Express5800/T110h-S - April 26, 2016

NEC Express5800/T110h-S
System Configuration Guide
Introduction
This document contains product and configuration information that will enable you to configure your system. The
guide will ensure fast and proper configuration of your NEC Express5800 server.
April 26, 2016
Revision 2.0
NEC Corporation
SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110h-S
Contents
TECHNICAL SPECIFICATION ........................................................................................ 3
Key Features .......................................................................................................................................... 3
Specification .......................................................................................................................................... 3
EXTERNAL VIEWS ......................................................................................................... 7
Front View .............................................................................................................................................. 7
Rear Views ............................................................................................................................................. 8
Dimensions (mm) .................................................................................................................................. 9
CONFIGURATION DIAGRAM ....................................................................................... 12
Expansion Slots .................................................................................................................................. 13
SERVER CONFIGURATION ......................................................................................... 14
1
2
3
4
5
6
7
8
9
Base Models ................................................................................................................................. 14
Processor ..................................................................................................................................... 14
Memory ......................................................................................................................................... 14
Maximum Available Memory .......................................................................................................... 15
Internal Hard Disk Drives ............................................................................................................ 16
4.1 RAID Configuration .............................................................................................................. 16
4.2 Required Components for RAID Configuration ................................................................... 18
4.3 Supported Drives ................................................................................................................. 22
Internal Optical Drive ................................................................................................................... 25
Internal RDX Drives ..................................................................................................................... 26
PCI Card ........................................................................................................................................ 26
7.1 Network Interface Controller ................................................................................................ 26
7.2 SAS Controller ..................................................................................................................... 27
7.3 Graphics Accelerator ........................................................................................................... 28
7.4 Serial Port Adapter .............................................................................................................. 28
Other Add-in Components .......................................................................................................... 28
8.1 Trusted Platform Module Kit ................................................................................................ 28
8.2 Internal Flash Memory ......................................................................................................... 28
8.3 High Temperature Support Option ....................................................................................... 29
8.4 Flash FDD............................................................................................................................ 29
8.5 Input Devices ....................................................................................................................... 29
Add-on Components ................................................................................................................... 29
9.1 Server Management License............................................................................................... 29
9.2 Dust Proof Kit ...................................................................................................................... 30
9.3 Tamper Proof Power Button Covers .................................................................................... 30
9.4 Rack Conversion Kit ............................................................................................................ 30
9.5 Medium and Cartridge ......................................................................................................... 30
REFERENCES............................................................................................................... 31
Boot Mode Setting .............................................................................................................................. 31
Server Management ............................................................................................................................ 32
Endurance of SSD ............................................................................................................................... 33
OS Support Matrix for PCI Cards and Embedded Controllers ....................................................... 34
Supported PCI cards and Installable Slots....................................................................................... 34
Copyright Notice and Liability Disclaimer ........................................................................................ 36
REVISION HISTORY ..................................................................................................... 37
NEC Corporation
Revision 2.0 – April, 2016
2
SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110h-S
Technical Specification
Key Features





