PowerSupplies_2013.QXD_PowerSupplies(v5).QXD 9/18/13 5:07 PM Page 20 PSC-10 Series Type Approved OUTPUT E361935 E205412 Features: ENERGY SAVER • • • • • • • • • • • • Universal AC input (88-264V AC) Protections: Short Circuit / Overload / Overvoltage Brown-out protection Installed on DIN rail TS35 / 7.5 or 15 True DC OK signal output All wiring 105°C long life electrolytic capacitors High operation temperature up to 70°C Withstands 2G vibration test High efficiency, long life and high reliability 3 year warranty UL1310 Class 2 Power unit / LPS pass UL508 (Industrial control equipment) listed Cat. No. PSC-1012 PSC-1015 PSC-1024 DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER RIPPLE & NOISE (max) 12V 0.84A 0~0.84A 10.08W 100mVp-p 15V 0.67A 0~0.67A 10.05W 100mVp-p 24V 0.42A 0~0.42A 10.08W 120mVp-p Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1µF & 47µF parallel capacitor VOLTAGE ADJ. RANGE VOLTAGE TOLERANCE 10.8-13.2V ±1.0% 13.5-16.5V ±1.0% 21.6-26.4V ±1.0% Tolerance: includes set up tolerance, line regulation and load regulation. INPUT LINE REGULATION LOAD REGULATION SETUP, RISE TIME HOLD UP TIME (Typ.) VOLTAGE RANGE ±1.0% ±1.0% ±1.0% ±1.0% < 800ms, < 100ms/230V AC at full load > 32ms / 230V AC; > 16ms / 115V AC at full load 88V~264VAC; 124V~370VDC ±1.0% ±1.0% Derating may be needed under low input voltages. Please check the derating curve for more details. PROTECTION FREQUENCY RANGE EFFICIENCY (Typ.) AC CURRENT (Typ.) INRUSH CURRENT (Typ.) LEAKAGE CURRENT OVERLOAD PROTECTION 47~63Hz 81% 0.23A/115VAC; 0.17A/230VAC 15A / 115V AC; 30A / 230V AC < 1mA/ 230VAC 81% 81% > 102% rated output power Protection type: Constant current limiting, recovers automatically after fault condition is removed. OVERVOLTAGE PROTECTION 115%-150% rated output voltage Protection type: Latch-off mode. ENVIRONMENT SAFETY & EMC OTHERS OVER TEMPERATURE PROTECTION Power supply shut down at 70˚C constant current limiting / output voltage goes to 0; re-power on to recover WORKING TEMP. WORKING HUMIDITY STORAGE TEMP. / HUMIDITY TEMP. COEFFICIENT VIBRATION -20 ~ +70˚C (Refer to output load derating curve) 20 ~ 90% RH non-condensing -40 ~ +85˚C; 10 ~ 95% RH ±0.03% / ˚C (0 ~ 50˚C) 10 ~ 500Hz, 2G 10min. / 1cycle, 60 min. each long X,Y, Z axes SAFETY STANDARDS WITHSTAND VOLTAGE ISOLATION RESISTANCE EMI CONDUCTION & RADIATION HARMONIC CURRENT EMS IMMUNITY UL508, TUV EN60950-1:2006+A11, UL1310 NEC class 2 compliant I/P-O/P: 3KVAC (4242DC) I/P-FG: 1.5KVAC (2121DC) 1 minute I/P-O/P, I/P-FG, O/P-FG: 100M Ohms/500VDC EN55022:2006+A1:2007 Class B EN61000-3-2:2006 Class A, EN61000-3-3:2008 EN61204-3:2000, EN55024:1998+A1:2001+A2:2003 light industry level, criteria A The power supply is considered a component which will installed into a final equipment. The final equipment must be re-confirmed that is still meets EMC directives. DC OK Signal MTBF DIMENSION PACKING CONNECTION COOLING Open collector. Max: 40mA 562.7K hrs MIL-HDBK-217K 23x90x99 mm (WxHxD) 0.13Kg/48 pcs./7.44Kg I/P 3 poles, O/P: 3 poles screw DIN terminal Free air convection All parameters NOT specially mentioned are measured at 230V AC input, rated load and 25˚C of ambient temperature. 20 For the latest on Altech Power Supplies please visit www.altechcorp.com/power. PowerSupplies_2013.QXD_PowerSupplies(v5).QXD 9/18/13 5:03 PM Page 21 PSC-10 Series Type Approved E361935 E205412 ENERGY SAVER Mechanical Specification Unit : mm / inch 23 99 Terminal Pin. No Assign. (TB1) 90 Assignment FG AC/N AC/L Pin No. 1 2 3 Terminal Pin. No Assign. (TB2) Pin No. Assignment 4 DC OUTPUT +V DC OUTPUT -V 5 DC OK SIGNAL 6 5 5 Application of DC OK Active Signal (a)5V s ignal (b)LE D DC OK (c)R elay DC OK Mode l R 5.1V V- R 12V >1.5KΩ 15V >2KΩ 24V >3.9KΩ DC OK R V- Mode l R 12V >2.4KΩ 15V >3KΩ 24V >4.7KΩ R e la y RL V- Mode l R 12V >700Ω 15V >700Ω 24V >1.2KΩ Block Diagram DC O K DC O K R E C T IF IE R S & F I LT E R E MI F I LT E R I /P R E C T IF IE R S & F I LT E R P OWE R S W IT C H IN G +V -V O.C .P D E T E C T IO N C IR C U IT O .L .P . C O NT R O L O .V .P . Derating Curve Load V .S Temp. Load V .S I/P V oltage Ta=25°C 100 100 90 Load (%) Load (%) 80 60 80 70 60 40 50 20 -20 40 0 10 20 30 40 50 Ambient Temperature (°C) 60 70 85 100 110 120 264 VAC Input Voltage(VAC) 60Hz Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 21 PowerSupplies_2013.QXD_PowerSupplies(v5).QXD 9/18/13 5:03 PM Page 22 PSC-20 Series Type Approved OUTPUT E361935 E205412 Features: ENERGY SAVER • • • • • • • • • • • • Universal AC input (88-264V AC) Protections: Short Circuit / Overload / Overvoltage Brown-out protection Installed on DIN rail TS35 / 7.5 or 15 True DC OK signal output All wiring 105°C long life electrolytic capacitors High operation temperature up to 70°C Withstands 2G vibration test High efficiency, long life and high reliability 3 year warranty UL1310 Class 2 Power unit / LPS pass UL508 (Industrial control equipment) listed Cat. No. PSC-2012 PSC-2015 PSC-2024 DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER RIPPLE & NOISE (max) 12V 1.7A 0~1.7A 20.4W 100mVp-p 15V 1.4A 0~1.4A 21W 100mVp-p 24V 1A 0~1A 24W 120mVp-p Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1µF & 47µF parallel capacitor VOLTAGE ADJ. RANGE VOLTAGE TOLERANCE 10.8-13.2V ±1.0% 13.5-16.5V ±1.0% 21.6-26.4V ±1.0% Tolerance: includes set up tolerance, line