SAG AND TENSION TABLES FOR MEDIUM LOADING AREAS
22 AWG DOUBLE JACKET FIGURE 8
BHAP-25
SAG UNDER
EXPECTED TENSION
SPAN LENGTH
STRINGING
STRINGING SAG MEDIUM LOADING UNDER MEDIUM LOAD
(Feet)
TENSION(Lbs.) (Feet) - (Inches) (Feet) - (Inches)
(Lbs.)
50
500
0
4
0
8
624
75
500
0
9
1
5
682
100
500
1
4
2
4
739
125
500
2
1
3
5
790
150
500
3
0
4
8
837
175
500
4
1
6
1
879
200
500
5
4
7
7
917
225
500
6
8
9
3
951
250
500
8
3
11
1
981
275
500
10
0
13
0
1009
300
600
9
11
13
8
1143
325
600
11
8
15
8
1171
350
700
11
7
16
5
1299
375
700
13
4
18
5
1327
400
800
13
3
19
2
1451
425
800
14
11
21
3
1479
450
900
14
11
22
0
1600
475
1000
14
11
22
10
1716
500
1000
16
7
24
11
1745
UNLOADED SAG
AFTER STORM
(Feet) - (Inches)
0
5
0
11
1
6
2
3
3
2
4
3
5
6
6
11
8
6
10
3
10
3
12
0
12
0
13
9
13
9
15
6
15
7
15
9
17
4
BHAP-50
SAG UNDER
EXPECTED TENSION
SPAN LENGTH
STRINGING
STRINGING SAG MEDIUM LOADING UNDER MEDIUM LOAD
(Feet)
TENSION(Lbs.) (Feet) - (Inches) (Feet) - (Inches)
(Lbs.)
50
500
0
5
0
9
636
75
500
1
0
1
7
698
100
500
1
9
2
8
754
125
500
2
8
3
11
803
150
500
3
11
5
4
846
175
500
5
3
6
11
883
200
500
6
11
8
9
915
225
500
8
9
10
9
942
250
600
9
0
11
7
1080
275
600
10
10
13
8
1107
300
700
11
1
14
6
1241
325
800
11
5
15
5
1369
350
900
11
9
16
5
1493
375
1000
12
2
17
5
1614
400
1000
13
10
19
6
1645
425
1100
14
2
20
6
1764
450
1100
15
11
22
7
1794
475
1200
16
3
23
8
1912
500
1300
16
7
24
8
2027
UNLOADED SAG
AFTER STORM
(Feet) - (Inches)
0
6
1
1
1
10
2
10
4
0
5
5
7
1
8
11
9
3
11
1
11
5
11
9
12
3
12
8
14
5
14
10
16
7
17
0
17
6
NOTES: Medium ice loading is defined under NESC Rules 250 and 251 as 0.25 inch radial thickness
of ice and 4 PSF horizontal wind pressure at 15º Fahrenheit. Stringing tensions are at 60º (F).
04/08/04
Page 1 of 12
SAG AND TENSION TABLES FOR MEDIUM LOADING AREAS
22 AWG DOUBLE JACKET FIGURE 8
BHAP-100
SAG UNDER
EXPECTED TENSION
SPAN LENGTH
STRINGING
STRINGING SAG MEDIUN LOADING UNDER MEDIUM LOAD
(Feet)
TENSION(Lbs.) (Feet) - (Inches) (Feet) - (Inches)
(Lbs.)
50
500
0
8
1
0
656
75
500
1
5
1
12
719
100
500
2
6
3
3
771
125
500
3
11
4
10
813
150
500
5
8
6
8
846
175
500
7
8
8
10
872
200
600
8
4
9
11
1015
225
700
9
0
11
1
1153
250
800
9
9
12
3
1287
275
900
10
6
13
5
1418
300
1000
11
3
14
8
1546
325
1100
12
0
15
11
1672
350
1200
12
9
17
2
1796
375
1300
13
6
18
6
1919
400
1400
14
3
19
9
2040
425
1500
15
1
21
1
2160
450
1600
15
10
22
5
2278
UNLOADED SAG
AFTER STORM
(Feet) - (Inches)
0
8
1
6
2
7
4
0
5
9
7
9
8
6
9
3
10
0
10
10
11
8
12
5
13
3
14
2
15
0
15
10
16
9
NOTES: Medium ice loading is defined under NESC Rules 250 and 251 as 0.25 inch radial thickness
of ice and 4 PSF horizontal wind pressure at 15º Fahrenheit. Stringing tensions are at 60º (F).
