MetroView™ FG 501T Window Wall Urban Elegance with an Economical Point of View Sleek, efficient and versatile. FG 501T Window Wall – the first in the MetroView™ Window Wall series – packs the desired aesthetics of a curtain wall into a cost-efficient window wall system. Ideal for mid-rise commercial projects and sophisticated multi-family housing, MetroView™ FG 501T Window Wall delivers the refined design features that are so popular in today’s urban and near-urban cityscapes. MetroView™ FG 501T Window Wall offers the look of a true curtain wall with a slab-to-slab aluminum frame design. For maximum square footage in interior spaces, FG 501T Window Wall is engineered for shallow horizontal inside glazing with the glass set to the front of the system. Screw spline fabrication and joinery means easy construction and low installation costs. And for designs that put skylines within immediate reach, balcony doors can be easily and seamlessly integrated into the system. With air and water performance equal to many curtain walls and a range of aesthetic options including slab edge covers for a seamless transition between floors, MetroView™ FG 501T Window Wall offers a beautiful frame for life. Performance Aesthetics and Versatility MetroView™ FG 501T Window Wall is an economical solution that does not compromise performance to achieve the true look of a curtain wall. The framing process is as streamlined as its appearance, with simple two-piece receptors designed for efficient installation. Optional outside glazing allows for job-site flexibility. It is easy to achieve dramatic floor-to-ceiling views with FG 501T Window Wall. The 2-1/4" sightline and standard 5" depth makes it easy to achieve stylish urban aesthetics. For clean design lines, the system features a slab-to-slab application with an integrated slab edge. The system provides an appealing look for any type of application and accommodates single- and multi-punched openings or ribbon windows. Corner members for either 90° or 135° applications increase design flexibility, and expansion verticals can be incorporated as desired for a truly customized application. Thermal simulations showing temperature variations from exterior/ cold side to interior/warm side Head member assembly with 1" glass Sill member assembly with 1" glass Thermal performance is enhanced with our IsoLock™ thermal break. The factorysupplied pour and debridge thermal break involves pouring liquid polyurethane into a cavity or thermal pocket, allowing it to harden and then cutting away a small section of aluminum opposite the pour area to fully separate the exterior aluminum from the interior aluminum. This thermal barrier improves the U-factor and condensation resistance and also means there are fewer parts to cut and assemble. Additionally, the IsoLock™ thermal break process is used to eliminate expansion and contraction of the polyurethane. Prior to the pouring operation, the aluminum is lanced into the cavity at a predetermined increment. The lanced aluminum creates a positive interlock in the polyurethane before it hardens, eliminating any potential for shrinkage. The mechanical locks, combined with the adhesive bond of the polyurethane to the aluminum, create a composite section used to meet design wind loads. Painted finishes in standard and custom choices are available. Integrated slab edge cover receptor Accepts insulating glass units for added occupant comfort Sleek 2-1/4" sightline Screw spline joinery for easy construction and low installation cost Balcony doors easily integrate into system IsoLock™ thermal break The system is fully tested according to industry