XENON LAMPS / MERCURY XENON LAMPS

Super-Quiet Xenon Lamp
Super-Quiet Mercury-Xenon Lamp
OVERVIEW
FEATURES
●Super-Quiet Xenon Lamp
These are lamps filled with xenon gas that emits "white light" at a
high color temperature of 6000 K, which is close to that of sunlight
and covers a broad continuous spectrum from the ultraviolet to
infrared region (185 nm to 2000 nm). These xenon lamps are ideal as
light sources for various types of photometric instruments such as
spectrophotometers.
102
TLSXB0138EC
102
150 W SUPER-QUIET
XENON LAMP (L2273)
101
101
100
100
10-1
10-1
SOLAR RADIATION
ON SEA SURFACE
(AT ZERO METERS
ABOVE SEA LEVEL)
10-2
10-3
200
400
600
800
10-2
1000
1200
1400
1600
1800
10-3
2000
SOLAR IRRADIANCE ON SEA SURFACE (mW·cm-2·nm-1)
XENON LAMP IRRADIANCE (µW·cm-2 ·nm-1) at 50 cm
Irradiance
●No arc point shift
●High stability
Xenon lamp:
Fluctuation (p-p) 0.2 % Typ.
1.0 % Max.
Drift
±0.5 %/h Typ.
Mercury-xenon lamp:
Fluctuation (p-p) 0.5 % Typ.
2.0 % Max.
Drift
±0.5 %/h Typ.
●Long life
●Wide lamp lineup starting from low wattage input
●High intensity point light source
●High color temperature: 6000 K (Super-quiet xenon lamp)
●High UV intensity (Super-quiet mercury-xenon lamp)
WAVELENGTH (nm)
●Super-Quiet Mercury-Xenon Lamp
Mercury-xenon lamps produce high radiant energy especially in the
ultraviolet region due to an optimal mixture of mercury and xenon
gas. These lamps possess features of both xenon gas and mercury
discharge lamps. The spectral distribution includes a continuous
spectrum ranging from ultraviolet to infrared of the xenon gas and
strong mercury line spectra in the ultraviolet to visible region.
Compared to xenon lamps, the radiant spectrum in the ultraviolet
region of mercury-xenon lamps is sharper in width and its peak is
higher in intensity. These features make mercury-xenon lamps ideal
as ultraviolet light sources.
Irradiance
IRRADIANCE (µW·cm-2 ·nm-1) at 50 cm
103
TLSXB0139EC
102
150 W SUPER-QUIET
XENON LAMP (L2273)
100
200 W SUPER-QUIET
MERCURY-XENON LAMP (L2423)
10-1
HALOGEN LAMP (24 V-150 W)
10-2
300
400
500
600
700
800
900
1000
WAVELENGTH (nm)
103
IRRADIANCE (µW·cm-2 ·nm-1) at 50 cm
●Super-Quiet Xenon Lamp
• Spectrophotometer
• Liquid chromatograph
• Fluorospectrophotometer
• Microscope Light Source
• Color analyzer, color scanner
• Solar simulator, etc.
101
10-3
200
TLSXB0140EB
200 W SUPWE-QUIET
MERCURY-XENON LAMP (L2423)
102
101
100
30 W DEUTERIUM LAMP
10-1
10-2
10-3
200
300
WAVELENGTH (nm)
2
APPLICATIONS
400
●Super-Quiet Mercury-Xenon Lamp
• Wafer inspection system
• Semiconductor photolithographic equipment
• Fluorescent microscopy
• Blood analyzer
• UV irradiation equipment, etc.
ARC "INSTABILITY (FLUCTUATION)" and "SHIFT"
Light source lamps used for high precision photometry must have
good arc stability. However, cathodes used in conventional lamps
have two shortcomings in terms of arc stability. One problem is that
the arc emission point shifts intermittently due to inadequate electron
emission from the cathode. The other problem is that the arc point
shifts a little at a time due to the cathode tip wear that occurs with
operating time as the lamp ages.
Hamamatsu super-quiet lamps employ a high performance "BI
(Barium-Impregnated) cathode" developed totally in-house that
eliminates the above problems to deliver extremely high stability. This
durable cathode exhibits no wear at the cathode tip over operating time
and the arc point does not shift. So there is no need to realign the optical
system until the time finally comes when the lamp must be replaced.
Figure 3: Comparison of Cathode Tip Wear
Figure 1: "Fluctuation vs. Operating Time"
Measurement Block Diagram
Conventional cathode
Initial operation (after 5 hours)
HAMAMATSU High performance "BI(Barium-Impregnated) cathode"
Initial operation (after 5 hours) After 1000 hours of operation
Anode
Cathode
TLSXF0048
SQ XENON LAMP
SQ MERCURY-XENON LAMP
WINDOW 20 mm
ND FILTER
After 1000 hours of operation
Anode
APERTURE 5 mm
AMPLIFIER
SILICON PHOTODIODE
(S1226)
POWER SUPPLY
PC
Cathode
TLSXC0050ED
TLSXF0049
150 W Super-Quiet Xenon Lamp L2273
200 W Super-Quiet Mercury-Xenon Lamp L2423
a) Initial operation (after 5 hours)
a) Initial operation (after 5 hours)
1%
1%
Figure 2: Fluctuation vs. Operating Time
2 min.
2 min.
b) After 1000 hours of operation
1%
1%
b) After 1000 hours of operation
1%
2 min.
c) After 2000 hours of operation
1%
2 min.
c) After 2000 hours of operation
2 min.
2 min.
TLSXB0129EA
1%
d) After 3000 hours of operation
2 min.
TLSXB0128EA
3
STRUCTURE AND OPERATION
These lamps have an oval bulb made of quartz glass (silica glass) in
which a cathode and an anode face each other. The bulb for superquiet xenon lamps is filled with high-purity, high-pressure xenon gas.
The bulb for super-quiet mercury-xenon lamps is filled with a mixture
of high-purity, high-pressure xenon gas and high-purity mercury.
