pdf

www.osram.com
PrevaLED® Bar
Light Engines
1100lm on 280 x 55mm
2200lm on 560 x 55mm
Benefits
Efficiency 155lm/W
•
•
•
•
•
•
•
•
•
Perfect match to LEDiL Florence 3R lenses
Homogeneous light distribution
Consistent white light of 3 SDCM
Seamless: no shadows between modules
Poke-in connectors for 0,5mm² to 0,75mm² wire
Self-cooling
SELV/non-SELV module for easier fixture design
Average lifetime 50.000h L80B10
at Tp (max) = 55°C
• CE, ENEC approval under preparation
Application
• Supermarket
• Industry
Dimension (l x w x h):
• 280mm x 55mm x 6mm
• 560mm x 55mm x 6mm
Typical technical data @rated current*
Flux
CCT
(lm)
(K)
Vf
If
P (W)
lm/W*
(V)
(mA)
Module
Module
PLG2-Bar-1100-830-280x55-DC
1100
3
31
225
7
155
PLG2-Bar-1100-840-280x55-DC
> 80
3
31
225
7
155
6500
> 80
3
31
225
7
155
2200
3000
> 80
3
31
450
14
155
PLG2-Bar-2200-840-560x55-DC
2200
4000
> 80
3
31
450
14
155
PLG2-Bar-2200-865-560x55-DC
2200
6500
> 80
3
31
450
14
155
Product name
CRI
SDCM
3000
> 80
1100
4000
PLG2-Bar-1100-865-280x55-DC
1100
PLG2-Bar-2200-830-560x55-DC
Typical values valid for Tp = 45°C
Energy Efficiency Class according 2012/874/EC: A++
Due to the special conditions of the manufacturing processes of LED the typical data of technical parameters can only reflect statistical figures and do not
necessarily correspond to the actual parameters of each single product which could differ from the typical data.
* Tolerance for optical and electrical data: +/-10%
PrevaLED Bar, December 2015
page 1 of 8
sram.com
Typical performance @max. current*
Flux
CCT
Vf
If
P (W)
lm/W*
(lm)
(K)
(V)
(mA)
Module
Module
PLG2-Bar-1100-830-280x55-DC
1730
3
33
400
13
133
PLG2-Bar-1100-840-280x55-DC
> 80
3
33
400
13
133
6500
> 80
3
33
400
13
133
3460
3000
> 80
3
33
800
26
133
PLG2-Bar-2200-840-560x55-DC
3460
4000
> 80
3
33
800
26
133
PLG2-Bar-2200-865-560x55-DC
3460
6500
> 80
3
33
800
26
133
Product name
CRI
SDCM
3000
> 80
1730
4000
PLG2-Bar-1100-865-280x55-DC
1730
PLG2-Bar-2200-830-560x55-DC
Typical values valid for Tp 45°C
Optical parameters
#
LED
Pitch
(mm)
PLG2-Bar-1100-8xx-280x55-DC
33
26mm
PLG2-Bar-2200-8xx-560x55-DC
66
26mm
Product name
Minimum and Maximum Ratings
Storage
temperature [ °C ]
Tc max.*
(@ typ. current)
L80 B10 @
Tc max. 55°C
PLG2-Bar-1100-8xx-280x55-DC
-35 … 80
80°C
50.000h
PLG2-Bar-2200-8xx-560x55-DC
-35 … 80
80°C
50.000h
Product
,
The modules are designed for operation with OPTOTRONIC® ECG.
*) Exceeding maximum ratings for operating and storage temperature will reduce expected life time or destroy the light engine. The temperature of the LED module must be measured at
the tc-point according to EN60598-1 in thermally settled conditions with a temperature sensor. For exact location of the Tc -point see drawing below (marked as Tc1 and Tc2).
PrevaLED Bar, December 2015
page 2 of 8
ww.osram.com
Temperature derating
104,0%
Relative Flux and Efficacy
102,0%
100,0%
98,0%
Luminous Flux
Efficacy
96,0%
94,0%
92,0%
0
20
40
60
Tcase
80
100
(oC)
L80B10 lifetime [h] as a function of Tp
PLG2-Bar-1100-8xx-280x55-DC
PrevaLED Bar, December 2015
PLG2-Bar-2200-8xx-560x55-DC
page 3 of 8
Modularity
• The tables below show recommended combinations of the PrevaLED® Bar modules and Optotronic®
drivers – but not all possible combinations.
• Calculations in the tables are based on the nominal currents. If currents other than the nominal currents
are requested, the driver – module compatibility tables change.
• Numbers in brackets show possible combinations, but with currents noticeably smaller than the nominal
currents.
