and 80 PLUS® Platinum or Gold power supply Full manageability by integrated EXPRESSSCOPE Engine 3 Specification (1/2) Model T120g Part Number N8100-2476F, N8100-2477F, N8100-2478F, N8100-2479F Processor Type Intel® Xeon® Processor E5-2603 v4 Intel® Xeon® Processor E5-2620 v4 Intel® Xeon® Processor E5-2623 v4 Intel® Xeon® Processor E5-2630 v4 Clock speed 1.70 GHz 2.10 GHz 2.60 GHz 2.20 GHz Number of Processors 1 or 2 Cache 15 MB 20 MB 10 MB 25 MB Cores and Threads 6C - 6T 8C - 16T 4C - 8T 10C - 20T Chipset Memory Internal Storage NEC Corporation Intel® C612 Chipset Type DDR4-2400 Registered DIMM (4/8/16/32GB) Standard Capacity 0 GB Maximum Capacity 512 GB (16 x 32 GB) Memory protection ECC, x4 SDDC, Memory Mirroring, Memory Lockstep, Memory Sparing Standard Capacity 0 GB Maximum Capacity Hot plug 2.5-inch drive configuration: SAS HDD: 43.2 TB (24 x 1.8 TB) SATA HDD: 48 TB (24 x 2 TB) SAS SSD : 9.6 TB ( 24 x 400 GB) SATA SSD : 38.4 TB ( 24 x 1.6 TB) Hot plug 3.5-inch drive configuration: SATA HDD: 48 TB (8 x 6 TB) Storage Controller SATA : 6 Gb/s (Integrated) SAS: 12 Gb/s (Optional) RAID SATA : RAID 0/1/10 (Standard), RAID 5/6/50/60 (Optional) SAS : RAID 0/1/5/6/10/50/60 (Optional) Hot Plug Supported Optical Disk Drive Optional 5-inch Media Bays 2 Disk Drive Bays Hot plug 2.5-inch drive configuration: 24 Hot plug 3.5-inch drive configuration: 8 1 Revision 1.1 – May, 2016 3 SYSTEM CONFIGURATION GUIDE – NEC Express5800/T120g Model T120g Expansion Slots Total: 5 slots available 2 PCIe 3.0 x16 (x16 connector) 1 PCIe 3.0 x8 (x8 connector) 1 PCIe 3.0 x8 (x8 connector) (Dual processor configuration only) 1 PCIe 2.0 x4 (x8 connector) Video Controller (VRAM) Integrated in Server Management Controller (32MB) Resolution / Color 1600 x 1200 / 16.7M 2 Interfaces 5 USB3.0 (2 x front, 4 x rear, 1 x internal) 3 USB2.0 (2 x front, 1 x internal) 1 VGA (15-pin mini D-sub, 1 x rear) 1 to 2 Serial (9-pin mini D-sub, RS232-C, 1 to 2 x rear) 2 1000BASE-T LAN connector (RJ-45, 2 x rear) 1 Management LAN connector (RJ-45, 1 x rear) Server Management EXPRESSSCOPE Engine 3 Redundant Fan Optional, hot plug with redundant fan kit Redundant Power Supply Standard, hot plug (except non-redundant power supply model) Power Supply 2 x 460 / 800 / 1000 Watt 80 PLUS® Platinum certified hot plug PSU 1 x 700 Watt 80 PLUS® Gold certified non-hot plug PSU 100-240 VAC ± 10% 50 / 60 Hz ± 3 Hz Power Consumption (Max. Config, Idling) 320 VA / 317 Watt 321 VA / 318 Watt 318 VA / 316 Watt 321 VA / 319 Watt (Max. Config, Operating) 613 VA / 609 Watt 622 VA / 617 Watt 671 VA / 667 Watt 720 VA / 715 Watt Acoustical Noise Max. Config, Idling (Sound Pressure Max. Config, Operating 3 Level) Dimensions (W x D x H ) 40.0 dB Weight (Minimum / Maximum) 17 kg / 31.0 kg, 37.47 lbs. / 68.34 lbs. Temperature, Relative Humidity (non-condensing) Operating: 5° to 40° C / 41° to 104° F (Standard) or 5° to 45° C / 41° to 113° F (Optional), 20 to 80% Non-Operating: -10° to 55° C / 14° to 131° F, 20 to 80% Regulatory and Safety FCC, UL, CB, CE, BSMI, CCC, RoHS, WEEE Operating Systems and Virtualization Software Microsoft® Windows Server® 2008 R2 Standard Microsoft® Windows Server® 2008 R2 Enterprise Microsoft® Windows Server® 2012 Standard Microsoft® Windows Server® 2012 Datacenter Microsoft® Windows Server® 2012 R2 Standard Microsoft® Windows Server® 2012 R2 Datacenter 4 Red Hat Enterprise Linux 6.7 or later (x86_64) 4 Red Hat Enterprise Linux 7.2 or later VMware ESXi™ 5.5 Update 3 VMware ESXi™ 6.0 Update 1 1 2 3 4 44.0 dB 200.0 x 599.0 x 438.0 mm / 7.8 x 23.5 x 17.2 in (5U) Embedded SATA RAID controller is supported only on limited operating systems. Maximum resolution available via EXPRESSSCOPE Engine 3 remote console is 1280 x 1024 / 65K colors. Noise emission was measured at the operator positions in accordance with ISO 7779. The actual value may vary by the operating environment. For Linux support, contact your sales representative or visit the NEC website at: http://www.nec.com/en/global/prod/express/linux/index.html NEC Corporation Revision 1.1 – May, 2016 4 SYSTEM CONFIGURATION GUIDE – NEC Express5800/T120g (2/2) Model T120g Part Number N8100-2476F, N8100-2477F, N8100-2478F, N8100-2479F Processor Type Intel® Xeon® Processor E5-2650 v4 Intel® Xeon® Processor E5-2660 v4 Intel® Xeon® Processor E5-2690 v4 Intel® Xeon® Processor E5-2697 v4 Clock speed 2.20 GHz 2.00 GHz 2.60 GHz 2.30 GHz Number of Processors 1 or 2 Cache 30 MB 35 MB 45 MB Cores and Threads 12C - 24T 14C - 28T 18C - 36T Chipset Memory Internal Storage Intel® C612 Chipset Type DDR4-2400 Registered DIMM (4/8/16/32GB) Standard Capacity 0 GB Maximum Capacity 512 GB (16 x 32 GB) Memory protection ECC, x4 SDDC, Memory Mirroring, Memory Lockstep, Memory Sparing Standard Capacity 0 GB Maximum Capacity Hot plug 2.5-inch drive configuration: SAS HDD: 43.2 TB (24 x 1.8 TB) SATA HDD: 48 TB (24 x 2 TB) SAS SSD : 9.6 TB ( 24 x 400 GB) SATA SSD : 38.4 TB ( 24 x 1.6 TB) Hot plug 3.5-inch drive configuration: SATA HDD: 48 TB (8 x 6 TB) Storage Controller SATA : 6 Gb/s (Integrated) SAS: 12 Gb/s (Optional) RAID SATA : RAID 0/1/10 (Standard), RAID 5/6/50/60 (Optional) SAS : RAID 0/1/5/6/10/50/60 (Optional) Hot Plug Supported Optical Disk Drive Optional 5-inch Media Bays 2 Disk Drive Bays Hot plug 2.5-inch drive configuration: 24 Hot plug 3.5-inch drive configuration: 8 1 Expansion Slots Video Total: 5 slots available 2 PCIe 3.0 x16 (x16 connector) 1 PCIe 3.0 x8 (x8 connector) 1 PCIe 3.0 x8 (x8 connector) (Dual processor configuration only) 1 PCIe 2.0 x4 (x8 connector) Controller (VRAM) Integrated in Server Management Controller (32MB) Resolution / Color 1280 x 1024 / 16.7M 2 Interfaces 5 USB3.0 (2 x front, 4 x rear, 1 x internal) 3 USB2.0 (2 x front, 1 x internal) 1 VGA (15-pin mini D-sub, 1 x rear) 1 to 2 Serial (9-pin mini D-sub, RS232-C, 1 to 2 x rear) 2 1000BASE-T LAN connector (RJ-45, 2 x rear) 1 Management LAN connector (RJ-45, 1 x rear) Server Management EXPRESSSCOPE Engine 3 Redundant Fan Optional, hot plug with redundant fan kit Redundant Power Supply Standard, hot plug (except non-redundant power supply model) NEC Corporation Revision 1.1 – May, 2016 5 SYSTEM CONFIGURATION GUIDE – NEC Express5800/T120g Model T120g Power Supply 2 x 460 / 800 / 1000 Watt 80 PLUS® Platinum certified hot plug PSU 1 x 700 Watt 80 PLUS® Gold certified non-hot plug PSU 100-240 VAC ± 10% 50 / 60 Hz ± 3 Hz Power Consumption (Max. Config, Idling) 322 VA / 320 Watt 322 VA / 320 Watt (Max. Config, Operating) 766 VA / 761 Watt 846 VA / 840 Watt Acoustical Noise Max. Config, Idling (Sound Pressure Max. Config, Operating 3 Level) Dimensions (W x D x H ) 40.0 dB 40.0 dB 45.0 dB 44.0 dB Weight (Minimum / Maximum) 17 kg / 31.0 kg, 37.47 lbs. / 68.34 lbs. Temperature, Relative Humidity (non-condensing) Operating: 5° to 40° C / 41° to 104° F (Standard) or 5° to 45° C / 41° to 113° F (Optional), 20 to 80% Non-Operating: -10° to 55° C / 14° to 131° F, 20 to 80% Regulatory and Safety FCC, UL, CB, CE, BSMI, CCC, RoHS, WEEE Operating Systems and Virtualization Software Microsoft® Windows Server® 2008 R2 Standard Microsoft® Windows Server® 2008 R2 Enterprise Microsoft® Windows Server® 2012 Standard Microsoft® Windows Server® 2012 Datacenter Microsoft® Windows Server® 2012 R2 Standard Microsoft® Windows Server® 2012 R2 Datacenter 4 Red Hat Enterprise Linux 6.7 or later (x86_64) 4 Red Hat Enterprise Linux 7.2 or later VMware ESXi™ 5.5 Update 3 VMware ESXi™ 6.0 Update 1 1 2 3 4 200.0 x 599.0 x 438.0 mm / 7.8 x 23.5 x 17.2 in (5U) Embedded SATA RAID controller is supported only on limited operating systems. Maximum resolution available via EXPRESSSCOPE Engine 3 remote console is 1280 x 1024 / 65K colors. Noise emission was measured at the operator positions in accordance with ISO 7779. The actual value may vary by the operating environment. For Linux support, contact your sales representative or visit the NEC website at: http://www.nec.com/en/global/prod/express/linux/index.html NEC Corporation Revision 1.1 – May, 2016 6 SYSTEM CONFIGURATION GUIDE – NEC Express5800/T120g External Views Front and Rear Views Front View (with front bezel) A I J H B C D E F G I J Legend A. Power Button F. Data LAN 1 Activity LED B. Power LED G. Data LAN 2 Activity LED C. System Status LED 1 H. Front Bezel Key D. System Status LED 2 I. Front Bezel E. Power Capping LED J. Stabilizer NEC Corporation Revision 1.1 – May, 2016 7 SYSTEM CONFIGURATION GUIDE – NEC Express5800/T120g Front View (without front bezel) A E F G B C H D