MAY, 2016 1600UT System™2 Curtain Wall Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. EC 97911-095 FEATURES Features • 1600UT SystemTM2 is a high thermal performance, structural silicone glazed curtain wall system • Innovative design delivers high thermal performance while leveraging 1600 Wall System architecture • Multiple thermal performance levels resulting from a combination of: - 1" (25.4), 1-1/4" (31.8), 1-5/16" (33.34) double or 1-3/4" (44.5), triple glazed insulating glass units - Aluminum or fiberglass pressure plates • Thermal barrier design ensures high thermal performance without being susceptible to thermal fatigue • Offers integrated entrance framing systems • Corners and splays available • Comprehensively tested to latest high performance air, water, structural and thermal standards • Glass chairs support insulating glass units enabling larger expanses of glass • Pressure equalized system tested with vapor barrier • Two color option • PermanodicTM anodized finishes in seven choices • Painted finishes in standard and custom choices Optional Features • Steel reinforcing • Rain screen and backpans • Deep profile covers and bull nose covers • Deep and heavy-weight mullions • Integrates with standard Kawneer windows and GLASSventTM Windows for curtain wall • Profit$MakerTM plus die sets available © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 1 Product Applications • Ideal for low to mid-rise applications where high thermal performance is desired • High span applications For specific product applications, Consult your Kawneer representative. kawneer.com ADMD081EN Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 1600UT System™2 Curtain Wall BLANK PAGE ADMD081EN kawneer.com © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 2 EC 97911-095 MAY, 2016 MAY, 2016 1600UT System™2 Curtain Wall EC 97911-095 3 INDEX Architects - Most extrusion and window types illustrated in this catalog are standard products for Kawneer. These concepts have been expanded and modified to afford you design freedom. Some miscellaneous details are non-standard and are intended to demonstrate how the system can be modified to expand design flexibility. Please contact your Kawneer representative for further assistance. LAWS AND BUILDING AND SAFETY CODES GOVERNING THE DESIGN AND USE OF GLAZED ENTRANCE, WINDOW, AND CURTAIN WALL PRODUCTS VARY WIDELY. KAWNEER DOES NOT CONTROL THE SELECTION OF PRODUCT CONFIGURATIONS, OPERATING HARDWARE, OR GLAZING MATERIALS, AND ASSUMES NO RESPONSIBILITY THEREFOR. Metric (SI) conversion figures are included throughout these details for reference. Numbers in parentheses ( ) are millimeters unless otherwise noted. © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. PICTORIAL VIEW.................................................................................4 1" INFILL DETAILS...............................................................................5 ENTRANCE DETAILS................................................................. 6-8 CORNERS.......................................................................................9 SPLAYED MULLION OPTIONS....................................................10 WINDOWS................................................................................11,12 1-3/4" INFILL DETAILS......................................................................13 ENTRANCE DETAILS............................................................. 14-16 CORNERS.....................................................................................17 WINDOWS.....................................................................................18 BACKPAN DETAILS......................................................................19,20 MISCELLANEOUS FRAMING.......................................................21,22 ANCHORING.................................................................................23,24 WIND LOAD CHARTS.................................................................. 25-29 DEADLOAD CHARTS.................................................................. 30-34 THERMAL CHARTS .................................................................... 35-48 The following metric (SI ) units are found in these details: m –meter cm – centimeter mm –millimeter s –second Pa –pascal MPa –megapascal Kawneer reserves the right to change configurations without prior notice when deemed necessary for product improvement. kawneer.com ADMD081EN Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 1600UT System™2 Curtain Wall PICTORIAL VIEW ADMD081EN kawneer.com © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 4 EC 97911-095 MAY, 2016 © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 6A 6 6B 5 6 7 kawneer.com 2-1/2" (63.5) MAY, 2016 1600UT System™2 Curtain Wall EC 97911-095 1" INFILL DETAILS SCALE 3" = 1'-0" 1 1A 1 2 2A 3 7A OPTIONAL FIBERGLASS PRESSURE PLATE 6A 6B 1/4" INFILL ADAPTER OPEN BACK JAMB 7A 1/4" INFILL ADAPTER 7B STEEL REINFORCING AS REQUIRED ADMD081EN 1A 4 7 7B TUBE HORIZONTAL 2 ELEVATION IS