NEC Express5800/T110h System Configuration Guide Introduction This document contains product and configuration information that will enable you to configure your system. The guide will ensure fast and proper configuration of your NEC Express5800 server. May 17, 2016 Revision 2.1 NEC Corporation SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110h Contents TECHNICAL SPECIFICATION ........................................................................................ 3 Key Features .......................................................................................................................................... 3 Specification .......................................................................................................................................... 3 EXTERNAL VIEWS ......................................................................................................... 7 Front View .............................................................................................................................................. 7 Rear Views ............................................................................................................................................. 8 Dimensions (mm) .................................................................................................................................. 9 CONFIGURATION DIAGRAM ....................................................................................... 11 Expansion Slots .................................................................................................................................. 11 SERVER CONFIGURATION ......................................................................................... 12 1 2 3 4 5 6 7 8 9 Base Models ................................................................................................................................. 12 Processor ..................................................................................................................................... 12 Memory ......................................................................................................................................... 13 Maximum Available Memory .......................................................................................................... 13 Internal Hard Disk Drives ............................................................................................................ 14 4.1 RAID Configuration .............................................................................................................. 14 4.2 Required Components for RAID Configuration ................................................................... 17 4.3 Supported Drives ................................................................................................................. 22 Optical Drive ................................................................................................................................. 27 Internal RDX / LTO Drives ........................................................................................................... 28 6.1 RDX/LTO Drive Selection .................................................................................................... 28 6.2 RDX/LTO Configuration ....................................................................................................... 28 PCI Card ........................................................................................................................................ 29 7.1 Network Interface Controller ................................................................................................ 29 7.2 SAS Controller ..................................................................................................................... 30 7.3 Serial Port Adapter .............................................................................................................. 30 Other Add-in Components .......................................................................................................... 31 8.1 Fan Kit ................................................................................................................................. 31 8.2 Trusted Platform Module Kit ................................................................................................ 31 8.3 Internal Flash Memory ......................................................................................................... 31 8.4 High Temperature Support Option ....................................................................................... 31 8.5 Flash FDD............................................................................................................................ 32 8.6 Input Devices ....................................................................................................................... 32 Add-on Components ................................................................................................................... 33 9.1 Server Management License............................................................................................... 33 9.2 Dust Proof Kit ...................................................................................................................... 33 9.3 Rack Conversion Kit ............................................................................................................ 33 9.4 Medium and Cartridge ......................................................................................................... 33 REFERENCES............................................................................................................... 34 Boot Mode Setting .............................................................................................................................. 34 Server Management ............................................................................................................................ 35 Endurance of SSD ............................................................................................................................... 36 OS Support Matrix for PCI Cards and Embedded Controllers ....................................................... 37 Supported PCI cards and Installable Slots....................................................................................... 37 Copyright Notice and Liability Disclaimer ........................................................................................ 39 NEC Corporation Revision 2.1 – May, 2016 2 SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110h REVISION HISTORY ..................................................................................................... 40 Technical Specification Key Features High performance with the latest Intel® Xeon® processor E3-1200 v5 processor family Up to 64 GB of high speed DDR4 memory 4 PCIe gen3 slots for various needs and future expansion Agent-less management with improved EXPRESSCOPE Engine 3 Wide range of operating ambient temperature from 5 to 48°C (41 to 118°F) Specification (1 / 2) Model T110h Part Number Processor N8100-2332F, N8100-2333F Type Intel® Celeron® processor G3900 Intel® Pentium® processor G4400 Intel® Core™ i3-6300 processor Intel® Xeon® processor E3-1220 v5 Clock speed 2.80 GHz 3.30 GHz 3.80 GHz 3.00 GHz Number of Processors 1 Cache 2 MB 3 MB 4 MB 8 MB Cores and Threads 2C / 2T 2C / 4T 4C / 4T Chipset Memory Internal Storage Intel® C236 Chipset Type DDR4-2133 ECC Unbuffered DIMM Standard Capacity 0 GB Maximum Capacity 64 GB (4 x 16 GB) Standard Capacity 0 GB Maximum Capacity 24 TB (4 x 6 TB) Disk Controller SATA : 6 Gb/s (Integrated) SATA/SAS : 6/12 Gb/s (Optional) RAID SATA : RAID 0/1/10 (Standard ) SATA/SAS : RAID 0/1/5/6/10/50/60 (Optional) Hot Plug Supported with hot plug drive bay Optical Disk Drive Optional 5-inch Media Bays 2 Disk Drive Bays Hot plug 2.5-inch drive configuration: 8 Hot plug 3.5-inch drive configuration: 4 Non-hot plug 3.5-inch drive configuration: 4 1 Expansion Slots Video Interfaces NEC Corporation Total: 4 slots available 1 PCIe 3.0 x16 (x16 connector) 1 PCIe 3.0 x4 (x8 connector) 1 PCIe 3.0 x2 (x8 connector) 1 PCIe 3.0 x1 (x8 connector) Controller (VRAM) Integrated in Server Management Controller (32MB) Resolution / Color 1600 x 1200 / 16.7M 2 1 VGA (15-pin mini D-sub,1 rear) 1 to 2 Serial (9-pin mini D-sub, RS232-C, 1 to 2 rear) 6 USB 3.0 (2 front, 4 rear) (plus 1 internal USB 3.0) 2 1000BASE-T LAN connector (RJ-45, 2 rear) Revision 2.1 – May, 2016 3 SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110h Model T110h Interfaces (cont’d) 1 1000BASE-T LAN connector for Management (RJ-45, 1 rear) Server Management EXPRESSSCOPE Engine 3 System Fan Standard Power Supply 1 x 400 Watt 80 PLUS® Gold certified non-hot plug PSU 2 x 460 Watt 80 PLUS® Platinum certified Hot plug PSU 100-240 VAC ± 10% 50 / 60 Hz ± 3 Hz Power Consumption 1 2 3 4 5 (Max. Config, Idling) 115 VA / 114 Watt (Max. Config, Operating) 260 VA / 259 Watt 268 VA / 266 Watt 277 VA / 275 Watt 261 VA / 259 Watt Acoustic Noise Minimum Config. (Sound Pressure Maximum Config. 