5962-8759405XA SMD

REVISIONS
LTR
DESCRIPTION
DATE (YR-MO-DA)
APPROVED
A
Add device types 02 through 06. Add vendor CAGE 64155. Change CAGE
code to 67268.
88-06-28
M. A. FRYE
B
Add case outline letter 2. Changes in accordance with N.O.R. 5962-R104-94.
94-02-24
M. A. FRYE
C
Add case outline Y. Make changes to 1.2.2, 1.3, 3.2.1, figure 1, and figure 2.
Redrawn. - ro
99-10-14
R. MONNIN
D
Drawing updated to reflect current requirements. - ro
02-07-24
R. MONNIN
E
Add device class V devices and add TABLE IIB. - ro
02-12-06
R. MONNIN
F
Drawing updated as part of 5 year review. -rrp
09-12-14
C. SAFFLE
G
Add device type 61. Add radiation assurance requirements. - ro
14-02-04
C. SAFFLE
CURRENT CAGE CODE 67268
THE ORIGINAL FIRST PAGE OF THIS DRAWING HAS BEEN REPLACED.
REV
SHEET
REV
SHEET
REV STATUS
REV
G
G
G
G
G
G
G
G
G
G
G
G
G
OF SHEETS
SHEET
1
2
3
4
5
6
7
8
9
10
11
12
13
PMIC N/A
PREPARED BY
Charles E. Besore
STANDARD
MICROCIRCUIT
DRAWING
DLA LAND AND MARITIME
COLUMBUS, OHIO 43218-3990
http://www.landandmaritime.dla.mil
CHECKED BY
D. A. DiCenzo
APPROVED BY
THIS DRAWING IS AVAILABLE
FOR USE BY ALL
DEPARTMENTS
AND AGENCIES OF THE
DEPARTMENT OF DEFENSE
AMSC N/A
Nelson Hauck
DRAWING APPROVAL DATE
87-05-29
REVISION LEVEL
G
MICROCIRCUIT, LINEAR, VOLTAGE
REFERENCE, MONOLITHIC SILICON
SIZE
CAGE CODE
A
14933
SHEET
DSCC FORM 2233
APR 97
5962-87594
1 OF 13
5962-E109-14
1. SCOPE
1.1 Scope. This drawing documents two product assurance class levels consisting of high reliability (device class Q and M)
and space application (device class V). A choice of case outlines and lead finishes are available and are reflected in the Part or
Identifying Number (PIN). When available, a choice of Radiation Hardness Assurance (RHA) levels is reflected in the PIN.
1.2 PIN. The PIN is as shown in the following examples.
For device class M and Q:
5962
-
Federal
stock class
designator
\
RHA
designator
(see 1.2.1)
87594
01
X
A
Device
type
(see 1.2.2)
Case
outline
(see 1.2.4)
Lead
finish
(see 1.2.5)
/
\/
Drawing number
For device class V:
5962
R
Federal
stock class
designator
\
RHA
designator
(see 1.2.1)
87594
61
V
Y
A
Device
type
(see 1.2.2)
Device
class
designator
(see 1.2.3)
Case
outline
(see 1.2.4)
Lead
finish
(see 1.2.5)
/
\/
Drawing number
1.2.1 RHA designator. Device classes Q and V RHA marked devices meet the MIL-PRF-38535 specified RHA levels and are
marked with the appropriate RHA designator. Device class M RHA marked devices meet the MIL-PRF-38535, appendix A
specified RHA levels and are marked with the appropriate RHA designator. A dash (-) indicates a non-RHA device.
