NEC Express5800/T110h-S System Configuration Guide Introduction This document contains product and configuration information that will enable you to configure your system. The guide will ensure fast and proper configuration of your NEC Express5800 server. April 26, 2016 Revision 2.0 NEC Corporation SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110h-S Contents TECHNICAL SPECIFICATION ........................................................................................ 3 Key Features .......................................................................................................................................... 3 Specification .......................................................................................................................................... 3 EXTERNAL VIEWS ......................................................................................................... 7 Front View .............................................................................................................................................. 7 Rear Views ............................................................................................................................................. 8 Dimensions (mm) .................................................................................................................................. 9 CONFIGURATION DIAGRAM ....................................................................................... 12 Expansion Slots .................................................................................................................................. 13 SERVER CONFIGURATION ......................................................................................... 14 1 2 3 4 5 6 7 8 9 Base Models ................................................................................................................................. 14 Processor ..................................................................................................................................... 14 Memory ......................................................................................................................................... 14 Maximum Available Memory .......................................................................................................... 15 Internal Hard Disk Drives ............................................................................................................ 16 4.1 RAID Configuration .............................................................................................................. 16 4.2 Required Components for RAID Configuration ................................................................... 18 4.3 Supported Drives ................................................................................................................. 22 Internal Optical Drive ................................................................................................................... 25 Internal RDX Drives ..................................................................................................................... 26 PCI Card ........................................................................................................................................ 26 7.1 Network Interface Controller ................................................................................................ 26 7.2 SAS Controller ..................................................................................................................... 27 7.3 Graphics Accelerator ........................................................................................................... 28 7.4 Serial Port Adapter .............................................................................................................. 28 Other Add-in Components .......................................................................................................... 28 8.1 Trusted Platform Module Kit ................................................................................................ 28 8.2 Internal Flash Memory ......................................................................................................... 28 8.3 High Temperature Support Option ....................................................................................... 29 8.4 Flash FDD............................................................................................................................ 29 8.5 Input Devices ....................................................................................................................... 29 Add-on Components ................................................................................................................... 29 9.1 Server Management License............................................................................................... 29 9.2 Dust Proof Kit ...................................................................................................................... 30 9.3 Tamper Proof Power Button Covers .................................................................................... 30 9.4 Rack Conversion Kit ............................................................................................................ 30 9.5 Medium and Cartridge ......................................................................................................... 30 REFERENCES............................................................................................................... 31 Boot Mode Setting .............................................................................................................................. 31 Server Management ............................................................................................................................ 32 Endurance of SSD ............................................................................................................................... 33 OS Support Matrix for PCI Cards and Embedded Controllers ....................................................... 34 Supported PCI cards and Installable Slots....................................................................................... 34 Copyright Notice and Liability Disclaimer ........................................................................................ 36 REVISION HISTORY ..................................................................................................... 