regulation and load regulation. INPUT LINE REGULATION LOAD REGULATION SETUP, RISE TIME HOLD UP TIME (Typ.) VOLTAGE RANGE ±1.0% ±1.0% ±1.0% ±1.0% < 800ms, < 100ms/230V AC at full load > 32ms / 230V AC; > 16ms / 115V AC at full load 88V~264VAC; 124V~370VDC ±1.0% ±1.0% Derating may be needed under low input voltages. Please check the derating curve for more details. PROTECTION FREQUENCY RANGE EFFICIENCY (Typ.) AC CURRENT (Typ.) INRUSH CURRENT (Typ.) LEAKAGE CURRENT OVERLOAD PROTECTION 47~63Hz 83% 0.45A/115VAC; 0.32A/230VAC 20A / 115V AC; 40A / 230V AC < 1mA/ 230VAC 85% 86% > 105% rated output power Protection type: Constant current limiting, recovers automatically after fault condition is removed. OVERVOLTAGE PROTECTION 115%-150% rated output voltage Protection type: Latch-off mode. ENVIRONMENT SAFETY & EMC OTHERS OVER TEMPERATURE PROTECTION Power supply shut down at 70˚C constant current limiting / output voltage goes to 0; re-power on to recover WORKING TEMP. WORKING HUMIDITY STORAGE TEMP. / HUMIDITY TEMP. COEFFICIENT VIBRATION -20 ~ +70˚C (Refer to output load derating curve) 20 ~ 90% RH non-condensing -40 ~ +85˚C; 10 ~ 95% RH ±0.03% / ˚C (0 ~ 50˚C) 10 ~ 500Hz, 2G 10min. / 1cycle, 60 min. each long X,Y, Z axes SAFETY STANDARDS WITHSTAND VOLTAGE ISOLATION RESISTANCE EMI CONDUCTION & RADIATION HARMONIC CURRENT EMS IMMUNITY UL508, TUV EN60950-1:2006+A11, UL1310 NEC class 2 compliant I/P-O/P: 4242DC I/P-FG: 2121DC 1 minute I/P-O/P, I/P-FG, O/P-FG: 100M Ohms/500VDC EN55022:2006+A1:2007 Class B EN61000-3-2:2006 Class A, EN61000-3-3:2008 EN61204-3:2000, EN55024:1998+A1:2001+A2:2003 light industry level, criteria A The power supply is considered a component which will installed into a final equipment. The final equipment must be re-confirmed that is still meets EMC directives. DC OK Signal MTBF DIMENSION PACKING CONNECTION COOLING Open collector. Max: 40mA 120.4K HRS MIL-HDBK-217 (25˚C) 131.3K HRS MIL-HDBK-217 (25˚C) 23x90x99 mm (WxHxD) 0.14Kg/48 pcs./7.92Kg I/P 3 poles, O/P: 3 poles screw DIN terminal Free air convection 125.9K HRS MIL-HDBK-217 (25˚C) All parameters NOT specially mentioned are measured at 230V AC input, rated load and 25˚C of ambient temperature. 22 For the latest on Altech Power Supplies please visit www.altechcorp.com/power. PowerSupplies_2013.QXD_PowerSupplies(v5).QXD 9/18/13 5:03 PM Page 23 PSC-20 Series Type Approved E361935 E205412 ENERGY SAVER Mechanical Specification Unit : mm / inch 23 99 Terminal Pin. No Assign. (TB1) Pin No. 1 2 3 90 Assignment FG AC/N AC/L Terminal Pin. No Assign. (TB2) Pin No. Assignment DC OUTPUT +V 4 DC OUTPUT -V 5 DC OK SIGNAL 6 5 5 Application of DC OK Active Signal (a)5V s ignal (b)LE D DC OK (c)R elay DC OK Mode l R 12V 5.1V V- R DC OK R ≥1 . 5 K Ω Mode l 12V Mode l R ≥2 . 4 K Ω 15V ≥2 K Ω 15V ≥3 K Ω 24V ≥3 . 9 K Ω 24V ≥4 . 7 K Ω V- R e la y 12V RL V- R ≥7 0 0 Ω 15V ≥7 0 0 Ω 24V ≥1 . 2 K Ω Block Diagram DC O K DC O K R E C T IF IE R S & F I LT E R E MI F I LT E R I /P R E C T IF IE R S & F I LT E R P OWE R S W IT C H IN G +V -V O.C .P D E T E C T IO N C IR C U IT O .L .P . C O NT R O L O .V .P . Derating Curve Load V .S Temp. Load V .S I/P V oltage Ta=25°C 100 100 90 Load (%) Load (%) 80 60 80 70 60 40 50 20 -20 40 0 10 20 30 40 50 Ambient Temperature (°C) 60 70 85 100 110 120 264 VAC Input Voltage(VAC)60Hz Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 23 PowerSupplies_2013.QXD_PowerSupplies(v5).QXD 9/18/13 5:03 PM Page 24 PSC-40 Series Type Approved OUTPUT E361935 E205412 Features: • • • • • • • • • • • • ENERGY SAVER Universal AC input (88-264V AC) Protections: Short Circuit / Overload / Overvoltage Brown-out protection Installed on DIN rail TS35 / 7.5 or 15 True DC OK signal output All wiring 105°C long life electrolytic capacitors High operation temperature up to 70°C Withstands 2G vibration test High efficiency, long life and high reliability 3 year warranty UL1310 Class 2 Power unit / LPS pass UL508 (Industrial control equipment) listed Cat. No. PSC-4012 PSC-4015 PSC-4024 PSC-4048 DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER RIPPLE & NOISE (max) 12V 3.4A 0 ~ 3.4A 40.8W 100mVp-p 15V 2.7A 0 ~ 2.7A 40.5W 100mVp-p 24V 1.7A 0 ~ 1.7A 40.8W 120mVp-p 48V 0.85A 0 ~ 0.85A 40.8W 180mVp-p Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1µF & 47µF parallel capacitor VOLTAGE ADJ. RANGE VOLTAGE TOLERANCE 10.8 ~ 13.2V ±1.0% 13.5 ~ 16.5V ±1.0% 21.6 ~ 26.4V ±1.0% 43.2 ~ 52.8V ±1.0% Tolerance: includes set up tolerance, line regulation and load regulation. INPUT LINE REGULATION LOAD REGULATION SETUP, RISE TIME HOLD UP TIME (Typ.) VOLTAGE RANGE ±1.0% ±1.0% ±1.0% ±1.0% < 800ms, < 50ms / 230VAC at full load > 32ms / 230VAC; >16ms / 115VAC at full load 88 ~ 264VAC; 124 ~ 370VDC ±1.0% ±1.0% ±1.0% ±1.0% Derating may be needed under low input voltages. Please check the derating curve for more details. FREQUENCY RANGE EFFICIENCY (Typ.) AC CURRENT (Typ.) INRUSH CURRENT (Typ.) LEAKAGE CURRENT PROTECTION OVERLOAD PROTECTION 47~63Hz 84% 84% 0.8 A / 115VAC; 0.4A / 230VAC COLD START 30A / 115VAC; 60A / 230VAC < 1mA/ 230VAC 84% 85% > 105% rated output power Protection type: Constant current limiting, recovers automatically after fault condition is removed. OVERVOLTAGE PROTECTION 115% ~ 150% rated output voltage Protection type: latch-off mode ENVIRONMENT SAFETY & EMC OTHERS OVER