LC75843UGA Application Note, Design method of the LCD system using static 1/4-duty LCD panel

LC75843UGA
Application Note
Design method of the LCD
system using 1/4-duty
LCD panel
http://onsemi.com
Overview
This application note explains the design method of the LCD (Liquid Crystal Display) system using LCD driver IC
(LC75843UGA). The LC75843UGA is the 1/1 to 1/4 duty general-purpose LCD driver that can be used in applications
such as automotive display by control with the controller.
In addition, this IC is able to drive up to 100 segments directly, and can also control up to four general-purpose
output ports. Moreover, it has a built-in 3ch PWM (Pulse Width Modulation) function for brightness adjustment of LED
(Light Emitting Diode). Furthermore, because of built-in the oscillator circuit, it is possible to reduce external resister
and external capacitor for oscillation.
 CCB is ON Semiconductor® ’s original format. All addresses are managed by ON Semiconductor® for this format.
 CCB is a registered trademark of Semiconductor Components Industries, LLC.
© Semiconductor Components Industries, LLC, 2014
April, 2014 - Rev.0
1
LC75843UGA Application Note
LCD System Configuration Example
This application note explains various function explanations and setting method example of serial control data in the
LCD system configuration using LCD driver IC (LC75843UGA) as shown below.
VOUP
(Pull-up power supply for LED)
LCD Driver IC
(LC75843UGA)
+5.0 [V]
S1/P1
(Button indicator A)
S2/P2
(Button indicator B)
S3/P3
(Button indicator C)
VDD
VSS
OSCI
S4/P4
(Backlight)
20
S5 to S24
LCD
Controller
/INH
3
(CCB interface)
CE
CL
DI
S28
(open)
S25/COM4
S26/COM3
S27/COM2
LCD Panel
(4com x 20seg = 80 segments)
COM1
Figure 1. LCD system configuration using LCD driver IC (LC75843UGA)
< Operation specifications of the LCD system >
LCD driver IC (LC75843UGA) specifications
Support for static (1/1-duty) or 1/2-duty or 1/3-duty or 1/4-duty
drive. (Capable of driving the LCD up to 100 segments directly)
Built-in LCD drive bias voltage stabilization circuit.
Support for up to four general-purpose output ports
Support for the PWM output function of a maximum of 3ch.
Support for clock output function of 1ch.
Incorporation of an oscillator circuit (Incorporation of resistor and
capacitor for an oscillation), and setting of the “Internal oscillator
operating mode” or “External clock input operating mode” is
possible by serial control data.
Serial control data input supports CCB* format communication
with the system controller. (Support 3.3V and 5.0V operation)
Adjustment of the frame frequency of the LCD drive waveform is
possible by serial control data.
Adjustment of the frame frequency of the PWM drive waveform is
possible by serial control data.
Setting of the power saving mode or the all segments turn off
mode is possible by serial control data.
The /INH pin allows the display to be forced off state.
LCD system specifications of Figure 1
The LCD panel to use has 20-segments and 4-commons.
Total display segments are 80-segments.
Therefore, LCD drive duty ratio is 1/4-duty.
1/3-bias.
The four general-purpose output ports are used.
Control of the LED by PWM function.
Unused.
Internal oscillator operating mode is used.
Used. (Controlled by LCD controller)
Frame frequency is adjusted, but frequency value is
undecided.
PWM is controlled, but frequency value is undecided.
Used. (Controlled by LCD controller)
Used. (Controlled by LCD controller)
http://onsemi.com
2
LC75843UGA Application Note
Pin Assignment
DI
CL
CE
/INH
OSCI
VSS
VDD
S28
COM1
COM2/S27
COM3/S26
COM4/S25
S24
S23
S22
S21
S20
S19
The following figure shows the pin assignment of LCD driver IC (LC75843UGA).
36
19
LC75843UGA
(TSSOP36)
(Top view)
1
S1/P1
S2/P2
S3/P3
S4/P4
S5
S6
S7
S8
S9
S10
S11
S12
S13
S14
S15
S16
S17
S18
18
Figure 2. Pin Assignment of LCD driver IC (LC75843UGA)
Table 1. Pin function of LCD driver IC (LC75843UGA)
Pin name
S1/P1
S2/P2
S3/P3
S4/P4
S5 to S24
S28
COM1
COM2/S27
COM3/S26
COM4/S25
OSCI
CE
CL
DI
/INH
VDD
VSS
Pin function
General-purpose port output pin.
The S1/P1 pin can be used as a segment drive pin by control data (P0 to P2).
General-purpose port output pin.
The S2/P2 pin can be used as a segment drive pin by control data (P0 to P2).
General-purpose port output pin.
The S3/P3 pin can be used as a segment drive pin by control data (P0 to P2).
General-purpose port output pin.
The S4/P4 pin can be used as a segment drive pin by control data (P0 to P2).
Segment drive output pins.
Segment drive output pin.
When “S28 output off mode (DN=0)”, S28 is VSS level output.
When “S28 output on mode (DN=1)”, S28 is segment output.
Common drive output pin.
Common drive or segment drive output pin.
The COM2/S27 pin can be used as a segment drive pin by control data (DT0, DT1).
Common drive or segment drive output pin.
The COM3/S26 pin can be used as a segment drive pin by control data (DT0, DT1).
Common drive or segment drive output pin.
The COM4/S25 pin can be used as a segment drive pin by control data (DT0, DT1).
External clock input pin.
When “Internal oscillator operating mode (OC=0)”, make sure to connect OSCI to GND.
When “External clock input mode (OC=1)”, OSCI is used to input the external clock.
Serial data transfer chip enable input pin.
Serial data transfer synchronization clock input pin.
Serial data transfer data input pin.
Display off control input pin.
/INH=High (VDD) : Display ON
/INH=Low (VSS) : Display forced off
General-purpose output port pins (S1/P1 to S4/P4) are VSS level.
Segment output pins (S5 to S24, and S28) are VSS level.
Common output pins (COM1, COM2/S27, COM3/S26 and COM4/S25) are VSS level.
The internal oscillator circuit is stopped.
External clock input is inhibited.
The reception of serial control data is possible. (Registers are updated)
Logic power supply pin for LCD driver IC. A power supply voltage of +4.5 [V] to +6.3 [V].
Ground pin. Must be connected all each board to the ground.
http://onsemi.com
3
LC75843UGA Application Note
Serial Control Data Transfer Explanation
(1) Basic Timing
The LC75843UGA has several internal registers. These internal registers are written by CCB interface (Serial
interface). Structure of transfer bits consists of CCB address and instruction data. First eight bits are CCB address
(44h). The bit number of instruction data is different depending on an instruction. The serial control data is taken by
the positive edge of the CL signal, which is latched by the negative edge of the CE signal. When the number of data
in CE=VDD period is different from the defined number (112-bits and 48-bits), IC does not execute the instruction
and holds the old state. Even when CL signal stops at high level, the CCB interface can be received. However, serial
Control Data transfer timing (transfer form) is different. Therefore, when designing equipment, refer to the “Delivery
specification for the LC75843UGA”.
CE input
CL input
DI input
Address
Display data
Control data
8 bits
Direction data (=0,1)
Instruction data (112 bits)
CE input
CL input
DI input
Address
Control data
Direction data (=1,0)
8 bits
Instruction data (48 bits)
Figure 3. Basic timing when CL signal is stopped at the Low Level
Since the IC internal data is undefined when power supply is first applied, applications should set the /INH pin=Low
(VSS) at the same time as power supply is applied to turn off the display (The S1/P1 to S4/P4, S5 to S24, COM4/S25,
COM3/S26, COM2/S27, COM1 and S28 pins are outputted at the VSS level), and during this period send serial
control data from the controller. The controller should then set the /INH pin=High (VDD) after the data transfer has
completed. This procedure prevents meaningless display at power supply on.
t1 > 1 [ms]
t2 > 0 [ms]
VDD
/INH input
tc > 10 [us]
Display OFF
Display ON
Display OFF
CE input
CCB
interface
CL input
DI input
DD=0,1 DD=1,0
Internal data
LCD display state
(Segments, Commons)
General-purpose
output ports state
(S1/P1 to S4/P4)
Undefined
Defined
Undefined
Display forced off (VSS level)
Segment ON is possible
Display forced off (VSS level)
Forced off (VSS level)
ON/OFF control is possible
Forced off (VSS level)
Figure 4. Basic timing of serial control data transfer
http://onsemi.com
4
LC75843UGA Application Note
(2) Allowable Operating Ranges of the Serial Control Data Transfer
The following figure shows the specifications of the allowable operating ranges when CL signal is stopped at the low
level.
