PSC-10 Series
Type
Approved
OUTPUT
E361935
E205412
Features:
ENERGY
SAVER
•
•
•
•
•
•
•
•
•
•
•
•
Universal AC input (88-264V AC)
Protections: Short Circuit / Overload / Overvoltage
Brown-out protection
Installed on DIN rail TS35 / 7.5 or 15
True DC OK signal output
All wiring 105°C long life electrolytic capacitors
High operation temperature up to 70°C
Withstands 2G vibration test
High efficiency, long life and high reliability
3 year warranty
UL1310 Class 2 Power unit / LPS pass
UL508 (Industrial control equipment) listed
Cat. No.
PSC-1012
PSC-1015
PSC-1024
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
RIPPLE & NOISE (max)
12V
0.84A
0~0.84A
10.08W
100mVp-p
15V
0.67A
0~0.67A
10.05W
100mVp-p
24V
0.42A
0~0.42A
10.08W
120mVp-p
Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1µF & 47µF parallel capacitor
VOLTAGE ADJ. RANGE
VOLTAGE TOLERANCE
10.8-13.2V
±1.0%
13.5-16.5V
±1.0%
21.6-26.4V
±1.0%
Tolerance: includes set up tolerance, line regulation and load regulation.
INPUT
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
±1.0%
±1.0%
±1.0%
±1.0%
< 800ms, < 100ms/230V AC at full load
> 32ms / 230V AC; > 16ms / 115V AC at full load
88V~264VAC; 124V~370VDC
±1.0%
±1.0%
Derating may be needed under low input voltages. Please check the derating curve for more details.
PROTECTION
FREQUENCY RANGE
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
OVERLOAD PROTECTION
47~63Hz
81%
0.23A/115VAC; 0.17A/230VAC
15A / 115V AC; 30A / 230V AC
< 1mA/ 230VAC
81%
81%
> 102% rated output power
Protection type: Constant current limiting, recovers automatically after fault condition is removed.
OVERVOLTAGE PROTECTION
115%-150% rated output voltage
Protection type: Latch-off mode.
ENVIRONMENT
SAFETY & EMC
OTHERS
OVER TEMPERATURE PROTECTION
Power supply shut down at 70˚C constant current limiting / output voltage goes to 0;
re-power on to recover
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP. / HUMIDITY
TEMP. COEFFICIENT
VIBRATION
-20 ~ +70˚C (Refer to output load derating curve)
20 ~ 90% RH non-condensing
-40 ~ +85˚C; 10 ~ 95% RH
±0.03% / ˚C (0 ~ 50˚C)
10 ~ 500Hz, 2G 10min. / 1cycle, 60 min. each long X,Y, Z axes
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMI CONDUCTION & RADIATION
HARMONIC CURRENT
EMS IMMUNITY
UL508, TUV EN60950-1:2006+A11, UL1310 NEC class 2 compliant
I/P-O/P: 3KVAC (4242DC) I/P-FG: 1.5KVAC (2121DC) 1 minute
I/P-O/P, I/P-FG, O/P-FG: 100M Ohms/500VDC
EN55022:2006+A1:2007 Class B
EN61000-3-2:2006 Class A, EN61000-3-3:2008
EN61204-3:2000, EN55024:1998+A1:2001+A2:2003 light industry level, criteria A
The power supply is considered a component which will installed into a final equipment. The final equipment must be re-confirmed
that is still meets EMC directives.
DC OK Signal
MTBF
DIMENSION
PACKING
CONNECTION
COOLING
Open collector. Max: 40mA
562.7K hrs MIL-HDBK-217K
23x90x99 mm (WxHxD)
0.13Kg/48 pcs./7.44Kg
I/P 3 poles, O/P: 3 poles screw DIN terminal
Free air convection
All parameters NOT specially mentioned are measured at 230V AC input, rated load and 25˚C of ambient temperature.
20
For the latest on Altech Power Supplies please visit www.altechcorp.com/power.
PowerSupplies_2013.QXD_PowerSupplies(v5).QXD 9/18/13 5:03 PM Page 21
PSC-10 Series
Type
Approved
E361935
E205412
ENERGY
SAVER
Mechanical Specification
Unit : mm / inch
23
99
Terminal Pin. No Assign. (TB1)
90
Assignment
FG
AC/N
AC/L
Pin No.
1
2
3
Terminal Pin. No Assign. (TB2)
Pin No. Assignment
4
DC OUTPUT +V
DC OUTPUT -V
5
DC OK SIGNAL
6
5 5
Application of DC OK Active Signal
(a)5V s ignal
(b)LE D
DC OK
(c)R elay
DC OK
Mode l
R
5.1V
V-
R
12V
>1.5KΩ
15V
>2KΩ
24V
>3.9KΩ
DC OK
R
V-
Mode l
R
12V
>2.4KΩ
15V
>3KΩ
24V
>4.7KΩ
R e la y
RL
V-
Mode l
R
12V
>700Ω
15V
>700Ω
24V
>1.2KΩ
Block Diagram
DC O K
DC O K
R E C T IF IE R S
&
F I LT E R
E MI
F I LT E R
I /P
R E C T IF IE R S
&
F I LT E R
P OWE R
S W IT C H IN G
+V
-V
O.C .P
D E T E C T IO N
C IR C U IT
O .L .P .
C O NT R O L
O .V .P .
Derating Curve
Load V .S Temp.
Load V .S I/P V oltage
Ta=25°C
100
100
90
Load (%)
Load (%)
80
60
80
70
60
40
50
20
-20
40
0
10
20
30
40
50
Ambient Temperature (°C)
60
70
85
100
110
120
264 VAC
Input Voltage(VAC) 60Hz
Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490
21
PowerSupplies_2013.QXD_PowerSupplies(v5).QXD 9/18/13 5:03 PM Page 22
PSC-20 Series
Type
Approved
OUTPUT
E361935
E205412
Features:
ENERGY
SAVER
•
•
•
•
•
•
•
•
•
•
•
•
Universal AC input (88-264V AC)
Protections: Short Circuit / Overload / Overvoltage
Brown-out protection
Installed on DIN rail TS35 / 7.5 or 15
True DC OK signal output
All wiring 105°C long life electrolytic capacitors
High operation temperature up to 70°C
Withstands 2G vibration test
High efficiency, long life and high reliability
3 year warranty
UL1310 Class 2 Power unit / LPS pass
UL508 (Industrial control equipment) listed
Cat. No.
PSC-2012
PSC-2015
PSC-2024
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
RIPPLE & NOISE (max)
12V
1.7A
0~1.7A
20.4W
100mVp-p
15V
1.4A
0~1.4A
21W
100mVp-p
24V
1A
0~1A
24W
120mVp-p
Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1µF & 47µF parallel capacitor
VOLTAGE ADJ. RANGE
VOLTAGE TOLERANCE
10.8-13.2V
±1.0%
13.5-16.5V
±1.0%
21.6-26.4V
±1.0%
Tolerance: includes set up tolerance, line regulation and load regulation.