NUMBER KEYED TO DETAILS 6" (152.4) 7-1/2" (190.5) OPEN BACK HORIZONTAL 2A 3 4 5 5 1600UT System™2 Curtain Wall 6 MAY, 2016 EC 97911-095 NON-THERMAL ENTRANCE DETAILS (1" INFILL) SCALE 3" = 1'-0" 3 4 6 1 1-3/4" (50.8) 2 1/8" (3.2) 2-1/2" (63.5) 5 TRANSOM BAR B/H OR O/P C/H BUTT HUNG OR OFFSET PIVOT WITH SURFACE CLOSER OR FLOOR CLOSER B/H OR O/P 1/8" (3.2) 2-1/2" (63.5) ELEVATION IS NUMBER KEYED TO DETAILS DOOR JAMB 2 1-3/4" (50.8) BUTT HUNG OR OFFSET PIVOT 1A Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 1 1A TRANSOM BAR 2-1/2" (63.5) DOOR JAMB 1/8" (3.2) CENTER HUNG 1-3/4" (50.8) 4 3 TRANSOM BAR CENTER HUNG WITH CONCEALED OVERHEAD OR FLOOR CLOSER 6 2-1/2" (63.5) 3/4" (19.1) TYP. DOOR JAMB 5 BUTT HUNG OR OFFSET PIVOT TRANSOM BAR BUTT HUNG OR OFFSET PIVOT WITH LCN CONCEALED OVER HEAD CLOSER OR SURFACE CLOSER ADMD081EN kawneer.com © Kawneer Company, Inc., 2013 3/4" (19.1) TYP. Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. BUTT HUNG OR OFFSET PIVOT WITH SINGLE ACTING OFFSET ARM CLOSER © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 2 2-1/2" (63.5) kawneer.com 1" (25.4) 2-1/2" (63.5) Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. MAY, 2016 1600UT System™2 Curtain Wall EC 97911-095 AATM250/425 THERMAL ENTRANCE DETAILS (1" INFILL) SCALE 3" = 1'-0" 1 2 ELEVATION IS NUMBER KEYED TO DETAILS B/H OR O/P BUTT HUNG OR OFFSET PIVOT DOOR JAMB ADMD081EN 1 1" (25.4) TRANSOM BAR BUTT HUNG OR OFFSET PIVOT WITH SURFACE CLOSER OR FLOOR CLOSER 7 ELEVATION IS NUMBER KEYED TO DETAILS B/H OR O/P 1 2 BUTT HUNG OR OFFSET PIVOT DOOR JAMB TRANSOM BAR BUTT HUNG OR OFFSET PIVOT WITH SURFACE CLOSER OR FLOOR CLOSER ADMD081EN kawneer.com © Kawneer Company, Inc., 2013 INSULCLADTM THERMAL ENTRANCE DETAILS (1" INFILL) Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 1600UT System™2 Curtain Wall Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 1" (25.4) 8 EC 97911-095 MAY, 2016 SCALE 3" = 1'-0" 1 2 1" (25.4) © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. MAY, 2016 kawneer.com 1600UT System™2 Curtain Wall EC 97911-095 CORNERS (1" INFILL) SCALE 3" = 1'-0" 90° OUTSIDE CORNER 90° INSIDE CORNER 135° OUTSIDE CORNER 135° INSIDE CORNER 0° TO 5° 0° TO 5° OUTSIDE SPLAYED MULLIONS INSIDE SPLAYED MULLIONS OTHER SPLAY OPTIONS AVAILABLE ADMD081EN 9 0° TO 5° 0° TO 5° 5° TO 15° 5° TO 15° ADMD081EN 15° TO 25° OUTSIDE SPLAYED MULLIONS 15° TO 25° INSIDE SPLAYED MULLIONS kawneer.com © Kawneer Company, Inc., 2013 SPLAYED MULLION OPTIONS Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 1600UT System™2 Curtain Wall Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 10 EC 97911-095 MAY, 2016 SCALE 3" = 1'-0" © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. MAY, 2016 SCALE 3" = 1'-0" kawneer.com 1600UT System™2 Curtain Wall EC 97911-095 WINDOWS GLASSventTM Windows for Curtain Wall HEAD SILL JAMB NOTE: Project-out GLASSvent™ window shown GLASSventTM UT Windows HEAD SILL JAMB ADMD081EN 11 WINDOWS HEAD SILL JAMB ADMD081EN kawneer.com © Kawneer Company, Inc., 2013 1600UT System™2 Curtain Wall Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. SCALE 3" = 1'-0" Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 12 EC 97911-095 MAY, 2016 AA™900 Thermal Windows NOTE: AA™6400 vent can be accommodated. Contact your Kawneer representative for other options. © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 6A 4 6 6B ELEVATION IS NUMBER KEYED TO DETAILS 6 7 1" INFILL ADAPTER kawneer.com 2-1/2" (63.5) MAY, 2016 1600UT System™2 Curtain Wall EC 97911-095 1-3/4" INFILL DETAILS SCALE 3" = 1'-0" 1 1A 1 2 2A 3 7A OPTIONAL FIBERGLASS PRESSURE PLATE 6A 6B 1" INFILL ADAPTER OPEN BACK JAMB 7A 7B STEEL REINFORCING AS REQUIRED ADMD081EN 1A 7 7B TUBE HORIZONTAL 5 2 6-3/4" (171.4) 8-1/4" (209.5) OPEN BACK HORIZONTAL 2A 3 4 5 13 14 1600UT System™2 Curtain Wall MAY, 2016 NON-THERMAL ENTRANCE DETAILS (1-3/4" INFILL) EC 97911-095 SCALE 3" = 1'-0" 3 4 6 1 1-3/4" (50.8) 2 1/8" (3.2) 2-1/2" (63.5) 5 TRANSOM BAR B/H OR O/P C/H BUTT HUNG OR OFFSET PIVOT WITH SURFACE CLOSER OR FLOOR CLOSER B/H OR O/P DOOR JAMB 2 1A 1/8" (3.2) 2-1/2" (63.5) ELEVATION IS NUMBER KEYED TO DETAILS 1-3/4" (50.8) BUTT HUNG OR OFFSET PIVOT Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 1 1A TRANSOM BAR BUTT HUNG OR OFFSET PIVOT WITH SINGLE ACTING OFFSET ARM CLOSER CENTER HUNG 1-3/4" (50.8) 4 3 TRANSOM BAR CENTER HUNG WITH CONCEALED OVERHEAD OR FLOOR CLOSER 2-1/2" (63.5) 3/4" (19.1) TYP. 6 5 DOOR JAMB BUTT HUNG OR OFFSET PIVOT TRANSOM BAR BUTT HUNG OR OFFSET PIVOT WITH LCN CONCEALED OVER HEAD CLOSER OR SURFACE CLOSER ADMD081EN kawneer.com © Kawneer Company, Inc., 2013 1/8" (3.2) DOOR JAMB Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 2-1/2" (63.5) 3/4" (19.1) TYP. © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 1" (25.4) Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 2 2-1/2" (63.5) kawneer.com 2-1/2" (63.5) MAY, 2016 1600UT System™2 Curtain Wall EC 97911-095 AATM250/425 THERMAL ENTRANCE DETAILS (1-3/4" INFILL) SCALE 3" = 1'-0" 1 2 ELEVATION IS NUMBER KEYED TO DETAILS B/H OR O/P BUTT HUNG OR OFFSET