The lamps emit light by arc discharge. The lamps are installed
vertically (or horizontally) with the anode at the upper side (some
types of lamps are only installed vertically) and operate on DC. When
the specified voltage is supplied across the anode and cathode, the
lamp immediately starts discharging to form an arc discharge.
After the lamp lights up, several minutes are required to reach the
maximum light output because the gas pressure inside the bulb
changes until it reaches thermal equilibrium.
During lamp operation, the bulb wall temperature rises above 500 °C
and the gas pressure inside the bulb increases to approximately 4
MPa which is 4 times higher than when the lamp is not operating.
CHARACTERISTICS
●Irradiance
Super-Quiet Xenon Lamp
The irradiance of xenon lamps is continuous over the ultraviolet,
visible and infrared regions. Some line spectra are emitted in the
visible to infrared regions.
Super-Quiet Mercury-Xenon Lamp
The irradiance of mercury-xenon lamps has strong line spectra from
the ultraviolet to the visible region. This radiation spectrum includes
both the radiation spectrum of xenon lamps and mercury line spectra.
Figure 5: Irradiance
Super-Quiet Xenon Lamp
102
ANODE
QUARTZ BULB
TLSXB0130EB
300 W (L2479)
IRRADIANCE (µW·cm-2 ·nm-1) at 50 cm
Figure 4: Lamp Structure
150 W (L2273)
101
100
10-1
75 W (L2174)
35 W (L2173)
10-2
10-3
200
CATHODE
400
600
[Super-quiet xenon lamp]
High-purity xenon gas
800
1000
1200
1400
1600
2000
WAVELENGTH (nm)
[Super-quiet mercury-xenon lamp]
High-purity xenon gas
+
High-purity mercury
Super-Quiet Mercury-Xenon Lamp
103
IRRADIANCE (µW·cm-2 ·nm-1) at 50 cm
TLSXC0047EA
TLSXB0131EB
500 W (L8288)
102
101
100
100 W (L2422)
10-1
200 W (2423)
10-2
10-3
200
300
400
500
600
700
WAVELENGTH (nm)
4
1800
800
900
1000
●Difference in Irradiance by Bulb Material
●Radiant Flux Distribution
The irradiance differs according to the bulb material. Fused silica
transmits light at wavelengths shorter than 240 nm, yet ozone-free
silica cuts off light of wavelengths shorter than 240 nm. Select the
bulb material that meets your application.
The lamps emit a radiant flux distribution uniformly along the
horizontal direction.
Figure 6: Irradiance Comparison of Different Bulb Materials
150 W Super-Quiet Xenon Lamp L2273
200 W Super-Quiet Mercury-Xenon Lamp L2423
Figure 8: Radiant Flux Distribution (Vertical Lighting)
150 W Super-Quiet Xenon Lamp
IRRADIANCE (µW·cm-2 ·nm-1) at 50 cm
101
TLSXB0009ED
FUSED SILICA L2273
100
ANODE
10-1
10-2
OZONE-FREE SILICA L2274
IRRADIANCE
(RELATIVE VALUE)
10-3
CATHODE
10-4
200
300
400
WAVELENGTH (nm)
●Light Output Intensity Contour Map
Maximum light output intensity is more intense around the cathode,
and decreases towards the anode.
Figure 7: Light Output Intensity Contour Map (Vertical Lightning)
150 W Super-Quiet Xenon Lamp L2273
ANODE
1
10
Figure 9: Lamp Current vs. Lamp Voltage
150 W Super-Quiet Xenon Lamp L2273
WAVELENGTH : 365 nm
LAMP CURRENT: 8.5 A
AMBIENT TEMP. : +25 °C
1
19
1.0
20
30
40
50
0
at +25 °C
TLSXB0132EA
20
1.5
0.5
●Lamp Current and Lamp Voltage
LAMP VOLTAGE (V dc)
DISTANCE FROM CATHODE
(mm)
2.0
TLSXC0007EA
60
70 80
90
18
17
16
RATED LAMP CURRENT
(RECOMMENDED: 8.5 A)
CATHODE
15
7.5
0
1.0
0.5
ARC WIDTH (mm)
8.0
1
10
20
WAVELENGTH : 365 nm
LAMP CURRENT: 8.0 A
AMBIENT TEMP. : +25 °C
30
1.0
40
50
60
70
0
24
23
22
80
90
CATHODE
0
1.0
0.5
ARC WIDTH (mm)
at +25 °C
TLSXB0086EC
26
25
1
1.5
0.5
9.5
200 W Super-Quiet Mercury-Xenon Lamp L2423
LAMP VOLTAGE (V dc)
DISTANCE FROM CATHODE
(mm)
2.0
9.0
LAMP CURRENT (A dc)
200 W Super-Quiet Mercury-Xenon Lamp L2423
ANODE
8.5
TLSXC0006EC
21
7.0
TLSXC0032ED
RATED LAMP CURRENT
(RECOMMENDED: 8.0 A)
7.5
8.0
8.5
9.0
LAMP CURRENT (A dc)
5
●Light Output Intensity and Lamp Current
●Light Output Intensity and Ambient Temperature
The light output intensity of a lamp is proportional to the lamp current.
The light output intensity of a lamp also varies with ambient
temperature. This is due to the change in light output intensity
resulting from the change in gas pressure with temperature.
The ambient temperature must be kept constant to ensure stable
lamp operation.