1.2.2 Device type(s). The device type(s) identify the circuit function as follows:
Device type
Generic number
Circuit function
01
02
03
04
05
06
61
LM185-1.2
LM185-2.5
LM185BX1.2
LM185BX2.5
LM185BY1.2
LM185BY2.5
LM185H-1.2
Voltage reference diode
Voltage reference diode
Voltage reference diode
Voltage reference diode
Voltage reference diode
Voltage reference diode
Voltage reference diode
STANDARD
MICROCIRCUIT DRAWING
DLA LAND AND MARITIME
COLUMBUS, OHIO 43218-3990
DSCC FORM 2234
APR 97
SIZE
5962-87594
A
REVISION LEVEL
G
SHEET
2
1.2.3 Device class designator. The device class designator is a single letter identifying the product assurance level as listed
below. Since the device class designator has been added after the original issuance of this drawing, device classes M and Q
designators will not be included in the PIN and will not be marked on the device.
Device class
Device requirements documentation
M
Vendor self-certification to the requirements for MIL-STD-883 compliant, nonJAN class level B microcircuits in accordance with MIL-PRF-38535, appendix A
Q or V
Certification and qualification to MIL-PRF-38535
1.2.4 Case outline(s). The case outline(s) are as designated in MIL-STD-1835 and as follows:
Outline letter
Descriptive designator
Terminals
X
Y
2
See figure 1
GDFP1-G10
CQCC1-N20
2
10
20
Package style
TO-46 can
Flat pack with gullwing leads
Square leadless chip carrier
1.2.5 Lead finish. The lead finish is as specified in MIL-PRF-38535 for device classes Q and V or MIL-PRF-38535,
appendix A for device class M.
1.3 Absolute maximum ratings. 1/
Reverse current (IR) .................................................................................................. 30 mA
Forward current (IF) ................................................................................................... 10 mA
Maximum power dissipation (PD) .............................................................................. 113 mW
Junction temperature (TJ) .........................................................................................
Lead temperature (soldering 10 seconds):
Cases X and 2 .......................................................................................................
Case Y ...................................................................................................................
Storage temperature range .......................................................................................
Thermal resistance, junction-to-case (θJC):
Case X ...................................................................................................................
Case Y ...................................................................................................................
Case 2 ...................................................................................................................
Thermal resistance, junction-to-ambient (θJA):
Case X ...................................................................................................................
Case Y ...................................................................................................................
Case 2 ...................................................................................................................
+175°C
+300°C
+260°C
-55°C to +150°C
80°C/W
23°C/W
See MIL-STD-1835
440°C/W
194°C/W
100°C/W
1.4 Recommended operating conditions.
Ambient operating temperature range (TA) ............................................................... -55°C to +125°C
________
1/ Stresses above the absolute maximum rating may cause permanent damage to the device. Extended operation at the
maximum levels may degrade performance and affect reliability.
STANDARD
MICROCIRCUIT DRAWING
DLA LAND AND MARITIME
COLUMBUS, OHIO 43218-3990
DSCC FORM 2234
APR 97
SIZE
5962-87594
A
REVISION LEVEL
G
SHEET
3
1.5 Radiation features.
Maximum total dose available (dose rate = 0.010 rads(Si)/s) ........................................ 100 krads(Si) 2/
The manufacturer supplying RHA parts on this drawing has performed a characterization test to demonstrate if the
parts exhibit enhanced low dose rate sensitivity (ELDRS) according to MIL-STD-883 method 1019 paragraph 3.13.11.
These parts have been characterized and observed to be enhanced low dose rate sensitive. However, the characterization
test demonstrated the parts did pass the radiation end point parameter limits under low dose rate conditions according to
MIL-STD-883 method 1019 paragraph 3.13.3.b. The manufacturer will continue to perform low dose rate lot acceptance
testing on each wafer lot or wafer according to method 1019 of MIL-STD-883.
2. APPLICABLE DOCUMENTS
2.1 Government specification, standards, and handbooks. The following specification, standards, and handbooks form a part
of this drawing to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the
solicitation or contract.
DEPARTMENT OF DEFENSE SPECIFICATION
MIL-PRF-38535 - Integrated Circuits, Manufacturing, General Specification for.
DEPARTMENT OF DEFENSE STANDARDS
MIL-STD-883 MIL-STD-1835 -
Test Method Standard Microcircuits.