Ultra compact form of 98 mm in width, 13 liters in volume
High performance with the latest Intel® Xeon® processor E3-1200 v5 processor family
Up to 64 GB of high speed DDR4 memory
Agent-less management with improved EXPRESSCOPE Engine 3
Wide range of operating ambient temperature from 5 to 48°C (41 to 118°F)
Specification
(1 / 2)
Model
T110h-S
Part Number
Processor
N8100-2327F, N8100-2328F
Type
Intel® Pentium®
processor G4400
Intel® Xeon®
processor E3-1220
v5
Intel® Xeon®
processor E3-1230
v5
Clock speed
3.30 GHz
3.00 GHz
3.40 GHz
Number of Processors
1
Cache
3 MB
8MB
Cores and Threads
2C / 2T
4C / 4T
Chipset
Memory
Internal Storage
Intel® C236 Chipset
Type
DDR4-2133 ECC Unbuffered DIMM
Standard Capacity
0 GB
Maximum Capacity
64 GB (4 x 16 GB)
Standard Capacity
0 GB
Maximum Capacity
16 TB (2 x 6 TB + 2x 2TB)
Disk Controller
SATA : 6 Gb/s (Integrated)
SATA/SAS : 6/12 Gb/s (Optional)
RAID
SATA : RAID 0/1/10 (Standard )
SATA/SAS : RAID 0/1/5/6/10/50/60 (Optional)
Hot Plug
Supported with hot plug drive bay
Optical Disk Drive
Optional
3.5-inch Media Bays
2
Disk Drive Bays
2 or 4 or 6
1
Expansion Slots
Video
4C / 8T
Total: 4 slots available
1 PCIe 3.0 x16 (x16 connector)
1 PCIe 3.0 x4 (x8 connector)
1 PCIe 3.0 x2 (x8 connector)
1 PCIe 3.0 x1 (x8 connector)
Controller (VRAM)
Integrated in Server Management Controller (32MB)
Resolution / Color
1600 x 1200 / 16.7M
2
Interfaces
1 VGA (15-pin mini D-sub,1 rear)
1 to 2 Serial (9-pin mini D-sub, RS232-C, 1 to 2 rear)
6 USB 3.0 (2 front, 4 rear) (plus 1 internal USB 3.0)
2 1000BASE-T LAN connector (RJ-45, 2 rear)
1 1000BASE-T LAN connector for Management (RJ-45, 1 rear)
Server Management
EXPRESSSCOPE Engine 3
NEC Corporation
Revision 2.0 – April, 2016
3
SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110h-S
1
2
3
4
5
Model
T110h-S
System Fan
Standard
Power Supply
1 x 250 Watt 80 PLUS® Platinum certified non-hot plug PSU
2 x 460 Watt 80 PLUS® Platinum certified Hot plug PSU
100-240 VAC ± 10% 50 / 60 Hz ± 3 Hz
Power
(Max. Config, Idling)
Consumption
Power
(Max. Config,
Consumption
Operating)
Acoustic Noise
Minimum Config.
(Sound Pressure
Maximum Config.
3
Level)
Dimensions (W x D x H )
94 VA / 94 Watt
96 VA / 96 Watt
97 VA / 96 Watt
165 VA / 164 Watt
204 VA / 203 Watt
233 VA / 232 Watt
Weight (Minimum / Maximum)
8 kg / 11.5 kg, 17.64 lbs. / 25.35 lbs.
Temperature, Relative Humidity
(non-condensing)
Operating: 5° to 40 ° C / 41° to 104 ° F or 5 to 48°C / 41 to 118°F
(Optional), 20 to 80%
Non-Operating: -10° to 55° C / 14° to 131° F, 20 to 80%
Regulatory and Safety
FCC, c-UL, CE, CB, RoHS, WEEE, BSMI, CCC
Operating Systems and Virtualization
Software
Microsoft® Windows Server® 2008 R2 Standard
Microsoft® Windows Server® 2008 R2 Enterprise
Microsoft® Windows Server® 2012 Standard
Microsoft® Windows Server® 2012 Datacenter
Microsoft® Windows Server® 2012 R2 Standard
Microsoft® Windows Server® 2012 R2 Datacenter
4
Red Hat Enterprise Linux 6.7 or later (x86_64)
4
Red Hat Enterprise Linux 7.2 or later
5
VMware ESXi 5.5 Update 3
5
VMware ESXi 6.0 Update 1
26.1 dB
35.8 dB
98.0 x 386.5 x 341.0 mm / 3.9 x 15.2 x 13.4 in
Embedded SATA RAID controller is supported only on limited operating systems.
Maximum resolution available via EXPRESSSCOPE Engine 3 remote console is 1280 x 1024 / 65K colors.
Noise emission was measured in accordance with ISO 7779, at 25°C. The actual value may vary by the operating
environment.
For Linux support, contact your sales representative or go to the NEC website at:
http://www.nec.com/global/prod/express/linux/index.html
Support on Xeon and Core processor systems only.
(2 / 2)
Model
T110h-S
Part Number
Processor
N8100-2327F, N8100-2328F
Type
Intel® Xeon®
processor
E3-1240L v5
Intel® Xeon®
processor
E3-1260L v5
Intel® Xeon®
processor
E3-1270 v5
Clock speed
2.10 GHz
2.90 GHz
3.60 GHz
Number of Processors
1
Cache
8 MB
Cores and Threads
4C / 8T
Chipset
Memory
NEC Corporation
Intel® C236 Chipset
Type
DDR4-2133 ECC Unbuffered DIMM
Standard Capacity
0 GB
Maximum Capacity
64 GB (4 x 16 GB)
Revision 2.0 – April, 2016
4
SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110h-S
Model
Internal Storage
T110h-S
Standard Capacity
0 GB
Maximum Capacity
16 TB (2 x 6 TB + 2x 2TB)
Disk Controller
SATA : 6 Gb/s (Integrated)
SATA/SAS : 6/12 Gb/s (Optional)
RAID
SATA : RAID 0/1/10 (Standard )
SATA/SAS : RAID 0/1/5/6/10/50/60 (Optional)
Hot Plug
Supported with hot plug drive bay
Optical Disk Drive
Optional
3.5-inch Media Bays
2
Disk Drive Bays
2 or 4 or 6
1
Expansion Slots
Video
1
2
3
Total: 4 slots available
1 PCIe 3.0 x16 (x16 connector)
1 PCIe 3.0 x4 (x8 connector)
1 PCIe 3.0 x2 (x8 connector)
1 PCIe 3.0 x1 (x8 connector)
Controller (VRAM)
Integrated in Server Management Controller (32MB)
Resolution / Color
1600 x 1200 / 16.7M
2
Interfaces
1 VGA (15-pin mini D-sub,1 rear)
1 to 2 Serial (9-pin mini D-sub, RS232-C, 1 to 2 rear)
6 USB 3.0 (2 front, 4 rear) (plus 1 internal USB 3.0)
2 1000BASE-T LAN connector (RJ-45, 2 rear)
1 1000BASE-T LAN connector for Management (RJ-45, 1 rear)
Server Management
EXPRESSSCOPE Engine 3
System Fan
Standard
Power Supply
1 x 250 Watt 80 PLUS® Platinum certified non-hot plug PSU
2 x 460 Watt 80 PLUS® Platinum certified Hot plug PSU
100-240 VAC ± 10% 50 / 60 Hz ± 3 Hz
Power
(Max. Config, Idling)
94 VA / 94 Watt
Consumption
(Max. Config,
Operating)
Minimum Config.
153 VA / 152 Watt
96 VA / 95 Watt
185 VA / 184 Watt
232 VA / 230 Watt
Acoustic Noise
(Sound Pressure
Maximum Config.
3
Level)
Dimensions (W x D x H )
26.1 dB
Weight (Minimum / Maximum)
8 kg / 11.5 kg, 17.64 lbs. / 25.35 lbs.
Temperature, Relative Humidity
(non-condensing)
Operating: 5° to 40 ° C / 41° to 104 ° F or 5 to 48°C / 41 to 118°F
(Optional), 20 to 80%
Non-Operating: -10° to 55° C / 14° to 131° F, 20 to 80%
Regulatory and Safety
FCC, c-UL, CE, CB, RoHS, WEEE, BSMI, CCC
Operating Systems and Virtualization
Software
Microsoft® Windows Server® 2008 R2 Standard
Microsoft® Windows Server® 2008 R2 Enterprise
Microsoft® Windows Server® 2012 Standard
Microsoft® Windows Server® 2012 Datacenter
Microsoft® Windows Server® 2012 R2 Standard
Microsoft® Windows Server® 2012 R2 Datacenter
4
Red Hat Enterprise Linux 6.7 or later (x86_64)
4
Red Hat Enterprise Linux 7.2 or later
5
VMware ESXi 5.5 Update 3
5
VMware ESXi 6.0 Update 1
35.8 dB
98.0 x 386.5 x 341.0 mm / 3.9 x 15.2 x 13.4 in
Embedded SATA RAID controller is supported only on limited operating systems.
Maximum resolution available via EXPRESSSCOPE Engine 3 remote console is 1280 x 1024 / 65K colors.
Noise emission was measured in accordance with ISO 7779, at 25°C. The actual value may vary by the operating
NEC Corporation
Revision 2.0 – April, 2016
5
SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110h-S
4
5
environment.
For Linux support, contact your sales representative or go to the NEC website at:
http://www.nec.com/global/prod/express/linux/index.html
Support on Xeon and Core processor systems only.
NEC Corporation
Revision 2.0 – April, 2016
6
SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110h-S
External Views
Front View
A
B
C
D
F
H
E
G
I
K
J
L
M
N
Legend
A.
Power Button
H.
Global LED 1
B.
Dump (NMI) Button
I.
Global LED 2
C.
BMC Reset Button
J.
USB 3.0 Connectors
Optical Disk Drive
D.
Power LED
K.
E.
Power Capping LED
L.
Cover Key (2.5 inch Drive
Configuration)
F.
STATUS LED 1
M.
Drive Bay Cover
STATUS LED 2
N.
Stabilizer
G.
NEC Corporation
Revision 2.0 – April, 2016
7
SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110h-S
Rear Views
Non-redundant power supply model
Redundant power supply model
A
G
B
H
C
E
D
F
Legend
A.
B.
C.
D.
Serial Port Connector
VGA Connector
USB Connectors
Management LAN Connector
NEC Corporation
E.
F.
G.
H.
Data LAN Connectors
PCI Slots
AC Inlet
Power Supply Unit
Revision 2.0 – April, 2016
8
SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110h-S
Dimensions (mm)
Standard Bezel
Tower Orientation
98.0
347.1
386.5
395.4
200.0
Desktop Orientation
104.2
395.4
386.5
NEC Corporation
Revision 2.0 – April, 2016
347.1
9
SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110h-S
Dust Proof Bezel
Tower Orientation (Non-redundant power supply)
98.0
347.1
423.7
200.0
415.7
Desktop Orientation (Non-redundant power supply)
104.2
423.7
415.7
NEC Corporation
Revision 2.0 – April, 2016
347.1
10
SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110h-S
Tower Orientation (Redundant power supply)
98.0
347.1
415.7
200.0
447.5
Desktop Orientation (Redundant power supply)
104.2
447.5
415.7
NEC Corporation
Revision 2.0 – April, 2016
347.1
11
SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110h-S
Configuration Diagram
Non-redundant Power Supply Model
Legend:
Standard Components
Mandatory Components
Redundant Power Supply Model
Legend:
NEC Corporation
Standard Components
Mandatory Components
Revision 2.0 – April, 2016
12
SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110h-S
Expansion Slots
Slot #1
Slot #2
Slot #3
Slot #4
Legend
#1
PCIe 3.0 x2, x8 connector, Low Profile, up to 168mm length
#2
PCIe 3.0 x1, x8 connector, Low Profile, up to 168mm length
#3
PCIe 3.0 x16, x16 connector, Low Profile, up to 168mm length
#4
PCIe 3.0 x4, x8 connector, Low Profile, up to 168mm length
NEC Corporation
Revision 2.0 – April, 2016
13
SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110h-S
Server Configuration
1 Base Models
Product Name / Description
Part Number
Express5800/T110h-S
no Processor, no RAM, no Drive Cage, no HDD, no Optical Drive
Including:
250 Watt non-hot plug power supply
Express5800/T110h-S
no Processor, no RAM, no Drive Cage, no HDD, no Optical Drive
Including:
2x 460 Watt hot plug power supply
N8100-2327F
N8100-2328F
NOTE:

The base model must be ordered with a processor kit, memory, a drive cage, and an optical drive.

For Windows Server 2008 R2 installation, EXPRESSBUILDER DVD is required.
2 Processor
Available sockets: 1
Category
Product Name / Description
Part Number
Processors
Required
Pentium G4400 Processor Kit
Intel® Pentium ® Processor G4400 (3.3 GHz, 2C/2T, 3 MB)
Xeon E3-1220v5 Processor Kit
Intel® Xeon ® Processor E3-1220 v5 (3.0 GHz, 4C/4T, 8 MB)
Xeon E3-1230 v5 Processor Kit
Intel® Xeon ® Processor E3-1230 v5 (3.4 GHz, 4C/8T, 8 MB)
Xeon E3-1240L v5 Processor Kit
Intel® Xeon ® Processor E3-1240L v5 (2.1 GHz, 4C/8T, 8 MB)
Xeon E3-1260L v5 Processor Kit
Intel® Xeon ® Processor E3-1260L v5 (2.9 GHz, 4C/8T, 8 MB)
Xeon E3-1270 v5 Processor Kit
Intel® Xeon ® Processor E3-1270 v5 (3.6 GHz, 4C/8T, 8 MB)
N8101-939F
N8101-941F
N8101-942F
N8101-943F
N8101-944F
N8101-945F
NOTE:

One processor kit from above must be installed.