PIVOT DOOR JAMB ADMD081EN 1 1" (25.4) TRANSOM BAR BUTT HUNG OR OFFSET PIVOT WITH SURFACE CLOSER OR FLOOR CLOSER 15 SCALE 3" = 1'-0" ELEVATION IS NUMBER KEYED TO DETAILS B/H OR O/P 2-1/2" (63.5) BUTT HUNG OR OFFSET PIVOT DOOR JAMB ADMD081EN 1 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. INSULCLADTM THERMAL ENTRANCE DETAILS (1-3/4"" INFILL) TRANSOM BAR BUTT HUNG OR OFFSET PIVOT WITH SURFACE CLOSER OR FLOOR CLOSER kawneer.com © Kawneer Company, Inc., 2013 2 2-1/2" (63.5) 1600UT System™2 Curtain Wall Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 1" (25.4) 16 EC 97911-095 MAY, 2016 1 2 1" (25.4) © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. MAY, 2016 kawneer.com 1600UT System™2 Curtain Wall EC 97911-095 CORNERS (1-3/4" INFILL) SCALE 3" = 1'-0" 90° OUTSIDE CORNER 90° INSIDE CORNER 135° OUTSIDE CORNER 135° INSIDE CORNER 0° TO 5° 0° TO 5° OUTSIDE SPLAYED MULLIONS INSIDE SPLAYED MULLIONS OTHER SPLAY OPTIONS AVAILABLE ADMD081EN 17 SCALE 3" = 1'-0" HEAD SILL JAMB HEAD SILL JAMB NOTE: AA™6400 vent can be accommodated. Contact your Kawneer representative for other options. ADMD081EN kawneer.com © Kawneer Company, Inc., 2013 WINDOWS Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 1600UT System™2 Curtain Wall Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 18 EC 97911-095 MAY, 2016 GLASSventTM UT Windows AA™900 Thermal Windows © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. kawneer.com 6 NOTE: 6" SYSTEM SHOWN, 7-1/2" SYSTEM SIMILAR 1 2 JAMB MULLION AT SPANDREL (With vapor barrier tie-in) MULLION AT SPANDREL 1/2" (12.7) 5 3/8" (9.5) 2-1/2" (63.5) 3/8" (9.5) D.L.O. MULLION LENGTH CONSTRUCTION JOINT 1/2" (12.7) MAX (ALLOWS +/-1/4" MOVEMENT) 2 D.L.O. 1 MULLION LENGTH Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. MAY, 2016 1600UT System™2 Curtain Wall EC 97911-095 BACKPAN DETAILS (1" INFILL) SCALE 3" = 1'-0" 3 4 3 HEAD TRANSOM AT PARAPET FLASHING 4 ELEVATION IS NUMBER KEYED TO DETAILS EXPANSION JOINT 5 TYPICAL DEADLOAD ANCHOR 6 TRANSOM – SPANDREL OVER VISION ADMD081EN 19 3 4 5 HEAD TRANSOM AT PARAPET FLASHING 1 2 6 4 ELEVATION IS NUMBER KEYED TO DETAILS EXPANSION JOINT 1 JAMB MULLION AT SPANDREL 2 5 MULLION AT SPANDREL TYPICAL DEADLOAD ANCHOR 6 TRANSOM – SPANDREL OVER VISION ADMD081EN kawneer.com © Kawneer Company, Inc., 2013 BACKPAN DETAILS (1-3/4" INFILL) Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 1600UT System™2 Curtain Wall Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 20 EC 97911-095 MAY, 2016 SCALE 3" = 1'-0" 3 NOTE: 6" SYSTEM SHOWN, 7-1/2" SYSTEM SIMILAR 1600UT System™2 Curtain Wall MAY, 2016 EC 97911-095 21 MISCELLANEOUS FRAMING SCALE 3" = 1'-0" 4-3/4" (120.7) 3" (76.2) 2-1/2" (63.5) 1-1/4" (31.8) OPTIONAL DEEP COVERS 2-1/2" (63.5) 10-1/2" (266.7) 2-1/2" (63.5) Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. Architects – Most extrusion and window types illustrated in this catalog are standard products for Kawneer. These concepts have been expanded and modified to afford you design freedom. Some miscellaneous details are non-standard and are intended to demonstrate how the system can be modified to expand design flexibility. Please contact your Kawneer representative for further assistance. 2-1/2" (63.5) DEEP MULLION 1-3/16" (30.1) 2" (50.8) OPTIONAL BULL NOSE COVERS 3-1/4" (82.6) 2-1/2" (63.5) 2-1/2" (63.5) VARIES 2-1/2" (63.5) DOUBLE MULLION VENEER SYSTEM © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 2-3/4" (69.7) 069263 GYPSUM BOARD TRIM STOOL TRIM OPTIONS: 069264 - 2-3/4" (69.9) 069265 - 4-1/2" (114.3) 069266 - 5" (127.0) 069267 - 6-1/8" (155.6) 069268 - 6-3/4" (171.4) NOTE: STOOL TRIMS REQUIRE 069271 TRIM CLIP PACKAGE INTERIOR STOOL TRIM kawneer.com ADMD081EN THERMAL PERIMETER PRESSURE PLATE 7-3/4" (305.6) 6-1/4" (158.8) 2-1/2" (63.5) 1-5/16" INFILL DETAILS 6-1/4" (158.8) 7-3/4" (305.6) 2-1/2" (63.5) ADMD081EN kawneer.com © Kawneer Company, Inc., 2013 MISCELLANEOUS FRAMING Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 2-1/2" (63.5) 7-3/4" (305.6) 6-1/4" (158.8) 1600UT System™2 Curtain Wall Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 2-1/2" (63.5) 7-3/4" (305.6) 6-1/4" (158.8) 22 EC 97911-095 MAY, 2016 1-1/4" INFILL DETAILS © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. MAY, 2016 kawneer.com 1600UT System™2 Curtain Wall EC 97911-095 ANCHORING Actual project conditions will determine specific anchor design. Details on this page are for reference only. 1" (25.4) ANCHORING TO FLOOR SLAB NOTE: 1-3/4" triple glazing similar. 