ICPTest_877 10 29 2012_ pdf

ICP Test Report Certification Packet
Company name :
Littelfuse, Inc.
Product Series:
Compact 3.6 x 10 mm Single Pigtail Fuse
Product #:
877xxx Series
Issue Date:
October 29, 2012
It is hereby certified by Littelfuse, Inc. that there is neither RoHS (EU Directive 2002/95/EC,
2011/65/EU)-restricted substance nor such use, for materials to be used for unit parts, for
packing/packaging materials, and for additives and the like in the manufacturing processes.
In addition, it is hereby reported to you that the parts and sub-materials, the materials to be used
for unit parts, the packing/packaging materials, and the additives and the like in the manufacturing
processes, are all composed of the following components.
Issued :
<Global EHS Engineer >
(1) Parts, sub-materials and unit parts
This document covers the Compact 3.6 x 10 mm Single Pigtail Fuse, RoHS-Compliant
series products manufactured by Littelfuse, Inc.
< Raw Materials Used
Please see Table 1
(2) The ICP data on all measurable substances
Please see appropriate pages as identifed in Table 1
Remarks:
Form 585-047 Rev. A
1
2/21/06
Table 1: List of Raw Materials covered by this report
Total Parts
1
2
3
4
5
6
Raw Material Part Number
YJ50/YJM (909-444)
692481
934-065
7132 (425672)
DRAG****
648112-001
Raw Material Description
Ceramic Base - Body
Solder
Cap & Lead wire (base & plating)
Ink-Black
Element - Wire-Sn Plated Ag/Cu
Ceramic Yarn
2
Page(s)
3-13
14-18
19-22
23-31
32-41
42-47
Test Report
Applicant:
Number : TWNC00235575
Littelfuse Philippines Inc.
LIMA Technology Center, Lipa City,
Malvar, Batangas
Date
: Dec 08, 2011
Sample Description:
One (1) group of submitted samples said to be :
Part Description
: Solder
Part Number
: 692481
Date Sample Received
: Dec 05, 2011
Date Test Started
: Dec 05, 2011
Test Conducted :
As requested by the applicant, for details please refer to attached pages.
Authorized By:
On Behalf Of Intertek Testing Services
Taiwan Limited
K. Y. Liang
Director
This report shall not be reproduced
except in full, without the written
approval of the laboratory.
Page 1 of 5
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00235575
Test Conducted
(Ⅰ) Test Result Summary :
Test Item
Heavy Metal
Cadmium (Cd) content
Lead (Pb) content
Mercury (Hg) content
Chromium VI (Cr6+) content (mg/kg with 50cm2)
Result (ppm)
Silvery Metal
ND
200
ND
Negative (< 0.02)
Remarks: ppm = Parts per million based on weight of tested sample = mg/kg
ND = Not detected
<
= Less than
mg/kg with 50cm2 = milligram per kilogram with 50 square centimetre
Negative = A negative test result indicated positive observation
was not found at the time of Test.
Responsibility of Chemist : Irene Chiou / Kevin Liu
Date Sample Received
Test Period
: Dec 05, 2011
: Dec 05, 2011 To Dec 08, 2011
(Ⅱ) RoHS Requirement:
Restricted Substances
Cadmium (Cd) Content
Lead (Pb) Content
Mercury (Hg) Content
Chromium VI (Cr6+) Content
Limits
0.01% (100ppm)
0.1% (1000ppm)
0.1% (1000ppm)
0.1% (1000ppm)
The above limits were quoted from 2002/95/EC and amendment 2005/618/EC for
homogeneous material.
Page 2 of 5
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00235575
Test Conducted
(Ⅲ) Test Method:
Test Item
Cadmium (Cd)
content
Lead (Pb) content
Mercury (Hg)
content
Chromium VI (Cr6+)
content
Test Method
With reference to IEC 62321 edition
1.0:2008 in clause 8/9/10, by
microwave digestion until the tested
samples are totally dissolved and
determined by ICP-OES.
With reference to IEC 62321 edition
1.0:2008 in clause 8/9/10, by
microwave digestion until the tested
samples are totally dissolved and
determined by ICP-OES.
With reference to IEC 62321 edition
1.0:2008 in clause 7, by microwave
digestion until the tested samples are
totally dissolved and determined by
ICP-OES.
With reference to IEC 62321 edition
1.0:2008 in annex B, by boiling water
extraction and determined by UV-Vis
spectrophotometer.
Reporting Limit
2 ppm
2 ppm
2 ppm
0.02
mg/kg with 50cm2
Remark: Reporting limit = Quantitation limit of analyte in sample
Page 3 of 5
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00235575
Test Conducted
(Ⅳ) Measurement Flowchart:
Test for Cd/Pb/Hg/Chromium (VI)
Reference Standard:IEC 62321 edition 1.0:2008
Sample preparation
Take sample and immerse into Aqua Regia, start to strip plating layer
Stop the stripping procedure upon color change completely
Take the Aqua solution as plating component and stripped body as substrate component
Cd/Pb/Hg
Cr
Polymers /
electronics
Metal
For different
material, digest
the sample with
*1
appropriate acid
By spot test
Negative
Confirm the tested
samples are
totally dissolved
Make up with
deionized water
6+
*2
Weigh sample
and add
alkaline
solution
Get 50cm2 sample
Definite temp.
extraction
By boiling water
extraction
Cool and filter
the extract
Analyzed by ICP-OES
Make up with deionized water and add
diphenyl-carbazide solution
Remarks:
*1: List of Appropriate Acid:
Material
Polymers
Metals
Electronics
Analyzed by UV-VIS
Acid Added for Digestion
HNO3,HCl,HF,H2O2,H3BO3
HNO3,HCl,HF
HNO3,HCl,H2O2,HBF4
*2: If the result of spot test is positive, Chromium VI would be determined as detected.
End of Report
Page 4 of 5
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00235575
Test Conducted
Photo
Page 5 of 5
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
nov'
TESTREPORT
NO.:4002E11121307-2R02
page1of4
Oa!aiDec15,2o11
Customer:SuzhouFuHongElectrcnic
IndustfialCo,
Ltd.