VMware ESXi is supported only on Xeon processor systems.
3 Memory
Available slots: 4
Product Name / Description
Part Number
4GB DDR4-2133 UNB Memory Kit
1 x 4GB Unbuffered ECC DIMM, DDR4-2133
8GB DDR4-2133 UNB Memory Kit
1 x 8GB Unbuffered ECC DIMM, DDR4-2133
16GB DDR4-2133 UNB Memory Kit
1 x 16GB Unbuffered ECC DIMM, DDR4-2133
N8102-656F
N8102-657F
N8102-658F
NOTE:



Minimum one memory kit must be installed.
It is recommended to install memory kits in pairs of two identical DIMMs for dual-channel symmetric
memory configurations to increase memory transfer speed.
The memory requirement to run VMware ESXi™ are below:
NEC Corporation
Revision 2.0 – April, 2016
14
SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110h-S
- VMware ESXi 5.5 : at least 5 GB
- VMware ESXi 6.0 : at least 5 GB
Maximum Available Memory
See the table below for the maximum memory size that you can actually use on your system.
Maximum Memory Size
Supported by Operating
Systems
Maximum Available Memory
32 GB
32 GB
2 TB
64 GB
Microsoft Windows Server 2012 Standard
Microsoft Windows Server 2012 Datacenter 1
Microsoft Windows Server 2012 R2 Standard 1
Microsoft Windows Server 2012 R2 Datacenter 1
4 TB
64 GB
Red Hat Enterprise Linux 6 (x86_64)
Red Hat Enterprise Linux 7
6 TB
64 GB
VMware ESXi 5.5 2
4 TB
64 GB
3
6 TB
64 GB
Operating Systems
Microsoft Windows Server 2008 R2 Standard 1
Microsoft Windows Server 2008 R2 Enterprise
1
VMware ESXi 6.0
1
2
3
1
The maximum available memory size of Hyper-V systems is below:
- Windows Server 2008 R2 Standard : 32 GB
- Windows Server 2008 R2 Enterprise : 1TB
- Windows Server 2012 and Windows Server 2012 R2 : 4 TB
Up to 1 TB of main memory is available to each virtual machine.
Up to 4 TB of main memory is available to each virtual machine.
NEC Corporation
Revision 2.0 – April, 2016
15
SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110h-S
4 Internal Hard Disk Drives
4.1
RAID Configuration
Refer to the section in accordance with your disk form factor and RAID configuration
Slot 5
2.5-inch Drive
Slot 4
4.1.1
Slot
Slot
Slot
Slot
Operating System
3
2
1
0
Supported RAID configuration
RAID and Cache
Windows Server 2008 R2
VMware ESXi 5.5
VMware ESXi 6
KVM in Red Hat Enterprise
Linux 6 (x86_64)
Windows Server 2012
Windows Server 2012 R2
Red Hat Enterprise Linux 6
(x86_64) without KVM
Red Hat Enterprise Linux 7
Supported
HDD/SSD
Section
Non-RAID (Embedded SATA)
4.2.1
4.3.1
RAID 0/1/10
No Cache
4.2.3
4.3.3
RAID 0/1/10
1GB Cache
4.2.4
RAID 5/6/50/60
1GB Cache
4.2.5
RAID 5/6/50/60
2GB Cache
4.2.6
Non-RAID (Embedded SATA)
4.2.1
4.3.1
RAID 0/1 (Embedded SATA RAID)
4.2.2
4.3.2
RAID 0/1/10
No Cache
4.2.3
4.3.4
RAID 0/1/10
1GB Cache
4.2.4
RAID 5/6/50/60
1GB Cache
4.2.5
RAID 5/6/50/60
2GB Cache
4.2.6
Non-RAID (Embedded SATA)
4.2.1
4.3.1
RAID 0/1/10
No Cache
4.2.3
4.3.4
RAID 0/1/10
1GB Cache
4.2.4
RAID 5/6/50/60
1GB Cache
4.2.5
RAID 5/6/50/60
2GB Cache
4.2.6
NOTE:




Up to four drives can be installed when you choose the Embedded SATA Non-RAID controller.
All drives within a RAID array should be of the same capacity and rotation speed.
Up to two kinds of drives selected from SAS 10K HDDs, SAS 15K HDDs, SATA HDDs, and SSDs can
be mixed in a system. However, SAS HDDs and SATA HDDs cannot be mixed in the same cage, and
HDDs in the same cage must have the same rotational speed.
Mix configurations of 4Kn sector HDDs and 512n sector HDDs are not supported.
NEC Corporation
Revision 2.0 – April, 2016
16
SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110h-S
Internal RDX drive cannot be installed in the redundant power supply model with optional 2.5-inch
drive cage.
3.5-inch Drive
Operating System
Slot 1
Slot 0
Slot 4
4.1.2
Slot 5

Supported RAID configuration
RAID and Cache
Supported
HDD/SSD
Section
Windows Server 2008 R2
VMware ESXi 5.5
VMware ESXi 6
KVM in Red Hat Enterprise
Linux 6 (x86_64)
Non-RAID (Embedded SATA)
4.2.7
RAID 0/1/10
No Cache
4.2.9
RAID 0/1/10
1GB Cache
4.2.10
3.5-inch: 4.3.5
2.5-inch: 4.3.2
Windows Server 2012
Windows Server 2012 R2
Non-RAID (Embedded SATA)
4.2.7
4.3.6
RAID 0/1 (Embedded SATA RAID)
4.2.8
RAID 0/1/10
No Cache
4.2.9
RAID 0/1/10
1GB Cache
4.2.10
3.5-inch: 4.3.6
2.5-inch: 4.3.4
Non-RAID (Embedded SATA)
4.2.7
4.3.6
RAID 0/1/10
No Cache
4.2.9
RAID 0/1/10
1GB Cache
4.2.10
Red Hat Enterprise Linux 6
(x86_64) without KVM
Red Hat Enterprise Linux 7
4.3.5
3.5-inch: 4.3.6
2.5-inch: 4.3.4
NOTE:






All hard drives within a RAID array should be of the same capacity and rotation speed.
2.5-inch drives installed in the optional cage must be identical.
Install an operating system in the 3.5-inch drives with this configuration.
2.5-inch drives cannot be set as hot-spare for the RAID group of 3.5-inch drives.
Internal RDX drive cannot be installed in the redundant power supply model with optional 2.5-inch
drive cage.
Hot plug insertion/removal of any drive is not supported when both 3.5-inch and 2.5-inch drives are
installed.
NEC Corporation
Revision 2.0 – April, 2016
17
SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110h-S
4.2
Required Components for RAID Configuration
4.2.1
Embedded SATA non-RAID Controller for 2.5-inch Drives
Category
Product Name / Description
Part Number
Storage Controller
Embedded SATA Controller
4x 6Gb/s SATA
Internal SATA Cable
Mini-SAS to mini-SAS
2.5-inch Drive Cage
4 x 2.5-inch hot plug drive bays
(Standard)
Cable
Drive Cage
Required
(Included in the
Drive Cage)
N8154-82F
NOTE

Hot plug insertion/removal is not supported with the embedded SATA non-RAID controller.
4.2.2
Embedded SATA RAID Controller for 2.5-inch Drives
Category
Product Name / Description
Part Number
Storage Controller
Embedded SATA Controller
4x 6Gb/s SATA, RAID0/1/10 capable
Internal SATA Cable
Mini-SAS to mini-SAS
2.5-inch Drive Cage
4 x 2.5-inch hot plug drive bays
(Standard)
Cable
Drive Cage
Required
(Included in the
Drive Cage)
N8154-82F
NOTE

All hard drives within a RAID array should be of the same capacity and rotation speed.
4.2.3
RAID 0/1 Controller without Cache for 2.5-inch Drives
Category
Product Name / Description
Part Number
Storage Controller
Required
RAID Controller (RAID 0/1)
Avago(LSI) MegaRAID SAS 9341-8i
RAID0/1/10, no memory cache, Int. 8, PCIe 3.0(x8), SAS
12Gb/s, SATA 6Gb/s
Internal SATA Cable
mini-SAS to mini-SAS, miniSAS – 2x Single SATA
2.5-inch Drive Cage
4 x 2.5-inch hot plug drive bays
2.5-Inch Hot Plug Drive Cage Kit
2x 2.5-inch hot plug drive bays
Including 1x mini-SAS to 2x Single SATA cable
N8103-188
Cable
Drive Cage
Required
Optional Drive Cage
(For more than 4
drives)
(Included in the
Drive Cage)
N8154-82F
N8154-83F
NOTE:

All drives within a RAID array should be of the same type, capacity and rotation speed.
NEC Corporation
Revision 2.0 – April, 2016
18
SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110h-S
4.2.4
RAID 0/1 Controller with 1 GB Cache for 2.5-inch Drives
Category
Product Name / Description
Part Number
Storage Controller
Required
RAID Controller (1GB, RAID 0/1)
LSI MegaRAID SAS 9362-8i
RAID0/1/10, 1GB, Int. 8, PCIe 3.0(x8), SAS 12Gb/s, SATA 6Gb/s
Flash Backup Unit
for LSI MegaRAID SAS 9362-8i
500mm Cable for Flash Backup Unit included
Internal SATA Cable
mini-SAS to mini-SAS, miniSAS – 2x Single SATA
2.5-inch Drive Cage
4 x 2.5-inch hot plug drive bays
2.5-Inch Hot Plug Drive Cage Kit
2x 2.5-inch hot plug drive bays
Including 1x mini-SAS to 2x Single SATA cable
N8103-176
Flash Backup
Recommended
Cable
Drive Cage
Required
Optional Drive Cage
(For more than 4
drives)
N8103-180
(Included in the
Drive Cage)
N8154-82F
N8154-83F
NOTE:

All drives within a RAID array should be of the same type, capacity and rotation speed.
4.2.5
RAID 5/6 Controller with 1 GB Cache for 2.5-inch Drives
Category
Product Name / Description
Part Number
Storage Controller
Required
RAID Controller (1GB, RAID 0/1/5/6)
LSI MegaRAID SAS 9362-8i
RAID0/1/5/6/10/50/60, 1GB, Int. 8, PCIe 3.0(x8), SAS 12Gb/s,
SATA 6Gb/s
Flash Backup Unit
for LSI MegaRAID SAS 9362-8i
500mm Cable for Flash Backup Unit included
Internal SATA Cable
mini-SAS to mini-SAS, miniSAS – 2x Single SATA
2.5-inch Drive Cage
4 x 2.5-inch hot plug drive bays
2.5-Inch Hot Plug Drive Cage Kit
2x 2.5-inch hot plug drive bays
Including 1x mini-SAS to 2x Single SATA cable
N8103-177
Flash Backup
Recommended
Cable
Drive Cage
Required
Optional Drive Cage
(For more than 4
drives)
N8103-180
(Included in the
Drive Cage)
N8154-82F
N8154-83F
NOTE:

All drives within a RAID array should be of the same type, capacity and rotation speed.
NEC Corporation
Revision 2.0 – April, 2016
19
SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110h-S
4.2.6
RAID 5/6 Controller with 2 GB Cache for 2.5-inch Drives
Category
Product Name / Description
Part Number
Storage Controller
Required
RAID Controller (2GB, RAID 0/1/5/6)
LSI MegaRAID SAS 9362-8i
RAID0/1/5/6/10/50/60, 2 GB, Int. 8, PCIe 3.0(x8), SAS 12Gb/s,
SATA 6Gb/s
Flash Backup Unit
for LSI MegaRAID SAS 9362-8i
500mm Cable for Flash Backup Unit included
Internal SATA Cable
mini-SAS to mini-SAS, miniSAS – 2x Single SATA
2.5-inch Drive Cage
4 x 2.5-inch hot plug drive bays
2.5-Inch Hot Plug Drive Cage Kit
2x 2.5-inch hot plug drive bays
Including 1x mini-SAS to 2x Single SATA cable
N8103-178
Flash Backup
Recommended
Cable
Drive Cage
Required
Optional Drive Cage
(For more than 4
drives)
N8103-180
(Included in the
Drive Cage)
N8154-82F
N8154-83F
NOTE:

All drives within a RAID array should be of the same type, capacity and rotation speed.
4.2.7
Embedded SATA non-RAID Controller for 3.5-inch Drives
Category
Product Name / Description
Part Number
Storage Controller
Embedded SATA Controller
4x 6Gb/s SATA
Internal SAS/SATA Cable
miniSAS to 2x Single SATA
3.5-inch Drive Cage
2 x 3.5-inch non hot plug (fixed) drive bays
(Standard)
Cable
Drive Cage
Required
4.2.8
(Included in the
Drive Cage)
N8154-84F
Embedded SATA RAID Controller for 3.5-inch Drives
Category
Product Name / Description
Part Number
Storage Controller
Embedded SATA Controller
4x 6Gb/s SATA
Internal SAS/SATA Cable
miniSAS to 2x Single SATA
3.5-inch Drive Cage
2 x 3.5-inch non hot plug (fixed) drive bays
(Standard)
Cable
Drive Cage
Required
(Included in the
Drive Cage)
N8154-84F
NOTE:

All hard drives within a RAID array should be of the same capacity.
NEC Corporation
Revision 2.0 – April, 2016
20
SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110h-S
4.2.9
RAID 0/1 Controller without Cache for 3.5-inch Drives
Category
Product Name / Description
Part Number
Storage Controller
Required
RAID Controller (RAID 0/1)
Avago(LSI) MegaRAID SAS 9341-8i
RAID0/1/10, no memory cache, Int. 8, PCIe 3.0(x8), SAS
12Gb/s, SATA 6Gb/s
RAID LED Cable
N8103-188
Internal SAS/SATA Cable
miniSAS to 2x Single SATA
3.5-inch Drive Cage
2 x 3.5-inch non hot plug (fixed) drive bays
(Included in the
Drive Cage)
Cable
Required
Cable
Drive Cage
Required
K410-293(00)
N8154-84F
NOTE:

All hard drives within a RAID array should be of the same capacity.
4.2.10 RAID 0/1 Controller with 1 GB Cache for 3.5-inch and 2.5-inch Drives
Category
Product Name / Description
Part Number
Storage Controller
Required
RAID Controller (1GB, RAID 0/1)
LSI MegaRAID SAS 9362-8i
RAID0/1/10, 1GB, Int. 8, PCIe 3.0(x8), SAS 12Gb/s, SATA 6Gb/s
Flash Backup Unit
for LSI MegaRAID SAS 9362-8i
500mm Cable for Flash Backup Unit included
RAID LED Cable
N8103-176
Internal SATA Cable
mini-SAS to 2x Single SATA, for 3.5-inch drive cage
Internal SAS/SATA Cable
mini-SAS to 2x Single SATA, for 2.5-inch drive cage
3.5-inch Drive Cage
2 x 3.5-inch non hot plug (fixed) drive bays
2.5-Inch Hot Plug Drive Cage Kit
2x 2.5-inch hot plug drive bays
Including 1x mini-SAS to 2x Single SATA cable
(Standard)
Flash Backup
Recommended
Cable
Required
Cable
Drive Cage
Required
Optional Drive Cage
(For more than 2
drives)
N8103-180
K410-293(00)
(Included in the
Drive Cage)
N8154-84F
N8154-83F
NOTE:

All hard drives within a RAID array should be of the same capacity.

2.5-inch drives installed in the optional cage must be identical.

