PE38 Medium Loading

SAG AND TENSION TABLES FOR MEDIUM ICE LOADING
PE-38 0.4" DIAMETER FIGURE 8 CABLE
SAG UNDER
EXPECTED TENSION
STRINGING SAG MEDIUM LOADING
UNDER LOAD
SPAN LENGTH
STRINGING
(Feet)
TENSION(Lbs.) (Feet) - (Inches) (Feet) - (Inches)
(Lbs.)
50
200
0
4
0
10
352
75
200
0
9
1
7
408
100
200
1
5
2
5
457
125
200
2
2
3
6
498
150
200
3
1
4
9
534
175
200
4
3
6
1
565
200
200
5
6
7
7
591
225
200
7
0
9
3
615
250
200
8
7
11
1
635
275
250
8
4
11
7
732
300
250
9
11
13
5
754
325
250
11
7
15
4
773
350
300
11
3
15
11
866
375
300
12
11
17
10
886
400
350
12
7
18
5
973
425
400
12
5
19
3
1052
450
400
13
11
21
1
1075
475
400
15
6
23
1
1098
500
450
15
3
23
10
1175
UNLOADED SAG
AFTER STORM
(Feet) - (Inches)
0
5
0
10
1
6
2
3
3
3
4
4
5
8
7
1
8
9
8
6
10
1
11
10
11
6
13
2
12
11
12
11
14
5
16
0
15
10
NOTES: Medium ice loading is defined under NESC Rules 250 and 251 as 0.25 inch radial thickness of ice
and 4 PSF horizontal wind pressure at 15º Fahrenheit. Stringing tensions are at 60º (F).
03/23/04
Page 1
of 11
SAG AND TENSION TABLES FOR MEDIUM ICE LOADING
PE-38 0.5" DIAMETER FIGURE 8 CABLE
SAG UNDER
EXPECTED TENSION UNLOADED SAG
SPAN LENGTH
STRINGING
STRINGING SAG MEDIUM LOADING
UNDER LOAD
AFTER STORM
(Feet)
TENSION(Lbs.) (Feet) - (Inches) (Feet) - (Inches)
(Lbs.)
(Feet) - (Inches)
50
200
0
5
0
10
359
0
6
75
200
0
11
1
8
415
1
0
100
200
1
8
2
8
461
1
9
125
200
2
8
3
10
499
2
9
150
200
3
10
5
2
531
3
11
175
200
5
2
6
9
557
5
3
200
200
6
9
8
6
579
6
10
225
200
8
7
10
5
597
8
8
250
250
8
5
11
0
698
8
7
275
250
10
3
12
11
718
10
4
300
300
10
2
13
7
811
10
4
325
300
11
11
15
7
832
12
1
350
350
11
10
16
4
921
12
1
375
350
13
7
18
4
942
13
10
400
400
13
6
19
2
1026
13
11
425
500
12
2
19
2
1157
12
9
450
500
13
8
21
0
1183
14
2
475
500
15
3
22
11
1207
15
9
500
600
14
1
23
1
1327
14
9
NOTES: Medium ice loading is defined under NESC Rules 250 and 251 as 0.25 inch radial thickness of ice
and 4 PSF horizontal wind pressure at 15º Fahrenheit. Stringing tensions are at 60º (F).
03/23/04
Page 2
of 11
SAG AND TENSION TABLES FOR MEDIUM ICE LOADING
PE-38 0.6" DIAMETER FIGURE 8 CABLE
SAG UNDER
EXPECTED TENSION UNLOADED SAG
SPAN LENGTH
STRINGING
STRINGING SAG MEDIUM LOADING
UNDER LOAD
AFTER STORM
(Feet)
TENSION(Lbs.) (Feet) - (Inches) (Feet) - (Inches)
(Lbs.)