37 NEC Corporation Revision 2.0 – April, 2016 2 SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110h-S Technical Specification Key Features Ultra compact form of 98 mm in width, 13 liters in volume High performance with the latest Intel® Xeon® processor E3-1200 v5 processor family Up to 64 GB of high speed DDR4 memory Agent-less management with improved EXPRESSCOPE Engine 3 Wide range of operating ambient temperature from 5 to 48°C (41 to 118°F) Specification (1 / 2) Model T110h-S Part Number Processor N8100-2327F, N8100-2328F Type Intel® Pentium® processor G4400 Intel® Xeon® processor E3-1220 v5 Intel® Xeon® processor E3-1230 v5 Clock speed 3.30 GHz 3.00 GHz 3.40 GHz Number of Processors 1 Cache 3 MB 8MB Cores and Threads 2C / 2T 4C / 4T Chipset Memory Internal Storage Intel® C236 Chipset Type DDR4-2133 ECC Unbuffered DIMM Standard Capacity 0 GB Maximum Capacity 64 GB (4 x 16 GB) Standard Capacity 0 GB Maximum Capacity 16 TB (2 x 6 TB + 2x 2TB) Disk Controller SATA : 6 Gb/s (Integrated) SATA/SAS : 6/12 Gb/s (Optional) RAID SATA : RAID 0/1/10 (Standard ) SATA/SAS : RAID 0/1/5/6/10/50/60 (Optional) Hot Plug Supported with hot plug drive bay Optical Disk Drive Optional 3.5-inch Media Bays 2 Disk Drive Bays 2 or 4 or 6 1 Expansion Slots Video 4C / 8T Total: 4 slots available 1 PCIe 3.0 x16 (x16 connector) 1 PCIe 3.0 x4 (x8 connector) 1 PCIe 3.0 x2 (x8 connector) 1 PCIe 3.0 x1 (x8 connector) Controller (VRAM) Integrated in Server Management Controller (32MB) Resolution / Color 1600 x 1200 / 16.7M 2 Interfaces 1 VGA (15-pin mini D-sub,1 rear) 1 to 2 Serial (9-pin mini D-sub, RS232-C, 1 to 2 rear) 6 USB 3.0 (2 front, 4 rear) (plus 1 internal USB 3.0) 2 1000BASE-T LAN connector (RJ-45, 2 rear) 1 1000BASE-T LAN connector for Management (RJ-45, 1 rear) Server Management EXPRESSSCOPE Engine 3 NEC Corporation Revision 2.0 – April, 2016 3 SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110h-S 1 2 3 4 5 Model T110h-S System Fan Standard Power Supply 1 x 250 Watt 80 PLUS® Platinum certified non-hot plug PSU 2 x 460 Watt 80 PLUS® Platinum certified Hot plug PSU 100-240 VAC ± 10% 50 / 60 Hz ± 3 Hz Power (Max. Config, Idling) Consumption Power (Max. Config, Consumption Operating) Acoustic Noise Minimum Config. (Sound Pressure Maximum Config. 3 Level) Dimensions (W x D x H ) 94 VA / 94 Watt 96 VA / 96 Watt 97 VA / 96 Watt 165 VA / 164 Watt 204 VA / 203 Watt 233 VA / 232 Watt Weight (Minimum / Maximum) 8 kg / 11.5 kg, 17.64 lbs. / 25.35 lbs. Temperature, Relative Humidity (non-condensing) Operating: 5° to 40 ° C / 41° to 104 ° F or 5 to 48°C / 41 to 118°F (Optional), 20 to 80% Non-Operating: -10° to 55° C / 14° to 131° F, 20 to 80% Regulatory and Safety FCC, c-UL, CE, CB, RoHS, WEEE, BSMI, CCC Operating Systems and Virtualization Software Microsoft® Windows Server® 2008 R2 Standard Microsoft® Windows Server® 2008 R2 Enterprise Microsoft® Windows Server® 2012 Standard Microsoft® Windows Server® 2012 Datacenter Microsoft® Windows Server® 2012 R2 Standard Microsoft® Windows Server® 2012 R2 Datacenter 4 Red Hat Enterprise Linux 6.7 or later (x86_64) 4 Red Hat Enterprise Linux 7.2 or later 5 VMware ESXi 5.5 Update 3 5 VMware ESXi 6.0 Update 1 26.1 dB 35.8 dB 98.0 x 386.5 x 341.0 mm / 3.9 x 15.2 x 13.4 in Embedded SATA RAID controller is supported only on limited operating systems. Maximum resolution available via EXPRESSSCOPE Engine 3 remote console is 1280 x 1024 / 65K colors. Noise emission was measured in accordance with ISO 7779, at 25°C. The actual value may vary by the operating environment. For Linux support, contact your sales representative or go to the NEC website at: http://www.nec.com/global/prod/express/linux/index.html Support on Xeon and Core processor systems only. (2 / 2) Model T110h-S Part Number Processor N8100-2327F, N8100-2328F Type Intel® Xeon® processor E3-1240L v5 Intel® Xeon® processor E3-1260L v5 Intel® Xeon® processor E3-1270 v5 Clock speed 2.10 GHz 2.90 GHz 3.60 GHz Number of Processors 1 Cache 8 MB Cores and Threads 4C / 8T Chipset Memory NEC Corporation Intel® C236 Chipset Type DDR4-2133 ECC Unbuffered DIMM Standard Capacity 0 GB Maximum Capacity 64 GB (4 x 16 GB) Revision 2.0 – April, 2016 4 SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110h-S Model Internal Storage T110h-S Standard Capacity 0 GB Maximum Capacity 16 TB (2 x 6 TB + 2x 2TB) Disk Controller SATA : 6 Gb/s (Integrated) SATA/SAS : 6/12 Gb/s (Optional) RAID SATA : RAID 0/1/10 (Standard ) SATA/SAS : RAID 0/1/5/6/10/50/60 (Optional) Hot Plug Supported with hot plug drive bay Optical Disk Drive Optional 3.5-inch Media Bays 2 Disk Drive Bays 2 or 4 or 6 1 Expansion Slots Video 1 2 3 Total: 4 slots available 1 PCIe 3.0 x16 (x16 connector) 1 PCIe 3.0 x4 (x8 connector) 1 PCIe 3.0 x2 (x8 connector) 1 PCIe 3.0 x1 (x8 connector) Controller (VRAM) Integrated in Server Management Controller (32MB) Resolution / Color 1600 x 1200 / 16.7M 2 Interfaces 1 VGA (15-pin mini D-sub,1 rear) 1 to 2 Serial (9-pin mini D-sub, RS232-C, 1 to 2 rear) 6 USB 3.0 (2 front, 4 rear) (plus 1 internal USB 3.0) 2 1000BASE-T LAN connector (RJ-45, 2 rear) 1 1000BASE-T LAN connector for Management (RJ-45, 1 rear) Server Management EXPRESSSCOPE Engine 3 System Fan Standard Power Supply 1 x 250 Watt 80 PLUS® Platinum certified non-hot plug PSU 2 x 460 Watt 80 PLUS® Platinum certified Hot plug PSU 100-240 VAC ± 10% 50 / 60 Hz ± 3 Hz Power (Max. Config, Idling) 94 VA / 94 Watt Consumption (Max. Config, Operating) Minimum Config. 153 VA / 152 Watt 96 VA / 95 Watt 185 VA / 184 Watt 232 VA / 230 Watt Acoustic Noise (Sound Pressure Maximum Config. 3 Level) Dimensions (W x D x H ) 26.1 dB Weight (Minimum / Maximum) 8 kg / 11.5 kg, 17.64 lbs. / 25.35 lbs. Temperature, Relative Humidity (non-condensing) Operating: 5° to 40 ° C / 41° to 104 ° F or 5 to 48°C / 41 to 118°F (Optional), 20 to 80% Non-Operating: -10° to 55° C / 14° to 131° F, 20 to 80% Regulatory and Safety FCC, c-UL, CE, CB, RoHS, WEEE, BSMI, CCC Operating Systems and Virtualization Software Microsoft® Windows Server® 2008 R2 Standard Microsoft® Windows Server® 2008 R2 Enterprise Microsoft® Windows Server® 2012 Standard Microsoft® Windows Server® 2012 Datacenter Microsoft® Windows Server® 2012 R2 Standard Microsoft® Windows Server® 2012 R2 Datacenter 4 Red Hat Enterprise Linux 6.7 or later (x86_64) 4 Red Hat Enterprise Linux 7.2 or later 5 VMware ESXi 5.5 Update 3 5 VMware ESXi 6.0 Update 1 35.8 dB 98.0 x 386.5 x 341.0 mm / 3.9 x 15.2 x 13.4 in Embedded SATA RAID controller is supported only on limited operating systems. Maximum resolution available via EXPRESSSCOPE Engine 3 remote console is 1280 x 1024 / 65K colors. Noise emission was measured in accordance with ISO 7779, at 25°C. The actual value may vary by the operating NEC Corporation Revision 2.0 – April, 2016 5 SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110h-S 4 5 environment. For Linux support, contact your sales representative or go to the NEC website at: http://www.nec.com/global/prod/express/linux/index.html Support on Xeon and Core processor systems only. NEC Corporation Revision 2.0 – April, 2016 6 SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110h-S External Views Front View A B C D F H E G I K J L M N Legend A. Power Button H. Global LED 1 B. Dump (NMI) Button I. Global LED 2 C. BMC Reset Button J. USB 3.0 Connectors Optical Disk Drive D. Power LED K. E. Power Capping LED L. Cover Key (2.5 inch Drive Configuration) F. STATUS LED 1 M. Drive Bay Cover STATUS LED 2 N. Stabilizer G. NEC Corporation Revision 2.0 – April, 2016 7 SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110h-S Rear Views Non-redundant power supply model Redundant power supply model A G B H C E D F Legend A. B. C. D. Serial Port Connector VGA Connector USB Connectors Management LAN Connector NEC Corporation E. F. G. H. Data LAN Connectors PCI Slots AC Inlet Power Supply Unit Revision 2.0 – April, 2016 8 SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110h-S Dimensions (mm) Standard Bezel Tower Orientation 98.0 347.1 386.5 395.4 200.0 Desktop Orientation 104.2 395.4 386.5 NEC Corporation Revision 2.0 – April, 2016 347.1 9 SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110h-S Dust Proof Bezel Tower Orientation (Non-redundant power supply) 98.0 347.1 423.7 200.0 415.7 Desktop Orientation (Non-redundant power supply) 104.2 423.7 415.7 NEC Corporation Revision 2.0 – April, 2016 347.1 10 SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110h-S Tower Orientation (Redundant power supply) 98.0 347.1 415.7 200.0 447.5 Desktop Orientation (Redundant power supply) 104.2 447.5 415.7 NEC Corporation Revision 2.0 – April, 2016 347.1 11 SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110h-S Configuration Diagram Non-redundant Power Supply Model Legend: Standard Components Mandatory Components Redundant Power Supply Model Legend: NEC Corporation Standard Components Mandatory Components Revision 2.0 – April, 2016 12 SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110h-S Expansion Slots Slot #1 Slot #2 Slot #3 Slot #4 Legend #1 PCIe 3.0 x2, x8 connector, Low Profile, up to 168mm length #2 PCIe 3.0 x1, x8 connector, Low Profile, up to 168mm length #3 PCIe 3.0 x16, x16 connector, Low Profile, up to 168mm length #4 PCIe 3.0 x4, x8 connector, Low Profile, up to 168mm length NEC Corporation Revision 2.0 – April, 2016 13 SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110h-S Server Configuration 1 Base Models Product Name / Description Part Number Express5800/T110h-S no Processor, no RAM, no Drive Cage, no HDD, no Optical Drive Including: 250 Watt non-hot plug power supply Express5800/T110h-S no Processor, no RAM, no Drive Cage, no HDD, no Optical Drive Including: 2x 460 Watt hot plug power supply N8100-2327F N8100-2328F NOTE: The base model must be ordered with a processor kit, memory, a drive cage, and an optical drive. For Windows Server 2008 R2 installation, EXPRESSBUILDER DVD is required. 2 Processor Available sockets: 1 Category Product Name / Description Part Number Processors Required Pentium G4400 Processor Kit Intel® Pentium ® Processor G4400 (3.3 GHz, 2C/2T, 3 MB) Xeon E3-1220v5 Processor Kit Intel® Xeon ® Processor E3-1220 v5 (3.0 GHz, 4C/4T, 8 MB) Xeon E3-1230 v5 Processor Kit Intel® Xeon ® Processor E3-1230 v5 (3.4 GHz, 4C/8T, 8 MB) Xeon E3-1240L v5 Processor Kit Intel® Xeon ® Processor E3-1240L v5 (2.1 GHz, 4C/8T, 8 MB) Xeon E3-1260L v5 Processor Kit Intel® Xeon ® Processor E3-1260L v5 (2.9 GHz, 4C/8T, 8 MB) Xeon E3-1270 v5 Processor Kit Intel® Xeon ® Processor E3-1270 v5 (3.6 GHz, 4C/8T, 8 MB) N8101-939F N8101-941F N8101-942F N8101-943F N8101-944F N8101-945F NOTE: One processor kit from above must be installed. VMware ESXi is supported only on Xeon processor systems. 3 Memory Available slots: 4 Product Name / Description Part Number 4GB DDR4-2133 UNB Memory Kit 1 x 4GB Unbuffered ECC DIMM, DDR4-2133 8GB DDR4-2133 UNB Memory Kit 1 x 8GB Unbuffered ECC DIMM, DDR4-2133 16GB DDR4-2133 UNB Memory Kit 1 x 16GB Unbuffered ECC DIMM, DDR4-2133 N8102-656F N8102-657F N8102-658F NOTE: Minimum one memory kit must be installed. It is recommended to install memory kits in pairs of two identical DIMMs for dual-channel symmetric memory configurations to increase memory transfer speed. The memory requirement to run VMware ESXi™ are below: NEC Corporation Revision 2.0 – April, 2016 14 SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110h-S - VMware ESXi 5.5 : at least 5 GB - VMware ESXi 6.0 : at least 5 GB Maximum Available Memory See the table below for the maximum memory size that you can actually use on your system. Maximum Memory Size Supported by Operating Systems Maximum Available Memory 32 GB 32 GB 2 TB 64 GB Microsoft Windows Server 2012 Standard Microsoft Windows Server 2012 Datacenter 1 Microsoft Windows Server 2012 R2 Standard 1 Microsoft Windows Server 2012 R2 Datacenter 1 4 TB 64 GB Red Hat Enterprise Linux 6 (x86_64) Red Hat Enterprise Linux 7 6 TB 64 GB VMware ESXi 5.5 2 4 TB 64 GB 3 6 TB 64 GB Operating Systems Microsoft Windows Server 2008 R2 Standard 1 Microsoft Windows Server 2008 R2 Enterprise 1 VMware ESXi 6.0 1 2 3 1 The maximum available memory size of Hyper-V systems is below: - Windows Server 2008 R2 Standard : 32 GB - Windows Server 2008 R2 Enterprise : 1TB - Windows Server 2012 and Windows Server 2012 R2 : 4 TB Up to 1 TB of main memory is available to each virtual machine. Up to 4 TB of main memory is available to each virtual machine. NEC Corporation Revision 2.0 – April, 2016 15 SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110h-S 4 Internal Hard Disk Drives 4.1 RAID Configuration Refer to the section in accordance with your disk form factor and RAID configuration Slot 5 2.5-inch Drive Slot 4 4.1.1 Slot Slot Slot Slot Operating System 3 2 1 0 Supported RAID configuration RAID and Cache Windows Server 2008 R2 VMware ESXi 5.5 VMware ESXi 6 KVM in Red Hat Enterprise Linux 6 (x86_64) Windows Server 2012 Windows Server 2012 R2 Red Hat Enterprise Linux 6 (x86_64) without KVM Red Hat Enterprise Linux 7 Supported HDD/SSD Section Non-RAID (Embedded SATA) 4.2.1 4.3.1 RAID 0/1/10 No Cache 4.2.3 4.3.3 RAID 0/1/10 1GB Cache 4.2.4 RAID 5/6/50/60 1GB Cache 4.2.5 RAID 5/6/50/60 2GB Cache 4.2.6 Non-RAID (Embedded SATA) 4.2.1 4.3.1 RAID 0/1 (Embedded SATA RAID) 4.2.2 4.3.2 RAID 0/1/10 No Cache 4.2.3 4.3.4 RAID 0/1/10 1GB Cache 4.2.4 RAID 5/6/50/60 1GB Cache 4.2.5 RAID 5/6/50/60 2GB Cache 4.2.6 Non-RAID (Embedded SATA) 4.2.1 4.3.1 RAID 0/1/10 No Cache 4.2.3 4.3.4 RAID 0/1/10 1GB Cache 4.2.4 RAID 5/6/50/60 1GB Cache 4.2.5 RAID 5/6/50/60 2GB Cache 4.2.6 NOTE: Up to four drives can be installed when you choose the Embedded SATA Non-RAID controller. All drives within a RAID array should be of the same capacity and rotation speed. Up to two kinds of drives selected from SAS 10K HDDs, SAS 15K HDDs, SATA HDDs, and SSDs can be mixed in a system. However, SAS HDDs and SATA HDDs cannot be mixed in the same cage, and HDDs in the same cage must have the same rotational speed. Mix configurations of 4Kn sector HDDs and 512n sector HDDs are not supported. NEC Corporation Revision 2.0 – April, 2016 16 SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110h-S Internal RDX drive cannot be installed in the redundant power supply model with optional 2.5-inch drive cage. 3.5-inch Drive Operating System Slot 1 Slot 0 Slot 4 4.1.2 Slot 5 Supported RAID configuration RAID and Cache Supported HDD/SSD Section Windows Server 2008 R2 VMware ESXi 5.5 VMware ESXi 6 KVM in Red Hat Enterprise Linux 6 (x86_64) Non-RAID (Embedded SATA) 4.2.7 RAID 0/1/10 No Cache 4.2.9 RAID 0/1/10 1GB Cache 4.2.10 3.5-inch: 4.3.5 2.5-inch: 4.3.2 Windows Server 2012 Windows Server 2012 R2 Non-RAID (Embedded SATA) 4.2.7 4.3.6 RAID 0/1 (Embedded SATA RAID) 4.2.8 RAID 0/1/10 No Cache 4.2.9 RAID 0/1/10 1GB Cache 4.2.10 3.5-inch: 4.3.6 2.5-inch: 4.3.4 Non-RAID (Embedded SATA) 4.2.7 4.3.6 RAID 0/1/10 No Cache 4.2.9 RAID 0/1/10 1GB Cache 4.2.10 Red Hat Enterprise Linux 6 (x86_64) without KVM Red Hat Enterprise Linux 7 4.3.5 3.5-inch: 4.3.6 2.5-inch: 4.3.4 NOTE: All hard drives within a RAID array should be of the same capacity and rotation speed. 2.5-inch drives installed in the optional cage must be identical. Install an operating system in the 3.5-inch drives with this configuration. 