PowerSupplies_2013.QXD_PowerSupplies(v5).QXD 9/18/13 3:43 PM Page 30 PSC-151 Series Type Approved OUTPUT E205412 Features: ENERGY SAVER • • • • • • • • • • • Universal AC input (88-264V AC) Installed on DIN rail TS-35 / 7.5 or 15 Built-in active PFC function, PF > 0.95 150% peak load capability 100% full load burn-in test Protection: SCP, OLP, OVP, OTP Two selectable peak load modes Built-in DC OK Relay contact Built-in Remote ON / OFF function 3 years warranty UL 508 Cat. No. PSC-15124 PSC-15148 DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER PEAK CURRENT PEAK POWER 24V 6.3A 0~6.3A 150W 9.45A 225W (3sec.) 48V 3.2A 0~3.2A 150W 4.8A 3 seconds or 20% duty cycle max. and the average output power should not exceed the rate power. RIPPLE & NOISE (max) 240mVp-p 480mVp-p Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1µF & 47µF parallel capacitor. VOLTAGE ADJ. RANGE VOLTAGE TOLERANCE -2% ~ +8% ±1.0% -2% ~ +8% ±1.0% Tolerance: includes set up tolerance, line regulation and load regulation. INPUT LINE REGULATION LOAD REGULATION SETUP, RISE TIME HOLD UP TIME (Typ.) VOLTAGE RANGE ±0.5% ±1.0% 700ms, 30ms / 230VAC / 115VAC at full load 16ms / 230VAC; 16ms / 115VAC at full load ±0.5% ±1.0% 88 ~ 264VAC; 124 ~ 373VDC Derating may apply in low input voltage. Please check the derating curve for more details. PROTECTION FREQUENCY RANGE POWER FACTOR(Typ.) EFFICIENCY (Typ.) AC CURRENT (Typ.) INRUSH CURRENT (Typ.) LEAKAGE CURRENT 47 ~ 63Hz 0.9 / 230VAC; 0.98 / 115VAC at full load 87% 2.6A / 115VAC; 1.3A / 230VAC 33A / 115VAC; 65A / 230VAC <1mA/ 240VAC OVERLOAD Normally works within 105% ~ 150% rated output power for more than 3sec and then shutdown O/P voltage with outo-recovery, > 150% rated power or short circuit is constant current limiting, if o/p drop to 40% rating output voltage then shutdown and auto-recover 5 time, if faul condition not remove in this 5 time, the system well be shutdown and re-power on to recover. OVER VOLTAGE 29 ~ 33V 87% 56 ~ 65V Protection type: Latch-off mode, repower on to recover. OVER TEMPERATURE ENVIRONMENT 95 ±5°C (TSW: detect on heatsink of power diode) Protection type: Shut down o/p voltage, recovers automatically after temperature goes down WORKING TEMP. -10 ~ +70°C (Refer to derating curve) Installation clearance: 40mm from top, 20mm from bottom, 5mm from the left and right side are recommended when loaded permanently with full power. In case the adjacent device is a heat source, 15mm clearance is recommended. SAFETY & EMC OTHERS WORKING HUMIDITY STORAGE TEMP. / HUMIDITY TEMP. COEFFICIENT VIBRATION 20 ~ 95% RH non-condensing -40 ~ +85°C, 10 ~ 95% RH ±0.03% / °C (0 ~ 50°C) 10 ~ 500Hz, 2G 10min. / 1cycle, 60min. each along X, Y, Z axes SAFETY STANDARDS WITHSTAND VOLTAGE ISOLATION RESISTANCE EMI CONDUCTION & RADIATION HARMONIC CURRENT EMS IMMUNITY UL 508 / TUV EN 60950-1 I/P-O/P: 4242VDC, I/P-FG: 2121VDC, O/P-FG: 707VDC, O/P-DC OK: 707VDC I/P-O/P, I/P-FG, O/P-FG: >100M Ohms / 500VDC / 25°C / 70% RH EN55022 (CISPR22) Class B EN61000-3-2, -3 Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204; EN55024; EN61000-6-2; (EN50082-2); EN61204-3; heavy industry level; criteria A, MEET SEMI F47 The power supply is considered a component which will installed into a final equipment. The final equipment must be re-confirmed that is still meets EMC directives. DC OK RELAY. CONTACT RATINGS (max) MTBF DIMENSION PACKING COOLING 60VDC / 0.3A, 30VDC / 1A, 30VAC / 0.5A resistive load 62.7K HRS (MIL-HDBK-217F) 55.5x125.2x99.8 mm (WxHxD) 0.9kg; 12pcs / 12.8kg Free air convection All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature. 