TEMPERATURE PROTECTION Power supply shut down at 70˚C constant current limiting / output voltage goes to 0; re-power on to recover WORKING TEMP. WORKING HUMIDITY STORAGE TEMP. / HUMIDITY TEMP. COEFFICIENT VIBRATION -20 ~ +70˚C (Refer to output load derating curve) 20 ~ 90% RH non-condensing -40 ~ +85˚C; 10 ~ 95% RH ±0.03% / ˚C (0 ~ 50˚C) 10 ~ 500Hz, 2G 10min. / 1cycle, 60 min. each long X,Y, Z axes SAFETY STANDARDS WITHSTAND VOLTAGE ISOLATION RESISTANCE EMI CONDUCTION & RADIATION HARMONIC CURRENT EMS IMMUNITY UL508, TUV EN60950-1:2006+A11, UL1310 NEC class 2 compliant I/P-O/P: 4242DC I/P-FG: 2121DC 1 minute I/P-O/P, I/P-FG, O/P-FG: 100M Ohms/500VDC EN55022: 2006 Class B EN61000-3-2: 2006 Class A, EN61000-3-3: 1995+A1: 2001+A2: 2005 EN61204-3:2000, EN55024:1998+A1:2001+A2:2003 light industry level, criteria A The power supply is considered a component which will installed into a final equipment. The final equipment must be re-confirmed that is still meets EMC directives. DC OK Signal MTBF DIMENSION PACKING CONNECTION COOLING Relay contact (30VDC / 1A, 120VAC / 1A) 947.2K hrs MIL-HDBK-217K 40x90x99 mm (WxHxD) 0.28Kg/27 pcs./8.76Kg I/P 3 poles, O/P: 6 poles screw DIN terminal Free air convection All parameters NOT specially mentioned are measured at 230V AC input, rated load and 25˚C of ambient temperature. 24 For the latest on Altech Power Supplies please visit www.altechcorp.com/power. PowerSupplies_2013.QXD_PowerSupplies(v5).QXD 9/18/13 5:03 PM Page 25 PSC-40 Series Type Approved E361935 E205412 ENERGY SAVER Mechanical Specification Unit : mm / inch 40 99 Terminal Pin. No Assign. (TB1) Assignment FG AC/N AC/L 90 Pin No. 1 2 3 Terminal Pin. No Assign. (TB2) Pin No. 1,2 3,4 5,6 Assignment DC OUTPUT +V DC OUTPUT -V DC OK RELAY CONTACT N L Block Diagram DC O K R E C T IF IE R S & F I LT E R E MI F I LT E R I /P R E C T IF IE R S & F I LT E R P OWE R S W IT C H IN G +V -V O .C .P . DC O K D E T E C T IO N C IR C U IT O .L .P . C O NT R O L O .V .P . DC OK Relay Contact Contact Close When the output voltage reaches the adjusted output voltage Contact Open When the output voltage drop below 90% rated output voltage Contact Ratings (max.) 30V / 1A resistive load Derating Curve Load V .S Temp. Load V .S I/P V oltage Ta=25°C 100 100 90 Load (%) Load (%) 80 60 80 70 60 40 50 20 -20 40 0 10 20 30 40 50 Ambient Temperature (°C) 60 70 85 100 110 120 264 VAC Input Voltage(VAC)60Hz Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 25 PowerSupplies_2013.QXD_PowerSupplies(v5).QXD 9/18/13 5:03 PM Page 26 PSC-60 Series Type Approved OUTPUT E361935 E205412 Features: • • • • • • • • • • • • ENERGY SAVER Universal AC input (88-264V AC) Protections: Short Circuit / Overload / Overvoltage Brown-out protection Installed on DIN rail TS35 / 7.5 or 15 True DC OK signal output All wiring 105°C long life electrolytic capacitors High operation temperature up to 70°C Withstands 2G vibration test High efficiency, long life and high reliability 3 year warranty UL1310 Class 2 Power unit / LPS pass UL508 (Industrial control equipment) listed Cat. No. PSC-6012 PSC-6015 PSC-6024 PSC-6048 DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER RIPPLE & NOISE (max) 12V 5A 0 ~ 5A 60W 100mVp-p 15V 4A 0 ~ 4A 60W 100mVp-p 24V 2.5A 0 ~ 2.5A 60W 120mVp-p 48V 1.25A 0 ~ 1.25A 60W 180mVp-p Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1µF & 47µF parallel capacitor VOLTAGE ADJ. RANGE VOLTAGE TOLERANCE 10.8 ~ 13.2V ±1.0% 13.5 ~ 16.5V ±1.0% 21.6 ~ 26.4V ±1.0% 43.2 ~ 52.8V ±1.0% Tolerance: includes set up tolerance, line regulation and load regulation. LINE REGULATION LOAD REGULATION SETUP, RISE TIME ±1.0% ±1.0% ±1.0% ±1.0% < 800ms, < 50ms / 230VAC at full load ±1.0% ±1.0% ±1.0% ±1.0% Length of set up time is measured at sold first start. Turning ON/OFF the power supply may lead to increase of the set up time. INPUT HOLD UP TIME (Typ.) VOLTAGE RANGE > 32ms / 230VAC; >16ms / 115VAC at full load 88 ~ 264VAC; 124 ~ 370VDC Derating may apply in low input voltage. Please check the derating curve for more details. PROTECTION FREQUENCY RANGE EFFICIENCY (Typ.) AC CURRENT (Typ.) INRUSH CURRENT (Typ.) LEAKAGE CURRENT OVER LOAD PROTECTION 47~63Hz 86% 87% 1.3 A / 115VAC; 0.6A / 230VAC COLD START 30A / 115VAC; 60A / 230VAC <1mA / 230VAC 87% 88% > 102% rated output power Protection type: Constant current limiting, recovers automatically after fault condition is removed OVER VOLTAGE PROTECTION 115% ~ 150% rated output voltage Protection type: latch-off mode ENVIRONMENT SAFETY & EMC OTHERS OVER TEMPERATURE PROTECTION Power supply shut down at 70˚C constant current limiting / output voltage goes to 0; re-power on to recover WORKING TEMP. WORKING HUMIDITY STORAGE TEMP. / HUMIDITY TEMP. COEFFICIENT VIBRATION -20 ~ +70˚C (Refer to output load derating curve) 20 ~ 90% RH non-condensing -40 ~ +85˚C; 10 ~ 95% RH ±0.03% / ˚C (0 ~ 50˚C) 10 ~ 500Hz, 2G 10min. / 1cycle, 60 min. each long X,Y, Z axes SAFETY STANDARDS WITHSTAND VOLTAGE ISOLATION RESISTANCE EMI CONDUCTION & RADIATION HARMONIC CURRENT EMS IMMUNITY UL508, TUV EN60950-1:2006+A11, UL1310 NEC class 2 compliant I/P-O/P: 4242DC, I/P-FG: 2121DC 1minute I/P-O/P, I/P-FG, O/P-FG: 100M Ohms/500VDC EN55022: 2006 Class B EN61000-3-2: 2006 Class A, EN61000-3-3: 1995+A1: 2001+A2: 2005 EN61204-3: 2000, EN55024: 1998+A1:2001+A2: 2003 light industry level, criteria A The power supply is considered a component which will installed into a final equipment. The final equipment must be re-confirmed that is still meets EMC directives. DC OK Signal MTBF DIMENSION PACKING CONNECTION COOLING Relay contact (24VDC / 1A, 120VAC / 1A) 944.6K HRS MIL-HDBK-217F 40x90x99 mm (WxHxD) 0.3kg; 27pcs / 9.3kg I/P: 3 poles, O/P: 6 poles screw DIN terminal Free air convection All parameters NOT specially mentioned are measured at 230V AC input, rated load and 25˚C of ambient temperature. 