2.5-inch drives cannot be set as hot-spare for the RAID group of 3.5-inch drives. Internal RDX drive cannot be installed in the redundant power supply model with optional 2.5-inch drive cage. Hot plug insertion/removal of any drive is not supported when both 3.5-inch and 2.5-inch drives are installed. NEC Corporation Revision 2.0 – April, 2016 17 SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110h-S 4.2 Required Components for RAID Configuration 4.2.1 Embedded SATA non-RAID Controller for 2.5-inch Drives Category Product Name / Description Part Number Storage Controller Embedded SATA Controller 4x 6Gb/s SATA Internal SATA Cable Mini-SAS to mini-SAS 2.5-inch Drive Cage 4 x 2.5-inch hot plug drive bays (Standard) Cable Drive Cage Required (Included in the Drive Cage) N8154-82F NOTE Hot plug insertion/removal is not supported with the embedded SATA non-RAID controller. 4.2.2 Embedded SATA RAID Controller for 2.5-inch Drives Category Product Name / Description Part Number Storage Controller Embedded SATA Controller 4x 6Gb/s SATA, RAID0/1/10 capable Internal SATA Cable Mini-SAS to mini-SAS 2.5-inch Drive Cage 4 x 2.5-inch hot plug drive bays (Standard) Cable Drive Cage Required (Included in the Drive Cage) N8154-82F NOTE All hard drives within a RAID array should be of the same capacity and rotation speed. 4.2.3 RAID 0/1 Controller without Cache for 2.5-inch Drives Category Product Name / Description Part Number Storage Controller Required RAID Controller (RAID 0/1) Avago(LSI) MegaRAID SAS 9341-8i RAID0/1/10, no memory cache, Int. 8, PCIe 3.0(x8), SAS 12Gb/s, SATA 6Gb/s Internal SATA Cable mini-SAS to mini-SAS, miniSAS – 2x Single SATA 2.5-inch Drive Cage 4 x 2.5-inch hot plug drive bays 2.5-Inch Hot Plug Drive Cage Kit 2x 2.5-inch hot plug drive bays Including 1x mini-SAS to 2x Single SATA cable N8103-188 Cable Drive Cage Required Optional Drive Cage (For more than 4 drives) (Included in the Drive Cage) N8154-82F N8154-83F NOTE: All drives within a RAID array should be of the same type, capacity and rotation speed. NEC Corporation Revision 2.0 – April, 2016 18 SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110h-S 4.2.4 RAID 0/1 Controller with 1 GB Cache for 2.5-inch Drives Category Product Name / Description Part Number Storage Controller Required RAID Controller (1GB, RAID 0/1) LSI MegaRAID SAS 9362-8i RAID0/1/10, 1GB, Int. 8, PCIe 3.0(x8), SAS 12Gb/s, SATA 6Gb/s Flash Backup Unit for LSI MegaRAID SAS 9362-8i 500mm Cable for Flash Backup Unit included Internal SATA Cable mini-SAS to mini-SAS, miniSAS – 2x Single SATA 2.5-inch Drive Cage 4 x 2.5-inch hot plug drive bays 2.5-Inch Hot Plug Drive Cage Kit 2x 2.5-inch hot plug drive bays Including 1x mini-SAS to 2x Single SATA cable N8103-176 Flash Backup Recommended Cable Drive Cage Required Optional Drive Cage (For more than 4 drives) N8103-180 (Included in the Drive Cage) N8154-82F N8154-83F NOTE: All drives within a RAID array should be of the same type, capacity and rotation speed. 4.2.5 RAID 5/6 Controller with 1 GB Cache for 2.5-inch Drives Category Product Name / Description Part Number Storage Controller Required RAID Controller (1GB, RAID 0/1/5/6) LSI MegaRAID SAS 9362-8i RAID0/1/5/6/10/50/60, 1GB, Int. 8, PCIe 3.0(x8), SAS 12Gb/s, SATA 6Gb/s Flash Backup Unit for LSI MegaRAID SAS 9362-8i 500mm Cable for Flash Backup Unit included Internal SATA Cable mini-SAS to mini-SAS, miniSAS – 2x Single SATA 2.5-inch Drive Cage 4 x 2.5-inch hot plug drive bays 2.5-Inch Hot Plug Drive Cage Kit 2x 2.5-inch hot plug drive bays Including 1x mini-SAS to 2x Single SATA cable N8103-177 Flash Backup Recommended Cable Drive Cage Required Optional Drive Cage (For more than 4 drives) N8103-180 (Included in the Drive Cage) N8154-82F N8154-83F NOTE: All drives within a RAID array should be of the same type, capacity and rotation speed. NEC Corporation Revision 2.0 – April, 2016 19 SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110h-S 4.2.6 RAID 5/6 Controller with 2 GB Cache for 2.5-inch Drives Category Product Name / Description Part Number Storage Controller Required RAID Controller (2GB, RAID 0/1/5/6) LSI MegaRAID SAS 9362-8i RAID0/1/5/6/10/50/60, 2 GB, Int. 8, PCIe 3.0(x8), SAS 12Gb/s, SATA 6Gb/s Flash Backup Unit for LSI MegaRAID SAS 9362-8i 500mm Cable for Flash Backup Unit included Internal SATA Cable mini-SAS to mini-SAS, miniSAS – 2x Single SATA 2.5-inch Drive Cage 4 x 2.5-inch hot plug drive bays 2.5-Inch Hot Plug Drive Cage Kit 2x 2.5-inch hot plug drive bays Including 1x mini-SAS to 2x Single SATA cable N8103-178 Flash Backup Recommended Cable Drive Cage Required Optional Drive Cage (For more than 4 drives) N8103-180 (Included in the Drive Cage) N8154-82F N8154-83F NOTE: All drives within a RAID array should be of the same type, capacity and rotation speed. 4.2.7 Embedded SATA non-RAID Controller for 3.5-inch Drives Category Product Name / Description Part Number Storage Controller Embedded SATA Controller 4x 6Gb/s SATA Internal SAS/SATA Cable miniSAS to 2x Single SATA 3.5-inch Drive Cage 2 x 3.5-inch non hot plug (fixed) drive bays (Standard) Cable Drive Cage Required 4.2.8 (Included in the Drive Cage) N8154-84F Embedded SATA RAID Controller for 3.5-inch Drives Category Product Name / Description Part Number Storage Controller Embedded SATA Controller 4x 6Gb/s SATA Internal SAS/SATA Cable miniSAS to 2x Single SATA 3.5-inch Drive Cage 2 x 3.5-inch non hot plug (fixed) drive bays (Standard) Cable Drive Cage Required (Included in the Drive Cage) N8154-84F NOTE: All hard drives within a RAID array should be of the same capacity. NEC Corporation Revision 2.0 – April, 2016 20 SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110h-S 4.2.9 RAID 0/1 Controller without Cache for 3.5-inch Drives Category Product Name / Description Part Number Storage Controller Required RAID Controller (RAID 0/1) Avago(LSI) MegaRAID SAS 9341-8i RAID0/1/10, no memory cache, Int. 8, PCIe 3.0(x8), SAS 12Gb/s, SATA 6Gb/s RAID LED Cable N8103-188 Internal SAS/SATA Cable miniSAS to 2x Single SATA 3.5-inch Drive Cage 2 x 3.5-inch non hot plug (fixed) drive bays (Included in the Drive Cage) Cable Required Cable Drive Cage Required K410-293(00) N8154-84F NOTE: All hard drives within a RAID array should be of the same capacity. 4.2.10 RAID 0/1 Controller with 1 GB Cache for 3.5-inch and 2.5-inch Drives Category Product Name / Description Part Number Storage Controller Required RAID Controller (1GB, RAID 0/1) LSI MegaRAID SAS 9362-8i RAID0/1/10, 1GB, Int. 8, PCIe 3.0(x8), SAS 12Gb/s, SATA 6Gb/s Flash Backup Unit for LSI MegaRAID SAS 9362-8i 500mm Cable for Flash Backup Unit included RAID LED Cable N8103-176 Internal SATA Cable mini-SAS to 2x Single SATA, for 3.5-inch drive cage Internal SAS/SATA Cable mini-SAS to 2x Single SATA, for 2.5-inch drive cage 3.5-inch Drive Cage 2 x 3.5-inch non hot plug (fixed) drive bays 2.5-Inch Hot Plug Drive Cage Kit 2x 2.5-inch hot plug drive bays Including 1x mini-SAS to 2x Single SATA cable (Standard) Flash Backup Recommended Cable Required Cable Drive Cage Required Optional Drive Cage (For more than 2 drives) N8103-180 K410-293(00) (Included in the Drive Cage) N8154-84F N8154-83F NOTE: All hard drives within a RAID array should be of the same capacity. 