• In parallel connection 280mm and 560mm modules can be used together (e.g. to build a 1400mm
luminiare 2 x 560mm modules and 1 x 280 mm modules can be used in parallel connection). In the
modularity tables one 560 mm module counts as two 280 mm modules (e.g. to look up possible driver
matches for the 2 x 560mm and 1 x 280 mm combination mentioned above, the easiest way is to look for
5 x 280 mm in the table).
In serial connection 280mm and 560mm modules can not be used together.
• XsYp is an abbreviation for X modules connected in series, Y modules connected in parallel.
OT FIT CS (triple current driver – SELV)
PrevaLED Bar is designed to be operated by OT FIT SELV drivers in parallel connection*. Current setting
via cable bridge (linear drivers) or selectable output current connectors (compact drivers).
Linear drivers
OT FIT
27V – 54V
OT FIT 80 / 220240 / 1A6 CS L
OT FIT 50 / 220240 / 1A0 CS L
Compact drivers
OTe
OTe
OT FIT 35 / 22025/22025/220240 / 0A7 CS
240/420 CS 240/700
CS
1,2A / 1,4A / 1,55A 0,8A / 0,93A / 1,0A
PrevaLED
Bar
*
0,5A / 0,6A / 0,7A
290 / 350
/ 420 mA
500 / 600
/ 700 mA
360 x 30 x 21mm
280 x 30 x 21mm
280 x 30 x 21mm
88 x 43 x
29.5 mm
88 x 43 x
29.5 mm
PLG2-Bar-11008xx-280x55-DC
5,6,(7)
4
2,3
1
2,3
PLG2-Bar-22008xx-560x55-DC
3
2
1
(1)
1
Final release of modularity under evaluation.
OTi DALI (wide window driver – SELV)
PrevaLED Bar is designed to be operated by OTi DALI drivers in parallel connection*. Current setting via
resistor coding (LEDSet) or Tuner4TRONIC software and DALI magic.
OTi DALI
27V – 54V
OTi DALI 80/220240/2A1 LT2 L
OTi DALI 80/220240/1A6 LT2 L
OTi DALI 50/220240/1A4 LT2 L
OTi DALI 35/220240/700 LT2 L
1,0A – 2,1A
0,6A - 1,55A
0,6A - 1,4A
0,2A – 0,7A
360 x 30 x 21mm
360 x 30 x 21mm
360 x 30 x 21mm
360 x 30 x 21mm
PLG2-Bar-1100-8xx280x55-DC
7,8,9
6
3,4,5
1,2
PLG2-Bar-2200-8xx560x55-DC
4
3
2
1
PrevaLED
Bar
*
Final release of modularity under evaluation.
PrevaLED Bar, December 2015
page 4 of 8
OT FIT D (single current driver – Non-SELV)
PrevaLED Bar is designed to be operated by OT Fit D Non-SELV drivers in serial connection*.
OT Fit D
OT FIT 30/220-240/125 D OT FIT 50/220-240/250 D OT FIT 50/220-240/350 D
L
L
L
125mA, 54V – 216V
250mA, 54V – 216V
350mA, 54V – 150V
210 x 30 x 21mm
210 x 30 x 21mm
210 x 30 x 21mm
PLG2-Bar-11008xx-280x55-DC
(2,3,4,5,6)
2,3,4,5,6
-
PLG2-Bar-22008xx-560x55-DC
-
-
(2,3)
PrevaLED
Bar
*
Final release of modularity under evaluation.
OTi (wide window driver – Non-SELV)
PrevaLED Bar is designed to be operated by OTi and OTi DALI drivers in serial or combined serial-parallel
connection*. Current setting via resistor coding (LEDSet) and for OTi DALI drivers also via Tuner4TRONIC
software and DALI magic.
OTi OTi 60/220-240/550
OTi 90/220OTi DALI 60 550
D LT2 L
240V/1A0 D LT2 L
54V-240V
120mA – 550mA
250mA – 1000mA
125mA – 550mA
250mA – 1000mA
280 x 30 x 21mm
280 x 30 x 21mm
280 x 30 x 21mm
280 x 30 x 21mm
PLG2-Bar-1100-8xx280x55-DC
2,3,4,5 (Xs1p)
6 (3s2p), 8(4s2p)
10 (5s2p)
2,3,4,5 (Xs1p)
6 (3s2p), 8(4s2p)
10 (5s2p)
PLG2-Bar-2200-8xx560x55-DC
2,3,4 (Xs1p)
5 (Xs1p)
2,3,4 (Xs1p)
5 (Xs1p)
PrevaLED
Bar
*
OTi DALI 90 1A0
Final release of modularity under evaluation.
Installation examples
The installation examples 1 and 2 of the PrevaLED® Bar show the scenario of two 280mm modules
connected in series and in parallel to an ECG (the cases 1s2p and 2s1p). Of course the same way of
connecting is possible for the 560 mm modules.