26 For the latest on Altech Power Supplies please visit www.altechcorp.com/power. PowerSupplies_2013.QXD_PowerSupplies(v5).QXD 9/18/13 5:03 PM Page 27 PSC-60 Series Type Approved E361935 E205412 ENERGY SAVER Mechanical Specification Unit : mm / inch 40 99 Terminal Pin. No Assign. (TB1) Assignment FG AC/N AC/L 90 Pin No. 1 2 3 Terminal Pin. No Assign. (TB2) Pin No. 1,2 3,4 5,6 Assignment DC OUTPUT +V DC OUTPUT -V DC OK RELAY CONTACT N L Block Diagram DC O K R E C T IF IE R S & F I LT E R E MI F I LT E R I /P R E C T IF IE R S & F I LT E R P OWE R S W IT C H IN G +V -V DC O K O .C .P . D E T E C T IO N C IR C U IT O .L .P . C O NT R O L O .V .P . DC OK Relay Contact Contact Close When the output voltage reaches the adjusted output voltage Contact Open When the output voltage drop below 90% rated output voltage Contact Ratings (max.) 30V / 1A resistive load Derating Curve Load V .S Temp. Load V .S I/P V oltage Ta=25°C 100 100 90 Load (%) Load (%) 80 60 80 70 60 40 50 20 -20 40 0 10 20 30 40 50 Ambient Temperature (°C) 60 70 85 100 110 120 264 VAC Input Voltage(VAC)60Hz Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 27 PowerSupplies_2013.QXD_PowerSupplies(v5).QXD 9/18/13 5:03 PM Page 28 PSC-96 Series Type Approved OUTPUT E361935 E205412 Features: • • • • • • • • • • • • ENERGY SAVER Universal AC input (88-264V AC) Protections: Short Circuit / Overload / Overvoltage Brown-out protection Installed on DIN rail TS35 / 7.5 or 15 True DC OK signal output All wiring 105°C long life electrolytic capacitors High operation temperature up to 70°C Withstands 2G vibration test High efficiency, long life and high reliability 3 year warranty UL1310 Class 2 Power unit / LPS pass UL508 (Industrial control equipment) listed Cat. No. PSC-9612* PSC-9615* PSC-9624 PSC-9648 DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER RIPPLE & NOISE (max) 12V 7.5A 0 ~ 7.5A 90W 180mVp-p 15V 6.4A 0 ~ 6.4A 96W 180mVp-p 24V 4A 0 ~ 4A 96W 180mVp-p 48V 2A 0 ~ 2A 96W 250mVp-p Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1µF & 47µF parallel capacitor VOLTAGE ADJ. RANGE VOLTAGE TOLERANCE 10.8 ~ 13.2V ±1.0% 13.5 ~ 16.5V ±1.0% 21.6 ~ 26.4V ±1.0% 43.2 ~ 52.8V ±1.0% Tolerance: includes set up tolerance, line regulation and load regulation. INPUT LINE REGULATION LOAD REGULATION SETUP, RISE TIME HOLD UP TIME (Typ.) VOLTAGE RANGE ±1.0% ±1.0% ±2.0% ±2.0% < 800ms, < 40ms / 230VAC at full load > 32ms / 230VAC; >16ms / 115VAC at full load ±1.0% ±2.0% ±1.0% ±2.0% 88 ~ 264VAC; 124 ~ 370VDC Derating may apply in low input voltage. Please check the derating curve for more details. PROTECTION FREQUENCY RANGE POWER FACTOR (Typ.) EFFICIENCY (Typ.) AC CURRENT (Typ.) INRUSH CURRENT (Typ.) LEAKAGE CURRENT OVER LOAD PROTECTION 47Hz~63Hz < 0.92 / 230VAC; < 0.98 / 115VAC at full load 87% 87% 1.1 A / 115VAC; 0.55A / 230VAC COLD START 30A / 115VAC; 60A / 230VAC <1mA / 230VAC 88% 87% > 102% rated output power Protection type: Constant current limiting, recovers automatically after fault condition is removed. OVER VOLTAGE PROTECTION 115% ~ 150% rated output voltage Protection type: latch-off mode OVER TEMPERATURE PROTECTION 90˚C ± 10˚C (RTH2) detect on heat sink of power transistor Protection type: Shut down overvoltage, re-power on to recover ENVIRONMENT SAFETY & EMC OTHERS WORKING TEMP. WORKING HUMIDITY STORAGE TEMP. / HUMIDITY TEMP. COEFFICIENT VIBRATION -20 ~ +70˚C (Refer to output load derating curve) 20 ~ 90% RH non-condensing -40 ~ +85˚C; 10 ~ 95% RH ±0.03% / ˚C (0 ~ 50˚C) 10 ~ 500Hz, 2G 10min. / 1cycle, 60 min. each long X,Y, Z axes SAFETY STANDARDS WITHSTAND VOLTAGE ISOLATION RESISTANCE EMI CONDUCTION & RADIATION HARMONIC CURRENT EMS IMMUNITY UL508, TUV EN60950-1:2006+A11, UL1310 NEC class 2 compliant I/P-O/P: 4242DC I/P-FG: 2121DC 1 minute I/P-O/P, I/P-FG, O/P-FG: 100M Ohms/500VDC EN55022:2006 Class B EN61000-3-2:2006 Class A, EN61000-3-3: 1995+A1: 2001+A2: 2005 EN61204-3:2000, EN55024:1998+A1:2001+A2:2003 light industry level, criteria A The power supply is considered a component which will installed into a final equipment. The final equipment must be re-confirmed that is still meets EMC directives. DC OK Signal MTBF DIMENSION PACKING CONNECTION COOLING Relay contact (24VDC / 1A, 120VAC / 1A) 120.4K Hrs MIL-HDBK-217F 55x90x99 mm (WxHxD) 0.4Kg/24 pcs. / 10.8Kg l/P 3 poles, 0/P: 6 poles screw DIN terminal Free air convection All parameters NOT specially mentioned are measured at 230V AC input, rated load and 25˚C of ambient temperature. *Not included in UL E361935 28 For the latest on Altech Power Supplies please visit www.altechcorp.com/power. PowerSupplies_2013.QXD_PowerSupplies(v5).QXD 9/18/13 5:03 PM Page 29 PSC-96 Series Type Approved E361935 E205412 ENERGY SAVER Mechanical Specification Unit : mm / inch 55 99 Terminal Pin. No Assign. (TB1) Assignment FG