Dual energy X-ray line scan camera C10800 series Dual Energy X-ray Line Scan Camera C10800 Series is a new high-speed and high-resolution dual energy X-ray line scan camera that can be used to effectively differentiate materials in a variety of nondestructive testing applications. Using the commercial frame grabber board, the 12-bit digital output enables easy connection to a computer or other external instrument. Acquired image processing, data processing and filing can be performed, allowing the configuration of any system. The 12-bit digital output provides high resolution and high contrast image with a wide dynamic range. By using a variety of combinations of scintillator, filter and gain factor, it is possible to optimize for different object and X-ray conditions in order to cover a wide range of applications from high energy range applications such as mineral resources sorting to middle or low energy applications such as drug detection, meat inspection, foods inspection. FEATURES Extract a target material from multi-energy image data Optimized for middle X-ray energy range (50 kV to 110 kV) or high X-ray energy range (100 kV to160 kV) * 12-bit digital output High resolution and a wide dynamic range Very good energy separation accuracy with well aligned dual energy images APPLICATIONS X-ray source Middle X-ray energy range : C10800-04ECM,-08FCM (50 kV to 110 kV) High X-ray energy range : C10800-04ECH (100 kV to 160 kV) C10800-04ECM C10800-08FCM C10800-04ECH 40 70 80 90 100 110 120 130 140 150 160 170 180 (kV) Security (high X-ray energy range) bone Example of separation of fat and bone in meat Example of model gun detection in briefcase Acquire high energy image and low energy image by a single scanning by Dual energy X-ray line scan camera, and then extract a target material by applying image processing to two images. Two images acquisition A sugar B salt Conveyor 60 fat Example of different materials separation Object 50 Food inspection (middle X-ray energy range) Food inspection with high accuracy Composite material inspection or sorting Drug detection, Medicine quality control Security check Mineral resources sorting - Rare metals detection Waste sorting for recycling OPERATING PRINCIPLE * Effective X-ray tube voltage range A B Target material information abstraction Image processing Low energy image High energy image A" B" (with correction) Subtraction A" B'xA" A' Subtracted image Abstract "B" information Low energy image High energy image A' B' A" B" salt sugar salt sugar salt (A"/A') Correct A' intensity to be equivalent to A" intensity Dual energy X-ray line scan camera Intensity in high energy image and low energy image appears differently because every material has different X-ray transmittance efficiency. Depending on the ratio between them, adjust intensity level and then subtract unnecessary part to extract a target material information. SPECIFICATIONS C10800-04ECM C10800-04ECH Scintillator method Approx. 50 kV to 110 kV Approx. 100 kV to 160 kV 0.8 mm 409.6 mm (Possible to change upon request) 1/512 1024 Type number Detection method Recommended use range Sensor element pitch Detection width Resolution Effective number of pixels *1 Approx. 