3 Level) Dimensions (W x D x H ) 27.1 dB Weight (Minimum / Maximum) 11 kg / 19 kg, 24.25 lbs. / 41.88 lbs. Temperature, Relative Humidity (non-condensing) Operating: 5° to 40° C / 41° to 104° F (Standard) or 5° to 48° C / 41° to 118° F (Optional), 20 to 80% Non-Operating: -10° to 55° C / 14° to 131° F, 20 to 80% Regulatory and Safety FCC, c-UL, CE, CB, RoHS, WEEE, BSMI, CCC Operating Systems and Virtualization Software Microsoft® Windows Server® 2008 R2 Standard Microsoft® Windows Server® 2008 R2 Enterprise Microsoft® Windows Server® 2012 Standard Microsoft® Windows Server® 2012 Datacenter Microsoft® Windows Server® 2012 R2 Standard Microsoft® Windows Server® 2012 R2 Datacenter 4 Red Hat Enterprise Linux 6.7 or later (x86_64) 46 Red Hat Enterprise Linux 7.2 or later 5 VMware ESXi 5.5 Update 3 5 VMware ESXi 6.0 Update 1 34.7 dB 175.0 x 469.3 x 367.0mm / 6.8 x 18.5 x 14.4 in Embedded SATA RAID controller is supported only on limited OS. Maximum resolution available via EXPRESSSCOPE Engine 3 remote console is 1280 x 1024 / 65K colors. Noise emission was measured in accordance with ISO 7779, at 25°C. The actual value may vary by the operating environment. For Linux support, contact your sales representative or go to the NEC website at: http://www.nec.com/global/prod/express/linux/index.html VMware ESXi is supported only on Core and Xeon processor systems. (2 / 2) Model T110h Part Number N8100-2332F, N8100-2333F Processor Chipset NEC Corporation Type Intel® Xeon® processor E3-1230 v5 Intel® Xeon® processor E3-1270 v5 Clock speed 3.40 GHz 3.60GHz Number of Processors 1 Cache 8 MB Cores and Threads 4C / 8T Intel® C236 Chipset Revision 2.1 – May, 2016 4 SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110h Model Memory Internal Storage T110h Type DDR4-2133 ECC Unbuffered DIMM Standard Capacity 0 GB Maximum Capacity 64 GB (4 x 16 GB) Standard Capacity 0 GB Maximum Capacity 24 TB (4 x 6 TB) Disk Controller SATA : 6 Gb/s (Integrated) SATA/SAS : 6/12 Gb/s (Optional) RAID SATA : RAID 0/1/10 (Standard ) SATA/SAS : RAID 0/1/5/6/10/50/60 (Optional) Hot Plug Supported with hot plug drive bay Optical Disk Drive Optional 5-inch Media Bays 2 Disk Drive Bays Hot plug 2.5-inch drive configuration: 8 Hot plug 3.5-inch drive configuration: 4 Non-hot plug 3.5-inch drive configuration: 4 1 Expansion Slots Video Total: 4 slots available 1 PCIe 3.0 x16 (x16 connector) 1 PCIe 3.0 x4 (x8 connector) 1 PCIe 3.0 x2 (x8 connector) 1 PCIe 3.0 x1 (x8 connector) Controller (VRAM) Integrated in Server Management Controller (32MB) Resolution / Color 1600 x 1200 / 16.7M 2 Interfaces 1 VGA (15-pin mini D-sub,1 rear) 1 to 2 Serial (9-pin mini D-sub, RS232-C, 1 to 2 rear) 6 USB 3.0 (2 front, 4 rear) (plus 1 internal USB 3.0) 2 1000BASE-T LAN connector (RJ-45, 2 rear) 1 1000BASE-T LAN connector for Management (RJ-45, 1 rear) Server Management EXPRESSSCOPE Engine 3 System Fan Standard Power Supply 1 x 400 Watt 80 PLUS® Gold certified non-hot plug PSU 2 x 460 Watt 80 PLUS® Platinum certified Hot plug PSU 100-240 VAC ± 10% 50 / 60 Hz ± 3 Hz Power Consumption (Max. Config, Idling) 115 VA / 114 Watt (Max. Config, Operating) 295 VA / 293 Watt Acoustic Noise Minimum Config. (Sound Pressure Maximum Config. 3 Level) Dimensions (W x D x H ) 27.1 dB Weight (Minimum / Maximum) 11 kg / 19 kg, 24.25 lbs. / 41.88 lbs. Temperature, Relative Humidity (non-condensing) Operating: 5° to 40° C / 41° to 104° F (Standard) or 5° to 48° C / 41° to 118° F (Optional), 20 to 80% Non-Operating: -10° to 55° C / 14° to 131° F, 20 to 80% Regulatory and Safety FCC, c-UL, CE, CB, RoHS, WEEE, BSMI, CCC Operating Systems and Virtualization Software Microsoft® Windows Server® 2008 R2 Standard Microsoft® Windows Server® 2008 R2 Enterprise Microsoft® Windows Server® 2012 Standard Microsoft® Windows Server® 2012 Datacenter Microsoft® Windows Server® 2012 R2 Standard Microsoft® Windows Server® 2012 R2 Datacenter NEC Corporation 34.7 dB 175.0 x 469.3 x 367.0mm / 6.8 x 18.5 x 14.4 in Revision 2.1 – May, 2016 5 SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110h 1 2 3 4 5 Model T110h Operating Systems and Virtualization Software (cont’d) Red Hat Enterprise Linux 6.7 or later (x86_64) 46 Red Hat Enterprise Linux 7.2 or later 5 VMware ESXi 5.5 Update 3 5 VMware ESXi 6.0 Update 1 4 Embedded SATA RAID controller is supported only on limited OS. Maximum resolution available via EXPRESSSCOPE Engine 3 remote console is 1280 x 1024 / 65K colors. Noise emission was measured in accordance with ISO 7779, at 25°C. The actual value may vary by the operating environment. For Linux support, contact your sales representative or go to the NEC website at: http://www.nec.com/global/prod/express/linux/index.html VMware ESXi is supported only on Core and Xeon processor systems. NEC Corporation Revision 2.1 – May, 2016 6 SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110h External Views Front View K J H F D B L A N O P C E G I Q M With Front bezel Hot Plug 2.5-inch Drive Configuration N N O O P P R R Hot Plug 3.5-inch Drive Configuration Non-hot Plug 3.5-inch Drive Configuration Legend A. Power Button J. USB 3.0 Connectors B. Dump (NMI) Button K. Drive Bay Cover C. BMC Reset Button L. Cover Key D. Power LED M. Stabilizer E. Power Capping LED N. 5.25-inch Media Bay 1 5.25-inch Media Bay 2 F. System Status LED 1 O. G. System Status LED 2 P. Optical Disk Drive H. Global LED 1 Q. 2.5-inch Drive Bay I. Global LED 2 R. 3.5-inch Drive Bay NEC Corporation Revision 2.1 – May, 2016 7 SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110h Rear Views A G G B H C H E D F Hot Plug Power Supply Configuration Non-hot Plug Power Supply Configuration Legend A. Serial Port Connector B. E. Data LAN Connectors VGA Connector F. PCI Slots C. USB Connectors G. AC Inlet D. Management LAN Connector H. Power Supply Unit NEC Corporation Revision 2.1 – May, 2016 8 SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110h Dimensions (mm) Standard Bezel / Non-redundant Power Configuration 175.0 469.3 367.0 487.0 249.0 Standard Bezel / Redundant Power Configuration 175.0 469.3 367.0 498.4 NEC Corporation Revision 2.1 – May, 2016 249.0 9 SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110h Dust Proof Bezel / Non-redundant Power Configuration 492.0 175.0 367.0 249.0 506.7 Dust Proof Bezel / Redundant Power Configuration 492.0 492.0 175.0 367.0 518.2 NEC Corporation Revision 2.1 – May, 2016 249.0 10 SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110h Configuration Diagram Legend: Standard components Minimum required components Expansion Slots Slot #1 Slot #2 Slot #3 Slot #4 Legend #1 PCIe 3.0 x2, x8 connector, Full Height, up to 173mm length #2 PCIe 3.0 x1, x8 connector, Full Height, up to 173mm length #3 PCIe 3.0 x16, x16 connector, Full Height, up to 312mm length #4 PCIe 3.0 x4, x8 connector, Full Height, up to 173mm length NEC Corporation Revision 2.1 – May, 2016 11 SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110h Server Configuration 1 Base Models Product Name / Description Part Number NEC Express5800/T110h no CPU, no RAM, no Drive Cage, no HDD, no Optical Drive, no Keyboard, no Mouse Including: 400 Watt non-hot plug power supply NEC Express5800/T110h no CPU, no RAM, no Drive Cage, no HDD, no Optical Drive, no Keyboard, no Mouse Including: 2x 460 Watt hot plug power supply N8100-2332F N8100-2333F NOTE: The base model must be ordered with a processor kit, memory, a drive cage, and an optical drive. Keyboard and mouse are not included in the base models. Please order separately if necessary. For Windows Server 2008 R2 installation, EXPRESSBUILDER DVD is required. 