Figure 10: Light Output Intensity vs. Lamp Current
140
at +25 °C
TLSXB0133EA
Figure 12: Light Output Intensity vs. Ambient Temperature
150 W Super-Quiet Xenon Lamp L2273
120
DETECTOR: S1226
TLSXB0135EC
100
80
60
RATED LAMP CURRENT
(RECOMMENDED: 8.5 A)
0
7.5
8.0
8.5
9.0
9.5
LAMP CURRENT (A dc)
RELATIVE LIGHT OUTPUT INTENSITY (%)
RELATIVE LIGHT OUTPUT INTENSITY (%)
150 W Super-Quiet Xenon Lamp L2273
130
120
110
100
RECOMMENDED
OPERATING AMBIENT
TEMPERATURE
90
80
0
10
20
140
30
40
50
60
70
AMBIENT TEMPERATURE (°C)
at +25 °C
TLSXB0088EB
●Light Output Intensity and Operating Time
The light output intensity decreases over operating time. This is
because of a loss of glass transmittance caused by blacking of the
bulb wall due to evaporation of the cathode materials and solarization
effect of ultraviolet radiation.
120
100
Figure 13: Light Output Intensity vs. Operating Time
80
150 W Super-Quiet Xenon Lamp L2273
60
RATED LAMP CURRENT
(RECOMMENDED: 8.0 A)
0
7.0
7.5
8.0
8.5
9.0
LAMP CURRENT (A dc)
●Initial Stability of Light Output Intensity
After the lamp lights up, the light output intensity varies until the gas
pressure inside the bulb reaches thermal equilibrium. It takes several
minutes to reach the maximum light output.
RELATIVE LIGHT OUTPUT INTENSITY (%)
RELATIVE LIGHT OUTPUT INTENSITY (%)
200 W Super-Quiet Mercury-Xenon Lamp L2423
120
LAMP CURRENT: 8.5 A dc
DETECTOR: S1226
at +25 °C
TLSXB0136EC
100
80
60
40
20
0
0
Figure 11: Initial Stability of Light Output Intensity
500
1000
1500
2000
2500
3000
OPERATING TIME (h)
DETECTOR: S1226
at +25 °C
200 W Super-Quiet Mercury-Xenon Lamp L2423
LAMP CURRENT: 8.0 A dc
WAVELENGTH: 365 nm
at +25 °C
TLSXB0087EC
100
80
60
150 W SUPER-QUIET XENON LAMP L2273
40
200 W SUPER-QUIET MERCURY-XENON LAMP L2423
20
0
0
5
10
15
20
OPERATING TIME (min)
25
30
RELATIVE LIGHT OUTPUT INTENSITY (%)
RELATIVE LIGHT OUTPUT INTENSITY (%)
TLSXB0134EB
120
100
80
60
40
20
0
0
200
400
600
800
1000 1200 1400 1600 1800 2000
OPERATING TIME (h)
6
POWER SUPPLY
Lamps used as a light source for photometric applications must
provide stable light output. To ensure stable lamp operation, the
power supply must also provide high stability equal to or better than
that of the lamp.
Figure 14: Block Diagram of Regulated Power Supply
SQ XENON LAMP
SQ MERCURY-XENON LAMP
STARTER
TRIGGER TRIGGER
TRANSFORMER
SWITCH
AC
INPUT
CONSTANT DC CURRENT POWER
SUPPLY
MAIN POWER
SUPPLY
ANODE
CATHODE
TLSXC0048EB
●Main Power Supply
Besides supplying the lamp with stable DC power, the main power
supply gives the cathode an optimal operating temperature at a
specified current. The cathode temperature is very important for lamp
operation. A cathode temperature that is too high speeds up the
evaporation of cathode materials. Too low of a temperature will
increase the load on the cathode, causing unstable electron emission
and greatly reducing the lamp service life.
The lamp current must be set within the specified range to operate
the lamp stably over long periods of time. For this reason, the
operating current value and its range are specified for each lamp
type.
●Starter
The starter is for starting lamp discharge. It applies a high-frequency
pulse to the lamp load by inductive coupling. (See Figure 14.) In the
initial stage of lamp operation, the discharge starts at approximately
10 kV. However, this characteristic varies according to the drop in
electron emission capability of the cathode or variations in the fill gas
pressure.
In actual equipment operation, a trigger voltage of 20 kV to 30 kV
should be applied to the lamp, while taking an ample safety margin
into account.
7
SPECIFICATIONS
SUPER-QUIET XENON LAMP
Type No.
L2173
L2193
L2174
L2174-01
L2174-02
L2194
L2194-01
L2194-02
L2194-11
L10725
L10725-01
L10725-02
L10726
L10726-01
L10726-02
L11307
L11307-01
L9289
L9289-01
L2175
L2195
L2273
L2274
L11033
L11034
L2479
L2480
Lamp
Rating
Arc
Length
Lamp
Current
Lamp
Voltage
Window Material
(Transmission Wavelength)
(W)
(mm)
(A dc)
(V dc)
35
1.0
3.5±0.2
11
(nm)
Fused Silica (185 to 2000)
Ozone-free Silica (240 to 2000)
Light Output Stability
Fluctuation
Drift
(p-p)
Typ.
Max.
(%/h)
(%)
±0.5
1.0
±0.5
1.0
±0.5
1.0
±0.5
1.0
±0.5
1.0
±0.5
1.0
Fused Silica (185 to 2000)
75
1.3
5.4±0.5
15
Ozone-free Silica (240 to 2000)
13
1.0
Fused Silica (185 to 2000)
75
1.0
5.7±0.3
13.5
Ozone-free Silica (240 to 2000)
Fused Silica (185 to 2000)
100
1.3
7.0±0.5
15
Ozone-free Silica (240 to 2000)
2.5
7.5±0.5
19
2.0
8.5±0.5
17
3.0
15.0±1.0
20
150
300
Fused Silica (185 to 2000)
Ozone-free Silica (240 to 2000)
Fused Silica (185 to 2000)
Ozone-free Silica (240 to 2000)
Fused Silica (185 to 2000)
Ozone-free Silica (240 to 2000)
Fused Silica (185 to 2000)
Ozone-free Silica (240 to 2000)
SUPER-QUIET MERCURY-XENON LAMP
Type No.
