ECI8020K1D00 1587847

ECI Motor
ECI-80.20-K1
- Highly dynamic 3-phase internal rotor motor with EC technology
- Robust, noise-optimized ball bearing system for a long service life
- Mechanical design and interfaces designed for modular flexibility
- High efficiency and high power density realized in a compact design
-B
asic motor with electronic module K1 for operation with external
drive electronics
- Protection rating IP 40 / IP 54 and connection by connector system
Nominal data
Type
ECI-80.20-K1 B00
ECI-80.20-K1 D00
Nominal voltage (UN)
VDC
24
48
Nominal speed (nN)**
rqm
4000**
4000**
Nominal torque (M N)**
mNm
700**
700**
Nominal current (I N)**
A
13.5**
7.5**
Nominal output power (PN)**
W
293**
293**
Free-running speed (nL)
min
4800
4800
Permanent holding torque (M NO)
mNm
700
700
Permiss. peak current (Imax)***
A
100***
60***
Motor constant (KE)
mVs/rad
47.2
94.1
Terminal resistance (R V)
Ω
0.07
0.3
Terminal inductance (L V)
mH
0.3
1.3
Starting torque (Mmax)
mNm
2400
2500
Ambient temperature range (TU)
°C
-30...+40
-30...+40
Rotor moment of inertia (J R)
kgm2 x10–6
54
54
Motor mass (m)
kg
1.4
1.4
Order number (IP 40)
Wire interface
932 8020 103
932 8020 105
Order number (IP 54)*
Connector interface
on request
on request
subject to alterations
*
–1
Classification of protection class reters to installed state with sealing on the flange side
** At TU max. 40 °C / 104 °F
*** Permissible time for peak current: max. 5 sec.- to be repeated only after complete cool down
F radial
F axial
Faxial
280 N
Permissible shaft load at nominal speed and
Fradial
280 N
life expectancy L10 of 20 000 h**
L 1 = 20 mm
L1
ECI-80.20-K1-B00, 24V (at 25°C / 77° F)
6500
ECI-80.20-K1-D00, 48V (at 25°C / 77° F)
Mmax
Mn
6000
6500
120
5500
120
80
3500
3000
60
2500
2000
40
1500
1000
20
Continuous
operation
500
0
0
200
400
n = Speed, f (M)
Nominal data, see table above
800
1000
1200
1400
Torque M [mNm]
I = Current, f (M)
1600
1800
2000
4000
3000
60
2500
40
2000
1500
1000
0
2200
80
Operating
point 1)
3500
0
2400
0
η = Efficiency, f (M)
20
Continuous
operation
500
Short-time operation
600
4500
200
400
600
Short-time operation
800
n = Speed, f (M)
1)
1000
1200
1400
1600
Torque M [mNm]
I = Current, f (M)
1800
2000
2200
Current I [A]; Efficiency η [%]
4000
100
5000
Speed n [min-1]
Operating point 1)
Current I [A]; Efficiency η [%]
100
4500
Speed n [min-1]
Mmax
5500
5000
1)
Mn
6000
0
2400
2600
η = Efficiency, f (M)
Nominal data, see table above
V4_07/2015
ECI_80.20_K1_EN_V4.indd 1
14.07.2015 16:35:58
ECI Motor
ECI-80.20-K1
Technical drawing
M6
Screw depth
= 13 mm
M5
Screw depth
= 13 mm
M6
Screw depth
= 13 mm
Tapped blind holes for thread-forming screws in accordance
to DIN 7500.
Tightening torque:
M5
6 ± 0.2 Nm
M6
10 ± 0.2 Nm
Accessory (must be ordered separatly)
Connection description Motor (IP 40 version)
Sensor cable with wires and plug AWG 24 (0.22 mm2)
Picture 1 = with cover
(simplyfied design)
Picture 2 = cover removed
(simplyfied design)
Cable outlet sensor cable
Socket for sensor cable
Type
Order number
Sensor cable
992 0800 001
motor side
Winding connector AWG 12 (4 mm2)
Type
Colour
Order number
Power wire L1
brown
992 0800 012
Power wire L2
purple
992 0800 011
Power wire L3
yellow
992 0800 010
L1
L3
L2
motor side
Tightening torque:
Possible gearbox variants
Recommended external control electronics
Type
Type
Order number
on request
VT-MI-35
992 0801 035
ECI_80.20_K1_EN_V4.indd 2
M3
1.5 ± 0.2 Nm
14.07.2015 16:36:03