2.5-inch drives installed in the optional cage must be identical. Hot plug insertion/removal of any drive is not supported when both 3.5-inch and 2.5-inch drives are installed. NEC Corporation Revision 2.0 – April, 2016 21 SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110h-S 4.3 Supported Drives 4.3.1 2.5-inch Drives (1) Category Drive For 2.5-inch drive cage: 4 slots available SATA HDD For optional drive cage: 2 slots available 4.3.2 Drive For 2.5-inch drive cage: 4 slots available For optional drive cage: 2 slots available SATA HDD (512n) SATA SSD (ME) SATA SSD (VE) 250GB 7.2K Hot Plug 2.5-inch SATA HDD 1 x 250 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm, 512n sector 500GB 7.2K Hot Plug 2.5-inch SATA HDD 1 x 500 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm, 512n sector 1TB 7.2K Hot Plug 2.5-inch SATA HDD 1 x 1 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm, 512n sector 2TB 7.2K Hot Plug 2.5-inch SATA HDD 1 x 2 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm, 512n sector N8150-487 N8150-488 N8150-489 N8150-527 Product Name / Description Part Number 250GB 7.2K Hot Plug 2.5-inch SATA HDD 1 x 250 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm, 512n sector 500GB 7.2K Hot Plug 2.5-inch SATA HDD 1 x 500 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm, 512n sector 1TB 7.2K Hot Plug 2.5-inch SATA HDD 1 x 1 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm, 512n sector 2TB 7.2K Hot Plug 2.5-inch SATA HDD 1 x 2 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm, 512n sector 200GB Hot Plug 2.5-inch SATA SSD 1 x 200 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, ME 400GB Hot Plug 2.5-inch SATA SSD 1 x 400 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, ME 800GB Hot Plug 2.5-inch SATA SSD 1 x 800 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, ME 200GB Hot Plug 2.5-inch SATA SSD 1 x 200 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, VE 400GB Hot Plug 2.5-inch SATA SSD 1 x 400 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, VE 800GB Hot Plug 2.5-inch SATA SSD 1 x 800 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, VE 1.6TB Hot Plug 2.5-inch SATA SSD 1 x 1.6 TB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, VE N8150-487 N8150-488 N8150-489 N8150-527 N8150-725 N8150-726 N8150-727 N8150-732 N8150-733 N8150-734 N8150-735 2.5-inch Drives (3) Category Drive For 2.5-inch drive cage: 4 slots available For optional drive cage: 2 slots available NEC Corporation Part Number 2.5-inch Drives (2) Category 4.3.3 Product Name / Description SAS HDD (512n) Product Name / Description Part Number 300GB 10K Hot Plug 2.5-inch SAS HDD 1 x 300 GB SAS HDD, 2.5-inch, 12Gb/s, 10,000 rpm, 512n sector 450GB 10K Hot Plug 2.5-inch SAS HDD 1 x 450 GB SAS HDD, 2.5-inch, 12Gb/s, 10,000 rpm, 512n sector 600GB 10K Hot Plug 2.5-inch SAS HDD 1 x 600 GB SAS HDD, 2.5-inch, 12Gb/s, 10,000 rpm, 512n sector 900GB 10K Hot Plug 2.5-inch SAS HDD 1 x 900 GB SAS HDD, 2.5-inch, 12Gb/s, 10,000 rpm, 512n sector 1.2TB 10K Hot Plug 2.5-inch SAS HDD 1 x 1.2TB SAS HDD, 2.5-inch, 12Gb/s, 10,000 rpm, 512n sector 300GB 15K Hot Plug 2.5-inch SAS HDD 1 x 300 GB SAS HDD, 2.5-inch, 12Gb/s, 15,000 rpm, 512n sector N8150-479 Revision 2.0 – April, 2016 N8150-480 N8150-481 N8150-482 N8150-483 N8150-485 22 SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110h-S SATA HDD (512n) SAS SSD (eMLC) SATA SSD (ME) SATA SSD (VE) 450GB 15K Hot Plug 2.5-inch SAS HDD 1 x 450 GB SAS HDD, 2.5-inch, 12Gb/s, 15,000 rpm, 512n sector 600GB 15K Hot Plug 2.5-inch SAS HDD 1 x 600 GB SAS HDD, 2.5-inch, 12Gb/s, 15,000 rpm, 512n sector 250GB 7.2K Hot Plug 2.5-inch SATA HDD 1 x 250 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm, 512n sector 500GB 7.2K Hot Plug 2.5-inch SATA HDD 1 x 500 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm, 512n sector 1TB 7.2K Hot Plug 2.5-inch SATA HDD 1 x 1 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm, 512n sector 2TB 7.2K Hot Plug 2.5-inch SATA HDD 1 x 2 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm, 512n sector 200GB Hot Plug 2.5-inch SAS SSD 1 x 200 GB SAS SSD, eMLC, 2.5-inch, 12Gb/s, 512n sector 400GB Hot Plug 2.5-inch SAS SSD 1 x 400 GB SAS SSD, eMLC, 2.5-inch, 12Gb/s, 512n sector 200GB Hot Plug 2.5-inch SATA SSD 1 x 200 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, ME 400GB Hot Plug 2.5-inch SATA SSD 1 x 400 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, ME 800GB Hot Plug 2.5-inch SATA SSD 1 x 800 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, ME 200GB Hot Plug 2.5-inch SATA SSD 1 x 200 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, VE 400GB Hot Plug 2.5-inch SATA SSD 1 x 400 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector VE 800GB Hot Plug 2.5-inch SATA SSD 1 x 800 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, VE 1.6TB Hot Plug 2.5-inch SATA SSD 1 x 1.6 TB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, VE N8150-486 N8150-518 N8150-487 N8150-488 N8150-489 N8150-527 N8150-721 N8150-722 N8150-725 N8150-726 N8150-727 N8150-732 N8150-733 N8150-734 N8150-735 NOTE: All hard drives within a RAID array should be of the same capacity. Up to two kinds of drives selected from SAS 10K HDDs, SAS 15K HDDs, SATA HDDs, and SSDs can be mixed in a system. However, SAS HDDs and SATA HDDs cannot be mixed in the same cage, and HDDs in the same cage must have the same rotational speed. To configure a large-capacity RAID array, it is recommended to configure in RAID 6 or RAID 60 in order to minimize the risk of becoming multiple hard drives failure during the RAID rebuilding process. The 2.5-inch SAS/SATA SSDs have limited lifetime. Refer to Endurance of SSD for details. 4.3.4 2.5-inch Drives (4) Category Drive For 2.5-inch drive cage: 4 slots available For optional drive cage: 2 slots available NEC Corporation SAS HDD (512n) Product Name / Description Part Number 300GB 10K Hot Plug 2.5-inch SAS HDD 1 x 300 GB SAS HDD, 2.5-inch, 12Gb/s, 10,000 rpm, 512n sector 450GB 10K Hot Plug 2.5-inch SAS HDD 1 x 450 GB SAS HDD, 2.5-inch, 12Gb/s, 10,000 rpm, 512n sector 600GB 10K Hot Plug 2.5-inch SAS HDD 1 x 600 GB SAS HDD, 2.5-inch, 12Gb/s, 10,000 rpm, 512n sector 900GB 10K Hot Plug 2.5-inch SAS HDD 1 x 900 GB SAS HDD, 2.5-inch, 12Gb/s, 10,000 rpm, 512n sector 1.2TB 10K Hot Plug 2.5-inch SAS HDD 1 x 1.2TB SAS HDD, 2.5-inch, 12Gb/s, 10,000 rpm, 512n sector 300GB 15K Hot Plug 2.5-inch SAS HDD 1 x 300 GB SAS HDD, 2.5-inch, 12Gb/s, 15,000 rpm, 512n sector 450GB 15K Hot Plug 2.5-inch SAS HDD 1 x 450 GB SAS HDD, 2.5-inch, 12Gb/s, 15,000 rpm, 512n sector N8150-479 Revision 2.0 – April, 2016 N8150-480 N8150-481 N8150-482 N8150-483 N8150-485 N8150-486 23 SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110h-S SAS HDD (4Kn) SATA HDD (512n) SAS SSD (eMLC) SATA SSD (ME) SATA SSD (VE) 600GB 15K Hot Plug 2.5-inch SAS HDD N8150-518 1 x 600 GB SAS HDD, 2.5-inch, 12Gb/s, 15,000 rpm, 512n sector 1.8TB 10K Hot Plug 2.5-inch SAS HDD N8150-490 1x 1.8TB SAS HDD, 2.5-inch, 12Gb/s, 10,000 rpm, 4Kn sector 250GB 7.2K Hot Plug 2.5-inch SATA HDD 1 x 250 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm, 512n sector 500GB 7.2K Hot Plug 2.5-inch SATA HDD 1 x 500 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm, 512n sector 1TB 7.2K Hot Plug 2.5-inch SATA HDD 1 x 1 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm, 512n sector 2TB 7.2K Hot Plug 2.5-inch SATA HDD 1 x 2 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm, 512n sector N8150-487 200GB Hot Plug 2.5-inch SAS SSD 1 x 200 GB SAS SSD, eMLC, 2.5-inch, 12Gb/s, 512n sector 400GB Hot Plug 2.5-inch SAS SSD 1 x 400 GB SAS SSD, eMLC, 2.5-inch, 12Gb/s, 512n sector 200GB Hot Plug 2.5-inch SATA SSD 1 x 200 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, ME 400GB Hot Plug 2.5-inch SATA SSD 1 x 400 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, ME 800GB Hot Plug 2.5-inch SATA SSD 1 x 800 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, ME 200GB Hot Plug 2.5-inch SATA SSD 1 x 200 