04/08/04
Page 2 of 12
SAG AND TENSION TABLES FOR MEDIUM LOADING AREAS
22 AWG SINGLE JACKET FIGURE 8
BHAS-25
SAG UNDER
EXPECTED TENSION
SPAN LENGTH
STRINGING
STRINGING SAG MEDIUM LOADING UNDER MEDIUM LOAD
(Feet)
TENSION(Lbs.) (Feet) - (Inches) (Feet) - (Inches)
(Lbs.)
50
500
0
3
0
7
607
75
500
0
6
1
2
658
100
500
0
10
2
0
710
125
500
1
4
2
11
762
150
500
1
11
3
11
810
175
500
2
7
5
1
856
200
500
3
5
6
3
899
225
500
4
4
7
7
939
250
500
5
4
9
0
977
275
500
6
5
10
6
1012
300
500
7
8
12
2
1046
325
500
9
0
13
10
1077
350
500
10
5
15
7
1106
375
500
11
11
17
6
1133
400
600
11
4
17
11
1258
425
600
12
10
19
10
1286
450
700
12
4
20
4
1403
475
700
13
8
22
3
1432
500
800
13
3
22
10
1545
UNLOADED SAG
AFTER STORM
(Feet) - (Inches)
0
4
0
8
1
1
1
7
2
2
2
11
3
9
4
8
5
8
6
9
8
0
9
4
10
10
12
4
11
11
13
4
13
0
14
5
14
2
BHAS-50
SAG UNDER
EXPECTED TENSION
SPAN LENGTH
STRINGING
STRINGING SAG MEDIUM LOADING UNDER MEDIUM LOAD
(Feet)
TENSION(Lbs.) (Feet) - (Inches) (Feet) - (Inches)
(Lbs.)
50
500
0
4
0
8
620
75
500
0
8
1
5
677
100
500
1
2
2
3
733
125
500
1
11
3
4
785
150
500
2
8
4
6
833
175
500
3
8
5
9
877
200
500
4
10
7
3
916
225
500
6
1
8
10
952
250
500
7
6
10
6
985
275
500
9
1
12
4
1015
300
500
10
10
14
4
1041
325
600
10
7
14
11
1174
350
600
12
3
16
11
1202
375
700
12
1
17
6
1329
400
700
13
9
19
6
1357
425
800
13
7
20
3
1479
450
800
15
2
22
3
1507
475
900
15
0
23
0
1625
500
900
16
8
25
0
1653
UNLOADED SAG
AFTER STORM
(Feet) - (Inches)
0
5
0
10
1
5
2
1
2
11
3
11
5
0
6
4
7
9
9
4
11
1
10
11
12
7
12
6
14
2
14
2
15
10
15
9
17
5
NOTES: Medium ice loading is defined under NESC Rules 250 and 251 as 0.25 inch radial thickness
of ice and 4 PSF horizontal wind pressure at 15º Fahrenheit. Stringing tensions are at 60º (F).
04/08/04
Page 3 of 12
SAG AND TENSION TABLES FOR MEDIUM LOADING AREAS
22 AWG SINGLE JACKET FIGURE 8
BHAS-100
SAG UNDER
EXPECTED TENSION
SPAN LENGTH
STRINGING
STRINGING SAG MEDIUM LOADING UNDER MEDIUM LOAD
(Feet)
TENSION(Lbs.) (Feet) - (Inches) (Feet) - (Inches)
(Lbs.)