2 Processor Available sockets: 1 Category Product Name / Description Part Number Processors Required Celeron G3900 Processor Kit Intel® Celeron ® Processor G3900 (2.8 GHz, 2C/2T, 2 MB) Pentium G4400 Processor Kit Intel® Pentium ® Processor G4400 (3.3 GHz, 2C/2T, 3 MB) Core i3-6300 Processor Kit Intel® Core™ i3-6300 Processor (3.8 GHz, 2C/4T, 4 MB) Xeon E3-1220 v5 Processor Kit Intel® Xeon ® Processor E3-1220 v5 (3.0 GHz, 4C/4T, 8 MB) Xeon E3-1230 v5 Processor Kit Intel® Xeon ® Processor E3-1230 v5 (3.4 GHz, 4C/8T, 8 MB) Xeon E3-1270 v5 Processor Kit Intel® Xeon ® Processor E3-1270 v5 (3.6 GHz, 4C/8T, 8 MB) N8101-938F N8101-939F N8101-940F N8101-941F N8101-942F N8101-945F NOTE: One processor kit from above must be installed. VMware ESXi is not supported on Celeron processor systems or Pentium processor systems. NEC Corporation Revision 2.1 – May, 2016 12 SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110h 3 Memory Available slots: 4 Product Name / Description Part Number 4GB DDR4-2133 UNB Memory Kit 1 x 4GB Unbuffered ECC DIMM, DDR4-2133 8GB DDR4-2133 UNB Memory Kit 1 x 8GB Unbuffered ECC DIMM, DDR4-2133 16GB DDR4-2133 UNB Memory Kit 1 x 16GB Unbuffered ECC DIMM, DDR4-2133 N8102-656F N8102-657F N8102-658F NOTE: Minimum one memory kit must be installed. It is recommended to install memory kits in pairs of two identical DIMMs for dual-channel symmetric memory configurations to increase memory transfer speed. The memory requirement for installing VMware ESXi™ are below: - VMware ESXi 5.5 : at least 5 GB - VMware ESXi 6.0 : at least 5 GB Maximum Available Memory See the table below for the maximum memory size that you can actually use on your system. Maximum Memory Size Supported by Operating Systems 1 32 GB 32 GB 2 TB 64 GB Microsoft Windows Server 2012 Standard 1 Microsoft Windows Server 2012 Datacenter 1 Microsoft Windows Server 2012 R2 Standard 1 Microsoft Windows Server 2012 R2 Datacenter 4 TB 64 GB Red Hat Enterprise Linux 6 (x86_64) Red Hat Enterprise Linux 7 6 TB 64 GB 2 4 TB 64 GB 6TB 64 GB Microsoft Windows Server 2008 R2 Standard Microsoft Windows Server 2008 R2 Enterprise 1 VMware ESXi 5.5 VMware ESXi 6 1 2 3 Maximum Available Memory 3 1 The maximum available memory size of Hyper-V systems are below: - Windows Server 2008 R2 Standard : 32 GB - Windows Server 2008 R2 Enterprise : 1TB - Windows Server 2012 and Windows Server 2012 R2 : 4 TB Up to 1TB of main memory is available to each virtual machine. Up to 4TB of main memory is available to each virtual machine. NEC Corporation Revision 2.1 – May, 2016 13 SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110h 4 Internal Hard Disk Drives 4.1 RAID Configuration Refer to the section in accordance with your disk form factor and RAID configuration Operating System Supported RAID configuration RAID and Cache Windows Server 2008 R2 VMware ESXi 5.5 VMware ESXi 6 KVM in Red Hat Enterprise Linux 6 (x86_64) Windows Server 2012 Windows Server 2012 R2 Red Hat Enterprise Linux 6 (x86_64) without KVM Red Hat Enterprise Linux 7 Slot 7 Slot 6 Slot 5 Slot 4 Slot 3 Slot 2 Slot 1 2.5-inch Drive Slot 0 4.1.1 Supported HDD/SSD Section Non-RAID (Embedded SATA) 4.2.1 4.3.1 RAID 0/1/10 No Cache 4.2.3 4.3.3 RAID 0/1/10 1GB Cache 4.2.4 RAID 5/6/50/60 1GB Cache 4.2.5 RAID 5/6/50/60 2GB Cache 4.2.6 Non-RAID (Embedded SATA) 4.2.1 4.3.1 RAID 0/1 (Embedded SATA RAID) 4.2.2 4.3.2 RAID 0/1/10 No Cache 4.2.3 4.3.4 RAID 0/1/10 1GB Cache 4.2.4 RAID 5/6/50/60 1GB Cache 4.2.5 RAID 5/6/50/60 2GB Cache 4.2.6 Non-RAID (Embedded SATA) 4.2.1 4.3.1 RAID 0/1/10 No Cache 4.2.3 4.3.4 RAID 0/1/10 1GB Cache 4.2.4 RAID 5/6/50/60 1GB Cache 4.2.5 RAID 5/6/50/60 2GB Cache 4.2.6 NOTE: Up to four drives can be installed when you choose the Embedded SATA Non-RAID controller. All drives within a RAID array should be of the same capacity and rotation speed. Up to two kinds of drives selected from SAS 10K HDDs, SAS 15K HDDs, SATA HDDs, SAS SSDs, SATA SSDs (ME), and SATA SSDs (VE) can be mixed in a system. Mix configurations of 4Kn sector HDDs and 512n sector HDDs are not supported. To configure a large-capacity RAID array, it is recommended to configure in RAID 6 or RAID 60 in order to minimize the risk of becoming multiple hard drives failure during the RAID rebuilding process. NEC Corporation Revision 2.1 – May, 2016 14 SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110h Operating System Slot 3 Slot 2 Slot 1 Hot plug 3.5-inch Drive Slot 0 4.1.2 Supported RAID configuration RAID and Cache Windows Server 2008 R2 VMware ESXi 5.5 VMware ESXi 6 KVM in Red Hat Enterprise Linux 6 (x86_64) Windows Server 2012 Windows Server 2012 R2 Red Hat Enterprise Linux 6 (x86_64) without KVM Red Hat Enterprise Linux 7 Supported HDD/SSD Section Non-RAID (Embedded SATA) 4.2.7 RAID 0/1/10 No Cache 4.2.9 RAID 0/1/10 1GB Cache 4.2.10 RAID 5/6/50/60 1GB Cache 4.2.11 RAID 5/6/50/60 2GB Cache 4.2.12 Non-RAID (Embedded SATA) 4.2.7 RAID 0/1 (Embedded SATA RAID) 4.2.8 RAID 0/1/10 No Cache 4.2.9 RAID 0/1/10 1GB Cache 4.2.10 RAID 5/6/50/60 1GB Cache 4.2.11 RAID 5/6/50/60 2GB Cache 4.2.12 Non-RAID (Embedded SATA) 4.2.7 RAID 0/1/10 No Cache 4.2.9 RAID 0/1/10 1GB Cache 4.2.10 RAID 5/6/50/60 1GB Cache 4.2.11 RAID 5/6/50/60 2GB Cache 4.2.12 4.3.5 4.3.6 4.3.6 NOTE: All hard drives within a RAID array should be of the same capacity and rotation speed. NEC Corporation Revision 2.1 – May, 2016 15 SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110h Operating System Slot 3 Slot 2 Slot 1 Non-hot plug 3.5-inch Drive Slot 0 4.1.3 Supported RAID configuration RAID and Cache Windows Server 2008 R2 VMware ESXi 5.5 VMware ESXi 6 KVM in Red Hat Enterprise Linux 6 (x86_64) Windows Server 2012 Windows Server 2012 R2 Red Hat Enterprise Linux 6 (x86_64) without KVM Red Hat Enterprise Linux 7 Supported HDD/SSD Section Non-RAID (Embedded SATA) 4.2.13 RAID 0/1/10 No Cache 4.2.15 RAID 0/1/10 1GB Cache 4.2.16 RAID 5/6/50/60 1GB Cache 4.2.17 RAID 5/6/50/60 2GB Cache 4.2.18 Non-RAID (Embedded SATA) 4.2.13 RAID 0/1 (Embedded SATA RAID) 4.2.14 RAID 0/1/10 No Cache 4.2.15 RAID 0/1/10 1GB Cache 4.2.16 RAID 5/6/50/60 1GB Cache 4.2.17 RAID 5/6/50/60 2GB Cache 4.2.18 Non-RAID (Embedded SATA) 4.2.13 RAID 0/1/10 No Cache 4.2.15 RAID 0/1/10 1GB Cache 4.2.16 RAID 5/6/50/60 1GB Cache 4.2.17 RAID 5/6/50/60 2GB Cache 4.2.18 4.3.7 4.3.8 4.3.8 NOTE: All hard drives within a RAID array should be of the same capacity and rotation speed. NEC Corporation Revision 2.1 – May, 2016 16 SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110h 4.2 Required Components for RAID Configuration 4.2.1 Embedded SATA Non-RAID Controller for 2.5-inch Drives Category Product Name / Description Part Number Storage Controller Embedded SATA Controller 4 x 6Gb/s SATA Internal SATA Cable 1 x Mini SAS HD to 1 x Mini SAS HD (Standard) 2.5-inch Hot Plug Drive Cage Kit 8 x 2.5-inch hot plug hard drive bays N8154-80F Cable Drive Cage Required (Included in the Drive Cage) NOTE Hot plug insertion/removal is not supported with the embedded SATA Non-RAID controller. 4.2.2 Embedded SATA RAID Controller for 2.5-inch Drives Category Product Name / Description Part Number Storage Controller Embedded SATA Controller 4 x 6Gb/s SATA, RAID0/1/10 capable Internal SATA Cable 1 x Mini SAS HD to 1 x Mini SAS HD (Standard) 2.5-inch Drive Cage 8 x 2.5-inch hot plug drive bays N8154-80F Cable Drive Cage Required (Included in the Drive Cage) NOTE All hard drives within a RAID array should be of the same capacity. 4.2.3 RAID 0/1 Controller without Cache for 2.5-inch Drives Category Product Name / Description Part Number Storage Controller Required RAID Controller (RAID 0/1) Avago(LSI) MegaRAID SAS 9341-8i RAID0/1/10, no memory cache, Int. 8, PCIe 3.0(x8), SAS 12Gb/s, SATA 6Gb/s Internal SATA Cable 1 x Mini SAS HD to 1 x Mini SAS HD N8103-188 Internal SAS/SATA Cable 1 x Mini SAS HD to 1 x Mini SAS HD, for 5th - 8th hard drives 2.5-inch Drive Cage 8 x 2.5-inch hot plug drive bays K410-340(00) Cable Drive Cage Required (Included in the Drive Cage) N8154-80F NOTE: All drives within a RAID array should be of the same type, capacity and rotation speed.. 4.2.4 RAID 0/1 Controller with 1 GB Cache for 2.5-inch Drives Category Product Name / Description Part Number Storage Controller Required RAID Controller (1GB, RAID 0/1) Avago(LSI) MegaRAID SAS 9362-8i RAID0/1/10, 1GB, Int. 8, PCIe 3.0(x8), SAS 12Gb/s, SATA 6Gb/s Flash Backup Unit for Avago(LSI) MegaRAID SAS 9362-8i 500mm Cable for Flash Backup Unit included N8103-176 Flash Backup Recommended NEC Corporation Revision 2.1 – May, 2016 N8103-180 17 SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110h Cable Drive Cage Required Internal SAS/SATA Cable 1 x Mini SAS HD to 1 x Mini SAS HD (Included in the Drive Cage) Internal SAS/SATA Cable 1 x Mini SAS HD to 1 x Mini SAS HD, for 5th - 8th hard drives 2.5-inch Drive Cage 8 x 2.5-inch hot plug drive bays K410-340(00) N8154-80F NOTE: All drives within a RAID array should be of the same type, capacity and rotation speed. Up to two kinds of drives selected from SAS 10K HDDs, SAS 15K HDDs, SATA HDDs, SAS SSDs, SATA SSDs (ME), and SATA SSDs (VE) can be mixed in a system. 