Interface Standard Electronic Component Case Outlines.
DEPARTMENT OF DEFENSE HANDBOOKS
MIL-HDBK-103 MIL-HDBK-780 -
List of Standard Microcircuit Drawings.
Standard Microcircuit Drawings.
(Copies of these documents are available online at http://quicksearch.dla.mil or from the Standardization Document Order
Desk, 700 Robbins Avenue, Building 4D, Philadelphia, PA 19111-5094.)
2.2 Order of precedence. In the event of a conflict between the text of this drawing and the references cited herein, the text
of this drawing takes precedence. Nothing in this document, however, supersedes applicable laws and regulations unless a
specific exemption has been obtained.
______
2/ For device type 61, these part have been tested and exhibit enhanced low dose rate sensitivity (ELDRS) effects.
Radiation end point limits for the noted parameters are guaranteed for the conditions specified in MIL-STD-883,
method 1019, condition D and paragraph 3.13.3.b.
STANDARD
MICROCIRCUIT DRAWING
DLA LAND AND MARITIME
COLUMBUS, OHIO 43218-3990
DSCC FORM 2234
APR 97
SIZE
5962-87594
A
REVISION LEVEL
G
SHEET
4
3. REQUIREMENTS
3.1 Item requirements. The individual item requirements for device classes Q and V shall be in accordance with
MIL-PRF-38535 and as specified herein or as modified in the device manufacturer's Quality Management (QM) plan. The
modification in the QM plan shall not affect the form, fit, or function as described herein. The individual item requirements for
device class M shall be in accordance with MIL-PRF-38535, appendix A for non-JAN class level B devices and as specified
herein.
3.2 Design, construction, and physical dimensions. The design, construction, and physical dimensions shall be as specified
in MIL-PRF-38535 and herein for device classes Q and V or MIL-PRF-38535, appendix A and herein for device class M.
3.2.1 Case outlines. The case outlines shall be in accordance with 1.2.4 herein and figure .
3.2.2 Terminal connections. The terminal connections shall be as specified on figure 1.
3.2.3 Radiation exposure circuit. The radiation exposure circuit shall be maintained by the manufacturer under document
revision level control and shall be made available to the preparing and acquiring activity upon request.
3.3 Electrical performance characteristics and postirradiation parameter limits. Unless otherwise specified herein, the
electrical performance characteristics and postirradiation parameter limits are as specified in table IA and shall apply over the
full ambient operating temperature range.
3.4 Electrical test requirements. The electrical test requirements shall be the subgroups specified in table IIA. The electrical
tests for each subgroup are defined in table IA.
3.5 Marking. The part shall be marked with the PIN listed in 1.2 herein. In addition, the manufacturer's PIN may also be
marked. For packages where marking of the entire SMD PIN number is not feasible due to space limitations, the manufacturer
has the option of not marking the "5962-" on the device. For RHA product using this option, the RHA designator shall still be
marked. Marking for device classes Q and V shall be in accordance with MIL-PRF-38535. Marking for device class M shall be
in accordance with MIL-PRF-38535, appendix A.
3.5.1 Certification/compliance mark. The certification mark for device classes Q and V shall be a "QML" or "Q" as required in
MIL-PRF-38535. The compliance mark for device class M shall be a "C" as required in MIL-PRF-38535, appendix A.
3.6 Certificate of compliance. For device classes Q and V, a certificate of compliance shall be required from a QML-38535
listed manufacturer in order to supply to the requirements of this drawing (see 6.6.1 herein). For device class M, a certificate of
compliance shall be required from a manufacturer in order to be listed as an approved source of supply in MIL-HDBK-103 (see
6.6.2 herein). The certificate of compliance submitted to DLA Land and Maritime-VA prior to listing as an approved source of
supply for this drawing shall affirm that the manufacturer's product meets, for device classes Q and V, the requirements of
MIL-PRF-38535 and herein or for device class M, the requirements of MIL-PRF-38535, appendix A and herein.