Hot plug insertion/removal of any drive is not supported when both 3.5-inch and 2.5-inch drives are
installed.
NEC Corporation
Revision 2.0 – April, 2016
21
SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110h-S
4.3
Supported Drives
4.3.1
2.5-inch Drives (1)
Category
Drive
For 2.5-inch
drive cage:
4 slots
available
SATA
HDD
For optional
drive cage:
2 slots
available
4.3.2
Drive
For 2.5-inch
drive cage:
4 slots
available
For optional
drive cage:
2 slots
available
SATA
HDD
(512n)
SATA
SSD
(ME)
SATA
SSD
(VE)
250GB 7.2K Hot Plug 2.5-inch SATA HDD
1 x 250 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm, 512n sector
500GB 7.2K Hot Plug 2.5-inch SATA HDD
1 x 500 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm, 512n sector
1TB 7.2K Hot Plug 2.5-inch SATA HDD
1 x 1 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm, 512n sector
2TB 7.2K Hot Plug 2.5-inch SATA HDD
1 x 2 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm, 512n sector
N8150-487
N8150-488
N8150-489
N8150-527
Product Name / Description
Part Number
250GB 7.2K Hot Plug 2.5-inch SATA HDD
1 x 250 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm, 512n sector
500GB 7.2K Hot Plug 2.5-inch SATA HDD
1 x 500 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm, 512n sector
1TB 7.2K Hot Plug 2.5-inch SATA HDD
1 x 1 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm, 512n sector
2TB 7.2K Hot Plug 2.5-inch SATA HDD
1 x 2 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm, 512n sector
200GB Hot Plug 2.5-inch SATA SSD
1 x 200 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, ME
400GB Hot Plug 2.5-inch SATA SSD
1 x 400 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, ME
800GB Hot Plug 2.5-inch SATA SSD
1 x 800 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, ME
200GB Hot Plug 2.5-inch SATA SSD
1 x 200 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, VE
400GB Hot Plug 2.5-inch SATA SSD
1 x 400 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, VE
800GB Hot Plug 2.5-inch SATA SSD
1 x 800 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, VE
1.6TB Hot Plug 2.5-inch SATA SSD
1 x 1.6 TB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, VE
N8150-487
N8150-488
N8150-489
N8150-527
N8150-725
N8150-726
N8150-727
N8150-732
N8150-733
N8150-734
N8150-735
2.5-inch Drives (3)
Category
Drive
For 2.5-inch
drive cage:
4 slots
available
For optional
drive cage:
2 slots
available
NEC Corporation
Part Number
2.5-inch Drives (2)
Category
4.3.3
Product Name / Description
SAS
HDD
(512n)
Product Name / Description
Part Number
300GB 10K Hot Plug 2.5-inch SAS HDD
1 x 300 GB SAS HDD, 2.5-inch, 12Gb/s, 10,000 rpm, 512n sector
450GB 10K Hot Plug 2.5-inch SAS HDD
1 x 450 GB SAS HDD, 2.5-inch, 12Gb/s, 10,000 rpm, 512n sector
600GB 10K Hot Plug 2.5-inch SAS HDD
1 x 600 GB SAS HDD, 2.5-inch, 12Gb/s, 10,000 rpm, 512n sector
900GB 10K Hot Plug 2.5-inch SAS HDD
1 x 900 GB SAS HDD, 2.5-inch, 12Gb/s, 10,000 rpm, 512n sector
1.2TB 10K Hot Plug 2.5-inch SAS HDD
1 x 1.2TB SAS HDD, 2.5-inch, 12Gb/s, 10,000 rpm, 512n sector
300GB 15K Hot Plug 2.5-inch SAS HDD
1 x 300 GB SAS HDD, 2.5-inch, 12Gb/s, 15,000 rpm, 512n sector
N8150-479
Revision 2.0 – April, 2016
N8150-480
N8150-481
N8150-482
N8150-483
N8150-485
22
SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110h-S
SATA
HDD
(512n)
SAS
SSD
(eMLC)
SATA
SSD
(ME)
SATA
SSD
(VE)
450GB 15K Hot Plug 2.5-inch SAS HDD
1 x 450 GB SAS HDD, 2.5-inch, 12Gb/s, 15,000 rpm, 512n sector
600GB 15K Hot Plug 2.5-inch SAS HDD
1 x 600 GB SAS HDD, 2.5-inch, 12Gb/s, 15,000 rpm, 512n sector
250GB 7.2K Hot Plug 2.5-inch SATA HDD
1 x 250 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm, 512n sector
500GB 7.2K Hot Plug 2.5-inch SATA HDD
1 x 500 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm, 512n sector
1TB 7.2K Hot Plug 2.5-inch SATA HDD
1 x 1 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm, 512n sector
2TB 7.2K Hot Plug 2.5-inch SATA HDD
1 x 2 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm, 512n sector
200GB Hot Plug 2.5-inch SAS SSD
1 x 200 GB SAS SSD, eMLC, 2.5-inch, 12Gb/s, 512n sector
400GB Hot Plug 2.5-inch SAS SSD
1 x 400 GB SAS SSD, eMLC, 2.5-inch, 12Gb/s, 512n sector
200GB Hot Plug 2.5-inch SATA SSD
1 x 200 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, ME
400GB Hot Plug 2.5-inch SATA SSD
1 x 400 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, ME
800GB Hot Plug 2.5-inch SATA SSD
1 x 800 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, ME
200GB Hot Plug 2.5-inch SATA SSD
1 x 200 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, VE
400GB Hot Plug 2.5-inch SATA SSD
1 x 400 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector VE
800GB Hot Plug 2.5-inch SATA SSD
1 x 800 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, VE
1.6TB Hot Plug 2.5-inch SATA SSD
1 x 1.6 TB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, VE
N8150-486
N8150-518
N8150-487
N8150-488
N8150-489
N8150-527
N8150-721
N8150-722
N8150-725
N8150-726
N8150-727
N8150-732
N8150-733
N8150-734
N8150-735
NOTE:




All hard drives within a RAID array should be of the same capacity.
Up to two kinds of drives selected from SAS 10K HDDs, SAS 15K HDDs, SATA HDDs, and SSDs can
be mixed in a system. However, SAS HDDs and SATA HDDs cannot be mixed in the same cage, and
HDDs in the same cage must have the same rotational speed.
To configure a large-capacity RAID array, it is recommended to configure in RAID 6 or RAID 60 in
order to minimize the risk of becoming multiple hard drives failure during the RAID rebuilding process.
The 2.5-inch SAS/SATA SSDs have limited lifetime. Refer to Endurance of SSD for details.
4.3.4
2.5-inch Drives (4)
Category
Drive
For 2.5-inch
drive cage:
4 slots
available
For optional
drive cage:
2 slots
available
NEC Corporation
SAS
HDD
(512n)
Product Name / Description
Part Number
300GB 10K Hot Plug 2.5-inch SAS HDD
1 x 300 GB SAS HDD, 2.5-inch, 12Gb/s, 10,000 rpm, 512n sector
450GB 10K Hot Plug 2.5-inch SAS HDD
1 x 450 GB SAS HDD, 2.5-inch, 12Gb/s, 10,000 rpm, 512n sector
600GB 10K Hot Plug 2.5-inch SAS HDD
1 x 600 GB SAS HDD, 2.5-inch, 12Gb/s, 10,000 rpm, 512n sector
900GB 10K Hot Plug 2.5-inch SAS HDD
1 x 900 GB SAS HDD, 2.5-inch, 12Gb/s, 10,000 rpm, 512n sector
1.2TB 10K Hot Plug 2.5-inch SAS HDD
1 x 1.2TB SAS HDD, 2.5-inch, 12Gb/s, 10,000 rpm, 512n sector
300GB 15K Hot Plug 2.5-inch SAS HDD
1 x 300 GB SAS HDD, 2.5-inch, 12Gb/s, 15,000 rpm, 512n sector
450GB 15K Hot Plug 2.5-inch SAS HDD
1 x 450 GB SAS HDD, 2.5-inch, 12Gb/s, 15,000 rpm, 512n sector
N8150-479
Revision 2.0 – April, 2016
N8150-480
N8150-481
N8150-482
N8150-483
N8150-485
N8150-486
23
SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110h-S
SAS
HDD
(4Kn)
SATA
HDD
(512n)
SAS
SSD
(eMLC)
SATA
SSD
(ME)
SATA
SSD
(VE)
600GB 15K Hot Plug 2.5-inch SAS HDD
N8150-518
1 x 600 GB SAS HDD, 2.5-inch, 12Gb/s, 15,000 rpm, 512n sector
1.8TB 10K Hot Plug 2.5-inch SAS HDD
N8150-490
1x 1.8TB SAS HDD, 2.5-inch, 12Gb/s, 10,000 rpm, 4Kn sector
250GB 7.2K Hot Plug 2.5-inch SATA HDD
1 x 250 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm, 512n sector
500GB 7.2K Hot Plug 2.5-inch SATA HDD
1 x 500 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm, 512n sector
1TB 7.2K Hot Plug 2.5-inch SATA HDD
1 x 1 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm, 512n sector
2TB 7.2K Hot Plug 2.5-inch SATA HDD
1 x 2 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm, 512n sector
N8150-487
200GB Hot Plug 2.5-inch SAS SSD
1 x 200 GB SAS SSD, eMLC, 2.5-inch, 12Gb/s, 512n sector
400GB Hot Plug 2.5-inch SAS SSD
1 x 400 GB SAS SSD, eMLC, 2.5-inch, 12Gb/s, 512n sector
200GB Hot Plug 2.5-inch SATA SSD
1 x 200 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, ME
400GB Hot Plug 2.5-inch SATA SSD
1 x 400 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, ME
800GB Hot Plug 2.5-inch SATA SSD
1 x 800 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, ME
200GB Hot Plug 2.5-inch SATA SSD
1 x 200 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, VE
400GB Hot Plug 2.5-inch SATA SSD
1 x 400 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector VE
800GB Hot Plug 2.5-inch SATA SSD
1 x 800 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, VE
1.6TB Hot Plug 2.5-inch SATA SSD
1 x 1.6 TB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, VE
N8150-721
N8150-488
N8150-489
N8150-527
N8150-722
N8150-725
N8150-726
N8150-727
N8150-732
N8150-733
N8150-734
N8150-735
NOTE:


The 4Kn sector drives are make-to-order products. Please consult your sales representative in regard
to production lead time.
When you select 4Kn sector HDD, confirm whether your applications support hard drives with 4 Kn
sector size. For more information, visit the NEC website at:
http://www.nec.com/en/global/prod/express/svropt/hdd/collateral/4KHDD_Precautions_EN.pdf





All hard drives within a RAID array should be of the same capacity.
Up to two kinds of drives selected from SAS 10K HDDs, SAS 15K HDDs, SATA HDDs, and SSDs can
be mixed in a system. However, SAS HDDs and SATA HDDs cannot be mixed in the same cage, and
HDDs in the same cage must have the same rotational speed.
Mix configurations of 4Kn sector HDDs and 512n sector HDDs are not supported.
To configure a large-capacity RAID array, it is recommended to configure in RAID 6 or RAID 60 in
order to minimize the risk of becoming multiple hard drives failure during the RAID rebuilding process.
The 2.5-inch SAS/SATA SSDs have limited lifetime. Refer to Endurance of SSD for details.
4.3.5
Non-hot Plug 3.5-inch Drives (1)
Category
Drive
2slots
available
NEC Corporation
SATA
HDD
(512n)
Product Name / Description
Part Number
500GB 7.2K non-Hot Plug 3.5-inch SATA HDD
1 x 500 GB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512n sector
1TB 7.2K non-Hot Plug 3.5-inch SATA HDD
1 x 1 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512n sector
2TB 7.2K non-Hot Plug 3.5-inch SATA HDD
1 x 2 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512n sector
N8150-526
Revision 2.0 – April, 2016
N8150-514
N8150-515
24
SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110h-S
3TB 7.2K non-Hot Plug 3.5-inch SATA HDD
1 x 3 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512n sector
4TB 7.2K non-Hot Plug 3.5-inch SATA HDD
1 x 4 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512n sector
N8150-516
N8150-517
NOTE:

Hot plug insertion/removal is not supported with the embedded SATA Non-RAID controller.
4.3.6
Non-hot Plug 3.5-inch Drives (2)
Category
Drive
2 slots
available
SATA
HDD
(512n)
SATA
HDD
(4Kn)
Product Name / Description
Part Number
500GB 7.2K non-Hot Plug 3.5-inch SATA HDD
1 x 500 GB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512n sector
1TB 7.2K non-Hot Plug 3.5-inch SATA HDD
1 x 1 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512n sector
2TB 7.2K non-Hot Plug 3.5-inch SATA HDD
1 x 2 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512n sector
3TB 7.2K non-Hot Plug 3.5-inch SATA HDD
1 x 3 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512n sector
4TB 7.2K non-Hot Plug 3.5-inch SATA HDD
1 x 4 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512n sector
6TB 7.2K non-Hot Plug 3.5-inch SATA HDD
1 x 6 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 4Kn sector
N8150-526
N8150-514
N8150-515
N8150-516
N8150-517
N8150-513
NOTE:



The 4Kn sector drives are make-to-order products. Please consult your sales representative in regard
to production lead time.
Mix configurations of 4Kn sector HDDs and 512n sector HDDs are not supported.
When you select 4Kn sector HDD, confirm whether your applications support hard drives with 4 Kn
sector size. For more information, visit the NEC website at:
http://www.nec.com/en/global/prod/express/svropt/hdd/collateral/4KHDD_Precautions_EN.pdf


All drives within a RAID array should be of the same capacity.
Embedded SATA RAID Controller does not support RAID 10 configured with 2TB or more HDDs.
5 Internal Optical Drive
Category
Product Name / Description
Part Number
Internal
Internal Slim DVD-ROM Drive
Slim DVD-ROM drive
Internal DVD Super Multi Drive
Slim DVD Super Multi drive, not including writing software
Optical Drive Bay Cover
Blank panel
External DVD-ROM Drive
DVD Super Multi drive, Bus powered, 1.5A required, not
including writing software
USB Extension Cable
For N8160-97F, USB2.0, 24cm
N8151-130
External
Cable
N8151-131F
N8151-133
N8160-97F
K410-351(00)
NOTE:




An optical drive is required for maintenance and OS installation.
Up to 1 optical drive can be connected.
N8151-133 Optical Drive Bay Cover must be installed when not installing any internal optical drives.
The USB cable length of N8160-97F is 20 cm. Please order the USB extension cable if necessary.
NEC Corporation
Revision 2.0 – April, 2016
25
SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110h-S
6 Internal RDX Drives
Category
Product Name / Description
Part Number
Controller
Internal USB Controller
1 x USB port
Internal USB cable
1x Internal USB3.0 to 1x USB 3.0 device
(Standard)
Internal RDX (USB)
N8151-105
Cable
Required
Drive
1 bays available
K410-352(00)
NOTE:

Optional 2.5-inch drive cage cannot be installed in the redundant power supply model with Internal
RDX drive.
7 PCI Card
7.1
Network Interface Controller
Category
Adapter
GbE
Product Name / Description
Part Number
1000BASE-T Adapter
Broadcom ® BCM5718 Gigabit Ethernet Controller
PCIe 2.0 x1
Dual Port 1000BASE-T Adapter
Broadcom ® BCM5718 Gigabit Ethernet Controller
PCIe 2.0 x1
Quad Port 1000BASE-T Adapter
Broadcom ® BCM5719 Gigabit Ethernet Controller
PCIe 2.0 x4
NOTE:
N8104-150
-
10GbE
SFP+
Module
NEC Corporation
N8104-149
N8104-129 SFP+ Module is required to connect with an optical cable.
Up to two SFP+ Modules can be installed.
Up to two adapters can be installed.
N8104-129 SFP+ Module is required to connect with an optical cable.
Dual Port 10GBASE-T Adapter
Intel® Ethernet Controller X540
PCIe 2.0(x8)
NOTE:
-
N8104-152
Network cables with RJ-45 plug covers cannot be used.
10GBASE SFP+ Adapter (SFP+/2ch)
Qlogic® NetXtreme II BCM57810 10G SFP+ Dual Port Network
Interface Card
PCIe 2.0 x8
NOTE:
-
N8104-151
N8104-153
N8103-184 and N8104-153 cannot be installed at the same time.
SFP+ Module (10G-SR)
1 x SFP+ Module for N8104-149
Revision 2.0 – April, 2016
N8104-129
26
SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110h-S
NIC Teaming feature – NIC Teaming and bonding features
See the table below for supported network interfaces and OS combinations.
Windows Server 2008 R2 supports BASP (Broadcom Advanced Server Program) teaming while Windows
Server 2012 or later and Linux support teaming with bonding function supported by OS.
Network Interface
Team
Operating Systems
1GbE NIC
Embedded 1GbE NIC and
N8104-150/-151/-152
Up to four teams per one system
Up to four ports per one team
Windows Server 2008 R2
Windows Server 2012
Windows Server 2012 R2
Red Hat Enterprise Linux
10GbE NIC
N8104-149
Up to two teams per one system
Up to two ports per one team
Windows Server 2008 R2
Windows Server 2012
Windows Server 2012 R2
Red Hat Enterprise Linux
10GbE NIC
N8104-153
Up to one teams per one system
Up to two ports per one team
Windows Server 2012
Windows Server 2012 R2
Red Hat Enterprise Linux
NOTE:

The network interfaces for a teaming must be the same.