L2421
L2481
L2481-01
L2481-02
L2422
L2422-01
L2422-02
L7046
L8029
L8029-01
L2482
L7047
L2423
L2570
L8706
L2483
L2917
L8288
Lamp
Rating
Arc
Length
Lamp
Current
Lamp
Voltage
Window Material
(Transmission Wavelength)
(W)
50
(mm)
1.0
(A dc)
3.5±0.2
(V dc)
14
(nm)
Fused Silica (185 to 2000)
75
1.0
5.4±0.5
14
Fused Silica (185 to 2000)
±0.5
2.0
±0.5
2.0
±0.5
2.0
±0.5
2.0
±0.5
3.0
±0.5
2.0
±0.5
2.0
Fused Silica (185 to 2000)
1.3
5.5±0.5
100
Light Output Stability
Fluctuation
Drift
(p-p)
Typ.
Max.
(%/h)
(%)
±0.5
2.0
18
Ozone-free Silica (240 to 2000)
Fused Silica (185 to 2000)
0.8
150
1.7
7.5±0.5
20
200
2.0
8.0±0.5
24
250
1.8
8.5±0.5
27
350
2.5
14.0±1.0
25
500
3.0
20.0±1.0
25
Fused Silica (185 to 2000)
Ozone-free Silica (240 to 2000)
Fused Silica (185 to 2000)
Ozone-free Silica (240 to 2000)
Fused Silica (185 to 2000)
Fused Silica (185 to 2000)
Ozone-free Silica (240 to 2000)
Fused Silica (185 to 2000)
NOTE: AThe life end is defined as the time when the light output intensity falls to 50 % of its initial value or when the output fluctuation (p-p) exceeds 1.0 %
for super-quiet xenon lamps and 2.0 % for super-quiet mercury-xenon lamps (3.0 % for 250 W type L8706).
BOpen-circuit voltage necessary for certain lighting of lamps.
CSee pages 10 and 11.
8
A
Guaranteed
Operation
Life
(h)
1000
B
Average
Life
(h)
2000
1000
2000
2000
3000
1500
2500
1200
2500
1800
3000
3000
4000
1000
2000
Orientation
(degree)
Vertical ±15 or
Horizontal ±15
Vertical ±15 or
Horizontal ±15
Vertical ±15 or
Horizontal ±15
Cooling
Method
Convection
Cooling
Convection
Cooling
Convection
Cooling
Supply
Voltage
Min.
(V dc)
Trigger
Voltage
(kV)
15
50
15
50
15
50
Vertical ±15 or
Horizontal ±15
Convection
Cooling
50
15
Vertical ±15 or
Horizontal ±15
Convection
Cooling
65
20
Vertical ±15 or
Horizontal ±15
Forced
Cooling
80
25
A
Guaranteed
Operation
Life
(h)
500
C
2
Average
Life
(h)
1000
Orientation
Cooling
Method
(degree)
Vertical ±15 or Horizontal ±15 Convection Cooling
Vertical ±15 or
Horizontal ±15
500
1000
500
1000
1000
2000
1000
2000
1000
2000
2000
3000
Vertical ±15 or
Horizontal ±15
Vertical ±15 or
Horizontal ±15
Vertical ±15
500
1000
Vertical ±15
1000
2000
Vertical ±15
Vertical ±15 or
Horizontal ±15
15
19
q
15
19
15
15
19
w
15
19
15
e
5
45
r,t
7
68
y,u
C
Trigger
Voltage
(kV)
15
D
Applicable
DimenPower Supply
Weight
sional
+
Starter
Outline
+
Lamp Housing
(g)
1
10
2
14
3
4
18
2
15
q
3
4
19
2
15
3
Convection
Cooling
50
15
Convection
Cooling
50
15
65
20
5
43
65
20
5
45
65
20
6
62
—E
70
25
7
68
y,u
80
30
7
80
y,u
Vertical ±15
Convection
Cooling
Convection
Cooling
Forced Cooling
Forced
Cooling
Forced Cooling
Type No.
L2173
L2193
L2174
L2174-01
L2174-02
L2194
L2194-01
L2194-02
L2194-11
L10725
L10725-01
L10725-02
L10726
L10726-01
L10726-02
L11307
L11307-01
L9289
L9289-01
L2175
L2195
L2273
L2274
L11033
L11034
L2479
L2480
14
2
3
4
2
3
4
3
2
3
4
2
3
4
2
3
2
3
B
Supply
Voltage
Min.
(V dc)
50
D
Applicable
DimenPower Supply
sional Weight
+
Starter
Outline
+
Lamp Housing
(g)
r,t
Type No.
L2421
L2481
L2481-01
L2481-02
L2422
L2422-01
L2422-02
L7046
L8029
L8029-01
L2482
L7047
L2423
L2570
L8706
L2483
L2917
L8288
NOTE: DPower supplies should be used in combination with a starter (sold separately) or lamp housing.
EPlease consult us.
9
DIMENSIONAL OUTLINES (Unit: mm)
1 Super-Quiet Mercury-Xenon Lamp: L2421
2
Super-Quiet Xenon Lamp: L2173, L2193, L2174, L2194,
L10725, L10726, L11307, L9289
Super-Quiet Mercury-Xenon Lamp: L2481, L2422, L7046
2
13
11
2
UP
UP
7.5
9
14 (L2173, L2193: 12)
9
11
13
7.5
37.0 ± 0.5
(L10725, L10726: 36.85 ± 0.50)