Addrgs8:NO.89WElDUROAD,WANGTING
TOWN,
XTANGCHENG
D|STR|CT,
SUZHOU,
CHTNA
Reporton th6 3ubmittedssmplesaidio be
Samplename:Fusoscoppershell
llodol: /
Material:/
D$cription:/
Buyea:/
supplier:/
Sa|nplerecelveddate:Dec.13,2011
Tcatlngp€riod:FrcmDec.13,2011
to Dec.15,2011
T€tino Reau6ted
As specined
by client,to delermine
theL€ad,Cadmium,
Mercrry& Hexavatent
Chrcmium
contentin thesubmitted
samptein
accordancewilh Direclive2002/95/EC(RoHS).
Tcstindmethod:
Testing llem
[,leasudng
inslrument
MQL
Lead (Pb)
EC 62321:2008,seclion9
ICP-OES
2mglkg
cadmium(Cd)
(Hg)
Mercury
EC62321:2008,sectionI
ICP€ES
2 mg/kg
EC62321r
2008,section7
rcP-oEs
2 mg/kg
(Crl'I)
Chrom'um
EC62321:2008,
AnnexI
0.02mg,a(g'
lsg
-'0.02mg/kgreturs
10lheMQLofsample
extEction
tiquid.
99!s!.c!i9!j
-ffien tesiedas specifred
thesubmitted
sample
complied
withtherequircments
of commission
Decision
of 18Aug2005
amending
Directive
2002l95/EC
nolified
lnderdocument
2005/618/EC
ILS, PLEASEREFERTOTHE FOLLOWINGPAGE(S)'**'
',:,"il:::i"
ryf4
,3ffi::::1,,44
hrn
lffH*"",",We-i
S}'EI{ZN€N AOV TGSTINGT€CHNOlOGY CO.,L'D.KUNSHAN EiANCH
Hotllne
86-512-551
80 0 0
nov
6
TESTREPORT
NO.:4002E11121307-2R02
Add the digestionsolution;the
vesselis heatedLrntillhe sampl€
AddHrO,unlilthesampl€is clear
F;;1.-F;;,",..;-1.-
Cooling
thevessel,fllleriwashedand
filledto themarkwithdistilled
water.
{Melalsubslrat€)
Add lhe digestionsolution,clos€
The sampleis digestedin the
the macrowavevess€|.
micrcwave oven following a specific
program.
decomposilion
Coolingthe vessel,filter washedand
filled to the mark with distilled water.
Remove
thesample,
andcool
lhe beakerlo rcomtempefalure,
anddo1ie colorreaction
Heal50 mL ofDlwaterin lhe
beakertoboilingfor 10 min
Testthesamplesolution
andlhe 0.02
mg/kgstandard
solution
by UV-VIS.
To Detemine
(Praring)
andl\rercury
Content:
coor,ns.
nrr",
*""n"0 r"o
_____-l
""0 |
I
tothemark
withDtwater
I
,l o*o
-ill_.;*--;-l
I r*r.r*t
|
STIENZH€NAOV TESIING T€CIII{OLOGYCO.,lIO,KUII9HAN BFANCH
Hdpi/j,w.o{,6n
|
-.-
|
Hotline
8 6 - 5 1 2 " s 5 18 0o O 0
nov.
TESTREPORT
NO.:
4002E11121
307-2R02
Date:Dec.15,2011
Page3 ol4
5. ToDetemineHexavalent
Chromium
Contentln
colorless
andcolored
ctlromate
coalingon metals: (Plating)
'' ',.'1
re$eoovr I r
s.t sw-resi (M&
lflhe lest resullis positive,
the sampleis considered
1o
havehexavalenlchromium
Boiling- waieF extraction
procedure
shallbe usedto
and the 0.02 mg/kg
lfthe€ isrnterference
orI rshardto decide*terhel
lhesamplehavethehexavalent
chrcmium
5 2 BoilingwEter-en€ction
Takethe (5015)cm'z
samplein thebeaker.
Heat50 mlof Olwaterin the
beaker
lo boilingfor 10min
Remove
he sample,
andcool
lhe beaker
1oroomtemperature,
anddo thecolorreaction
Testthe samplesolutionand the 0.02
mg/kgstandardsolutionby UV-VIS.
Srmple d93cription:
Coppershellsubslrate
Leadwle Platrng
Unil
24
CoppershellPlaling
RoHS
Limit
2-3
24"
Lead(Pb)
mg/Kg
1000
N.D.
2.5
40.0
N.D.
Cadmium
{Cd)
mg/kg
100
N,D.
N.D.
N.D.
N.D.
(Hs)
Msrorry
(Crvl)
Chromium
mg/kg
1000
N.D,
N.D,
N.D.
N.D.
mg/Kg
1000
Negative Negative Negalive
Negative
SH!NZHEN AOV TESTINGTCCTNOIqGY CO.,L}D,KUNSHAN BFANCH
n
Hotline
86'512^551
80 0 0
nov.
TESTREPORT
NO.rA002E11121307-2R02
Dat€iOec15,2011
-The new RoHSdi.ective2011/65/EU,
on Jul 21, 2011comeinto force,on Jan.03, 2013the fomat imotementation.
Dircctive
2002l95/ECshallbe reoealedsimultaneouslv.
Sp€cim€ns,wnicnrequestedto determineLead,Cadmiumand l4ercuryConlent,havebeendissotvedcomptetety.
-mg/kg=ppm
-N.D.=notdetected(<tVoL)
-MQL=l'rethodOuaniilationLimit
-Negalive=Abs€nce of Cr (VI);
Posilive=Prcs€nce
of Cr (VI)i
Uncedain=c€n noi ve fy whetherthe samplehaveHexavat€nt
Chrcmium by spoliesl.
(The tested s€mple should be furlher venfed by boiling-waterextradion
method if the spol test result is uncertainor
-'The test is basedon the followingassumption:Thesampteptatingis a singtetayerandeach pad is unifom. The test resutt
maybecannolslandior rhe physicartruthof sampleplating.