1" (25.4) ANCHORING TO SUPPORT STEEL NOTE: 1-3/4" triple glazing similar. ADMD081EN 23 1" (25.4) ANCHORING TO HORIZONTAL STRUCTURAL STEEL 1" (25.4) ANCHORING TO VERTICAL STRUCTURAL STEEL NOTE: 1-3/4" triple glazing similar. ADMD081EN kawneer.com © Kawneer Company, Inc., 2013 ANCHORING Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 1600UT System™2 Curtain Wall Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 24 EC 97911-095 MAY, 2016 Actual project conditions will determine specific anchor design. Details on this page are for reference only. NOTE: 1-3/4" triple glazing similar. MAY, 2016 1600UT System™2 Curtain Wall EC 97911-095 25 WIND LOAD / DEADLOAD CHARTS Mullions are designed for deflection limitations in accordance with AAMA TIR-A11 of L/175 up to 13'-6" and L/240 +1/4" above 13'-6". These curves are for mullions WITH HORIZONTALS and are based on engineering calculations for stress and deflection. Allowable wind load stress for ALUMINUM 15,152 psi (104MPa), STEEL 30,000 psi (207MPa). Charted curves, in all cases are for the limiting value. Wind load charts contained herein are based upon nominal wind load utilized in allowable stress design. A conversion from Load Resistance Factor Design (LRFD) is provided. To convert ultimate wind loads to nominal loads, multiply ultimate wind loads by a factor of 0.6 per ASCE/SEI 7. A 4/3 increase in allowable stress has not been used to develop these curves. For special situations not covered by these curves, contact your Kawneer representative for additional information. DEADLOAD CHARTS Horizontal or deadload limitations are based upon 1/8" (3.2), maximum allowable deflection at the center of an intermediate horizontal member. The accompanying charts are calculated for 1" (25.4) thick insulating glass or 1-3/4" (44.5) thick glass supported on two setting blocks placed at the loading points shown. © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. WIND LOAD CHARTS kawneer.com ADMD081EN 1600UT System™2 Curtain Wall MAY, 2016 EC 97911-095 WIND LOAD CHARTS (S.S.G.) A= B= C= D= E= METERS 1.5 2 7 23 22 6.5 21 20 METERS .5 2 9 28 8.5 27 6 8 26 5.5 25 4 13 12 3.5 11 162025 A 10 C 8 7 7.5 24 A 7 23 B 22 C 21 6.5 20 6 D 19 E 18 5.5 17 5 16 2.5 D E 6 I = 2.860(119.04 x 10 ) S = 1.482(24.28 x 103) 4 3 B 9 MULLION HEIGHT EQUAL EQUAL 4.5 14 3-3/4" (95.3) 15 METERS 5 16 MULLION HEIGHT 17 MULLION HEIGHT IN FEET 18 MULLION HEIGHT IN FEET 1.5 29 19 5 1 30 15 4.5 14 2 4 13 0 1 2 3 4 5 6 7 12 8 0 MULLION CENTERS IN FEET 1 2 SINGLE SPAN METERS .5 1 1.5 3 4 5 6 7 8 MULLION CENTERS IN FEET TWIN SPAN 2 METERS .5 7 23 1 1.5 2 30 9 22 29 6.5 20 28 6 19 5.5 4 13 12 3.5 11 A 162026 B I = 3.660(152.34 x 104) S = 1.840(30.15 x 103) 10 9 8 C E D 7 3 2.5 MULLION HEIGHT IN FEET 4.5 14 MULLION HEIGHT EQUAL EQUAL 15 3-3/4" (95.3) 5 MULLION HEIGHT 17 16 A 25 METERS MULLION HEIGHT IN FEET 8 26 18 7.5 24 23 7 B 22 6.5 21 C 20 E 19 6 D 5.5 18 17 5 16 15 4.5 14 2 6 5 8.5 27 4 13 0 1 2 3 4 5 6 7 METERS 21 12 8 MULLION CENTERS IN FEET 0 1 2 3 4 5 6 7 8 MULLION CENTERS IN FEET ADMD081EN kawneer.com © Kawneer Company, Inc., 2013 1 TWIN SPAN LRFD Ultimate Design Load 33 PSF (1580) 50 PSF (2400) 67 PSF (3200) 83 PSF (4000) 100 PSF (4800) Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. .5 Allowable Stress Design Load 20 PSF (960) 30 PSF (1440) 40 PSF (1920) 50 PSF (2400) 60 PSF (2880) Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. SINGLE SPAN METERS 26 1600UT System™2 Curtain Wall MAY, 2016 EC 97911-095 WIND LOAD CHARTS (S.S.G.) SINGLE SPAN A= B= C= D= E= METERS 1 1.5 2 7 23 6.5 21 20 TWIN SPAN LRFD Ultimate Design Load 33 PSF (1580) 50 PSF (2400) 67 PSF (3200) 83 PSF (4000) 100 PSF (4800) METERS .5 2 9 A 28 8.5 27 8 26 5.5 4 A 12 3.5 B 11 C 10 162027 7 C 7 23 D E 22 6.5 21 20 6 19 5.5 18 5 16 I = 6.424(267.38 x 104) S = 2.385(39.08 x 103) 2.5 8 7.5 24 17 3 D E 9 MULLION HEIGHT IN FEET 13 MULLION HEIGHT EQUAL EQUAL 4.5 14 5-1/4" (133.4) 15 METERS 5 MULLION HEIGHT 17 16 B 25 15 4.5 14 2 4 13 6 0 1 2 3 4 5 6 7 12 8 0 1 2 SINGLE SPAN 1 4 5 6 7 8 TWIN SPAN METERS .5 3 MULLION CENTERS IN FEET MULLION CENTERS IN FEET METERS 1.5 .5 2 7 23 1 1.5 2 30 9 22 29 6.5 20 28 6 B 26 5.5 25 A 13 4 B 12 C 11 3.5 E D 10 MULLION HEIGHT EQUAL EQUAL 4.5 14 5-1/4" (133.4) 15 METERS 5 16 MULLION HEIGHT 17 162028 2.5 8 7 8 C 7.5 24 E D 23 7 22 6.5 21 20 6 19 5.5 18 17 3 9 MULLION HEIGHT IN FEET 18 MULLION HEIGHT IN FEET 8.5 27 19 5 16 I = 8.088(336.64 x 10 ) S = 2.930(48.01 x 103) 4 15 4.5 14 2 4 13 6 5 A 0 1 2 3 4 5 6 7 12 8 MULLION CENTERS IN FEET kawneer.com 0 1 2 3 4 5 6 7 MULLION CENTERS IN FEET ADMD081EN 8 METERS 21 © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 1.5 29 6 18 5 1 30 19 MULLION HEIGHT IN FEET Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 22 Allowable Stress Design Load 20 PSF (960) 30 PSF (1440) 40 PSF (1920) 50 PSF (2400) 60 PSF (2880) METERS .5 27 1600UT System™2 Curtain Wall MAY, 2016 EC 97911-095 WIND LOAD CHARTS (S.S.G.) 162028 W/162300 METERS 1 1.5 2 30 9 29 28 8.5 SINGLE SPAN LRFD Ultimate Design Load 33 PSF (1580) 50 PSF (2400) 67 PSF (3200) 83 PSF (4000) 100 PSF (4800) 162028 W/162301 METERS .5 2 9 28 8.5 27 25 25 MULLION HEIGHT IN FEET 7.5 MULLION HEIGHT 24 22 6.5 21 20 METERS 7 23 6 19 A 5.5 18 17 B 162028 W/162301 162028 W/162300 5 16 Ia = 8.088(336.64 x 10 ) Sa = 2.930(48.01 x 103) Is = 3.805(158.37 x 104) Ss = 1.669(27.35 x 103) C 4.5 D 14 E 13 0 1 2 3 5 6 7 7 23 22 6.5 21 20 18 C 1.5 4.5 E 14 4 13 12 8 0 1 2 3 4 5 6 7 8 MULLION CENTERS IN FEET SINGLE SPAN 162028 W/162301/302/303 162028 W/162301/302 1 5 D 15 SINGLE SPAN METERS 5.5 B MULLION CENTERS IN FEET .5 6 A 19 