INPUT
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
±1.0%
±1.0%
±1.0%
±1.0%
< 800ms, < 100ms/230V AC at full load
> 32ms / 230V AC; > 16ms / 115V AC at full load
88V~264VAC; 124V~370VDC
±1.0%
±1.0%
Derating may be needed under low input voltages. Please check the derating curve for more details.
PROTECTION
FREQUENCY RANGE
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
OVERLOAD PROTECTION
47~63Hz
83%
0.45A/115VAC; 0.32A/230VAC
20A / 115V AC; 40A / 230V AC
< 1mA/ 230VAC
85%
86%
> 105% rated output power
Protection type: Constant current limiting, recovers automatically after fault condition is removed.
OVERVOLTAGE PROTECTION
115%-150% rated output voltage
Protection type: Latch-off mode.
ENVIRONMENT
SAFETY & EMC
OTHERS
OVER TEMPERATURE PROTECTION
Power supply shut down at 70˚C constant current limiting / output voltage goes to 0;
re-power on to recover
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP. / HUMIDITY
TEMP. COEFFICIENT
VIBRATION
-20 ~ +70˚C (Refer to output load derating curve)
20 ~ 90% RH non-condensing
-40 ~ +85˚C; 10 ~ 95% RH
±0.03% / ˚C (0 ~ 50˚C)
10 ~ 500Hz, 2G 10min. / 1cycle, 60 min. each long X,Y, Z axes
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMI CONDUCTION & RADIATION
HARMONIC CURRENT
EMS IMMUNITY
UL508, TUV EN60950-1:2006+A11, UL1310 NEC class 2 compliant
I/P-O/P: 4242DC I/P-FG: 2121DC 1 minute
I/P-O/P, I/P-FG, O/P-FG: 100M Ohms/500VDC
EN55022:2006+A1:2007 Class B
EN61000-3-2:2006 Class A, EN61000-3-3:2008
EN61204-3:2000, EN55024:1998+A1:2001+A2:2003 light industry level, criteria A
The power supply is considered a component which will installed into a final equipment. The final equipment must be re-confirmed
that is still meets EMC directives.
DC OK Signal
MTBF
DIMENSION
PACKING
CONNECTION
COOLING
Open collector. Max: 40mA
120.4K HRS MIL-HDBK-217 (25˚C)
131.3K HRS MIL-HDBK-217 (25˚C)
23x90x99 mm (WxHxD)
0.14Kg/48 pcs./7.92Kg
I/P 3 poles, O/P: 3 poles screw DIN terminal
Free air convection
125.9K HRS MIL-HDBK-217 (25˚C)
All parameters NOT specially mentioned are measured at 230V AC input, rated load and 25˚C of ambient temperature.
22
For the latest on Altech Power Supplies please visit www.altechcorp.com/power.
PowerSupplies_2013.QXD_PowerSupplies(v5).QXD 9/18/13 5:03 PM Page 23
PSC-20 Series
Type
Approved
E361935
E205412
ENERGY
SAVER
Mechanical Specification
Unit : mm / inch
23
99
Terminal Pin. No Assign. (TB1)
Pin No.
1
2
3
90
Assignment
FG
AC/N
AC/L
Terminal Pin. No Assign. (TB2)
Pin No. Assignment
DC OUTPUT +V
4
DC OUTPUT -V
5
DC OK SIGNAL
6
5 5
Application of DC OK Active Signal
(a)5V s ignal
(b)LE D
DC OK
(c)R elay
DC OK
Mode l
R
12V
5.1V
V-
R
DC OK
R
≥1 . 5 K Ω
Mode l
12V
Mode l
R
≥2 . 4 K Ω
15V
≥2 K Ω
15V
≥3 K Ω
24V
≥3 . 9 K Ω
24V
≥4 . 7 K Ω
V-
R e la y
12V
RL
V-
R
≥7 0 0 Ω
15V
≥7 0 0 Ω
24V
≥1 . 2 K Ω
Block Diagram
DC O K
DC O K
R E C T IF IE R S
&
F I LT E R
E MI
F I LT E R
I /P
R E C T IF IE R S
&
F I LT E R
P OWE R
S W IT C H IN G
+V
-V
O.C .P
D E T E C T IO N
C IR C U IT
O .L .P .
C O NT R O L
O .V .P .
Derating Curve
Load V .S Temp.
Load V .S I/P V oltage
Ta=25°C
100
100
90
Load (%)
Load (%)
80
60
80
70
60
40
50
20
-20
40
0
10
20
30
40
50
Ambient Temperature (°C)
60
70
85
100
110
120
264 VAC
Input Voltage(VAC)60Hz
Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490
23
PowerSupplies_2013.QXD_PowerSupplies(v5).QXD 9/18/13 5:03 PM Page 24
PSC-40 Series
Type
Approved
OUTPUT
E361935
E205412
Features:
•
•
•
•
•
•
•
•
•
•
•
•
ENERGY
SAVER
Universal AC input (88-264V AC)
Protections: Short Circuit / Overload / Overvoltage
Brown-out protection
Installed on DIN rail TS35 / 7.5 or 15
True DC OK signal output
All wiring 105°C long life electrolytic capacitors
High operation temperature up to 70°C
Withstands 2G vibration test
High efficiency, long life and high reliability
3 year warranty
UL1310 Class 2 Power unit / LPS pass
UL508 (Industrial control equipment) listed
Cat. No.
PSC-4012
PSC-4015
PSC-4024
PSC-4048
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
RIPPLE & NOISE (max)
12V
3.4A
0 ~ 3.4A
40.8W
100mVp-p
15V
2.7A
0 ~ 2.7A
40.5W
100mVp-p
24V
1.7A
0 ~ 1.7A
40.8W
120mVp-p
48V
0.85A
0 ~ 0.85A
40.8W
180mVp-p
Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1µF & 47µF parallel capacitor
VOLTAGE ADJ. RANGE
VOLTAGE TOLERANCE
10.8 ~ 13.2V
±1.0%
13.5 ~ 16.5V
±1.0%
21.6 ~ 26.4V
±1.0%
43.2 ~ 52.8V
±1.0%
Tolerance: includes set up tolerance, line regulation and load regulation.
INPUT
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
±1.0%
±1.0%
±1.0%
±1.0%
< 800ms, < 50ms / 230VAC at full load
> 32ms / 230VAC; >16ms / 115VAC at full load
88 ~ 264VAC; 124 ~ 370VDC
±1.0%
±1.0%
±1.0%
±1.0%
Derating may be needed under low input voltages. Please check the derating curve for more details.
FREQUENCY RANGE
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
PROTECTION
OVERLOAD PROTECTION
47~63Hz
84%
84%
0.8 A / 115VAC; 0.4A / 230VAC
COLD START 30A / 115VAC; 60A / 230VAC
< 1mA/ 230VAC
84%
85%
> 105% rated output power
Protection type: Constant current limiting, recovers automatically after fault condition is removed.