4.2.5 RAID 5/6 Controller with 1 GB Cache for 2.5-inch Drives Category Product Name / Description Part Number Storage Controller Required RAID Controller (1GB, RAID 0/1/5/6) Avago(LSI) MegaRAID SAS 9362-8i RAID0/1/5/6/10/50/60, 1GB, Int. 8, PCIe 3.0(x8), SAS 12Gb/s, SATA 6Gb/s Flash Backup Unit for Avago(LSI) MegaRAID SAS 9362-8i 500mm Cable for Flash Backup Unit included Internal SAS/SATA Cable 1 x Mini SAS HD to 1 x Mini SAS HD N8103-177 Internal SAS/SATA Cable 1 x Mini SAS HD to 1 x Mini SAS HD, for 5th - 8th hard drives 2.5-inch Drive Cage 8 x 2.5-inch hot plug drive bays K410-340(00) Flash Backup Recommended Cable Drive Cage Required N8103-180 (Included in the Drive Cage) N8154-80F NOTE: All drives within a RAID array should be of the same type, capacity and rotation speed. Up to two kinds of drives selected from SAS 10K HDDs, SAS 15K HDDs, SATA HDDs, SAS SSDs, SATA SSDs (ME), and SATA SSDs (VE) can be mixed in a system. 4.2.6 RAID 5/6 Controller with 2 GB Cache for 2.5-inch Drives Category Product Name / Description Part Number Storage Controller Required RAID Controller (2GB, RAID 0/1/5/6) Avago(LSI) MegaRAID SAS 9362-8i RAID0/1/5/6/10/50/60, 2 GB, Int. 8, PCIe 3.0(x8), SAS 12Gb/s, SATA 6Gb/s Flash Backup Unit for Avago(LSI) MegaRAID SAS 9362-8i 500mm Cable for Flash Backup Unit included Internal SAS/SATA Cable 1 x Mini SAS HD to 1 x Mini SAS HD N8103-178 Internal SAS/SATA Cable 1 x Mini SAS HD to 1 x Mini SAS HD, for 5th - 8th hard drives 2.5-inch Drive Cage 8 x 2.5-inch hot plug drive bays K410-340(00) Flash Backup Recommended Cable Drive Cage Required N8103-180 (Included in the Drive Cage) N8154-80F NOTE: All drives within a RAID array should be of the same type, capacity and rotation speed. Up to two kinds of drives selected from SAS 10K HDDs, SAS 15K HDDs, SATA HDDs, SAS SSDs, SATA SSDs (ME), and SATA SSDs (VE) can be mixed in a system. NEC Corporation Revision 2.1 – May, 2016 18 SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110h 4.2.7 Embedded SATA Non-RAID Controller for 3.5-inch Drives Category Product Name / Description Part Number Storage Controller Embedded SATA Controller 4 x 6Gb/s SATA Internal SAS/SATA Cable 1 x Mini SAS HD to 1 x Mini SAS HD 3.5-inch Drive Cage 4 x 3.5-inch hot plug drive bays (Standard) Cable Drive Cage Required (Included in the Drive Cage) N8154-79F NOTE Hot plug insertion/removal is not supported with the embedded SATA Non-RAID controller. 4.2.8 Embedded SATA RAID Controller for 3.5-inch Drives Category Product Name / Description Part Number Storage Controller Embedded SATA Controller 4 x 6Gb/s SATA, RAID0/1/10 capable Internal SAS/SATA Cable 1 x Mini SAS HD to 1 x Mini SAS HD 3.5-inch Drive Cage 4 x 3.5-inch hot plug drive bays (Standard) Cable Drive Cage Required (Included in the Drive Cage) N8154-79F NOTE: All hard drives within a RAID array should be of the same capacity. Embedded SATA RAID Controller does not support RAID 10 configured with 2TB or more HDDs. 4.2.9 RAID 0/1 Controller without Cache for 3.5-inch Drives Category Product Name / Description Part Number Storage Controller Required RAID Controller (RAID 0/1) Avago(LSI) MegaRAID SAS 9341-8i RAID0/1/10, no memory cache, Int. 8, PCIe 3.0(x8), SAS 12Gb/s, SATA 6Gb/s Internal SAS/SATA Cable 1 x Mini SAS HD to 1 x Mini SAS HD 3.5-inch Drive Cage 4 x 3.5-inch hot plug drive bays N8103-188 Cable Drive Cage Required (Included in the Drive Cage) N8154-79F NOTE: All hard drives within a RAID array should be of the same capacity. 4.2.10 RAID 0/1 Controller with 1 GB Cache for 3.5-inch Drives Category Product Name / Description Part Number Storage Controller Required RAID Controller (1GB, RAID 0/1) Avago(LSI) MegaRAID SAS 9362-8i RAID0/1/10, 1GB, Int. 8, PCIe 3.0(x8), SAS 12Gb/s, SATA 6Gb/s Flash Backup Unit for Avago(LSI) MegaRAID SAS 9362-8i 500mm Cable for Flash Backup Unit included Internal SAS/SATA Cable 1 x Mini SAS HD to 1 x Mini SAS HD 3.5-inch Drive Cage 4 x 3.5-inch hot plug drive bays N8103-176 Flash Backup Recommended Cable Drive Cage Required N8103-180 (Included in the Drive Cage) N8154-79F NOTE: All hard drives within a RAID array should be of the same capacity. NEC Corporation Revision 2.1 – May, 2016 19 SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110h 4.2.11 RAID 5/6 Controller with 1 GB Cache for 3.5-inch Drives Category Product Name / Description Part Number Storage Controller Required RAID Controller (1GB, RAID 0/1/5/6) Avago(LSI) MegaRAID SAS 9362-8i RAID0/1/5/6/10/50/60, 1GB, Int. 8, PCIe 3.0(x8), SAS 12Gb/s, SATA 6Gb/s Flash Backup Unit for Avago(LSI) MegaRAID SAS 9362-8i 500mm Cable for Flash Backup Unit included Internal SAS/SATA Cable 1 x Mini SAS HD to 1 x Mini SAS HD 3.5-inch Drive Cage 4 x 3.5-inch hot plug drive bays N8103-177 Flash Backup Recommended Cable Drive Cage Required N8103-180 (Included in the Drive Cage) N8154-79F NOTE All hard drives within a RAID array should be of the same capacity. 4.2.12 RAID 5/6 Controller with 2 GB Cache for 3.5-inch Drives Category Product Name / Description Part Number Storage Controller Required RAID Controller (2GB, RAID 0/1/5/6) Avago(LSI) MegaRAID SAS 9362-8i RAID0/1/5/6/10/50/60, 2 GB, Int. 8, PCIe 3.0(x8), SAS 12Gb/s, SATA 6Gb/s Flash Backup Unit for Avago(LSI) MegaRAID SAS 9362-8i 500mm Cable for Flash Backup Unit included Internal SAS/SATA Cable 1 x Mini SAS HD to 1 x Mini SAS HD 3.5-inch Drive Cage 4 x 3.5-inch hot plug drive bays N8103-178 Flash Backup Recommended Cable Drive Cage Required N8103-180 (Included in the Drive Cage) N8154-79F NOTE All hard drives within a RAID array should be of the same capacity. 4.2.13 Embedded SATA Non-RAID Controller for Non-hot plug 3.5-inch Drives Category Product Name / Description Part Number Storage Controller Embedded SATA Controller 4 x 6Gb/s SATA Internal SAS/SATA Cable 1 x Mini SAS HD to 4 x Single SATA 3.5-inch Drive Cage 4 x 3.5-inch non-hot plug drive bays (Standard) Cable Drive Cage Required (Included in the Drive Cage) N8154-81F 4.2.14 Embedded SATA RAID Controller for Non-hot plug 3.5-inch Drives Category Product Name / Description Part Number Storage Controller Embedded SATA Controller 4 x 6Gb/s SATA, RAID0/1/10 capable Internal SAS/SATA Cable 1 x Mini SAS HD to 4 x Single SATA 3.5-inch Drive Cage 4 x 3.5-inch non-hot plug drive bays (Standard) Cable Drive Cage Required (Included in the Drive Cage) N8154-81F NOTE: NEC Corporation Revision 2.1 – May, 2016 20 SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110h All hard drives within a RAID array should be of the same capacity. Embedded SATA RAID Controller does not support RAID 10 configured with 2TB or more HDDs. 4.2.15 RAID 0/1 Controller without Cache for Non-hot plug 3.5-inch Drives Category Product Name / Description Part Number Storage Controller Required RAID Controller (RAID 0/1) Avago(LSI) MegaRAID SAS 9341-8i RAID0/1/10, no memory cache, Int. 8, PCIe 3.0(x8), SAS 12Gb/s, SATA 6Gb/s RAID LED Cable N8103-188 Internal SAS/SATA Cable 1 x Mini SAS HD to 4 x Single SATA 3.5-inch Drive Cage 4 x 3.5-inch non-hot plug drive bays (Included in the Drive Cage) Cable Required Cable Drive Cage Required K410-293(00) N8154-81F NOTE: All hard drives within a RAID array should be of the same capacity. 4.2.16 RAID 0/1 Controller with 1 GB Cache for Non-hot plug 3.5-inch Drives Category Product Name / Description Part Number Storage Controller Required RAID Controller (1GB, RAID 0/1) Avago(LSI) MegaRAID SAS 9362-8i RAID0/1/10, 1GB, Int. 8, PCIe 3.0(x8), SAS 12Gb/s, SATA 6Gb/s Flash Backup Unit for Avago(LSI) MegaRAID SAS 9362-8i 500mm Cable for Flash Backup Unit included RAID LED Cable N8103-176 Internal SAS/SATA Cable 1 x Mini SAS HD to 4 x Single SATA 3.5-inch Drive Cage 4 x 3.5-inch non-hot plug drive bays (Included in the Drive Cage) Flash Backup Recommended Cable Required Cable Drive Cage Required N8103-180 K410-293(00) N8154-81F NOTE: All hard drives within a RAID array should be of the same capacity. 