standards, as indicated below: Performance Test Standards Air Infiltration Water Severe Wind-Driven Rain Structural – Uniform Wind Load Large Missile Impact Acoustical Testing, STC and OITC Thermal Transmittance – U-Factor Condensation Resistance (CRF and CR) Overall Solar Heat Gain (SHGC, VT) ASTM E283, NFRC 400, TAS 202 ASTM E331, ASTM E547, TAS 202 AAMA 520 ASTM E330, TAS 202 ASTM E1886, ASTM E1996 AAMA 1801, ASTM E90, ASTM E1425 NFRC 100, AAMA 1503, AAMA 507 AAMA 1503, NFRC 500 AAMA 507, NFRC 200 Sill receptor pocket design Extruded aluminum (shown) or optional Reynobond® Aluminum Composite Material panel Head receptor pocket design Kawneer Company, Inc. Technology Park / Atlanta 555 Guthridge Court Norcross, GA 30092 kawneer.com 770 . 449 . 5555 © Kawneer Company, Inc. 2015 LITHO IN U.S.A. Form No. 15-2200 IsoLock™ and MetroVIew™ are trademarks of Kawneer Company, Inc. and Alcoa Inc. and Reynobond® is a registered trademark of Alcoa Inc. Floor slab FG 501T Window Wall JANUARY, 2015 EC 97911-072 Features Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. • FG 501T Window Wall is an inside glazed system • 2-1/4" sight line with standard 5" system depth • IsoLockTM lanced pour and debridged 3/8" thermal break • Screw spline fabrication and joinery • 1" Infill • Silicone compatible glazing materials for long lasting seals • Inside and outside corner members are available for 90° and 135° applications • Incorporates expansion verticals as required • Permanodic™ anodized finishes in seven choices • Painted finishes in standard and custom choices Optional Features • Integrates with Kawneer GLASSvent™ UT Windows • Entrances and balcony door options • Strap anchors • Optional slab edge covers (Extruded / ACM panel) • Outside glazed option • Heavy weight mullions • Steel reinforcing • Head receptor reinforcing clip • Wedge gasket at interior head receptor stop Product Applications • Ribbon windows • Ideal for single and multi-lite punched openings © Kawneer Company, Inc., 2015 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. FEATURES For specific product applications, Consult your Kawneer representative. kawneer.com ADMD220 1 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. FG 501T Window Wall BLANK PAGE ADMD220 kawneer.com © Kawneer Company, Inc., 2015 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 2 JANUARY, 2015 EC 97911-072 FG 501T Window Wall JANUARY, 2015 EC 97911-072 3 INDEX Architects – Most extrusion and window types illustrated in this catalog are standard products for Kawneer. These concepts have been expanded and modified to afford you design freedom. Some miscellaneous details are non-standard and are intended to demonstrate how the system can be modified to expand design flexibility. Please contact your Kawneer representative for further assistance. LAWS AND BUILDING AND SAFETY CODES GOVERNING THE DESIGN AND USE OF GLAZED ENTRANCE, WINDOW, AND CURTAIN WALL PRODUCTS VARY WIDELY. KAWNEER DOES NOT CONTROL THE SELECTION OF PRODUCT CONFIGURATIONS, OPERATING HARDWARE, OR GLAZING MATERIALS, AND ASSUMES NO RESPONSIBILITY THEREFOR. Metric (SI) conversion figures are included throughout these details for reference. Numbers in parentheses ( ) are millimeters unless otherwise noted. The following metric (SI) units are found in these details: m –meter cm – centimeter mm –millimeter s –second Pa –pascal MPa –megapascal © Kawneer Company, Inc., 2015 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. PICTORIAL VIEW ..................................................................................4 FRAMING DETAILS ........................................................................... 