OVERVOLTAGE PROTECTION
115% ~ 150% rated output voltage
Protection type: latch-off mode
ENVIRONMENT
SAFETY & EMC
OTHERS
OVER TEMPERATURE PROTECTION
Power supply shut down at 70˚C constant current limiting / output voltage goes to 0;
re-power on to recover
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP. / HUMIDITY
TEMP. COEFFICIENT
VIBRATION
-20 ~ +70˚C (Refer to output load derating curve)
20 ~ 90% RH non-condensing
-40 ~ +85˚C; 10 ~ 95% RH
±0.03% / ˚C (0 ~ 50˚C)
10 ~ 500Hz, 2G 10min. / 1cycle, 60 min. each long X,Y, Z axes
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMI CONDUCTION & RADIATION
HARMONIC CURRENT
EMS IMMUNITY
UL508, TUV EN60950-1:2006+A11, UL1310 NEC class 2 compliant
I/P-O/P: 4242DC I/P-FG: 2121DC 1 minute
I/P-O/P, I/P-FG, O/P-FG: 100M Ohms/500VDC
EN55022: 2006 Class B
EN61000-3-2: 2006 Class A, EN61000-3-3: 1995+A1: 2001+A2: 2005
EN61204-3:2000, EN55024:1998+A1:2001+A2:2003 light industry level, criteria A
The power supply is considered a component which will installed into a final equipment. The final equipment must be re-confirmed
that is still meets EMC directives.
DC OK Signal
MTBF
DIMENSION
PACKING
CONNECTION
COOLING
Relay contact (30VDC / 1A, 120VAC / 1A)
947.2K hrs MIL-HDBK-217K
40x90x99 mm (WxHxD)
0.28Kg/27 pcs./8.76Kg
I/P 3 poles, O/P: 6 poles screw DIN terminal
Free air convection
All parameters NOT specially mentioned are measured at 230V AC input, rated load and 25˚C of ambient temperature.
24
For the latest on Altech Power Supplies please visit www.altechcorp.com/power.
PowerSupplies_2013.QXD_PowerSupplies(v5).QXD 9/18/13 5:03 PM Page 25
PSC-40 Series
Type
Approved
E361935
E205412
ENERGY
SAVER
Mechanical Specification
Unit : mm / inch
40
99
Terminal Pin. No Assign. (TB1)
Assignment
FG
AC/N
AC/L
90
Pin No.
1
2
3
Terminal Pin. No Assign. (TB2)
Pin No.
1,2
3,4
5,6
Assignment
DC OUTPUT +V
DC OUTPUT -V
DC OK RELAY CONTACT
N
L
Block Diagram
DC O K
R E C T IF IE R S
&
F I LT E R
E MI
F I LT E R
I /P
R E C T IF IE R S
&
F I LT E R
P OWE R
S W IT C H IN G
+V
-V
O .C .P .
DC O K
D E T E C T IO N
C IR C U IT
O .L .P .
C O NT R O L
O .V .P .
DC OK Relay Contact
Contact Close
When the output voltage reaches the adjusted output voltage
Contact Open
When the output voltage drop below 90% rated output voltage
Contact Ratings (max.)
30V / 1A resistive load
Derating Curve
Load V .S Temp.
Load V .S I/P V oltage
Ta=25°C
100
100
90
Load (%)
Load (%)
80
60
80
70
60
40
50
20
-20
40
0
10
20
30
40
50
Ambient Temperature (°C)
60
70
85
100
110
120
264 VAC
Input Voltage(VAC)60Hz
Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490
25
PowerSupplies_2013.QXD_PowerSupplies(v5).QXD 9/18/13 5:03 PM Page 26
PSC-60 Series
Type
Approved
OUTPUT
E361935
E205412
Features:
•
•
•
•
•
•
•
•
•
•
•
•
ENERGY
SAVER
Universal AC input (88-264V AC)
Protections: Short Circuit / Overload / Overvoltage
Brown-out protection
Installed on DIN rail TS35 / 7.5 or 15
True DC OK signal output
All wiring 105°C long life electrolytic capacitors
High operation temperature up to 70°C
Withstands 2G vibration test
High efficiency, long life and high reliability
3 year warranty
UL1310 Class 2 Power unit / LPS pass
UL508 (Industrial control equipment) listed
Cat. No.
PSC-6012
PSC-6015
PSC-6024
PSC-6048
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
RIPPLE & NOISE (max)
12V
5A
0 ~ 5A
60W
100mVp-p
15V
4A
0 ~ 4A
60W
100mVp-p
24V
2.5A
0 ~ 2.5A
60W
120mVp-p
48V
1.25A
0 ~ 1.25A
60W
180mVp-p
Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1µF & 47µF parallel capacitor
VOLTAGE ADJ. RANGE
VOLTAGE TOLERANCE
10.8 ~ 13.2V
±1.0%
13.5 ~ 16.5V
±1.0%
21.6 ~ 26.4V
±1.0%
43.2 ~ 52.8V
±1.0%
Tolerance: includes set up tolerance, line regulation and load regulation.
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
±1.0%
±1.0%
±1.0%
±1.0%
< 800ms, < 50ms / 230VAC at full load
±1.0%
±1.0%
±1.0%
±1.0%
Length of set up time is measured at sold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
INPUT
HOLD UP TIME (Typ.)
VOLTAGE RANGE
> 32ms / 230VAC; >16ms / 115VAC at full load
88 ~ 264VAC; 124 ~ 370VDC
Derating may apply in low input voltage. Please check the derating curve for more details.
PROTECTION
FREQUENCY RANGE
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
OVER LOAD PROTECTION
47~63Hz
86%
87%
1.3 A / 115VAC; 0.6A / 230VAC
COLD START 30A / 115VAC; 60A / 230VAC
<1mA / 230VAC
87%
88%
> 102% rated output power
Protection type: Constant current limiting, recovers automatically after fault condition is removed
OVER VOLTAGE PROTECTION
115% ~ 150% rated output voltage
Protection type: latch-off mode
ENVIRONMENT
SAFETY & EMC
OTHERS
OVER TEMPERATURE PROTECTION
Power supply shut down at 70˚C constant current limiting / output voltage goes to 0;
re-power on to recover
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP. / HUMIDITY
TEMP. COEFFICIENT
VIBRATION
-20 ~ +70˚C (Refer to output load derating curve)
20 ~ 90% RH non-condensing
-40 ~ +85˚C; 10 ~ 95% RH
±0.03% / ˚C (0 ~ 50˚C)
10 ~ 500Hz, 2G 10min. / 1cycle, 60 min. each long X,Y, Z axes
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMI CONDUCTION & RADIATION
HARMONIC CURRENT
EMS IMMUNITY
UL508, TUV EN60950-1:2006+A11, UL1310 NEC class 2 compliant
I/P-O/P: 4242DC, I/P-FG: 2121DC 1minute
I/P-O/P, I/P-FG, O/P-FG: 100M Ohms/500VDC
EN55022: 2006 Class B
EN61000-3-2: 2006 Class A, EN61000-3-3: 1995+A1: 2001+A2: 2005
EN61204-3: 2000, EN55024: 1998+A1:2001+A2: 2003 light industry level, criteria A
The power supply is considered a component which will installed into a final equipment. The final equipment must be re-confirmed
that is still meets EMC directives.
