PrevaLED® Bar Value
Light Engines
•
•
•
•
Benefits
590lm on 132mm
845lm on 200mm
1100lm on 280mm
2200lm on 560mm
•
•
•
•
•
•
•
•
•
•
Efficacy: up to 135 lm/W
Homogeneous light distribution
Consistent white light of 4 SDCM
Poke-in connectors for 0,5mm² wire
No special connection cable needed
Self-cooling
Average lifetime 50.000h
SELV module for easier fixture design
UL, CE, VDE under approval
5 years system warranty in combination
with suitable OPTOTRONIC drivers
Applications
• Office (workplace illumination, corridor)
• Residential
Basic description*
Product name
Flux
(lm)
CCT
(K)
CRI
SDC
M
If
(mA)
P (W)
Module
Tc 55°C
lm/W*
Module
Tc 55°C
L70
B50**
(h)
PLVG1-Bar-590-830-132x48-DC
550
3000
> 80
4
103
5
121
50.000
PLVG1-Bar-590-840-132x48-DC
595
4000
> 80
4
103
5
131
50.000
PLVG1-Bar-845-830-200x48-DC
785
3000
> 80
4
181
6
124
50.000
PLVG1-Bar-845-840-200x48-DC
850
4000
> 80
4
181
6
134
50.000
PLVG1-Bar-1100-830-280x48-DC
1025
3000
> 80
4
255
8
126
50.000
PLVG1-Bar-1100-840-280x48-DC
1100
4000
> 80
4
255
8
135
50.000
PLVG1-Bar-2200-830-560x48-DC
2055
3000
> 80
4
380
17
123
50.000
PLVG1-Bar-2200-840-560x48-DC
2210
4000
> 80
4
380
17
132
50.000
Due to the special conditions of the manufacturing processes of LED the typical data of technical parameters can only reflect statistical figures and do not necessarily correspond to the actual
parameters of each single product which could differ from the typical data.
* Typical value; tolerance for optical and electrical data: +/-10%
**average Lifetime L70B50 (lumen maintenance) up to 50.000h at Tc = 55°C with typical current
PrevaLED Bar Value, April 2014
page 1 of 4
Electrical parameters
Product name
Vf
(V)
If max
(mA)
P max
(mA)
Flux
(lm)
lm/W*
Module
PLVG1-Bar-590-830-132x48-DC
44
140
6
725
121
PLVG1-Bar-590-840-132x48-DC
44
140
6
780
130
PLVG1-Bar-845-830-200x48-DC
35
290
11
1197
109
PLVG1-Bar-845-840-200x48-DC
35
290
11
1289
117
PLVG1-Bar-1100-830-280x48-DC
32
430
15
1681
112
PLVG1-Bar-1100-840-280x48-DC
32
430
15
1810
121
PLVG1-Bar-2200-830-560x48-DC
44
570
26
3039
117
PLVG1-Bar-2200-840-560x48-DC
44
570
26
3273
126
*
Performance data at Tc = 55°C
Minimum and Maximum Ratings
Product
Storage
temperature [ °C ]
Tc max.*
(@ typ. current)
L80 B50 @
Tc max. 85°C
-30 … +80
85°C
tbd h
PLVG1-BAR-xx00-8x0-xxx-DC
The modules are designed for operation with OTp OPTOTRONIC® ECG.
*) Exceeding maximum ratings for operating and storage temperature will reduce expected life time or destroy the light engine. The temperature of the LED module must be measured at the
tc-point according to EN60598-1 in thermally settled conditions with a temperature sensor. For exact location of the Tc -point see drawing below.
Drawings
PLVG1-Bar-590-8x0-132x48-DC
PLVG1-Bar-845-8x0-200x48-DC
PrevaLED Bar Value, April 2014
page 2 of 4
PLVG1-Bar-1100-8x0-280x48-DC
PLVG1-Bar-2200-8x0-560x48-DC
All dimensions:
General tolerances:
mm
+/-0.15 if not specified
Safety Information

The LED module itself and all its components must not be mechanically stressed.

When handling the module without use of mountain screws avoid excessive force on the cover as it may be separated from the PCB.

The integrated mounting and locking mechanism on the cover of the module is intended to center and lock a reflector. Excessive
force on this mechanism may cause permanent damage to the module.
The modules are intended for operation only with matching OPTOTRONIC® of OTp series.
To also ease the luminaire/installation approval, electronic control gear for LED or LED modules should carry the CE mark and be
ENEC certified. In Europe the declarations of conformity must include the following standards:
CE: EC 61347-2-13, EN 55015, IEC 61547 and IEC 61000-3-2 - ENEC: 61347-2-13 and IEC/EN 62384.
Also check for the mark of an independent authorized certification institute.
Please see the relevant brochure for more detailed information (see "Related and Further Information")
OSRAM OPTOTRONIC® electronic control gear complies to all relevant standards and guarantees safe operation.

Installation of LED modules (with power supplies) needs to be made with regard to all applicable electrical and safety standards.
Only qualified personnel should be allowed to perform installations.

Pay attention to standard ESD precautions when installing the module.

Important information on photobiological safety is available in the application guide.

Eye Security EN 62471, Risk Group 1

Max. voltage U-OUT = 60V
Assembly Information

For optimum cooling a thermally conducting layer should be applied between module and heat sink.

Further details and recommendation for mounting can be found in the application guide.
PrevaLED Bar Value, April 2014
page 3 of 4
Ordering codes
Product group
Product name
PrevaLED Bar Value
PrevaLED Bar Value
PrevaLED Bar Value
PrevaLED Bar Value
PrevaLED Bar Value
PrevaLED Bar Value
PrevaLED Bar Value
PrevaLED Bar Value
*) EAN: reservation
PLVG1-Bar-590-830-132x48-DC
PLVG1-Bar-590-840-132x48-DC
PLVG1-Bar-845-830-200x48-DC
PLVG1-Bar-845-840-200x48-DC
PLVG1-Bar-1100-830-280x48-DC
PLVG1-Bar-1100-840-280x48-DC
PLVG1-Bar-2200-830-560x48-DC
PLVG1-Bar-2200-840-560x48-DC
EAN *
S-Unit *
4052899 134065
4052899 134126
4052899 134188
4052899 134287
4052899 133822
4052899 133884
4052899 133945
4052899 134003
40 x 1
40 x 1
40 x 1
40 x 1
40 x 1
40 x 1
40 x 1
40 x 1
S-Unit: products per shipping unit (subject to change)
Note: Typical performance data are subject to change without any further notice, particularly as LED technology evolves.
Sales and Technical Support
OSRAM GmbH
Marcel-Breuer-Straße 6
D-80807 München
Germany
Sales and technical support is given by the
local OSRAM subsidiaries.
On our world wide homepage all OSRAM
subsidiaries are listed with complete
address and phone numbers.
www.osram.com
+49 89 6213-0
Related and Further Information

PrevaLED® Application Guide
www.osram.com/prevaled-linear

OPTOTRONIC® Technical Guide
www.osram.com/ecg-downloads

OPTOTRONIC® Data Sheets
http://catalog.myosram.com
PrevaLED Bar Value, April 2014
page 4 of 4