16 4 4 4 7.5 24 17 Ia = 8.088(336.64 x 10 ) Sa = 2.930(48.01 x 103) Is = 5.684(236.59 x 104) Ss = 2.493(40.85 x 103) 4 15 8 26 METERS .5 2 1 1.5 2 30 30 9 9 29 29 28 28 8.5 8 26 25 25 7.5 MULLION HEIGHT IN FEET 7.5 22 6.5 21 A 20 METERS 7 23 6 19 B 18 5.5 C 17 16 E 5 D 162028 W/162301/302 162028 W/162301/302/303 Ia = 8.088(336.64 x 10 ) Sa = 2.930(48.01 x 103) Is = 7.893(328.53 x 104) Ss = 3.462(56.73 x 103) Ia = 8.088(336.64 x 10 ) Sa = 2.930(48.01 x 103) Is = 9.347(389.05 x 104) Ss = 4.100(67.19 x 103) 4 15 4.5 14 1 2 3 4 5 6 7 24 7 23 22 A 21 6.5 20 6 B 19 C 5.5 18 D E 17 5 16 4 4 13 0 5-1/4" (133.4) MULLION HEIGHT 24 METERS 8 26 MULLION HEIGHT IN FEET 8.5 27 27 12 METERS 8 26 MULLION HEIGHT IN FEET 1.5 29 27 12 1 30 15 4.5 14 4 13 12 8 MULLION CENTERS IN FEET 0 1 2 3 4 5 6 7 8 MULLION CENTERS IN FEET ADMD081EN kawneer.com © Kawneer Company, Inc., 2013 .5 A= B= C= D= E= Allowable Stress Design Load 20 PSF (960) 30 PSF (1440) 40 PSF (1920) 50 PSF (2400) 60 PSF (2880) Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. SINGLE SPAN Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 28 1600UT System™2 Curtain Wall MAY, 2016 EC 97911-095 WIND LOAD CHARTS (S.S.G.) SINGLE SPAN 162028 W/162300 A= B= C= D= E= METERS 1 1.5 2 28 8.5 8 26 25 SINGLE SPAN LRFD Ultimate Design Load 33 PSF (1580) 50 PSF (2400) 67 PSF (3200) 83 PSF (4000) 100 PSF (4800) 162028 W/162301 METERS .5 2 9 29 28 8.5 27 7.5 A 26 MULLION HEIGHT IN FEET 23 7 MULLION HEIGHT 22 20 6 A 19 18 5.5 B 17 C 16 8-1/4" (209.6) 6.5 21 METERS 5 4 1 2 3 7 C 22 6.5 21 D 20 E 6 19 5.5 5 16 13 0 23 7.5 17 4.5 E 14 B 24 18 D 15 25 8 4 5 6 7 15 162076 W/162363 162076 8 I = 31.174(1,297.56 x 104) S = 7.452(122.12 x 103) MULLION CENTERS IN FEET 14 4.5 0 1 2 3 4 5 6 7 Ia = 31.174(1,297.56 x 10 ) Sa = 7.452(122.12 x 103) Is = 17.600(732.56 x 104) Ss = 4.732(77.54 x 103) SINGLE SPAN SINGLE SPAN 162028 W/162301/302 162028 W/162301/302/303 .5 1 8 MULLION CENTERS IN FEET 4 METERS 1.5 2 .5 30 1 1.5 2 30 9 9 29 29 A 28 25 7.5 24 D 23 7 E 22 6.5 21 20 METERS MULLION HEIGHT IN FEET 8 C 6 19 5.5 18 17 5 16 15 14 4.5 0 1 2 3 4 5 6 7 MULLION CENTERS IN FEET kawneer.com 8 B 26 MULLION HEIGHT IN FEET B 26 8.5 27 MULLION HEIGHT 27 A 28 8.5 25 8 7.5 C 24 D 23 7 E 22 6.5 21 20 6 19 5.5 18 162076 W/162363/364 162076 W/162363/364/365 Ia = 31.174(1,297.56 x 104) Sa = 7.452(122.12 x 103) Is = 26.033(1,083.57 x 104) Ss = 7.000(114.71 x 103) Ia = 31.174(1,297.56 x 104) Sa = 7.452(122.12 x 103) Is = 32.432(1,349.92 x 104) Ss = 32.432(531.46 x 103) ADMD081EN 17 5 16 15 14 4.5 0 1 2 3 4 5 6 7 MULLION CENTERS IN FEET 8 METERS MULLION HEIGHT IN FEET 1.5 30 24 12 1 METERS © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 27 Allowable Stress Design Load 20 PSF (960) 30 PSF (1440) 40 PSF (1920) 50 PSF (2400) 60 PSF (2880) METERS .5 29 GLASS HEIGHT IN FEET METERS 0 0 0 0 1 1 2 2 3 3 2 4 4 5 5 METERS 13 13 6 3 6 1 4 6 1 12 12 11 11 3 8 B 7 8 7 7 2 5 4 A 1 2 2 1 1 8 10 3 0 13 13 12 12 11 11 9 3 B 2 6 5 A 1 2 2 1 1 8 0 SPAN IN FEET ADMD081EN 0 0 1 1 2 SPAN IN FEET 7-1/2" (190.5) METERS 2 3 2 3 2 10 9 3 8 7 6 B 4 3 4 171215 4 5 5 6 1 5 4 6 7 7 7 2 5 A 1 171216 METERS 2 10 9 3 8 B 6 2 A 3 1 SPAN IN FEET 8 kawneer.com © Kawneer Company, Inc., 2013 171213 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 6" (152.4) METERS DEADLOAD CHARTS (TUBULAR) Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 9 GLASS HEIGHT IN FEET 1600UT System™2 Curtain Wall METERS 7 GLASS HEIGHT IN FEET 10 METERS 1 METERS GLASS HEIGHT IN FEET 30 EC 97911-095 MAY, 2016 A - 1" GLASS (1/4 POINT LOADING) B - 1" GLASS (1/8 POINT LOADING) 6" (152.4) 171214 8 SPAN IN FEET 7-1/2" (190.5) GLASS HEIGHT IN FEET © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. kawneer.com 6-3/4" (171.5) 171201 0 0 0 0 1 1 2 2 3 3 4 4 5 2 6 5 4 3 5 1 5 4 6 METERS 13 13 1 12 12 11 11 3 7 2 B A 6 7 10 7 6 2 B 3 7 10 8 1 8 3 9 8 A 1 8 SPAN IN FEET ADMD081EN 7 6 2 2 1 1 0 13 13 12 12 11 11 2 2 1 1 0 2 4 3 SPAN IN FEET 0 0 1 1 2 8-1/4" (209.6) METERS 2 3 2 3 4 171203 4 5 6 1 3 SPAN IN FEET 5 6 7 10 7 6 2 5 B 4 A 7 1 8 METERS EC 97911-095 METERS 9 GLASS HEIGHT IN FEET 10 GLASS HEIGHT IN FEET 1 METERS METERS METERS GLASS HEIGHT IN FEET Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. MAY, 2016 1600UT System™2 Curtain Wall 31 DEADLOAD CHARTS (TUBULAR) A - 1-3/4" GLASS (1/4 POINT LOADING) B - 1-3/4" GLASS (1/8 POINT LOADING) 6-3/4" (171.5) 171202 2 9 3 8 5 B A 1 SPAN IN FEET 8 8-1/4" (209.6) 171204 METERS 2 9 3 8 GLASS HEIGHT IN FEET 3 2 1 0 0 A 0 0 1 1 2 2 3 3 4 4 5 5 6 1 5 4 3 6 METERS 2 METERS 13 13 1 12 12 11 11 3 8 6 2 5 4 1 B 7 7 8 10 7 A 0 SPAN IN FEET 13 13 12 12 11 11 9 3 8 6 2 B 1 2 2 1 1 8 0 SPAN IN FEET ADMD081EN 0 0 1 1 2 METERS 2 3 2 3 2 10 9 3 8 7 6 2 5 4 3 2 A B 4 4 5 5 6 1 6 5 4 6 1 7 10 7 2 B 3 7 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 171297 171293 (DOTTED) 171296 171292 (DOTTED) 171297 171293 (DOTTED) 171077 REINF. 