Photog.aphofSample
"'End of Repod"'
S'iE'!ZH€N AOVT€STING TECXNO!OGYCO..lIO,KUNSHAN ABANCH
Hh,:/fuloi6n
n
Hotline
86-512-551
80 0 0
Number : TWNC00256916
Test Report
Applicant:
Littelfuse Philippines Inc.
LIMA Technology Center, Lipa City,
Malvar, Batangas
Date
: May 16, 2012
Sample Description:
One (1) group of submitted samples said to be :
Part Description
: Ink
Part Number
: 425672
Date Sample Received
: May 10, 2012
Date Test Started
: May 10, 2012
Test Conducted :
As requested by the applicant, for details please refer to attached pages.
Authorized By:
On Behalf Of Intertek Testing Services
Taiwan Limited
K. Y. Liang
Director
This report shall not be reproduced
except in full, without the written
approval of the laboratory.
Page 1 of 9
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00256916
Test Conducted
(Ⅰ) Test Result Summary :
Test Item
Heavy Metal
Cadmium (Cd) content
Lead (Pb) content
Mercury (Hg) content
Chromium VI (Cr6+) content
Polybrominated Biphenyls (PBBs)
Monobrominated Biphenyls (MonoBB)
Dibrominated Biphenyls (DiBB)
Tribrominated Biphenyls (TriBB)
Tetrabrominated Biphenyls (TetraBB)
Pentabrominated Biphenyls (PentaBB)
Hexabrominated Biphenyls (HexaBB)
Heptabrominated Biphenyls (HeptaBB)
Octabrominated Biphenyls (OctaBB)
Nonabrominated Biphenyls (NonaBB)
Decabrominated Biphenyl (DecaBB)
Polybrominated Diphenyl Ethers (PBDEs)
Monobrominated Diphenyl Ethers (MonoBDE)
Dibrominated Diphenyl Ethers (DiBDE)
Tribrominated Diphenyl Ethers (TriBDE)
Tetrabrominated Diphenyl Ethers (TetraBDE)
Pentabrominated Diphenyl Ethers (PentaBDE)
Hexabrominated Diphenyl Ethers (HexaBDE)
Heptabrominated Diphenyl Ethers (HeptaBDE)
Octabrominated Diphenyl Ethers (OctaBDE)
Nonabrominated Diphenyl Ethers (NonaBDE)
Decabrominated Diphenyl Ether (DecaBDE)
Halogen Content
Fluorine (F)
Chlorine (Cl)
Bromine (Br)
Iodine (I)
Result (ppm)
Black Paste
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
Page 2 of 9
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00256916
Test Conducted
(Ⅰ) Test Result Summary :
Test Item
Result (ppm)
Black Paste
Phthalates
Di(2-ethylhexyl) Phthalate (DEHP)
Dibutyl Phthalate (DBP)
Benzyl Butyl Phthalate (BBP)
Others
Hexabromocyclododecane (HBCDD)
ND
ND
ND
ND
Remarks: ppm = Parts per million based on wet weight of tested sample =
mg/kg
ND = Not detected
Responsibility of Chemist : Irene Chiou / Kevin Liu / Cathy Chen
Date Sample Received
Test Period
: May 10, 2012
: May 10, 2012 To May 16, 2012
(Ⅱ) RoHS Requirement:
Restricted Substances
Cadmium (Cd) Content
Lead (Pb) Content
Mercury (Hg) Content
Chromium VI (Cr6+) Content
Polybrominated Biphenyls (PBBs)
Polybrominated Diphenyl Ehters (PBDEs)
Limits
0.01% (100ppm)
0.1% (1000ppm)
0.1% (1000ppm)
0.1% (1000ppm)
0.1% (1000ppm)
0.1% (1000ppm)
The above limits were quoted from 2002/95/EC and amendment 2005/618/EC for
homogeneous material.
Page 3 of 9
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00256916
Test Conducted
(Ⅲ) Test Method:
Test Item
Test Method
With reference to IEC 62321 edition
1.0:2008 in clause 8/9/10, by
Cadmium (Cd)
microwave digestion until the tested
content
samples are totally dissolved and
determined by ICP-OES.
With reference to IEC 62321 edition
1.0:2008 in clause 8/9/10, by
Lead (Pb) content
microwave digestion until the tested
samples are totally dissolved and
determined by ICP-OES.
With reference to IEC 62321 edition
1.0:2008 in clause 7, by microwave
Mercury (Hg)
digestion until the tested samples are
content
totally dissolved and determined by
ICP-OES.
With reference to IEC 62321 edition
6+
Chromium VI (Cr ) 1.0:2008 in annex C, by alkaline
content
digestion and determined by UV-Vis
spectrophotometer.
With reference to IEC 62321 edition
1.0:2008 in annex A, by solvent
Polybrominated
extraction and determined by GC-MS and
Biphenyls (PBBs)
further HPLC-DAD confirmation when
necessary.
With reference to IEC 62321 edition
Polybrominated
1.0:2008 in annex A, by solvent
Diphenyl Ethers
extraction and determined by GC-MS and
(PBDEs)
further HPLC-DAD confirmation when
necessary.
With reference to EN 14582:2007 by
Halogen Content
calorimetric bomb with oxygen and
determined by Ion Chromatograph.
With reference to EN 14372: 2004, by
Phthalates
solvent extraction and determined by
GC-MS.
With reference to USEPA 3540C, by
Hexabromocyclodode
solvent extraction and determined by
cane (HBCDD)
GC-MSD.