50
500
0
6
0
10
642
75
500
1
1
1
8
705
100
500
1
11
2
9
762
125
500
2
11
4
1
811
150
500
4
3
5
7
853
175
500
5
9
7
4
888
200
500
7
6
9
3
918
225
600
7
11
10
2
1056
250
600
9
9
12
3
1085
275
700
10
2
13
2
1220
300
800
10
7
14
2
1349
325
800
12
5
16
3
1379
350
900
12
9
17
3
1506
375
1000
13
2
18
4
1630
400
1100
13
8
19
5
1750
425
1200
14
1
20
6
1869
450
1300
14
7
21
8
1986
475
1300
16
3
23
9
2018
500
1400
16
9
24
11
2134
UNLOADED SAG
AFTER STORM
(Feet) - (Inches)
0
7
1
2
2
0
3
1
4
4
5
11
7
8
8
1
10
0
10
5
10
11
12
9
13
2
13
9
14
3
14
10
15
5
17
2
17
9
NOTES: Medium ice loading is defined under NESC Rules 250 and 251 as 0.25 inch radial thickness
of ice and 4 PSF horizontal wind pressure at 15º Fahrenheit. Stringing tensions are at 60º (F).
04/08/04
Page 4 of 12
SAG AND TENSION TABLES FOR MEDIUM LOADING AREAS
24 AWG DOUBLE JACKET FIGURE 8
BKMP-25
SAG UNDER
EXPECTED TENSION
SPAN LENGTH
STRINGING
STRINGING SAG MEDIUM LOADING UNDER MEDIUM LOAD
(Feet)
TENSION(Lbs.) (Feet) - (Inches) (Feet) - (Inches)
(Lbs.)
50
500
0
3
0
8
619
75
500
0
8
1
4
676
100
500
1
2
2
3
732
125
500
1
9
3
3
785
150
500
2
6
4
5
835
175
500
3
5
5
8
880
200
500
4
6
7
1
921
225
500
5
8
8
7
958
250
500
7
0
10
3
993
275
500
8
6
12
0
1024
300
500
10
2
13
11
1053
325
600
9
11
14
6
1183
350
600
11
6
16
5
1213
375
700
11
4
17
1
1337
400
700
12
10
19
0
1367
425
800
12
8
19
9
1486
450
800
14
3
21
8
1516
475
900
14
1
22
5
1632
500
900
15
8
24
5
1662
UNLOADED SAG
AFTER STORM
(Feet) - (Inches)
0
5
0
10
1
4
2
0
2
9
3
8
4
9
5
11
7
4
8
9
10
5
10
3
11
11
11
10
13
5
13
4
14
11
14
11
16
5
BKMP-50
SAG UNDER
EXPECTED TENSION
SPAN LENGTH
STRINGING
STRINGING SAG MEDIUM LOADING UNDER MEDIUM LOAD
(Feet)
TENSION(Lbs.) (Feet) - (Inches) (Feet) - (Inches)
(Lbs.)
50
500
0
4
0
9
628
75
500
0
10
1
6
688
100
500
1
5
2
5
746
125
500
2
3
3
7
798
150
500
3
2
4
10
844
175
500
4
4
6
3
886
200
500
5
8
7
11
922
225
500
7
3
9
8
955
250
500
8
11
11
7
984
275
600
9
0
12
4
1118
300
600
10
8
14
3
1147
325
700
10
9
15
1
1277
350
700
12
6
17
1
1306
375
800
12
6
17
10
1431
400
800
14
3
19
11
1460
425
900
14
4
20
9
1582
450
1000
14
5
21
8
1700
475
1000
16
1
23
9
1729
500
1100
16
2
24
8
1845
UNLOADED SAG
AFTER STORM
(Feet) - (Inches)
0
6
0
11
1
7
2
5
3
5
4
7
5
11
7
5
9
1
9
3
11
0
11
2
12
10
13
0
14
9
14
11
15
2
16
10
17
1
NOTES: Medium ice loading is defined under NESC Rules 250 and 251 as 0.25 inch radial thickness
of ice and 4 PSF horizontal wind pressure at 15º Fahrenheit. Stringing tensions are at 60º (F).