3.7 Certificate of conformance. A certificate of conformance as required for device classes Q and V in MIL-PRF-38535 or for
device class M in MIL-PRF-38535, appendix A shall be provided with each lot of microcircuits delivered to this drawing.
3.8 Notification of change for device class M. For device class M, notification to DLA Land and Maritime-VA of change of
product (see 6.2 herein) involving devices acquired to this drawing is required for any change that affects this drawing.
3.9 Verification and review for device class M. For device class M, DLA Land and Maritime, DLA Land and Maritime 's agent,
and the acquiring activity retain the option to review the manufacturer's facility and applicable required documentation. Offshore
documentation shall be made available onshore at the option of the reviewer.
3.10 Microcircuit group assignment for device class M. Device class M devices covered by this drawing shall be in
microcircuit group number 59 (see MIL-PRF-38535, appendix A).
STANDARD
MICROCIRCUIT DRAWING
DLA LAND AND MARITIME
COLUMBUS, OHIO 43218-3990
DSCC FORM 2234
APR 97
SIZE
5962-87594
A
REVISION LEVEL
G
SHEET
5
TABLE IA. Electrical performance characteristics.
Test
Reverse breakdown
voltage
Symbol
Conditions 1/ 2/
-55°C ≤ TA ≤ +125°C
unless otherwise specified
VREF
IR = 10 µA
Group A
subgroups
Device
type
1
01,03,
05,61
2,3
10 µA ≤ IR ≤ 20 µA
1
IR = 20 µA
02,04,
06
2,3
20 µA ≤ IR ≤ 30 µA
1
IR = 1 mA
01,03,
05,61
2,3
1
02,04,
06
2,3
1
IR = 20 mA
01,03,
05,61
2,3
1
02,04,
06
2,3
Reverse breakdown
voltage change with
current
∆VREF /
10 µA ≤ IR ≤ 1 mA
1
∆IR
20 µA ≤ IR ≤ 1 mA
2,3
20 µA ≤ IR ≤ 1 mA
1
30 µA ≤ IR ≤ 1 mA
2,3
1 mA ≤ IR ≤ 20 mA
1
Limits
Min
1.223
Max
1.247
1.205
1.26
2.462
2.538
2.425
2.575
1.223
1.247
1.205
1.26
2.462
2.538
2.425
2.575
1.223
1.247
1.205
1.26
2.462
2.538
2.425
2.575
-1
1
-1.5
1.5
-1
1
-1.5
1.5
-10
10
-20
20
-1
-0.4
01,03,
05,61
02,04,
06
All
2,3
Forward bias voltage
VF
1
IF = 2 mA, TA = +25°C
Unit
All
V
V
V
V
V
V
mV
mV
mV
V
See footnotes at end of table.
STANDARD
MICROCIRCUIT DRAWING
DLA LAND AND MARITIME
COLUMBUS, OHIO 43218-3990
DSCC FORM 2234
APR 97
SIZE
5962-87594
A
REVISION LEVEL
G
SHEET
6
TABLE IA. Electrical performance characteristics – Continued.
Test
Symbol
Conditions 1/ 2/
-55°C ≤ TA ≤ +125°C
unless otherwise specified
Group A
subgroups
Device
type
Limits
1,2,3
03, 04
Max
30
05, 06
50
Min
Temperature coefficient 3/
TC
Unit
ppm/°C
1/
Device type 61 supplied to this drawing are characterized and tested through all levels M, D, P, L, and R of irradiation.
Pre and Post irradiation values are identical unless otherwise specified in Table IB. When performing post irradiation
electrical measurements for any RHA level, TA = +25°C.
2/
Device type 61 has been tested and exhibit enhanced low dose rate sensitivity (ELDRS) effects. Radiation end point limits
for the noted parameters are guaranteed for the conditions specified in MIL-STD-883, method 1019, condition D and
paragraph 3.13.3.b with an overtest factor of 1.5X. For 100 krad, units are tested to 150 krad and still meet the radiation
end point limits.