Reporting Limit
2 ppm
2 ppm
2 ppm
1 ppm
5 ppm
5 ppm
50 ppm
10 ppm
10 ppm
Remark: Reporting limit = Quantitation limit of analyte in sample
Page 4 of 9
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00256916
Test Conducted
(Ⅳ) Measurement Flowchart:
Test for Cd/Pb/Hg/Chromium (VI)/PBBS/PBDES Contents
Reference Standard: IEC 62321 edition 1.0:2008
Sample preparation
For non-metal part
For metal part
Take sample and immerse into Aqua Regia, start to strip plating layer
Stop the stripping procedure upon color change completely
Take the Aqua solution as plating component and stripped body as substrate component
Cd/Pb/Hg
Cr
Weigh sample and
add organic solvent
By spot test
Negative
Confirm the tested
samples are
totally dissolved
Make up with
deionized water
PBBs/PBDEs
Polymers /
electronics
Metal
For different
material, digest
the sample with
*1
appropriate acid
6+
Get 50cm2 sample
By boiling water
extraction
*2
Weigh sample
and add
alkaline
solution
By Soxhlet
extraction or
Solvent extraction
Definite temp.
extraction
Cool and filter
the extract
Analyzed by ICP-OES
Concentrate the
extract and make up
with organic
solvent
Analyzed by GC-MSD
Make up with deionized
water and add diphenylcarbazide solution
Analyzed by UV-VIS
Remarks:
*1: List of Appropriate Acid:
Acid Added for Digestion
Material
Polymers
HNO3,HCl,HF,H2O2,H3BO3
Metals
HNO3,HCl,HF
Electronics
HNO3,HCl,H2O2,HBF4
*2: If the result of spot test is positive, Chromium VI would be determined as detected.
Page 5 of 9
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00256916
Test Conducted
(Ⅳ) Measurement Flowchart:
Test for Halogen Content
Reference Standard:EN 14582
Sampling/grinding or
cutting
Add absorbent in a
combustion flask &
place weighed sample in
equipment
Fill oxygen into
calorimetric bomb
Ignite then leave the
bomb at room
temperature
Transfer the absorbent
into a volumetric flask
Make up with deionized
water
Analyzed by ion
chromatography
Page 6 of 9
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00256916
Test Conducted
(Ⅳ) Measurement Flowchart:
Test For Phthalates Contents
Reference Method: EN 14372: 2004
Sampling/grinding or
cutting
Weigh sample and add
organic solvent
By solvent extraction
Concentrate the extract
and make up with
organic solvent
Analyzed by GC-MSD
Page 7 of 9
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00256916
Test Conducted
(Ⅳ) Measurement Flowchart:
Test For Hexabromocyclododecane (HBCDD)
Reference Standard:USEPA 3540C
Sampling/grinding or cutting
Weigh sample and add organic
solvent
By soxhlet extraction
Concentrate the extract and
make up with organic solvent
Analyzed by GC-MSD
End of Report
Page 8 of 9
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00256916
Test Conducted
Photo
Page 9 of 9
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
,fl.d,+E+
TestReport
trTxlt*.5G
nown
ForOue5ll
PleaseCo
ithscs
f i , S ( N " . ) , c E / 2 0 1 2 / ] 0 8 3 5 E 4 ( D a t e ) : 2 0 r 2 l 0 1 / 1 1 F & ( P a 8 e ): r o f r o
ELSCHUrcMELEKTROSCHUTZI{OMPONENTENBAU
GIIBH
CEI'ERBESTR,ASSE
87, D-98669 \EIISDORF, GE&UA\Y
ideltified
Validit
68P 't&, -R& *,P +*&lf*P
hylon behatf of rle client
iiSZ,f*(s.'pl" D€s.ripr ion)
if gd&(style/I r€b N".)
4 , & . E ( c o u n t i y" f o r i s i n )
{t4 A S (s.'!1" Rec€ivingDate)
,tlHS&l(Tesrihc P€.i od)
ji,t,+ jR(rest Resrlts )
'
|l]
*AnT
(The folloeins
saDples ra./rcre
srbeittcd
t|| fl m
and
as):
SILIER
PIATED & PURE SILVM
$'IRES
',tr+*sR
(PLEASEREFERTo PAGEs)
(GERI4A\"Y)
{EE
2012/0t/04
2 0 1 2 / 0 t / 0 4 ' f o2 a t 2 /a t / t l
5 + X .F - F { P r e a , e r e f p - r o r e x r ! a s c ! r
(Alw4?\
C$Fdft.|nd
chrnLd lrbor.tlry - Trlpd
?
r'-;.!liiri
i
.:
i
).:!tli
p3G)6rad rb s rad Gpon€n'orF
ir. r.r rl!tul.
McmbForfie !69 Gouo6c! Sr,.r
,fla,+E+
TestReport
! t 4 5 ( N o .) : c E / 2 0 I 2 l l o d J s
E q ( D a r " ) : 2 0 1 20 I / l l
E*{pase) ,2 oi l0
ELSCHUKOM
ELU(TRqSCHUTZXOMPONENTENMU
GVBH
GENERBESTI{ASSE
87, D-98669'IIEIISDORF,CE!.T{Ar\Y
It**(T.st
]||lt[ttl||||fiml|!
R e 6 u lt s )
jrl:i *r'.i (PARTNAME)No.l :
ie;qma&ein&
(6{t,r)
(Jt6t ) (MTXED
ALLmLoRtltErArNrm
( INCLUDINGTIiE PLATINC LA\'ER) (6 TYPES))
r|iiit E
ttt.ttrl
Etl{N
*ittri
+lt
(Urit)
,fr / cadniun (cd)
(rDL)
+arEc 623zLt2oo8r;i, 4&,S*{
6€*.F+&4t*.*d,h;Fl.
/ q'ith
refe.ence
perforfted
S
/ Lead (Pb)
to IFC 62327t 2008 anl
6y ICP-AFS.
++IEc 6232rt2008ti1, rr t$A*t
+t*fr+**i*,;*d&;il.
/ {i ih
.eference to IEC 62321: 2008 and
by ICP-,ES.
terforaed
*- / vercury (Hs)
: 2008t&,'r€E*4
++ lEx.62321
+€ {/F + **t rt ;* d,*birl. / $i r1'
reference to IEC 62321: ?008 and
perforned by tCP-r{XS,
,i.flJ'
/ Heaav,lent chroni!n c.(vI)
++ \F: 62321.2OO8li*, t)a.,fr
*+
/ with fefe.€n€e ro IEc
RliAtll.
6 2 3 2 1 . 2 i A B a n d p e r f o r m e db y
B o iI i n s s a t e r e x t . a c t i o n M € t h o d . #
}fr.+B**
sulfonates
/ Perrruo.oocrane
nglka
(PF!S-Acid. Uetal salt
t+us
EPA3540C:1996tii, 'lil
IO
iE,9*f1[-r*&}f,4
an+,t,4*69'
/ t r i t h r e f e r e n c e t o u s E P A3 5 4 0 c
1 9 9 6n € t h o d f o r P F o SC o . l e . l .