1. Parallel connection (1s2p configuration – 280 mm modules)
2. Serial connection (2s1p configuration – 280 mm modules)
PrevaLED Bar, December 2015
page 5 of 8
This examples can easily expanded to configurations with more than 2 modules, for example 3 modules in
series (3s1p) or 4 modules in parallel – the way of connecting the modules remains the same, but additional
modules are added.
When connecting the modules in parallel to the ECG it is also possible to combine 280 mm and 560 mm
modules. This is not possible for serial connection.
For some cases the best solution is to use a combined serial and parallel connection of the modules. The
picture below shows a possible way of connecting four 280 mm modules in 2s2p configuration.
Please make sure to keep a clearance of minimum 1mm around the PrevaLED® Bar module
If you have any further questions about installation of PrevaLED® Bar Light engines, please consult your
local Osram Sales representative.
Drawings
PrevaLED Bar: PLG2-Bar-1100-8xx-280x55-DC
PrevaLED Bar: PLG2-Bar-2200-8xx-560x55-DC
PrevaLED Bar, December 2015
page 6 of 8
Optics
LEDIL FLORENCE-3R
280mm PrevaLED Bar - PLG2-Bar-1100-8xx-280x55-DC is fully compatible with LEDIL FLORENCE-3R
product family. FLORENCE-3R offers 4 optical versions. FLORENCE symmetrical beam Z30(30deg),
Z60(60deg) and Z90(90deg) applications provide a uniform and low glare light distribution in advanced low
bay environments with 90% efficiency.
FLORENCE asymmetrical beam ZT25 application is designed especially for retail environments where
items are illuminated on shelves on both sides of the aisle. ZT25 provides a uniform double sided
asymmetric beam with a twenty degree tilt optimized to illuminate products on the shelves.
Product Numer
Viewing angle
Light beam
F14486_FLORENCE-Z30
29 deg
Medium
F14112_FLORENCE-Z60
57 deg
Very wide
F13853_FLORENCE-Z90
92 deg
WWW-class
F14170_FLORENCE-ZT25
Asymmertic deg
Asymmetric
F14112_FLORENCE-Z60 ¹
F14486_FLORENCE-Z30 ¹
F14486_FLORENCE-Z30
F14112_FLORENCE-Z90 ¹
F14170_FLORENCE-ZT25 ¹
¹ not rated values
PrevaLED Bar, December 2015
page 7 of 8
Ordering Codes
Product name
EAN (single product)
Type
Shipping Unit
PLG2-Bar-1100-830-280x55-DC
4052899303935
Make to stock
40 x 1
PLG2-Bar-1100-840-280x55-DC
4052899303959
Make to stock
40 x 1
PLG2-Bar-1100-865-280x55-DC
4052899303973
Make to Order
40 x 1
PLG2-Bar-2200-830-560x55-DC
4052899303997
Make to stock
40 x 1
PLG2-Bar-2200-840-560x55-DC
4052899304017
Make to stock
40 x 1
PLG2-Bar-2200-865-560x55-DC
4052899304031
Make to Order
40 x 1
Safety Information
•
The LED module itself and all its components must not be mechanically stressed.
The modules are intended for operation only with matching OPTOTRONIC®.
To also ease the luminaire/installation approval, electronic control gear for LED or LED modules should carry the CE mark and be
ENEC certified. In Europe the declarations of conformity must include the following standards:
CE: EC 61347-2-13, EN 55015, IEC 61547 and IEC 61000-3-2 - ENEC: 61347-2-13 and IEC/EN 62384.
Also check for the mark of an independent authorized certification institute.
Please see the relevant brochure for more detailed information (see "Related and Further Information")
•
Installation of LED modules (with power supplies) needs to be made with regard to all applicable
electrical and safety standards. Only qualified personnel should be allowed to perform installations.
•
Pay attention to standard ESD precautions when installing the module.
•
Photobiological safety according to IEC 62471, risk group RG1
•
Max. Voltage U-OUT = 250V for operation on non-isolated and SELV LED controlgear.
Sales and Technical Support
OSRAM GmbH
Marcel-Breuer-Straße 6 D-
Sales and technical support is given by the
80807 München
local OSRAM subsidiaries.
On our world wide homepage all OSRAM
www.osram.com
+49 89 6213-0
subsidiaries are listed with complete address and
phone numbers.
Note: Typical performance data are subject to change without any further notice, particularly as LED technology evolves.
OSRAM GmbH
Head Office:
Marcel-Breuer-Strasse 6
80807 Munich, Germany
Phone +49 89 6213-0
www.osram.com
PrevaLED Bar, December 2015
page 8 of 8