171078 REINF. METERS 2 9 3 8 A 1 SPAN IN FEET 8 kawneer.com © Kawneer Company, Inc., 2013 171296 171292 (DOTTED) METERS DEADLOAD CHARTS (OPENBACK) Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 9 GLASS HEIGHT IN FEET 1600UT System™2 Curtain Wall METERS 7 GLASS HEIGHT IN FEET 10 METERS 1 METERS GLASS HEIGHT IN FEET 32 EC 97911-095 MAY, 2016 A - 1" GLASS (1/4 POINT LOADING) B - 1" GLASS (1/8 POINT LOADING) 1 SPAN IN FEET 8 GLASS HEIGHT IN FEET © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. kawneer.com 9 0 0 3 8 6 2 5 4 3 B 2 1 0 0 1 1 2 2 3 3 4 4 5 5 6 1 7 6 4 3 6 7 10 B 7 2 A GLASS HEIGHT IN FEET 171294 171290 (DOTTED) METERS 2 13 13 1 12 12 11 11 10 1 A 8 9 3 8 5 1 8 SPAN IN FEET ADMD081EN 7 6 0 13 13 12 12 11 11 2 2 1 1 0 2 3 2 SPAN IN FEET 0 0 1 1 2 METERS 2 3 2 3 4 4 5 6 1 SPAN IN FEET 5 6 7 10 8 7 B 6 2 5 4 3 A 7 1 8 METERS EC 97911-095 METERS 7 GLASS HEIGHT IN FEET 10 METERS 1 METERS GLASS HEIGHT IN FEET Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. MAY, 2016 1600UT System™2 Curtain Wall 33 DEADLOAD CHARTS (OPENBACK) A - 1" GLASS (1/4 POINT LOADING) B - 1" GLASS (1/8 POINT LOADING) 171295 171291 (DOTTED) METERS 2 9 3 8 5 4 B 1 1 A SPAN IN FEET 8 171294 171290 (DOTTED) 171295 171291 (DOTTED) 171077 REINF. 171078 REINF. METERS 2 9 3 GLASS HEIGHT IN FEET 3 2 1 0 0 0 0 1 1 2 2 3 3 4 4 5 5 6 1 5 4 3 6 METERS 2 METERS 13 13 1 12 12 11 11 3 8 6 2 5 4 1 B A 7 7 8 10 7 A 0 SPAN IN FEET 13 13 12 12 11 11 9 3 8 2 6 B 1 2 2 1 1 8 0 SPAN IN FEET ADMD081EN 0 0 1 1 2 METERS 2 3 2 3 2 10 9 3 8 7 6 2 5 4 3 2 A B 1 4 4 5 6 1 5 4 5 6 7 10 7 6 2 B 3 7 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 171295 171291 (DOTTED) 171294 171290 (DOTTED) 171295 171291 (DOTTED) 171077 REINF. 171078 REINF. METERS 2 9 3 8 A 1 SPAN IN FEET 8 kawneer.com © Kawneer Company, Inc., 2013 171294 171290 (DOTTED) METERS DEADLOAD CHARTS (OPENBACK) Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 9 GLASS HEIGHT IN FEET 1600UT System™2 Curtain Wall METERS 7 GLASS HEIGHT IN FEET 10 METERS 1 METERS GLASS HEIGHT IN FEET 34 EC 97911-095 MAY, 2016 A - 1-3/4" GLASS (1/4 POINT LOADING) B - 1-3/4" GLASS (1/8 POINT LOADING) 1 SPAN IN FEET 8 1600UT System™2 Curtain Wall MAY, 2016 EC 97911-095 THERMAL CHARTS Generic Project Specific U-factor Example Calculation (Percent of Glass will vary on specific products depending on sitelines) (Based on single bay of Curtain Wall/Window Wall) 2-1/2" Typ. 4'-0" 3'-0" D.L.O. D.L.O. VISION VISION 6'-0" D.L.O. SPANDREL 9'-0" D.L.O. 31'-3" 8'-0" D.L.O. SPANDREL VISION 5'-0" D.L.O. Vision Area Example Glass U-factor = 0.48 Btu/(ft2 · h · °F) Vision Area = 5(9 + 8 + 4) = 105.0 ft2 Total Area (Vision) = 5' 2-1/2" (9' 3-3/4" + 8' 2-1/2" + 4' 2-1/2") = 113.2 ft2 Percentage of Vision Glass = (Vision Area ÷ Total Area)100 = (105.0 ÷ 113.2)100 = 93% © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 2-1/2" Typ. Spandrel Area Example Spandrel R-value = 15 (ft2 · h · °F)/Btu Spandrel Area = 5(6 + 3) = 45.0 ft2 Total Area (Spandrel) = 5' 2-1/2" (6' 2-1/2" + 3' 3-3/4") = 49.6 ft2 Percent of Spandrel kawneer.com = (Spandrel Area ÷ Total Area)100 = (45.0 ÷ 49.6)100 = 91% ADMD081EN 35 36 1600UT System™2 Curtain Wall MAY, 2016 THERMAL CHARTS EC 97911-095 Vision Area Chart System U-factor vs Percent of Vision Area E IGN PL S M E A D EX OR F T COG U-factor 0.53 0.50 0.40 0.30 ) 0.48 0.46 0.44 0.42 0.40 0.38 0.36 0.34 0.32 0.30 0.28 0.26 0.24 0.22 0.20 0.60 Btu h·ft 2·°F System U-factor O (N 0.70 93% 0.20 95 85 90 75 80 70 Vision Area / Total Area (%) Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 0.80 System U-factor vs Percent of Spandrel Area Spandrel R-value E IGN PL S M E A D EX OR F O 0.50 T 3.00 4.00 5.00 0.21 0.20 0.10 91% 95 0.30 ) 11.00 15.00 19.00 30.00 0.40 Btu h·ft 2·°F System U-factor (N 2.00 0.60 90 85 80 75 70 Spandrel Area / Total Area (%) Based on a single curtain wall bay of 91% spandrel and center of spandrel R-value of 15, system U-factor is equal to 0.21 Btu/(h·ft 2·°F) ADMD081EN kawneer.com © Kawneer Company, Inc., 2013 Spandrel Area Chart Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Based on a single curtain wall bay of 93% vision glass and center of glass U-factor of 0.48, System U-factor is equal to 0.53 Btu/(h·ft 2·°F) 1600UT System™2 Curtain Wall MAY, 2016 EC 97911-095 THERMAL CHARTS Note: Values in parentheses are metric. COG=Center of Glass. Charts are generated per AAMA 507. 1" GLAZING WITH ALUMINUM PRESSURE PLATE System U-Factor (Btu/h·ft2·°F) Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. System U-Factor for Vision Glass COG U-factor 0.47 (2.67) 0.46 (2.61) 0.44 (2.50) 0.42 (2.39) 0.38 (2.16) 0.36 (2.05) 0.34 (1.93) 0.32 (1.82) 0.30 (1.71) 0.28 (1.59) 0.26 (1.48) 0.24 (1.37) 0.22 (1.25) 0.20 (1.14) 0.18 (1.02) 0.16 (0.91) © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 0.40 (2.27) 0.14 (0.79) 0.12 (0.68) 0.10 (0.57) Vision Area / Total Area (%) Notes for System U-Factor, SHGC and VT charts: For glass values that are not listed, linear interpolation is permitted. Glass properties are based on center of glass values (winter conditions) and are obtained from your glass supplier. kawneer.com ADMD081EN 37 COG VT System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area System Visible Transmittance (VT) vs Percent of Vision Area Charts are generated per AAMA 507. Vision Ares / Total Area (%) ADMD081EN kawneer.com © Kawneer Company, Inc., 2013 THERMAL CHARTS Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 1600UT System™2 Curtain Wall Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. System SHGC COG SHGC System VT 38 EC 97911-095 MAY, 2016 1" GLAZING WITH ALUMINUM PRESSURE PLATE Vision Area / Total Area (%) Charts are generated per AAMA 507. 