When 10GbE and 1GbE LAN teams are mixed, the teams must be up to four per one system.
Using iSCSI
See the table below for supported network interfaces and OS combinations.
Category
Network Interface
Operating Systems
1GbE
Embedded 1GbE NIC/
N8104-150/-151/-152
Windows Server 2008 R2, Windows Server 2012,
Windows Server 2012 R2, Red Hat Enterprise Linux 6, Red Hat
Enterprise Linux 7, VMware
10GbE
N8104-149
Windows Server 2008 R2, Windows Server 2012,
Windows Server 2012 R2, Red Hat Enterprise Linux 6, Red Hat
Enterprise Linux 7, VMware
N8104-153
Windows Server 2012,Windows Server 2012 R2, Red Hat Enterprise
Linux 6, Red Hat Enterprise Linux 7, VMware
NOTE:

NIC Teaming feature is not supported on iSCSI interfaces.
7.2
SAS Controller
Product Name / Description
Part Number
SAS Controller
LSI SAS9212-4i4e Host Bus Adapter
6Gb/s SAS, Int. 4 / Ext. 4, 7-pin SATA / SFF-8088, PCIe 2.0 x8
SAS Controller
LSI SAS9300-8e Host Bus Adapter
12Gb/s SAS, Int. 4 / Ext. 4, 7-pin SATA / SFF-8088, PCIe 3.0 x8
NOTE:
N8103-142
-
N8103-184
N8103-184 and N8104-153 cannot be installed at the same time.
NEC Corporation
Revision 2.0 – April, 2016
27
SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110h-S
7.3
Graphics Accelerator
Product Name / Description
Part Number
Graphics Accelerator
NVIDIA NVS315
PCIe 2.0(x16), 1xDVI-VGA conversion connector, DMS-59-DVI-I cable included
N8105-48
NOTE:

VGA connector of the server cannot be used when this option is installed.

Remote KVM cannot be used when this option is installed.

Dual display configuration is possible with this option.
7.4
Serial Port Adapter
Product Name / Description
Part Number
Serial Port Adapter
Serial port fixed to PCI bracket
N8117-01A
NOTE:

Up to one Serial Port Adapter can be installed.
8 Other Add-in Components
8.1
Trusted Platform Module Kit
Product Name / Description
Part Number
Trusted Platform Module Kit
TPM 2.0 module
N8115-23
NOTE:

The kit is not available in China.

The kit is not removable after attachment.

"TPM Support" in BIOS setup menu must be activated prior to use of this kit.

To use Windows BitLocker drive encryption, be sure to keep the "recovery password" of BitLocker
function. The recovery password is required to restore data for hardware replacement during a
system error.
8.2
Internal Flash Memory
Product Name / Description
Part Number
VMware ESXi support kit
Internal USB flash memory to install VMware ESXi system
N8106-011
NOTE:

The kit does not include VMware ESXi installation media and license.
NEC Corporation
Revision 2.0 – April, 2016
28
SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110h-S
8.3
High Temperature Support Option
Product Name / Description
Part Number
High temperature resistant Kit
Required for high temperature operation over 40°C (up to 48°C)
N8181-140F
NOTE:

To apply this option, there are some configuration limitations below.
Required System Configuration:
- See Supported PCI cards and Installable Slots for the PCI slot limitation.
- Internal RDX or optional 2.5-inch drive cage must not be installed.
8.4
Flash FDD
Choose the Flash FDD if you need to prepare an alternative device for a floppy drive.
Product Name / Description
Part Number
Flash FDD
USB flash emulating USB floppy disk, Native capacity 1.44 MB
N8160-96
NOTE:

Up to one derive can be connected
8.5
Input Devices
Product Name / Description
Part Number
Keyboard and Mouse Pack (US)
1 x 104-keys White USB keyboard, 1 x USB White Optical Wheel Mouse
(Standard)
9 Add-on Components
9.1
Server Management License
The server integrates the EXPRESSSCOPE Engine 3 as standard. Refer to Server Management for the
standard management features. For more extensive remote KVM and remote media features, choose the
following kit.
Product Name / Description
Part Number
Remote KVM and Media License Kit
License for one server.
Remote KVM and remote media are enabled regardless of OS status.
Remote KVM:
N8115-04
-
Displays a graphics console on the web browser of the remote terminal (PC/server).
Controls keyboard and mouse via the remote terminals' web browser
Remote media:
-
Enables the user to use the CD / DVD / FD / Flash memory of the remote terminals (PC/server) as
if accessing the local drives.
NOTE:

Remote KVM and remote media features are not available for virtual machines.
NEC Corporation
Revision 2.0 – April, 2016
29
SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110h-S
9.2
Dust Proof Kit
The server supports the dust resistant feature. Choose the following kit to install the system in dusty
places.
Category
Product Name / Description
Part Number
Front Bezel
Dust Proof Bezel
Including 1 set of dust proof filter
N8146-74
Dust Proof Bezel
Including1 set of filter replacement sensors, 1 set of dust proof
filter
Dust proof filter (5 pcs.)
For Dust Proof filter
Removal capacity of particles : Up to 1 μm-sized
Filter replacement Sensor
For N8146-74 Dust Proof Bezel
N8146-75
Filter
Sensor
9.3
N8147-23
N8146-76
Tamper Proof Power Button Covers
Product Name / Description
Part Number
Tamper Proof Cover
For Standard Bezel
Tamper proof cover to prevent erroneous operation of a power button
N8146-77
NOTE:

The Tamper Proof Cover is not available for Dust Proof Bezel.
9.4
Rack Conversion Kit
Product Name / Description
Part Number
Rack Conversion Kit
Convert to 3U form factor
N8143-120
9.5
Medium and Cartridge
Category
RDX
NEC Corporation
HDD
Product Name
Drive supported
Part Number
RDX Cartridge (320GB)
N8151-105
N8153-01
RDX Cartridge (500GB)
N8151-105
N8153-02
RDX Cartridge (1TB)
N8151-105
N8153-03
RDX Cartridge (2TB)
N8151-105
N8153-09
Revision 2.0 – April, 2016
30
SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110h-S
References
Boot Mode Setting
The server supports Legacy mode and UEFI mode (default) as an OS Boot Mode. See the table below for
the Boot Mode and X2APIC setting for each Operating System. As the default settings at the factory, UEFI
mode is set as OS Boot mode and X2APIC is enabled. Refer to the User’s Guide and change the settings
before installing an Operating System requiring Legacy Mode.
Operating System
Supported Boot Mode
Supported X2APIC Setting
Windows Server 2008 R2 (x64)
Legacy
Disabled
Windows Server 2012
UEFI
Enabled
Windows Server 2012 R2
UEFI
Enabled
Red Hat Enterprise Linux 6(x86_64)
UEFI
Enabled
Red Hat Enterprise Linux 7
UEFI
Enabled
VMware ESXi 5.5 Update3
Legacy
Disabled
VMware ESXi 6 Update1
Legacy
Disabled
NEC Corporation
Revision 2.0 – April, 2016
31
SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110h-S
Server Management
The EXPRESSSCOPE Engine 3, integrated into the server, provides superior remote control and system
management features listed in the table below.
Standard
Hardware
monitoring
1
Temperature/hard drive /fan/voltage/power
consumption/ System LAN/degeneration/
1
(memory/hard drive )


Hardware configuration information collection


Hardware event log collection


Boot monitoring
BIOS/POST stall, Booting, OS stall, shutdown
3
3
Alerting
HW error, Boot error and OS panic
(by SNMP, E-Mail)


Remote KVM
(via LAN)
POST/BIOS setup, ROM utility
2

Panic screen, Boot screen
CUI-based screen (OS console)
Remote control
(via LAN)
2
3
4
5

2, 4, 5

2, 5


GUI-based screen (OS console)
-

Remote Screen Video Capture
-

Remote reset/power on-off/ dump


Remote Power Capping


BIOS/BMC FW update


Remote BIOS setup(partial configuration only)


OS shutdown

3
3
Remote media (CD/DVD/FD/USB)
-

CLP (Command Line Protocol) (DMTF compliant)


Remote control via Web browser (multi user login
at the same time)


Scheduling (without UPS, require NEC ESMPRO
Manager)
3
3
BIOS setting by using XML file


Maintenance
EXPRESSSCOPE® Profile key
(Backup/restore BIOS/BMC setup information)