82
90 MAX.
37.0 ± 0.5
82
90 MAX.
12
2
2
METAL BASE
METAL BASE
TLSXA0045ED
Super-Quiet Xenon Lamp: L2174-01, L2194-01/-11,
L10725-01, L10726-01, L11307-01, L9289-01
Super-Quiet Mercury-Xenon Lamp: L2481-01, L2422-01, L8029/-01
4
Super-Quiet Xenon Lamp: L2174-02, L2194-02,
L10725-02, L10726-02
Super-Quiet Mercury-Xenon Lamp: L2481-02, L2422-02
M2.3
11
7.5
2
13
9
14
9
13
90 MAX.
82
14
UP
82
9
95 MAX.
UP
37.0 ± 0.5
(L8029, L8029-01: 36.75 ± 0.50)
(L2194-11, L10725-01, L10726-01: 36.85 ± 0.50)
13
2
37.0 ± 0.5
(L10725-02, L10726-02: 36.85 ± 0.50)
3
TLSXA0101EB
METAL BASE
METAL BASE
M2.3
TLSXA0102EB
10
TLSXA0007EE
5
Super-Quiet Xenon Lamp: L2175, L2195, L2273, L2274,
L11033, L11034
Super-Quiet Mercury-Xenon Lamp: L2482, L7047, L2423, L2570
6 Super-Quiet Mercury-Xenon Lamp: L8706
M5
20
15
M4
UP
UP
12
13
20
20
57.9 ± 0.5
125
13
15
12
58.0 ± 0.5
153 MAX.
150 MAX.
125
20 (L2482, L7047: 18)
METAL BASE
METAL BASE
M4
M5
TLSXA0103EA
Applicable Power Supply +
Starter + Lamp Housing
Combination
Super-Quiet Xenon Lamp: L2479, L2480
Super-Quiet Mercury-Xenon Lamp: L2483, L2917, L8288
A
M5
20
Applicable Power
Applicable A Applicable Lamp
Supply Type No. Starter Type No. Housing Type No.
UP
13
150
26 (L8288: 29)
q
C8848
w
C8848-00-57
e
C8849-00-70
r
C4251
E2419 Series B
C8849
—
E7536 Series C
t
C8849
C4251
E2420
y
C11320
—
E10180 Series C
u
C11320
C4339
E5421
See also pages 9 and 12.
NOTE: AStarters are sold separately.
BTwo types of heatsink fins (7.5 mm and 9 mm diameter) are
available to match different lamp metal bases.
CHas an internal starter.
65.0 ± 0.5
(L8288: 70.0 ± 0.5)
13
20
175 MAX.
7
TLSXA0092EB
METAL BASE
M5
TLSXA0104EA
11
POWER SUPPLY
Lamps used as the light source for photometric applications must provide stable light
output. We recommend using Hamamatsu dedicated power supplies for lamp
operation. Using these dedicated power supplies allow extracting the full performance
from our super-quiet lamps.
Select the power supply that matches your application. We also provide OEM power
supplies, so please feel free to consult us.
Left: C8848, C8849
Right: Starter C4251 (Sold Separately)
Type No.
Control
Method
Suitable
Lamp
Rating
(W)
35 to 75
(Xenon)
50 to 100
(Mercury-Xenon)
C8848
35 to 75
(Xenon)
C8848-00-57
50 to 75
Switching (Mercury-Xenon)
Constant
Current 100 to 150
(Xenon)
C8849-00-70
200
(Mercury-Xenon)
C8849
C11320
150
(Xenon)
150 to 200
(Mercury-Xenon)
300
Dropper
(Xenon)
Constant
350, 500
Current
(Mercury-Xenon)
Power Supply
Discharge
Current Stability
A
(at 25 °C)
Suitable
Input
Drift Ripple
Lamp
Voltage
(p-p)
Current
Max. Max.
(A dc) (V ac) (%/h) (%)
Starter
B
Dimension
W×H×D
(mm)
C
Start
Weight
Method
B
NOTE
Dimension
Type No.
W×H×D
(mm)
(kg)
3.5 /
5.4 /
5.5
3.5 /
5.4 /
5.7
7.0 /
8.0 /
8.5
2.7
100
to
240
±0.1
E
144 × 90 × 282
CE marking C4251 100 × 60 × 89
compliance
D
Manual High stability
With time
21
counter
165 × 272 × 360
C4339 111 × 65 × 102
0.1
7.5 /
8.0 /
8.5
F
14 /
15 /
20
100
/ 115
/ 200
/ 230
E
NOTE: ASet the lamp current to the rated current by using the output current selector switch.
BExcluding projecting parts
CThere are 2 ways for triggering.
Manual : Turn "Lamp On" switch on after "Power" switch, then ignite lamp. This manual mode should be suitable laboratory experiments.
Auto : Simultaneously ignite lamp with "Power" switch on. Auto mode should be suitable for production line or intallation to an equipment.
DSelectable for auto mode
EPower supply must be used with a starter (sold separately). (See "Applicable Power Supply + Starter + Lamp Housing Combination" on page 11.)
FSetting at factory prior to shipment.
CAUTION: These power supplies use a trigger mode in which a positive high voltage is applied to the anode.
Use extreme caution concerning the insulation for the anode.
SET UP
POWER
SUPPLY
C8849
POWER
SUPPLY
C11320
12
LAMP
HOUSING
POWER
SUPPLY
E7536
C8848
C8849
LAMP
HOUSING
POWER
SUPPLY
STARTER
C11320
C4339
E10180
STARTER
C4251
LAMP
HOUSING
E2419
E2420
LAMP
HOUSING
E5421
LAMP HOUSING
Hamamatsu provides various lamp housings to make our lamps easier to use.
Besides using a stable power supply, it is also essential to use a proper lamp housing
to extract full performance from the lamps and obtain stable light output.
Four models of lamp housings are currently available. Among these, the E7536 and
E10180 are designed for high accuracy yet easier handling, while the E2419, E2420
and E5421 feature simplified designs.
The E7536 and E10180 have an internal reflecting mirror and light output lens to
provide a collimated light beam with high intensity. The built-in interlock function,
starter and cooling fan enhance safety, for example, the surface temperature on the
housing is kept below +40 °C during operation. The optical axis can be easily aligned
with the adjuster screws from the outside of the housing.
