Catalog

Dual energy X-ray line scan camera
C10800 series
Dual Energy X-ray Line Scan Camera
C10800 Series is a new high-speed and high-resolution dual energy
X-ray line scan camera that can be used to effectively differentiate
materials in a variety of nondestructive testing applications.
Using the commercial frame grabber board, the 12-bit digital output
enables easy connection to a computer or other external instrument.
Acquired image processing, data processing and filing can be
performed, allowing the configuration of any system. The 12-bit
digital output provides high resolution and high contrast image with a
wide dynamic range.
By using a variety of combinations of scintillator, filter and gain
factor, it is possible to optimize for different object and X-ray
conditions in order to cover a wide range of applications from high
energy range applications such as mineral resources sorting to
middle or low energy applications such as drug detection, meat
inspection, foods inspection.
FEATURES
Extract a target material from
multi-energy image data
Optimized for middle X-ray energy range (50 kV to 110 kV)
or high X-ray energy range (100 kV to160 kV) *
12-bit digital output
High resolution and a wide dynamic range
Very good energy separation accuracy with
well aligned dual energy images
APPLICATIONS
X-ray
source
Middle X-ray energy range : C10800-04ECM,-08FCM (50 kV to 110 kV)
High X-ray energy range : C10800-04ECH (100 kV to 160 kV)
C10800-04ECM
C10800-08FCM
C10800-04ECH
40
70
80
90 100 110 120 130 140 150 160 170 180 (kV)
Security
(high X-ray energy range)
bone
Example of separation of fat and bone in meat
Example of model gun detection in briefcase
Acquire high energy image and low energy image by a single scanning by
Dual energy X-ray line scan camera, and then extract a target material by applying
image processing to two images.
Two images acquisition
A sugar
B salt
Conveyor
60
fat
Example of different materials separation
Object
50
Food inspection (middle X-ray energy range)
Food inspection with high accuracy
Composite material inspection or sorting
Drug detection, Medicine quality control
Security check
Mineral resources sorting - Rare metals detection
Waste sorting for recycling
OPERATING PRINCIPLE
* Effective X-ray tube voltage range
A
B
Target material information
abstraction
Image processing
Low energy image
High energy image
A"
B"
(with correction)
Subtraction
A"
B'xA"
A'
Subtracted image
Abstract "B"
information
Low energy image High energy image
A'
B'
A"
B"
salt
sugar
salt
sugar
salt
(A"/A')
Correct A' intensity to be equivalent to A" intensity
Dual energy X-ray
line scan camera
Intensity in high energy image and low energy image appears differently because every material has different X-ray transmittance
efficiency. Depending on the ratio between them, adjust intensity level and then subtract unnecessary part to extract a target
material information.
SPECIFICATIONS
C10800-04ECM
C10800-04ECH
Scintillator method
Approx. 50 kV to 110 kV
Approx. 100 kV to 160 kV
0.8 mm
409.6 mm (Possible to change upon request)
1/512
1024
Type number
Detection method
Recommended use range
Sensor element pitch
Detection width
Resolution
Effective number of pixels *1
Approx. 50 kV to 110 kV
0.4 mm
1/1024
2048
(Lower energy image: 1st to 1024th, Higher energy image: 1025th to 2048th)
(Lower energy image: 1st to 512th, Higher energy image: 513th to 1024th)
Line speed
A/D conversion
Digital interface
External control
Correction functions
C10800-08FCM
4 m/min to 100 m/min
12 bit
RS-422 (Standard)
RS-232C
Analog processing : dark correction (offset)
Digital processing : dark correction (offset), sensitivity correction
Yes (option)
0 ˚C to +40 ˚C
-10 ˚C to +50 ˚C
30 % to 80 % (no condensation)
DC + 5 V
8 m/min to 200 m/min
Multi analog gain control feature
Ambient operating temperature
Ambient storage temperature
Ambient operating humidity
Power supply
Please contact Hamamatsu for various options, other detection width, other Sensor element pitch, other Effective X-ray tube voltage range.
*1 Acquired image data is output with the following format.