VIH1
50%
VIL1
CE
tclL
tclH
VIH1
50%
VIL1
CL
tf
tcp
tr
tcs
tch
VIH1
50%
VIL1
DI
tds
tdh
Figure 5. Allowable operating ranges of serial control data transfer
Table 2. Allowable operating ranges
Parameter
Symbol
Conditions
Min.
Typ.
Max.
Unit
6.3
V
0.4 VDD
6.3
V
0
0.2 VDD
V
3.125
MHz
Power Supply Voltage
VDD
VDD
Input High Level Voltage
VIH1
CE, CL, DI, /INH
Input Low Level Voltage
VIL1
CE, CL, DI, /INH
Serial Data Transfer
Synchronization Clock Frequency
fcl
CL, 1/(tclL+tclH)
Data Setup Time
tds
CL, DI
160
ns
Data Hold Time
tdh
CL, DI
160
ns
CE Wait Time
tcp
CE, CL
160
ns
CE Setup Time
tcs
CE, CL
160
ns
CE Hold Time
tch
CE, CL
160
ns
High Level Clock Pulse Width
tclH
CL
160
ns
Low Level Clock Pulse Width
tclL
CL
160
ns
Rise Time
tr
CE, CL, DI
Fall Time
tf
CE, CL, DI
/INH Switching Time
tc
/INH, CE
4.5
10
160
ns
160
ns
us
These specifications show an example, and, we have a case to change these specifications without a notice for
improvement. Therefore, it is not guaranteed for design as the mass production equipment. When designing
equipment, refer to the “Delivery specification for the LC75843UGA”.
Functional operation above the stresses listed in the Recommended Operating Ranges is not implied. Extended exposure to stresses beyond the Recommended
Operating Ranges limits may affect device reliability.
http://onsemi.com
5
LC75843UGA Application Note
(3) Allotment of Serial Control Data
The following figure shows the serial control data transfer form when the “1/4-duty drive mode” and CL signal is
stopped at the low level.
CE
CL
DI
0
0
1
0
0
0
1
0
D1
D2
D3
D91 D92 D93 D94 D95 D96 D97 D98 D99 D100
0
0
0
0
0
0
0
0 DT0 DT1 0
1
B0 B1 B2 B3 A0 A1 A2 A3
CCB address
(8 bits)
Display data
(100 bits)
Control data
(10 bits)
Direction data
(2 bits)
CE
CL
DI
0
0
1
0
0
0
1
0
W10 W11 W12 W13 W14 W15 W20 W21 W22 W23 W24 W25 W30 W31 W32 W33 W34 W35
0
0
0
0
B0 B1 B2 B3 A0 A1 A2 A3
CCB address
(8 bits)
Control data
(18 bits)
Fixed data
(4 bits)
PF0 PF1 PF2 PF3 PS10 PS11 PS20 PS21 PS30 PS31 PS40 PS41 P0
P1
P2 FC0 FC1 FC2 FC3 DN EXF OC SC BU
Control data
(24 bits)
B0 to B3, A0 to A3
: CCB address. (=44h)
D1 to D100
DT0, DT1
W10 to W15
W20 to W25
W30 to W35
PF0 to PF3
PS10, PS11
PS20, PS21
PS30, PS31
PS40, PS41
P0 to P2
FC0 to FC3
DN
EXF
OC
SC
BU
: Display data setting registers.
: LCD drive type (Duty ratio, Bias ratio) setting registers.
: PWM duty setting registers of the PWM output function (ch1).
: PWM duty setting registers of the PWM output function (ch2).
: PWM duty setting registers of the PWM output function (ch3).
: PWM output waveform frame frequency setting registers.
: General-purpose output port (S1/P1) function setting registers.
: General-purpose output port (S2/P2) function setting registers.
: General-purpose output port (S3/P3) function setting registers.
: General-purpose output port (S4/P4) function setting registers.
: S1/P1 to S4/P4 output pins function setting registers.
: LCD drive waveform frame frequency setting registers.
: S28 pin function setting register.
: External clock operating frequency setting register. (When OC=1, EXF is valid.)
: Fundamental clock operating mode setting register.
: All segments turn off mode setting register.
: Power saving mode setting register.
http://onsemi.com
6
1
0
Direction data
(2 bits)
LC75843UGA Application Note
Explanation of the LCD drive control
LCD Driver IC
(LC75843UGA)
S1/P1
(LED is controlled by general-purpose output port)
S2/P2
(LED is controlled by general-purpose output port)
S3/P3
(LED is controlled by general-purpose output port)
S4/P4
(LED is controlled by general-purpose output port)
S5 to S24
S28
20
(open)
S25/COM4
S26/COM3
S27/COM2
COM1
LCD Panel
(4com x 20seg = 80 segments)
Figure 6. Peripheral circuits configuration example of the LCD driver outputs
(1) LCD Drive Waveform
It is explanation about the drive type of the 1/4-duty and 1/3-bias. The common outputs (COM1, COM2/S27,
COM3/S26 and COM2/S25) repeat VDD level, VSS level, 1/3 VDD level and 2/3 VDD level in turn. On the other
hand, the segment outputs (S5 to S24, and S28) repeat VSS level, VDD level, 2/3 VDD level and 1/3 VDD level by a
state of display ON/OFF (Display data setting register is 1/0). When the LCD segment is ON (It interrupt light), the
potential difference of segment output and common output becomes VDD level. When the LCD segment is OFF (It
penetrate light), the potential difference of segment output and common output becomes lower than 1/3 VDD level.
This drive method assigns a fourth of a frame to control of ON/OFF of one segment. In addition, this drive method
uses the 2/3 VDD level and 1/3 VDD level divided in three between VDD and VSS. Thus, this drive method is called
the “1/4-duty and 1/3-bias drive”. When set the “1/4-duty drive mode”, the following figure shows the LCD drive
waveform.
VDD
/INH input
Display forced off
Display on
VSS
VDD
2/3 VDD
1/3 VDD
VSS
COM1 output
VSS
S27/COM2 output
VDD
2/3 VDD
1/3 VDD
VSS
VSS
VDD
2/3 VDD
1/3 VDD
VSS
S26/COM3 output
VSS
S25/COM4 output
LCD driver output when all LCD segments
corresponding to COM1 to COM4 are off.
(When display data were set to “0, 0, 0, 0”)
LCD driver output when only LCD segments
corresponding to COM1 are on.
(When display data were set to “1, 0, 0, 0”)
LCD driver output when only LCD segments
corresponding to COM2 are on.
(When display data were set to “0, 1, 0, 0”)
LCD driver output when only LCD segments
corresponding to COM3 are on.
(When display data were set to “0, 0, 1, 0”)
LCD driver output when only LCD segments
corresponding to COM4 are on.
(When display data were set to “0, 0, 0, 1”)
LCD driver output when LCD segments
corresponding to COM1 and COM2 are on.
(When display data were set to “1, 1, 0, 0”)
LCD driver output when LCD segments
corresponding to COM1 to COM3 are on.
(When display data were set to “1, 1, 1, 0”)
LCD driver output when all LCD segments
corresponding to COM1 to COM4 are on.
(When display data were set to “1, 1, 1, 1”)
VSS
VDD
2/3 VDD
1/3 VDD
VSS
VSS
VDD
2/3 VDD
1/3 VDD
VSS
VSS
VDD
2/3 VDD
1/3 VDD
VSS
VSS
VDD
2/3 VDD
1/3 VDD
VSS
VSS
VDD
2/3 VDD
1/3 VDD
VSS
VSS
VDD
2/3 VDD
1/3 VDD
VSS
VSS
VDD
2/3 VDD
1/3 VDD
VSS
VSS
VDD
2/3 VDD
1/3 VDD
VSS
VSS
VDD
2/3 VDD
1/3 VDD
VSS
Frame frequency
fo [Hz]
Figure 7. LCD driver output waveform
http://onsemi.com
7
LC75843UGA Application Note
(2) LCD Drive Type Setting (DT0, DT1)
The registers of the DT0 and DT1 can set the LCD drive type from 1/1-duty to 1/4-duty. The LCD system
configuration example is LCD panel of the 1/4-duty drive used. Therefore, this system sets DT0=0 and DT1=0.