E7536
TLSXF0129
●DIMENSIONAL OUTLINES (Unit: mm)
E2419/-01 (For 35 W, 50 W, 75 W and 100 W Lamps)
E2420 (For 150 W and 200 W Lamps)
FRONT VIEW
COOLING FAN
SIDE VIEW
ANODE TERMINAL
ANODE METAL BASE/
COOLING FIN *
A
E7536/-01 (For 150 W and 200 W Lamps)
FRONT VIEW
SIDE VIEW
REMOVE THIS
COVER WHEN
REPLACING LAMP
A
FOCUS
LENS*
LAMP
20 FUSED
SILICA WINDOW
LAMP
77
60
D
280
B
30
M37 P=1
CATHODE METAL BASE/
COOLING FIN *
REFLECTING
MIRROR
140
12
CATHODE TERMINAL
E2419/-01
50
56
110 to 140
24
35
A
B
C
D
E
30
30
POWER
INPUT
CONNECTOR
E2420
65
95
90 to 120
43
42.5
50
10
50
C
E
30
Type No.
4- 4.3
Lamp Anode
Metal Base
9
12
78
4-W3/16
Plastic feet attached as standard features.
These can be removed to use their holes
for installation of lamp housing.
39
Lamp Cathode
Metal Base
9
7.5
12
39
An SMA fiber adapter (A11096) is available
as on accessory.
78
30
TLS A0002EA
E5421 (For 300 W, 350 W and 500 W Lamps)
E10180/-01 (For 300 W, 350 W and 500 W Lamps)
COOLING FAN
SIDE VIEW
ANODE
TERMINAL
30
FUSED SILICA
WINDOW
REMOVE THIS
COVER WHEN
REPLACING
LAMP
(BACK SIDE)
FOCUS
LENS*
M58 P=1
LAMP
210
275
SIDE VIEW
360
VENT
36
FRONT VIEW
CONNECTOR
FOR
COOLING FAN
REMOVE THIS
COVER WHEN
REPLACING LAMP
LAMP
100
FRONT VIEW
TLSXA0083ED
118
COOLING FAN
* E7536-01: It has a UV cut filter ( 68 mm)
instead of focus lenses.
60
Weight: Approx. 1.1 kg (E2419)
Approx. 1.2 kg (E2420)
E2419
E2419-01
E2420
5
Weight: Approx. 3.5 kg
60
*
100
BOTTOM VIEW
M4
BOTTOM VIEW
5
100
REFLECTING
MIRROR
62.5
17
POWER
INPUT
CONNECTOR
125
125
75
150
BOTTOM VIEW
Weight: Approx. 2.0 kg
BOTTOM VIEW
4-M3
10
CATHODE
TERMINAL
9
39
120
160
4
6
150
6
Weight: Approx. 5.5 kg
128
100
40
* E10180-01: It has a UV cut filter ( 90 mm)
instead of focus lenses.
4-M4
Plastic feet attached as standard features.
These can be removed to use their holes
for installation of lamp housing.
64
4-W3/16
Plastic feet attached as standard features.
These can be removed to use their holes
for installation of lamp housing.
40
100
128
TLSXA0105EC
TLS A0001EA
13
HANDLING PRECAUTION
(Be sure to read before using lamp)
●Installation Precautions
1. Always handle the lamp very carefully.
The lamp is filled with high pressure gas (approx. 1 MPa at room temperature and approx. 4 MPa during operation). Subjecting the lamp to
strong shocks or scratching the surface of the glass bulb might rupture the bulb, causing hazards from flying glass fragments.
When handling the lamp, always wear a protective mask, long-sleeved shirt and gloves for safety.
Keep the specified package that came supplied with the lamp, because it will be used for lamp replacement.
2. Never touch the silica glass bulb of the lamp with bare hands.
Operating the lamp with dust or grime still on the glass bulb causes it to thermally stick on the bulb and cuts the light transmittance. This results
in low light output intensity and also lowers the mechanical strength of the glass bulb. If dust or grime adheres to the bulb, gently wipe it off the
bulb using absorbent cotton or gauze moistened with high-quality alcohol and thoroughly wrung out. In such cases, use a proper protective
mask, shirt and gloves mentioned above and take care not to apply any strong shocks to the lamp.
3. Install the lamp in a correct direction and polarity. (See Figure 15.)
Operating the lamp while installed in the wrong direction or polarity will damage the cathode, leading to permanent lamp defects.
[Vertical lighting]
To install the lamp in an upright position, make sure that the "UP" or "+" mark (anode mark) scribed on the metal base is positioned facing
upwards.
[Horizontal lighting]
To install the lamp in a horizontal position, make sure that the sealed-off tip is positioned parallel to ground (horizontal plane). Use a magnet to
adjust the position of the arc point so that the discharge stays along the center line of both electrodes. To obtain adequate performance from the
lamp, it is essential to set the arc point at the correct position by using a proper magnet. (See Figure 16.)
Figure 15: Lamp Installation Direction and Polarity
<Vertical lighting>
<Horizontal lighting>
ANODE
(+)
ANODE
(+)
CATHODE
(-)
SEALED-OFF TIP
SEALED-OFF TIP
(This must always face sideways.)
CATHODE
(-)
Figure 16-1
TOP VIEW
SIDE VIEW
UP
N
N
MAGNET
S
35 W to 100 W
9.5 to 10.5
Unit: mm
TLSXC0011EB
S
Figure 16-2
5.0 ± 1.0
55.0 ± 1.0
150 W to 300 W 12.0 to 12.5
UP
MAGNET
Magnet
Position
Example
(Direction)
TDK
See
FB3G
38.0±1.0
Figure
D10 × 5S
10 mm dia.,
16-1
5 mm thickness
TDK
FB3G
See
55.0±1.0
D15 × 7S
Figure
15 mm dia.,
16-2
7 mm thickness
Power
Surface Magnetic Distance*
Consumption Flux Density (mT) (mm)
38.0 ± 1.0
N
S
N
(
)
(
)
* Distance from the center of arc to the surface of magnet.
Unit: mm
S
TLSXC0012EB
●Operating Precautions
4. Observe high voltage and high temperature precautions.
Lamps discharge starts by application of a high trigger voltage of 20 kV to 30 kV. Sufficient insulation must be installed to prevent electrical
shocks. When the lamp is used near equipment such as a PC (personal computer) which is vulnerable to noise, start the computer operation
after the lamp has already been turned on.