SYSTEM CONFIGURATION EXAMPLE
C10800-04ECM / C10800-04ECH ( C10800-08FCM )
Time
1
512 (1024)
X-ray source
1024 (2048)
LOW energy
HIGH energy
image data
image data
Standard
Option
Pixel
Dual energy X-ray
line scan camera
Shield box
Object
Computer
Belt conveyor
OPTIONS
Power supply unit
A8206-21
Power supply unit: A8206-21
Power cable 5 m: A9348-05
Software API Support (Microsoft Windows)
- DCAM-API (http://www.dcamapi.com)
DIMENSIONAL OUTLINES
(Unit : mm)
147
32.5
11 ±0.5
48.8
228 ±0.5
250 ±0.5
50
47.5
37
200
240
*Irradiation allowance area
270±0.5
302.2
2-M4 D=6
16.1
(Sensor Position)
125
A8206-21 (option) (Approx. 2.0 kg)
50 ±0.5
66
(Sensor Position)
495 ±0.5
409.6 (Effective area)
200
Frame grabber board
(installed into a computer)
Note
• The Dual energy X-ray line scan camera consists of only a sensor head. The image display equipment
(computer and frame grabber board) and the X-ray source, etc. should be ordered separately.
• The power supply unit is also optional.
C10800-04ECM / C10800-04ECH / C10800-08FCM (Approx. 13.5 kg)
6 - φ 4.5
Data transfer cable
Power cable 5 m
A9348-05
*Align the X-ray beam to avoid irradiation except to the irradiation allowance area.
★ Product and software package names noted in this documentation are trademarks or registered trademarks of their respective manufacturers.
●
●
Subject to local technical requirements and regulations, availability of products included in this promotional material may vary. Please consult your local sales representative.
Information furnished by HAMAMATSU is believed to be reliable. However, no responsibility is assumed for possible inaccuracies or omissions.
Specifications and external appearance are subject to change without notice..
© 2015 Hamamatsu Photonics K.K.
HAMAMATSU PHOTONICS K.K.
www.hamamatsu.com
HAMAMATSU PHOTONICS K.K., Systems Division
812 Joko-cho, Higashi-ku, Hamamatsu City, 431-3196, Japan, Telephone: (81)53-431-0124, Fax: (81)53-435-1574, E-mail: [email protected]
U.S.A.: Hamamatsu Corporation: 360 Foothill Road, Bridgewater, N.J 08807, U.S.A., Telephone: (1)908-231-0960, Fax: (1)908-231-1218 E-mail: [email protected]
Germany: Hamamatsu Photonics Deutschland GmbH.: Arzbergerstr. 10, D-82211 Herrsching am Ammersee, Germany, Telephone: (49)8152-375-0, Fax: (49)8152-265-8 E-mail: [email protected]
France: Hamamatsu Photonics France S.A.R.L.: 19, Rue du Saule Trapu, Parc du Moulin de Massy, 91882 Massy Cedex, France, Telephone: (33)1 69 53 71 00, Fax: (33)1 69 53 71 10 E-mail: [email protected]
United Kingdom: Hamamatsu Photonics UK Limited: 2 Howard Court,10 Tewin Road, Welwyn Garden City, Hertfordshire AL7 1BW, UK, Telephone: (44)1707-294888, Fax: (44)1707-325777 E-mail: [email protected]
North Europe: Hamamatsu Photonics Norden AB: Torshamnsgatan 35 16440 Kista, Sweden, Telephone: (46)8-509-031-00, Fax: (46)8-509-031-01 E-mail: [email protected]
Italy: Hamamatsu Photonics Italia S.r.l.: Strada della Moia, 1 int. 6 20020 Arese (Milano), Italy, Telephone: (39)02-93581733, Fax: (39)02-93581741 E-mail: [email protected]
China: Hamamatsu Photonics (China) Co., Ltd.: B1201 Jiaming Center, No.27 Dongsanhuan Beilu, Chaoyang District, Beijing 100020, China, Telephone: (86)10-6586-6006, Fax: (86)10-6586-2866 E-mail: [email protected]
Cat. No. SFAS0023E07
MAR/2015 HPK
Created in Japan