4.2.17 RAID 5/6 Controller with 1 GB Cache for Non-hot plug 3.5-inch Drives Category Product Name / Description Part Number Storage Controller Required RAID Controller (1GB, RAID 0/1) Avago(LSI) MegaRAID SAS 9362-8i RAID0/1/10, 1GB, Int. 8, PCIe 3.0(x8), SAS 12Gb/s, SATA 6Gb/s Flash Backup Unit for Avago(LSI) MegaRAID SAS 9362-8i 500mm Cable for Flash Backup Unit included RAID LED Cable N8103-177 Internal SAS/SATA Cable 1 x Mini SAS HD to 4 x Single SATA 3.5-inch Drive Cage 4 x 3.5-inch non-hot plug drive bays (Included in the Drive Cage) Flash Backup Recommended Cable Required Cable Drive Cage Required N8103-180 K410-293(00) N8154-81F NOTE: All hard drives within a RAID array should be of the same capacity. NEC Corporation Revision 2.1 – May, 2016 21 SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110h 4.2.18 RAID 5/6 Controller with 2 GB Cache for Non-hot plug 3.5-inch Drives Category Product Name / Description Part Number Storage Controller Required RAID Controller (2GB, RAID 0/1/5/6) Avago(LSI) MegaRAID SAS 9362-8i RAID0/1/5/6/10/50/60, 2 GB, Int. 8, PCIe 3.0(x8), SAS 12Gb/s, SATA 6Gb/s Flash Backup Unit for Avago(LSI) MegaRAID SAS 9362-8i 500mm Cable for Flash Backup Unit included RAID LED Cable N8103-178 Internal SAS/SATA Cable 1 x Mini SAS HD to 4 x Single SATA 3.5-inch Drive Cage 4 x 3.5-inch non-hot plug drive bays (Included in the Drive Cage) Flash Backup Recommended Cable Required Cable Drive Cage Required N8103-180 K410-293(00) N8154-81F NOTE: All hard drives within a RAID array should be of the same capacity. 4.3 Supported Drives 4.3.1 2.5-inch Drives (1) Category Drive 4 slots available 4.3.2 SATA HDD (512n) SATA HDD (512n) SATA SSD (ME) SATA SSD (VE) NEC Corporation Part Number 250GB 7.2K Hot Plug 2.5-inch SATA HDD 1 x 250 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm, 512n sector 500GB 7.2K Hot Plug 2.5-inch SATA HDD 1 x 500 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm, 512n sector 1TB 7.2K Hot Plug 2.5-inch SATA HDD 1 x 1 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm, 512n sector 2TB 7.2K Hot Plug 2.5-inch SATA HDD 1 x 2 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm, 512n sector N8150-487 N8150-488 N8150-489 N8150-527 2.5-inch Drives (2) Category Drive 4 slots available Product Name / Description Product Name / Description Part Number 250GB 7.2K Hot Plug 2.5-inch SATA HDD 1 x 250 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm, 512n sector 500GB 7.2K Hot Plug 2.5-inch SATA HDD 1 x 500 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm, 512n sector 1TB 7.2K Hot Plug 2.5-inch SATA HDD 1 x 1 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm, 512n sector 2TB 7.2K Hot Plug 2.5-inch SATA HDD 1 x 2 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm, 512n sector 200GB Hot Plug 2.5-inch SATA SSD 1 x 200 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, ME 400GB Hot Plug 2.5-inch SATA SSD 1 x 400 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, ME 800GB Hot Plug 2.5-inch SATA SSD 1 x 800 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, ME 200GB Hot Plug 2.5-inch SATA SSD 1 x 200 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, VE 400GB Hot Plug 2.5-inch SATA SSD 1 x 400 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, VE 800GB Hot Plug 2.5-inch SATA SSD 1 x 800 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, VE N8150-487 Revision 2.1 – May, 2016 N8150-488 N8150-489 N8150-527 N8150-725 N8150-726 N8150-727 N8150-732 N8150-733 N8150-734 22 SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110h 1.6TB Hot Plug 2.5-inch SATA SSD 1 x 1.6 TB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, VE 4.3.3 2.5-inch Drives (3) Category Drive 8 slots available N8150-735 SAS HDD (512n) SATA HDD (512n) SAS SSD (eMLC) SATA SSD (ME) SATA SSD (VE) Product Name / Description Part Number 300GB 10K Hot Plug 2.5-inch SAS HDD 1 x 300 GB SAS HDD, 2.5-inch, 12Gb/s, 10,000 rpm, 512n sector 450GB 10K Hot Plug 2.5-inch SAS HDD 1 x 450 GB SAS HDD, 2.5-inch, 12Gb/s, 10,000 rpm, 512n sector 600GB 10K Hot Plug 2.5-inch SAS HDD 1 x 600 GB SAS HDD, 2.5-inch, 12Gb/s, 10,000 rpm, 512n sector 900GB 10K Hot Plug 2.5-inch SAS HDD 1 x 900 GB SAS HDD, 2.5-inch, 12Gb/s, 10,000 rpm, 512n sector 1.2TB 10K Hot Plug 2.5-inch SAS HDD 1 x 1.2TB SAS HDD, 2.5-inch, 12Gb/s, 10,000 rpm, 512n sector 300GB 15K Hot Plug 2.5-inch SAS HDD 1 x 300 GB SAS HDD, 2.5-inch, 12Gb/s, 15,000 rpm, 512n sector 450GB 15K Hot Plug 2.5-inch SAS HDD 1 x 450 GB SAS HDD, 2.5-inch, 12Gb/s, 15,000 rpm, 512n sector 600GB 15K Hot Plug 2.5-inch SAS HDD 1 x 600 GB SAS HDD, 2.5-inch, 12Gb/s, 15,000 rpm, 512n sector 250GB 7.2K Hot Plug 2.5-inch SATA HDD 1 x 250 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm, 512n sector 500GB 7.2K Hot Plug 2.5-inch SATA HDD 1 x 500 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm, 512n sector 1TB 7.2K Hot Plug 2.5-inch SATA HDD 1 x 1 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm, 512n sector 2TB 7.2K Hot Plug 2.5-inch SATA HDD 1 x 2 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm, 512n sector 200GB Hot Plug 2.5-inch SAS SSD 1 x 200 GB SAS SSD, eMLC, 2.5-inch, 12Gb/s, 512n sector 400GB Hot Plug 2.5-inch SAS SSD 1 x 400 GB SAS SSD, eMLC, 2.5-inch, 12Gb/s, 512n sector 200GB Hot Plug 2.5-inch SATA SSD 1 x 200 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, ME 400GB Hot Plug 2.5-inch SATA SSD 1 x 400 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, ME 800GB Hot Plug 2.5-inch SATA SSD 1 x 800 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, ME 200GB Hot Plug 2.5-inch SATA SSD 1 x 200 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, VE 400GB Hot Plug 2.5-inch SATA SSD 1 x 400 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, VE 800GB Hot Plug 2.5-inch SATA SSD 1 x 800 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, VE 1.6TB Hot Plug 2.5-inch SATA SSD 1 x 1.6 TB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, VE N8150-479 N8150-480 N8150-481 N8150-482 N8150-483 N8150-485 N8150-486 N8150-518 N8150-487 N8150-488 N8150-489 N8150-527 N8150-721 N8150-722 N8150-725 N8150-726 N8150-727 N8150-732 N8150-733 N8150-734 N8150-735 NOTE: All hard drives within a RAID array should be of the same capacity. NEC Corporation Revision 2.1 – May, 2016 23 SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110h Up to two kinds of drives selected from SAS 10K HDDs, SAS 15K HDDs, SATA HDDs, SAS SSDs, SATA SSDs (ME), and SATA SSDs (VE) can be mixed in a system. Mix configurations of 4Kn sector HDDs and 512n sector HDDs are not supported. To configure a large-capacity RAID array, it is recommended to configure in RAID 6 or RAID 60 in order to minimize the risk of becoming multiple hard drives failure during the RAID rebuilding process. The 2.5-inch SAS/SATA SSDs have limited lifetime. Refer to Endurance of SSD for details. 4.3.4 2.5-inch Drives (4) Category Drive 8 slots available SAS HDD (512n) SAS HDD (4Kn) SATA HDD (512n) SAS SSD (eMLC) SATA SSD (ME) SATA SSD (VE) Product Name / Description Part Number 300GB 10K Hot Plug 2.5-inch SAS HDD 1 x 300 GB SAS HDD, 2.5-inch, 12Gb/s, 10,000 rpm, 512n sector 450GB 10K Hot Plug 2.5-inch SAS HDD 1 x 450 GB SAS HDD, 2.5-inch, 12Gb/s, 10,000 rpm, 512n sector 600GB 10K Hot Plug 2.5-inch SAS HDD 1 x 600 GB SAS HDD, 2.5-inch, 12Gb/s, 10,000 rpm, 512n sector 900GB 10K Hot Plug 2.5-inch SAS HDD 1 x 900 GB SAS HDD, 2.5-inch, 12Gb/s, 10,000 rpm, 512n sector 1.2TB 10K Hot Plug 2.5-inch SAS HDD 1 x 1.2TB SAS HDD, 2.5-inch, 12Gb/s, 10,000 rpm, 512n sector 300GB 15K Hot Plug 2.5-inch SAS HDD 1 x 300 GB SAS HDD, 2.5-inch, 12Gb/s, 15,000 rpm, 512n sector 450GB 15K Hot Plug 2.5-inch SAS HDD 1 x 450 GB SAS HDD, 2.5-inch, 12Gb/s, 15,000 rpm, 512n sector 600GB 15K Hot Plug 2.5-inch SAS HDD 1 x 600 GB SAS HDD, 2.5-inch, 12Gb/s, 15,000 rpm, 512n sector 1.8TB 10K Hot Plug 2.5-inch SAS HDD 1x 1.8TB SAS HDD, 2.5-inch, 12Gb/s, 10,000 rpm, 4Kn sector N8150-479 250GB 7.2K Hot Plug 2.5-inch SATA HDD 1 x 250 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm, 512n sector 500GB 7.2K Hot Plug 2.5-inch SATA HDD 1 x 500 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm, 512n sector 1TB 7.2K Hot Plug 2.5-inch SATA HDD 1 x 1 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm, 512n sector 2TB 7.2K Hot Plug 2.5-inch SATA HDD 1 x 2 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm, 512n sector 200GB Hot Plug 2.5-inch SAS SSD 1 x 200 GB SAS SSD, eMLC, 2.5-inch, 12Gb/s, 512n sector 400GB Hot Plug 2.5-inch SAS SSD 1 x 400 GB SAS SSD, eMLC, 2.5-inch, 12Gb/s, 512n sector 200GB Hot Plug 2.5-inch SATA SSD 1 x 200 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, ME 400GB Hot Plug 2.5-inch SATA SSD 1 x 400 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, ME 800GB Hot Plug 2.5-inch SATA SSD 1 x 800 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, ME 200GB Hot Plug 2.5-inch SATA SSD 