DT0
DT1
LCD drive type
0
1
0
1
0
0
1
1
1/4-duty and 1/3-bias drive type
1/3-duty and 1/3-bias drive type
1/2-duty and 1/2-bias drive type
Static (1/1-duty) drive type
COM1
COM1
COM1
COM1
COM1
Output pins state
COM2/S27 COM3/S26 COM4/S25
COM2
COM2
COM2
S27
COM3
COM3
S26
S26
COM4
S25
S25
S25
(3) S28 Pin Function Setting (DN)
The DN register can set the “Segment output of the S28 output pin” or “VSS level output of the S28 output pin”.
The LCD system configuration example does not use S28 output pin. Therefore, this system sets DN=0.
DN
S28 output pin state
0
1
VSS level output
S28 segment output
(4) Display Data Setting (D1 to D100)
The registers from D1 to D100 set the LCD segment ON/OFF, or these registers set the general-purpose output
port (P1 to P4) of high level output or low level output. The LCD system configuration example is the “1/4-duty drive
mode”, and LCD segments from S5 to S24 used. Therefore, set the LCD display data from D17 to D96. In addition,
the pins from S1/P1 to S4/P4 use general-purpose output port function. Therefore, set the general-purpose output
ports (P1 to P4) of high level output or low level output by the LCD display data to D1, D5, D9 and D13. About the
control method of “Display data setting registers (D1 to D16)”, refer to paragraph (3) of “Explanation of the LED
Control by General-purpose Output Ports”.
When set the “1/4-duty drive mode”, the following table shows the relation between the “Display data setting
registers (D17 to D96)” and the segment outputs and the common outputs.
Output pin
COM1
S5
S6
S7
S8
S9
S10
S11
S12
S13
S14
S15
S16
S17
S18
S19
S20
S21
S22
S23
S24
D17
D21
D25
D29
D33
D37
D41
D45
D49
D53
D57
D61
D65
D69
D73
D77
D81
D85
D89
D93
COM2/S27 COM3/S26 COM4/S25
D18
D22
D26
D30
D34
D38
D42
D46
D50
D54
D58
D62
D66
D70
D74
D78
D82
D86
D90
D94
D19
D23
D27
D31
D35
D39
D43
D47
D51
D55
D59
D63
D67
D71
D75
D79
D83
D87
D91
D95
D20
D24
D28
D32
D36
D40
D44
D48
D52
D56
D60
D64
D68
D72
D76
D80
D84
D88
D92
D96
S28
D97
D98
D99
D100
http://onsemi.com
8
Notes
Thes display data are unused, and D97 to D100 sets the
all “0”.
LC75843UGA Application Note
For example, the following table shows the relation between the “Display data setting register” and S5 output pin
state.
D17
Display data
D18
D19
S5 output pin state
D20
0
0
0
0
1
0
0
0
0
1
0
0
1
1
0
0
0
0
1
0
1
0
1
0
0
1
1
0
1
1
1
0
0
0
0
1
1
0
0
1
0
1
0
1
1
1
0
1
0
0
1
1
1
0
1
1
0
1
1
1
1
1
1
1
All LCD segments corresponding to COM1 to COM4 are off.
LCD segments corresponding to COM1 is on and
LCD segments corresponding to COM2 to COM4 are off.
LCD segments corresponding to COM2 is on and
LCD segments corresponding to COM1, COM3, and COM4 are off.
LCD segments corresponding to COM1 and COM2 are on and
LCD segments corresponding to COM3 and COM4 are off.
LCD segments corresponding to COM3 is on and
LCD segments corresponding to COM1, COM2, and COM4 are off.
LCD segments corresponding to COM1 and COM3 are on and
LCD segments corresponding to COM2 and COM4 are off.
LCD segments corresponding to COM2 and COM3 are on and
LCD segments corresponding to COM1 and COM4 are off.
LCD segments corresponding to COM1 to COM3 are on and
LCD segments corresponding to COM4 is off.
LCD segments corresponding to COM4 is on and
LCD segments corresponding to COM1 to COM3 are off.
LCD segments corresponding to COM1 and COM4 are on and
LCD segments corresponding to COM2 and COM3 are off.
LCD segments corresponding to COM2 and COM4 are on and
LCD segments corresponding to COM1 and COM3 are off.
LCD segments corresponding to COM1, COM2, and COM4 are on and
LCD segments corresponding to COM3 is off.
LCD segments corresponding to COM3 and COM4 are on and
LCD segments corresponding to COM1 and COM2 are off.
LCD segments corresponding to COM1, COM3. and COM4 are on and
LCD segments corresponding to COM2 is off.
LCD segments corresponding to COM2 to COM4 are on and
LCD segments corresponding to COM1 is off.
All LCD segments corresponding to COM1 to COM4 are on.
Explanation of the LED Control by General-purpose Output Ports
VOUP
(Pull-up power supply for LED)
LCD Driver IC
(LC75843UGA)
S1/P1
(Button indicator A)
S2/P2
(Button indicator B)
S3/P3
(Button indicator C)
S4/P4
(Backlight)
Figure 8. Peripheral circuits configuration example of the general-purpose output ports
http://onsemi.com
9
LC75843UGA Application Note
(1) LED Control Waveform
The LC75843UGA has up to four general-purpose output ports. In addition, the PWM output function has up to 3ch
and can perform brightness adjustment of the LED individually for each channel. The brightness of the LED has a
method to adjust a forward current of LED flowing at the time of ON, or there is pulse width modulation (PWM)
control to adjust the apparent brightness by repeating ON and OFF at high speed. The LED looks bright if the ON
time per unit time by PWM control is long. In addition, it looks dark if the ON time per unit time by PWM control is
short. When LED is always turn on (Brightness is 100%), the consumption electric current is maximum. When LED is
ON, the LED uses electricity, and when LED is OFF, the LED does not use electricity. Thus, it can set the low power
consumption by PWM control. When used the general-purpose output port, the following figure shows the LED
control waveform.
/INH input
S1/P1 to S4/P4 outputs
when general-purpose output portwas set to low
S1/P1 to S4/P4 outputs
when general-purpose output port was set to high
VDD
LED off
LED on
VSS
VDD
LED off
LED off (0% duty)
LED off
LED on (100% duty)
VSS
VDD
VSS
LED on
S1/P1 to S4/P4 outputs
when PWM duty was set to 1/64(1.56%)
VDD
LED off
VSS
LED on
S1/P1 to S4/P4 outputs
when PWM duty was set to 2/64(3.12%)
VDD
LED off
VSS
LED on
S1/P1 to S4/P4 outputs
when PWM duty was set to 3/64(4.69%)
LED off
VDD
S1/P1 to S4/P4 outputs
when PWM duty was set to 32/64(50.00%)
LED off
S1/P1 to S4/P4 outputs
when PWM duty was set to 62/64(96.87%)
LED off
LED on
S1/P1 to S4/P4 outputs
when PWM duty was set to 63/64(98.44%)
LED off
LED on
S1/P1 to S4/P4 outputs
when PWM duty was set to 64/64(100.00%)
LED off
LED on
VSS
VDD
LED on
VSS
VDD
VSS
VDD
VSS
VDD
VSS
Frame frequency
fp [Hz]
Figure 9. General-purpose port output waveform
(2) S1/P1 to S4/P4 Output Pins Function Setting (P0 to P2)
The registers from P0 to P2 can set the “Output pins from S1/P1 to S4/P4 of the segment output port” or “Output
pins from S1/P1 to S4/P4 of the general-purpose output port”. The LCD system configuration example controls LED
by general-purpose output port of the S1/P1 to S4/P4 output pins. Therefore, this system sets P0=1, P1=0 and P2=0.