Analysis was perlorned by tClMS.
an+6.(J+) / PFoA(cAsNo.: 3356?
r)
++US EPA3540c:l996tt!,
,Xtl
&Eif 1{r*{,*fl an+d(n) }f
/ w i t h r e f e t e n c € t o U S E P A3 5 4 0 C
1 9 9 6e e t h o d f o r P F O AC o n t e n t .
Analysis was perfofned by rc/MS.
i j :i :r l , ]. r : . a i i . ; ; r t i ]
c o n o a .t y r r , : 1 r 1 , ri!' _, r r l - J n
iy $qd rob cene6cdidroc d s
onlysndwibinlh.imlsoic€nls'ns
pelsr reded rhE bd rcpod Enid be
1, . r, rjr,!*.
l0
s*
(Resql t)
No,1
rfla+E+
ft4(No.) : cE/20I2lr0835
Test Report
E J q ( D a r :e2)0 t 2 l 0 t
E * . t e , B " ,/ 3 . r
ELSCHUKOM
ELEKTROSCHUTZKONPONENTENBAU
CMBq
GMERBESTRASSE
87, D-98669 !'EIISDORF, GERMAIr\
d{t
E
lll
+4o
,{fi,t*
( U n it )
( R e s u1 t )
(IDL)
No.l
/ uonobronobiphenyt
:;Ad*
qA#tri
/ Dib.onobipltenyl
/ T r i b r o n o b ip h e n y l
/ T e t r a b r 6 n o bLo h e n v l
I*#Xi
/ P e n t a b r o n o br o h e n ! I
/ Hexabronobiphenyl
?!4$it
+iASf
/ H e p r a b . o n o bpi h e . y 1
^itrfi A / o.rabronobipheDyl
/ Nonabromobipheryt
4)qS*
/ D e c a b r o n o bpih e n y t
+;ASf
*trEc
/ suo of PBDES
t*AS.t&t"
-;ASf!{
/ M o n o b r o n o dD
i hehvl ether
=-r[#*e
:;A#+a{
/ D i b r o n o d ip h e n y l e t h e r
/ ' l r i b r o d o d i p } e n v l er h e .
B,*SiFa*
/ Tet ra6.onodi phe.vl erher
i;*Sxad
'r*S*a*
/ P e . r a b r o m o dDi h € " v l e t h e r
/ H e a a b r o n o dpih e r v t e r h e r
-k;A#Xa{
/ H e p t a b r o m o d iD h € n v l e t h e r
,\;*SXa{
/ o c r a b r o n o dD
i he.vl ether
,L;i#*e
i henvl etler
i N o n a b r o m o dD
+&#ii4
/ D € c a b r o n o d i D h e n velt h e r
623211
zoo$iiF, ,tfu|aE
+8dlf :*d,&jrl. / $ith rererence
ro IEC 62321:?008 and perforned
by rc/MS.
5
5
5
5
5
5
5
5
5
5
5
5
5
5
a* / s"l.s."
(fr.) / Halogen-Floo.ine(F) (c{s
6*
No.: 14?6?_94-8)
(5.) / Haloeen-chlo.ine (cl) (cAs
6*
! o . : 2 2 5 3 71- 5 - r )
& * ( * ) / H a l o r e n - B r o n i n e( B r ) ( c A S
l{o.: 10097-32-2)
50
ng/18
vx&+8fr
ltBs vt r4s82:2007,
50
/ sirh reference to Bs EN
{r}*t.
I 4 5 8 2 r 2 0 0 7A. n a l y si s v a s
50
(I) (cAS
6fr (dU / Halocen-lodine
No.: 14362-44-8)
conFiv;"
r 1 llu.,[r'r,
l: i/irr.r I i.tl
lt!,lr'i
oyglbredbb6ai.'alcondloisds
50
hrr.(s) rssbd rh s resr €pon ennd
lLr Lt[]!.
iq
3pdJb't}6lobc€da^dhsdocu
b
r**
,illt,rl
EIE{I
/ su! of PBtss
t*t**'ts
:14#*
:i*#f'
(Iethod)
ro
l ]tl|
]t
,F{a+E+
ff6(No.)
Test Report
: CE/2012l10835
aBlJzr.)
. 20L2/ot/71 Ftk(pare) : 1 of r0
EI-SCHIrXOI1I
ELEKTROSCHUTZ(oVPO|iENTU\]BAU
GttBH
GEI/ERBE.STT.ASSE
87, D,98669 VEITSDORF.GERVIIY
[]tl||t][]tI|
fiii(N.t.):
l . m g l k g: p p m ;0 . | w t %= l o o o p p n
2 _ n _ d . = N o r D e t e c t e d( * . t A r r )
3 - M D L: M e t l o d D e t e c t i o n L i r i i ( r l t l A ; { t s 1 8 1 6 )
4. '- = Not R"sulated (Sli,+&.6)
5 . r ' = Q u a t i t a t i v e a n a L y s i s( N o u n i t ) _ € , B r ) * f ( * + & )
6. #:
a . P o s i t i v e b e a ! s t l e p . e s e n c eo f C r V t o n t h e r € s t e d a r e a s
(po s i t i ve *,F rq,lit E q.tF jq r{ ,r{l rS)
b . N e g a t i v e n e a n s t h e a b s e n c eo f C i V I o n r h € r e s t e d a . e a s
( Nesat i ve i nr::tl*, E 4 t.tA ).14 'r1l1g )
T h e d e t e c t e dc o h c e n r r a t i o ni n b o i l ] n a - e a r € r - e x r r a c t i o sno l u t i o n i s € q u a l o r g r € a r e r t h a b 0 . 0 2
m A l k gw i t h
50 cn: tested ar.a". / li6;i{XA>0.02
nslka *iih 50 cm, (tested
z. tte.i,tlS{r.'Af
;F./.**isArxl:{,, *E+titi,sA,tt:ri}:+.Tftt 4 +1Erll+-ttlt aiAE.