1 x 200 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, VE 400GB Hot Plug 2.5-inch SATA SSD 1 x 400 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, VE 800GB Hot Plug 2.5-inch SATA SSD 1 x 800 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, VE 1.6TB Hot Plug 2.5-inch SATA SSD 1 x 1.6 TB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, VE N8150-487 N8150-480 N8150-481 N8150-482 N8150-483 N8150-485 N8150-486 N8150-518 N8150-490 N8150-488 N8150-489 N8150-527 N8150-721 N8150-722 N8150-725 N8150-726 N8150-727 N8150-732 N8150-733 N8150-734 N8150-735 NOTE: The 4Kn sector drives are make-to-order products. Please consult your sales representative in regard NEC Corporation Revision 2.1 – May, 2016 24 SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110h to production lead time. When you select 4Kn sector HDD, confirm whether your applications support hard drives with 4Kn sector size. For more information, visit the NEC website at: http://www.nec.com/en/global/prod/express/svropt/hdd/collateral/4KHDD_Precautions_EN.pdf All hard drives within a RAID array should be of the same capacity. Up to two kinds of drives selected from SAS 10K HDDs, SAS 15K HDDs, SATA HDDs, SAS SSDs, SATA SSDs (ME), and SATA SSDs (VE) can be mixed in a system. Mix configurations of 4Kn sector HDDs and 512n sector HDDs are not supported. To configure a large-capacity RAID array, it is recommended to configure in RAID 6 or RAID 60 in order to minimize the risk of becoming multiple hard drives failure during the RAID rebuilding process. The 2.5-inch SAS/SATA SSDs have limited lifetime. Refer to Endurance of SSD for details. 4.3.5 Hot Plug 3.5-inch Drives (1) Category Drive 4slots available SATA HDD (512n) Product Name / Description Part Number 500GB 7.2K Hot Plug 3.5-inch SATA HDD 1 x 500 GB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512n sector 1TB 7.2K Hot Plug 3.5-inch SATA HDD 1 x 1 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512n sector 2TB 7.2K Hot Plug 3.5-inch SATA HDD 1 x 2 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512n sector 3TB 7.2K Hot Plug 3.5-inch SATA HDD 1 x 3 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512n sector 4TB 7.2K Hot Plug 3.5-inch SATA HDD 1 x 4 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512n sector N8150-524 N8150-504 N8150-505 N8150-506 N8150-507 NOTE: Hot plug insertion/removal is not supported with the embedded SATA Non-RAID controller. 4.3.6 Hot Plug 3.5-inch Drives (2) Category Drive 4 slots available SATA HDD (512n) SATA HDD (4Kn) Product Name / Description Part Number 500GB 7.2K Hot Plug 3.5-inch SATA HDD 1 x 500 GB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512n sector 1TB 7.2K Hot Plug 3.5-inch SATA HDD 1 x 1 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512n sector 2TB 7.2K Hot Plug 3.5-inch SATA HDD 1 x 2 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512n sector 3TB 7.2K Hot Plug 3.5-inch SATA HDD 1 x 3 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512n sector 4TB 7.2K Hot Plug 3.5-inch SATA HDD 1 x 4 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512n sector 6TB 7.2K Hot Plug 3.5-inch SATA HDD 1 x 6 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 4Kn sector N8150-524 N8150-504 N8150-505 N8150-506 N8150-507 N8150-503 NOTE: The 4Kn sector drives are make-to-order products. Please consult your sales representative in regard to production lead time. Mix configurations of 4Kn sector HDDs and 512n sector HDDs are not supported. When you select 4Kn sector HDD, confirm whether your applications support hard drives with 4Kn sector size. For more information, visit the NEC website at: http://www.nec.com/en/global/prod/express/svropt/hdd/collateral/4KHDD_Precautions_EN.pdf All drives within a RAID array should be of the same capacity. Embedded SATA RAID Controller does not support RAID 10 configured with 2TB or more HDDs. NEC Corporation Revision 2.1 – May, 2016 25 SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110h 4.3.7 Non-hot plug 3.5-inch Drives (1) Category Drive 4slots available SATA HDD (512n) Product Name / Description Part Number 500GB 7.2K non-Hot Plug 3.5-inch SATA HDD 1 x 500 GB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512n sector 1TB 7.2K non-Hot Plug 3.5-inch SATA HDD 1 x 1 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512n sector 2TB 7.2K non-Hot Plug 3.5-inch SATA HDD 1 x 2 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512n sector 3TB 7.2K non-Hot Plug 3.5-inch SATA HDD 1 x 3 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512n sector 4TB 7.2K non-Hot Plug 3.5-inch SATA HDD 1 x 4 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512n sector N8150-526 N8150-514 N8150-515 N8150-516 N8150-517 NOTE: All drives within a RAID array should be of the same capacity. Embedded SATA RAID Controller does not support RAID 10 configured with 2TB or more HDDs. 4.3.8 Non-hot plug 3.5-inch Drives (2) Category Drive 4slots available SATA HDD (512n) SATA HDD (4Kn) Product Name / Description Part Number 500GB 7.2K non-Hot Plug 3.5-inch SATA HDD 1 x 500 GB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512n sector 1TB 7.2K non-Hot Plug 3.5-inch SATA HDD 1 x 1 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512n sector 2TB 7.2K non-Hot Plug 3.5-inch SATA HDD 1 x 2 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512n sector 3TB 7.2K non-Hot Plug 3.5-inch SATA HDD 1 x 3 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512n sector 4TB 7.2K non-Hot Plug 3.5-inch SATA HDD 1 x 4 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512n sector 6TB 7.2K non-Hot Plug 3.5-inch SATA HDD 1 x 6 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 4Kn sector N8150-526 N8150-514 N8150-515 N8150-516 N8150-517 N8150-513 NOTE: The 4Kn sector drives are make-to-order products. Please consult your sales representative in regard to production lead time. Mix configurations of 4Kn sector HDDs and 512n sector HDDs are not supported. When you select 4Kn sector HDD, confirm whether your applications support hard drives with 4Kn sector size. For more information, visit the NEC website at: http://www.nec.com/en/global/prod/express/svropt/hdd/collateral/4KHDD_Precautions_EN.pdf Embedded SATA RAID Controller does not support RAID 10 configured with 2TB or more HDDs. NEC Corporation Revision 2.1 – May, 2016 26 SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110h 5 Optical Drive Category Product Name / Description Part Number Internal Internal Slim DVD-ROM drive Slim DVD-ROM drive DVD read speed: 8x (DVD-ROM / DVD-R / DVD-RW) CD read speed: 24x (CD-ROM / CD-R/RW) Internal DVD Super Multi Drive Slim DVD Super Multi drive, not including writing software DVD Read speed: 8x (DVD-R / DVD-RW / DVD-R DL / DVD+R / DVD+RW / DVD+R DL / DVD-ROM) DVD-RAM read speed: 5x CD read speed: 24x (CD-ROM / CD-R/RW) External DVD-ROM drive DVD Super Multi drive, Bus powered, 1.5A required, not including writing software DVD Read speed: 8x (DVD-R / DVD-RW / DVD-R DL / DVD+R / DVD+RW / DVD+R DL / DVD-ROM) DVD-RAM read speed: 5x CD read speed: 24x (CD-ROM / CD-R/RW) USB Extension Cable For N8160-97F, USB2.0, 24cm N8151-134 External Cable N8151-135F N8160-97F K410-351(00) NOTE: An optical drive is required for maintenance and OS installation. Up to 1 optical drive can be connected. The USB cable length of N8160-97F is 20 cm. NEC Corporation Revision 2.1 – May, 2016 27 SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110h 6 Internal RDX / LTO Drives 6.1 RDX/LTO Drive Selection Refer to the section in accordance with your type of tape drives: RDX: Refer to 6.2.1 LTO: Refer to 6.2.2 NOTE: Tape devices cannot be directly connected to VMware ESXi servers. For an ESXi environment, it is recommended to connect and configure an additional backup server via network. 6.2 RDX/LTO Configuration 6.2.1 RDX Drive Category Product Name / Description Part Number Controller Internal USB Controller 1 x USB port Internal USB cable 1x Internal USB3.0 to 1x USB 3.0 device Internal RDX (USB) (Standard) Cable Required Drive 1 drive available 6.2.2 K410-276(00) N8151-125 LTO Drive Category Product Name / Description Part Number Controller Required SAS Controller LSI SAS9212-4i4e Host Bus Adapter 6Gbps SAS, Int. 4, Ext. 4, 7-pin SATA / SFF-8088, PCIe 2.0 x8 Internal SAS Cable 1x 7-pin Single SATA to 1x SFF-8482 SAS N8103-142 Internal LTO (SAS) LTO3, Half height, Native capacity 400 GB Internal LTO (SAS) LTO4, Half height, Native capacity 800 GB Internal LTO (SAS) LTO5, Half height, Native capacity 1.5 TB Internal LTO (SAS) LTO6, Half height, Native capacity 2.5 TB N8151-126 Cable Required Drive 1 drive available NEC Corporation Revision 2.1 – May, 2016 K410-217(00) N8151-127 N8151-128 N8151-129 28 SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110h 7 PCI Card Please refer to Supported PCI cards and Installable Slots with regard to the position of PCI slot which can mount PCI card supported. 