The lamp is extremely hot during operation and also immediately afterwards, so do not touch the lamp with bare hands and do not let the lamp
get close to flammable materials.
Never open the cover of the lamp housing during operation since the lamp is at an extremely high temperature.
If you have to open the cover, always use protective gear. (Refer to item 1.)
5. Observe ultraviolet radiation precautions
These lamps emit ultraviolet radiation which is harmful to the eyes and skin. Avoid looking directly at an operating lamp or exposing the skin
directly to it since there is danger of burns to the skin or eyes.
Always wear a light-shielding protector (ISO 4849 or equivalent standard) during lamp operation.
14
6. Always observe the rated values (specifications).
The rated operating current is specified for each lamp type. (See the specifications on pages 8 and 9.)
If used outside the specified rated range, operation will become unstable and the service life will be shortened drastically. Lamps of 250 W or
more require a fan for forced air cooling.
7. We recommend replacing the lamp by the guaranteed operation life. If using the lamp for longer than this
period, replace it when the total operating time exceeds the average life plus 500 hours (plus 300 hours for
500 W mercury-xenon lamps), or when the inner wall of the bulb becomes extremely dark.
When the total operating time exceeds the average life plus 500 hours (plus 300 hours for 500 W mercury-xenon lamps), vaporization and
spattering from the electrodes will adhere to the inner wall of the bulb, and speed up blackening of the bulb as well as disturbing heat
dissipation. If this lamp is used continuously, the temperature (pressure) inside the lamp bulb increases abnormally, possibly causing the lamp
to rupture or break.
●Precautions When Removing
8. Place the used lamp in the specified package that came supplied with the lamp.
When removing a used lamp from the lamp housing, be sure to wait until the lamp cools to room temperature and wear a protective mask, longsleeved shirt and gloves for safety.
High pressure gas still remains even inside a used lamp. Rough handling may cause the lamp to rupture, so handle the used lamp as carefully
as you would a new lamp.
9. Disposal of lamps
Lamps are filled with high pressure (approx. 1 MPa at room temperature) xenon gas (xenon gas and mercury in mercury-xenon lamps).
When disposing of the used lamp, take appropriate measures in compliance with applicable regulations regarding waste disposal and correctly
dispose of it yourself, or entrust disposal to a licensed industrial waste disposal company.
In any case, be sure to comply with the regulations in your country, state, region or province to ensure the used lamp is disposed of legally and
correctly.
●Caution Items When Designing Lamp Housings
A. The lamp housing must have a sturdy cover.
The lamp is filled with high pressure gas (approx. 1 MPa at room temperature and approx. 4 MPa during operation). Lamp housings must have a sturdy cover (enclosure) to avoid possible breakage.
Figure 17
B. Clamp the lamp only at one end of the lamp. Leave the other end unclamped.
(See Figure 17.)
The glass bulb expands from heat during operation. So if both metal base electrodes of the lamp are
clamped by holders made of a hard material or having a rigid, inflexible frame, the glass bulb may eventually rupture. Always clamp the lamp at one end to permit the lamp to absorb thermal expansion.
Leave the other end of the lamp unclamped. When designing the lamp housing, also be sure to note
the operating temperature at the metal bases of the lamp. (Refer to item D.)
C. Use caution when focusing the light, so that the lamp operating temperature
will not rise abnormally.
(+)
ANODE
COOLING FIN
Be careful to
avoid oxidation.
Clamp the lamp
only at one end.
Leave the other
end unclamped.
When focusing the light from the lamp with a mirror or other means, be sure not to focus it onto the bulb
wall or electrodes. Doing so increases the lamp operating temperature excessively.
Always be careful with the lamp operating temperature when using a condenser mirror. (See Item D.)
D. Use caution to avoid excessive temperature rise during operation. (See Figure 17.)
(–)
COOLING FIN
The lamp should be operated at less than 750 °C on the bulb surface and at less than 200 °C on the
metal base surface. If the lamp operating temperature exceeds these upper limits, "oxidation of elecCATHODE
trode leads" and "excessive wear on electrodes or consumption of enclosed gas" may occur, leading to
a significant reduction in lamp life. In addition, the pressure inside the lamp may rise abnormally, possiTLSXC0049EB
bly causing cracks or breakage in the glass portion around the leads. Allow for a safety margin for thermal heat emitted from the lamp housing and provide a structure or use materials that efficiently dissipate or conduct away heat. Do this, for example, by attaching a heatsink to the anode metal base.
If the lamp holder makes poor contact with the metal base or contact resistance increases due to an oxidized contact piece, the lamp operating
temperature will rise abnormally. Take sufficient precautions to avoid this.
Forced air cooling by fan is necessary for lamps of 250 W or more. The cooling fan must be designed to continue operation for 3 minutes to 5
minutes even after the lamp is turned off so that the fan will not stop during lamp operation.
E. Maintain adequate insulation to avoid trigger voltage leakage.
Use high quality insulation materials and maintain sufficient insulation gaps since an extremely high trigger voltage of 20 kV to 30 kV is applied
to the lamp for start-up. (An insulation gap of 1 cm will withstand only about 10 kV, though this also depends on relative humidity. We recommend an insulation gap of at least 3 cm.)
Use a power supply cable capable of withstanding high voltages more than 30 kV. To avoid electrical leakage from the cable surface, do not
bundle it up during wiring. The power cable layout should be as short as possible, and should not be passed through a metal opening (or should
not be in contact with a metal surface) of the chassis or enclosure. If such a cable layout is not practical, use high-quality silicon insulating tube
to cover the power cable, or install insulating material around the metal opening (or metal surface).
15
WARNING
CAUTION
WARRANTY
●Lamps emit ultraviolet radiation. Never stare directly into the operating lamp.
• Ultraviolet radiation will irritate the eyes and might impair eyesight.
●Do not allow skin to be exposed to ultraviolet radiation.