Hot Plug 2.5-inch Drive Configuration Hot Plug 3.5-inch Drive Configuration Legend A. 5.25-inch Media Bay B. E. System Reset Button Optical Drive Bay F. Dump (NMI) Button C. USB Connectors G. BMC Reset Button D. 2.5-inch Drive Bay H. 3.5-inch Drive Bay Rear View A A B B D E F G I H C Non-hot Plug Power Supply Configuration Hot Plug Power Supply Configuration Legend A. B. Power Supply Unit F. UID Button/LED Management LAN Connector AC Inlet G. C. PCI Slots H. USB Connectors D. Serial Port Connector I. Data LAN Connectors E. VGA Connector NEC Corporation Revision 1.1 – May, 2016 8 SYSTEM CONFIGURATION GUIDE – NEC Express5800/T120g Dimensions (mm) Non-hot Plug Power Supply Configuration 611 200 438 599 313.4 Hot Plug Power Supply Configuration 625.4 200 438 599 NEC Corporation Revision 1.1 – May, 2016 313.4 9 SYSTEM CONFIGURATION GUIDE – NEC Express5800/T120g Configuration Diagram CHASSIS REAR CHASSIS INSIDE Power Supply CHASSIS FRONT Cooling Fan* Power Supply Cooling Fan 4x DIMM Slots 4x DIMM Slots Cooling Fan 1x DIMM 4x DIMM Slots Optical Drive Bay Drive Cage Bay Drives 4 Flash Back up Unit Slots PCIe Gen3 PCI 4 PCI 5 Optical Drive Bay CPU 1 PCI 1 PCI 3 2x Media Bay CPU 2 4x DIMM Slots PCI 2 2x Media Bay PCIe Gen2 Legend: Standard Components Mandatory Components Expansion Slots Slot #1 Slot #2 Slot #3 Slot #4 Slot #5 Legend #1 PCIe 3.0 x8, x8 connector, Full height, up to 168 mm length #2 PCIe 3.0 x16, x16 connector, Full height, up to 290 mm length #3 PCIe 3.0 x8, x8 connector, Full height, up to 290 mm length #4 PCIe 3.0 x16, x16 connector, Full height, up to 290 mm length #5 PCIe 2.0 x4, x8 connector, Full height, up to 168 mm length NOTE: The slot #1 is available in dual processor configuration. NEC Corporation Revision 1.1 – May, 2016 10 SYSTEM CONFIGURATION GUIDE – NEC Express5800/T120g Server Configuration 1 Base Models Product Name / Description Part Number EXPRESS5800/T120g Server no processor, no RAM, no Drive Cage, no HDD, no DVD, no FAN, no keyboard, no mouse Including: 700W 80 PLUS® Gold non-hot plug PSU EXPRESS5800/T120g Server no processor, no RAM, no Drive Cage, no HDD, no DVD, no FAN, no keyboard, no mouse Including: 2 x 460W 80 PLUS® Platinum hot plug PSU EXPRESS5800/T120g Server no processor, no RAM, no Drive Cage, no HDD, no DVD, no FAN, no keyboard, no mouse Including: 2 x 800W 80 PLUS® Platinum hot plug PSU EXPRESS5800/T120g Server no processor, no RAM, no Drive Cage, no HDD, no DVD, no FAN, no keyboard, no mouse Including: 2 x 1000W 80 PLUS® Platinum hot plug PSU N8100-2476F N8100-2477F N8100-2478F N8100-2479F NOTE: The base model must be ordered with a processor kit and memory, a drive cage. Keyboard and mouse are not included in the base models. Please order separately if necessary. Use the NEC Power Supply Selector to select appropriate size for power units. For details, please visit the NEC website at: http://www.nec.com/en/global/prod/express/collateral/tools/PowerSelector_G01.xls 2 Processors and Heat Sink Available sockets: 2 Category Product Name / Description Part Number Processors 1 Processor Required Xeon E5-2603 v4 Processor Kit Intel® Xeon ® Processor E5-2603 v4 (1.70 GHz, 6C/6T, 15 MB) Xeon E5-2620 v4 Processor Kit Intel® Xeon ® Processor E5-2620 v4 (2.10 GHz, 8C/16T, 20 MB) Xeon E5-2623 v4 Processor Kit Intel® Xeon ® Processor E5-2623 v4 (2.60 GHz, 4C/8T, 10 MB) Xeon E5-2630 v4 Processor Kit Intel® Xeon ® Processor E5-2630 v4 (2.20 GHz, 10C/20T, 25 MB) Xeon E5-2650 v4 Processor Kit Intel® Xeon ® Processor E5-2650 v4 (2.20 GHz, 12C/24T, 30 MB) Xeon E5-2660 v4 Processor Kit Intel® Xeon ® Processor E5-2660 v4 (2.00 GHz, 14C/28T, 35 MB) Xeon E5-2690 v4 Processor Kit Intel® Xeon ® Processor E5-2690 v4 (2.60 GHz, 14C/28T, 35 MB) Xeon E5-2697 v4 Processor Kit Intel® Xeon ® Processor E5-2697 v4 (2.30 GHz, 18C/36T, 45 MB) Processor Heat Sink st For 1 Processor N8101-1068F Processor Heat Sink nd For 2 Processor N8101-928F Heat Sink 1st 2nd N8101-1070F N8101-1071F N8101-1072F N8101-1073F N8101-1074F N8101-1075F N8101-1076F (Standard) NOTE: Minimum one processor kit from above must be installed. NEC Corporation Revision 1.1 – May, 2016 11 SYSTEM CONFIGURATION GUIDE – NEC Express5800/T120g The processors must be the same to configure dual processor system. The maximum number of logical processors supported by OS See the table below for the maximum number of logical processors that you can actually use on your system. Number of Logical Processors Supported by Operating Systems Maximum Available Number of Logical Processors Microsoft Windows Server 2008 R2 Standard (x64) Microsoft Windows Server 2008 R2 Enterprise (x64) 256 1 72 Microsoft Windows Server 2012 Standard Microsoft Windows Server 2012 Datacenter Microsoft Windows Server 2012 R2 Standard Microsoft Windows Server 2012 R2 Datacenter 640 1 72 Red Hat Enterprise Linux 6 (x86_64) Red Hat Enterprise Linux 7 240 72 VMware ESXi 5.5 320 72 VMware ESXi 6.0 480 72 1 The maximum numbers of logical processors when using Hyper-V are below : - Windows Server 2008 R2 : 64 - Windows Server 2012 and Windows Server 2012 R2 : 320 3 Memory 3.1 Memory Configuration Refer to the section in accordance with your operating system and memory configuration: Independent channel / Memory Sparing Configuration: Refer to 3.1.1 Memory Sparing Configuration: Refer to 3.1.2 Memory Mirroring / Memory Lockstep Configuration: Refer to 3.1.3 Memory Configuration Feature Comparison See the table below for feature comparisons of memory configurations supported. Independent Channel Memory Sparing Memory Lockstep Memory Mirroring Performance Best Better Better Good Data Protection No Multiple single bit error protection No Multiple single bit and multi bit error protection Redundancy No Partly No Fully Data Correction ECC, x4 SDDC ECC, x4 SDDC ECC, x8 SDDC ECC, x4 SDDC Available Memory Full physical memory 3/4 physical memory Full physical memory Half physical memory Available Memory Channels Notes 4 4 4 4 - All DIMMs in the system must be identical. Paired DIMMs must be identical. Paired DIMMs must be identical. NEC Corporation Revision 1.1 – May, 2016 12 SYSTEM CONFIGURATION GUIDE – NEC Express5800/T120g 3.1.1 Independent Channel Configuration Available slots: 8 per processor Category Product Name / Description Part Number Registered DIMM (RDIMM) 4GB DDR4-2400 REG Memory Kit (1x4GB) 1x 4GB Registered ECC DIMM, DDR4-2400(PC4-2400) 8GB DDR4-2400 REG Memory Kit (1x8GB) 1x 8GB Registered ECC DIMM, DDR4-2400(PC4-2400) 16GB DDR4-2400 REG Memory Kit (1x16GB) 1x 16GB Registered ECC DIMM, DDR4-2400(PC4-2400) 32GB DDR4-2400 REG Memory Kit (1x32GB) 1x 32GB Registered ECC DIMM, DDR4-2400(PC4-2400) N8102-686F N8102-687F N8102-688F N8102-689F NOTE: Minimum one memory kit per processor must be installed. It is recommended to install memory kits in multiples of four identical DIMMs for quad-channel symmetric memory configurations to increase memory transfer speed. When two processors are installed, balance the DIMMs across the two processors. At least 5 GB of memory is required for VMware ESXi™ 5.5 and ESXi™ 6.0 3.1.2 Memory Sparing Configuration Available slots: 8 per processor Product Name / Description Part Number 16GB DDR4-2400 REG Memory Kit (2x8GB) 2x 8GB Registered ECC DIMM, DDR4-2400(PC4-2400) 32GB DDR4-2400 REG Memory Kit (2x16GB) 2x 16GB Registered ECC DIMM, DDR4-2400(PC4-2400) N8102-693 N8102-694 NOTE: Minimum one memory kit per processor must be installed. The memory kits must be identical. The logical memory capacity at the time of memory sparing becomes three-fourths of physical capacity. 