04/08/04
Page 5 of 12
SAG AND TENSION TABLES FOR MEDIUM LOADING AREAS
24 AWG DOUBLE JACKET FIGURE 8
BKMP-100
SAG UNDER
EXPECTED TENSION
SPAN LENGTH
STRINGING
STRINGING SAG MEDIUM LOADING UNDER MEDIUM LOAD
(Feet)
TENSION(Lbs.) (Feet) - (Inches) (Feet) - (Inches)
(Lbs.)
50
500
0
6
0
10
642
75
500
1
1
1
9
705
100
500
1
11
2
10
761
125
500
3
1
4
2
809
150
500
4
5
5
9
849
175
500
6
0
7
6
883
200
500
7
10
9
6
911
225
600
8
3
10
5
1050
250
700
8
8
11
5
1183
275
700
10
6
13
5
1213
300
800
11
0
14
5
1343
325
900
11
5
15
6
1470
350
1000
11
11
16
7
1593
375
1100
12
6
17
8
1714
400
1100
14
2
19
9
1746
425
1200
14
8
20
11
1866
450
1300
15
2
22
0
1983
475
1400
15
9
23
2
2099
500
1500
16
3
24
4
2214
UNLOADED SAG
AFTER STORM
(Feet) - (Inches)
0
7
1
2
2
1
3
2
4
6
6
1
7
11
8
5
9
0
10
10
11
4
11
10
12
5
13
1
14
9
15
5
16
0
16
8
17
3
BKMP-200
SAG UNDER
EXPECTED TENSION
SPAN LENGTH
STRINGING
STRINGING SAG MEDIUM LOADING UNDER MEDIUM LOAD
(Feet)
TENSION(Lbs.) (Feet) - (Inches) (Feet) - (Inches)
(Lbs.)
50
500
0
9
1
1
660
75
500
1
8
2
2
720
100
500
2
11
3
7
767
125
500
4
7
5
4
803
150
500
6
7
7
6
829
175
600
7
6
8
8
972
200
700
8
4
9
11
1110
225
800
9
3
11
2
1245
250
900
10
2
12
6
1377
275
1000
11
1
13
10
1507
300
1100
12
0
15
2
1635
325
1200
12
10
16
6
1762
350
1400
12
10
17
1
1977
375
1500
13
9
18
6
2099
400
1600
14
8
19
10
2220
UNLOADED SAG
AFTER STORM
(Feet) - (Inches)
0
10
1
9
3
0
4
8
6
8
7
7
8
6
9
6
10
5
11
5
12
4
13
4
13
5
14
4
15
4
NOTES: Medium ice loading is defined under NESC Rules 250 and 251 as 0.25 inch radial thickness
of ice and 4 PSF horizontal wind pressure at 15º Fahrenheit. Stringing tensions are at 60º (F).
04/08/04
Page 6 of 12
SAG AND TENSION TABLES FOR MEDIUM LOADING AREAS
24 AWG SINGLE JACKET FIGURE 8
BKMS-25
SPAN LENGTH
(Feet)
50
75
100
125
150
175
200
225
250
275
300
325
350
375
400
425
450
475
500
SAG UNDER
EXPECTED TENSION
STRINGING
STRINGING SAG MEDIUM LOADING UNDER MEDIUM LOAD
TENSION(Lbs.) (Feet) - (Inches) (Feet) - (Inches)
(Lbs.)
500
0
2
0
7
602
500
0
5
1
2
650
500
0
9
1
11
701
500
1
2
2
9
751
500
1
8
3
9
799
500
2
3
4
9
845
500
2
11
5
11
888
500
3
8
7
2
929
500
4
6
8
6
969
500
5
6
9
11
1006
500
6
6
11
5
1041
500
7
8
13
0
1074
500
8
11
14
8
1105
500
10
2
16
4
1135
500
11
7
18
2
1163
500
13
1
20
0
1190
500
14
8
22
0
1216
600
13
8
22
3
1339
600
15
1
24
2
1366
UNLOADED SAG
AFTER STORM
(Feet) - (Inches)
0
4
0
8
1
0
1
5
1
11
2
7
3
3
4
1
4
11
5
11
7
0
8
1
9
4
10
8
12
1
13
7
15
2
14
4
15
10
BKMS-50
SPAN LENGTH
(Feet)
50
75
100
125
150
175
200
225
250
275
300
325
350
375
400
425
450
475
500
SAG UNDER
EXPECTED TENSION
STRINGING
STRINGING SAG MEDIUM LOADING UNDER MEDIUM LOAD
TENSION(Lbs.) (Feet) - (Inches) (Feet) - (Inches)
(Lbs.)
