HAMAMATSU E7536

For 150 W/200 W
Xenon lamps and Mercury-Xenon lamps
NEW HIGH PRECISION
LAMP HOUSING E7536
PATENT PENDING
INTERLOCK FUNCTION
HIGH SAFETY
The internal cooling fan
ensures safe operation.
HIGH OUTPUT INTENSITY
Built-in reflective mirror
ADJUSTABLE OUTPUT LIGHT
The built-in focus lens allows
light flux adjustment.
EASY OPTICAL AXIS
ALIGNMENT DURING
LAMP REPLACEMENT
HIGH ACCURACY
Stationary emission point
ensures high accuracy.
IMPROVED START-UP
OPERATION
A starter is incorporated.
TLSXF0129
FEATURES
●High accuracy
The E7536 lamp housing was designed to extract the full
capabilities of lamps. One example of this is the stationary
emission point which ensures high accuracy and easy optical design. The E7536 also delivers high output stability,
making it ideally suited for high-precision photometric applications. Light output stability(p-p) is better than 0.3 % Typ.
(when used with a Hamamatsu Xenon lamps) or 1.0 % Typ.
(when used with a Hamamatsu Mercury-Xenon lamps).
●High output intensity and collimated light flux
A reflective mirror and focus lens are incorporated. The mirror collects light from a lamp very efficiently to obtain a high
output of over 1.5 times. The focus lens can be used to provide collimated light output.
●Built-in starter for improved lamp start-up operation
The built-in starter prevents high-voltage leakage, thus
improving start-up operation of the lamp and also minimizing noise which might otherwise occur at lamp start-up.
●Adjustable light flux
The focus lens can be moved back and forth by turning the
screw on the front flange (with the accessory tool), to adjust
the output light flux. The desired light flux can be easily
obtained to match your specific application.
●Easy optical axis adjustment during lamp replacement
The optical axis can be easily adjusted by using the accessory tool, without removing any lamp housing covers. Three
adjustment screws are provided in easy-to-access positions: one on the side of the housing (for right-left movement of the lamp), one at the upper part on the rear (for vertical movement of the lamp), and one in the center on the
rear (for back and forth movement of the mirror).
●Interlock function
If the side cover becomes loose or the temperature in the
lamp housing rises to an abnormal level, the interlock
function triggers automatically to stop lamp operation.
●High safety
The built-in cooling fan maintains the surface temperature of
the lamp housing to a safe level below +40 °C.
FEATURES
HIGH PRECISION LAMP HOUSING
Parameter
Suitable Lamps (Rating and kind)
Fused Silica Window
Ozone-free Silica Window
Suitable Lamps
Type No.
Lamp Current
Lamp Voltage
Lamp
Description/Value
150 W
150 W (GS)
200 W
Xenon Lamps
Mercury-Xenon Lamps
Mercury-Xenon Lamps
L2482
L2273
L2423
L7047
L2274
L2570
8.5 A
8.0 A
7.5 A
18 V Typ.
24 V Typ.
20 V Typ.
Fused Silica
30 mm
F = 30 mm (550 nm)
Collimating
BK7 Al + MgF2 Coating (All reflection)
30 mm
R = 30 mm
140 mm (exclude plastic feet height)
30 kV Typ.
Forced Air Cooling (Built-in automatic cooling fanA)
0 °C to +40 °C
+5 °C to +35 °C
30 % to 90 % (without moisture condensation)
100 mm × 100 mm × 280 mm (exclude projection part)
Approx. 3.5 kg
C4264, C7535
C7535
C4263, C7535
150 W
Xenon Lamps
L2175
L2195
Material
Dimension
Focus Lens
Focal Point
Optical
Light Output
Material
Reflective Mirror Dimension
Curvature
Optical Axis Height
Starter Output Voltage
Cooling Function
Operating Ambient Temperature
Recommended Operating Temperature
Operating Humidity
Dimensions (W × H × D)
Weight
Suitable Power Supply Type No.