• Ultraviolet radiation may cause skin inflammation.
●Do not bring the lamp close to any flammable materials such as cloth or paper.
• Doing so might cause fires.
●The lamp remains at high temperatures during and shortly after operation. Never let any part of the heated lamp come
in contact with your hands or skin.
• The heated lamp will cause burns.
●Be careful not to drop the lamp, subject it to impacts, apply excessive force or scratch it, because the pressure inside
the glass bulb is very high and might cause it to rupture.
• Injury may result if the lamp is broken.
●Always operate the lamp after installing it in the lamp housing.
• Injury may result if the lamp is broken.
●Always turn off the power supply when installing or removing the lamp, or when cleaning the lamp or housing.
• Failure to do this may result in electrical shocks, pain in the eyes, damage to eyesight or skin burns.
●Install the lamp in the correct direction and polarity.
• Incorrect installation might damage the lamp.
●Be sure to use a power supply that provides an optimal current value for the lamp.
• Using the wrong power supply might cause overheating and damage the lamp.
●Do not use the lamp in damp locations subject to raindrops or water droplets, high humidity, etc.
• Operating the lamp in high humidity may result in electrical shocks or damage the lamp.
●Always wear a protective mask and garment when installing or removing the lamp.
• If broken, exploding glass fragments may cause injury.
Lamps are warranted for a period of one year from the date of shipment. If a lamp is found to be defective within this warranty
period, Hamamatsu will replace the defective lamp without charge. (This warranty is limited to replacement of the defective
lamp.) Even if within the warranty period (one year), the warranty shall not apply to cases where the lamp operation time has
exceeded the guaranteed life, or the trouble was caused by incorrect operation or natural or man-made disasters.
RELATED PRODUCTS
Super-Quiet Xenon Flash Lamp
Xenon flash lamps feature a compact construction, lower heat generation, and stable light
output with instantaneously higher peaks compared to xenon lamps.
Hamamatsu provides various types of xenon flash lamps such as the SQ type with high stability
and long service life, the HQ type for general use, a high power type with a built-in reflector, and
60 W type sealed in a metal can. Select the lamp that best matches your application.
These lamps are widely used for various kinds of tasks including flash lamps and strobescopes
for high-speed cameras, factory automation, chemical analysis and biological studies.
Long Life 100 W Xenon Short Arc Reflector Lamp L10878
The L10878 consists of a long-life 100 W xenon lamp precisely assembled with a condenser reflector.
The L10878 does not require optical systems and optical axis adjustment mechanisms that are
necessary for ordinary xenon lamps. This simplifies equipment design and makes lamp replacement easy since no optical axis adjustment is required.
Calibrated Xenon Lamp Light Source L7810, L7810-02
(Manufactured upon receiving your order)
These light sources deliver the extremely high levels of "stability" and "repeatability" essential to
a calibrated light source. These are available as an optimal set including a lamp, lamp housing
and power supply, so that anyone can easily reproduce a highly stable light output.
Since we are certified as an ASNITE-Calibration laboratory, we are capable of calibrating spectral irradiance over a wide range from 200 nm to 800 nm (L7810-02).
The spectral range at wavelengths shorter than 250 nm is calibrated based on the ASNITE calibration system (Accreditation System of National Institute of Technology and Evaluation), while
the spectral range at wavelengths longer than 250 nm is calibrated based on the JCSS (Japan
Calibration Service System).
Left: Lamp housing, Right: Power supply
Subject to local technical requirements and regulations, availability of products included in this promotional material may vary. Please consult with our sales office.
Information furnished by HAMAMATSU is believed to be reliable. However, no responsibility is assumed for possible inaccuracies or omissions. Specifications are
subject to change without notice. No patent rights are granted to any of the circuits described herein. ©2012 Hamamatsu Photonics K.K.
HAMAMATSU PHOTONICS K.K.
www.hamamatsu.com
HAMAMATSU PHOTONICS K.K., Electron Tube Division
314-5, Shimokanzo, Iwata City, Shizuoka Pref., 438-0193, Japan, Telephone: (81)539/62-5248, Fax: (81)539/62-2205
U.S.A.: Hamamatsu Corporation: 360 Foothill Road, P. O. Box 6910, Bridgewater. N.J. 08807-0910, U.S.A., Telephone: (1)908-231-0960, Fax: (1)908-231-1218 E-mail: [email protected]
Germany: Hamamatsu Photonics Deutschland GmbH: Arzbergerstr. 10, D-82211 Herrsching am Ammersee, Germany, Telephone: (49)8152-375-0, Fax: (49)8152-2658 E-mail: [email protected]
France: Hamamatsu Photonics France S.A.R.L.: 19, Rue du Saule Trapu, Parc du Moulin de Massy, 91882 Massy Cedex, France, Telephone: (33)1 69 53 71 00, Fax: (33)1 69 53 71 10 E-mail: [email protected]
United Kingdom: Hamamatsu Photonics UK Limited: 2 Howard Court, 10 Tewin Road Welwyn Garden City Hertfordshire AL7 1BW, United Kingdom, Telephone: 44-(0)1707-294888, Fax: 44(0)1707-325777 E-mail: [email protected]
North Europe: Hamamatsu Photonics Norden AB: Smidesvägen 12, SE-171-41 SOLNA, Sweden, Telephone: (46)8-509-031-00, Fax: (46)8-509-031-01 E-mail: [email protected]
TLSX1044E05
Italy: Hamamatsu Photonics Italia: S.R.L.: Strada della Moia, 1/E, 20020 Arese, (Milano), Italy, Telephone: (39)02-935 81 733, Fax: (39)02-935 81 741 E-mail: [email protected]
China: Hamamatsu Photonics (China) Co., Ltd.: 1201 Tower B, Jiaming Center, 27 Dongsanhuan Road North, Chaoyang District, Beijing 100020, China, Telephone: (86)10-6586-6006, Fax: (86)10-6586-2866 E-mail: [email protected]
SEPT. 2012 IP