DC OK Signal
MTBF
DIMENSION
PACKING
CONNECTION
COOLING
Relay contact (24VDC / 1A, 120VAC / 1A)
944.6K HRS MIL-HDBK-217F
40x90x99 mm (WxHxD)
0.3kg; 27pcs / 9.3kg
I/P: 3 poles, O/P: 6 poles screw DIN terminal
Free air convection
All parameters NOT specially mentioned are measured at 230V AC input, rated load and 25˚C of ambient temperature.
26
For the latest on Altech Power Supplies please visit www.altechcorp.com/power.
PowerSupplies_2013.QXD_PowerSupplies(v5).QXD 9/18/13 5:03 PM Page 27
PSC-60 Series
Type
Approved
E361935
E205412
ENERGY
SAVER
Mechanical Specification
Unit : mm / inch
40
99
Terminal Pin. No Assign. (TB1)
Assignment
FG
AC/N
AC/L
90
Pin No.
1
2
3
Terminal Pin. No Assign. (TB2)
Pin No.
1,2
3,4
5,6
Assignment
DC OUTPUT +V
DC OUTPUT -V
DC OK RELAY CONTACT
N
L
Block Diagram
DC O K
R E C T IF IE R S
&
F I LT E R
E MI
F I LT E R
I /P
R E C T IF IE R S
&
F I LT E R
P OWE R
S W IT C H IN G
+V
-V
DC O K
O .C .P .
D E T E C T IO N
C IR C U IT
O .L .P .
C O NT R O L
O .V .P .
DC OK Relay Contact
Contact Close
When the output voltage reaches the adjusted output voltage
Contact Open
When the output voltage drop below 90% rated output voltage
Contact Ratings (max.)
30V / 1A resistive load
Derating Curve
Load V .S Temp.
Load V .S I/P V oltage
Ta=25°C
100
100
90
Load (%)
Load (%)
80
60
80
70
60
40
50
20
-20
40
0
10
20
30
40
50
Ambient Temperature (°C)
60
70
85
100
110
120
264 VAC
Input Voltage(VAC)60Hz
Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490
27
PowerSupplies_2013.QXD_PowerSupplies(v5).QXD 9/18/13 5:03 PM Page 28
PSC-96 Series
Type
Approved
OUTPUT
E361935
E205412
Features:
•
•
•
•
•
•
•
•
•
•
•
•
ENERGY
SAVER
Universal AC input (88-264V AC)
Protections: Short Circuit / Overload / Overvoltage
Brown-out protection
Installed on DIN rail TS35 / 7.5 or 15
True DC OK signal output
All wiring 105°C long life electrolytic capacitors
High operation temperature up to 70°C
Withstands 2G vibration test
High efficiency, long life and high reliability
3 year warranty
UL1310 Class 2 Power unit / LPS pass
UL508 (Industrial control equipment) listed
Cat. No.
PSC-9612*
PSC-9615*
PSC-9624
PSC-9648
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
RIPPLE & NOISE (max)
12V
7.5A
0 ~ 7.5A
90W
180mVp-p
15V
6.4A
0 ~ 6.4A
96W
180mVp-p
24V
4A
0 ~ 4A
96W
180mVp-p
48V
2A
0 ~ 2A
96W
250mVp-p
Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1µF & 47µF parallel capacitor
VOLTAGE ADJ. RANGE
VOLTAGE TOLERANCE
10.8 ~ 13.2V
±1.0%
13.5 ~ 16.5V
±1.0%
21.6 ~ 26.4V
±1.0%
43.2 ~ 52.8V
±1.0%
Tolerance: includes set up tolerance, line regulation and load regulation.
INPUT
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
±1.0%
±1.0%
±2.0%
±2.0%
< 800ms, < 40ms / 230VAC at full load
> 32ms / 230VAC; >16ms / 115VAC at full load
±1.0%
±2.0%
±1.0%
±2.0%
88 ~ 264VAC; 124 ~ 370VDC
Derating may apply in low input voltage. Please check the derating curve for more details.
PROTECTION
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
OVER LOAD PROTECTION
47Hz~63Hz
< 0.92 / 230VAC; < 0.98 / 115VAC at full load
87%
87%
1.1 A / 115VAC; 0.55A / 230VAC
COLD START 30A / 115VAC; 60A / 230VAC
<1mA / 230VAC
88%
87%
> 102% rated output power
Protection type: Constant current limiting, recovers automatically after fault condition is removed.
OVER VOLTAGE PROTECTION
115% ~ 150% rated output voltage
Protection type: latch-off mode
OVER TEMPERATURE PROTECTION
90˚C ± 10˚C (RTH2) detect on heat sink of power transistor
Protection type: Shut down overvoltage, re-power on to recover
ENVIRONMENT
SAFETY & EMC
OTHERS
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP. / HUMIDITY
TEMP. COEFFICIENT
VIBRATION
-20 ~ +70˚C (Refer to output load derating curve)
20 ~ 90% RH non-condensing
-40 ~ +85˚C; 10 ~ 95% RH
±0.03% / ˚C (0 ~ 50˚C)
10 ~ 500Hz, 2G 10min. / 1cycle, 60 min. each long X,Y, Z axes
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMI CONDUCTION & RADIATION
HARMONIC CURRENT
EMS IMMUNITY
UL508, TUV EN60950-1:2006+A11, UL1310 NEC class 2 compliant
I/P-O/P: 4242DC I/P-FG: 2121DC 1 minute
I/P-O/P, I/P-FG, O/P-FG: 100M Ohms/500VDC
EN55022:2006 Class B
EN61000-3-2:2006 Class A, EN61000-3-3: 1995+A1: 2001+A2: 2005
EN61204-3:2000, EN55024:1998+A1:2001+A2:2003 light industry level, criteria A
The power supply is considered a component which will installed into a final equipment. The final equipment must be re-confirmed
that is still meets EMC directives.
DC OK Signal
MTBF
DIMENSION
PACKING
CONNECTION
COOLING
Relay contact (24VDC / 1A, 120VAC / 1A)
120.4K Hrs MIL-HDBK-217F
55x90x99 mm (WxHxD)
0.4Kg/24 pcs. / 10.8Kg
l/P 3 poles, 0/P: 6 poles screw DIN terminal
Free air convection
All parameters NOT specially mentioned are measured at 230V AC input, rated load and 25˚C of ambient temperature.
*Not included in UL E361935
28
For the latest on Altech Power Supplies please visit www.altechcorp.com/power.
PowerSupplies_2013.QXD_PowerSupplies(v5).QXD 9/18/13 5:03 PM Page 29
PSC-96 Series
Type
Approved
E361935
E205412
ENERGY
SAVER
Mechanical Specification
Unit : mm / inch
55
99
Terminal Pin. No Assign. (TB1)
Assignment
FG
AC/N
AC/L
90
Pin No.