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, VE 400GB Hot Plug 2.5-inch SATA SSD 1 x 400 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector VE 800GB Hot Plug 2.5-inch SATA SSD 1 x 800 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, VE 1.6TB Hot Plug 2.5-inch SATA SSD 1 x 1.6 TB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, VE N8150-721 N8150-488 N8150-489 N8150-527 N8150-722 N8150-725 N8150-726 N8150-727 N8150-732 N8150-733 N8150-734 N8150-735 NOTE: The 4Kn sector drives are make-to-order products. Please consult your sales representative in regard to production lead time. When you select 4Kn sector HDD, confirm whether your applications support hard drives with 4 Kn sector size. For more information, visit the NEC website at: http://www.nec.com/en/global/prod/express/svropt/hdd/collateral/4KHDD_Precautions_EN.pdf All hard drives within a RAID array should be of the same capacity. Up to two kinds of drives selected from SAS 10K HDDs, SAS 15K HDDs, SATA HDDs, and SSDs can be mixed in a system. However, SAS HDDs and SATA HDDs cannot be mixed in the same cage, and HDDs in the same cage must have the same rotational speed. Mix configurations of 4Kn sector HDDs and 512n sector HDDs are not supported. To configure a large-capacity RAID array, it is recommended to configure in RAID 6 or RAID 60 in order to minimize the risk of becoming multiple hard drives failure during the RAID rebuilding process. The 2.5-inch SAS/SATA SSDs have limited lifetime. Refer to Endurance of SSD for details. 4.3.5 Non-hot Plug 3.5-inch Drives (1) Category Drive 2slots available NEC Corporation SATA HDD (512n) Product Name / Description Part Number 500GB 7.2K non-Hot Plug 3.5-inch SATA HDD 1 x 500 GB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512n sector 1TB 7.2K non-Hot Plug 3.5-inch SATA HDD 1 x 1 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512n sector 2TB 7.2K non-Hot Plug 3.5-inch SATA HDD 1 x 2 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512n sector N8150-526 Revision 2.0 – April, 2016 N8150-514 N8150-515 24 SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110h-S 3TB 7.2K non-Hot Plug 3.5-inch SATA HDD 1 x 3 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512n sector 4TB 7.2K non-Hot Plug 3.5-inch SATA HDD 1 x 4 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512n sector N8150-516 N8150-517 NOTE: Hot plug insertion/removal is not supported with the embedded SATA Non-RAID controller. 4.3.6 Non-hot Plug 3.5-inch Drives (2) Category Drive 2 slots available SATA HDD (512n) SATA HDD (4Kn) Product Name / Description Part Number 500GB 7.2K non-Hot Plug 3.5-inch SATA HDD 1 x 500 GB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512n sector 1TB 7.2K non-Hot Plug 3.5-inch SATA HDD 1 x 1 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512n sector 2TB 7.2K non-Hot Plug 3.5-inch SATA HDD 1 x 2 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512n sector 3TB 7.2K non-Hot Plug 3.5-inch SATA HDD 1 x 3 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512n sector 4TB 7.2K non-Hot Plug 3.5-inch SATA HDD 1 x 4 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512n sector 6TB 7.2K non-Hot Plug 3.5-inch SATA HDD 1 x 6 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 4Kn sector N8150-526 N8150-514 N8150-515 N8150-516 N8150-517 N8150-513 NOTE: The 4Kn sector drives are make-to-order products. Please consult your sales representative in regard to production lead time. Mix configurations of 4Kn sector HDDs and 512n sector HDDs are not supported. When you select 4Kn sector HDD, confirm whether your applications support hard drives with 4 Kn sector size. For more information, visit the NEC website at: http://www.nec.com/en/global/prod/express/svropt/hdd/collateral/4KHDD_Precautions_EN.pdf All drives within a RAID array should be of the same capacity. Embedded SATA RAID Controller does not support RAID 10 configured with 2TB or more HDDs. 5 Internal Optical Drive Category Product Name / Description Part Number Internal Internal Slim DVD-ROM Drive Slim DVD-ROM drive Internal DVD Super Multi Drive Slim DVD Super Multi drive, not including writing software Optical Drive Bay Cover Blank panel External DVD-ROM Drive DVD Super Multi drive, Bus powered, 1.5A required, not including writing software USB Extension Cable For N8160-97F, USB2.0, 24cm N8151-130 External Cable N8151-131F N8151-133 N8160-97F K410-351(00) NOTE: An optical drive is required for maintenance and OS installation. Up to 1 optical drive can be connected. N8151-133 Optical Drive Bay Cover must be installed when not installing any internal optical drives. The USB cable length of N8160-97F is 20 cm. Please order the USB extension cable if necessary. NEC Corporation Revision 2.0 – April, 2016 25 SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110h-S 6 Internal RDX Drives Category Product Name / Description Part Number Controller Internal USB Controller 1 x USB port Internal USB cable 1x Internal USB3.0 to 1x USB 3.0 device (Standard) Internal RDX (USB) N8151-105 Cable Required Drive 1 bays available K410-352(00) NOTE: Optional 2.5-inch drive cage cannot be installed in the redundant power supply model with Internal RDX drive. 7 PCI Card 7.1 Network Interface Controller Category Adapter GbE Product Name / Description Part Number 1000BASE-T Adapter Broadcom ® BCM5718 Gigabit Ethernet Controller PCIe 2.0 x1 Dual Port 1000BASE-T Adapter Broadcom ® BCM5718 Gigabit Ethernet Controller PCIe 2.0 x1 Quad Port 1000BASE-T Adapter Broadcom ® BCM5719 Gigabit Ethernet Controller PCIe 2.0 x4 NOTE: N8104-150 - 10GbE SFP+ Module NEC Corporation N8104-149 N8104-129 SFP+ Module is required to connect with an optical cable. Up to two SFP+ Modules can be installed. Up to two adapters can be installed. N8104-129 SFP+ Module is required to connect with an optical cable. Dual Port 10GBASE-T Adapter Intel® Ethernet Controller X540 PCIe 2.0(x8) NOTE: - N8104-152 Network cables with RJ-45 plug covers cannot be used. 10GBASE SFP+ Adapter (SFP+/2ch) Qlogic® NetXtreme II BCM57810 10G SFP+ Dual Port Network Interface Card PCIe 2.0 x8 NOTE: - N8104-151 N8104-153 N8103-184 and N8104-153 cannot be installed at the same time. SFP+ Module (10G-SR) 1 x SFP+ Module for N8104-149 Revision 2.0 – April, 2016 N8104-129 26 SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110h-S NIC Teaming feature – NIC Teaming and bonding features See the table below for supported network interfaces and OS combinations. Windows Server 2008 R2 supports BASP (Broadcom Advanced Server Program) teaming while Windows Server 2012 or later and Linux support teaming with bonding function supported by OS. Network Interface Team Operating Systems 1GbE NIC Embedded 1GbE NIC and N8104-150/-151/-152 Up to four teams per one system Up to four ports per one team Windows Server 2008 R2 Windows Server 2012 Windows Server 2012 R2 Red Hat Enterprise Linux 10GbE NIC N8104-149 Up to two teams per one system Up to two ports per one team Windows Server 2008 R2 Windows Server 2012 Windows Server 2012 R2 Red Hat Enterprise Linux 10GbE NIC N8104-153 Up to one teams per one system Up to two ports per one team Windows Server 2012 Windows Server 2012 R2 Red Hat Enterprise Linux NOTE: The network interfaces for a teaming must be the same. When 10GbE and 1GbE LAN teams are mixed, the teams must be up to four per one system. Using iSCSI See the table below for supported network interfaces and OS combinations. Category Network Interface Operating Systems 1GbE Embedded 1GbE NIC/ N8104-150/-151/-152 Windows Server 2008 R2, Windows Server 2012, Windows Server 2012 R2, Red Hat Enterprise Linux 6, Red Hat Enterprise Linux 7, VMware 10GbE N8104-149 Windows Server 2008 R2, Windows Server 2012, Windows Server 2012 R2, Red Hat Enterprise Linux 6, Red Hat Enterprise Linux 7, VMware N8104-153 Windows Server 2012,Windows Server 2012 R2, Red Hat Enterprise Linux 6, Red Hat Enterprise Linux 7, VMware NOTE: NIC Teaming feature is not supported on iSCSI interfaces. 