7.1 Network Interface Controller Category Adapter GbE Product Name / Description Part Number 1000BASE-T Adapter Broadcom ® BCM5718 Gigabit Ethernet Controller PCIe 2.0 x1 Dual Port 1000BASE-T Adapter Broadcom ® BCM5718 Gigabit Ethernet Controller PCIe 2.0 x1 Quad Port 1000BASE-T Adapter Broadcom ® BCM5719 Gigabit Ethernet Controller PCIe 2.0 x4 NOTE: N8104-150 - 10GbE SFP+ Module N8104-152 Network cables with RJ-45 plug covers cannot be used. 10GBASE SFP+ Adapter (SFP+/2ch) Qlogic® NetXtreme II BCM57810 10G SFP+ Dual Port Network Interface Card PCIe 2.0 x8 NOTE: - N8104-151 N8104-149 N8104-129 SFP+ Module is required to connect with an optical cable. Up to two SFP+ Modules can be installed. Up to two adapters can be installed. Dual Port 10GBASE-T Adapter Intel® Ethernet Controller X540 PCIe 2.0(x8) SFP+ Module (10G-SR) 1 x SFP+ Module for N8104-149 N8104-153 N8104-129 NIC Teaming feature – NIC Teaming and bonding features See the table below for supported network interfaces and OS combinations. Windows Server 2008 R2 supports BASP (Broadcom Advanced Server Program) teaming while Windows Server 2012 or later and Linux support teaming with bonding function supported by OS. Network Interface Team OS 1GbE NIC Embedded 1GbE NIC and N8104-150/-151/-152 Up to four teams per one system Up to four ports per one team Windows Server 2008 R2 Windows Server 2012 Windows Server 2012 R2 Red Hat Enterprise Linux 10GbE NIC N8104-149 Up to two teams per one system Up to two ports per one team Windows Server 2008 R2 Windows Server 2012 Windows Server 2012 R2 Red Hat Enterprise Linux 10GbE NIC N8104-153 Up to one teams per one system Up to two ports per one team Windows Server 2012 Windows Server 2012 R2 Red Hat Enterprise Linux NOTE: The network interfaces for a teaming must be the same. When 10GbE and 1GbE LAN teams are mixed, the teams must be up to four per one system. NEC Corporation Revision 2.1 – May, 2016 29 SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110h Using iSCSI See the table below for supported network interfaces and OS combinations. Category Network Interface Operating Systems 1GbE Embedded 1GbE NIC/ N8104-150/-151/-152 Windows Server 2008 R2, Windows Server 2012, Windows Server 2012 R2, Red Hat Enterprise Linux 6, Red Hat Enterprise Linux 7, VMware 10GbE N8104-149 Windows Server 2008 R2, Windows Server 2012, Windows Server 2012 R2, Red Hat Enterprise Linux 6, Red Hat Enterprise Linux 7, VMware N8104-153 Windows Server 2012, Windows Server 2012 R2, Red Hat Enterprise Linux 6, Red Hat Enterprise Linux 7, VMware NOTE: NIC Teaming feature is not supported on iSCSI interfaces. 7.2 SAS Controller Product Name / Description Part Number SAS Controller LSI SAS9212-4i4e Host Bus Adapter 6Gb/s SAS, Int. 4 / Ext. 4, 7-pin SATA / SFF-8088, PCIe 2.0 x8 SAS Controller LSI SAS9300-8e Host Bus Adapter 12Gb/s SAS, Int. 4 / Ext. 4, 7-pin SATA / SFF-8088, PCIe 3.0 x8 N8103-142 7.3 N8103-184 Serial Port Adapter Product Name / Description Part Number Serial Port Adapter Serial port fixed to PCI bracket N8117-01A NOTE: Up to one Serial Port Adapter can be installed. NEC Corporation Revision 2.1 – May, 2016 30 SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110h 8 Other Add-in Components 8.1 Fan Kit Product Name / Description Part Number Non-redundant Fan Kit Non-hot plug cooling fan for T110h Non-redundant Power Supply Fan Non-hot plug cooling fan for T110h NOTE: - This optional fan kit is required to install a RAID controller in a non-redundant power supply model and/or to operate the non-redundant power supply model at temperatures over 40°C. (Standard) 8.2 N8181-132F Trusted Platform Module Kit Product Name / Description Part Number Trusted Platform Module Kit TPM 2.0 module N8115-23 NOTE: The kit is not available in China. The kit is not removable after attachment. "TPM Support" in BIOS setup menu must be activated prior to use of this kit. To use Windows BitLocker drive encryption, be sure to keep the "recovery password" of BitLocker function. The recovery password is required to restore data for hardware replacement during a system error. 8.3 Internal Flash Memory Product Name / Description Part Number VMware ESXi support kit Internal USB flash memory to install VMware ESXi system N8106-011 NOTE: The kit does not include VMware ESXi installation media and license. 8.4 High Temperature Support Option Product Name / Description Part Number High temperature resistant Kit Required for high temperature operation over 40°C (up to 48°C) Supported for Non-hot plug power supply model only N8181-146F NOTE: To apply this option, there are some configuration limitations below. Required System Configuration: - For non-redundant power supply model, N8181-132F Non-redundant Power Supply Fan is required. - Internal RDX or LTO must not be installed. NEC Corporation Revision 2.1 – May, 2016 31 SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110h 8.5 Flash FDD Choose the Flash FDD if you need to prepare an alternative device for a floppy drive. Product Name / Description Part Number Flash FDD USB flash emulating USB floppy disk, Native capacity 1.44 MB N8160-96 NOTE: Up to one derive can be connected 8.6 Input Devices Product Name / Description Part Number Keyboard 1 x 104-keys USB keyboard USB Optical Mouse 1 x USB Mouse, 2-button, Optical with wheel N8170-25 N8170-22 NOTE: Keyboard and mouse are not included in the base models. Please order separately if necessary. NEC Corporation Revision 2.1 – May, 2016 32 SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110h 9 Add-on Components 9.1 Server Management License The server integrates the EXPRESSSCOPE Engine 3 as standard. Refer to Server Management for the standard management features. For more extensive remote KVM and remote media features, choose the following kit. Product Name / Description Part Number Remote KVM and Media License Kit License for one server. Remote KVM and remote media are enabled regardless of OS status. Remote KVM: Displays a graphics console on the web browser of the remote terminal (PC/server). Controls keyboard and mouse via the remote terminals' web browser Remote media: Enables the user to use the CD / DVD / FD / Flash memory of the remote terminals (PC/server) as if accessing the local drives. N8115-04 NOTE: Remote KVM and remote media features are not available for virtual machines. 9.2 Dust Proof Kit The server supports the dust resistant feature. Choose the following kit to install the system in dusty places. Category Product Name / Description Part Number Front Bezel Dust Proof Bezel Including 1 set of dust proof filter Dust Proof Bezel with Sensor Including 1 set of filter replacement sensors, 1 set of dust proof filter Dust proof filter (5 pcs.) For N8146-71 Dust Proof filter Removal capacity of particles : Up to 1 μm-sized Filter replacement Sensor For N8146-71 Dust Proof Bezel N8146-71 Filter Sensor 9.3 N8146-72 N8147-27 N8146-73 Rack Conversion Kit The following rack conversion kit is required to install the server into a 19-inch rack system: Product Name / Description Part Number Rack Conversion Kit Convert to 4U form factor N8143-93 9.4 Medium and Cartridge Category RDX NEC Corporation HDD Product Name Drive supported Part Number RDX Cartridge (500GB) N8151-125 N8153-02 RDX Cartridge (1TB) N8151-125 N8153-03 RDX Cartridge (2TB) N8151-125 N8153-09 RDX Cartridge (3TB) N8151-125 N8153-10 Revision 2.1 – May, 2016 33 SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110h References Boot Mode Setting The server supports Legacy mode and UEFI mode (default) as an OS Boot Mode. See the table below for the Boot Mode and X2APIC setting for each Operating System. As the default settings at the factory, UEFI mode is set as OS Boot mode and X2APIC is enabled. Refer to the User’s Guide and change the settings before installing an Operating System requiring Legacy Mode. Operating System Supported Boot Mode Supported X2APIC Setting Windows Server 2008 R2 (x64) Legacy Disabled Windows Server 2012 UEFI Enabled Windows Server 2012 R2 UEFI Enabled Red Hat Enterprise Linux 6(x86_64) UEFI Enabled Red Hat Enterprise Linux 7 UEFI