(Feet) - (Inches)
50
200
0
6
0
11
366
0
6
75
200
1
1
1
9
421
1
2
100
200
1
11
2
10
466
2
0
125
200
3
0
4
2
501
3
1
150
200
4
4
5
7
530
4
5
175
200
5
11
7
4
553
6
0
200
200
7
9
9
3
572
7
10
225
250
7
10
10
0
673
8
0
250
250
9
8
11
11
692
9
10
275
300
9
9
12
9
788
9
11
300
300
11
8
14
9
808
11
10
325
350
11
8
15
7
899
11
11
350
400
11
10
16
6
984
12
2
375
450
12
1
17
6
1066
12
6
400
500
12
5
18
6
1144
12
10
425
500
14
0
20
5
1169
14
6
450
550
14
3
21
6
1245
14
10
475
600
14
7
22
8
1319
15
2
500
600
16
2
24
7
1344
16
9
NOTES: Medium ice loading is defined under NESC Rules 250 and 251 as 0.25 inch radial thickness of ice
and 4 PSF horizontal wind pressure at 15º Fahrenheit. Stringing tensions are at 60º (F).
03/23/04
Page 3
of 11
SAG AND TENSION TABLES FOR MEDIUM ICE LOADING
PE-38 0.7" DIAMETER FIGURE 8 CABLE
SAG UNDER
EXPECTED TENSION
SPAN LENGTH
STRINGING
STRINGING SAG MEDIUM LOADING
UNDER LOAD
(Feet)
TENSION(Lbs.) (Feet) - (Inches) (Feet) - (Inches)
(Lbs.)
50
200
0
8
1
0
369
75
200
1
5
2
0
420
100
200
2
6
3
3
457
125
200
3
11
4
9
484
150
200
5
8
6
7
504
175
250
6
2
7
6
602
200
300
6
8
8
6
694
225
300
8
5
10
5
716
250
350
8
11
11
5
806
275
400
9
5
12
6
892
300
400
11
3
14
6
914
325
500
10
7
14
9
1054
350
500
12
3
16
9
1079
375
550
12
9
17
11
1158
400
600
13
4
19
1
1235
425
650
13
11
20
4
1310
450
700
14
6
21
7
1384
475
800
14
1
22
2
1500
500
800
15
8
24
1
1528
UNLOADED SAG
AFTER STORM
(Feet) - (Inches)
0
8
1
5
2
7
4
0
5
8
6
3
6
10
8
7
9
1
9
8
11
6
10
11
12
7
13
2
13
9
14
5
15
1
14
10
16
4
NOTES: Medium ice loading is defined under NESC Rules 250 and 251 as 0.25 inch radial thickness of ice
and 4 PSF horizontal wind pressure at 15º Fahrenheit. Stringing tensions are at 60º (F).
03/23/04
Page 4
of 11
SAG AND TENSION TABLES FOR MEDIUM ICE LOADING
PE-38 0.8" DIAMETER FIGURE 8 CABLE
SAG UNDER
EXPECTED TENSION UNLOADED SAG
SPAN LENGTH
STRINGING
STRINGING SAG MEDIUM LOADING
UNDER LOAD
AFTER STORM
(Feet)
TENSION(Lbs.) (Feet) - (Inches) (Feet) - (Inches)
(Lbs.)
(Feet) - (Inches)
50
200
0
9
1
1
372
0
9
75
200
1
8
2
2
417
1
9
100
200
3
0
3
7
448
3
1
125
200
4
8
5
4
469
4
9
150
250
5
5
6
5
566
5
6
175
250
7
4
8
5
584
7
5
200
300
8
0
9
6
679
8
1
225
350
8
8
10
7
769
8
10
250
400
9
5
11
9
856
9
7
275
450
10
1
13
0
940
10
4
300
500
10
10
14
2
1022
11
1
325
550
11
6
15
5
1102
11
10
350
600
12
3
16
9
1181
12
7
375
650
13
0
18
0
1258
13
5
400
700
13
9
19
4
1334
14
2
425
800
13
7
20
0
1455
14
2
450
800
15
2
22
0
1482
15
10
475
900
15
0
22
9
1599
15
9
500
1000
15
0
23
6
1713
15
10
NOTES: Medium ice loading is defined under NESC Rules 250 and 251 as 0.25 inch radial thickness of ice
and 4 PSF horizontal wind pressure at 15º Fahrenheit. Stringing tensions are at 60º (F).
03/23/04
Page 5
of 11
SAG AND TENSION TABLES FOR MEDIUM ICE LOADING
PE-38 0.9" DIAMETER FIGURE 8 CABLE
SAG UNDER
EXPECTED TENSION UNLOADED SAG
SPAN LENGTH
STRINGING
STRINGING SAG MEDIUM LOADING
UNDER LOAD
AFTER STORM
(Feet)
TENSION(Lbs.) (Feet) - (Inches) (Feet) - (Inches)
(Lbs.)