3.1.3 Memory Mirroring / Memory Lockstep Configuration Available slots: 8 per processor Product Name / Description Part Number 16GB DDR4-2400 REG Memory Kit (2x 8GB) 2x 8GB Registered ECC DIMM, DDR4-2400(PC4-2400) 32GB DDR4-2400 REG Memory Kit (2x 16GB) 2x 16GB Registered ECC DIMM, DDR4-2400(PC4-2400) N8102-691 N8102-692 NOTE: Minimum one memory kit per processor must be installed. The logical memory capacity at the time of memory mirroring becomes a half of physical capacity. NEC Corporation Revision 1.1 – May, 2016 13 SYSTEM CONFIGURATION GUIDE – NEC Express5800/T120g Maximum Memory Speed See the table below for the actual maximum memory transfer speed in Independent Channel / Memory Sparing Configuration. DDR4 memory speed depends on the type of DIMMs, the native memory bus speed of the memory controller and memory configuration. All memory buses operate at the clock frequency of the DIMM with the lowest frequency. Processor Type Populated DIMMs Memory Power Setting DIMM Speed E5-2603 v4 4 GB, 8 GB,16 GB, 32GB - 1866 MHz E5-2620 v4 E5-2623 v4 E5-2630 v4 4 GB, 8 GB,16 GB, 32GB - 2133 MHz E5-2650 v4 E5-2660 v4 E5-2690 v4 E5-2697 v4 4 GB, 8 GB,16 GB, 32GB - 2400 MHz Maximum Available Memory See the table below for the maximum memory size that you can actually use on your system. Maximum Memory Size Supported by Operating Systems 1 32 GB 32 GB 2 TB 512 GB 4 TB 512 GB Red Hat Enterprise Linux 6 (x86_64) Red Hat Enterprise Linux 7 6 TB 512 GB VMware ESXi 5.5 2 4 TB 512 GB VMware ESXi 6.0 3 6 TB 512 GB Microsoft Windows Server 2008 R2 Standard Microsoft Windows Server 2008 R2 Enterprise 1 1 Microsoft Windows Server 2012 Standard 1 Microsoft Windows Server 2012 Datacenter 1 Microsoft Windows Server 2012 R2 Standard Microsoft Windows Server 2012 R2 Datacenter 1 2 3 Maximum Available Memory 1 The maximum available memory size of Hyper-V systems are below: - Windows Server 2008 R2 Standard : 32 GB - Windows Server 2008 R2 Enterprise : 1TB - Windows Server 2012 and Windows Server 2012 R2 : 4 TB Up to 1 TB of the main memory is available to each virtual machine. Up to 4 TB of the main memory is available to each virtual machine. NEC Corporation Revision 1.1 – May, 2016 14 SYSTEM CONFIGURATION GUIDE – NEC Express5800/T120g 4 Internal Hard Disk Drives 4.1 RAID Configuration Refer to the section in accordance with your disk form factor. 4.1.1 Hot Plug 2.5-inch Drive Configuration Refer to the section in accordance with your OS and RAID configuration. For example, when you would like to configure RAID 0/1/10 1GB cache with Windows Server 2012 R2, refer to the section 4.2.3 for the required components and then refer to the section 4.3.2 for the hard drives. Operating System Supported RAID configuration RAID and Cache Windows Server 2008 R2 KVM in Red Hat Enterprise Linux 6 (x86_64) VMware ESXi Windows Server 2012 Windows Server 2012 R2 Red Hat Enterprise Linux 6 (x86_64) without KVM feature Red Hat Enterprise Linux 7 Section Supported Drives Non-RAID (Embedded SATA) 4.2.1 4.3.1 RAID 0/1 (Embedded SATA RAID) (Windows only) 4.2.2 4.3.2 RAID 0/1/10 1GB Cache 4.2.3 4.3.3 RAID 5/6/50/60 1GB Cache 4.2.4 RAID 5/6/50/60 2GB Cache 4.2.5 Non-RAID (Embedded SATA) 4.2.1 4.3.1 RAID 0/1 (Embedded SATA RAID) (Windows only) 4.2.2 4.3.2 RAID 0/1/10 1GB Cache 4.2.3 4.3.4 RAID 5/6/50/60 1GB Cache 4.2.4 RAID 5/6/50/60 2GB Cache 4.2.5 NOTE: Up to four hard drives can be installed in the Embedded SATA configuration. Hot plug insertion/removal is not supported with the Embedded SATA non-RAID controller. Embedded SATA RAID controller is supported only on limited OS. For more details, please see OS Support Matrix for PCI Cards and Embedded Controllers. It is recommended to set RAID array configuration drives less than eight per disk group in order to minimize the risk of becoming multiple hard drives failure. To configure a large-capacity RAID array, it is recommended to configure in RAID 6 or RAID 60 in order to minimize the risk of becoming multiple hard drives failure during the RAID rebuilding process. NEC Corporation Revision 1.1 – May, 2016 15 SYSTEM CONFIGURATION GUIDE – NEC Express5800/T120g 4.1.2 Hot Plug 3.5-inch Drive Configuration Refer to the section in accordance with your OS and RAID configuration. Operating System Supported RAID configuration RAID and Cache Windows Server 2008 R2 VMware ESXi KVM in Red Hat Enterprise Linux 6 (x86_64) Windows Server 2012 Windows Server 2012 R2 Red Hat Enterprise Linux 6 (x86_64) without KVM feature Red Hat Enterprise Linux 7 Supported Drives Section Non-RAID (Embedded SATA) 4.2.6 4.3.5 RAID 0/1 (Embedded SATA RAID) (Windows only) 4.2.7 4.3.7 RAID 0/1/10 1GB Cache 4.2.8 4.3.8 RAID 5/6/50/60 1GB Cache 4.2.9 RAID 5/6/50/60 2GB Cache 4.2.10 Non-RAID (Embedded SATA) 4.2.6 4.3.6 RAID 0/1/10 1GB Cache 4.2.8 4.3.8 RAID 5/6/50/60 1GB Cache 4.2.9 RAID 5/6/50/60 2GB Cache 4.2.10 Non-RAID (Embedded SATA) 4.2.6 4.3.6 RAID 0/1 (Embedded SATA RAID) (Windows only) 4.2.7 4.3.7 RAID 0/1/10 1GB Cache 4.2.8 4.3.9 RAID 5/6/50/60 1GB Cache 4.2.9 RAID 5/6/50/60 2GB Cache 4.2.10 NOTE: Up to four hard drives can be installed in the Embedded SATA configuration. Hot plug insertion/removal is not supported with the Embedded SATA non-RAID controller. Embedded SATA RAID controller is supported only on limited OS. For more details, please see OS Support Matrix for PCI Cards and Embedded Controllers. All drives within a RAID array should be of the same capacity. It is recommended to set RAID array configuration drives less than eight per disk group in order to minimize the risk of becoming multiple hard drives failure. To configure a large-capacity RAID array, it is recommended to configure in RAID 6 or RAID 60 in order to minimize the risk of becoming multiple hard drives failure during the RAID rebuilding process. 4.2 Required Components for RAID Configuration 4.2.1 2.5-inch Drive Cage with Embedded SATA non-RAID Controller Category Product Name / Description Part Number Storage Controller Embedded SATA Controller 4 x 6Gb/s SATA 2.5-inch Hot Plug Drive Cage Kit 8 x 2.5-inch hot plug hard drive bays Including 2 sets of 1 x Mini SAS HD to 1 x Mini SAS HD cable (Standard) Drive Cage/ Cable N8154-77F Required NOTE: Up to 4 SATA drives are supported. For supported HDD/SSD, refer to 4.3.1 Hot plug insertion/removal are not supported in the configuration. NEC Corporation Revision 1.1 – May, 2016 16 SYSTEM CONFIGURATION GUIDE – NEC Express5800/T120g 4.2.2 2.5-inch Drive Cage with Embedded SATA RAID Controller Category Product Name / Description Part Number Storage Controller Embedded SATA Controller 4 x 6Gb/s SATA 2.5-inch Hot Plug Drive Cage Kit 8 x 2.5-inch hot plug hard drive bays Including 2 sets of 1 x Mini SAS HD to 1 x Mini SAS HD cable (Standard) Drive Cage/ Cable Required N8154-77F NOTE: Embedded SATA RAID controller is supported only on limited OS. For more details, please see OS Support Matrix for PCI Cards and Embedded Controllers. For supported HDD/SSD, refer to 4.3.2 4.2.3 2.5-inch Drive Cage with RAID 0/1 Controller with 1 GB Cache Category Product Name / Description Part Number Storage Controller Required RAID Controller (1GB, RAID 0/1) LSI MegaRAID SAS 9362-8i RAID 0/1/10, 1GB, Int. 8, PCIe 3.0 x8, 12Gb/s SAS Expander Card SAS Expander Card Including 2 sets of 1 x Mini SAS HD to 1 x Mini SAS HD cable NOTE: - Required when more than 1 drive cage N8103-176 Flash Backup Unit for LSI MegaRAID SAS 9362-8i 650mm Cable for Flash Backup Unit included 2.5-inch Hot Plug Drive Cage Kit 8 x 2.5-inch hot plug hard drive bays Including 2 sets of 1 x Mini SAS HD to 1 x Mini SAS HD cable N8103-181 SAS Expander Card Flash Backup Recommended Drive Cage/ Cable 1 to 3 Required N8103-186 N8154-77F NOTE: For supported HDD/SSD, refer to 4.3.3 for Windows Server 2008R2, Red Hat Enterprise Linux 6(x86_64) with KVM feature, or VMware. Refer to 4.3.4 for Windows Server 2012/2012R2, Red Hat Enterprise Linux 6(x86_64) without KVM feature, or Red Hat Enterprise Linux 7. All drives within a RAID array should be of the same type, capacity and rotation speed. Up to two kinds of drives selected from SAS 10K HDDs, SAS 15K HDDs, SATA HDDs, SAS SSDs, SATA SSDs (ME) and SATA SSDs (VE) can be mixed. 4.2.4 2.5-inch Drive Cage with RAID 5/6 Controller with 1 GB Cache Category Product Name / Description Part Number Storage Controller Required RAID Controller (1GB, RAID 0/1/5/6) LSI MegaRAID SAS 9362-8i RAID0/1/5/6/10/50/60, 1GB, Int. 8, PCIe 3.0 x8, SAS 12Gb/s, SATA 6Gb/s SAS Expander Card SAS Expander Card Including 2 sets of 1 x Mini SAS HD to 1 x Mini SAS HD cable NOTE: - Required when more than 1 drive cage N8103-177 Flash Backup Unit for LSI MegaRAID SAS 9362-8i 650mm Cable for Flash Backup Unit included 2.5-inch Hot Plug Drive Cage Kit 8 x 2.5-inch hot plug hard drive bays Including 2 sets of 1 x Mini SAS HD to 1 x Mini SAS HD cable N8103-181 SAS Expander Card Flash Backup Recommended Drive Cage/ Cable 1 to 3 Required NEC Corporation Revision 1.1 – May, 2016 N8103-186 N8154-77F 17 SYSTEM CONFIGURATION GUIDE – NEC Express5800/T120g NOTE: For supported HDD/SSD, refer to 4.3.3 for Windows Server 2008R2, Red Hat Enterprise Linux 6(x86_64) with KVM feature, or VMware. Refer to 4.3.4 for Windows Server 2012/2012R2, Red Hat Enterprise Linux 6(x86_64) without KVM feature, or Red Hat Enterprise Linux 7. All drives within a RAID array should be of the same type, capacity and rotation speed. Up to two kinds of drives selected from SAS 10K HDDs, SAS 15K HDDs, SATA HDDs, SAS SSDs, SATA SSDs (ME) and SATA SSDs (VE) can be mixed. To configure a large-capacity RAID array, it is recommended to configure in RAID 6 or RAID 60 in order to minimize the risk of becoming multiple hard drives failure during the RAID rebuilding process. 