1600UT System™2 Curtain Wall MAY, 2016 EC 97911-095 THERMAL PERFORMANCE MATRIX (NFRC SIZE) 1" GLAZING WITH ALUMINUM PRESSURE PLATE Thermal Transmittance 1 (BTU/hr • ft 2 • °F) Overall U-Factor 4 0.47 0.53 0.46 0.52 0.44 0.50 0.42 0.49 0.40 0.47 0.38 0.45 0.36 0.44 0.34 0.42 0.32 0.40 0.30 0.39 0.28 0.37 0.26 0.35 0.24 0.33 0.22 0.32 0.20 0.30 0.18 0.28 0.16 0.26 0.14 0.24 0.12 0.23 0.10 0.21 NOTE:For glass values that are not listed, linear interpolation is permitted. 1. 2. 3. 4. SHGC Matrix 2 © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. Glass U-Factor 3 kawneer.com 39 U-Factors are determined in accordance with NFRC 100. SHGC and VT values are determined in accordance with NFRC 200. Glass properties are based on center of glass values and are obtained from your glass supplier. Overall U-Factor, SHGC, and VT Matricies are based on the standard NFRC specimen size of 2000mm wide by 2000mm high (78-3/4" by 78-3/4"). Visible Transmittance 2 Glass SHGC 3 Overall SHGC 4 Glass VT 3 Overall VT 4 0.75 0.72 0.75 0.68 0.70 0.68 0.70 0.63 0.65 0.63 0.65 0.59 0.60 0.59 0.60 0.54 0.55 0.54 0.55 0.50 0.50 0.50 0.50 0.45 0.45 0.45 0.45 0.41 0.40 0.41 0.40 0.36 0.35 0.36 0.35 0.32 0.30 0.32 0.30 0.27 0.25 0.27 0.25 0.23 0.20 0.23 0.20 0.18 0.15 0.18 0.15 0.14 0.10 0.14 0.10 0.09 0.05 0.09 0.05 0.05 ADMD081EN 40 1600UT System™2 Curtain Wall MAY, 2016 EC 97911-095 THERMAL CHARTS Note: Values in parentheses are metric. COG=Center of Glass. Charts are generated per AAMA 507. 1" GLAZING WITH FIBERGLASS PRESSURE PLATE 0.47 (2.67) 0.46 (2.61) 0.44 (2.50) 0.42 (2.39) 0.40 (2.27) 0.38 (2.16) 0.36 (2.05) 0.34 (1.93) 0.32 (1.82) 0.30 (1.71) 0.28 (1.59) 0.26 (1.48) 0.24 (1.37) 0.22 (1.25) 0.20 (1.14) 0.18 (1.02) 0.16 (0.91) 0.14 (0.79) 0.12 (0.68) 0.10 (0.57) Vision Area / Total Area (%) Notes for System U-Factor, SHGC and VT charts: For glass values that are not listed, linear interpolation is permitted. Glass properties are based on center of glass values (winter conditions) and are obtained from your glass supplier. ADMD081EN kawneer.com © Kawneer Company, Inc., 2013 COG U-factor Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. System U-Factor (Btu/h·ft2·°F) Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. System U-Factor for Vision Glass System VT © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. System SHGC Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. MAY, 2016 COG SHGC COG VT kawneer.com 1600UT System™2 Curtain Wall EC 97911-095 Vision Ares / Total Area (%) Charts are generated per AAMA 507. ADMD081EN 41 THERMAL CHARTS 1" GLAZING WITH FIBERGLASS PRESSURE PLATE System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area Vision Area / Total Area (%) Charts are generated per AAMA 507. System Visible Transmittance (VT) vs Percent of Vision Area 1600UT System™2 Curtain Wall MAY, 2016 EC 97911-095 THERMAL PERFORMANCE MATRIX (NFRC SIZE) Overall U-Factor 4 0.47 0.53 0.46 0.52 0.44 0.50 0.42 0.48 0.40 0.47 0.38 0.45 0.36 0.43 0.34 0.41 0.32 0.40 0.30 0.38 0.28 0.36 0.26 0.35 0.24 0.33 0.22 0.31 0.20 0.30 0.18 0.27 0.16 0.26 0.14 0.24 0.12 0.22 0.10 0.20 NOTE:For glass values that are not listed, linear interpolation is permitted. 1. 2. 3. 4. SHGC Matrix 2 U-Factors are determined in accordance with NFRC 100. SHGC and VT values are determined in accordance with NFRC 200. Glass properties are based on center of glass values and are obtained from your glass supplier. Overall U-Factor, SHGC, and VT Matricies are based on the standard NFRC specimen size of 2000mm wide by 2000mm high (78-3/4" by 78-3/4"). Visible Transmittance 2 Glass SHGC 3 Overall SHGC 4 Glass VT 3 Overall VT 4 0.75 0.72 0.75 0.68 0.70 0.68 0.70 0.63 0.65 0.63 0.65 0.59 0.60 0.59 0.60 0.54 0.55 0.54 0.55 0.50 0.50 0.50 0.50 0.45 0.45 0.45 0.45 0.41 0.40 0.41 0.40 0.36 0.35 0.36 0.35 0.32 0.30 0.32 0.30 0.27 0.25 0.27 0.25 0.23 0.20 0.23 0.20 0.18 0.15 0.18 0.15 0.14 0.10 0.14 0.10 0.09 0.05 0.09 0.05 0.05 ADMD081EN kawneer.com © Kawneer Company, Inc., 2013 Glass U-Factor 3 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 1" GLAZING WITH FIBERGLASS PRESSURE PLATE Thermal Transmittance 1 (BTU/hr • ft 2 • °F) Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 42 1600UT System™2 Curtain Wall MAY, 2016 EC 97911-095 THERMAL CHARTS Note: Values in parentheses are metric. COG=Center of Glass. Charts are generated per AAMA 507. 