3/
The average temperature coefficient is defined as the maximum deviation of reference voltage at all measured
temperatures between the operating TMAX and TMIN divided by TMAX – TMIN. The measured temperatures are
-55°C, -40°C, 0°C, +25°C, +70°C, +85°C, and +125°C.
TABLE IB. Post irradiation (low dose rate) reference voltage drift limits.
Test
Symbol
Conditions
RHA level
designators
Group A
subgroups
IR = 10 µA
R
1
IR = 1 mA
Device type 61
Reverse breakdown
voltage tolerance
VREF
Min
Max
-3%
+3%
R
-3%
+3%
IR = 15 mA
R
-2.5%
+2.5%
-15 mV
15 mV
-25 mV
25 mV
-1 V
-0.4 V
Reverse breakdown
voltage change with
current
∆VREF/
10 µA < IR < 1 mA
R
∆IR
1 mA < IR < 20 mA
R
Forward bias voltage
VF
IF = 2 mA
R
STANDARD
MICROCIRCUIT DRAWING
DLA LAND AND MARITIME
COLUMBUS, OHIO 43218-3990
DSCC FORM 2234
APR 97
Post radiation at
25°C drift limit
1
1
SIZE
5962-87594
A
REVISION LEVEL
G
SHEET
7
Case X
Symbol
Inches
Millimeters
Min
Max
Min
Max
A
.080
.105
2.03
2.67
φb
.016
.019
0.41
0.48
φD
.209
.219
5.31
5.56
φD1
.178
.195
4.52
4.95
φe
---
.100
---
2.54
e1
---
.050
---
1.27
F
---
.030
---
0.76
k
.036
.046
0.91
1.17
k1
.028
.048
0.71
1.22
L
.500
---
12.70
---
Q
---
.025
---
0.64
α
45° BSC
45° BSC
NOTES:
1. Dimensions are in inches.
2. Metric equivalents are given for general information only.
3. The U.S. government preferred system of measurement is the metric SI system. However, since this item was
originally designed using inch-pound units of measurement, in the event of conflict between the metric and
inch-pound units, the inch-pound units shall take precedence.
FIGURE 1. Case outline.
STANDARD
MICROCIRCUIT DRAWING
DLA LAND AND MARITIME
COLUMBUS, OHIO 43218-3990
DSCC FORM 2234
APR 97
SIZE
5962-87594
A
REVISION LEVEL
G
SHEET
8
Device types
All
Case outlines
X
Terminal number
Y
2
Terminal symbol
1
VREF
NC
GND
2
GND
NC
NC
3
---
NC
NC
4
---
NC
NC
5
---
V-
NC
6
---
NC
NC
7
---
NC
NC
8
---
NC
NC
9
---
NC
NC
10
---
V+
NC
11
---
---
VREF+
12
---
---
NC
13
---
---
NC
14
---
---
NC
15
---
---
NC
16
---
---
NC
17
---
---
NC
18
---
---
NC
19
---
---
NC
20
---
---
NC
NC = No connection
FIGURE 2. Terminal connections.
STANDARD
MICROCIRCUIT DRAWING
DLA LAND AND MARITIME
COLUMBUS, OHIO 43218-3990
DSCC FORM 2234
APR 97
SIZE
5962-87594
A
REVISION LEVEL
G
SHEET
9
4. VERIFICATION
4.1 Sampling and inspection. For device classes Q and V, sampling and inspection procedures shall be in accordance with
MIL-PRF-38535 or as modified in the device manufacturer's Quality Management (QM) plan. The modification in the QM plan
shall not affect the form, fit, or function as described herein. For device class M, sampling and inspection procedures shall be in
accordance with MIL-PRF-38535, appendix A.
4.2 Screening. For device classes Q and V, screening shall be in accordance with MIL-PRF-38535, and shall be conducted
on all devices prior to qualification and technology conformance inspection. For device class M, screening shall be in
accordance with method 5004 of MIL-STD-883, and shall be conducted on all devices prior to quality conformance inspection.