1
2
3
Terminal Pin. No Assign. (TB2)
Pin No.
1,2
3,4
5,6
Assignment
DC OUTPUT +V
DC OUTPUT -V
DC OK RELAY CONTACT
Block Diagram
DC O K
E M I F I LT E R
&
R E C T IF IE R S
I /P
PFC
C IR C U IT
R E C T IF IE R S
&
F I LT E R
P OWE R
S W IT C H IN G
+V
-V
DC O K
O .C .P .
O .L .P .
O .V .P .
O .L .P .
D E T E C T IO N
C IR C U IT
P W M& P F C C O N T R O L
O .V .P .
O .T .P .
DC OK Relay Contact
Contact Close
When the output voltage reaches the adjusted output voltage
Contact Open
When the output voltage drop below 90% rated output voltage
Contact Ratings (max.)
30V / 1A resistive load
Derating Curve
Load V .S Temp.
Load V .S I/P V oltage
Ta=25°C
100
100
90
Load (%)
Load (%)
80
60
80
70
60
40
50
20
-20
40
0
10
20
30
40
50
Ambient Temperature (°C)
60
70
85
100
110
120
264 VAC
Input Voltage(VAC) 60Hz
Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490
29
PowerSupplies_2013.QXD_PowerSupplies(v5).QXD 9/18/13 5:03 PM Page 30
PSC-151 Series
Type
Approved
OUTPUT
E205412
Features:
ENERGY
SAVER
•
•
•
•
•
•
•
•
•
•
•
Universal AC input (88-264V AC)
Installed on DIN rail TS-35 / 7.5 or 15
Built-in active PFC function, PF > 0.95
150% peak load capability
100% full load burn-in test
Protection: SCP, OLP, OVP, OTP
Two selectable peak load modes
Built-in DC OK Relay contact
Built-in Remote ON / OFF function
3 years warranty
UL 508
Cat. No.
PSC-15124
PSC-15148
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
PEAK CURRENT
PEAK POWER
24V
6.3A
0~6.3A
150W
9.45A
225W (3sec.)
48V
3.2A
0~3.2A
150W
4.8A
3 seconds or 20% duty cycle max. and the average output power should not exceed the rate power.
RIPPLE & NOISE (max)
240mVp-p
480mVp-p
Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1µF & 47µF parallel capacitor.
VOLTAGE ADJ. RANGE
VOLTAGE TOLERANCE
-2% ~ +8%
±1.0%
-2% ~ +8%
±1.0%
Tolerance: includes set up tolerance, line regulation and load regulation.
INPUT
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
±0.5%
±1.0%
700ms, 30ms / 230VAC / 115VAC at full load
16ms / 230VAC; 16ms / 115VAC at full load
±0.5%
±1.0%
88 ~ 264VAC; 124 ~ 373VDC
Derating may apply in low input voltage. Please check the derating curve for more details.
PROTECTION
FREQUENCY RANGE
POWER FACTOR(Typ.)
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
47 ~ 63Hz
0.9 / 230VAC; 0.98 / 115VAC at full load
87%
2.6A / 115VAC; 1.3A / 230VAC
33A / 115VAC; 65A / 230VAC
<1mA/ 240VAC
OVERLOAD
Normally works within 105% ~ 150% rated output power for more than 3sec and then shutdown
O/P voltage with outo-recovery, > 150% rated power or short circuit is constant current limiting,
if o/p drop to 40% rating output voltage then shutdown and auto-recover 5 time, if faul condition
not remove in this 5 time, the system well be shutdown and re-power on to recover.
OVER VOLTAGE
29 ~ 33V
87%
56 ~ 65V
Protection type: Latch-off mode, repower on to recover.
OVER TEMPERATURE
ENVIRONMENT
95 ±5°C (TSW: detect on heatsink of power diode)
Protection type: Shut down o/p voltage, recovers automatically after temperature goes down
WORKING TEMP.
-10 ~ +70°C (Refer to derating curve)
Installation clearance: 40mm from top, 20mm from bottom, 5mm from the left and right side are recommended when loaded
permanently with full power. In case the adjacent device is a heat source, 15mm clearance is recommended.
SAFETY & EMC
OTHERS
WORKING HUMIDITY
STORAGE TEMP. / HUMIDITY
TEMP. COEFFICIENT
VIBRATION
20 ~ 95% RH non-condensing
-40 ~ +85°C, 10 ~ 95% RH
±0.03% / °C (0 ~ 50°C)
10 ~ 500Hz, 2G 10min. / 1cycle, 60min. each along X, Y, Z axes
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMI CONDUCTION & RADIATION
HARMONIC CURRENT
EMS IMMUNITY
UL 508 / TUV EN 60950-1
I/P-O/P: 4242VDC, I/P-FG: 2121VDC, O/P-FG: 707VDC, O/P-DC OK: 707VDC
I/P-O/P, I/P-FG, O/P-FG: >100M Ohms / 500VDC / 25°C / 70% RH
EN55022 (CISPR22) Class B
EN61000-3-2, -3
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204; EN55024; EN61000-6-2; (EN50082-2);
EN61204-3; heavy industry level; criteria A, MEET SEMI F47
The power supply is considered a component which will installed into a final equipment. The final equipment must be
re-confirmed that is still meets EMC directives.
DC OK RELAY. CONTACT RATINGS (max)
MTBF
DIMENSION
PACKING
COOLING
60VDC / 0.3A, 30VDC / 1A, 30VAC / 0.5A resistive load
62.7K HRS (MIL-HDBK-217F)
55.5x125.2x99.8 mm (WxHxD)
0.9kg; 12pcs / 12.8kg
Free air convection
All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature.
30
For the latest on Altech Power Supplies please visit www.altechcorp.com/power.
PowerSupplies_2013.QXD_PowerSupplies(v5).QXD 9/18/13 5:03 PM Page 31
PSC-151 Series
Type
Approved
E205412
ENERGY
SAVER
Mechanical Drawings
Unit : mm / inch
Terminal Pin No. Assignment (TB1)
Assignment
Pin NO.
1
2
3
FG
AC/L
AC/N
Terminal Pin No. Assignment (TB2)
55.5
Assignment
Pin NO.
1
2
3
4
5,6
DC+
DCINH+
INHRelay Contact
99.8
123456
TB2
Relay Contact
+
+V
ADJ.
Switch No. Assignment
ON
Assignment
SW NO.
SW1
SW2
OFF
SW1
SW2
PEAK LOAD SETTING
REMOTE ON/OFF SETTING
125.2
DC ON
1 2 3
TB1
Block Diagram
I/P
EMI FIL TER
&
RECTIFIERS
PFC
CIRCUIT
POWER
SWITCHING
RECTIFIERS
&
FIL TER
+V
-V
O.C.P .
FG
O.L.P .
O.L.P .
O.L.P .
DETECTION
CIRCUIT
AC
DETECTION
CIRCUIT
PWM & PFC CONTROL
MICRO
CIRCUIT
O.V .P.