4.2.5 2.5-inch Drive Cage with RAID 5/6 Controller with 2 GB Cache Category Product Name / Description Part Number Storage Controller Required RAID Controller (2GB, RAID 0/1/5/6) LSI MegaRAID SAS 9362-8i RAID0/1/5/6/10/50/60, 2GB, Int. 8, PCIe 3.0 x8, 12Gb/s SAS Expander Card SAS Expander Card Including 2 sets of 1 x Mini SAS HD to 1 x Mini SAS HD cable NOTE: - Required when more than 1 drive cage N8103-178 Flash Backup Unit for LSI MegaRAID SAS 9362-8i 650mm Cable for Flash Backup Unit included 2.5-inch Hot Plug Drive Cage Kit 8 x 2.5-inch hot plug hard drive bays Including 2 sets of 1 x Mini SAS HD to 1 x Mini SAS HD cable N8103-181 SAS Expander Card Flash Backup Recommended Drive Cage/ Cable 1 to 3 Required N8103-186 N8154-77F NOTE: For supported HDD/SSD, refer to 4.3.3 for Windows Server 2008R2, Red Hat Enterprise Linux 6(x86_64) with KVM feature, or VMware. Refer to 4.3.4 for Windows Server 2012/2012R2, Red Hat Enterprise Linux 6(x86_64) without KVM feature, or Red Hat Enterprise Linux 7. All drives within a RAID array should be of the same type, capacity and rotation speed. Up to two kinds of drives selected from SAS 10K HDDs, SAS 15K HDDs, SATA HDDs, SAS SSDs, SATA SSDs (ME) and SATA SSDs (VE) can be mixed. To configure a large-capacity RAID array, it is recommended to configure in RAID 6 or RAID 60 in order to minimize the risk of becoming multiple hard drives failure during the RAID rebuilding process 4.2.6 3.5-inch Drive Cage with Embedded SATA non-RAID Controller Category Product Name / Description Part Number Storage Controller Embedded SATA Controller 4 x 6Gb/s SATA 3.5-inch Hot Plug Drive Cage Kit 4 x 3.5-inch hot plug hard drive bays Including 1 sets of 1 x Mini SAS HD to 1 x Mini SAS HD cable (Standard) Drive Cage/ Cable Required N8154-78F NOTE: Up to 4 SATA drives are supported For supported HDD/SSD, refer to 4.3.5 for Windows Server 2008R2, or Red Hat Enterprise Linux 6(x86_64) with KVM feature. Refet to 4.3.6 for Windows Server 2012/2012R2, Red Hat Enterprise Linux 6(x86_64) without KVM feature. Refer to 4.3.5 for VMware. Hot plug insertion/removal is not supported with the Embedded SATA non-RAID controller. NEC Corporation Revision 1.1 – May, 2016 18 SYSTEM CONFIGURATION GUIDE – NEC Express5800/T120g 4.2.7 3.5-inch Drive Cage with Embedded SATA RAID Controller Category Product Name / Description Part Number Storage Controller Embedded SATA Controller 4 x 6Gb/s SATA 3.5-inch Hot Plug Drive Cage Kit 4 x 3.5-inch hot plug hard drive bays Including 1 sets of 1 x Mini SAS HD to 1 x Mini SAS HD cable (Standard) Drive Cage/ Cable N8154-78F Required NOTE: Up to 4 SATA drives are supported For supported HDD/SSD, refer to 4.3.7 4.2.8 3.5-inch Drive Cage with RAID 0/1 Controller with 1 GB Cache Category Product Name / Description Part Number Storage Controller Required RAID Controller (1GB, RAID 0/1) LSI MegaRAID SAS 9362-8i RAID 0/1/10, 1GB, Int. 8, PCIe 3.0 x8, 12Gb/s Flash Backup Unit for LSI MegaRAID SAS 9362-8i 650mm Cable for Flash Backup Unit included 3.5-inch Drive Cage 4 x 3.5-inch hot plug hard drive bays Including 1 sets of 1 x Mini SAS HD to 1 x Mini SAS HD cable N8103-176 Flash Backup Recommended Drive Cage/ Cable 1 to 2 Required N8103-181 N8154-78F NOTE: For supported HDD/SSD, refer to 4.3.8 for Windows Server 2008R2 or Red Hat Enterprise Linux 6(x86_64) with KVM feature. Refer to 4.3.9 for Windows Server 2012/2012R2, Red Hat Enterprise Linux 6(x86_64) without KVM feature. Refer to 4.3.8 for VMware. All drives within a RAID array should be of the same capacity. 4.2.9 3.5-inch Drive Cage with RAID 5/6 Controller with 1 GB Cache Category Product Name / Description Part Number Storage Controller Required RAID Controller (1GB, RAID 0/1/5/6) LSI MegaRAID SAS 9362-8i RAID0/1/5/6/10/50/60, 1GB, Int. 8, PCIe 3.0 x8, SAS 12Gb/s, SATA 6Gb/s Flash Backup Unit for LSI MegaRAID SAS 9362-8i 650mm Cable for Flash Backup Unit included 3.5-inch Drive Cage 4 x 3.5-inch hot plug hard drive bays Including 1 sets of 1 x Mini SAS HD to 1 x Mini SAS HD cable N8103-177 Flash Backup Recommended Drive Cage/ Cable 1 to 2 Required N8103-181 N8154-78F NOTE: For supported HDD/SSD, refer to 4.3.8 for Windows Server 2008R2 or Red Hat Enterprise Linux 6(x86_64) with KVM feature. Refer to 4.3.9 for Windows Server 2012/2012R2, Red Hat Enterprise Linux 6(x86_64) without KVM feature. Refer to 4.3.8 for VMware. All drives within a RAID array should be of the same capacity. To configure a large-capacity RAID array, it is recommended to configure in RAID 6 or RAID 60 in order to minimize the risk of becoming multiple hard drives failure during the RAID rebuilding process. NEC Corporation Revision 1.1 – May, 2016 19 SYSTEM CONFIGURATION GUIDE – NEC Express5800/T120g 4.2.10 3.5-inch Drive Cages with RAID 5/6 Controller with 2 GB Cache Category Product Name / Description Part Number Storage Controller Required RAID Controller (2GB, RAID 0/1/5/6) LSI MegaRAID SAS 9362-8i RAID0/1/5/6/10/50/60, 2GB, Int. 8, PCIe 3.0 x8, 12Gb/s Flash Backup Unit for LSI MegaRAID SAS 9362-8i 650mm Cable for Flash Backup Unit included 3.5-inch Drive Cage 4 x 3.5-inch hot plug hard drive bays Including 1 sets of 1 x Mini SAS HD to 1 x Mini SAS HD cable N8103-178 Flash Backup Recommended Drive Cage/ Cable 1 to 2 Required N8103-181 N8154-78F NOTE: For supported HDD/SSD, refer to 4.3.8 for Windows Server 2008R2 or Red Hat Enterprise Linux 6(x86_64) with KVM feature. Refer to 4.3.9 for Windows Server 2012/2012R2, Red Hat Enterprise Linux 6(x86_64) without KVM feature. Refer to 4.3.8 for VMware. All drives within a RAID array should be of the same capacity. To configure a large-capacity RAID array, it is recommended to configure in RAID 6 or RAID 60 in order to minimize the risk of becoming multiple hard drives failure during the RAID rebuilding process. 4.3 Supported Drives 4.3.1 2.5-inch Drives for Embedded SATA Controller Category Drive 4 slots available 2.5-inch SATA HDD Product Name / Description Part Number 500GB 7.2K Hot Plug 2.5-inch SATA HDD 1 x 500 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm, 512n sector 1TB 7.2K Hot Plug 2.5-inch SATA HDD 1 x 1 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm, 512n sector 2TB 7.2K Hot Plug 2.5-inch SATA HDD 1 x 2 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm, 512n sector N8150-488 N8150-489 N8150-527 NOTE: Hot plug insertion/removal is not supported with the configuration. 4.3.2 2.5-inch Drives for Embedded SATA RAID Controller Category Drive 4 slots available 2.5-inch SATA HDD Product Name / Description Part Number 500GB 7.2K Hot Plug 2.5-inch SATA HDD 1 x 500 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm, 512n sector 1TB 7.2K Hot Plug 2.5-inch SATA HDD 1 x 1 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm, 512n sector 2TB 7.2K Hot Plug 2.5-inch SATA HDD 1 x 2 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm, 512n sector N8150-488 N8150-489 N8150-527 NOTE: All hard drives within a RAID array should be of the same capacity. NEC Corporation Revision 1.1 – May, 2016 20 SYSTEM CONFIGURATION GUIDE – NEC Express5800/T120g 4.3.3 2.5-inch Drives for RAID Controller Configuration (1) For Windows Server 2008R2, KVM in Red Hat Enterprise Linux 6(x86_64), or VMware Category Drive Standard:8 slots available Max : 24 slots available SAS HDD (512n) SATA HDD (512n) SAS SSD (ME) SATA SSD (ME) SATA SSD (VE) Product Name / Description Part Number 300GB 10K Hot Plug 2.5-inch SAS HDD 1 x 300 GB SAS HDD, 2.5-inch, 12Gb/s, 10,000 rpm, 512n sector 450GB 10K Hot Plug 2.5-inch SAS HDD 1 x 450 GB SAS HDD, 2.5-inch, 12Gb/s, 10,000 rpm, 512n sector 600GB 10K Hot Plug 2.5-inch SAS HDD 1 x 600 GB SAS HDD, 2.5-inch, 12Gb/s, 10,000 rpm, 512n sector 900GB 10K Hot Plug 2.5-inch SAS HDD 1x 900 GB SAS HDD, 2.5-inch, 12Gb/s, 10,000 rpm, 512n sector 1.2TB 10K Hot Plug 2.5-inch SAS HDD 1 x 1.2TB SAS HDD, 2.5-inch, 12Gb/s, 10,000 rpm, 512n sector 300GB 15K Hot Plug 2.5-inch SAS HDD 1x 300 GB SAS HDD, 2.5-inch, 12Gb/s, 15,000 rpm, 512n sector 450GB 15K Hot Plug 2.5-inch SAS HDD 1x 450 GB SAS HDD, 2.5-inch, 12Gb/s, 15,000 rpm, 512n sector 600GB 15K Hot Plug 2.5-inch SAS HDD 1x 600 GB SAS HDD, 2.5-inch, 12Gb/s, 15,000 rpm, 512n sector 500GB 