P0
P1
P2
0
0
0
0
1
1
1
1
0
0
1
1
0
0
1
1
0
1
0
1
0
1
0
1
S1/P1
S1
P1
P1
P1
P1
S1
S1
S1
Output pin state
S2/P2
S3/P3
S2
S3
S2
S3
P2
S3
P2
P3
P2
P3
S2
S3
S2
S3
S2
S3
http://onsemi.com
10
S4/P4
S4
S4
S4
S4
P4
S4
S4
S4
S1 to S4 : Segment output ports
P1 to P4 : General-purpose output ports
LC75843UGA Application Note
(3) General-purpose Ports (P1 to P4) Function Setting (PS10,PS11,PS20,PS21,PS30,PS31,PS40 and PS41)
The registers from PS10 and PS11 can set the “General-purpose output function”, “Clock output function”, or “PWM
output function” of the general-purpose output port (P1). In addition, PS20, PS21, PS30, PS31, PS40 and PS41
registers can set the “General-purpose output function” or “PWM output function” of the general-purpose output ports
(P2 to P4). The general-purpose output function outputs general-purpose output ports (P1 to P4) of high level or low
level by “Display data setting registers (D1 to D16)”. The clock output function outputs internal oscillator clock (fosc)
or external clock input (fck) of the 1/2 frequency division or 1/8 frequency division. This function can set only generalpurpose output port (P1). Therefore, when stop the clock, the “Display data setting register (D1)” by general-purpose
output function sets the “0”, and general-purpose output port (P1) outputs low level. The PWM output function has up
to 3ch and can perform brightness adjustment of the LED individually for each channel. However, PWM duty setting
register (W10 to W15, W20 to W25, and W30 to W35) does not have a setting function of 0%-duty. Therefore when
you want to turn off the LED, the “Display data setting registers (D1 to D16)” by general-purpose output function set
the “0”, and general-purpose output ports (P1 to P4) output low level.
PS10
0
1
0
1
PS11
0
0
1
1
General-purpose output port (P1) function
General-purpose output function : High level or low level output
Clock output function : Outputs a clock of the fosc/2 frequency
Clock output function : Outputs a clock of fosc/8 frequency
PWM output function (ch1) : Controlled by PWM duty setting register from W10 to W15
PS20
0
1
0
1
PS21
0
0
1
1
General-purpose output port (P2) function
General-purpose output function : High level or low level output
PWM output function (ch1) : Controlled by PWM duty setting register from W10 to W15
PWM output function (ch2) : Controlled by PWM duty setting register from W20 to W25
PWM output function (ch3) : Controlled by PWM duty setting register from W30 to W35
PS30
0
1
0
1
PS31
0
0
1
1
General-purpose output port (P3) function
General-purpose output function : High level or low level output
PWM output function (ch1) : Controlled by PWM duty setting register from W10 to W15
PWM output function (ch2) : Controlled by PWM duty setting register from W20 to W25
PWM output function (ch3) : Controlled by PWM duty setting register from W30 to W35
PS40
0
1
0
1
PS41
0
0
1
1
General-purpose output port (P4) function
General-purpose output function : High level or low level output
PWM output function (ch1) : Controlled by PWM duty setting register from W10 to W15
PWM output function (ch2) : Controlled by PWM duty setting register from W20 to W25
PWM output function (ch3) : Controlled by PWM duty setting register from W30 to W35
The LCD system configuration example uses general-purpose output port function from S1/P1 to S4/P4. The
following table shows the relation between the “Display data setting registers (D1 to D16)” and general-purpose
output ports (P1 to P4) of high level or low level.
Display data
Controlled output pin
D1
S1/P1
D5
S2/P2
D9
S3/P3
D13
S4/P4
Notes
When PS10=0, PS11=0 and D1=0, S1/P1 is outputted at the low level.
When PS10=0, PS11=0 and D1=1, S1/P1 is outputted at the high level.
When “PS10, PS11” are not “0, 0”, D1 is invalid.
When PS20=0, PS21=0 and D5=0, S2/P2 is outputted at the low level.
When PS20=0, PS21=0 and D5=1, S2/P2 is outputted at the high level.
When “PS20, PS21” are not “0, 0”, D5 is invalid.
When PS30=0, PS31=0 and D9=0, S3/P3 is outputted at the low level.
When PS30=0, PS31=0 and D9=1, S3/P3 is outputted at the high level.
When “PS30, PS31” are not “0, 0”, D9 is invalid.
When PS40=0, PS41=0 and D13=0, S4/P4 is outputted at the low level.
When PS40=0, PS41=0 and D13=1, S4/P4 is outputted at the high level.
When “PS40, PS41” are not “0, 0”, D13 is invalid.
http://onsemi.com
11
LC75843UGA Application Note
When control the LED in the system configuration example of the Figure 8, a register setting example is shown
below.
(Case 1) When all LED were set to OFF.
General-purpose output port
(P1) control
OFF
PS10
PS11
D1
0
0
0
General-purpose output port
(P2) control
OFF
PS20
PS21
D5
0
0
0
General-purpose output port
(P3) control
OFF
PS30
PS31
D9
0
0
0
General-purpose output port
(P4) control
OFF
PS40
PS41
D13
0
0
0
General-purpose output port
(P3) control
OFF
PS30
PS31
D9
0
0
0
General-purpose output port
(P4) control
ON (W30 to W35=1,1,1,1,1,0)
PS40
PS41
D13
1
1
0
(Case 2) When backlight-LED was set to ON (Brightness is 50%).
General-purpose output port
(P1) control
OFF
PS10
PS11
D1
0
0
0
General-purpose output port
(P2) control
OFF
PS20
PS21
D5
0
0
0
(Case 3) When backlight-LED was set to ON (Brightness is 50%) and button indicator A-LED was set to ON (Brightness is 50%).
General-purpose output port
(P1) control
ON (W10 to W15=1,1,1,1,1,0)
PS10
PS11
D1
1
1
0
General-purpose output port
(P2) control
OFF
PS20
PS21
D5
0
0
0
General-purpose output port
(P3) control
OFF
PS30
PS31
D9
0
0
0
General-purpose output port
(P4) control
ON (W30 to W35=1,1,1,1,1,0)
PS40
PS41
D13
1
1
0
(Case 4) When backlight-LED was set to ON (Brightness is 50%) and button indicator B-LED was set to ON (Brightness is 50%).
General-purpose output port
(P1) control
OFF
PS10
PS11
D1
0
0
0
General-purpose output port
(P2) control
ON (W10 to W15=1,1,1,1,1,0)
PS20
PS21
D5
1
0
0
General-purpose output port
(P3) control
OFF
PS30
PS31
D9
0
0
0
General-purpose output port
(P4) control
ON (W30 to W35=1,1,1,1,1,0)
PS40
PS41
D13
1
1
0
(Case 5) When backlight-LED was set to ON (Brightness is 50%) and button indicator A/B/C-LED were set to ON (Brightness is 50%).
General-purpose output port
General-purpose output port
General-purpose output port
General-purpose output port
(P1) control
(P2) control
(P3) control
(P4) control
ON (W10 to W15=1,1,1,1,1,0) ON (W10 to W15=1,1,1,1,1,0) ON (W20 to W25=1,1,1,1,1,0) ON (W30 to W35=1,1,1,1,1,0)
PS10
PS11
D1
PS20
PS21
D5
PS30
PS31
D9
PS40
PS41
D13
1
1
0
1
0
0
0
1
0
1
1
0
(Case 6) When button indicator C-LED was changed from 50% to 79.69%.
General-purpose output port
General-purpose output port
General-purpose output port
General-purpose output port
(P1) control
(P2) control
(P3) control
(P4) control
ON (W10 to W15=1,1,1,1,1,0) ON (W10 to W15=1,1,1,1,1,0) ON (W20 to W25=0,1,0,0,1,1) ON (W30 to W35=1,1,1,1,1,0)
PS10
PS11
D1
PS20
PS21
D5
PS30
PS31
D9
PS40
PS41
D13
1
1
0
1
0
0
0
1
0
1
1
0
(Case 7) When backlight-LED was set to OFF.
General-purpose output port
General-purpose output port
General-purpose output port
(P1) control
(P2) control
(P3) control
ON (W10 to W15=1,1,1,1,1,0) ON (W10 to W15=1,1,1,1,1,0) ON (W20 to W25=0,1,0,0,1,1)
PS10
PS11
D1
PS20
PS21
D5
PS30
PS31
D9
1
1
0
1
0
0
0
1
0
General-purpose output port
(P4) control
OFF
PS40
PS41
D13
0
0
0
(Case 8) When all LED were set to ON (Brightness is 100%).