O.T .P.
REMOTE
CONTROL
R e la y C
INH+
INH-
PEAK LOAD
CONTROL
DC OK Relay Contact
Contact Close
Contact Open
Contact Ratings(max.)
When the output voltage reaches the adjusted output voltage.
When the output voltage drop below 45% rated output voltage.
30V/1A resistive load
Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490
31
PowerSupplies_2013.QXD_PowerSupplies(v5).QXD 9/18/13 5:03 PM Page 32
PSC-151 Series
E205412
Type
Approved
ENERGY
SAVER
Peak Load SW1 ON (Mode1) Default setting
I
T-peak
I-peak
T-peak presents while the unit is working within 110%~150%
Rating output power. See curve " B " for the variation in
T-peak between output current and holdup time. If T-peak is
more than the time setting in curve "B", the output current will
drop to the constant current limit (I-normal) that is 105% rating
power, meanwhile, I- normal and T-normal will be presenting.
See curve "A" for the timing back to I-Peak of T-normal and
this Mode can use for easy 2-stage battery charger.
I-normal
T-normal
0
T
Peak Load SW2 OFF (Mode2)
I
T-peak
I-peak
T-peak presents while the unit is working within 110%~150%
Rating output power. See curve " B " for the variation in
T-peak between output current and holdup time. If T-peak is
more than the time setting in curve "B", the output current will
be shut down for 3~4 sec, then auto-recovery.
0
3 ~ 4 sec
T- n ormal (Sec.)
T- peak
24
22
20
18
16
14
12
10
8
6
4
2
0
22
20
18
16
14
12
10
8
6
4
2
0
10 % 20 % 30 % 40 % 50 % 60 % 70 % 80 % 90 %
Load (%)
CURVE A
32
T
I- normal
(Sec.)
110% 115% 120% 125% 130% 135% 140% 145% 150% I- peak
Load (%)
CURVE B
For the latest on Altech Power Supplies please visit www.altechcorp.com/power.
PowerSupplies_2013.QXD_PowerSupplies(v5).QXD 9/18/13 5:03 PM Page 33
PSC-151 Series
E205412
ENERGY
SAVER
Remote ON/OFF
External Power Source
I = 6 ~ 20mA
SW
123456
T he P S U c a n be turne d O N /O F F by us ing the
"R e mote C ontrol" func tion.
SW2
INH+(3 PIN)/ INH-(4 PIN)
Output Status
OFF
SW ON (>2.5V)
ENABLE
OFF
SW OFF (<0.8V)
DISABLE
ON
SW ON (>2.5V)
DISABLE
DISABLE
ON
SW OFF (<0.8V)
ENABLE
TB2
Relay Contact
+
+V
ADJ.
(De fault S etting)
DC ON
ON
OFF
SW1
SW2
Derating Curve
150
Load (%)
112.5
For typ. 3sec
100
60
Continuous
40
-10
0
10
20
30
40
50
60
70
(V ertical)
Ambient Temperature (°C) AC=230 / 1 15V AC
Output derating VS input coltage
100
90
Load (%)
Type
Approved
80
70
60
50
40
88
100
110
135
230 264VAC
Input Voltage (V) 60Hz Ta=25 °C
Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490
33
PowerSupplies_2013.QXD_PowerSupplies(v5).QXD 9/18/13 5:03 PM Page 34
PSC-241 Series
Type
Approved
OUTPUT
E205412
ENERGY
SAVER
Features:
•
•
•
•
•
•
•
•
•
•
•
•
Universal AC input (88-264V AC)
High efficiency 92% and low power dissipation
Installed on DIN rail TS-35 / 7.5 or 15
Built-in active PFC function, PF > 0.95
150% peak load capability
100% full load burn-in test
Protection: SCP, OLP, OVP, OTP
Two selectable peak load modes
Built-in DC OK Relay contact
Built-in Remote ON / OFF function
3 years warranty
UL 508
Cat. No.
PSC-24124
PSC-24148
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
PEAK CURRENT
PEAK POWER
24V
10A
0~10A
240W
15A
360W (3sec.) Two selectable peak load modes
48V
5A
0~5A
240W
7.5A
3 seconds or 20% duty cycle Max. The average output power should not exceed the rate power.
RIPPLE & NOISE (max)
150mVp-p
300mVp-p
Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1µF & 47µF parallel capacitor.
VOLTAGE ADJ. RANGE
VOLTAGE TOLERANCE
-2% ~ +8%
±1.0%
-2% ~ +8%
±1.0%
Tolerance: includes set up tolerance, line regulation and load regulation.
INPUT
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
±0.5%
±1.0%
700ms, 30ms / 230VAC / 115VAC at full load
20ms / 230VAC; 20ms / 115VAC at full load
±0.5%
±1.0%
88 ~ 264VAC; 124 ~ 373VDC
Derating may apply in low input voltage. Please check the derating curve for more details.
PROTECTION
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
47 ~ 63Hz
0.96 / 230VAC; 0.96 / 115VAC at full load
91%
2.6A / 115VAC; 1.3A / 230VAC
33A / 115VAC; 65A / 230VAC
<1mA/ 240VAC
OVERLOAD
>150% rated power or short circuit is constant current limiting.
if o/p drop to 40% rating output voltage then shutdown and auto-recover 5 time, if fault condition
not remove in this 5 time, the system well be shutdown and re-power on to recover.
OVER VOLTAGE
28 ~ 33V
92%
56 ~ 65V
Protection type: Shut down O/P voltage with auto-recovery
OVER TEMPERATURE
95 ±5°C (TSW: detect on heatsink of power diode)
Protection type: Shut down o/p voltage, recovers automatically after temperature goes down
ENVIRONMENT
WORKING TEMP.
-25 ~ +70˚C (Refer to output load derating curve)
Installation clearances: 40mm on top, 20mm on the bottom, 5mm on the left and right side are recommended when loaded
permanently with full power. In case the adjacent device is a heat source, 15mm clearance is recommended.
SAFETY & EMC
WORKING HUMIDITY
STORAGE TEMP. / HUMIDITY
TEMP. COEFFICIENT
VIBRATION
20 ~ 95% RH non-condensing
-40 ~ +85˚C; 10 ~ 95% RH
±0.03% ˚C (0 ~ 50˚C)
10 ~ 500Hz, 2G 10min. / 1cycle, 60 min. each long X,Y, Z axes
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMI CONDUCTION & RADIATION
HARMONIC CURRENT
EMS IMMUNITY
UL508, TUV EN60950-1
I/P-O/P: 4242VDC I/P-FG2121VDC O/P-F/G: 707VDC O/P-DC OK: 707VDC
I/P-O/P, I/P-FG, O/P-FG: > 100M Ohms / 500VDC / 25°C / 70% RH
EN55022:2006 Class B
EN61000-3-2: 2006 Class A, ENG1000-3-3: 1995+A1: 2001+A2: 2005
EN61204-3: 2000, EN55024: 1998+A1: 2001+A2: 2003 light industry level, criteria A
The power supply is considered a component which will installed into a final equipment. The final equipment must be
re-confirmed that is still meets EMC directives.