7.2K Hot Plug 2.5-inch SATA HDD 1 x 500 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm, 512n sector 1TB 7.2K Hot Plug 2.5-inch SATA HDD 1 x 1 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm, 512n sector 2TB 7.2K Hot Plug 2.5-inch SATA HDD 1 x 2 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm, 512n sector 200GB Hot Plug 2.5-inch SAS SSD 1 x 200 GB SAS SSD, eMLC, 2.5-inch, 12Gb/s, 512n sector 400GB Hot Plug 2.5-inch SAS SSD 1 x 400 GB SAS SSD, eMLC, 2.5-inch, 12Gb/s, 512n sector N8150-479 200GB Hot Plug 2.5-inch SATA SSD 1 x 200 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, ME 400GB Hot Plug 2.5-inch SATA SSD 1 x 400 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, ME 800GB Hot Plug 2.5-inch SATA SSD 1 x 800 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, ME 200GB Hot Plug 2.5-inch SATA SSD 1 x 200 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, VE 400GB Hot Plug 2.5-inch SATA SSD 1 x 400 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, VE 800GB Hot Plug 2.5-inch SATA SSD 1 x 800 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, VE 1.6TB Hot Plug 2.5-inch SATA SSD 1 x 1.6 TB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, VE N8150-725 N8150-480 N8150-481 N8150-482 N8150-483 N8150-485 N8150-486 N8150-518 N8150-488 N8150-489 N8150-527 N8150-721 N8150-722 N8150-726 N8150-727 N8150-732 N8150-733 N8150-734 N8150-735 NOTE: All drives within a RAID array should be of the same type, capacity and rotation speed. Up to two kinds of drives selected from SAS 10K HDDs, SAS 15K HDDs, SATA HDDs, SAS SSDs, NEC Corporation Revision 1.1 – May, 2016 21 SYSTEM CONFIGURATION GUIDE – NEC Express5800/T120g SATA SSDs (ME) and SATA SSDs (VE) can be mixed in each drive cage. To configure a large-capacity RAID array, it is recommended to configure in RAID 6 or RAID 60 in order to minimize the risk of becoming multiple hard drives failure during the RAID rebuilding process. The 2.5-inch SAS/SATA SSDs have limited lifetime. Refer to Endurance of SSD for details. 4.3.4 2.5-inch Drives for RAID Controller Configuration (2) For Windows Server 2012/2012R2, Red Hat Enterprise Linux 6(x86_64) without KVM, or Red Hat Enterprise Linux 7 Category Drive Standard : 8 slots available Max : 24 slots available SAS HDD (512n) SAS HDD (4Kn) SATA HDD (512n) SAS SSD (ME) SATA SSD (ME) NEC Corporation Product Name / Description Part Number 300GB 10K Hot Plug 2.5-inch SAS HDD 1 x 300 GB SAS HDD, 2.5-inch, 12Gb/s, 10,000 rpm, 512n sector 450GB 10K Hot Plug 2.5-inch SAS HDD 1 x 450 GB SAS HDD, 2.5-inch, 12Gb/s, 10,000 rpm, 512n sector 600GB 10K Hot Plug 2.5-inch SAS HDD 1 x 600 GB SAS HDD, 2.5-inch, 12Gb/s, 10,000 rpm, 512n sector N8150-479 900GB 10K Hot Plug 2.5-inch SAS HDD 1x 900 GB SAS HDD, 2.5-inch, 12Gb/s, 10,000 rpm, 512n sector 1.2TB 10K Hot Plug 2.5-inch SAS HDD 1 x 1.2TB SAS HDD, 2.5-inch, 12Gb/s, 10,000 rpm, 512n sector 300GB 15K Hot Plug 2.5-inch SAS HDD 1x 300 GB SAS HDD, 2.5-inch, 12Gb/s, 15,000 rpm, 512n sector 450GB 15K Hot Plug 2.5-inch SAS HDD 1x 450 GB SAS HDD, 2.5-inch, 12Gb/s, 15,000 rpm, 512n sector 600GB 15K Hot Plug 2.5-inch SAS HDD 1x 600 GB SAS HDD, 2.5-inch, 12Gb/s, 15,000 rpm, 512n sector 1.8TB 10K Hot Plug 2.5-inch SAS HDD 1x 1.8TB SAS HDD, 2.5-inch, 12Gb/s, 10,000 rpm, 4Kn sector N8150-482 500GB 7.2K Hot Plug 2.5-inch SATA HDD 1 x 500 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm, 512n sector 1TB 7.2K Hot Plug 2.5-inch SATA HDD 1 x 1 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm, 512n sector 2TB 7.2K Hot Plug 2.5-inch SATA HDD 1 x 2 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm, 512n sector 200GB Hot Plug 2.5-inch SAS SSD 1 x 200 GB SAS SSD, eMLC, 2.5-inch, 12Gb/s, 512n sector 400GB Hot Plug 2.5-inch SAS SSD 1 x 400 GB SAS SSD, eMLC, 2.5-inch, 12Gb/s, 512n sector N8150-488 200GB Hot Plug 2.5-inch SATA SSD 1 x 200 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, ME 400GB Hot Plug 2.5-inch SATA SSD 1 x 400 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, ME 800GB Hot Plug 2.5-inch SATA SSD 1 x 800 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, ME N8150-725 Revision 1.1 – May, 2016 N8150-480 N8150-481 N8150-483 N8150-485 N8150-486 N8150-518 N8150-490 N8150-489 N8150-527 N8150-721 N8150-722 N8150-726 N8150-727 22 SYSTEM CONFIGURATION GUIDE – NEC Express5800/T120g SATA SSD (VE) 200GB Hot Plug 2.5-inch SATA SSD 1 x 200 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, VE 400GB Hot Plug 2.5-inch SATA SSD 1 x 400 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, VE 800GB Hot Plug 2.5-inch SATA SSD 1 x 800 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, VE 1.6TB Hot Plug 2.5-inch SATA SSD 1 x 1.6 TB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, VE N8150-732 N8150-733 N8150-734 N8150-735 NOTE: All drives within a RAID array should be of the same type, capacity and rotation speed. Up to two kinds of drives selected from SAS 10K HDDs, SAS 15K HDDs, SATA HDDs, SAS SSDs, SATA SSDs (ME) and SATA SSDs (VE) can be mixed in each drive cage. To configure a large-capacity RAID array, it is recommended to configure in RAID 6 or RAID 60 in order to minimize the risk of becoming multiple hard drives failure during the RAID rebuilding process. The 4Kn sector drives are make-to-order products. Please consult your sales representative in regard to production lead time. When you select 4KB sector HDD, confirm whether your applications support hard drives with 4 KB sector size. For more information, visit the NEC website at: http://www.nec.com/en/global/prod/express/svropt/hdd/collateral/4KHDD_Precautions_EN.pdf 512n sector HDD and 4Kn sector HDD cannot be mixed. The 2.5-inch SAS/SATA SSDs have limited lifetime. Refer to Endurance of SSD for details. 4.3.5 3.5-inch Drives for Embedded SATA Controller For Windows Server 2008R2 or VMware Category Drive 4slots available 3.5-Inch SATA HDD Product Name / Description Part Number 500GB 7.2K Hot Plug 3.5-inch SATA HDD 1 x 500 GB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512n Sector 1TB 7.2K Hot Plug 3.5-inch SATA HDD 1 x 1 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512n Sector 2TB 7.2K Hot Plug 3.5-inch SATA HDD 1 x 2 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512n Sector N8150-524 N8150-504 N8150-505 NOTE: Hot plug insertion/removal are not supported in the configuration. 4.3.6 3.5-inch Drives for Embedded SATA Controller For Windows Server 2012/2012R2, Red Hat Enterprise Linux 6 (x86_64), or Red Hat Enterprise Linux 7 Category Drive 4slots available 3.5-inch SATA HDD Product Name / Description Part Number 500GB 7.2K Hot Plug 3.5-inch SATA HDD 1 x 500 GB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512n Sector 1TB 7.2K Hot Plug 3.5-inch SATA HDD 1 x 1 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512n Sector 2TB 7.2K Hot Plug 3.5-inch SATA HDD 1 x 2 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512n Sector 3TB 7.2K Hot Plug 3.5-inch SATA HDD 1 x 3 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512n Sector 4TB 7.2K Hot Plug 3.5-inch SATA HDD 1 x 4 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512n Sector N8150-524 N8150-504 N8150-505 N8150-506 N8150-507 NOTE: Hot plug insertion/removal are not supported in the configuration. NEC Corporation Revision 1.1 – May, 2016 23 SYSTEM CONFIGURATION GUIDE – NEC Express5800/T120g 4.3.7 3.5-inch Drives for Embedded SATA RAID Controller Category Drive 4 slots available 3.5-inch SATA HDD Product Name / Description Part Number 500GB 7.2K Hot Plug 3.5-inch SATA HDD 1 x 500 GB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512n Sector 1TB 7.2K Hot Plug 3.5-inch SATA HDD 1 x 1 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512n Sector 2TB 7.2K Hot Plug 3.5-inch SATA HDD 1 x 2 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512n Sector 3TB 7.2K Hot Plug 3.5-inch SATA HDD 1 x 3 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512n Sector 4TB 7.2K Hot Plug 3.5-inch SATA HDD 1 x 4 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512n Sector N8150-524 N8150-504 N8150-505 N8150-506 N8150-507 NOTE: All drives within a RAID array should be of the same capacity. Embedded SATA RAID Controller does not support RAID 10 configured with 2 TB, 3 TB, and 4 TB HDDs. 4.3.8 3.5-inch Drives for RAID Controller Configuration (1) For Windows Server 2008/2008R2, Red Hat Enterprise Linux 6, KVM in Red Hat Enterprise Linux 6(x86_64), or VMware Category Drive Standard:4 slots available Max : 8 slots available 3.5-inch SATA HDD Product Name / Description Part Number 500GB 7.2K Hot Plug 3.5-inch SATA HDD 1 x 500 GB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512n Sector 1TB 7.2K Hot Plug 3.5-inch SATA HDD 1 x 1 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512n Sector 2TB 7.2K Hot Plug 3.5-inch SATA HDD 1 x 2 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512n Sector 3TB 7.2K Hot Plug 3.5-inch SATA HDD 1 x 3 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512n Sector 4TB 7.2K Hot Plug 3.5-inch SATA HDD 1 x 4 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512n Sector N8150-524 N8150-504 N8150-505 N8150-506 N8150-507 NOTE: All drives within a RAID array should be of the same capacity. To configure a large-capacity RAID array, it is recommended to configure in RAID 6 or RAID 60 in order to minimize the risk of becoming multiple hard drives failure during the RAID rebuilding process. 