AC/N AC/L 90 Pin No. 1 2 3 Terminal Pin. No Assign. (TB2) Pin No. 1,2 3,4 5,6 Assignment DC OUTPUT +V DC OUTPUT -V DC OK RELAY CONTACT Block Diagram DC O K E M I F I LT E R & R E C T IF IE R S I /P PFC C IR C U IT R E C T IF IE R S & F I LT E R P OWE R S W IT C H IN G +V -V DC O K O .C .P . O .L .P . O .V .P . O .L .P . D E T E C T IO N C IR C U IT P W M& P F C C O N T R O L O .V .P . O .T .P . DC OK Relay Contact Contact Close When the output voltage reaches the adjusted output voltage Contact Open When the output voltage drop below 90% rated output voltage Contact Ratings (max.) 30V / 1A resistive load Derating Curve Load V .S Temp. Load V .S I/P V oltage Ta=25°C 100 100 90 Load (%) Load (%) 80 60 80 70 60 40 50 20 -20 40 0 10 20 30 40 50 Ambient Temperature (°C) 60 70 85 100 110 120 264 VAC Input Voltage(VAC) 60Hz Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 29 PowerSupplies_2013.QXD_PowerSupplies(v5).QXD 9/18/13 5:03 PM Page 30 PSC-151 Series Type Approved OUTPUT E205412 Features: ENERGY SAVER • • • • • • • • • • • Universal AC input (88-264V AC) Installed on DIN rail TS-35 / 7.5 or 15 Built-in active PFC function, PF > 0.95 150% peak load capability 100% full load burn-in test Protection: SCP, OLP, OVP, OTP Two selectable peak load modes Built-in DC OK Relay contact Built-in Remote ON / OFF function 3 years warranty UL 508 Cat. No. PSC-15124 PSC-15148 DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER PEAK CURRENT PEAK POWER 24V 6.3A 0~6.3A 150W 9.45A 225W (3sec.) 48V 3.2A 0~3.2A 150W 4.8A 3 seconds or 20% duty cycle max. and the average output power should not exceed the rate power. RIPPLE & NOISE (max) 240mVp-p 480mVp-p Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1µF & 47µF parallel capacitor. VOLTAGE ADJ. RANGE VOLTAGE TOLERANCE -2% ~ +8% ±1.0% -2% ~ +8% ±1.0% Tolerance: includes set up tolerance, line regulation and load regulation. INPUT LINE REGULATION LOAD REGULATION SETUP, RISE TIME HOLD UP TIME (Typ.) VOLTAGE RANGE ±0.5% ±1.0% 700ms, 30ms / 230VAC / 115VAC at full load 16ms / 230VAC; 16ms / 115VAC at full load ±0.5% ±1.0% 88 ~ 264VAC; 124 ~ 373VDC Derating may apply in low input voltage. Please check the derating curve for more details. PROTECTION FREQUENCY RANGE POWER FACTOR(Typ.) EFFICIENCY (Typ.) AC CURRENT (Typ.) INRUSH CURRENT (Typ.) LEAKAGE CURRENT 47 ~ 63Hz 0.9 / 230VAC; 0.98 / 115VAC at full load 87% 2.6A / 115VAC; 1.3A / 230VAC 33A / 115VAC; 65A / 230VAC <1mA/ 240VAC OVERLOAD Normally works within 105% ~ 150% rated output power for more than 3sec and then shutdown O/P voltage with outo-recovery, > 150% rated power or short circuit is constant current limiting, if o/p drop to 40% rating output voltage then shutdown and auto-recover 5 time, if faul condition not remove in this 5 time, the system well be shutdown and re-power on to recover. OVER VOLTAGE 29 ~ 33V 87% 56 ~ 65V Protection type: Latch-off mode, repower on to recover. OVER TEMPERATURE ENVIRONMENT 95 ±5°C (TSW: detect on heatsink of power diode) Protection type: Shut down o/p voltage, recovers automatically after temperature goes down WORKING TEMP. -10 ~ +70°C (Refer to derating curve) Installation clearance: 40mm from top, 20mm from bottom, 5mm from the left and right side are recommended when loaded permanently with full power. In case the adjacent device is a heat source, 15mm clearance is recommended. SAFETY & EMC OTHERS WORKING HUMIDITY STORAGE TEMP. / HUMIDITY TEMP. COEFFICIENT VIBRATION 20 ~ 95% RH non-condensing -40 ~ +85°C, 10 ~ 95% RH ±0.03% / °C (0 ~ 50°C) 10 ~ 500Hz, 2G 10min. / 1cycle, 60min. each along X, Y, Z axes SAFETY STANDARDS WITHSTAND VOLTAGE ISOLATION RESISTANCE EMI CONDUCTION & RADIATION HARMONIC CURRENT EMS IMMUNITY UL 508 / TUV EN 60950-1 I/P-O/P: 4242VDC, I/P-FG: 2121VDC, O/P-FG: 707VDC, O/P-DC OK: 707VDC I/P-O/P, I/P-FG, O/P-FG: >100M Ohms / 500VDC / 25°C / 70% RH EN55022 (CISPR22) Class B EN61000-3-2, -3 Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204; EN55024; EN61000-6-2; (EN50082-2); EN61204-3; heavy industry level; criteria A, MEET SEMI F47 The power supply is considered a component which will installed into a final equipment. The final equipment must be re-confirmed that is still meets EMC directives. DC OK RELAY. CONTACT RATINGS (max) MTBF DIMENSION PACKING COOLING 60VDC / 0.3A, 30VDC / 1A, 30VAC / 0.5A resistive load 62.7K HRS (MIL-HDBK-217F) 55.5x125.2x99.8 mm (WxHxD) 0.9kg; 12pcs / 12.8kg Free air convection All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature. 30 For the latest on Altech Power Supplies please visit www.altechcorp.com/power. PowerSupplies_2013.QXD_PowerSupplies(v5).QXD 9/18/13 5:03 PM Page 31 PSC-151 Series Type Approved E205412 ENERGY SAVER Mechanical Drawings Unit : mm / inch Terminal Pin No. Assignment (TB1) Assignment Pin NO. 1 2 3 FG AC/L AC/N Terminal Pin No. Assignment (TB2) 55.5 Assignment Pin NO. 1 2 3 4 5,6 DC+ DCINH+ INHRelay Contact 99.8 123456 TB2 Relay Contact + +V ADJ. Switch No. Assignment ON Assignment SW NO. SW1 SW2 OFF SW1 SW2 PEAK LOAD SETTING REMOTE ON/OFF SETTING 125.2 DC ON 1 2 3 TB1 Block Diagram I/P EMI FIL TER & RECTIFIERS PFC CIRCUIT POWER SWITCHING RECTIFIERS & FIL TER +V -V O.C.P . FG O.L.P . O.L.P . O.L.P . DETECTION CIRCUIT AC DETECTION CIRCUIT PWM & PFC CONTROL MICRO CIRCUIT O.V .P. O.T .P. REMOTE CONTROL R e la y C INH+ INH- PEAK LOAD CONTROL DC OK Relay Contact Contact Close Contact Open Contact Ratings(max.) When the output voltage reaches the adjusted output voltage. When the output voltage drop below 45% rated output voltage. 