30 For the latest on Altech Power Supplies please visit www.altechcorp.com/power. PowerSupplies_2013.QXD_PowerSupplies(v5).QXD 9/18/13 3:43 PM Page 31 PSC-151 Series Type Approved E205412 ENERGY SAVER Mechanical Drawings Unit : mm / inch Terminal Pin No. Assignment (TB1) Assignment Pin NO. 1 2 3 FG AC/L AC/N Terminal Pin No. Assignment (TB2) 55.5 Assignment Pin NO. 1 2 3 4 5,6 DC+ DCINH+ INHRelay Contact 99.8 123456 TB2 Relay Contact + +V ADJ. Switch No. Assignment ON Assignment SW NO. SW1 SW2 OFF SW1 SW2 PEAK LOAD SETTING REMOTE ON/OFF SETTING 125.2 DC ON 1 2 3 TB1 Block Diagram I/P EMI FIL TER & RECTIFIERS PFC CIRCUIT POWER SWITCHING RECTIFIERS & FIL TER +V -V O.C.P . FG O.L.P . O.L.P . O.L.P . DETECTION CIRCUIT AC DETECTION CIRCUIT PWM & PFC CONTROL MICRO CIRCUIT O.V .P. O.T .P. REMOTE CONTROL R e la y C INH+ INH- PEAK LOAD CONTROL DC OK Relay Contact Contact Close Contact Open Contact Ratings(max.) When the output voltage reaches the adjusted output voltage. When the output voltage drop below 45% rated output voltage. 30V/1A resistive load Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 31 PowerSupplies_2013.QXD_PowerSupplies(v5).QXD 9/18/13 3:43 PM Page 32 PSC-151 Series E205412 Type Approved ENERGY SAVER Peak Load SW1 ON (Mode1) Default setting I T-peak I-peak T-peak presents while the unit is working within 110%~150% Rating output power. See curve " B " for the variation in T-peak between output current and holdup time. If T-peak is more than the time setting in curve "B", the output current will drop to the constant current limit (I-normal) that is 105% rating power, meanwhile, I- normal and T-normal will be presenting. See curve "A" for the timing back to I-Peak of T-normal and this Mode can use for easy 2-stage battery charger. I-normal T-normal 0 T Peak Load SW2 OFF (Mode2) I T-peak I-peak T-peak presents while the unit is working within 110%~150% Rating output power. See curve " B " for the variation in T-peak between output current and holdup time. If T-peak is more than the time setting in curve "B", the output current will be shut down for 3~4 sec, then auto-recovery. 0 3 ~ 4 sec T- n ormal (Sec.) T- peak 24 22 20 18 16 14 12 10 8 6 4 2 0 22 20 18 16 14 12 10 8 6 4 2 0 10 % 20 % 30 % 40 % 50 % 60 % 70 % 80 % 90 % Load (%) CURVE A 32 T I- normal (Sec.) 110% 115% 120% 125% 130% 135% 140% 145% 150% I- peak Load (%) CURVE B For the latest on Altech Power Supplies please visit www.altechcorp.com/power. PowerSupplies_2013.QXD_PowerSupplies(v5).QXD 9/18/13 3:43 PM Page 33 PSC-151 Series E205412 ENERGY SAVER Remote ON/OFF External Power Source I = 6 ~ 20mA SW 123456 T he P S U c a n be turne d O N /O F F by us ing the "R e mote C ontrol" func tion. SW2 INH+(3 PIN)/ INH-(4 PIN) Output Status OFF SW ON (>2.5V) ENABLE OFF SW OFF (<0.8V) DISABLE ON SW ON (>2.5V) DISABLE DISABLE ON SW OFF (<0.8V) ENABLE TB2 Relay Contact + +V ADJ. (De fault S etting) DC ON ON OFF SW1 SW2 Derating Curve 150 Load (%) 112.5 For typ. 3sec 100 60 Continuous 40 -10 0 10 20 30 40 50 60 70 (V ertical) Ambient Temperature (°C) AC=230 / 1 15V AC Output derating VS input coltage 100 90 Load (%) Type Approved 80 70 60 50 40 88 100 110 135 230 264VAC Input Voltage (V) 60Hz Ta=25 °C Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 33