4.2.1 Additional criteria for device class M.
a.
Burn-in test, method 1015 of MIL-STD-883.
(1) Test condition A, B, C, or D. The test circuit shall be maintained by the manufacturer under document revision
level control and shall be made available to the preparing or acquiring activity upon request. The test circuit shall
specify the inputs, outputs, biases, and power dissipation, as applicable, in accordance with the intent specified in
method 1015.
(2) TA = +125°C, minimum.
b.
Interim and final electrical test parameters shall be as specified in table IIA herein.
4.2.2 Additional criteria for device classes Q and V.
a.
The burn-in test duration, test condition and test temperature, or approved alternatives shall be as specified in the
device manufacturer's QM plan in accordance with MIL-PRF-38535. The burn-in test circuit shall be maintained under
document revision level control of the device manufacturer's Technology Review Board (TRB) in accordance with
MIL-PRF-38535 and shall be made available to the acquiring or preparing activity upon request. The test circuit shall
specify the inputs, outputs, biases, and power dissipation, as applicable, in accordance with the intent specified in
method 1015 of MIL-STD-883.
b.
Interim and final electrical test parameters shall be as specified in table IIA herein.
c.
Additional screening for device class V beyond the requirements of device class Q shall be as specified in
MIL-PRF-38535, appendix B.
4.3 Qualification inspection for device classes Q and V. Qualification inspection for device classes Q and V shall be in
accordance with MIL-PRF-38535. Inspections to be performed shall be those specified in MIL-PRF-38535 and herein for groups
A, B, C, D, and E inspections (see 4.4.1 through 4.4.4).
4.4 Conformance inspection. Technology conformance inspection for classes Q and V shall be in accordance with
MIL-PRF-38535 including groups A, B, C, D, and E inspections and as specified. Quality conformance inspection for device
class M shall be in accordance with MIL-PRF-38535, appendix A and as specified herein. Inspections to be performed for
device class M shall be those specified in method 5005 of MIL-STD-883 and herein for groups A, B, C, D, and E inspections
(see 4.4.1 through 4.4.4).
4.4.1 Group A inspection.
a.
Tests shall be as specified in table IIA herein.
b.
Subgroups 4, 5, 6, 7, 8, 9, 10, and 11 in table I, method 5005 of MIL-STD-883 shall be omitted.
STANDARD
MICROCIRCUIT DRAWING
DLA LAND AND MARITIME
COLUMBUS, OHIO 43218-3990
DSCC FORM 2234
APR 97
SIZE
5962-87594
A
REVISION LEVEL
G
SHEET
10
TABLE IIA. Electrical test requirements.
Test requirements
Subgroups
(in accordance with
MIL-STD-883,
method 5005, table I)
Device
class M
----
Interim electrical
parameters (see 4.2)
Final electrical
parameters (see 4.2)
Group A test
requirements (see 4.4)
Group C end-point electrical
parameters (see 4.4)
Group D end-point electrical
parameters (see 4.4)
Group E end-point electrical
parameters (see 4.4)
Subgroups
(in accordance with
MIL-PRF-38535, table III)
Device
class Q
----
Device
class V
----
1,2,3 1/
1,2,3 1/
1,2,3 1/
1,2,3
1,2,3
1,2,3
1,2,3
1,2,3
1,2,3 2/
1,2,3
1,2,3
1,2,3
---
---
1
1/ PDA applies to subgroup 1.
2/ Delta limits as specified in table IIB shall be required where specified, and delta limits
shall be computed with reference to the previous end point electrical parameters.`
TABLE IIB. Delta limits at +25°C.