(The sanples sas/were analyzed on behalf of the atfricant
! e s u l t s w a s / w e r eo n l y g i v e n a s r t e i n f o . n a t i t y v a l u e , )
PFos++*d,(R"f
Inf orlation)'
"'.o"€
(1) riitrrf rTfi.'|tsld.&n,r+r+4rrf,
as mixing sanpre in one resrine.
The above
!A+ 2oo6trzztEa (Di rect iae 2006/t2ztw)
d.Ee,Ed,rlE*tla+,i6d.n,+0.
005%.
(May not be placed on the market o. used as a sDbstance o. consrituent
€qual io or nigh€r than 0.005 % by nass.)
of prepararrons
(2rtit{ttX4n&*fi&}.ei+d."%d.6s{.*{r1+;1!i*€1+}aX*Jt+ApFosi.4t?J*fi}.e.t&r€t6€};l4pFosEE
,i.&+,i!d.i,ifo.r%,6*r&€d.4{tti.4rf. {,RprrsaAt*f + 6E*;Ad.Ji;Aruc/.,.
(Maynot be placed on ihe na.k€t in seni-linisned prodocts or articles, or pa.ts rhereof, if
ure
c o n c e n t . a t i o n o f P F O Si s e q u a t r o o r h i g h e . t h a n 0 . 1 % b y n a s s c a l c ! l a t e d s i t h r e f e r e n c e t o t l e n a s s o f
s t . u c t u r a l i y o . f r i c . o s t r u c r u r a l l y d i s r i n . r p a r r s t ! a i c o n t a i n P F o . so r , f o . r e x r i t e s o r o t h e . c o a r e d
naterials,
if thc anoun! of PFOSis equal to o. hiahcr than Ug/nr of thc coated nateriat.)
c o m p a ityr : ; r , r ; : i r l , , ; - f i t . r l J r . n i r r , . r , , t i i
Ltlttr
1i., r".l,r!/,)!
ont andub'n ihsh b orc en'3,ns
-.4ttr
- ! . ! , , : r r i r l l i - I. c i e o a F i
-:.r ;::rlnti,,;i+46iDr,ssr7
l
,rla#+
TestReport
ft,q(No.) : cE/20r2lr0835
E S ( D a t e ) : 2 0 1 2 1 0 1 / 1 1F * . ( p a s € ) : 5 o r l 0
EI-SCHIXOi,I
ELEKTRO€CHUIZKNTPONENTENMU
CVBH
GEIIERBESTInSSE
87, D 98669 IEIT,SDORF.GERILUY
tl&4!t(styl./I
[t[t
t.' N".)
(B-1) 101. 014
-silver
plated coFpe.{tre-Cu. Ag - - %
(B-2) 101. 0131. - - - - -pure silve. sire-Ag l()()()
( B - 3 ) 1 0 1 . 0 1 2 3 . 0- - - - s i l v e r
platcd purest nickct vire-Ni99.98%. AgI%
-silve.-copper alloy plated cotpe. clad vire-Elcon D,
(B-4) 10r,0182.0 - -silver
(B 5) 101.0120.0
p l a t e d c o n s t a n t a nw i i € - C u N i 4 4 , A A S %
( B - 6 ) 1 0 1 . 0 1 5 1 . 0- - - - c o p p e r - n i c k e t 4 4 a l l o y s v e r p l a r e d s i . e - c u N i 4 4 ,
c o D o a n tv l r I t ! . , r - N ' | , r " l : l , i l l l i
:. ! 1 1:;!1,1\
p sG)rssr€drh s€d Gpon€ind e
rlllrillrl.
!
ont 3nd*ii'n rh. hrs or c €nr s 'ns
ri.:l,;l-":Iq:j1
tl|
|||ll
,fl-d,#+
Test Report
f i { 5 ( N o . ) : C E l 2 0 1 2 l l o s 3 s E S ( D a r e ): 2 o t z l 0 r / t t F # ( p a s € ) :
ELSCHUI{OM
ELEKTROSCHUTZKOMPONENTENBAU
G\!BH
GEWERBESTRNSSE
8?, D 98669 WILSDoII, CERMA\Y
6
0 f l 0
[l|[]|l
r) ll?cr,-F $,EEn zI*1+ ' *.& aia*t+
. ( *1' j&d *tt *hrl. ) / Thes€samDtes
!,€€
d€sotuedrolrrryby p.e-condrumhgmethooaccodinglo betN nowchad. cP re€tmethodexcludeo
2) r.lri^l:
yang
$e ! / Naheotlneps6onwhomadenEsuremed:ctimbgreal
3) ir'13{I i ^ : tl4* / Nameof the pe6on in chargeormeasu€m€nlrTroychans
tr*. {rtt*s
/curing. p€galaton
iqr{.&,cf ! / sdde MeasuEmenl
&lf;F n l*'.g6tt{ f, 6 }xn!trai&it,tirt /LoeTt
4rt/!inlt n.i'la{&,aib /
4,;) /Acid dig€slion by suitabte acid dependedon
dtrerenlsahdemaledat{asbetowiable)
MiorcMve digestion with HNO3/HC|/HF
,"rl4rOf jit& jt.li,lilt +
C( / H€i to appropriate
1)
2)
f [*a{*4+*it{rtc
/ AlkaliF6ion
/HCltod$d€
/ rcP,aEs
f!911L / samdeMatedal
51eel,@pper,allnirum, solder
&ltgti
ta{*tt
;filt&AJlfi / DiqesL|onAcd
-t+, 4la{,!lt, nn*, el,,k /
Aa@ reoia. HNO' HCl. HF. H,O,
rra{,Inc / HNoJftF
A, J6,€, nit /
Gold,olalinum,
Dalladium,
ceramic
,i(f rf 7h-ir,g t.rLrlf,.' I
irl#B*i{Aftrcnm 6id
rti!€ /HNOr
&E / Plaslic
4?,*i&8tt$ / coot,
fherdigestate
lhrough
liher
*d, t{"*,
s!t, td / H,so. Ho,. HNorhcl
,! \'efi*1eti*l+
/ Anyacldlo lotaldig€Gtion
j i i r i r +
r i l , i ,
! . r 1 r . t p . l i , . 1 , i f i ' ! ! l .