General-purpose output port
General-purpose output port
General-purpose output port
General-purpose output port
(P1) control
(P2) control
(P3) control
(P4) control
ON (W10 to W15=1,1,1,1,1,1) ON (W10 to W15=1,1,1,1,1,1) ON (W20 to W25=1,1,1,1,1,1) ON (W30 to W35=1,1,1,1,1,1)
PS10
PS11
D1
PS20
PS21
D5
PS30
PS31
D9
PS40
PS41
D13
1
1
0
1
0
0
0
1
0
1
1
0
or
General-purpose output port
(P1) control
ON
PS10
PS11
D1
0
0
1
General-purpose output port
(P2) control
ON
PS20
PS21
D5
0
0
1
General-purpose output port
(P3) control
ON
PS30
PS31
D9
0
0
1
http://onsemi.com
12
General-purpose output port
(P4) control
ON
PS40
PS41
D13
0
0
1
LC75843UGA Application Note
(4) PWM Duty Setting (W10 to W15, W20 to W25, W30 to W35)
The registers from W10 to W15, from W20 to W25, and from W30 to W35 can set the pulse width of the PWM
output. The PWM duty setting has up to 3ch and can perform brightness adjustment of the LED individually for each
channel. However, the PWM duty setting register (W10 to W15, W20 to W25, and W30 to W35) does not have a
setting function of the 0%-duty. Therefore when you want to turn off the LED, the “Display data setting registers (D1
to D16)” by general-purpose output function set the “0”, and general-purpose output ports (P1 to P4) output low level.
T p = 1 / fp
S1/P1 to S4/P4
LED off
Tpl
Wx0 Wx1 Wx2 Wx3 Wx4 Wx5
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
0
1
1
0
0
1
1
0
0
1
1
0
0
1
1
0
0
1
1
0
0
1
1
0
0
1
1
0
0
1
1
0
0
0
0
1
1
1
1
0
0
0
0
1
1
1
1
0
0
0
0
1
1
1
1
0
0
0
0
1
1
1
1
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Tph
PWM output pulse width
(PWM duty)
1/64 (1.56%)
2/64 (3.12%)
3/64 (4.69%)
4/64 (6.25%)
5/64 (7.81%)
6/64 (9.38%)
7/64 (10.94%)
8/64 (12.50%)
9/64 (14.06%)
10/64 (15.62%)
11/64 (17.19%)
12/64 (18.75%)
13/64 (20.31%)
14/64 (21.87%)
15/64 (23.44%)
16/64 (25.00%)
17/64 (26.56%)
18/64 (28.12%)
19/64 (29.69%)
20/64 (31.25%)
21/64 (32.81%)
22/64 (34.37%)
23/64 (35.94%)
24/64 (37.50%)
25/64 (39.06%)
26/64 (40.62%)
27/64 (42.19%)
28/64 (43.75%)
29/64 (45.31%)
30/64 (46.87%)
31/64 (48.44%)
32/64 (50.00%)
LED
on
PWM duty = (Tph / (Tpl+Tph))
Wx0 Wx1 Wx2 Wx3 Wx4 Wx5
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
0
1
1
0
0
1
1
0
0
1
1
0
0
1
1
0
0
1
1
0
0
1
1
0
0
1
1
0
0
1
1
0
0
0
0
1
1
1
1
0
0
0
0
1
1
1
1
0
0
0
0
1
1
1
1
0
0
0
0
1
1
1
1
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
PWM output pulse width
(PWM duty)
33/64 (51.56%)
34/64 (53.12%)
35/64 (54.69%)
36/64 (56.25%)
37/64 (57.81%)
38/64 (59.37%)
39/64 (60.94%)
40/64 (62.50%)
41/64 (64.06%)
42/64 (65.62%)
43/64 (67.19%)
44/64 (68.75%)
45/64 (70.31%)
46/64 (71.87%)
47/64 (73.44%)
48/64 (75.00%)
49/64 (76.56%)
50/64 (78.12%)
51/64 (79.69%)
52/64 (81.25%)
53/64 (82.81%)
54/64 (84.37%)
55/64 (85.94%)
56/64 (87.50%)
57/64 (89.06%)
58/64 (90.62%)
59/64 (92.19%)
60/64 (93.75%)
61/64 (95.31%)
62/64 (96.87%)
63/64 (98.44%)
64/64 (100.00%)
x : 1 to 3
Explanation of the Instruction Data
(1) Fundamental Clock Operating Mode Setting (OC, EXF)
LCD Driver IC
(LC75843UGA)
Internal oscillator clock frequency
fosc [kHz]
OSCI
Internal oscillator circuit clock
Figure 10. Peripheral circuits configuration example of the external clock input pin
http://onsemi.com
13
LC75843UGA Application Note
The OC register can set the “Internal oscillator operating mode” or “External clock input operating mode”.
Furthermore, when OC register sets the “External clock input operating mode (OC=1)”, the EXF register can set the
division ratio. The EXF register can set the division ratio a clock to input from OSCI pin becomes 300 [kHz](Typ.) and
38 [kHz](Typ.). However, when set the “External clock 38kHz input mode (OC=1 and EXF=1)”, please be careful
because PWM output function is invalidity. The LCD system configuration example sets OC=0 and EXF=0 to use the
“Internal oscillator operating mode”.
OC
EXF
Fundamental clock operating mode
OSCI input pin state
0
1
1
0/1
0
1
Internal oscillator operating mode
External clock 300kHz input mode
External clock 38kHz input mode
Connect to GND
Inputs a clock of 300 [kHz](Typ.)
Inputs a clock of 38 [kHz](Typ.)
The explanation mentioned above is used only to explain internal operation and how to IC, and the characteristic of
the products is uneven by a production variation and the terms of use of the IC (Power supply voltage, temperature,
etc.). Therefore, the customer should always evaluate and test devices mounted in the customer’s products or
equipment.
(2) LCD Drive Waveform Frame Frequency Setting (FC0 to FC3)
The registers from FC0 to FC3 can set the frame frequency (fo) of the common and segment output waveform. The
frame frequency (frame ratio) setting of the LCD drive waveform is different by “Fundamental clock operating mode
setting register (OC)” and “External clock operating frequency setting register (EXF)”.
Frame frequency
fo [Hz]
Internal oscillator clock frequency
fosc [kHz]
LCD drive waveform
Internal oscillator circuit clock
The LCD system configuration example sets OC=0 to use the “Internal oscillator operating mode”. When sets
OC=0, the following table shows the frame frequency of the LCD drive waveform.
FC0
FC1
FC2
FC3
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
0
0
0
0
1
1
1
1
0
0
0
0
1
1
1
1
0
0
1
1
0
0
1
1
0
0
1
1
0
0
1
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
Internal oscillator operating mode (OC=0)
LCD drive waveform frame frequency
fo [Hz]
LCD drive waveform frame ratio
(Internal oscillator clock frequency is
fosc=300 [kHz](typ.))
fosc / 6144
48.83
fosc / 5376
55.80
fosc / 4608
65.10
fosc / 3840
78.12
fosc / 3456
86.80
fosc / 3072
97.66
fosc / 2688
111.61
fosc / 2304
130.21
fosc / 2112
142.04
fosc / 1920
156.25
fosc / 1728
173.61
fosc / 1536
195.31
fosc / 1344
223.21
fosc / 1152
260.42
fosc / 960
312.50
fosc / 768
390.62
The explanation mentioned above is used only to explain internal operation and how to IC, and the characteristic of
the products is uneven by a production variation and the terms of use of the IC (Power supply voltage, temperature,
etc.). Therefore, the customer should always evaluate and test devices mounted in the customer’s products or
equipment.
http://onsemi.com
14
LC75843UGA Application Note
(3) PWM Output Waveform Frame Frequency Setting (PF0 to PF3)
The registers from PF0 to PF3 can set the PWM output frame frequency (fp) of the general-purpose output port.
When set the “External clock input operating mode setting (OC = 1)” and “External clock 38kHz input mode setting
(EXF=1)”, these registers are invalid.
Internal oscillator clock frequency
fosc [kHz]
Internal oscillator circuit clock
Frame frequency
fp [Hz]
PWM output waveform
The LCD system configuration example is “Internal oscillator operating mode” operated. Therefore, this system
sets OC=0. When sets OC=0, the following table shows the frame frequency (fp) of the PWM output waveform.
PF0
PF1
PF2
PF3
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
0
1
1
0
0
1
1
0
0
1
1
0
0
1
1
0
0
0
0
1
1
1
1
0
0
0
0
1
1
1
1
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
Internal oscillator operating mode (OC=0)
PWM output waveform frame frequency
fp [Hz]
PWM output waveform frame ratio
(Internal oscillator clock frequency is
fosc=300 [kHz](typ.))
fosc / 1536
195.31
fosc / 1408
213.07
fosc / 1280
234.37
fosc / 1152
260.42
fosc / 1024
292.97
fosc / 896
334.82
fosc / 768
390.62
fosc / 640
468.75
fosc / 512
585.94
fosc / 384
781.25
fosc / 256
1171.87
fosc / 896
334.82
fosc / 896
334.82
fosc / 896
334.82
fosc / 896
334.82
fosc / 896
334.82
The explanation mentioned above is used only to explain internal operation and how to IC, and the characteristic of
the products is uneven by a production variation and the terms of use of the IC (Power supply voltage, temperature,
etc.). Therefore, the customer should always evaluate and test devices mounted in the customer’s products or
equipment.