50 kV to 110 kV 0.4 mm 1/1024 2048 (Lower energy image: 1st to 1024th, Higher energy image: 1025th to 2048th) (Lower energy image: 1st to 512th, Higher energy image: 513th to 1024th) Line speed A/D conversion Digital interface External control Correction functions C10800-08FCM 4 m/min to 100 m/min 12 bit RS-422 (Standard) RS-232C Analog processing : dark correction (offset) Digital processing : dark correction (offset), sensitivity correction Yes (option) 0 ˚C to +40 ˚C -10 ˚C to +50 ˚C 30 % to 80 % (no condensation) DC + 5 V 8 m/min to 200 m/min Multi analog gain control feature Ambient operating temperature Ambient storage temperature Ambient operating humidity Power supply Please contact Hamamatsu for various options, other detection width, other Sensor element pitch, other Effective X-ray tube voltage range. *1 Acquired image data is output with the following format. SYSTEM CONFIGURATION EXAMPLE C10800-04ECM / C10800-04ECH ( C10800-08FCM ) Time 1 512 (1024) X-ray source 1024 (2048) LOW energy HIGH energy image data image data Standard Option Pixel Dual energy X-ray line scan camera Shield box Object Computer Belt conveyor OPTIONS Power supply unit A8206-21 Power supply unit: A8206-21 Power cable 5 m: A9348-05 Software API Support (Microsoft Windows) - DCAM-API (http://www.dcamapi.com) DIMENSIONAL OUTLINES (Unit : mm) 147 32.5 11 ±0.5 48.8 228 ±0.5 250 ±0.5 50 47.5 37 200 240 *Irradiation allowance area 270±0.5 302.2 2-M4 D=6 16.1 (Sensor Position) 125 A8206-21 (option) (Approx. 2.0 kg) 50 ±0.5 66 (Sensor Position) 495 ±0.5 409.6 (Effective area) 200 Frame grabber board (installed into a computer) Note • The Dual energy X-ray line scan camera consists of only a sensor head. The image display equipment (computer and frame grabber board) and the X-ray source, etc. should be ordered separately. • The power supply unit is also optional. C10800-04ECM / C10800-04ECH / C10800-08FCM (Approx. 13.5 kg) 6 - φ 4.5 Data transfer cable Power cable 5 m A9348-05 *Align the X-ray beam to avoid irradiation except to the irradiation allowance area. ★ Product and software package names noted in this documentation are trademarks or registered trademarks of their respective manufacturers. ● ● Subject to local technical requirements and regulations, availability of products included in this promotional material may vary. Please consult your local sales representative. Information furnished by HAMAMATSU is believed to be reliable. However, no responsibility is assumed for possible inaccuracies or omissions. Specifications and external appearance are subject to change without notice.. © 2015 Hamamatsu Photonics K.K. HAMAMATSU PHOTONICS K.K. www.hamamatsu.com HAMAMATSU PHOTONICS K.K., Systems Division 812 Joko-cho, Higashi-ku, Hamamatsu City, 431-3196, Japan, Telephone: (81)53-431-0124, Fax: (81)53-435-1574, E-mail: [email protected] U.S.A.: Hamamatsu Corporation: 360 Foothill Road, Bridgewater, N.J 08807, U.S.A., Telephone: (1)908-231-0960, Fax: (1)908-231-1218 E-mail: [email protected] Germany: Hamamatsu Photonics Deutschland GmbH.: Arzbergerstr. 10, D-82211 Herrsching am Ammersee, Germany, Telephone: (49)8152-375-0, Fax: (49)8152-265-8 E-mail: [email protected] France: Hamamatsu Photonics France S.A.R.L.: 19, Rue du Saule Trapu, Parc du Moulin de Massy, 91882 Massy Cedex, France, Telephone: (33)1 69 53 71 00, Fax: (33)1 69 53 71 10 E-mail: [email protected] United Kingdom: Hamamatsu Photonics UK Limited: 2 Howard Court,10 Tewin Road, Welwyn Garden City, Hertfordshire AL7 1BW, UK, Telephone: (44)1707-294888, Fax: (44)1707-325777 E-mail: [email protected] North Europe: Hamamatsu Photonics Norden AB: Torshamnsgatan 35 16440 Kista, Sweden, Telephone: (46)8-509-031-00, Fax: (46)8-509-031-01 E-mail: [email protected] Italy: Hamamatsu Photonics Italia S.r.l.: Strada della Moia, 1 int. 6 20020 Arese (Milano), Italy, Telephone: (39)02-93581733, Fax: (39)02-93581741 E-mail: [email protected] China: Hamamatsu Photonics (China) Co., Ltd.: B1201 Jiaming Center, No.27 Dongsanhuan Beilu, Chaoyang District, Beijing 100020, China, Telephone: (86)10-6586-6006, Fax: (86)10-6586-2866 E-mail: [email protected] Cat. No. SFAS0023E07 MAR/2015 HPK Created in Japan