OTHERS
DC OK RELAY CONTACT RATINGS (max)
MTBF
DIMENSION
PACKING
COOLING
60VDC / 0.3A, 30VDC / 1A, 30VAC / 0.5A resistive load
57K HRS (MIL-HDBK-217F)
65.8x125.2x117.7 mm (WxHxD)
0.9kg; 12pcs / 12.8kg
Free air convection
All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature.
34
For the latest on Altech Power Supplies please visit www.altechcorp.com/power.
PowerSupplies_2013.QXD_PowerSupplies(v5).QXD 9/18/13 5:03 PM Page 35
PSC-241 Series
Type
Approved
E205412
ENERGY
SAVER
Mechanical Drawings
Unit : mm / inch
Terminal Pin No. Assignment (TB1)
Assignment
Pin NO.
1
2
3
FG
AC/L
AC/N
Terminal Pin No. Assignment (TB2)
Assignment
Pin NO.
1
2
3
4
5,6
DC+
DCINH+
INHRelay Contact
65.8
65.80
117.7
117.7
123456
TB2
Relay Contact
+
+V
ADJ.
Switch No. Assignment
DC ON
ON
SW1
SW2
OFF
125.2
Assignment
SW NO.
SW1
SW2
PEAK LOAD SETTING
REMOTE ON/OFF SETTING
1 2 3
TB1
Block Diagram
I/P
ACTIVE
INRUSH
CURRENT
LIMITING
EMI FIL TER
&
RECTIFIERS
PFC
CIRCUIT
POWER
SWITCHING
RECTIFIERS
&
FIL TER
+V
-V
O.C.P .
FG
O.L.P .
AC
DETECTION
CIRCUIT
O.L.P .
DETECTION
CIRCUIT
PFC
CONTROL
PWM POWER
CONTROL
MICRO
CIRCUIT
O.V .P.
O.T .P.
REMOTE
CONTROL
R e la y C onta c t
INH+
INH-
PEAK LOAD
CONTROL
DC OK Relay Contact
Contact Close
Contact Open
Contact Ratings(max.)
When the output voltage reaches the adjusted output voltage.
When the output voltage drop below 45% rated output voltage.
30V/1A resistive load
Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490
35
PowerSupplies_2013.QXD_PowerSupplies(v5).QXD 9/18/13 5:03 PM Page 36
PSC-241 Series
E205412
Type
Approved
ENERGY
SAVER
Peak Load SW1 ON (Mode1) Default setting
I
T-peak
I-peak
T-peak presents while the unit is working within 110%~150%
Rating output power. See curve " B " for the variation in
T-peak between output current and holdup time. If T-peak is
more than the time setting in curve "B", the output current will
drop to the constant current limit (I-normal) that is 105% rating
power, meanwhile, I- normal and T-normal will be presenting.
See curve "A" for the timing back to I-Peak of T-normal and
this Mode can use for easy 2-stage battery charger.
I-normal
T-normal
0
T
Peak Load SW2 OFF (Mode2)
I
T-peak
I-peak
T-peak presents while the unit is working within 110%~150%
Rating output power. See curve " B " for the variation in
T-peak between output current and holdup time. If T-peak is
more than the time setting in curve "B", the output current will
be shut down for 3~4 sec, then auto-recovery.
0
3 ~ 4 sec
T- n ormal (Sec.)
T- peak
24
22
20
18
16
14
12
10
8
6
4
2
0
22
20
18
16
14
12
10
8
6
4
2
0
10 % 20 % 30 % 40 % 50 % 60 % 70 % 80 % 90 %
Load (%)
CURVE A
36
T
I- normal
(Sec.)
110% 115% 120% 125% 130% 135% 140% 145% 150% I- peak
Load (%)
CURVE B
For the latest on Altech Power Supplies please visit www.altechcorp.com/power.
PowerSupplies_2013.QXD_PowerSupplies(v5).QXD 9/18/13 5:03 PM Page 37
PSC-241 Series
Type
Approved
E205412
ENERGY
SAVER
Remote ON/OFF
SW
External Power Source
I = 6 ~ 20mA
123456
T he P S U c a n be turne d O N /O F F by us ing the
"R e mote C ontrol" func tion.
TB2
SW2
INH+(3 PIN)/ INH-(4 PIN)
Output Status
OFF
SW ON (>2.5V)
ENABLE
OFF
SW OFF (<0.8V)
DISABLE
ON
SW ON (>2.5V)
DISABLE
DISABLE
ON
SW OFF (<0.8V)
ENABLE
DC OK
+
+V
ADJ.
DC ON
(De fault S etting)
ON
SW1
SW2
OFF
Derating Curve
150
Load (%)
112.5
For typ. 3sec
100
60
Continuous
40
-10
0
10
20
30
40
50
60
70
(V ertical)
Ambient Temperature (°C) AC=230 / 1 15V AC
Output derating VS input coltage
100
Load (%)
90
80
70
60
50
40
k
88
100
110
135
230 264VAC
Input Voltage(V)60Hz Ta=25 °C
Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490
37
PowerSupplies_2013.QXD_PowerSupplies(v5).QXD 9/18/13 5:03 PM Page 38
PSC-481 Series
Type
Approved
OUTPUT
E205412
ENERGY
SAVER
Features:
•
•
•
•
•
•
•
•
•
•
Universal AC input (88-264V AC)
Installed on DIN rail TS-35 / 7.5 or 15
Built-in active PFC function, PF > 0.95
150% peak load capability
Protection: SCP, OLP, OVP, OTP
Two selectable peak load modes
Built-in DC OK (Open Collector Signal)
Built-in Remote ON / OFF function
3 years warranty
UL 508
Cat. No.
PSC-48124
PSC-48148
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
PEAK CURRENT
PEAK POWER
24V
20A
0~20A
480W
30A
720W (3sec.) Two selectable peak load modes
48V
10A
0~10A
480W
15A
RIPPLE & NOISE (max)
240mVp-p
3 seconds or 20% duty cycle Max. The average output power should not exceed the rate power.
480mVp-p
Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1µF & 47µF parallel capacitor.
VOLTAGE ADJ. RANGE
VOLTAGE TOLERANCE
-5% ~ +5%
±1.0%
±1.0%
Tolerance: includes set up tolerance, line regulation and load regulation.
INPUT
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
±0.5%
±1.0%
800ms, 100ms / 230VAC / 115VAC at full load
16ms / 230VAC; 16ms / 115VAC at full load
±0.5%
±1.0%
88 ~ 264VAC; 124 ~ 373VDC
Derating may apply in low input voltage. Please check the derating curve for more details.
PROTECTION
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
IMRUSH CURRENT (Typ.)
LEAKAGE CURRENT
47 ~ 63Hz
0.96 / 230VAC / 115VAC at full load
93%
5.0A / 115VAC; 2.5A / 230VAC
33A / 115VAC; 65A / 230VAC
< 1mA/ 240VAC
OVERLOAD
Hiccup mode: when the rated output power is within 105% ~ 150% for more than 3secs.