4.3.9 3.5-inch Drives for RAID Controller Configuration (2) Category Drive Standard : 4 slots available Max : 8 slots available 3.5-inch SATA HDD (512n) 3.5-inch SATA HDD (4Kn) Product Name / Description Part Number 500GB 7.2K Hot Plug 3.5-inch SATA HDD 1 x 500 GB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512 Sector 1TB 7.2K Hot Plug 3.5-inch SATA HDD 1 x 1 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512 Sector 2TB 7.2K Hot Plug 3.5-inch SATA HDD 1 x 2 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512 Sector 3TB 7.2K Hot Plug 3.5-inch SATA HDD 1 x 3 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512 Sector 4TB 7.2K Hot Plug 3.5-inch SATA HDD 1 x 4 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512 Sector 6TB 7.2K Hot Plug 3.5-inch SATA HDD 1 x 6 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 4K Sector N8150-524 N8150-504 N8150-505 N8150-506 N8150-507 N8150-503 NOTE: NEC Corporation Revision 1.1 – May, 2016 24 SYSTEM CONFIGURATION GUIDE – NEC Express5800/T120g All hard drives within a RAID array should be of the same capacity. When you select 4Kn sector HDD, confirm whether your applications support hard drives with 4 Kn sector size. For more information, visit the NEC website at: http://www.nec.com/en/global/prod/express/svropt/hdd/collateral/4KHDD_Precautions_EN_Rev01.pdf Mix configurations of 4Kn sector HDDs and 512n sector HDDs are not supported. 5 Optical Drive Available bay: 1 Product Name / Description Part Number Internal Slim DVD-ROM drive Slim DVD-ROM drive DVD read speed: 8x (DVD-ROM / DVD-R / DVD-RW) CD read speed: 24x (CD-ROM / CD-R/RW) Internal DVD Super Multi Drive Slim DVD Super Multi drive, not including writing software DVD Read speed: 8x (DVD-R / DVD-RW / DVD-R DL / DVD+R / DVD+RW / DVD+R DL / DVD-ROM) DVD-RAM read speed: 5x CD read speed: 24x (CD-ROM / CD-R/RW) N8151-134 N8151-135F 6 Internal Tape / RDX Drives 6.1 Tape / RDX Drive Selection Refer to the section in accordance with your type of tape drives: RDX: Refer to 6.2.1 LTO: Refer to 6.2.2 NOTE: Tape devices cannot be directly connected to VMware ESXi servers. For an ESXi environment, it is recommended to connect and configure an additional backup server via network. 6.2 Tape / RDX Configuration 6.2.1 RDX Drive Category Product Name / Description Part Number Controller Internal USB Controller 1 x USB port Internal USB cable 1 x Internal USB to 1 x USB device, USB 3.0 (Standard) Internal RDX (USB) N8151-125 Category Product Name / Description Part Number Controller Required SAS Controller LSI SAS9212-4i4e Host Bus Adapter 6Gbps SAS, Int. 4, Ext. 4, 7-pin SATA / SFF-8088, PCIe 2.0 x8 NOTE: - For using this product in Windows Server 2012 R2 environment, download the driver from the NEC website. N8103-142 Cable Drive 1 drive available 6.2.2 NEC Corporation K410-275(00) LTO Drive Revision 1.1 – May, 2016 25 SYSTEM CONFIGURATION GUIDE – NEC Express5800/T120g Cable Required Internal SAS Cable Drive 1 drive available Internal LTO (SAS) LTO3, Half height, Native capacity 400 GB Internal LTO (SAS) LTO4, Half height, Native capacity 800 GB Internal LTO (SAS) K410-217(00) 1x 7-pin Single SATA to 1x SFF-8482 SAS N8151-126 N8151-127 N8151-128 LTO5, Half height, Native capacity 1.5 TB Internal LTO (SAS) N8151-129 LTO6, Half height, Native capacity 2.5 TB 7 PCI Card Please refer to Supported PCI Cards and Installable Slots with regard to the position of PCI slot which can mount PCI card supported. 7.1 Graphics Card Installation Kit For GPU card installation Product Name / Description Part Number Graphics Card Installation Kit Power cables for video card, a retainer to secure the graphics board NOTE: - This option is applicable to N8100-2479F (1000W power supply model) only. N8116-48 NOTE: Since this product is make-to-order manufacturing, the support is provided individually. Contact your sales representative for details. There are following limitations on configuration to use this option - Up to two HDDs can be installed in N8154-77F 2.5-inch Hot Plug Drive Cage Kit. - Up to one HDD can be installed in N8154-78F 3.5-inch Hot Plug Drive Cage Kit. - N8181-130F Redundant Fan Kit cannot be installed. - The operable ambient temperature is up to 35° C. This product does not support/guarantee installation of general video cards on T120g. Please consult with your sales representative for the tested GPU cards. 7.2 Network Interface Controller Category Adapter NEC Corporation GbE Product Name / Description Part Number 1000BASE-T Adapter Broadcom ® BCM5718 Gigabit Ethernet Controller PCIe 2.0 x1 Dual Port 1000BASE-T Adapter Broadcom ® BCM5718 Gigabit Ethernet Controller PCIe 2.0 x1 Dual Port 1000BASE-T Adapter Intel® 82580 Gigabit Ethernet Controller PCIe 2.0 x4 NOTE: - PXE boot is not supported on UEFI environment. N8104-150 Revision 1.1 – May, 2016 N8104-151 N8104-145 26 SYSTEM CONFIGURATION GUIDE – NEC Express5800/T120g 10GbE SFP+ Module Quad Port 1000BASE-T Adapter Broadcom ® BCM5719 Gigabit Ethernet Controller PCIe 2.0 x4 NOTE: - Network cables with RJ-45 plug covers cannot be used. N8104-152 10GBASE SFP+ Adapter (SFP+/2ch) Qlogic NetXtreme II BCM57810S PCIe 2.0 x8, Low Profile / Full Height NOTE: - N8104-129 SFP+ Module is required to connect with an optical cable. - The latest driver is required for Window Server 2008 and Windows Server 2008 R2. Dual Port 10GBASE-T Adapter Intel® Ethernet Controller X540 PCIe 2.0(x8) , Low Profile / Full Height Dual Port 10GBASE-T Adapter Intel® Ethernet Controller X550 PCIe 3.0 x4 SFP+ Module (10G-SR) 1 x SFP+ Module for N8104-149 N8104-149 N8104-153 N8104-157 N8104-129 NOTE: Supports up to three 10GbE network adapters in a single-processor configuration. Network performance may be reduced depending on the applications and memory performance when three or more 10GbE Network Adapters are installed. For VMware ESXi 5.5 and ESXi 6.0, there are some limitations concerning the number of installable PCI cards. Refer to Supported PCI Cards and Installable Slots for details. NIC Teaming feature – NIC Teaming and bonding features See the table below for supported network interfaces and OS combinations. Windows Server 2008 R2 supports BASP (Broadcom Advanced Server Program) teaming while Windows Server 2012 or later and Linux support teaming with bonding function supported by OS. Network Interface Team Operating Systems 1GbE NIC Embedded 1GbE NIC and N8104-150/-151/-152 Up to four ports per one team Windows Server 2008 R2 Windows Server 2012 Windows Server 2012 R2 Red Hat Enterprise Linux 1GbE NIC N8104-145 10GbE NIC N8104-149 Up to four ports per one team Windows Server 2008 R2 Up to four ports per one team Windows Server 2008 R2 Windows Server 2012 Windows Server 2012 R2 Red Hat Enterprise Linux 10GbE NIC N8104-153/-157 Up to four ports per one team Windows Server 2012 Windows Server 2012 R2 Red Hat Enterprise Linux NOTE: NIC Teaming feature is not supported on iSCSI interfaces. The network interfaces for each teaming must be the same. When 10GbE and 1GbE NIC teaming are mixed, the maximum number of team must be as follows: - Windows Server 2008 R2 : up to four per one system - Windows Server 2012, Windows Server 2012 R2 : up to five per one system - Red Hat Enterprise Linux : up to five per one system NEC Corporation Revision 1.1 – May, 2016 27 SYSTEM CONFIGURATION GUIDE – NEC Express5800/T120g Using iSCSI See the table below for supported network interfaces and OS combinations. Category Network Interface Operating Systems 1GbE Embedded 1GbE NIC/ N8104-150/-151/-152 Windows Server 2008 R2, Windows Server 2012, Windows Server 2012 R2, Red Hat Enterprise Linux, VMware N8104-145 Windows Server 2008 R2, VMware N8104-149 Windows Server 2008 R2, Windows Server 2012, Windows Server 2012 R2, Red Hat Enterprise Linux, VMware N8104-153 Windows Server 2012, Windows Server 2012 R2 Red Hat Enterprise Linux, VMware N8104-157 Windows Server 2012, Windows Server 2012 R2 Red Hat Enterprise Linux 10GbE NOTE: Teaming feature is not supported on iSCSI interfaces. 