(Feet) - (Inches)
50
200
0
11
1
2
372
0
11
75
200
2
0
2
5
412
2
0
100
200
3
6
4
0
438
3
6
125
250
4
5
5
2
533
4
5
150
250
6
4
7
2
552
6
4
175
300
7
2
8
4
645
7
3
200
350
8
0
9
6
736
8
1
225
400
8
10
10
9
823
9
0
250
450
9
9
12
1
908
9
11
275
500
10
7
13
4
992
10
10
300
550
11
5
14
8
1073
11
9
325
600
12
4
16
1
1153
12
8
350
700
12
3
16
9
1283
12
8
400
800
14
0
19
7
1435
14
6
450
1000
14
2
21
3
1672
14
11
500
1100
15
11
24
2
1815
16
9
NOTES: Medium ice loading is defined under NESC Rules 250 and 251 as 0.25 inch radial thickness of ice
and 4 PSF horizontal wind pressure at 15º Fahrenheit. Stringing tensions are at 60º (F).
03/23/04
Page 6
of 11
SAG AND TENSION TABLES FOR MEDIUM ICE LOADING
PE-38 1.0" DIAMETER FIGURE 8 CABLE
SAG UNDER
EXPECTED TENSION UNLOADED SAG
SPAN LENGTH
STRINGING
STRINGING SAG MEDIUM LOADING
UNDER LOAD
AFTER STORM
(Feet)
TENSION(Lbs.) (Feet) - (Inches) (Feet) - (Inches)
(Lbs.)
(Feet) - (Inches)
50
200
1
0
1
3
373
1
0
75
200
2
3
2
7
409
2
3
100
200
3
11
4
5
430
4
0
125
250
4
11
5
7
526
5
0
150
300
5
11
6
10
618
6
0
175
350
6
11
8
2
708
7
0
200
400
7
11
9
6
796
8
0
225
500
8
0
10
2
940
8
2
250
500
9
10
12
2
965
10
0
275
600
9
11
12
11
1103
10
2
300
700
10
2
13
9
1233
10
6
325
700
11
11
15
9
1261
12
3
350
800
12
1
16
8
1388
12
6
375
900
12
4
17
7
1510
12
10
400
1000
12
7
18
6
1628
13
3
425
1000
14
3
20
6
1659
14
10
450
1100
14
6
21
6
1775
15
3
NOTES: Medium ice loading is defined under NESC Rules 250 and 251 as 0.25 inch radial thickness of ice
and 4 PSF horizontal wind pressure at 15º Fahrenheit. Stringing tensions are at 60º (F).
03/23/04
Page 7
of 11
SAG AND TENSION TABLES FOR MEDIUM ICE LOADING
PE-38 1.1" DIAMETER FIGURE 8 CABLE
SAG UNDER
EXPECTED TENSION UNLOADED SAG
SPAN LENGTH
STRINGING
STRINGING SAG MEDIUM LOADING
UNDER LOAD
AFTER STORM
(Feet)
TENSION(Lbs.) (Feet) - (Inches) (Feet) - (Inches)
(Lbs.)
(Feet) - (Inches)
50
200
1
2
1
5
367
1
3
75
200
2
8
3
0
395
2
8
100
250
3
10
4
3
488
3
10
125
300
4
11
5
7
578
5
0
150
350
6
1
7
0
667
6
2
175
400
7
3
8
5
753
7
4
200
500
7
7
9
3
899
7
9
225
550
8
9
10
9
982
8
11
250
600
9
11
12
3
1064
10
1
275
700
10
3
13
2
1197
10
6
300
800
10
8
14
1
1326
11
0
325
900
11
2
15
2
1451
11
7
350
900
12
11
17
3
1480
13
4
375
1000
13
4
18
3
1603
13
11
400
1100
13
10
19
4
1723
14
5
425
1100
15
7
21
5
1753
16
3
SAG AND TENSION TABLES FOR MEDIUM ICE LOADING
PE-38 1.2" DIAMETER FIGURE 8 CABLE
SAG UNDER
EXPECTED TENSION UNLOADED SAG
SPAN LENGTH
STRINGING
STRINGING SAG MEDIUM LOADING
UNDER LOAD
AFTER STORM
(Feet)
TENSION(Lbs.) (Feet) - (Inches) (Feet) - (Inches)
(Lbs.)