(4) All Segments Turn Off Mode Setting (SC)
The SC register can set the “Normal mode” or “All segments turn off mode”. The LC75843UGA can display forced
turn off by the /INH pin. When sets /INH pin=Low (VSS), segment outputs (S5 to S24, and S28), common outputs
(COM1, COM2/S27, COM3/S26, and COM4/S25) and general-purpose port outputs (S1/P1 to S4/P4) are outputted
at the all VSS level. In addition, it can display OFF (turn off the segments) by controllable SC register from the
software of the LCD controller. When sets SC=1, segment outputs (S5 to S24, and S28) are outputted at the all off
waveform.
/INH
pin
SC
register
Low (VSS)
0/1
High (VDD)
0
1
Segment outputs
(S5 to S24, and S28)
All segment outputs are VSS
level
Segments can output ON
waveform
All segment outputs are OFF
waveform
Output pin state
Common output
(COM1, COM2/S27,
COM3/S26, and COM4/S25)
All common outputs are VSS
level
Common outputs are scan
drive waveform
Common outputs are scan
drive waveform
http://onsemi.com
15
General-purpose port outputs
(S1/P1 to S4/P4)
All general-purpose port
outputs are VSS level
General-purpose outputs or
PWM waveform
General-purpose outputs or
PWM waveform
LC75843UGA Application Note
The LCD system configuration example is LCD panel of the 1/4-duty drive used. Therefore, when set “1/4-duty
drive mode (DT0=0 and DT1=0)”, the following figure shows the LCD drive waveform.
VDD
/INH input
Display on
Display forced off
VSS
VDD
2/3 VDD
1/3 VDD
VSS
COM1 output
VSS
S27/COM2 output
VDD
2/3 VDD
1/3 VDD
VSS
VSS
VDD
2/3 VDD
1/3 VDD
VSS
S26/COM3 output
VSS
S25/COM4 output
LCD driver output when all LCD segments
corresponding to COM1 to COM4 are off.
(When display data were set to “0, 0, 0, 0”)
LCD driver output when only LCD segments
corresponding to COM1 are on.
(When display data were set to “1, 0, 0, 0”)
LCD driver output when LCD segments
corresponding to COM1 and COM2 are on.
(When display data were set to “1, 1, 0, 0”)
LCD driver output when LCD segments
corresponding to COM2 and COM4 are on.
(When display data were set to “0, 1, 0, 1”)
LCD driver output when LCD segments
corresponding to COM1 to COM3 are on.
(When display data were set to “1, 1, 1, 0”)
LCD driver output when LCD segments
corresponding to COM1, COM3, and COM4 are on.
(When display data were set to “1, 0, 1, 1”)
LCD driver output when all LCD segments
corresponding to COM1 to COM4 are on.
(When display data were set to “1, 1, 1, 1”)
VSS
VDD
2/3 VDD
1/3 VDD
VSS
VSS
VDD
2/3 VDD
1/3 VDD
VSS
VSS
VDD
2/3 VDD
1/3 VDD
VSS
VSS
VDD
2/3 VDD
1/3 VDD
VSS
VSS
VDD
2/3 VDD
1/3 VDD
VSS
VSS
VDD
2/3 VDD
1/3 VDD
VSS
VSS
VDD
2/3 VDD
1/3 VDD
VSS
VSS
VDD
2/3 VDD
1/3 VDD
VSS
All segments turn off mode
SC=0
SC=1
Normal mode
SC=0
Figure 11. LCD driver output waveform when SC is set
(5) Power Saving Mode Setting (BU)
The BU register can set the “Normal mode” or “Power saving mode”. The LC75843UGA built-in the “Power saving
mode” as a low power consumption mode. When set the “Power saving mode”, the internal oscillator circuit is
stopped, and external clock input is inhibited and common / segment output pins are outputted at the VSS level.
However, the output pins from S1/P1 to S4/P4 can output of high level or low level as a general-purpose output
function by “Display data setting registers (D1 to D16)”. (PWM output function is invalid)
BU
Low power consumption mode
0
Normal mode
1
Power saving mode
Internal operating conditions
Normal mode
• When output pins from S1/P1 to S4/P4 set the general-purpose output
port, the output pins from S1/P1 to S4/P4 can use only a general-purpose
output function of high level or low level.
• Segment output pins (S5 to S24, and S28) are VSS level.
• Common output pins (COM1, COM2/S27, COM3/S26, and COM4/S25)
are VSS level.
• The internal oscillator circuit is stopped.
• External clock input is inhibited.
• The reception of serial control data is possible. (Registers are updated)
http://onsemi.com
16
LC75843UGA Application Note
Software Control Example of the LCD Controller
(1) Timing Chart From Power-on State to LCD Display ON
First, the following figure shows the timing waveform from power-on state to initial setting and LCD display ON in
the LCD system configuration example.
+5.0 [V]
VDD
t1 > 1 [ms]
/INH
tc > 10 [us]
High
Low
CE
CL
DI
Note 1
fo = 97.66 [Hz]
Scan drive waveform output
COM1
Display forced off (VSS level)
Scan drive waveform output
S27/COM2
Display forced off (VSS level)
Scan drive waveform output
S26/COM3
Display forced off (VSS level)
Scan drive waveform output
S25/COM4
Display forced off (VSS level)
Turn off waveform output
S5
Display forced off (VSS level)
Turn off waveform output
S6
Display forced off (VSS level)
Turn off waveform output
S7
Display forced off (VSS level)
Turn off waveform output
S24
S28
Display forced off (VSS level)
Display forced off (VSS level)
S1/P1
S2/P2
S3/P3
S4/P4
S28 pin unused (VSS level)
Forced off (VSS level)
Turn off waveform output (LED OFF)
Forced off (VSS level)
Turn off waveform output (LED OFF)
Forced off (VSS level)
Turn off waveform output (LED OFF)
Forced off (VSS level)
Turn off waveform output (LED OFF)
(1)
(2)
(3)
< Operation sequence >
(1) Power-on.
(2) The initial setting command is transferred after passage of “Serial data input wait time (t1 > 1 [ms])”.
(3) The display forced off is cancelled by setting the /INH pin to High(VDD) after passage of “Command execute wait time (tc > 10 [us])”.
< Transfer instruction data >
Note 1 : CCB address = (44)h, D1 to D16= all “0” data, D17 to D100= all “0” data,
DT0=0 and DT1=0 (1/4-duty),
W10 to W15=1,1,1,1,1,0 (Brightness is 50%),
W20 to W25=1,1,1,1,1,0 (Brightness is 50%),
W30 to W35=1,1,1,1,1,1 (Brightness is 100%),
PF0=0, PF1=1, PF2=0 and PF3=0 (fp=234.37 [Hz]),
PS10=0 and PS11=0 (S1/P1=Low level general-purpose output),
PS20=0 and PS21=0 (S2/P2=Low level general-purpose output),
PS30=0 and PS31=0 (S3/P3=Low level general-purpose output),
PS40=0 and PS41=0 (S4/P4=Low level general-purpose output),
P0=1, P1=0 and P2=0 (S1/P1 to S4/P4 are set by general-purpose output port (P1 to P4)),
FC0=0, FC1=1, FC2=0 and FC3=1 (fo=97.66 [Hz]),
DN=0 (S28 pin unused), EXF=0 and OC=0 (Internal oscillator operating mode),
SC=0 (“All segment turn off mode” was cancelled), BU=0 (“Power saving mode” was cancelled).
http://onsemi.com
17
LC75843UGA Application Note
(2) Timing Chart of the LCD Display Contents Change
Next, the following figure shows the timing waveform of the LCD display contents change. For example, when S5
segment corresponding to COM1 is ON and S6 segment corresponding to COM2 is ON, the following figures shows
the segment to change.