rhcdddneiiAs€dbysgcompa^ys!b4d{ob6ai..a|condloi3ds
ab6o6anceat a/ronmby
UV-VIS
t]n]l
,F{a*R+
Test Report
iEIS(No.) : cE/2012l10835
E rr?(Dare) : 2012l01/11 F&(P,s")
ELSCHUKOMELEI$ROSCHUTZKOIIPONENTENB,qU
GMBH
CETERBESTRA.SSE87, D-98669 VEIISDORF, CER[{AI\'Y
t ttt*/t
rtt+4+f
l
*,aE / PBB/PBDE
anatyticat
FLOWCHART
a }l{,/\l
I a_i9*, / Nameoftheperson
whomademeasuremenl:
RomanWonq
r,$Ji( frt ^ : &+le / Nam€of thepersonIn chargeof measurement
TrcyCha;g
n^ ld,ElF / Firstlestry proce.s------------f
....,---.
prccess
€*,E&*€F / OptionalscE€n
-. -,t
*{.€,S / Confimation
orccess
:l
Scre€n
analysis
/ ,, rfi+rt
I
I
sample
erlraclion
*s+*/
Soxhlet
melhod6i,+tx;*
Concentrale/Dilute
Enractedsoluiion
+tri{ rira/ifi#
Filter/ +S.i{'E.d
Analysis
byGC/MS
/ fr"ian&f ie*,+&
*irl+
c o m D a n +! " , I
rirr,,: i;
r. lJ: ?.lria 1.:-!i
-j!,AlrI
3u!,0db'.ms,idcoidsdislolE
pslsl bdad h€rad cpod€nnorb3
i.,.-l:r311.!
|
|
t
l||tI
l
rF{-d,+E+
Test Report
f t 1 4 ( N o . ) , C E / 2 0 r 2 l 1 0 8 3 5E S ( D a r . ) , 2 o l 2 l l ] t / t t
F&{prse)
EI.SCHUI(OM
ELEI{TROSCHUTZ(OMA)NENTENB,{U
GVBIi
GE9ERBESTTASSE
87, D 98669 \,'EIT-SDoRF.GEf,Vl}IY
it+&fiAn
I
I
Il]tIltt][||||[|!
/ Analyticalflowchartof halogencontent
jtli{,l.F : gi',g* / Naneof thepersonwhomademe€surement:
RitaChen
jrl:i,A ll, : #,*e / Nameof thepersonin cbargeof measurement:
TroyChang
*+E &t&.'sl'I
Analysis
wE6perfomedby lC
.Iir
Th s ddfuh.il
s '$u€d bl ft
np61s) rssbd fu bn cpod €nnor b
i.'.iiri:llr
it
Li
ii'!r]-l
i -1"j! :
pa
c om
3 l b j e d b ] e m s a i d c o i d l o n s f o r E A t a ^ l o n 6 d d n l o f t ] m l a t o n d s b l t y
.;.: r.r- i.1-]ii1
r,r+ s6iorre
rD r+ s6 Lo?lrrenr
wwslon
ilts,#+
TestReport
it4(No. ) : cE/2012l10835 AS(Dare) : 201210r/tr
F*.(pase) : 9 of lo
E-SCHUKOM
EI-E(TROSCHUTZKO]\IIONENTEN&{U
GMBH
GEFERBESTRASSE
87, D-98669 VEIISDORF, CERMA]\ry
tI|fll|t][taf,
*Ji+n+fin€n /
Analyticalflow chartofSoxhtetextraction(LC/MS)procedure
r
r
i A/-F : ij!9*y / Nameofthe personwhomademeesuementRcmanWong
t4j:{, q i,\ : tF'.*4 / Nameof the personin chargeof measurement:
TroyChang
( rd8,{ a : Afi.+n*.n/Afi.+rt(*)
, **.:4i{bA4,
Test ltems: PFOS/PFOA. Benzotriazole)
*{*
cmpanyr:i r , tr 'ri_ll i ,r'"'ll:l ill+
r. r i rtirril: .
/ Datia
p3G)r8sbd
rh s rsd,epon
€inore
-. '.- it!,1 .
pdisb ,9 a b b cr ed and ih s dotum
/
l
trl'd,#+
TestReport
fi6(N". ) , c-E/2072/10a35
Es(Date) : 2tr2/ar/r1
E*@aEe) : r0 of t0
ELSCHTJKOM
ELENROSCHU'\ZKOMPONENTENBAU
GMBH
GEISRBESTR.ASSE
8?, D.98669 WII-SDOTF,GERVA}Y
trlt[tl
+ ffifi tr'6*t*i
' Fl* ftfrfl*lt,rlz{tsi
(The tested sanple / part is narked bt an arror if
ir's
1083s
10835
** lE+344.(E"d of Report) ++
i:. j:r.i | ,.tll
itt: I
c d h p , i in r . i ' , r , " r i l ' i , ,
rhsdoarudE 3s!sdbyhe.omp,^yeqedb G6erydcodromor s
+ *ri.*irr !r. i r,.
l6en,a r,p.
'
..
. !,r:L!.
${i'
t
shorn on rhe photo.)
fl|||trr
Test Report
Applicant:
Number : TWNC00233543S1
Littelfuse Philippines Inc.
LIMA Technology Center, Lipa City,
Malvar, Batangas
Date
: Dec 02, 2011
This is to supersede
report NO. TWNC00233543
dated Nov 25, 2011
Sample Description:
One (1) group of submitted samples said to be :
Part Description
: Yarn
Part Number
: 648112-001
Date Sample Received
: Nov 21, 2011
Date Test Started
: Nov 22, 2011
Test Conducted :
As requested by the applicant, for details please refer to attached pages.
Authorized By:
On Behalf Of Intertek Testing Services
Taiwan Limited
K. Y. Liang
Director
This report shall not be reproduced
except in full, without the written
approval of the laboratory.