30V/1A resistive load Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 31 PowerSupplies_2013.QXD_PowerSupplies(v5).QXD 9/18/13 5:03 PM Page 32 PSC-151 Series E205412 Type Approved ENERGY SAVER Peak Load SW1 ON (Mode1) Default setting I T-peak I-peak T-peak presents while the unit is working within 110%~150% Rating output power. See curve " B " for the variation in T-peak between output current and holdup time. If T-peak is more than the time setting in curve "B", the output current will drop to the constant current limit (I-normal) that is 105% rating power, meanwhile, I- normal and T-normal will be presenting. See curve "A" for the timing back to I-Peak of T-normal and this Mode can use for easy 2-stage battery charger. I-normal T-normal 0 T Peak Load SW2 OFF (Mode2) I T-peak I-peak T-peak presents while the unit is working within 110%~150% Rating output power. See curve " B " for the variation in T-peak between output current and holdup time. If T-peak is more than the time setting in curve "B", the output current will be shut down for 3~4 sec, then auto-recovery. 0 3 ~ 4 sec T- n ormal (Sec.) T- peak 24 22 20 18 16 14 12 10 8 6 4 2 0 22 20 18 16 14 12 10 8 6 4 2 0 10 % 20 % 30 % 40 % 50 % 60 % 70 % 80 % 90 % Load (%) CURVE A 32 T I- normal (Sec.) 110% 115% 120% 125% 130% 135% 140% 145% 150% I- peak Load (%) CURVE B For the latest on Altech Power Supplies please visit www.altechcorp.com/power. PowerSupplies_2013.QXD_PowerSupplies(v5).QXD 9/18/13 5:03 PM Page 33 PSC-151 Series E205412 ENERGY SAVER Remote ON/OFF External Power Source I = 6 ~ 20mA SW 123456 T he P S U c a n be turne d O N /O F F by us ing the "R e mote C ontrol" func tion. SW2 INH+(3 PIN)/ INH-(4 PIN) Output Status OFF SW ON (>2.5V) ENABLE OFF SW OFF (<0.8V) DISABLE ON SW ON (>2.5V) DISABLE DISABLE ON SW OFF (<0.8V) ENABLE TB2 Relay Contact + +V ADJ. (De fault S etting) DC ON ON OFF SW1 SW2 Derating Curve 150 Load (%) 112.5 For typ. 3sec 100 60 Continuous 40 -10 0 10 20 30 40 50 60 70 (V ertical) Ambient Temperature (°C) AC=230 / 1 15V AC Output derating VS input coltage 100 90 Load (%) Type Approved 80 70 60 50 40 88 100 110 135 230 264VAC Input Voltage (V) 60Hz Ta=25 °C Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 33 PowerSupplies_2013.QXD_PowerSupplies(v5).QXD 9/18/13 5:03 PM Page 34 PSC-241 Series Type Approved OUTPUT E205412 ENERGY SAVER Features: • • • • • • • • • • • • Universal AC input (88-264V AC) High efficiency 92% and low power dissipation Installed on DIN rail TS-35 / 7.5 or 15 Built-in active PFC function, PF > 0.95 150% peak load capability 100% full load burn-in test Protection: SCP, OLP, OVP, OTP Two selectable peak load modes Built-in DC OK Relay contact Built-in Remote ON / OFF function 3 years warranty UL 508 Cat. No. PSC-24124 PSC-24148 DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER PEAK CURRENT PEAK POWER 24V 10A 0~10A 240W 15A 360W (3sec.) Two selectable peak load modes 48V 5A 0~5A 240W 7.5A 3 seconds or 20% duty cycle Max. The average output power should not exceed the rate power. RIPPLE & NOISE (max) 150mVp-p 300mVp-p Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1µF & 47µF parallel capacitor. VOLTAGE ADJ. RANGE VOLTAGE TOLERANCE -2% ~ +8% ±1.0% -2% ~ +8% ±1.0% Tolerance: includes set up tolerance, line regulation and load regulation. INPUT LINE REGULATION LOAD REGULATION SETUP, RISE TIME HOLD UP TIME (Typ.) VOLTAGE RANGE ±0.5% ±1.0% 700ms, 30ms / 230VAC / 115VAC at full load 20ms / 230VAC; 20ms / 115VAC at full load ±0.5% ±1.0% 88 ~ 264VAC; 124 ~ 373VDC Derating may apply in low input voltage. Please check the derating curve for more details. PROTECTION FREQUENCY RANGE POWER FACTOR (Typ.) EFFICIENCY (Typ.) AC CURRENT (Typ.) INRUSH CURRENT (Typ.) LEAKAGE CURRENT 47 ~ 63Hz 0.96 / 230VAC; 0.96 / 115VAC at full load 91% 2.6A / 115VAC; 1.3A / 230VAC 33A / 115VAC; 65A / 230VAC <1mA/ 240VAC OVERLOAD >150% rated power or short circuit is constant current limiting. if o/p drop to 40% rating output voltage then shutdown and auto-recover 5 time, if fault condition not remove in this 5 time, the system well be shutdown and re-power on to recover. OVER VOLTAGE 28 ~ 33V 92% 56 ~ 65V Protection type: Shut down O/P voltage with auto-recovery OVER TEMPERATURE 95 ±5°C (TSW: detect on heatsink of power diode) Protection type: Shut down o/p voltage, recovers automatically after temperature goes down ENVIRONMENT WORKING TEMP. -25 ~ +70˚C (Refer to output load derating curve) Installation clearances: 40mm on top, 20mm on the bottom, 5mm on the left and right side are recommended when loaded permanently with full power. In case the adjacent device is a heat source, 15mm clearance is recommended. SAFETY & EMC WORKING HUMIDITY STORAGE TEMP. / HUMIDITY TEMP. COEFFICIENT VIBRATION 20 ~ 95% RH non-condensing -40 ~ +85˚C; 10 ~ 95% RH ±0.03% ˚C (0 ~ 50˚C) 10 ~ 500Hz, 2G 10min. / 1cycle, 60 min. each long X,Y, Z axes SAFETY STANDARDS WITHSTAND VOLTAGE ISOLATION RESISTANCE EMI CONDUCTION & RADIATION HARMONIC CURRENT EMS IMMUNITY UL508, TUV EN60950-1 I/P-O/P: 4242VDC I/P-FG2121VDC O/P-F/G: 707VDC O/P-DC OK: 707VDC I/P-O/P, I/P-FG, O/P-FG: > 100M Ohms / 500VDC / 25°C / 70% RH EN55022:2006 Class B EN61000-3-2: 2006 Class A, ENG1000-3-3: 1995+A1: 2001+A2: 2005 EN61204-3: 2000, EN55024: 1998+A1: 2001+A2: 2003 light industry level, criteria A The power supply is considered a component which will installed into a final equipment. The final equipment must be re-confirmed that is still meets EMC directives. OTHERS DC OK RELAY CONTACT RATINGS (max) MTBF DIMENSION PACKING COOLING 60VDC / 0.3A, 30VDC / 1A, 30VAC / 0.5A resistive load 57K HRS (MIL-HDBK-217F) 65.8x125.2x117.7 mm (WxHxD) 0.9kg; 12pcs / 12.8kg Free air convection All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature. 