7.2 SAS Controller Product Name / Description Part Number SAS Controller LSI SAS9212-4i4e Host Bus Adapter 6Gb/s SAS, Int. 4 / Ext. 4, 7-pin SATA / SFF-8088, PCIe 2.0 x8 SAS Controller LSI SAS9300-8e Host Bus Adapter 12Gb/s SAS, Int. 4 / Ext. 4, 7-pin SATA / SFF-8088, PCIe 3.0 x8 NOTE: N8103-142 - N8103-184 N8103-184 and N8104-153 cannot be installed at the same time. NEC Corporation Revision 2.0 – April, 2016 27 SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110h-S 7.3 Graphics Accelerator Product Name / Description Part Number Graphics Accelerator NVIDIA NVS315 PCIe 2.0(x16), 1xDVI-VGA conversion connector, DMS-59-DVI-I cable included N8105-48 NOTE: VGA connector of the server cannot be used when this option is installed. Remote KVM cannot be used when this option is installed. Dual display configuration is possible with this option. 7.4 Serial Port Adapter Product Name / Description Part Number Serial Port Adapter Serial port fixed to PCI bracket N8117-01A NOTE: Up to one Serial Port Adapter can be installed. 8 Other Add-in Components 8.1 Trusted Platform Module Kit Product Name / Description Part Number Trusted Platform Module Kit TPM 2.0 module N8115-23 NOTE: The kit is not available in China. The kit is not removable after attachment. "TPM Support" in BIOS setup menu must be activated prior to use of this kit. To use Windows BitLocker drive encryption, be sure to keep the "recovery password" of BitLocker function. The recovery password is required to restore data for hardware replacement during a system error. 8.2 Internal Flash Memory Product Name / Description Part Number VMware ESXi support kit Internal USB flash memory to install VMware ESXi system N8106-011 NOTE: The kit does not include VMware ESXi installation media and license. NEC Corporation Revision 2.0 – April, 2016 28 SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110h-S 8.3 High Temperature Support Option Product Name / Description Part Number High temperature resistant Kit Required for high temperature operation over 40°C (up to 48°C) N8181-140F NOTE: To apply this option, there are some configuration limitations below. Required System Configuration: - See Supported PCI cards and Installable Slots for the PCI slot limitation. - Internal RDX or optional 2.5-inch drive cage must not be installed. 8.4 Flash FDD Choose the Flash FDD if you need to prepare an alternative device for a floppy drive. Product Name / Description Part Number Flash FDD USB flash emulating USB floppy disk, Native capacity 1.44 MB N8160-96 NOTE: Up to one derive can be connected 8.5 Input Devices Product Name / Description Part Number Keyboard and Mouse Pack (US) 1 x 104-keys White USB keyboard, 1 x USB White Optical Wheel Mouse (Standard) 9 Add-on Components 9.1 Server Management License The server integrates the EXPRESSSCOPE Engine 3 as standard. Refer to Server Management for the standard management features. For more extensive remote KVM and remote media features, choose the following kit. Product Name / Description Part Number Remote KVM and Media License Kit License for one server. Remote KVM and remote media are enabled regardless of OS status. Remote KVM: N8115-04 - Displays a graphics console on the web browser of the remote terminal (PC/server). Controls keyboard and mouse via the remote terminals' web browser Remote media: - Enables the user to use the CD / DVD / FD / Flash memory of the remote terminals (PC/server) as if accessing the local drives. NOTE: Remote KVM and remote media features are not available for virtual machines. NEC Corporation Revision 2.0 – April, 2016 29 SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110h-S 9.2 Dust Proof Kit The server supports the dust resistant feature. Choose the following kit to install the system in dusty places. Category Product Name / Description Part Number Front Bezel Dust Proof Bezel Including 1 set of dust proof filter N8146-74 Dust Proof Bezel Including1 set of filter replacement sensors, 1 set of dust proof filter Dust proof filter (5 pcs.) For Dust Proof filter Removal capacity of particles : Up to 1 μm-sized Filter replacement Sensor For N8146-74 Dust Proof Bezel N8146-75 Filter Sensor 9.3 N8147-23 N8146-76 Tamper Proof Power Button Covers Product Name / Description Part Number Tamper Proof Cover For Standard Bezel Tamper proof cover to prevent erroneous operation of a power button N8146-77 NOTE: The Tamper Proof Cover is not available for Dust Proof Bezel. 9.4 Rack Conversion Kit Product Name / Description Part Number Rack Conversion Kit Convert to 3U form factor N8143-120 9.5 Medium and Cartridge Category RDX NEC Corporation HDD Product Name Drive supported Part Number RDX Cartridge (320GB) N8151-105 N8153-01 RDX Cartridge (500GB) N8151-105 N8153-02 RDX Cartridge (1TB) N8151-105 N8153-03 RDX Cartridge (2TB) N8151-105 N8153-09 Revision 2.0 – April, 2016 30 SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110h-S References Boot Mode Setting The server supports Legacy mode and UEFI mode (default) as an OS Boot Mode. See the table below for the Boot Mode and X2APIC setting for each Operating System. As the default settings at the factory, UEFI mode is set as OS Boot mode and X2APIC is enabled. Refer to the User’s Guide and change the settings before installing an Operating System requiring Legacy Mode. Operating System Supported Boot Mode Supported X2APIC Setting Windows Server 2008 R2 (x64) Legacy Disabled Windows Server 2012 UEFI Enabled Windows Server 2012 R2 UEFI Enabled Red Hat Enterprise Linux 6(x86_64) UEFI Enabled Red Hat Enterprise Linux 7 UEFI Enabled VMware ESXi 5.5 Update3 Legacy Disabled VMware ESXi 6 Update1 Legacy Disabled NEC Corporation Revision 2.0 – April, 2016 31 SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110h-S Server Management The EXPRESSSCOPE Engine 3, integrated into the server, provides superior remote control and system management features listed in the table below. Standard Hardware monitoring 1 Temperature/hard drive /fan/voltage/power consumption/ System LAN/degeneration/ 1 (memory/hard drive ) Hardware configuration information collection Hardware event log collection Boot monitoring BIOS/POST stall, Booting, OS stall, shutdown 3 3 Alerting HW error, Boot error and OS panic (by SNMP, E-Mail) Remote KVM (via LAN) POST/BIOS setup, ROM utility 2 Panic screen, Boot screen CUI-based screen (OS console) Remote control (via LAN) 2 3 4 5 2, 4, 5 2, 5 GUI-based screen (OS console) - Remote Screen Video Capture - Remote reset/power on-off/ dump Remote Power Capping BIOS/BMC FW update Remote BIOS setup(partial configuration only) OS shutdown 3 3 Remote media (CD/DVD/FD/USB) - CLP (Command Line Protocol) (DMTF compliant) Remote control via Web browser (multi user login at the same time) Scheduling (without UPS, require NEC ESMPRO Manager) 3 3 BIOS setting by