Enabled VMware ESXi 5.5 Update3 Legacy Disabled VMware ESXi 6 Update1 Legacy Disabled NEC Corporation Revision 2.1 – May, 2016 34 SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110h Server Management The EXPRESSSCOPE Engine 3, integrated into the server, provides superior remote control and system management features listed in the table below. Standard Hardware monitoring 1 Temperature/hard drive /fan/voltage/power consumption/ System LAN/degeneration/ 1 (memory/hard drive ) Hardware configuration information collection Hardware event log collection Alerting HW error, Boot error and OS panic (by SNMP, E-Mail) Remote KVM (via LAN) POST/BIOS setup, ROM utility 2 Panic screen, Boot screen 4 5 2,4,5 2,5 GUI-based screen (OS console) - Remote Screen Video Capture - Remote reset/power on-off/ dump Remote Power Capping BIOS/BMC FW update Remote BIOS setup(partial configuration only) OS shutdown 3 3 Remote media (CD/DVD/FD/USB) - CLP (Command Line Protocol) (DMTF compliant) Remote control via Web browser (multi user login at the same time) Scheduling (without UPS, require NEC ESMPRO Manager) 3 3 BIOS setting by using XML file Maintenance EXPRESSSCOPE® Profile key (Backup/restore BIOS/BMC setup information) Others Set automatic IP address via DNS/DHCP LDAP/Active Directory verification/user control Clock synchronization of main unit and the RTC Access log collection Industry Standard 3 3 BIOS/POST stall, Booting, OS stall, shutdown Remote control (via LAN) 2 3 Boot monitoring CUI-based screen (OS console) 1 With Remote KVM and Media License kit IPMI support 2.0 2.0 The feature is not supported on non-hot plug 3.5-inch drive. The optional serial port is not available for the feature. The feature is not supported on VMware systems. Monitoring boot screens is not supported on VMware systems. In VMware systems, only the direct console user interface is supported. NEC Corporation Revision 2.1 – May, 2016 35 SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110h Endurance of SSD The 2.5-inch SAS/SATA SSDs have limited lifetime, which can only be written a limited number of times before it fails. The warranty period of SSD is the stated period of warranty or until the total bytes of written value (PBW) exceeds the limit value, whichever occurs first. It is recommended to check the total bytes of written value periodically. Refer to the table below for the write endurance (PBW and DWPD), warranty period and monitoring tool. SSD Lifetime Part Number Product Name PBW DWPD Period Monitoring Tool N8150-721 200GB Hot Plug 2.5-inch SAS SSD 3.6PBW 10 Times 3 Years N8150-722 400GB Hot Plug 2.5-inch SAS SSD 7.3PBW 10 Times 3 Years Universal RAID Utility, EXPRESSBUILDER (System Test and Diagnostics) SAS SSD SATA SSD (Middle Endurance) N8150-725 200GB Hot Plug 2.5-inch SATA SSD 3.6PBW 10 Times 3 Years N8150-726 400GB Hot Plug 2.5-inch SATA SSD 7.3PBW 10 Times 3 Years N8150-727 800GB Hot Plug 2.5-inch SATA SSD 14.6PBW 10 Times 3 Years SATA SSD (Low Endurance) N8150-732 200GB Hot Plug 2.5-inch SATA SSD 1.1PBW 3 Times 3 Years N8150-733 400GB Hot Plug 2.5-inch SATA SSD 3.0PBW 3 Times 3 Years N8150-734 800GB Hot Plug 2.5-inch SATA SSD 5.3PBW 3 Times 3 Years N8150-735 1.6TB Hot Plug 2.5-inch SATA SSD 10.7PBW 3 Times 3 Years PBW(Peta-Bytes Write): Total amount of data that can be written into the SSD. 1PB=1,000TB. DWPD(Drive Writes per Day): Rewrite capacity of the SSD per day. Check the lifetime of SSD by monitoring tool regularly. It is recommended to replace the SSD before it reaches its end of life. For repurchase, please contact your sales representative. For detailed operating methods of monitoring tool, refer to the User’s Guide. NEC Corporation Revision 2.1 – May, 2016 36 SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110h OS Support Matrix for PCI Cards and Embedded Controllers ESXi 5.5 ESXi 6.0 RHEL 6 x64 RHEL 7 WS 2008 R2 WS 2012 WS 2012 R2 Part Number Product Name - Embedded SATA non-RAID Controller - Embedded SATA RAID Controller - - Embedded 1GbE NIC N8103-188 RAID Controller (RAID 0/1) N8103-176 RAID Controller (1GB, RAID 0/1) N8103-177 RAID Controller (1GB, RAID 0/1/5/6) N8103-178 RAID Controller (2GB, RAID 0/1/5/6) N8104-153 Dual Port 10GBASE-T Adapter - N8104-149 10GBASE SFP+ Adapter (SFP+/2ch) N8103-184 SAS Controller - N8103-142 SAS Controller N8104-152 Quad Port 1000BASE-T Adapter N8104-151 Dual Port 1000BASE-T Adapter N8104-150 1000BASE-T Adapter - - - - Supported PCI cards and Installable Slots Slots Part Number Product Name #1 #2 #3 #4 N8103-188 RAID Controller (RAID 0/1) - - - (1) N8103-176 RAID Controller (1GB, RAID 0/1) - - - (1) N8103-177 RAID Controller (1GB, RAID 0/1/5/6) - - - (1) N8103-178 RAID Controller (2GB, RAID 0/1/5/6) - - - (1) N8104-153 Dual Port 10GBASE-T Adapter - - (1) (2) N8104-149 10GBASE SFP+ Adapter (SFP+/2ch) - - (1) (2) N8103-184 SAS Controller - - (1) (2) N8103-142 SAS Controller - (3) (1) (2) N8104-152 Quad Port 1000BASE-T Adapter (1) (3) - N8104-151 Dual Port 1000BASE-T Adapter (2) (4) (1) (3) N8104-150 1000BASE-T Adapter (2) (4) (1) (3) N8117-01A Serial Port Adapter (2) (4) (1) (3) (2) NOTE: The number between parentheses shows the population priority (recommendation). For example, install N8103-176 in the slot #4 and N8104-153 in the slot #3 when you have those cards. For VMware ESXi 5.5/6.0, there are some limitations as follows: - When any of N8104-149/-153/ is installed, N8104-152 cannot be installed and the number of installable N8104-150/-151 is limited up to one. NEC Corporation Revision 2.1 – May, 2016 37 SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110h For the configuration limitation for VMware ESXi, refer to the following documents. VMware ESXi5.5 https://www.vmware.com/pdf/vsphere5/r55/vsphere-55-configuration-maximums.pdf VMware ESXi6.0 https://www.vmware.com/pdf/vsphere6/r60/vsphere-60-configuration-maximums.pdf Secure Boot Mode This server supports Secure Boot. It is supported with UEFI Boot mode and protects the security by only allowing software programs with digital signature to run. The supported operating systems, software, and boot devices are below. The default setting of Secure Boot is disabled. Keep the setting disabled to use other operating systems and/or software. Supported OS and Software for Secure Boot Mode Operating System Supported Boot Mode Secure Boot Mode Windows Server 2012 UEFI Windows Server 2012 R2 UEFI Software Related to Boot Supported Boot Mode Secure Boot Mode System Diagnostics Utility UEFI EXPRESSBUILDER UEFI Supported Boot Device for Secure Boot Mode Supported Boot Device Part Number RAID controller (RAID0/1) N8103-188 RAID controller (1GB, RAID0/1) N8103-176 RAID controller (1GB, RAID0/1/5/6) N8103-177 RAID controller (2GB, RAID0/1/5/6) N8103-178 RAID controller (2GB, RAID0/1/5/6) N8103-179 NEC Corporation Revision 2.1 – May, 2016 38 SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110h Copyright Notice and Liability Disclaimer The information contained herein is subject to change without notice. Microsoft and Windows Server are either registered trademarks or trademarks of Microsoft Corporation in the United States and/or other countries Intel , Xeon and Pentium are registered trademarks or trademarks of Intel Corporation or its subsidiaries in the United States and other countries. Linux is a trademark of Linus Torvalds. Red Hat is a registered trademark of Red Hat, Inc. in the U.S. All other products, brands, or trade names used in this document are trademarks or registered trademarks of their respective holders. NEC shall not be liable for technical or editorial errors or omissions contained herein. For hard drive capacity measurements, 1 GB = 1 billion bytes. Actual formatted capacity is less. The USB interface is not guaranteed to work properly for all USB devices. NEC Corporation Revision 2.1 – May, 2016 39 SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110h Revision History Revision Date Description 2.1 May 17, 2016 Others: Added DVD read speed information 2.0 April 26, 2016 New products added: Dust Proof Bezel with Sensor N8146-72 Filter replacement Sensor N8146-73 RDX Cartridge (3TB) N8153-10 Discontinued product deleted: RDX Cartridge (320GB) N8153-01 Others: Added a note for Windows Server 2008 R2 installation Changed the Installable slot information for N8103-184 Added SATA SSDs for the RAID configuration for RAID 0/1 (Embedded SATA RAID) (4.3.2) 1.1 February 2, 2016 Corrected typos and errors. 1.0 January 22, 2016 Initial release NEC Corporation Revision 2.1 – May, 2016 40