Test
Reverse breakdown
voltage
Symbol
VREF
Conditions
Group A
subgroup
1
IR = 10 µA
Device
type
01, 61
IR = 20 mA
02
IR = 20 µA
IR = 20 mA
STANDARD
MICROCIRCUIT DRAWING
DLA LAND AND MARITIME
COLUMBUS, OHIO 43218-3990
DSCC FORM 2234
APR 97
Limits
Unit
Min
Max
-0.01
0.01
-0.01
0.01
-10
10
-10
10
V
mV
SIZE
5962-87594
A
REVISION LEVEL
G
SHEET
11
4.4.2 Group C inspection. The group C inspection end-point electrical parameters shall be as specified in table IIA herein.
4.4.2.1 Additional criteria for device class M. Steady-state life test conditions, method 1005 of MIL-STD-883:
a.
Test condition A, B, C, or D. The test circuit shall be maintained by the manufacturer under document revision level
control and shall be made available to the preparing or acquiring activity upon request. The test circuit shall specify the
inputs, outputs, biases, and power dissipation, as applicable, in accordance with the intent specified in method 1005 of
MIL-STD-883.
b.
TA = +125°C, minimum.
c.
Test duration: 1,000 hours, except as permitted by method 1005 of MIL-STD-883.
4.4.2.2 Additional criteria for device classes Q and V. The steady-state life test duration, test condition and test temperature,
or approved alternatives shall be as specified in the device manufacturer's QM plan in accordance with MIL-PRF-38535. The
test circuit shall be maintained under document revision level control by the device manufacturer's TRB in accordance with
MIL-PRF-38535 and shall be made available to the acquiring or preparing activity upon request. The test circuit shall specify the
inputs, outputs, biases, and power dissipation, as applicable, in accordance with the intent specified in method 1005 of
MIL-STD-883.
4.4.3 Group D inspection. The group D inspection end-point electrical parameters shall be as specified in table IIA herein.
4.4.4 Group E inspection. Group E inspection is required only for parts intended to be marked as radiation hardness assured
(see 3.5 herein).
a.
End-point electrical parameters shall be as specified in table IIA herein.
b.
For device classes Q and V, the devices or test vehicle shall be subjected to radiation hardness assured tests as
specified in MIL-PRF-38535 for the RHA level being tested. For device class M, the devices shall be subjected to
radiation hardness assured tests as specified in MIL-PRF-38535, appendix A for the RHA level being tested. All device
classes must meet the postirradiation end-point electrical parameter limits as defined in table IA at
TA = +25°C ±5°C, after exposure, to the subgroups specified in table IIA herein.
4.4.4.1 Total dose irradiation testing. Total dose irradiation testing shall be performed in accordance with MIL-STD-883
method 1019, condition D for device type 61 and as specified herein.
4.4.4.1.1 Accelerated annealing test. Accelerated annealing tests shall be performed on all devices requiring a RHA level
greater than 5 krads (Si). The post-anneal end-point electrical parameter limits shall be as specified in table IA herein and shall
be the pre-irradiation end-point electrical parameter limit at 25°C ±5°C. Testing shall be performed at initial qualification and
after any design or process changes which may affect the RHA response of the device.
5. PACKAGING
5.1 Packaging requirements. The requirements for packaging shall be in accordance with MIL-PRF-38535 for device classes
Q and V or MIL-PRF-38535, appendix A for device class M.
6. NOTES
6.1 Intended use. Microcircuits conforming to this drawing are intended for use for Government microcircuit applications
(original equipment), design applications, and logistics purposes.
6.1.1 Replaceability. Microcircuits covered by this drawing will replace the same generic device covered by a contractorprepared specification or drawing.
6.2 Configuration control of SMD's. All proposed changes to existing SMD's will be coordinated with the users of record for
the individual documents. This coordination will be accomplished using DD Form 1692, Engineering Change Proposal.
STANDARD
MICROCIRCUIT DRAWING
DLA LAND AND MARITIME
COLUMBUS, OHIO 43218-3990
DSCC FORM 2234
APR 97
SIZE
5962-87594
A
REVISION LEVEL
G
SHEET
12
6.3 Record of users. Military and industrial users should inform DLA Land and Maritime when a system application requires
configuration control and which SMD's are applicable to that system. DLA Land and Maritime will maintain a record of users and
this list will be used for coordination and distribution of changes to the drawings. Users of drawings covering microelectronic
devices (FSC 5962) should contact DLA Land and Maritime-VA, telephone (614) 692-8108.