34 For the latest on Altech Power Supplies please visit www.altechcorp.com/power. PowerSupplies_2013.QXD_PowerSupplies(v5).QXD 9/18/13 5:03 PM Page 35 PSC-241 Series Type Approved E205412 ENERGY SAVER Mechanical Drawings Unit : mm / inch Terminal Pin No. Assignment (TB1) Assignment Pin NO. 1 2 3 FG AC/L AC/N Terminal Pin No. Assignment (TB2) Assignment Pin NO. 1 2 3 4 5,6 DC+ DCINH+ INHRelay Contact 65.8 65.80 117.7 117.7 123456 TB2 Relay Contact + +V ADJ. Switch No. Assignment DC ON ON SW1 SW2 OFF 125.2 Assignment SW NO. SW1 SW2 PEAK LOAD SETTING REMOTE ON/OFF SETTING 1 2 3 TB1 Block Diagram I/P ACTIVE INRUSH CURRENT LIMITING EMI FIL TER & RECTIFIERS PFC CIRCUIT POWER SWITCHING RECTIFIERS & FIL TER +V -V O.C.P . FG O.L.P . AC DETECTION CIRCUIT O.L.P . DETECTION CIRCUIT PFC CONTROL PWM POWER CONTROL MICRO CIRCUIT O.V .P. O.T .P. REMOTE CONTROL R e la y C onta c t INH+ INH- PEAK LOAD CONTROL DC OK Relay Contact Contact Close Contact Open Contact Ratings(max.) When the output voltage reaches the adjusted output voltage. When the output voltage drop below 45% rated output voltage. 30V/1A resistive load Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 35 PowerSupplies_2013.QXD_PowerSupplies(v5).QXD 9/18/13 5:03 PM Page 36 PSC-241 Series E205412 Type Approved ENERGY SAVER Peak Load SW1 ON (Mode1) Default setting I T-peak I-peak T-peak presents while the unit is working within 110%~150% Rating output power. See curve " B " for the variation in T-peak between output current and holdup time. If T-peak is more than the time setting in curve "B", the output current will drop to the constant current limit (I-normal) that is 105% rating power, meanwhile, I- normal and T-normal will be presenting. See curve "A" for the timing back to I-Peak of T-normal and this Mode can use for easy 2-stage battery charger. I-normal T-normal 0 T Peak Load SW2 OFF (Mode2) I T-peak I-peak T-peak presents while the unit is working within 110%~150% Rating output power. See curve " B " for the variation in T-peak between output current and holdup time. If T-peak is more than the time setting in curve "B", the output current will be shut down for 3~4 sec, then auto-recovery. 0 3 ~ 4 sec T- n ormal (Sec.) T- peak 24 22 20 18 16 14 12 10 8 6 4 2 0 22 20 18 16 14 12 10 8 6 4 2 0 10 % 20 % 30 % 40 % 50 % 60 % 70 % 80 % 90 % Load (%) CURVE A 36 T I- normal (Sec.) 110% 115% 120% 125% 130% 135% 140% 145% 150% I- peak Load (%) CURVE B For the latest on Altech Power Supplies please visit www.altechcorp.com/power. PowerSupplies_2013.QXD_PowerSupplies(v5).QXD 9/18/13 5:03 PM Page 37 PSC-241 Series Type Approved E205412 ENERGY SAVER Remote ON/OFF SW External Power Source I = 6 ~ 20mA 123456 T he P S U c a n be turne d O N /O F F by us ing the "R e mote C ontrol" func tion. TB2 SW2 INH+(3 PIN)/ INH-(4 PIN) Output Status OFF SW ON (>2.5V) ENABLE OFF SW OFF (<0.8V) DISABLE ON SW ON (>2.5V) DISABLE DISABLE ON SW OFF (<0.8V) ENABLE DC OK + +V ADJ. DC ON (De fault S etting) ON SW1 SW2 OFF Derating Curve 150 Load (%) 112.5 For typ. 3sec 100 60 Continuous 40 -10 0 10 20 30 40 50 60 70 (V ertical) Ambient Temperature (°C) AC=230 / 1 15V AC Output derating VS input coltage 100 Load (%) 90 80 70 60 50 40 k 88 100 110 135 230 264VAC Input Voltage(V)60Hz Ta=25 °C Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 37 PowerSupplies_2013.QXD_PowerSupplies(v5).QXD 9/18/13 5:03 PM Page 38 PSC-481 Series Type Approved OUTPUT E205412 ENERGY SAVER Features: • • • • • • • • • • Universal AC input (88-264V AC) Installed on DIN rail TS-35 / 7.5 or 15 Built-in active PFC function, PF > 0.95 150% peak load capability Protection: SCP, OLP, OVP, OTP Two selectable peak load modes Built-in DC OK (Open Collector Signal) Built-in Remote ON / OFF function 3 years warranty UL 508 Cat. No. PSC-48124 PSC-48148 DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER PEAK CURRENT PEAK POWER 24V 20A 0~20A 480W 30A 720W (3sec.) Two selectable peak load modes 48V 10A 0~10A 480W 15A RIPPLE & NOISE (max) 240mVp-p 3 seconds or 20% duty cycle Max. The average output power should not exceed the rate power. 