5-7 SLAB EDGE COVER DETAILS ..............................................................8 CORNER DETAILS .................................................................................9 GLASSvent™ UT WINDOW DETAILS.................................................10 MISCELLANEOUS DETAILS................................................................11 WIND LOAD/DEADLOAD CHARTS .............................................. 12-15 THERMAL CHARTS........................................................................ 16-20 Kawneer reserves the right to change configurations without prior notice when deemed necessary for product improvement. kawneer.com ADMD220 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. FG 501T Window Wall PICTORIAL VIEW ADMD220 kawneer.com © Kawneer Company, Inc., 2015 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 4 JANUARY, 2015 EC 97911-072 1/2" (13) 1 1/8" (29) 3 SILL kawneer.com DLO 2 1/4" (57) 2 INTERMEDIATE HORIZONTAL 2 1/2" (64) FH / ML DLO DLO 1 5/8" (41) FH / ML OD 2" (51) 1 1/2" (38) 1/2" (13) Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 1 HEAD OD DLO © Kawneer Company, Inc., 2015 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. JANUARY, 2015 FG 501T Window Wall EC 97911-072 SCALE 3" = 1'-0" 4 5 1" (25) ADMD220 2 1/4" (57) FW DLO DLO DLO 4 JAMB 3" (76) 6 EXPANSION MULLION 2 1/4" (64) OD 5 MULLION DLO 5 RIBBON FRAMING DETAILS 1 6 2 3 ELEVATION IS NUMBER KEYED TO DETAILS INSIDE GLAZED 5" (127) DLO DLO DLO 2 1/4" (57) DLO 1 5/8" (41) 1/2" (13) SCALE 3" = 1'-0" 4 5 6 2 3 ELEVATION IS NUMBER KEYED TO DETAILS OUTSIDE GLAZED 1" (25) ADMD220 2 1/4" (57) Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 2" (51) 1 1/2" (38) RIBBON FRAMING DETAILS FW DLO DLO DLO 4 JAMB 3" (76) 2 1/4" (64) DLO OD 5 MULLION DLO 6 EXPANSION MULLION kawneer.com © Kawneer Company, Inc., 2015 DLO OD FH / ML FG 501T Window Wall Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 2 1/2" (64) FH / ML 2 INTERMEDIATE HORIZONTAL 1/2" (13) 3 SILL OD 1 HEAD 1 1/8" (29) 6 JANUARY, 2015 EC 97911-072 1 5" (127) 1/2" (13) 1 1/8" (29) 3 SILL kawneer.com DLO 2 1/4" (57) 2 INTERMEDIATE HORIZONTAL 2 1/2" (64) FH / ML DLO DLO OD 1 5/8" (41) FH / ML 2" (51) 1 1/2" (38) 1/2" (13) Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 1 HEAD OD DLO © Kawneer Company, Inc., 2015 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. JANUARY, 2015 FG 501T Window Wall EC 97911-072 PUNCHED OPENING FRAMING DETAILS SCALE 3" = 1'-0" 1 4 5 2 3 ELEVATION IS NUMBER KEYED TO DETAILS INSIDE GLAZED 5" (127) 1" (25) DLO HEAD AND SILL SHOWN WITH OPTIONAL STRAP ANCHOR ADMD220 2 1/4" (57) FW DLO OD 4 JAMB 2 1/4" (64) 5 MULLION DLO 7 STANDARD SILL RECEPTOR WITH 7" SLAB COVER (8" SLAB COVER SIMILAR) ADMD220 1 5/8" (41) 2" (51) 1/2" (13) 1/2" (13) 1/2" (13) 1 3/4" (44) 1 1/8" (29) 2 1/2" (64) FH / ML OD 2 1/2" (64) FH / ML OD DLO DLO 2-PIECE SILL RECEPTOR Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 6 1/4" or 7 1/4" (159) or (184) 7" or 8" (178) or (203) 6 1/4" or 7 1/4" (159) or (184) 1/2" (13) 1 3/4" (44) 1 1/8" (29) SLAB EDGE COVER DETAILS 2-PIECE SILL RECEPTOR WITH 7" SLAB COVER (8" SLAB COVER SIMILAR) kawneer.com © Kawneer Company, Inc., 2015 1 1/2" (38) 2" (51) 7" or 8" (178) or (203) SILL RECEPTOR FH / ML OD 1 5/8" (41) 1 1/2" (38) FG 501T Window Wall Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. DLO DLO OD FH / ML 8 JANUARY, 2015 EC 97911-072 SCALE 3" = 1'-0" SLAB EDGE COVERS (INSIDE GLAZED SHOWN, OUTSIDE GLAZED SIMILAR) © Kawneer Company, Inc., 2015 4 DLO kawneer.com O D ) D LO 7 1/4" (184) OD FW Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. DLO FW 11 4 "( 1/ 