VDD
+5.0 [V]
/INH
High
CE
CL
DI
Note 2
fo = 97.66 [Hz]
Scan drive waveform output
OFF OFF OFF
ON
OFF OFF OFF
COM1
Scan drive waveform output
ON
OFF OFF OFF
Scan drive waveform output
OFF
ON
Scan drive waveform output
OFF OFF
ON
OFF OFF
S27/COM2
OFF OFF OFF
ON
OFF
OFF OFF OFF
ON
S26/COM3
ON
S25/COM4
OFF OFF OFF
Turn off waveform output
ON
OFF OFF OFF
S5
ON
Turn off waveform output
OFF OFF OFF
ON
OFF OFF
S6
Turn off waveform output
OFF OFF OFF OFF OFF OFF OFF
Turn off waveform output
OFF OFF OFF OFF OFF OFF OFF
S7
S24
S28
S1/P1
S2/P2
S3/P3
S4/P4
S28 pin unused (VSS level)
Turn off waveform output (LED OFF)
Turn off waveform output (LED OFF)
Turn off waveform output (LED OFF)
Turn off waveform output (LED OFF)
(4)
< Operation sequence >
(4) The command of the LCD display change is transferred.
< Transfer instruction data >
Note 2 : CCB address = (44)h, D1 to D16=all “0” data,
D17=1, D18=0, D19=0, D20=0, D21=0, D22=1, D23=0, D24=0, D25 to D100=all “0” data,
DT0=0 and DT1=0 (1/4-duty),
W10 to W15=1,1,1,1,1,0 (Brightness is 50%),
W20 to W25=1,1,1,1,1,0 (Brightness is 50%),
W30 to W35=1,1,1,1,1,1 (Brightness is 100%),
PF0=0, PF1=1, PF2=0 and PF3=0 (fp=234.37 [Hz]),
PS10=0 and PS11=0 (S1/P1=Low level general-purpose output),
PS20=0 and PS21=0 (S2/P2=Low level general-purpose output),
PS30=0 and PS31=0 (S3/P3=Low level general-purpose output),
PS40=0 and PS41=0 (S4/P4=Low level general-purpose output),
P0=1, P1=0 and P2=0 (S1/P1 to S4/P4 are set by general-purpose output port (P1 to P4)),
FC0=0, FC1=1, FC2=0 and FC3=1 (fo=97.66 [Hz]),
DN=0 (S28 pin unused), EXF=0 and OC=0 (Internal oscillator operating mode),
SC=0 (“All segment turn off mode” was cancelled), BU=0 (“Power saving mode” was cancelled).
http://onsemi.com
18
LC75843UGA Application Note
(3) Timing Chart of the Setting to Turn on the LED of Backlight
Next, the following figure shows the timing waveform of turn on the LED of backlight (Brightness is 100%)
connecting to S4/P4 output pin.
VDD
+5.0 [V]
/INH
High
CE
CL
DI
Note 3
fo = 97.66 [Hz]
Scan drive waveform output
COM1
Scan drive waveform output
S27/COM2
Scan drive waveform output
S26/COM3
Scan drive waveform output
S25/COM4
S5
S6
S7
S24
S28
S1/P1
S2/P2
S3/P3
S4/P4
S28 pin unused (VSS level)
Low level general-purpose output (LED OFF)
Low level general-purpose output (LED OFF)
Low level general-purpose output (LED OFF)
PWM output (PWM duty=64/64=100%)
VDD
Low level general-purpose output (LED OFF)
(5)
< Operation sequence >
(5) The command of the LED control is transferred.
< Transfer instruction data >
Note 3 : CCB address = (44)h, D1 to D16=all “0” data,
D17=1, D18=0, D19=0, D20=0, D21=0, D22=1, D23=0, D24=0, D25 to D100=all “0” data,
DT0=0 and DT1=0 (1/4-duty),
W10 to W15=1,1,1,1,1,0 (Brightness is 50%),
W20 to W25=1,1,1,1,1,0 (Brightness is 50%),
W30 to W35=1,1,1,1,1,1 (Brightness is 100%),
PF0=0, PF1=1, PF2=0 and PF3=0 (fp=234.37 [Hz]),
PS10=0 and PS11=0 (S1/P1=Low level general-purpose output),
PS20=0 and PS21=0 (S2/P2=Low level general-purpose output),
PS30=0 and PS31=0 (S3/P3=Low level general-purpose output),
PS40=1 and PS41=1 (S4/P4=PWM output function (ch3) setting),
P0=1, P1=0 and P2=0 (S1/P1 to S4/P4 are set by general-purpose output port (P1 to P4)),
FC0=0, FC1=1, FC2=0 and FC3=1 (fo=97.66 [Hz]),
DN=0 (S28 pin unused), EXF=0 and OC=0 (Internal oscillator operating mode),
SC=0 (“All segment turn off mode” was cancelled), BU=0 (“Power saving mode” was cancelled).
http://onsemi.com
19
LC75843UGA Application Note
(4) Timing Chart of the Setting to Turn on the LED of Button Indicator A
Next, the following figure shows the timing waveform of turn on the LED of button indicator A (Brightness is 50%)
connecting to S1/P1 output pin.
VDD
+5.0 [V]
/INH
High
CE
CL
DI
Note 4
fo = 97.66 [Hz]
Scan drive waveform output
COM1
Scan drive waveform output
S27/COM2
Scan drive waveform output
S26/COM3
Scan drive waveform output
S25/COM4
S5
S6
S7
S24
S28
S28 pin unused (VSS level)
fp = 234.37 [Hz]
PWM output (PWM duty=32/64=50%)
S1/P1
S2/P2
S3/P3
S4/P4
Low level general-purpose output (LED OFF)
Low level general-purpose output (LED OFF)
Low level general-purpose output (LED OFF)
PWM output (PWM duty=64/64=100%)
VDD
(6)
< Operation sequence >
(6) The command of the LED control is transferred.
< Transfer instruction data >
Note 4 : CCB address = (44)h, D1 to D16=all “0” data,
D17=1, D18=0, D19=0, D20=0, D21=0, D22=1, D23=0, D24=0, D25 to D100=all “0” data,
DT0=0 and DT1=0 (1/4-duty),
W10 to W15=1,1,1,1,1,0 (Brightness is 50%),
W20 to W25=1,1,1,1,1,0 (Brightness is 50%),
W30 to W35=1,1,1,1,1,1 (Brightness is 100%),
PF0=0, PF1=1, PF2=0 and PF3=0 (fp=234.37 [Hz]),
PS10=1 and PS11=1 (S1/P1=PWM output function (ch1) setting),
PS20=0 and PS21=0 (S2/P2=Low level general-purpose output),
PS30=0 and PS31=0 (S3/P3=Low level general-purpose output),
PS40=1 and PS41=1 (S4/P4=PWM output function (ch3) setting),
P0=1, P1=0 and P2=0 (S1/P1 to S4/P4 are set by general-purpose output port (P1 to P4)),
FC0=0, FC1=1, FC2=0 and FC3=1 (fo=97.66 [Hz]),
DN=0 (S28 pin unused), EXF=0 and OC=0 (Internal oscillator operating mode),
SC=0 (“All segment turn off mode” was cancelled), BU=0 (“Power saving mode” was cancelled).
http://onsemi.com
20
LC75843UGA Application Note
(5) Timing Chart of the Setting to Turn on the LED of Button Indicator B
Next, the following figure shows the timing waveform of turn off the LED of button indicator A connecting to S1/P1
output pin, and turn on the LED of button indicator B (Brightness is 50%) connecting to S2/P2 output pin.
VDD
+5.0 [V]
/INH
High
CE
CL
DI
Note 5
fo = 97.66 [Hz]
Scan drive waveform output
COM1
Scan drive waveform output
S27/COM2
Scan drive waveform output
S26/COM3
Scan drive waveform output
S25/COM4
S5
S24
S28
S28 pin unused (VSS level)
fp = 234.37 [Hz]
PWM output (PWM duty=32/64=50%)
Low level general-purpose output (LED OFF)
S1/P1
PWM output (PWM duty=32/64=50%)
S2/P2
S3/P3
S4/P4
Low level general-purpose output (LED OFF)
Low level general-purpose output (LED OFF)
PWM output (PWM duty=64/64=100%)
VDD
(7)
< Operation sequence >
(7) The command of the LED control is transferred.