using XML file Maintenance EXPRESSSCOPE® Profile key (Backup/restore BIOS/BMC setup information) Others Set automatic IP address via DNS/DHCP LDAP/Active Directory verification/user control Clock synchronization of main unit and the RTC Access log collection Industry Standard 1 With Remote KVM and Media License kit IPMI support 2.0 2.0 The feature is not supported on non-hot plug 3.5-inch drive. The optional serial port is not available for the feature. The feature is not supported on VMware systems. Monitoring boot screens is not supported on VMware systems. In VMware systems, only the direct console user interface is supported. NEC Corporation Revision 2.0 – April, 2016 32 SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110h-S Endurance of SSD The 2.5-inch SAS/SATA SSDs have limited lifetime, which can only be written a limited number of times before it fails. The warranty period of SSD is the stated period of warranty or until the total bytes of written value (PBW) exceeds the limit value, whichever occurs first. It is recommended to check the total bytes of written value periodically. Refer to the table below for the write endurance (PBW and DWPD), warranty period and monitoring tool. SSD Lifetime Part Number Product Name PBW DWPD Period Monitoring Tool N8150-721 200GB Hot Plug 2.5-inch SAS SSD 3.6PBW 10 Times 3 Years N8150-722 400GB Hot Plug 2.5-inch SAS SSD 7.3PBW 10 Times 3 Years Universal RAID Utility, EXPRESSBUILDER (System Test and Diagnostics) SAS SSD SATA SSD (Middle Endurance) N8150-725 200GB Hot Plug 2.5-inch SATA SSD 3.6PBW 10 Times 3 Years N8150-726 400GB Hot Plug 2.5-inch SATA SSD 7.3PBW 10 Times 3 Years N8150-727 800GB Hot Plug 2.5-inch SATA SSD 14.6PBW 10 Times 3 Years SATA SSD (Low Endurance) N8150-732 200GB Hot Plug 2.5-inch SATA SSD 1.1PBW 3 Times 3 Years N8150-733 400GB Hot Plug 2.5-inch SATA SSD 3.0PBW 3 Times 3 Years N8150-734 800GB Hot Plug 2.5-inch SATA SSD 5.3PBW 3 Times 3 Years N8150-735 1.6TB Hot Plug 2.5-inch SATA SSD 10.7PBW 3 Times 3 Years PBW(Peta-Bytes Write): Total amount of data that can be written into the SSD. 1PB=1,000TB. DWPD(Drive Writes per Day): Rewrite capacity of the SSD per day. Check the lifetime of SSD by monitoring tool regularly. It is recommended to replace the SSD before it reaches its end of life. For repurchase, please contact your sales representative. For detailed operating methods of monitoring tool, refer to the User’s Guide. NEC Corporation Revision 2.0 – April, 2016 33 SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110h-S OS Support Matrix for PCI Cards and Embedded Controllers ESXi 5.5 ESXi 6.0 RHEL 6 x64 RHEL 7 WS 2008 R2 WS 2012 WS 2012 R2 Part Number Product Name - Embedded SATA non-RAID Controller - Embedded SATA RAID Controller - - Embedded 1GbE NIC N8103-188 RAID Controller (RAID 0/1) N8103-176 RAID Controller (1GB, RAID 0/1) N8103-177 RAID Controller (1GB, RAID 0/1/5/6) N8103-178 RAID Controller (2GB, RAID 0/1/5/6) N8105-48 Graphics Accelerator - N8104-153 Dual Port 10GBASE-T Adapter - N8104-149 10GBASE SFP+ Adapter (SFP+/2ch) N8103-184 SAS Controller - N8103-142 SAS Controller N8104-152 Quad Port 1000BASE-T Adapter N8104-151 Dual Port 1000BASE-T Adapter N8104-150 1000BASE-T Adapter - - - - - - - - - Supported PCI cards and Installable Slots Slots 1 Part Number Product Name #1 #2 #3 N8103-188 RAID Controller (RAID 0/1) - - - (1) N8103-176 RAID Controller (1GB, RAID 0/1) - - - (1) N8103-177 RAID Controller (1GB, RAID 0/1/5/6) - - - (1) N8103-178 RAID Controller (2GB, RAID 0/1/5/6) - - - (1) N8105-48 Graphics Accelerator - - (1) - N8104-153 Dual Port 10GBASE-T Adapter - - (1) (2) N8104-149 10GBASE SFP+ Adapter (SFP+/2ch) - - (1) (2) N8103-184 SAS Controller - - (1) (2) N8103-142 SAS Controller - (3) (1) (2) N8104-152 Quad Port 1000BASE-T Adapter (1) (3) - N8104-151 Dual Port 1000BASE-T Adapter (2) (4) (1) (3) N8104-150 1000BASE-T Adapter (2) (4) (1) (3) N8117-01A Serial Port Adapter (2) (4) (1) (3) 1 1 1 1 1 #4 1 1 (2) Not installable when high temperature support option is applied. NOTE: The number between parentheses shows the population priority (recommendation). For example, NEC Corporation Revision 2.0 – April, 2016 34 SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110h-S install N8103-176 in the slot #4 and N8104-151 in the slot #3 when you have those cards. For VMware ESXi 5.5/6.0, there are some limitations as follows: - When any of N8104-149/-153/ is installed, N8104-152 cannot be installed and the number of installable N8104-150/-151 is limited up to one. For the configuration limitation for VMware ESXi, refer to the following documents. VMware ESXi5.5 https://www.vmware.com/pdf/vsphere5/r55/vsphere-55-configuration-maximums.pdf VMware ESXi6.0 https://www.vmware.com/pdf/vsphere6/r60/vsphere-60-configuration-maximums.pdf Secure Boot Mode This server supports Secure Boot. It is supported with UEFI Boot mode and protects the security by only allowing software programs with digital signature to run. The supported operating systems, software, and boot devices are below. The default setting of Secure Boot is disabled. Keep the setting disabled to use other operating systems and/or software. Supported OS and Software for Secure Boot Mode Operating System Supported Boot Mode Secure Boot Mode Windows Server 2012 UEFI Windows Server 2012 R2 UEFI Software Related to Boot Supported Boot Mode Secure Boot Mode System Diagnostics Utility UEFI EXPRESSBUILDER UEFI Supported Boot Device for Secure Boot Mode Supported Boot Device Part Number RAID controller (RAID0/1) N8103-188 RAID controller (1GB, RAID0/1) N8103-176 RAID controller (1GB, RAID0/1/5/6) N8103-177 RAID controller (2GB, RAID0/1/5/6) N8103-178 RAID controller (2GB, RAID0/1/5/6) N8103-179 NEC Corporation Revision 2.0 – April, 2016 35 SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110h-S Copyright Notice and Liability Disclaimer The information contained herein is subject to change without notice. Microsoft and Windows Server are either registered trademarks or trademarks of Microsoft Corporation in the United States and/or other countries Intel , Xeon and Pentium are registered trademarks or trademarks of Intel Corporation or its subsidiaries in the United States and other countries. Linux is a trademark of Linus Torvalds. Red Hat is a registered trademark of Red Hat, Inc. in the U.S. All other products, brands, or trade names used in this document are trademarks or registered trademarks of their respective holders. NEC shall not be liable for technical or editorial errors or omissions contained herein. For hard drive capacity measurements, 1 GB = 1 billion bytes. Actual formatted capacity is less. The USB interface is not guaranteed to work properly for all USB devices. NEC Corporation Revision 2.0 – April, 2016 36 SYSTEM CONFIGRATION GUIDE – NEC Express5800/T110h-S Revision History Revision Date Description 2.0 April 26, 2016 New products added: Dust Proof Bezel N8146-75 Filter replacement Sensor N8146-76 Others: N8103-184 and N8104-153 cannot be installed at the same time Changed the Installable slot information for N8103-184 Added a note for Windows Server 2008 R2 installation Added SATA SSDs for the RAID configuration for RAID 0/1 (Embedded SATA RAID) (4.3.2) Added a note for Graphics Accelerator N8105-48 1.1 February 2, 2016 Corrected typos and errors. 1.0 January 22, 2016 Initial release NEC Corporation Revision 2.0 – April, 2016 37