500
0
3
0
7
611
500
0
6
1
3
664
500
0
11
2
1
718
500
1
6
3
0
770
500
2
2
4
1
819
500
2
11
5
3
865
500
3
10
6
7
907
500
4
10
7
11
946
500
5
11
9
5
983
500
7
2
11
1
1017
500
8
7
12
9
1048
500
10
0
14
7
1078
500
11
8
16
6
1105
500
13
4
18
6
1131
600
12
8
18
10
1261
600
14
4
20
10
1288
700
13
9
21
4
1410
700
15
4
23
4
1438
800
14
10
23
11
1555
UNLOADED SAG
AFTER STORM
(Feet) - (Inches)
0
5
0
9
1
2
1
9
2
5
3
2
4
1
5
1
6
3
7
6
8
11
10
5
12
0
13
9
13
2
14
10
14
5
16
0
15
8
NOTES: Medium ice loading is defined under NESC Rules 250 and 251 as 0.25 inch radial thickness
of ice and 4 PSF horizontal wind pressure at 15º Fahrenheit. Stringing tensions are at 60º (F).
04/08/04
Page 7 of 12
SAG AND TENSION TABLES FOR MEDIUM LOADING AREAS
24 AWG SINGLE JACKET FIGURE 8
BKMS-100
SPAN LENGTH
(Feet)
50
75
100
125
150
175
200
225
250
275
300
325
350
375
400
425
450
475
500
SAG UNDER
EXPECTED TENSION
STRINGING
STRINGING SAG MEDIUM LOADING UNDER MEDIUM LOAD
TENSION(Lbs.) (Feet) - (Inches) (Feet) - (Inches)
(Lbs.)
500
0
4
0
9
626
500
0
9
1
6
686
500
1
5
2
5
743
500
2
2
3
6
794
500
3
2
4
10
841
500
4
3
6
3
882
500
5
7
7
10
919
500
7
1
9
6
952
500
8
9
11
5
981
500
10
7
13
5
1007
600
10
6
14
1
1143
700
10
7
14
10
1272
700
12
3
16
10
1301
800
12
4
17
8
1425
800
14
0
19
8
1454
900
14
1
20
6
1575
1000
14
2
21
5
1693
1000
15
10
23
6
1722
1100
15
11
24
4
1837
UNLOADED SAG
AFTER STORM
(Feet) - (Inches)
0
6
0
11
1
7
2
4
3
4
4
6
5
10
7
4
9
0
10
10
10
10
10
11
12
8
12
10
14
6
14
8
14
11
16
7
16
9
BKMS-200
SPAN LENGTH
(Feet)
50
75
100
125
150
175
200
225
250
275
300
325
350
375
400
425
450
475
500
SAG UNDER
EXPECTED TENSION
STRINGING
STRINGING SAG MEDIUM LOADING UNDER MEDIUM LOAD
TENSION(Lbs.) (Feet) - (Inches) (Feet) - (Inches)
(Lbs.)
500
0
7
0
11
644
500
1
3
1
10
705
500
2
2
3
0
757
500
3
5
4
5
800
500
4
11
6
1
835
500
6
9
8
0
864
600
7
4
9
1
1002
700
7
11
10
1
1136
700
9
10
12
2
1165
800
10
5
13
3
1296
900
11
0
14
4
1423
1000
11
7
15
6
1548
1100
12
3
16
8
1671
1100
14
1
18
9
1701
1200
14
8
19
11
1822
1300
15
3
21
1
1941
1400
15
11
22
4
2059
1500
16
7
23
6
2176
1600
17
2
24
9
2291
UNLOADED SAG
AFTER STORM
(Feet) - (Inches)
0
8
1
4
2
4
3
7
5
1
6
10
7
6
8
2
10
1
10
8
11
4
12
1
12
9
14
7
15
3
16
0
16
9
17
5
18
2
NOTES: Medium ice loading is defined under NESC Rules 250 and 251 as 0.25 inch radial thickness
of ice and 4 PSF horizontal wind pressure at 15º Fahrenheit. Stringing tensions are at 60º (F).