2 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. DLO JANUARY, 2015 FG 501T Window Wall EC 97911-072 CORNER DETAILS SCALE 3" = 1'-0" DLO 7 1/4" (184) FW FW DLO FW 4 1/2" (114) 135° OUTSIDE CORNER ADMD220 2 1/4" (57) OD OD 90° OUTSIDE CORNER 90° INSIDE CORNER FW 2 7/16" (62) OD OD 135° INSIDE CORNER 9 2 1/4" (57) 1 13/16" (46) 2 1/4" (57) 1 13/16" (46) DLO DLO DLO DLO WD 2 SILL AT HORIZONTAL ADMD220 WD 1/8" (3) 5 3 2 5 4 ELEVATION IS NUMBER KEYED TO DETAILS 1/8" (3) GLASSvent™ UT WINDOWS SHOWN WITH INSIDE GLAZED FRAMING MEMBERS, OUTSIDE GLAZED SIMILAR 1 HEAD 1 13/16" (46) 2 1/4" (57) WD DLO DLO 5 JAMB Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. GLASSvent™ ut WINDOWs DETAILS 3 HEAD AT HORIZONTAL 4 SILL kawneer.com © Kawneer Company, Inc., 2015 2 1/4" (57) 1 13/16" (46) DLO 2 1/4" (57) 1 13/16" (46) 1/8" (3) SCALE 3" = 1'-0" WD DLO WD DLO FG 501T Window Wall Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 1/8" (3) 1/8" (3) DLO 10 JANUARY, 2015 EC 97911-072 PROJECT-OUT WINDOW SHOWN CASEMENT OUTSWING ALSO AVAILABLE 1 FG 501T Window Wall JANUARY, 2015 EC 97911-072 MISCELLANEOUS DETAILS HEAVY STOP REINFORCING CLIP HEAD WITH REINFORCING CLIP (INSIDE OR OUTSIDE GLAZED) HEAD WITH BLIND POCKET (INSIDE GLAZED ONLY) 2 1/4" (57) DLO 5" (127) DLO Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. SCALE 3" = 1'-0" STRAP ANCHOR AT HEAD 3" (76) STRAP ANCHOR AT SILL © Kawneer Company, Inc., 2015 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. HORIZONTAL WITH BLIND APPLICATION (INSIDE GLAZED ONLY) DLO 2 1/4" (57) DLO HEAVY MULLION DLO 2 1/4" (57) DLO HEAVY MULLION W/ STEEL REINFORCING DLO ADMD220 DLO EXPANSION MULLION W/ STEEL REINFORCING (INSIDE GLAZED SHOWN, OUTSIDE GLAZED SIMILAR) kawneer.com 3" (76) 11 12 FG 501T Window Wall JANUARY, 2015 WIND LOAD / DEADLOAD CHARTS EC 97911-072 DEAD LOAD CHARTS Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Horizontal or deadload limitations are based upon 1/8" (3.2), maximum allowable deflection at the center of an intermediate horizontal member. The accompanying charts are calculated for 1" (25) thick insulating glass or 1/4" (6) thick glass supported on two setting blocks placed at the loading points shown. ADMD220 kawneer.com © Kawneer Company, Inc., 2015 Mullions are designed for deflection limitations in accordance with AAMA TIR-A11 of L/175 up to 13'-6" and L/240 +1/4" above 13'-6". These curves are for mullions WITH HORIZONTALS and are based on engineering calculations for stress and deflection. Allowable wind load stress for ALUMINUM 15,152 psi (104MPa), STEEL 30,000 psi (207MPa.). Charted curves, in all cases are for the limiting value. If the design wind load is determined through the analytical procedures of ASCE/SEI 7-10 or earlier editions, the load shall be based on the nominal loads used in allowable stress design. A 4/3 increase in allowable stress has not been used to develop these curves. For special situations not covered by these curves, contact your Kawneer representative for additional information. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. WIND LOAD CHARTS FG 501T Window Wall JANUARY, 2015 EC 97911-072 WIND LOAD CHARTS WITH HORIZONTALS A = 15 PSF (720) B = 20 PSF (960) C = 30 PSF (1440) D = 40 PSF (1920) E = 45 PSF (2160) MULLION CENTERS IN METERS 1.0 2.0 6.0 19 WITHOUT HORIZONTALS MULLION CENTERS IN METERS 1.0 18 4.0 12 11 A 10 B 9 3.0 C 8 D E 7 6 0 1 2 3 4 5 6 7 MULLION HEIGHT IN FEET 14 13 182101 15 17 182003 5.0 16 MULLION HEIGHT IN METERS 15 14 12 B 10 C D E 9 7 I = 5.310 (221.01 x 104) S = 2.007 (32.88 x 103) 3.0 2.0 6 5 8 0 1 2 3 4 5 6 7 8 MULLION CENTERS IN FEET A = 15 PSF (720) B = 20 PSF (960) C = 30 PSF (1440) D = 40 PSF (1920) E = 50 PSF (2400) MULLION CENTERS IN METERS 2.0 20 WITHOUT HORIZONTALS MULLION CENTERS IN METERS 1.0 2.0 20 6.0 19 6.0 19 18 14 4.0 13 12 A 11 B 10 3.0 C 9 8 D 7 6 E 0 1 2 3 4 5 6 7 2.0 182102/182003 I = 7.22 (300.51 x 104) S = 2.779 (45.53 x 103) MULLION HEIGHT IN FEET 15 17 182102 5.0 16 182003 17 MULLION HEIGHT IN METERS 18 MULLION HEIGHT IN FEET A 11 MULLION CENTERS IN FEET 1.0 4.0 13 8 182101/182003 2.0 5.0 16 15 14 13 A 12 C 10 D E 9 8 7 ADMD220 3.0 2.0 6 0 1 2 3 4 5 6 7 8 MULLION CENTERS IN FEET MULLION CENTERS IN FEET 4.0 B 11 5 8 5.0 16 MULLION HEIGHT IN METERS MULLION HEIGHT IN FEET 17 kawneer.com 6.0 MULLION HEIGHT IN METERS 18 5 2.0 20 19 WITH HORIZONTALS © Kawneer Company, Inc., 2015 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 20 5 13 FG 501T Window Wall JANUARY, 2015 WIND LOAD CHARTS EC 97911-072 MULLION CENTERS IN METERS 1.0 2.0 20 WITHOUT HORIZONTALS MULLION CENTERS IN METERS 1.0 6.0 19 12 A 11 B 3.0 10 C 9 8 D 7 6 E 0 1 2 3 4 5 6 7 182102/182003 WITH 2" X 1/2" STEEL BAR 8 15 14 11 C 10 D 9 3.0 E 7 2.0 6 5 0 1 2 3 4 5 6 7 8 MULLION CENTERS IN FEET WITH HORIZONTALS A = 15 PSF (720) B = 20 PSF (960) C = 30 PSF (1440) D = 40 PSF (1920) E = 50 PSF (2400) MULLION CENTERS IN METERS 2.0 20 WITHOUT HORIZONTALS MULLION CENTERS IN METERS 1.0 2.0 20 6.0 19 6.0 19 16 15 14 4.0 13 12 A 11 B 10 3.0 C 9 8 D 7 E 6 0 1 2 3 4 5 6 7 2.0 17 182120 182120 I = 6.512 (271.04 x 104) S = 2.571 (42.13 x 103) MULLION HEIGHT IN FEET 5.0 MULLION HEIGHT IN METERS 17 15 14 MULLION CENTERS IN FEET 4.0 13 A 12 11 B 10 C 3.0 9 D E 8 7 2.0 6 5 8 5.0 16 MULLION HEIGHT IN METERS 18 18 MULLION HEIGHT IN FEET 4.0 B 12 MULLION CENTERS IN FEET 1.0 A 13 8 I = 5.310 (221.01 x 104) S = 2.007 (32.88 x 103) Is = 0.333 (13.86 x 104) Ss = 0.333 (5.45 x 103) 2.0 5.0 16 MULLION HEIGHT IN METERS 4.0 13 MULLION HEIGHT IN FEET 14 17 182102 15 2" X 1/2" STEEL BAR 182003 MULLION HEIGHT IN FEET 5.0 16 MULLION HEIGHT IN METERS 18 17 5 6.0 19 18 5 2.0 20 0 1 2 3 4 5 6 7 8 MULLION CENTERS IN FEET ADMD220 kawneer.com © Kawneer Company, Inc., 2015 A = 15 PSF (720) B = 20 PSF (960) C = 30 PSF (1440) D = 40 PSF (1920) E = 50 PSF (2400) Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. WITH HORIZONTALS Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 14 © Kawneer Company, Inc., 2015 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. HEIGHT IN FEET Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. kawneer.com 9 7 8 6 0 2.0 5 4 3 1.0 2 0 1 2 3 4 5 6 7 HEIGHT IN FEET HEIGHT IN METERS EC 97911-072 182112 (1" INFILL) (1" INFILL) WIDTH IN METERS WIDTH IN METERS 13 13 12 12 11 11 10 10 3.0 B 1 8 WIDTH IN FEET ADMD220 9 7 8 6 0 2.0 5 4 3 2 B 1.0 1 0 1 WIDTH IN FEET 2 3 4 5 6 7 8 HEIGHT IN METERS JANUARY, 2015 FG 501T Window Wall 15 DEAD LOAD CHARTS A = 1/4 POINT LOADING B = 1/8 POINT LOADING 182116 3.0 FG 501T Window Wall JANUARY, 2015 THERMAL CHARTS EC 97911-072 Project Specific U-Factor Example Calculation 15'-8" Frame Width Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 2'-0" D.L.O. 9'-6" Frame Height 7'-0" D.L.O. 5'-0" D.L.O. Example Glass U-Factor = 0.42 Btu/hr x ft2 x °F Total Daylight Opening = 3(5' x 7') + 3(5' x 2') = 135 ft2 Total Projected Area= (Total Daylight Opening + Total Area of Framing System) = 15'-8" x 9'-6" = 148.83 ft2 Percent of Glass = (Total Daylight Opening ÷ Total Projected Area) = (135 ÷ 148.83)100 = 91% System U-Factor vs Percent of Glass Area 0.80 0.65 E n PL ig M es A rD EX Fo (N 0.60 ot COG U-Factor 0.55 0.50 0.49 0.45 0.40 0.35 0.30 ) 0.48 0.46 0.44 0.42 0.40 0.38 0.36 0.34 0.32 0.30 0.28 0.26 0.24 0.22 0.20 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 