7.3 External Storage Controller 7.3.1 External RAID Controller Category Product Name / Description Part Number Controller RAID Controller (2GB, RAID0/1/5/6) LSI MegaRAID SAS 9380-8e RAID0/1/5/6/10/50/60, 2GB, Ext. 8, PCIe 3.0 x8, SAS 12Gb/s, SATA 6Gb/s Flash Backup Unit included N8103-179 NOTE: To configure a large-capacity RAID array, it is recommended to configure in RAID 6 or RAID 60 in order to minimize the risk of becoming multiple hard drives failure during the RAID rebuilding process. It is recommended to set RAID array configuration drives less than eight in order to minimize the risk of becoming multiple hard drives failure. 7.3.2 Fibre Channel / SAS Controller Category Product Name / Description Part Number Fibre Channel Fibre Channel Controller (1ch) Emulex LightPulse LPe1250-F8 Host Bus Adapter 8Gb/s, Optical, PCIe 2.0 x8 Fibre Channel Controller (2ch) Emulex LightPulse LPe12002-M8 Host Bus Adapter 8Gb/s, Optical, PCIe 2.0 x8 Fibre Channel Controller (1ch) Emulex LightPulse LPe16000B-M6 Host Bus Adapter 16Gb/s, Optical, PCIe 3.0 x8 Fibre Channel Controller (2ch) Emulex LightPulse LPe16002B-M6 Host Bus Adapter 16Gb/s, Optical, PCIe 3.0 x8 SAS Controller LSI SAS9212-4i4e Host Bus Adapter 6Gb/s SAS, Int. 4 / Ext. 4, 7-pin SATA / SFF-8088, PCIe 2.0 x8 N8190-159 SAS NEC Corporation Revision 1.1 – May, 2016 N8190-160 N8190-157A N8190-158A N8103-142 28 SYSTEM CONFIGURATION GUIDE – NEC Express5800/T120g SAS Controller LSI SAS9300-8e Host Bus Adapter 12Gb/s SAS, ext. 8(SFF-8644 x2), PCIe 3.0 x8 N8103-184 NOTE: With regard to 16Gb/s Fiber Channel Controllers, up to two ports in a single processor configuration with Xeon E5-2603 v4, and up to six ports in a dual processor configuration with Xeon E5-2603 v4 are allowed in the system. For VMware ESXi 5.5 and ESXi 6.0, there are some limitations concerning the number of installable PCI cards. Refer to Supported PCI Cards and Installable Slots for details. Up to three SAS Controllers can be installed. 7.4 Serial Port Adapter Product Name / Description Part Number Serial Port Adapter N8117-01A Serial port fixed to PCI bracket NOTE: Up to one Serial Port Adapter can be installed. 8 Other Add-in Components 8.1 Redundant Fan Product Name / Description Part Number Redundant Fan Kit Hot plug Cooling Fan for T120g NOTE: - The Cooling fan for 700W non-hot plug PSU does not support hot-plug feature. Non-redundant Fan Kit Non-hot plug Cooling Fan for T120g N8181-130F N8181-131F NOTE: One of the fan kits must be installed. 8.2 Trusted Platform Module Kit Product Name / Description Part Number Trusted Platform Module Kit TPM 2.0 module N8115-26 NOTE: The kit is not available in China. The kit is not removable after attachment. "TPM Support" in BIOS setup menu must be activated prior to use of this kit. To use Windows BitLocker drive encryption, be sure to keep the "recovery password" of BitLocker function. The recovery password is required to restore data for hardware replacement during a system error. NEC Corporation Revision 1.1 – May, 2016 29 SYSTEM CONFIGURATION GUIDE – NEC Express5800/T120g 8.3 Internal Flash Memory Product Name / Description Part Number VMware ESXi support kit Internal USB flash memory to install VMware ESXi system N8106-009 NOTE: The kit does not include VMware ESXi installation media and license. 8.4 High Temperature Support Option Product Name / Description Part Number High temperature resistant Kit Required for high temperature operation over 40°C (up to 45°C) N8181-147F NOTE: This option is applicable to only N8100-2478F (800W power supply model). To apply this option, there are some configuration limitations below. There are following limitations on configuration to use this option: - Up to two 2.5-inch drive cages of N8154-77F can be installed. - Up to one 3.5-inch drive cage of N8154-78F can be installed. - The following options cannot be installed: N8101-1075F Xeon E5-2690 v4 Processor Kit N8101-1076F Xeon E5-2697 v4 Processor Kit N8102-689F 32GB DDR4-2400 REG Memory Kit(1x32GB) N8151-125 Internal RDX (USB) N8151-126 Internal LTO (SAS) N8151-127 Internal LTO (SAS) N8151-128 Internal LTO (SAS) N8151-129 Internal LTO (SAS) N8181-130F Redundant Fan Kit N8146-91 Dust Proof Bezel with Sensor N8146-92 Dust Proof Bezel N8116-48 Graphics Card Installation Kit 8.5 Flash FDD Choose the Flash FDD if you need to prepare an alternative for a floppy drive. Product Name / Description Part Number Flash FDD USB flash emulating USB floppy disk, Native capacity 1.44 MB N8160-96 NOTE: Up to one drive can be connected. NEC Corporation Revision 1.1 – May, 2016 30 SYSTEM CONFIGURATION GUIDE – NEC Express5800/T120g 9 Add-on Components 9.1 Input Devices Product Name / Description Part Number Keyboard 1 x 104-keys USB keyboard USB Optical Mouse 1 x USB Mouse, 2-button, Optical with wheel N8170-25 N8170-22 NOTE: Keyboard and mouse are not included in the base models. Please order separately if necessary. 9.2 Server Management License for the standard management features. For more extensive remote KVM and remote media features, choose the following kit. Product Name / Description Part Number Remote KVM and Media License Kit N8115-04 License for one server. Remote KVM and remote media are enabled regardless of OS status. Remote KVM: Displays a graphics console on the web browser of the remote terminal (PC/server). Controls keyboard and mouse via the remote terminals' web browser Remote media: Enables the user to use the CD / DVD / FD / Flash memory of the remote terminals (PC/server) as if accessing the local drives. NOTE: Remote KVM and remote media features are not available for virtual machines. 9.3 Rack Conversion Kit The following rack conversion kit is required to install the server into a 19-inch rack system: Product Name / Description Part Number Rack Conversion Kit Convert to 5U form factor N8143-119 9.4 Dust / Insect Proof Kit The server supports the dust resistant feature. Choose the following kit to install the system in dusty places. Category Product Name / Description Part Number Front Bezel Dust Proof Bezel with Sensor Including 1 set of filter replacement sensors, 1 set of dust proof filters Dust Proof Bezel Including 1 set of dust proof filters Dust proof filter (5 pcs.) For N8146-91 and N8146-92 Dust Proof Bezel Removal capacity of particles : Up to 1 μm-sized Filter Replacement Sensor For N8146-92 Dust Proof Bezel, Including 1 set of filter replacement sensors N8146-91 Filter Sensor NEC Corporation Revision 1.1 – May, 2016 N8146-92 N8147-28 N8146-93 31 SYSTEM CONFIGURATION GUIDE – NEC Express5800/T120g NOTE: Filter Replacement Sensor is supported on the Windows and Red Hat Enterprise Linux systems. Dust Proof Bezel is supported on the tower configuration only. 9.5 Medium and Cartridge Category Product Name Drive supported Part Number RDX RDX Cartridge (500GB) N8151-125 N8153-02 RDX Cartridge (1TB) N8151-125 N8153-03 RDX Cartridge (2TB) N8151-125 N8153-09 RDX Cartridge (3TB) N8151-125 N8153-10 NEC Corporation Revision 1.1 – May, 2016 32 SYSTEM CONFIGURATION GUIDE – NEC Express5800/T120g References Boot Mode Setting The server supports Legacy mode and UEFI mode (default) as an OS Boot Mode. See the table below for the Boot Mode and X2APIC setting for each Operating System. As the default settings at the factory, UEFI mode is set as OS Boot mode and X2APIC is enabled. Refer to the User’s Guide and change the settings before installing an Operating System requiring Legacy Mode. Operating System Supported Boot Mode Supported X2APIC Setting Windows Server 2008 R2 (x64) Legacy Disabled Windows Server 2012 UEFI Enabled Windows Server 2012 R2 UEFI Enabled Red Hat Enterprise Linux 6(x86_64) UEFI Enabled Red Hat Enterprise Linux 7 UEFI Enabled VMware ESXi 5.5 Update3 Legacy Disabled VMware ESXi 6.0 Update1 Legacy Disabled NEC Corporation Revision 1.1 – May, 2016 33 SYSTEM CONFIGURATION GUIDE – NEC Express5800/T120g Server Management The EXPRESSSCOPE Engine 3, integrated into the server, provides superior remote control and system management features listed in the table below. Standard Hardware