04/08/04
Page 8 of 12
SAG AND TENSION TABLES FOR MEDIUM LOADING AREAS
26 AWG DOUBLE JACKET FIGURE 8
BKTP-25
SPAN LENGTH
(Feet)
50
75
100
125
150
175
200
225
250
275
300
325
350
375
400
425
450
475
500
SAG UNDER
EXPECTED TENSION
STRINGING
STRINGING SAG MEDIUM LOADING UNDER MEDIUM LOAD
TENSION(Lbs.) (Feet) - (Inches) (Feet) - (Inches)
(Lbs.)
500
0
3
0
7
614
500
0
7
1
3
669
500
1
0
2
1
724
500
1
7
3
1
777
500
2
3
4
2
826
500
3
1
5
5
872
500
4
0
6
9
914
500
5
1
8
2
953
500
6
3
9
8
990
500
7
7
11
4
1023
500
9
0
13
1
1054
500
10
7
14
11
1083
500
12
3
16
11
1109
600
11
9
17
5
1240
600
13
4
19
4
1268
700
12
11
19
11
1391
700
14
6
21
11
1419
800
14
1
22
6
1537
800
15
8
24
6
1566
UNLOADED SAG
AFTER STORM
(Feet) - (Inches)
0
5
0
9
1
2
1
9
2
6
3
4
4
3
5
4
6
7
7
11
9
4
10
11
12
7
12
2
13
10
13
6
15
1
14
10
16
5
BKTP-50
SPAN LENGTH
(Feet)
50
75
100
125
150
175
200
225
250
275
300
325
350
375
400
425
450
475
500
SAG UNDER
EXPECTED TENSION
STRINGING
STRINGING SAG MEDIUM LOADING UNDER MEDIUM LOAD
TENSION(Lbs.) (Feet) - (Inches) (Feet) - (Inches)
(Lbs.)
500
0
4
0
8
621
500
0
8
1
5
679
500
1
2
2
3
736
500
1
11
3
4
789
500
2
8
4
6
837
500
3
8
5
10
882
500
4
10
7
3
922
500
6
1
8
10
958
500
7
6
10
7
991
500
9
1
12
5
1021
500
10
10
14
4
1049
600
10
7
14
11
1182
600
12
3
16
11
1210
700
12
1
17
7
1337
700
13
9
19
7
1366
800
13
7
20
4
1488
800
15
2
22
4
1516
900
15
0
23
1
1635
1000
15
0
23
11
1749
UNLOADED SAG
AFTER STORM
(Feet) - (Inches)
0
5
0
10
1
5
2
1
2
11
3
11
5
0
6
4
7
9
9
4
11
1
10
11
12
7
12
6
14
2
14
2
15
10
15
9
15
11
NOTES: Medium ice loading is defined under NESC Rules 250 and 251 as 0.25 inch radial thickness
of ice and 4 PSF horizontal wind pressure at 15º Fahrenheit. Stringing tensions are at 60º (F).
04/08/04
Page 9 of 12
SAG AND TENSION TABLES FOR MEDIUM LOADING AREAS
26 AWG DOUBLE JACKET FIGURE 8
BKTP-100
SPAN LENGTH
(Feet)
50
75
100
125
150
175
200
225
250
275
300
325
350
375
400
425
450
475
500
SAG UNDER
EXPECTED TENSION
STRINGING
STRINGING SAG MEDIUM LOADING UNDER MEDIUM LOAD
TENSION(Lbs.) (Feet) - (Inches) (Feet) - (Inches)
(Lbs.)