6.4 Comments. Comments on this drawing should be directed to DLA Land and Maritime-VA, Columbus, Ohio 43218-3990,
or telephone (614) 692-0540.
6.5 Abbreviations, symbols, and definitions. The abbreviations, symbols, and definitions used herein are defined in
MIL-PRF-38535 and MIL-HDBK-1331.
6.6 Sources of supply.
6.6.1 Sources of supply for device classes Q and V. Sources of supply for device classes Q and V are listed in
MIL-HDBK-103 and QML-38535. The vendors listed in QML-38535 have submitted a certificate of compliance (see 3.6 herein)
to DLA Land and Maritime-VA and have agreed to this drawing.
6.6.2 Approved sources of supply for device class M. Approved sources of supply for class M are listed in MIL-HDBK-103.
The vendors listed in MIL-HDBK-103 have agreed to this drawing and a certificate of compliance (see 3.6 herein) has been
submitted to and accepted by DLA Land and Maritime-VA.
STANDARD
MICROCIRCUIT DRAWING
DLA LAND AND MARITIME
COLUMBUS, OHIO 43218-3990
DSCC FORM 2234
APR 97
SIZE
5962-87594
A
REVISION LEVEL
G
SHEET
13
STANDARD MICROCIRCUIT DRAWING BULLETIN
DATE: 14-02-04
Approved sources of supply for SMD 5962-87594 are listed below for immediate acquisition information only and
shall be added to MIL-HDBK-103 and QML-38535 during the next revision. MIL-HDBK-103 and QML-38535 will be
revised to include the addition or deletion of sources. The vendors listed below have agreed to this drawing and a
certificate of compliance has been submitted to and accepted by DLA Land and Maritime-VA. This information
bulletin is superseded by the next dated revision of MIL-HDBK-103 and QML-38535. DLA Land and Maritime
maintains an online database of all current sources of supply at http://www.landandmaritime.dla.mil/Programs/Smcr/.
Standard
microcircuit drawing
PIN 1/
Vendor
CAGE
number
Vendor
similar
PIN 2/
5962-8759401XA
27014
LM185H-1.2/883
3/
LM185H-1.2/883
5962-8759401YA
27014
LM185WG-1.2/883
5962-87594012A
3/
LM185E1.2/883
5962-8759402XA
27014
LM185H-2.5/883
3/
LM185H-2.5/883
5962-8759402YA
27014
LM185WG-2.5/883
5962-87594022A
3/
LM185E2.5883
5962-8759403XA
3/
LM185BXH1.2/883
5962-8759404XA
3/
LM185BXH2.5/883
5962-8759405XA
27014
LM185BYH1.2/883
5962-8759406XA
3/
LM185BYH2.5/883
5962-8759401VXA
27014
LM185H-1.2-QV
5962-8759401VYA
27014
LM185WG-1.2-QV
5962-8759402VYA
3/
LM185WG-2.5-QV
5962-8759406VXA
27014
LM185BYH2.5-QV
5962R8759461VXA
27014
LM185H-1.2RLQV
5962R8759461VYA
27014
LM185WG-1.2RLQV
1/ The lead finish shown for each PIN representing
a hermetic package is the most readily available
from the manufacturer listed for that part. If the
desired lead finish is not listed contact the vendor
to determine its availability.
2/ Caution. Do not use this number for item
acquisition. Items acquired to this number may not
satisfy the performance requirements of this drawing.
3/ Not available from an approved source of supply.
Vendor CAGE
number
27014
Vendor name
and address
National Semiconductor
2900 Semiconductor Dr.
P.O. Box 58090
Santa Clara, CA 95052-8090
The information contained herein is disseminated for convenience only and the
Government assumes no liability whatsoever for any inaccuracies in the
information bulletin.