NOTE: A The cooling fan automatically starts when the temperature rises inside the lamp housing.
DIMENSIONAL OUTLINES (Unit: mm)
COOLING FAN FRONT VIEW
SIDE COVER
MOUTING
SCREW
4-M3 HEX
SOCKET
HEAD BOLT
FOCUS LENS
BACK AND FORTH
ADJUSTMENT
SCREW
M3 HEX SOCKET
HEAD BOLT
SIDE VIEW
SIDE COVER
(REMOVE THIS
COVER WHEN
REPLACING LAMP)
LAMP
VERTICAL
ADJUSTMENT
SCREW
APPLICATIONS
●Light sources in various experiments
●Light sources in spectrophotometry
STABILITY
M37 P=1
77
5
10
50
100
MIRROR BACK
AND FORTH
ADJUSTMENT
SCREW
100
1.0 %
LAMP
RIGHT-LEFT
ADJUSTMENT
SCREW
M3 HEX
SOCKET
HEAD BOLT
LIGHT OUTPUT
5
140
OUTPUT
LENS
( 30)
60
280
TLSXB0107EB
5 min
5
BOTTOM VIEW
TIME
39
78
M4
39
Block Diagram for Measurement
LAMP
HOUSING
E7536
4-M4
PLASTIC FEET ARE ATTACHED
TO THE BOTTOM OF THE UNIT
BUT CAN BE REMOVED TO USE
THEIR HOLES FOR INSTALLATION
OF THE LAMP HOUSING.
78
TLSXA0083EB
POWER SUPPLY
C7535
0.1 % ND FILTER
10 % ND FILTER
APERTURE 1 × 1 mm
DIFFUSER
300 mm
150 W XENON LAMP
L2274
METER
SILICON
PHOTODIODE
* PATENT PENDING: JAPAN 2
COMPUTER
TLSXC0041EB
Subject to local technical requirements and regulations, availability of products included in this promotional material may vary. Please consult with our sales office.
Information furnished by HAMAMATSU is believed to be reliable. However, no responsibility is assumed for possible inaccuracies or omissions. Specifications are subject
to change without notice. No patent rights are granted to any of the circuits described herein. ©1999 Hamamatsu Photonics K.K
HAMAMATSU PHOTONICS K.K., Electron Tube Center
314-5, Shimokanzo, Toyooka-village, Iwata-gun, Shizuoka-ken, 438-0193, Japan, Telephone: (81)539/62-5248, Fax: (81)539/62-2205
U.S.A.: Hamamatsu Corporation: 360 Foothill Road, P. O. Box 6910, Bridgewater. N.J. 08807-0910, U.S.A., Telephone: (1)908-231-0960, Fax: (1)908-231-1218
Germany: Hamamatsu Photonics Deutschland GmbH: Arzbergerstr. 10, D-82211 Herrsching am Ammersee, Germany, Telephone: (49)8152-375-0, Fax: (49)8152-2658
France: Hamamatsu Photonics France S.A.R.L.: 8, Rue du Saule Trapu, Parc du Moulin de Massy, 91882 Massy Cedex, France, Telephone: (33)1 69 53 71 00, Fax: (33)1 69 53 71 10
United Kingdom: Hamamatsu Photonics UK Limited: Lough Point, 2 Gladbeck Way, Windmill Hill, Enfield, Middlesex EN2 7JA, United Kingdom, Telephone: 44(20)8-367-3560, Fax: 44(20)8-367-6384
North Europe: Hamamatsu Photonics Norden AB: Smidesvägen 12, SE-171-41 SOLNA, Sweden, Telephone: (46)8-509-031-00, Fax: (46)8-509-031-01
Italy: Hamamatsu Photonics Italia: S.R.L.: Strada della Moia, 1/E, 20020 Arese, (Milano), Italy, Telephone: (39)02-935 81 733, Fax: (39)02-935 81 741
TLSX1030E02
NOV. 1999 SI
(500)