500
0
5
0
9
634
500
0
10
1
7
697
500
1
7
2
7
755
500
2
5
3
9
807
500
3
6
5
1
854
500
4
9
6
7
894
500
6
2
8
3
930
500
7
10
10
2
961
500
9
8
12
2
988
500
11
9
14
5
1012
600
11
8
15
0
1154
700
11
8
15
10
1288
800
11
10
16
8
1415
800
13
7
18
9
1444
900
13
9
19
8
1568
1000
14
0
20
7
1688
1100
14
3
21
7
1806
1100
15
11
23
8
1837
1200
16
2
24
8
1952
UNLOADED SAG
AFTER STORM
(Feet) - (Inches)
0
6
1
0
1
8
2
7
3
8
4
11
6
5
8
0
9
11
11
11
11
11
12
1
12
4
14
1
14
4
14
8
15
1
16
8
17
1
BKTP-200
SPAN LENGTH
(Feet)
50
75
100
125
150
175
200
225
250
275
300
325
350
375
400
425
450
475
500
SAG UNDER
EXPECTED TENSION
STRINGING
STRINGING SAG MEDIUM LOADING UNDER MEDIUM LOAD
TENSION(Lbs.) (Feet) - (Inches) (Feet) - (Inches)
(Lbs.)
500
0
7
0
11
649
500
1
3
1
10
712
500
2
2
3
0
767
500
3
5
4
6
811
500
4
11
6
2
848
500
6
9
8
1
878
600
7
4
9
1
1018
700
7
11
10
2
1153
700
9
10
12
3
1183
800
10
5
13
4
1315
900
11
0
14
6
1444
1000
11
7
15
7
1570
1100
12
3
16
10
1693
1200
12
11
18
0
1815
1300
13
6
19
2
1934
1400
14
2
20
5
2053
1400
15
11
22
7
2085
1500
16
7
23
9
2203
1600
17
2
25
0
2319
UNLOADED SAG
AFTER STORM
(Feet) - (Inches)
0
8
1
4
2
4
3
7
5
1
6
10
7
6
8
2
10
1
10
8
11
4
12
1
12
9
13
6
14
3
15
0
16
9
17
6
18
3
NOTES: Medium ice loading is defined under NESC Rules 250 and 251 as 0.25 inch radial thickness
of ice and 4 PSF horizontal wind pressure at 15º Fahrenheit. Stringing tensions are at 60º (F).
04/08/04
Page 10 of 12
SAG AND TENSION TABLES FOR MEDIUM LOADING AREAS
26 AWG SINGLE JACKET FIGURE 8
BKTS-25
SPAN LENGTH
(Feet)
50
75
100
125
150
175
200
225
250
275
300
325
350
375
400
425
450
475
500
SAG UNDER
EXPECTED TENSION
STRINGING
STRINGING SAG MEDIUM LOADING UNDER MEDIUM LOAD
TENSION(Lbs.) (Feet) - (Inches) (Feet) - (Inches)
(Lbs.)
500
0
2
0
6
598
500
0
4
1
1
643
500
0
8
1
10
692
500
1
0
2
8
740
500
1
6
3
7
787
500
2
0
4
7
832
500
2
7
5
9
875
500
3
3
6
11
916
500
4
1
8
2
956
500
4
11
9
6
993
500
5
10
10
11
1028
500
6
10
12
5
1062
500
8
0
14
0
1095
500
9
2
15
8
1125
500
10
5
17
4
1155
500
11
9
19
1
1183
500
13
2
20
11
1209
500
14
8
22
10
1235
500
16
3
24
10
1259
UNLOADED SAG
AFTER STORM
(Feet) - (Inches)
0
4
0
7
0
11
1
4
1
10
2
4
3
0
3
8
4
6
5
4
6
4
7
4
8
6
9
8
10
11
12
4
13
9
15
3
16
10
BKTS-50
SPAN LENGTH
(Feet)
50
75
100
125
150
175
200
225
250
275
300
325
350
375
400
425
450
475
500
SAG UNDER
EXPECTED TENSION
STRINGING
STRINGING SAG MEDIUM LOADING UNDER MEDIUM LOAD
TENSION(Lbs.) (Feet) - (Inches) (Feet) - (Inches)
(Lbs.)