Constant current limit: > 150% rated power / short circuit
Auto-recovery: If O/P drop to 40% of the rated output voltage, PSU will shut down and auto-recover
5times (If fault condition remains after 5times recovery, PSU will shut down. User must re-power on to recover)
OVER VOLTAGE
29 ~ 33V
94%
56 ~ 65V
Protection type: Latch-off mode.
OVER TEMPERATURE
95 ±5°C (TSW: detect on heatsink of power diode)
Protection type: Shut down o/p voltage, recovers automatically after temperature goes down
ENVIRONMENT
WORKING TEMP.
-20 ~ +70˚C (Refer to output load derating curve)
Installation clearance: 40mm from top, 20mm from the left and right side are recommended when
loaded permanently with full power. In case the adjacent device is a heat sorce, 15mm clearance is recomended.
SAFETY & EMC
WORKING HUMIDITY
STORAGE TEMP. / HUMIDITY
TEMP. COEFFICIENT
VIBRATION
20 ~ 95% RH non-condensing
-40 ~ +85˚C; 10 ~ 95% RH
±0.03% ˚C (0 ~ 50˚C)
10 ~ 500Hz, 2G 10min. / 1cycle, 60 min. each long X,Y, Z axes
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMI CONDUCTION & RADIATION
HARMONIC CURRENT
EMS IMMUNITY
UL 508 / EN 60950-1
I/P-O/P: 4242VDC, I/P-FG: 2121VDC, O/P-FG: 707VDC, O/P-DC OK: 707VDC
I/P-O/P, I/P-FG, O/P-FG: >100M Ohms / 500VDC / 25°C / 70% RH
EN 55022 (CISPR22), EN 61000-6-3
EN61000-3-2, -3-3
IEC 61000-4-2, 3, 4, 5, 6, 8, 11; EN 61000-6-1; EN 61204-3
The power supply is considered a component which will installed into a final equipment. The final equipment must be
re-confirmed that is still meets EMC directives.
OTHERS
DC OK RELAY CONTACT RATINGS (max)
DIMENSION
PACKING
60VDC / 0.3A, 30VDC / 1A, 30VAC / 0.5A resistive load
86.3x124.8x123.4 mm (WxHxD)
1.45kg; 8pcs / 12kg
All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature.
38
For the latest on Altech Power Supplies please visit www.altechcorp.com/power.
PowerSupplies_2013.QXD_PowerSupplies(v5).QXD 9/18/13 5:03 PM Page 39
PSC-481 Series
Type
Approved
E205412
ENERGY
SAVER
Mechanical Drawings
Unit : mm / inch
Terminal Pin No. Assignment (TB1)
Assignment
Pin NO.
1
2
3
FG
AC/L
AC/N
Te rmina l P in N o. A s s ignme nt ( T B 2)
Assignment
Pin NO.
1-3
4-6
7
8
9,10
86.3
DC+
DCINH+
INHDC OK Singal
123.4
1 2 3 4 5 6 7 8 910
TB2
DC OK
+
+V
ADJ.
Switch No. Assignment
DC ON
ON
OFF
124.8
Assignment
SW NO.
SW1
SW2
SW1
SW2
PEAK LOAD SETTING
REMOTE ON/OFF SETTING
1 2 3
TB1
Block Diagram
I/P
ACTIVE
iNRUSH
CURRENT
LIMITING
EMI FIL TER
&
RECTIFIERS
PFC
CIRCUIT
POWER
SWITCHING
RECTIFIERS
&
FIL TER
+V
-V
O.C.P .
FG
O.L.P .
AC
DETECTION
CIRCUIT
O.L.P .
DETECTION
CIRCUIT
PFC
CONTROL
PWM POWER
CONTROL
MICRO
CIRCUIT
O.V .P.
D C O K S inga l
O.T .P.
REMOTE
CONTROL
INH+
INH-
PEAK LOAD
CONTROL
DC OK Relay Contact
Contact Ratings(max.)
Isolation V oltage
CTR : MIN. 50% at IF = 5mA, V CE = 5V
Between input and output V iso = 3750V rms
Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490
39
PowerSupplies_2013.QXD_PowerSupplies(v5).QXD 9/18/13 5:03 PM Page 40
PSC-481 Series
E205412
Type
Approved
ENERGY
SAVER
Peak Load SW1 ON (Mode1) Default setting
I
T-peak
I-peak
T-peak presents while the unit is working within 110%~150%
Rating output power. See curve " B " for the variation in
T-peak between output current and holdup time. If T-peak is
more than the time setting in curve "B", the output current will
drop to the constant current limit (I-normal) that is 105% rating
power, meanwhile, I- normal and T-normal will be presenting.
See curve "A" for the timing back to I-Peak of T-normal and
this Mode can use for easy 2-stage battery charger.
I-normal
T-normal
0
T
Peak Load SW2 OFF (Mode2)
I
T-peak
I-peak
T-peak presents while the unit is working within 110%~150%
Rating output power. See curve " B " for the variation in
T-peak between output current and holdup time. If T-peak is
more than the time setting in curve "B", the output current will
be shut down for 3~4 sec, then auto-recovery.
0
3 ~ 4 sec
T- n ormal (Sec.)
T- peak
24
22
20
18
16
14
12
10
8
6
4
2
0
22
20
18
16
14
12
10
8
6
4
2
0
10 % 20 % 30 % 40 % 50 % 60 % 70 % 80 % 90 %
Load (%)
CURVE A
40
T
I- normal
(Sec.)
110% 115% 120% 125% 130% 135% 140% 145% 150% I- peak
Load (%)
CURVE B
For the latest on Altech Power Supplies please visit www.altechcorp.com/power.
PowerSupplies_2013.QXD_PowerSupplies(v5).QXD 9/18/13 5:03 PM Page 41
PSC-481 Series
Type
Approved
E205412
ENERGY
SAVER
Remote ON/OFF
SW
External Power Source
I = 6 ~ 20mA
123456
T he P S U c a n be turne d O N /O F F by us ing the
"R e mote C ontrol" func tion.
TB2
SW2
INH+(3 PIN)/ INH-(4 PIN)
Output Status
OFF
SW ON (>2.5V)
ENABLE
OFF
SW OFF (<0.8V)
DISABLE
ON
SW ON (>2.5V)
DISABLE
DISABLE
ON
SW OFF (<0.8V)
ENABLE
DC OK
+
+V
ADJ.
DC ON
(De fault S etting)
ON
SW1
SW2
OFF
Derating Curve
150
Load (%)
112.5
For typ. 3sec
100
60
Continuous
40
-10
0
10
20
30
40
50
60
70
(V ertical)
Ambient Temperature (°C) AC=230 / 1 15V AC
Output derating VS input coltage
100
Load (%)
90
80
70
60
50
40
ak
88
100
110
135
230 264VAC
Input Voltage(V)60Hz Ta=25 °C