Others
Set automatic IP address via DNS/DHCP


LDAP/Active Directory verification/user control


Clock synchronization of main unit and the RTC


Access log collection


Industry
Standard
1
With Remote KVM
and Media License kit
IPMI support
2.0
2.0
The feature is not supported on non-hot plug 3.5-inch drive.
The optional serial port is not available for the feature.
The feature is not supported on VMware systems.
Monitoring boot screens is not supported on VMware systems.
In VMware systems, only the direct console user interface is supported.
NEC Corporation
Revision 2.0 – April, 2016
32
SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110h-S
Endurance of SSD
The 2.5-inch SAS/SATA SSDs have limited lifetime, which can only be written a limited number of times
before it fails.
The warranty period of SSD is the stated period of warranty or until the total bytes of written value (PBW)
exceeds the limit value, whichever occurs first. It is recommended to check the total bytes of written value
periodically.
Refer to the table below for the write endurance (PBW and DWPD), warranty period and monitoring tool.
SSD Lifetime
Part
Number
Product Name
PBW
DWPD
Period
Monitoring Tool
N8150-721
200GB Hot Plug
2.5-inch SAS SSD
3.6PBW
10 Times
3 Years
N8150-722
400GB Hot Plug
2.5-inch SAS SSD
7.3PBW
10 Times
3 Years
Universal RAID Utility,
EXPRESSBUILDER
(System Test and
Diagnostics)
SAS SSD
SATA SSD (Middle Endurance)
N8150-725
200GB Hot Plug
2.5-inch SATA SSD
3.6PBW
10 Times
3 Years
N8150-726
400GB Hot Plug
2.5-inch SATA SSD
7.3PBW
10 Times
3 Years
N8150-727
800GB Hot Plug
2.5-inch SATA SSD
14.6PBW
10 Times
3 Years
SATA SSD (Low Endurance)
N8150-732
200GB Hot Plug
2.5-inch SATA SSD
1.1PBW
3 Times
3 Years
N8150-733
400GB Hot Plug
2.5-inch SATA SSD
3.0PBW
3 Times
3 Years
N8150-734
800GB Hot Plug
2.5-inch SATA SSD
5.3PBW
3 Times
3 Years
N8150-735
1.6TB Hot Plug
2.5-inch SATA SSD
10.7PBW
3 Times
3 Years





PBW(Peta-Bytes Write): Total amount of data that can be written into the SSD. 1PB=1,000TB.
DWPD(Drive Writes per Day): Rewrite capacity of the SSD per day.
Check the lifetime of SSD by monitoring tool regularly.
It is recommended to replace the SSD before it reaches its end of life. For repurchase, please contact your sales representative.
For detailed operating methods of monitoring tool, refer to the User’s Guide.
NEC Corporation
Revision 2.0 – April, 2016
33
SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110h-S
OS Support Matrix for PCI Cards and Embedded Controllers
ESXi 5.5
ESXi 6.0
RHEL 6 x64
RHEL 7
WS 2008 R2
WS 2012
WS 2012 R2
Part Number
Product Name
-
Embedded SATA non-RAID Controller

-
Embedded SATA RAID Controller
-
-
Embedded 1GbE NIC

N8103-188
RAID Controller (RAID 0/1)

N8103-176
RAID Controller (1GB, RAID 0/1)

N8103-177
RAID Controller (1GB, RAID 0/1/5/6)
      
N8103-178
RAID Controller (2GB, RAID 0/1/5/6)
     
N8105-48
Graphics Accelerator
 -
N8104-153
Dual Port 10GBASE-T Adapter
  -
N8104-149
10GBASE SFP+ Adapter (SFP+/2ch)
     
N8103-184
SAS Controller
  -
N8103-142
SAS Controller
     
N8104-152
Quad Port 1000BASE-T Adapter
     
N8104-151
Dual Port 1000BASE-T Adapter
     
N8104-150
1000BASE-T Adapter
     
-
-
-
-
-
-
-
-
-
   
   
Supported PCI cards and Installable Slots
Slots
1
Part Number
Product Name
#1
#2
#3
N8103-188
RAID Controller (RAID 0/1)
-
-
-
(1)
N8103-176
RAID Controller (1GB, RAID 0/1)
-
-
-
(1)
N8103-177
RAID Controller (1GB, RAID 0/1/5/6)
-
-
-
(1)
N8103-178
RAID Controller (2GB, RAID 0/1/5/6)
-
-
-
(1)
N8105-48
Graphics Accelerator
-
-
(1) -
N8104-153
Dual Port 10GBASE-T Adapter
-
-
(1)  (2)
N8104-149
10GBASE SFP+ Adapter (SFP+/2ch)
-
-
(1)  (2)
N8103-184
SAS Controller
-
-
(1)  (2)
N8103-142
SAS Controller
-
(3)  (1)  (2)
N8104-152
Quad Port 1000BASE-T Adapter
(1)  (3)  -
N8104-151
Dual Port 1000BASE-T Adapter
(2) (4)
(1) (3)
N8104-150
1000BASE-T Adapter
(2) (4)
(1) (3)
N8117-01A
Serial Port Adapter
(2) (4)
(1) (3)
1
1
1
1
1
#4
1
1
(2)
Not installable when high temperature support option is applied.
NOTE:

The number between parentheses shows the population priority (recommendation). For example,
NEC Corporation
Revision 2.0 – April, 2016
34
SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110h-S


install N8103-176 in the slot #4 and N8104-151 in the slot #3 when you have those cards.
For VMware ESXi 5.5/6.0, there are some limitations as follows:
- When any of N8104-149/-153/ is installed, N8104-152 cannot be installed and the number of
installable N8104-150/-151 is limited up to one.
For the configuration limitation for VMware ESXi, refer to the following documents.
VMware ESXi5.5
https://www.vmware.com/pdf/vsphere5/r55/vsphere-55-configuration-maximums.pdf
VMware ESXi6.0
https://www.vmware.com/pdf/vsphere6/r60/vsphere-60-configuration-maximums.pdf
Secure Boot Mode
This server supports Secure Boot. It is supported with UEFI Boot mode and protects the security by only
allowing software programs with digital signature to run. The supported operating systems, software, and
boot devices are below. The default setting of Secure Boot is disabled. Keep the setting disabled to use
other operating systems and/or software.
Supported OS and Software for Secure Boot Mode
Operating System
Supported Boot Mode
Secure Boot Mode
Windows Server 2012
UEFI

Windows Server 2012 R2
UEFI

Software Related to Boot
Supported Boot Mode
Secure Boot Mode
System Diagnostics Utility
UEFI

EXPRESSBUILDER
UEFI

Supported Boot Device for Secure Boot Mode
Supported Boot Device
Part Number
RAID controller (RAID0/1)
N8103-188
RAID controller (1GB, RAID0/1)
N8103-176
RAID controller (1GB, RAID0/1/5/6)
N8103-177
RAID controller (2GB, RAID0/1/5/6)
N8103-178
RAID controller (2GB, RAID0/1/5/6)
N8103-179
NEC Corporation
Revision 2.0 – April, 2016
35
SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110h-S
Copyright Notice and Liability Disclaimer
The information contained herein is subject to change without notice.
Microsoft and Windows Server are either registered trademarks or trademarks of Microsoft Corporation in
the United States and/or other countries
Intel , Xeon and Pentium are registered trademarks or trademarks of Intel Corporation or its subsidiaries in
the United States and other countries.
Linux is a trademark of Linus Torvalds.
Red Hat is a registered trademark of Red Hat, Inc. in the U.S.
All other products, brands, or trade names used in this document are trademarks or registered trademarks
of their respective holders.
NEC shall not be liable for technical or editorial errors or omissions contained herein.
For hard drive capacity measurements, 1 GB = 1 billion bytes. Actual formatted capacity is less.
The USB interface is not guaranteed to work properly for all USB devices.
NEC Corporation
Revision 2.0 – April, 2016
36
SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110h-S
Revision History
Revision
Date
Description
2.0
April 26, 2016
New products added:
Dust Proof Bezel N8146-75
Filter replacement Sensor N8146-76
Others:
N8103-184 and N8104-153 cannot be installed at the same time
Changed the Installable slot information for N8103-184
Added a note for Windows Server 2008 R2 installation
Added SATA SSDs for the RAID configuration for RAID 0/1 (Embedded
SATA RAID) (4.3.2)
Added a note for Graphics Accelerator N8105-48
1.1
February 2, 2016
Corrected typos and errors.
1.0
January 22, 2016
Initial release
NEC Corporation
Revision 2.0 – April, 2016
37