monitoring With Remote KVM and Media License kit Temperature/voltage/power/RAID/ standard LANfan /degeneration (memory/hard drive) Hardware configuration information collection Hardware event log collection 1 1 Boot monitoring BIOS/POST stall, Booting, OS stall, shutdown Alerting HW error, Boot error , and OS panic (by SNMP, E-Mail) Remote KVM (via LAN) POST/BIOS setup, ROM utility Remote control (via LAN) 2 2, 3, 4 CUI-based screen (OS console) 2, 4 GUI-based screen (OS console) - Remote console recording function - Manual Video recording - Automatic video recording - Remote reset/power on-off/ dump Remote power capping BIOS/BMC FW update Remote BIOS setup(partial configuration only) Panic screen, Boot screen 1 1 1 OS shutdown Remote media (CD/DVD/FD/USB) - CLP (Command Line Protocol) (DMTF compliant) Remote control via Web browser (multi user login at the same time) Scheduling (without UPS) BIOS setting by using XML file Maintenance EXPRESSSCOPE® Profile key (Backup/restore BIOS/BMC setup information) Others Set automatic IP address via DNS/DHCP LDAP/Active Directory verification/user control Clock synchronization of main unit and the RTC Access log collection IPMI 2.0 2.0 IPv6(Web console/CLP only) 1 2 3 4 1 1 The feature is not supported on VMware ESXi systems. The optional serial port is not available for the feature. Monitoring boot screens is not supported on VMware systems. In VMware systems, only the direct console user interface is supported. NEC Corporation Revision 1.1 – May, 2016 34 SYSTEM CONFIGURATION GUIDE – NEC Express5800/T120g Endurance of SSD The 2.5-inch SAS/SATA SSDs have limited lifetime, which can only be written a limited number of times before it fails. The warranty period of SSD is the stated period of warranty or until the total bytes of written value (PBW) exceeds the limit value, whichever occurs first. It is recommended to check the total bytes of written value periodically. Refer to the table below for the write endurance (PBW and DWPD), warranty period and monitoring tool. SSD Lifetime Part Number Product Name PBW DWPD Period Monitoring Tool N8150-721 200GB Hot Plug 2.5-inch SAS SSD 3.6PBW 10 Times 3 Years N8150-722 400GB Hot Plug 2.5-inch SAS SSD 7.3PBW 10 Times 3 Years Universal RAID Utility, EXPRESSBUILDER (System Test and Diagnostics) SAS SSD SATA SSD (Middle Endurance) N8150-725 200GB Hot Plug 2.5-inch SATA SSD 3.6PBW 10 Times 3 Years N8150-726 400GB Hot Plug 2.5-inch SATA SSD 7.3PBW 10 Times 3 Years N8150-727 800GB Hot Plug 2.5-inch SATA SSD 14.6PBW 10 Times 3 Years SATA SSD (Value Endurance) N8150-732 200GB Hot Plug 2.5-inch SATA SSD 1.1PBW 3 Times 3 Years N8150-733 400GB Hot Plug 2.5-inch SATA SSD 3.0PBW 3 Times 3 Years N8150-734 800GB Hot Plug 2.5-inch SATA SSD 5.3PBW 3 Times 3 Years N8150-735 1.6TB Hot Plug 2.5-inch SATA SSD 10.7PBW 3 Times 3 Years PBW(Peta-Bytes Write): Total amount of data that can be written into the SSD. 1PB=1,000TB. DWPD(Drive Writes per Day): Rewrite capacity of the SSD per day. Check the lifetime of SSD by monitoring tool regularly. It is recommended to replace the SSD before it reaches its end of life. For repurchase, please contact your sales representative. For detailed operating methods of monitoring tool, refer to the User’s Guide. NEC Corporation Revision 1.1 – May, 2016 35 SYSTEM CONFIGURATION GUIDE – NEC Express5800/T120g OS Support Matrix for PCI Cards and Embedded Controllers ESXi 5.5 ESXi 6.0 RHEL 6 x64 RHEL 7 WS 2008 R2 WS 2012 WS 2012 R2 Part number Product Name - Embedded SATA non-RAID Controller - Embedded SATA RAID Controller - - Embedded 1GbE NIC N8103-176 RAID Controller (1 GB, RAID 0/1) N8103-177 RAID Controller (1 GB, RAID 0/1/5/6) N8103-178 RAID Controller (2 GB, RAID 0/1/5/6) N8103-186 SAS Expander Card N8103-179 RAID Controller (2 GB, RAID 0/1/5/6) N8190-158A Fibre Channel Controller (2ch) N8190-157A Fibre Channel Controller N8104-157 Dual Port 10GBASE-T Adapter - - N8103-184 SAS Controller - N8190-160 Fibre Channel Controller (2ch) N8190-159 Fibre Channel Controller N8104-153 Dual Port 10GBASE-T Adapter - N8104-149 10GBASE adapter (SFP+/2ch) N8103-142 SAS Controller N8104-152 Quad Port 1000BASE-T Adapter N8104-145 Dual Port 1000BASE-T Adapter - N8104-151 Dual Port 1000BASE-T Adapter N8104-150 1000BASE-T adapter NEC Corporation Revision 1.1 – May, 2016 - - - - - - - 36 SYSTEM CONFIGURATION GUIDE – NEC Express5800/T120g Supported PCI Cards and Installable Slots Slots Priority Part Number Product Name #1 #2 #3 #4 #5 (1) N8103-176 RAID Controller (1 GB, RAID 0/1) (4) (2) (1) (3) - (2) N8103-177 RAID Controller (1 GB, RAID 0/1/5/6) (4) (2) (1) (3) - (3) N8103-178 RAID Controller (2 GB, RAID 0/1/5/6) (4) (2) (1) (3) - (4) N8103-186 SAS Expander Card - - - - (1) (5) N8103-179 RAID Controller (2 GB, RAID 0/1/5/6) (4) (2) (1) (3) - (6) N8190-158A Fibre Channel Controller (2ch) (4) (2) (1) (3) - (7) N8190-157A Fibre Channel Controller (4) (2) (1) (3) - (8) N8104-157 Dual Port 10GBASE-T Adapter (4) (2) (1) (3) - (9) N8103-184 SAS Controller (4) (2) (1) (3) - (10) N8190-160 Fibre Channel Controller (2ch) (4) (2) (1) (3) - (11) N8190-159 Fibre Channel Controller (4) (2) (1) (3) - (12) N8104-153 Dual Port 10GBASE-T Adapter (4) (2) (1) (3) (5) (13) N8104-149 10GBASE adapter (SFP+/2ch) (4) (2) (1) (3) (5) (14) N8103-142 SAS Controller (4) (2) (1) (3) (5) (15) N8104-152 Quad Port 1000BASE-T Adapter (4) (2) (1) (3) (5) (16) N8104-145 Dual Port 1000BASE-T Adapter (4) (2) (1) (3) (5) (17) N8104-151 Dual Port 1000BASE-T Adapter (4) (2) (1) (3) (5) (18) N8104-150 1000BASE-T adapter (4) (2) (1) (3) (5) (19) N8117-01A Serial Port Adapter - - (1) (2) (3) NOTE: The slot #1 is available in a dual-processor system. The number between parentheses shows the population priority (recommendation). For example, install N8103-176 (1) in the slot #3, N8190-160 (10) in the slot #2 and N8104-153 (12) in the slot #4 when you have those cards. For VMware ESXi 5.5, there are some limitations as follows: - When any of N8104-149/-153/-157 is installed, N8104-152 cannot be installed and the number of installable N8104-150/-151 is limited up to one. - Up to two cards of N8104-152 can be installed. - Up to four cards of N8104-150/-151 can be installed. - Up to three cards of N8104-149/-153/-157 can be installed. - Up to four cards of N8190-158A/N8190-160/N8103-184 can be installed. - When the above four groups are mixed (N8104-152, N8104-150/-151, N8104-149/-153/-157, and N8190-158A/N8190-160/N8103-184), the number of installable cards among them becomes up to three. - When configured with Xeon E5-2660 v4/2690 v4/2697 v4, up to one card of N8103-176/-177/-178/-179 can be installed - When configured with Xeon E5-2650 v4, up to two cards of N8103-176/-177/-178/-179 can be installed For VMware ESXi 6.0, there are some limitations as follows: - When any of N8104-149/-153/-157 is installed, N8104-152 cannot be installed and the number of installable N8104-150/-151 is limited up to one. For the configuration limitation for VMware ESXi, refer to the following documents. VMware ESXi5.1 https://www.vmware.com/pdf/vsphere5/r51/vsphere-51-configuration-maximums.pdf VMware ESXi5.5 https://www.vmware.com/pdf/vsphere5/r55/vsphere-55-configuration-maximums.pdf VMware ESXi6.0 NEC Corporation Revision 1.1 – May, 2016 37 SYSTEM CONFIGURATION GUIDE – NEC Express5800/T120g https://www.vmware.com/pdf/vsphere6/r60/vsphere-60-configuration-maximums.pdf Copyright Notice and Liability Disclaimer The information contained herein is subject to change without notice. Microsoft and Windows Server are either registered trademarks or trademarks of Microsoft Corporation in the United States and/or other countries Intel and Xeon are registered trademarks or trademarks of Intel Corporation or its subsidiaries in the United States and other countries. Linux is a trademark of Linus Torvalds. Red Hat is a registered trademark of Red Hat, Inc. in the U.S. All other products, brands, or trade names used in this document are trademarks or registered trademarks of their respective holders. NEC shall not be liable for technical or editorial errors or omissions contained herein. For hard drive capacity measurements, 1 GB = 1 billion bytes. Actual formatted capacity is less. NEC Corporation Revision 1.1 – May, 2016 38 SYSTEM CONFIGURATION GUIDE – NEC Express5800/T120g Revision History Revision Date Description 1.1 May 17, 2016 Others: Added DVD read speed information 1.0 April 25, 2016 Initial release NEC Corporation Revision 1.1 – May, 2016 39