(Feet) - (Inches)
50
200
1
5
1
7
359
1
5
75
200
3
2
3
5
379
3
3
100
300
3
10
4
3
540
3
10
125
400
4
5
5
3
689
4
6
150
400
6
5
7
3
713
6
6
175
500
7
0
8
3
859
7
1
200
600
7
7
9
3
997
7
9
225
650
8
10
10
10
1079
9
1
250
700
10
2
12
5
1159
10
5
275
800
10
9
13
6
1291
11
0
300
900
11
5
14
7
1419
11
9
325
1000
12
0
15
9
1544
12
5
350
1100
12
8
16
11
1667
13
2
NOTES: Medium ice loading is defined under NESC Rules 250 and 251 as 0.25 inch radial thickness of ice
and 4 PSF horizontal wind pressure at 15º Fahrenheit. Stringing tensions are at 60º (F).
03/23/04
Page 8
of 11
SAG AND TENSION TABLES FOR MEDIUM ICE LOADING
PE-38 1.3" DIAMETER FIGURE 8 CABLE
SAG UNDER
EXPECTED TENSION UNLOADED SAG
SPAN LENGTH
STRINGING
STRINGING SAG MEDIUM LOADING
UNDER LOAD
AFTER STORM
(Feet)
TENSION(Lbs.) (Feet) - (Inches) (Feet) - (Inches)
(Lbs.)
(Feet) - (Inches)
50
200
1
7
1
9
356
1
7
75
250
2
10
3
1
447
2
10
100
300
4
2
4
7
535
4
2
125
400
4
11
5
7
687
4
11
150
500
5
8
6
8
831
5
9
175
550
7
0
8
3
914
7
1
200
600
8
4
9
10
997
8
6
225
700
9
0
11
0
1133
9
3
250
800
9
9
12
2
1266
10
0
275
900
10
6
13
4
1395
10
10
300
1000
11
3
14
6
1522
11
8
325
1100
12
0
15
9
1647
12
5
350
1100
13
11
17
11
1677
14
5
SAG AND TENSION TABLES FOR MEDIUM ICE LOADING
PE-38 1.4" DIAMETER FIGURE 8 CABLE
SPAN LENGTH
STRINGING
STRINGING SAG
(Feet)
TENSION(Lbs.) (Feet) - (Inches)
50
200
1
11
75
250
3
5
100
350
4
3
125
500
4
8
150
600
5
8
175
600
7
8
200
750
8
0
225
850
8
11
250
950
9
10
275
1100
10
4
300
1100
12
3
SAG UNDER
EXPECTED TENSION UNLOADED SAG
MEDIUM LOADING
UNDER LOAD
AFTER STORM
(Feet) - (Inches)
(Lbs.)
(Feet) - (Inches)
2
0
343
1
11
3
7
429
3
5
4
8
583
4
4
5
5
789
4
9
6
8
928
5
9
8
9
954
7
9
9
7
1145
8
2
10
10
1277
9
2
12
2
1407
10
2
13
1
1582
10
8
15
3
1613
12
8
NOTES: Medium ice loading is defined under NESC Rules 250 and 251 as 0.25 inch radial thickness of ice
and 4 PSF horizontal wind pressure at 15º Fahrenheit. Stringing tensions are at 60º (F).
03/23/04
Page 9
of 11
SAG AND TENSION TABLES FOR MEDIUM ICE LOADING
PE-38 1.5" DIAMETER FIGURE 8 CABLE
SPAN LENGTH
STRINGING
STRINGING SAG
(Feet)
TENSION(Lbs.) (Feet) - (Inches)
50
200
2
0
75
300
3
1
100
400
4
1
125
500
5
1
150
600
6
1
175
700
7
1
200
800
8
2
225
900
9
2
250
1000
10
2
275
1100
11
2
SAG UNDER
EXPECTED TENSION UNLOADED SAG
MEDIUM LOADING
UNDER LOAD
AFTER STORM
(Feet) - (Inches)
(Lbs.)