1-3/4" GLAZING WITH ALUMINUM PRESSURE PLATE System U-Factor (Btu/h·ft2·°F) Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. System U-Factor for Vision Glass COG U-factor 0.32 (1.82) 0.28 (1.59) 0.26 (1.48) 0.24 (1.37) 0.22 (1.25) 0.20 (1.14) 0.18 (1.02) 0.16 (0.91) 0.14 (0.79) © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 0.30 (1.71) 0.12 (0.68) 0.10 (0.57) 0.08 (0.45) Vision Area / Total Area (%) Notes for System U-Factor, SHGC and VT charts: For glass values that are not listed, linear interpolation is permitted. Glass properties are based on center of glass values (winter conditions) and are obtained from your glass supplier. kawneer.com ADMD081EN 43 COG VT System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area System Visible Transmittance (VT) vs Percent of Vision Area Vision Ares / Total Area (%) Charts are generated per AAMA 507. ADMD081EN kawneer.com © Kawneer Company, Inc., 2013 THERMAL CHARTS Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 1600UT System™2 Curtain Wall Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. System SHGC COG SHGC System VT 44 EC 97911-095 MAY, 2016 1-3/4" GLAZING WITH ALUMINUM PRESSURE PLATE Vision Area / Total Area (%) Charts are generated per AAMA 507. 1600UT System™2 Curtain Wall MAY, 2016 EC 97911-095 THERMAL PERFORMANCE MATRIX (NFRC SIZE) 1-3/4" GLAZING WITH ALUMINUM PRESSURE PLATE Thermal Transmittance 1 (BTU/hr • ft 2 • °F) Overall U-Factor 4 0.32 0.39 0.30 0.37 0.28 0.36 0.26 0.34 0.24 0.32 0.22 0.30 0.20 0.29 0.18 0.27 0.16 0.25 0.14 0.23 0.12 0.22 0.10 0.20 0.08 0.18 NOTE:For glass values that are not listed, linear interpolation is permitted. 1. 2. 3. 4. SHGC Matrix 2 © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. Glass U-Factor 3 kawneer.com 45 U-Factors are determined in accordance with NFRC 100. SHGC and VT values are determined in accordance with NFRC 200. Glass properties are based on center of glass values and are obtained from your glass supplier. Overall U-Factor, SHGC, and VT Matricies are based on the standard NFRC specimen size of 2000mm wide by 2000mm high (78-3/4" by 78-3/4"). Visible Transmittance 2 Glass SHGC 3 Overall SHGC 4 Glass VT 3 Overall VT 4 0.75 0.68 0.75 0.67 0.70 0.64 0.70 0.63 0.65 0.59 0.65 0.58 0.60 0.55 0.60 0.54 0.55 0.50 0.55 0.49 0.50 0.46 0.50 0.45 0.45 0.41 0.45 0.40 0.40 0.37 0.40 0.36 0.35 0.32 0.35 0.31 0.30 0.28 0.30 0.27 0.25 0.24 0.25 0.22 0.20 0.19 0.20 0.18 0.15 0.15 0.15 0.13 0.10 0.10 0.10 0.09 0.05 0.06 0.05 0.04 ADMD081EN 46 1600UT System™2 Curtain Wall MAY, 2016 EC 97911-095 THERMAL CHARTS Note: Values in parentheses are metric. COG=Center of Glass. Charts are generated per AAMA 507. 1-3/4" GLAZING WITH FIBERGLASS PRESSURE PLATE 0.32 (1.82) 0.30 (1.71) 0.28 (1.59) 0.26 (1.48) 0.24 (1.37) 0.22 (1.25) 0.20 (1.14) 0.18 (1.02) 0.16 (0.91) 0.14 (0.79) 0.12 (0.68) 0.10 (0.57) 0.08 (0.45) Vision Area / Total Area (%) Notes for System U-Factor, SHGC and VT charts: For glass values that are not listed, linear interpolation is permitted. Glass properties are based on center of glass values (winter conditions) and are obtained from your glass supplier. ADMD081EN kawneer.com © Kawneer Company, Inc., 2013 COG U-factor Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. System U-Factor (Btu/h·ft2·°F) Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. System U-Factor for Vision Glass System VT © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. System SHGC Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. MAY, 2016 COG SHGC COG VT kawneer.com 1600UT System™2 Curtain Wall EC 97911-095 Vision Ares / Total Area (%) Charts are generated per AAMA 507. ADMD081EN 47 THERMAL CHARTS 1-3/4" GLAZING WITH FIBERGLASS PRESSURE PLATE System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area Vision Area / Total Area (%) Charts are generated per AAMA 507. System Visible Transmittance (VT) vs Percent of Vision Area 1600UT System™2 Curtain Wall MAY, 2016 EC 97911-095 THERMAL PERFORMANCE MATRIX (NFRC SIZE) Overall U-Factor 4 0.32 0.39 0.30 0.37 0.28 0.35 0.26 0.34 0.24 0.32 0.22 0.30 0.20 0.28 0.18 0.27 0.16 0.25 0.14 0.23 0.12 0.21 0.10 0.20 0.08 0.18 NOTE:For glass values that are not listed, linear interpolation is permitted. 1. 2. 3. 4. SHGC Matrix 2 U-Factors are determined in accordance with NFRC 100. SHGC and VT values are determined in accordance with NFRC 200. Glass properties are based on center of glass values and are obtained from your glass supplier. Overall U-Factor, SHGC, and VT Matricies are based on the standard NFRC specimen size of 2000mm wide by 2000mm high (78-3/4" by 78-3/4"). Visible Transmittance 2 Glass SHGC 3 Overall SHGC 4 Glass VT 3 Overall VT 4 0.75 0.68 0.75 0.67 0.70 0.64 0.70 0.63 0.65 0.59 0.65 0.58 0.60 0.55 0.60 0.54 0.55 0.50 0.55 0.49 0.50 0.46 0.50 0.45 0.45 0.41 0.45 0.40 0.40 0.37 0.40 0.36 0.35 0.32 0.35 0.31 0.30 0.28 0.30 0.27 0.25 0.24 0.25 0.22 0.20 0.19 0.20 0.18 0.15 0.15 0.15 0.13 0.10 0.10 0.10 0.09 0.05 0.06 0.05 0.04 ADMD081EN kawneer.com © Kawneer Company, Inc., 2013 Glass U-Factor 3 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 1-3/4" GLAZING WITH FIBERGLASS PRESSURE PLATE Thermal Transmittance 1 (BTU/hr • ft 2 • °F) Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 48