500
0
2
0
7
604
500
0
5
1
2
653
500
0
9
1
11
705
500
1
3
2
10
755
500
1
9
3
10
804
500
2
4
4
11
850
500
3
1
6
1
893
500
3
11
7
4
934
500
4
10
8
9
973
500
5
10
10
2
1009
500
7
0
11
8
1044
500
8
2
13
4
1076
500
9
6
15
0
1107
500
10
11
16
10
1135
500
12
5
18
8
1163
600
11
8
19
1
1285
600
13
1
20
11
1313
600
14
7
22
10
1340
600
16
2
24
10
1366
UNLOADED SAG
AFTER STORM
(Feet) - (Inches)
0
4
0
8
1
0
1
6
2
1
2
8
3
5
4
3
5
3
6
3
7
5
8
7
9
11
11
4
12
10
12
3
13
8
15
2
16
10
NOTES: Medium ice loading is defined under NESC Rules 250 and 251 as 0.25 inch radial thickness
of ice and 4 PSF horizontal wind pressure at 15º Fahrenheit. Stringing tensions are at 60º (F).
04/08/04
Page 11 of 12
SAG AND TENSION TABLES FOR MEDIUM LOADING AREAS
26 AWG SINGLE JACKET FIGURE 8
BKTS-100
SPAN LENGTH
(Feet)
50
75
100
125
150
175
200
225
250
275
300
325
350
375
400
425
450
475
500
SAG UNDER
EXPECTED TENSION
STRINGING
STRINGING SAG MEDIUM LOADING UNDER MEDIUM LOAD
TENSION(Lbs.) (Feet) - (Inches) (Feet) - (Inches)
(Lbs.)
500
0
3
0
8
615
500
0
7
1
4
670
500
1
1
2
2
725
500
1
8
3
2
777
500
2
5
4
3
825
500
3
4
5
6
870
500
4
4
6
10
911
500
5
5
8
4
948
500
6
9
9
11
983
500
8
2
11
8
1014
500
9
8
13
6
1043
500
11
4
15
5
1070
600
11
0
16
0
1201
600
12
7
17
11
1229
700
12
3
18
6
1352
700
13
10
20
6
1381
800
13
7
21
2
1500
900
13
6
21
11
1613
900
14
11
23
10
1643
UNLOADED SAG
AFTER STORM
(Feet) - (Inches)
0
5
0
9
1
3
1
11
2
8
3
6
4
7
5
9
7
0
8
5
9
12
11
8
11
5
13
0
12
10
14
5
14
3
14
4
15
9
BKTS-200
SPAN LENGTH
(Feet)
50
75
100
125
150
175
200
225
250
275
300
325
350
375
400
425
450
475
500
SAG UNDER
EXPECTED TENSION
STRINGING
STRINGING SAG MEDIUM LOADING UNDER MEDIUM LOAD
TENSION(Lbs.) (Feet) - (Inches) (Feet) - (Inches)
(Lbs.)
500
0
5
0
9
630
500
0
11
1
7
690
500
1
7
2
7
745
500
2
6
3
9
794
500
3
7
5
1
838
500
4
11
6
8
876
500
6
5
8
4
908
500
8
1
10
3
937
500
10
0
12
4
962
600
10
1
13
0
1100
700
10
3
13
10
1231
700
12
1
15
11
1259
800
12
3
16
9
1385
900
12
6
17
8
1508
900
14
3
19
9
1537
1000
14
5
20
8
1657
1100
14
9
21
7
1774
1100
16
5
23
8
1803
1200
16
8
24
8
1919
UNLOADED SAG
AFTER STORM
(Feet) - (Inches)
0
6
1
0
1
9
2
8
3
9
5
1
6
7
8
3
10
2
10
4
10
7
12
5
12
8
13
0
14
9
15
1
15
6
17
2
17
7
NOTES: Medium ice loading is defined under NESC Rules 250 and 251 as 0.25 inch radial thickness
of ice and 4 PSF horizontal wind pressure at 15º Fahrenheit. Stringing tensions are at 60º (F).
04/08/04
Page 12 of 12