(Feet) - (Inches)
2
2
339
2
1
3
4
495
3
1
4
6
643
4
1
5
9
788
5
2
7
1
928
6
2
8
4
1065
7
3
9
8
1199
8
4
11
1
1332
9
4
12
5
1462
10
5
13
10
1590
11
6
SAG AND TENSION TABLES FOR MEDIUM ICE LOADING
PE-38 1.6" DIAMETER FIGURE 8 CABLE
SPAN LENGTH
STRINGING
STRINGING SAG
(Feet)
TENSION(Lbs.) (Feet) - (Inches)
50
200
2
4
75
300
3
6
100
450
4
2
125
550
5
4
150
700
6
0
175
800
7
2
200
900
8
4
225
1000
9
6
250
1100
10
8
SAG UNDER
EXPECTED TENSION UNLOADED SAG
MEDIUM LOADING
UNDER LOAD
AFTER STORM
(Feet) - (Inches)
(Lbs.)
(Feet) - (Inches)
2
5
328
2
4
3
9
482
3
6
4
7
692
4
3
6
0
834
5
5
7
0
1027
6
2
8
5
1162
7
4
9
10
1295
8
6
11
4
1427
9
9
12
10
1556
10
11
NOTES: Medium ice loading is defined under NESC Rules 250 and 251 as 0.25 inch radial thickness of ice
and 4 PSF horizontal wind pressure at 15º Fahrenheit. Stringing tensions are at 60º (F).
03/23/04
Page 10
of 11
SAG AND TENSION TABLES FOR MEDIUM ICE LOADING
PE-38 1.7" DIAMETER FIGURE 8 CABLE
SPAN LENGTH
STRINGING
STRINGING SAG
(Feet)
TENSION(Lbs.) (Feet) - (Inches)
50
250
2
1
75
350
3
4
100
500
4
2
125
600
5
4
150
750
6
2
175
900
7
0
200
1000
8
3
225
1100
9
6
SAG UNDER
EXPECTED TENSION UNLOADED SAG
MEDIUM LOADING
UNDER LOAD
AFTER STORM
(Feet) - (Inches)
(Lbs.)
(Feet) - (Inches)
2
2
393
2
1
3
7
542
3
4
4
7
746
4
2
6
0
887
5
5
7
2
1078
6
4
8
3
1264
7
2
9
9
1397
8
6
11
4
1528
9
9
SAG AND TENSION TABLES FOR MEDIUM ICE LOADING
PE-38 1.8" DIAMETER FIGURE 8 CABLE
SPAN LENGTH
STRINGING
STRINGING SAG
(Feet)
TENSION(Lbs.) (Feet) - (Inches)
50
250
2
3
75
400
3
2
100
500
4
6
125
650
5
5
150
800
6
4
175
900
7
8
200
1100
8
2
SAG UNDER
EXPECTED TENSION UNLOADED SAG
MEDIUM LOADING
UNDER LOAD
AFTER STORM
(Feet) - (Inches)
(Lbs.)
(Feet) - (Inches)
2
4
388
2
3
3
5
599
3
2
4
11
742
4
7
6
1
939
5
6
7
3
1130
6
5
8
10
1265
7
10
9
9
1498
8
5
SAG AND TENSION TABLES FOR MEDIUM ICE LOADING
PE-38 1.9" DIAMETER FIGURE 8 CABLE
SPAN LENGTH
STRINGING
STRINGING SAG
(Feet)
TENSION(Lbs.) (Feet) - (Inches)
50
300
2
5
75
600
2
8
100
800
3
7
125
900
5
0
150
1000
6
6
175
1100
8
0
SAG UNDER
EXPECTED TENSION UNLOADED SAG
MEDIUM LOADING
UNDER LOAD
AFTER STORM
(Feet) - (Inches)
(Lbs.)
(Feet) - (Inches)
2
6
432
2
5
3
0
804
2
9
4
1
1045
3
8
5
8
1182
5
1
7
4
1316
6
7
9
1
1448
8
2
NOTES: Medium ice loading is defined under NESC Rules 250 and 251 as 0.25 inch radial thickness of ice
and 4 PSF horizontal wind pressure at 15º Fahrenheit. Stringing tensions are at 60º (F).
03/23/04
Page 11
of 11