Page 1 of 6
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00233543S1
Test Conducted
(Ⅰ) Test Result Summary :
Test Item
Result (ppm)
White Yarn
Heavy Metal
Cadmium (Cd) content
Lead (Pb) content
Mercury (Hg) content
Chromium VI (Cr6+) content
Polybrominated Biphenyls (PBBs)
Monobrominated Biphenyls (MonoBB)
Dibrominated Biphenyls (DiBB)
Tribrominated Biphenyls (TriBB)
Tetrabrominated Biphenyls (TetraBB)
Pentabrominated Biphenyls (PentaBB)
Hexabrominated Biphenyls (HexaBB)
Heptabrominated Biphenyls (HeptaBB)
Octabrominated Biphenyls (OctaBB)
Nonabrominated Biphenyls (NonaBB)
Decabrominated Biphenyl (DecaBB)
Polybrominated Diphenyl Ethers (PBDEs)
Monobrominated Diphenyl Ethers (MonoBDE)
Dibrominated Diphenyl Ethers (DiBDE)
Tribrominated Diphenyl Ethers (TriBDE)
Tetrabrominated Diphenyl Ethers (TetraBDE)
Pentabrominated Diphenyl Ethers (PentaBDE)
Hexabrominated Diphenyl Ethers (HexaBDE)
Heptabrominated Diphenyl Ethers (HeptaBDE)
Octabrominated Diphenyl Ethers (OctaBDE)
Nonabrominated Diphenyl Ethers (NonaBDE)
Decabrominated Diphenyl Ether (DecaBDE)
Halogen Content
Fluorine (F)
Chlorine (Cl)
Bromine (Br)
Iodine (I)
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
571
ND
ND
Remarks: ppm = Parts per million based on weight of tested sample = mg/kg
ND = Not detected
Responsibility of Chemist : Irene Chiou / Kevin Liu / Cathy Chen
Date Sample Received
Test Period
: Nov 21, 2011
: Nov 22, 2011 To Nov 25, 2011
Page 2 of 6
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00233543S1
Test Conducted
(Ⅱ) RoHS Requirement:
Restricted Substances
Cadmium (Cd) Content
Lead (Pb) Content
Mercury (Hg) Content
Chromium VI (Cr6+) Content
Polybrominated Biphenyls (PBBs)
Polybrominated Diphenyl Ehters (PBDEs)
Limits
0.01% (100ppm)
0.1% (1000ppm)
0.1% (1000ppm)
0.1% (1000ppm)
0.1% (1000ppm)
0.1% (1000ppm)
The above limits were quoted from 2002/95/EC and amendment 2005/618/EC for
homogeneous material.
(Ⅲ) Test Method:
Test Item
Cadmium (Cd)
content
Lead (Pb) content
Mercury (Hg)
content
Chromium VI (Cr6+)
content
Polybrominated
Biphenyls (PBBs)
Polybrominated
Diphenyl Ethers
(PBDEs)
Halogen Content
Test Method
With reference to IEC 62321 edition
1.0:2008 in clause 8/9/10, by
microwave digestion until the tested
samples are totally dissolved and
determined by ICP-OES.
With reference to IEC 62321 edition
1.0:2008 in clause 8/9/10, by
microwave digestion until the tested
samples are totally dissolved and
determined by ICP-OES.
With reference to IEC 62321 edition
1.0:2008 in clause 7, by microwave
digestion until the tested samples are
totally dissolved and determined by
ICP-OES.
With reference to IEC 62321 edition
1.0:2008 in annex C, by alkaline
digestion and determined by UV-Vis
spectrophotometer.
With reference to IEC 62321 edition
1.0:2008 in annex A, by solvent
extraction and determined by GC-MSD
and further HPLC confirmation when
necessary.
With reference to IEC 62321 edition
1.0:2008 in annex A, by solvent
extraction and determined by GC-MSD
and further HPLC confirmation when
necessary.
With reference to EN 14582:2007 by
calorimetric bomb with oxygen and
determined by ion chromatography
Reporting Limit
2 ppm
2 ppm
2 ppm
1 ppm
5 ppm
5 ppm
50 ppm
Remark: Reporting limit = Quantitation limit of analyte in sample
Page 3 of 6
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00233543S1
Test Conducted
(Ⅳ) Measurement Flowchart:
Test for Cd/Pb/Hg/Chromium (VI)/PBBS/PBDES Contents
Reference Standard: IEC 62321 edition 1.0:2008
Sample preparation
For non-metal part
For metal part
Take sample and immerse into Aqua Regia, start to strip plating layer
Stop the stripping procedure upon color change completely
Take the Aqua solution as plating component and stripped body as substrate component
Cd/Pb/Hg
Cr
Confirm the tested
samples are
totally dissolved
Make up with
deionized water
PBBs/PBDEs
Polymers /
electronics
Metal
For different
material, digest
the sample with
*1
appropriate acid
6+
Weigh sample and
add organic solvent
By spot test
Negative
Get 50cm2 sample
By boiling water
extraction
*2
Weigh sample
and add
alkaline
solution
By Soxhlet
extraction or
Solvent extraction
Definite temp.
extraction
Cool and filter
the extract
Analyzed by ICP-OES
Concentrate the
extract and make up
with organic
solvent
Analyzed by GC-MSD
Make up with deionized
water and add diphenylcarbazide solution
Analyzed by UV-VIS
Remarks:
*1: List of Appropriate Acid:
Material
Polymers
Metals
Electronics
Acid Added for Digestion
HNO3,HCl,HF,H2O2,H3BO3
HNO3,HCl,HF
HNO3,HCl,H2O2,HBF4
*2: If the result of spot test is positive, Chromium VI would be determined as detected.
Page 4 of 6
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00233543S1
Test Conducted
(Ⅳ) Measurement Flowchart:
Test for Halogen Content
Reference Standard:EN 14582
Sampling/grinding or
cutting
Add absorbent in a
combustion flask &
place weighed sample in
equipment
Fill oxygen into
calorimetric bomb
Ignite then leave the
flask at room
temperature
Transfer the absorbent
into a volumetric flask
Make up with deionized
water
Analyzed by ion
chromatography
End of Report
Page 5 of 6
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00233543S1
Test Conducted
Photo
Page 6 of 6
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401