480mVp-p Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1µF & 47µF parallel capacitor. VOLTAGE ADJ. RANGE VOLTAGE TOLERANCE -5% ~ +5% ±1.0% ±1.0% Tolerance: includes set up tolerance, line regulation and load regulation. INPUT LINE REGULATION LOAD REGULATION SETUP, RISE TIME HOLD UP TIME (Typ.) VOLTAGE RANGE ±0.5% ±1.0% 800ms, 100ms / 230VAC / 115VAC at full load 16ms / 230VAC; 16ms / 115VAC at full load ±0.5% ±1.0% 88 ~ 264VAC; 124 ~ 373VDC Derating may apply in low input voltage. Please check the derating curve for more details. PROTECTION FREQUENCY RANGE POWER FACTOR (Typ.) EFFICIENCY (Typ.) AC CURRENT (Typ.) IMRUSH CURRENT (Typ.) LEAKAGE CURRENT 47 ~ 63Hz 0.96 / 230VAC / 115VAC at full load 93% 5.0A / 115VAC; 2.5A / 230VAC 33A / 115VAC; 65A / 230VAC < 1mA/ 240VAC OVERLOAD Hiccup mode: when the rated output power is within 105% ~ 150% for more than 3secs. Constant current limit: > 150% rated power / short circuit Auto-recovery: If O/P drop to 40% of the rated output voltage, PSU will shut down and auto-recover 5times (If fault condition remains after 5times recovery, PSU will shut down. User must re-power on to recover) OVER VOLTAGE 29 ~ 33V 94% 56 ~ 65V Protection type: Latch-off mode. OVER TEMPERATURE 95 ±5°C (TSW: detect on heatsink of power diode) Protection type: Shut down o/p voltage, recovers automatically after temperature goes down ENVIRONMENT WORKING TEMP. -20 ~ +70˚C (Refer to output load derating curve) Installation clearance: 40mm from top, 20mm from the left and right side are recommended when loaded permanently with full power. In case the adjacent device is a heat sorce, 15mm clearance is recomended. SAFETY & EMC WORKING HUMIDITY STORAGE TEMP. / HUMIDITY TEMP. COEFFICIENT VIBRATION 20 ~ 95% RH non-condensing -40 ~ +85˚C; 10 ~ 95% RH ±0.03% ˚C (0 ~ 50˚C) 10 ~ 500Hz, 2G 10min. / 1cycle, 60 min. each long X,Y, Z axes SAFETY STANDARDS WITHSTAND VOLTAGE ISOLATION RESISTANCE EMI CONDUCTION & RADIATION HARMONIC CURRENT EMS IMMUNITY UL 508 / EN 60950-1 I/P-O/P: 4242VDC, I/P-FG: 2121VDC, O/P-FG: 707VDC, O/P-DC OK: 707VDC I/P-O/P, I/P-FG, O/P-FG: >100M Ohms / 500VDC / 25°C / 70% RH EN 55022 (CISPR22), EN 61000-6-3 EN61000-3-2, -3-3 IEC 61000-4-2, 3, 4, 5, 6, 8, 11; EN 61000-6-1; EN 61204-3 The power supply is considered a component which will installed into a final equipment. The final equipment must be re-confirmed that is still meets EMC directives. OTHERS DC OK RELAY CONTACT RATINGS (max) DIMENSION PACKING 60VDC / 0.3A, 30VDC / 1A, 30VAC / 0.5A resistive load 86.3x124.8x123.4 mm (WxHxD) 1.45kg; 8pcs / 12kg All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature. 38 For the latest on Altech Power Supplies please visit www.altechcorp.com/power. PowerSupplies_2013.QXD_PowerSupplies(v5).QXD 9/18/13 5:03 PM Page 39 PSC-481 Series Type Approved E205412 ENERGY SAVER Mechanical Drawings Unit : mm / inch Terminal Pin No. Assignment (TB1) Assignment Pin NO. 1 2 3 FG AC/L AC/N Te rmina l P in N o. A s s ignme nt ( T B 2) Assignment Pin NO. 1-3 4-6 7 8 9,10 86.3 DC+ DCINH+ INHDC OK Singal 123.4 1 2 3 4 5 6 7 8 910 TB2 DC OK + +V ADJ. Switch No. Assignment DC ON ON OFF 124.8 Assignment SW NO. SW1 SW2 SW1 SW2 PEAK LOAD SETTING REMOTE ON/OFF SETTING 1 2 3 TB1 Block Diagram I/P ACTIVE iNRUSH CURRENT LIMITING EMI FIL TER & RECTIFIERS PFC CIRCUIT POWER SWITCHING RECTIFIERS & FIL TER +V -V O.C.P . FG O.L.P . AC DETECTION CIRCUIT O.L.P . DETECTION CIRCUIT PFC CONTROL PWM POWER CONTROL MICRO CIRCUIT O.V .P. D C O K S inga l O.T .P. REMOTE CONTROL INH+ INH- PEAK LOAD CONTROL DC OK Relay Contact Contact Ratings(max.) Isolation V oltage CTR : MIN. 50% at IF = 5mA, V CE = 5V Between input and output V iso = 3750V rms Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 39 PowerSupplies_2013.QXD_PowerSupplies(v5).QXD 9/18/13 5:03 PM Page 40 PSC-481 Series E205412 Type Approved ENERGY SAVER Peak Load SW1 ON (Mode1) Default setting I T-peak I-peak T-peak presents while the unit is working within 110%~150% Rating output power. See curve " B " for the variation in T-peak between output current and holdup time. If T-peak is more than the time setting in curve "B", the output current will drop to the constant current limit (I-normal) that is 105% rating power, meanwhile, I- normal and T-normal will be presenting. See curve "A" for the timing back to I-Peak of T-normal and this Mode can use for easy 2-stage battery charger. I-normal T-normal 0 T Peak Load SW2 OFF (Mode2) I T-peak I-peak T-peak presents while the unit is working within 110%~150% Rating output power. See curve " B " for the variation in T-peak between output current and holdup time. If T-peak is more than the time setting in curve "B", the output current will be shut down for 3~4 sec, then auto-recovery. 0 3 ~ 4 sec T- n ormal (Sec.) T- peak 24 22 20 18 16 14 12 10 8 6 4 2 0 22 20 18 16 14 12 10 8 6 4 2 0 10 % 20 % 30 % 40 % 50 % 60 % 70 % 80 % 90 % Load (%) CURVE A 40 T I- normal (Sec.) 110% 115% 120% 125% 130% 135% 140% 145% 150% I- peak Load (%) CURVE B For the latest on Altech Power Supplies please visit www.altechcorp.com/power. PowerSupplies_2013.QXD_PowerSupplies(v5).QXD 9/18/13 5:03 PM Page 41 PSC-481 Series Type Approved E205412 ENERGY SAVER Remote ON/OFF SW External Power Source I = 6 ~ 20mA 123456 T he P S U c a n be turne d O N /O F F by us ing the "R e mote C ontrol" func tion. TB2 SW2 INH+(3 PIN)/ INH-(4 PIN) Output Status OFF SW ON (>2.5V) ENABLE OFF SW OFF (<0.8V) DISABLE ON SW ON (>2.5V) DISABLE DISABLE ON SW OFF (<0.8V) ENABLE DC OK + +V ADJ. DC ON (De fault S etting) ON SW1 SW2 OFF Derating Curve 150 Load (%) 112.5 For typ. 3sec 100 60 Continuous 40 -10 0 10 20 30 40 50 60 70 (V ertical) Ambient Temperature (°C) AC=230 / 1 15V AC Output derating VS input coltage 100 Load (%) 90 80 70 60 50 40 ak 88 100 110 135 230 264VAC Input Voltage(V)60Hz Ta=25 °C Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 41