0.70 0.25 70 75 80 85 90 91% 0.20 Vision Area / Total Area % Based on 91% glass and center of glass U-Factor of 0.42 System U-Factor is equal to 0.49 Btu/hr x ft2 x °F ADMD220 kawneer.com © Kawneer Company, Inc., 2015 0.75 95 16 FG 501T Window Wall JANUARY, 2015 EC 97911-072 THERMAL CHARTS System U-Factor vs Percent of Glass Area System U-Factor (Btu/hr x ft2 x °F) Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. Note: Values in parentheses are metric. COG=Center of Glass. Charts are generated per AAMA 507. COG U-factor 0.48 (2.72) 0.46 (2.61) 0.44 (2.50) 0.42 (2.39) 0.40 (2.27) 0.38 (2.16) 0.36 (2.05) 0.32 (1.82) 0.30 (1.71) 0.28 (1.59) 0.26 (1.48) 0.24 (1.37) 0.22 (1.25) 0.20 (1.14) 0.18 (1.02) 0.16 (0.91) 0.14 (0.79) 0.12 (0.68) 0.10 (0.57) © Kawneer Company, Inc., 2015 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 0.34 (1.93) Vision Area / Total Area % Notes for System Y-Factor, Shgc and VT charts: For glass values that are not listed, linear interpolation is permitted. Glass properties are base on center of glass values and are obtained from your glass supplier. kawneer.com 17 ADMD220 Vision Area / Total Area % (Total Daylight Opening / Projected Area) COG VT Visible Transmittance (VT) vs Percent of Vision Area Vision Area / Total Area % (Total Daylight Opening / Projected Area) ADMD220 kawneer.com © Kawneer Company, Inc., 2015 THERMAL CHARTS Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. FG 501T Window Wall Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. System SHGC COG SHGC System VT 18 JANUARY, 2015 EC 97911-072 System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area Charts are generated per AAMA 507 FG 501T Window Wall JANUARY, 2015 THERMAL PERFORMANCE MATRIX (NFRC SIZE) EC 97911-072 Glass U-Factor 3 Overall U-Factor 4 0.48 0.58 0.46 0.56 0.44 0.55 0.42 0.53 0.40 0.52 0.38 0.50 0.36 0.49 0.34 0.47 0.32 0.46 0.30 0.44 0.28 0.43 0.26 0.41 0.24 0.39 0.22 0.38 0.20 0.36 0.18 0.34 0.16 0.33 0.14 0.31 0.12 0.30 0.10 0.28 NOTE: For glass values that are not listed, linear interpolation is permitted. 1. U-Factors are determined in accordance with NFRC 100. 2. SHGC and VT values are determined in accordance with NFRC 200. 3. Glass properties are based on center of glass values and are obtained from your glass supplier. 4. Overall U-Factor, SHGC, and VT Matricies are based on the standard NFRC specimen size of 2000mm wide by 2000mm high (78-3/4" by 78-3/4"). © Kawneer Company, Inc., 2015 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. Thermal Transmittance1 (BTU/hr • ft 2 • °F) kawneer.com ADMD220 19 FG 501T Window Wall JANUARY, 2015 THERMAL CHARTS EC 97911-072 Visible Transmittance 2 Glass SHGC 3 Overall Glass U-Factor 4 Glass VT 3 Overall VT 4 0.75 0.65 0.75 0.64 0.70 0.61 0.70 0.59 0.65 0.57 0.65 0.55 0.60 0.52 0.60 0.51 0.55 0.48 0.55 0.47 0.50 0.44 0.50 0.42 0.45 0.40 0.45 0.38 0.40 0.35 0.40 0.34 0.35 0.31 0.35 0.30 0.30 0.27 0.30 0.25 0.25 0.23 0.25 0.21 0.20 0.18 0.20 0.17 0.15 0.14 0.15 0.13 0.10 0.10 0.10 0.08 0.05 0.06 0.05 0.04 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. SHGC Matrix 2 1. U-Factors are determined in accordance with NFRC 100. 2. SHGC and VT values are determined in accordance with NFRC 200. 3. Glass properties are based on center of glass values and are obtained from your glass supplier. 4. Overall U-Factor, SHGC, and VT Matricies are based on the standard NFRC specimen size of 2000mm wide by 2000mm high (78-3/4" by 78-3/4"). ADMD220 kawneer.com © Kawneer Company, Inc., 2015 NOTE: For glass values that are not listed, linear interpolation is permitted. Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 20