< Transfer instruction data >
Note 5 : CCB address = (44)h, D1 to D16=all “0” data,
D17=1, D18=0, D19=0, D20=0, D21=0, D22=1, D23=0, D24=0, D25 to D100=all “0” data,
DT0=0 and DT1=0 (1/4-duty),
W10 to W15=1,1,1,1,1,0 (Brightness is 50%),
W20 to W25=1,1,1,1,1,0 (Brightness is 50%),
W30 to W35=1,1,1,1,1,1 (Brightness is 100%),
PF0=0, PF1=1, PF2=0 and PF3=0 (fp=234.37 [Hz]),
PS10=0 and PS11=0 (S1/P1=Low level general-purpose output),
PS20=1 and PS21=0 (S2/P2=PWM output function (ch1) setting),
PS30=0 and PS31=0 (S3/P3=Low level general-purpose output),
PS40=1 and PS41=1 (S4/P4=PWM output function (ch3) setting),
P0=1, P1=0 and P2=0 (S1/P1 to S4/P4 are set by general-purpose output port (P1 to P4)),
FC0=0, FC1=1, FC2=0 and FC3=1 (fo=97.66 [Hz]),
DN=0 (S28 pin unused), EXF=0 and OC=0 (Internal oscillator operating mode),
SC=0 (“All segment turn off mode” was cancelled), BU=0 (“Power saving mode” was cancelled).
http://onsemi.com
21
LC75843UGA Application Note
(6) Timing Chart of the Setting to Turn on the LED of Button Indicator A to C
Next, the following figure shows the timing waveform of turn on the LED of button indicator A to C connecting to
S1/P1 to S3/P3 output pin.
VDD
+5.0 [V]
/INH
High
CE
CL
DI
Note 6
fo = 97.66 [Hz]
Scan drive waveform output
COM1
Scan drive waveform output
S27/COM2
Scan drive waveform output
S26/COM3
Scan drive waveform output
S25/COM4
S5
S24
S28
S28 pin unused (VSS level)
fp = 234.37 [Hz]
PWM output (PWM duty=32/64=50%)
S1/P1
Low level general-purpose output (LED OFF)
PWM output (PWM duty=32/64=50%)
S2/P2
PWM output (PWM duty=32/64=50%)
S3/P3
S4/P4
Low level general-purpose output (LED OFF)
PWM output (PWM duty=64/64=100%)
VDD
(8)
< Operation sequence >
(8) The command of the LED control is transferred.
< Transfer instruction data >
Note 6 : CCB address = (44)h, D1 to D16=all “0” data,
D17=1, D18=0, D19=0, D20=0, D21=0, D22=1, D23=0, D24=0, D25 to D100=all “0” data,
DT0=0 and DT1=0 (1/4-duty),
W10 to W15=1,1,1,1,1,0 (Brightness is 50%),
W20 to W25=1,1,1,1,1,0 (Brightness is 50%),
W30 to W35=1,1,1,1,1,1 (Brightness is 100%),
PF0=0, PF1=1, PF2=0 and PF3=0 (fp=234.37 [Hz]),
PS10=1 and PS11=1 (S1/P1=PWM output function (ch1) setting),
PS20=1 and PS21=0 (S2/P2=PWM output function (ch1) setting),
PS30=0 and PS31=1 (S3/P3=PWM output function (ch2) setting),
PS40=1 and PS41=1 (S4/P4=PWM output function (ch3) setting),
P0=1, P1=0 and P2=0 (S1/P1 to S4/P4 are set by general-purpose output port (P1 to P4)),
FC0=0, FC1=1, FC2=0 and FC3=1 (fo=97.66 [Hz]),
DN=0 (S28 pin unused), EXF=0 and OC=0 (Internal oscillator operating mode),
SC=0 (“All segment turn off mode” was cancelled), BU=0 (“Power saving mode” was cancelled).
http://onsemi.com
22
LC75843UGA Application Note
(7) Timing Chart of the Setting to Change the Brightness of the LED
Next, the following figure shows the timing waveform of the LED brightness change (Brightness is 79.69%) of
button indicator C connecting to S3/P3 output pin.
VDD
+5.0 [V]
/INH
High
CE
CL
DI
Note 7
fo = 97.66 [Hz]
Scan drive waveform output
COM1
Scan drive waveform output
S27/COM2
Scan drive waveform output
S26/COM3
Scan drive waveform output
S25/COM4
S5
S24
S28
S28 pin unused (VSS level)
fp = 234.37 [Hz]
PWM output (PWM duty=32/64=50%)
S1/P1
PWM output (PWM duty=32/64=50%)
S2/P2
PWM output (PWM duty=32/64=50%)
PWM output (PWM duty=51/64=79.69%)
S3/P3
S4/P4
PWM output (PWM duty=64/64=100%)
VDD
(9)
< Operation sequence >
(9) The command of the LED control is transferred.
< Transfer instruction data >
Note 7 : CCB address = (44)h, D1 to D16=all “0” data,
D17=1, D18=0, D19=0, D20=0, D21=0, D22=1, D23=0, D24=0, D25 to D100=all “0” data,
DT0=0 and DT1=0 (1/4-duty),
W10 to W15=1,1,1,1,1,0 (Brightness is 50%),
W20 to W25=0,1,0,0,1,1 (Brightness is 79.69%),
W30 to W35=1,1,1,1,1,1 (Brightness is 100%),
PF0=0, PF1=1, PF2=0 and PF3=0 (fp=234.37 [Hz]),
PS10=1 and PS11=1 (S1/P1=PWM output function (ch1) setting),
PS20=1 and PS21=0 (S2/P2=PWM output function (ch1) setting),
PS30=0 and PS31=1 (S3/P3=PWM output function (ch2) setting),
PS40=1 and PS41=1 (S4/P4=PWM output function (ch3) setting),
P0=1, P1=0 and P2=0 (S1/P1 to S4/P4 are set by general-purpose output port (P1 to P4)),
FC0=0, FC1=1, FC2=0 and FC3=1 (fo=97.66 [Hz]),
DN=0 (S28 pin unused), EXF=0 and OC=0 (Internal oscillator operating mode),
SC=0 (“All segment turn off mode” was cancelled), BU=0 (“Power saving mode” was cancelled).
http://onsemi.com
23
LC75843UGA Application Note
(8) Timing Chart of the Setting to Turn off the Segments and Turn off the LED of Backlight
Next, the following figure shows the timing waveform of the display OFF (turn off the all segments) and turn off the
LED of backlight.
VDD
+5.0 [V]
/INH
High
CE
CL
DI
Note 8
fo = 97.66 [Hz]
Scan drive waveform output
COM1
Scan drive waveform output
S27/COM2
Scan drive waveform output
S26/COM3
Scan drive waveform output
S25/COM4
Turn off waveform output
S5
Turn off waveform output
S6
Turn off waveform output
S7
Turn off waveform output
S24
S28
S28 pin unused (VSS level)
fp = 234.37 [Hz]
PWM output (PWM duty=32/64=50%)
S1/P1
PWM output (PWM duty=32/64=50%)
S2/P2
PWM output (PWM duty=51/64=79.69%)
S3/P3
S4/P4
PWM output (PWM duty=64/64=100%)
VDD
Low level general-purpose output (LED OFF)
(10)
< Operation sequence >
(10) The command of the turn off the segments and turn off the LED of backlight setting is transferred.
< Transfer instruction data >
Note 8 : CCB address = (44)h, D1 to D16=all “0” data,
D17=1, D18=0, D19=0, D20=0, D21=0, D22=1, D23=0, D24=0, D25 to D100=all “0” data,
DT0=0 and DT1=0 (1/4-duty),
W10 to W15=1,1,1,1,1,0 (Brightness is 50%),
W20 to W25=0,1,0,0,1,1 (Brightness is 79.69%),
W30 to W35=1,1,1,1,1,1 (Brightness is 100%),
PF0=0, PF1=1, PF2=0 and PF3=0 (fp=234.37 [Hz]),
PS10=1 and PS11=1 (S1/P1=PWM output function (ch1) setting),
PS20=1 and PS21=0 (S2/P2=PWM output function (ch1) setting),
PS30=0 and PS31=1 (S3/P3=PWM output function (ch2) setting),
PS40=0 and PS41=0 (S4/P4=Low level general-purpose output),
P0=1, P1=0 and P2=0 (S1/P1 to S4/P4 are set by general-purpose output port (P1 to P4)),
FC0=0, FC1=1, FC2=0 and FC3=1 (fo=97.66 [Hz]),
DN=0 (S28 pin unused), EXF=0 and OC=0 (Internal oscillator operating mode),
SC=1 (Set the “All segment turn off mode”),
BU=0 (“Power saving mode” was cancelled).
http://onsemi.com
24
LC75843UGA Application Note
(9) Timing Chart from LCD Display OFF to Power-off State
Finally, the following figure shows the timing waveform to set by power-off state from LCD display OFF.
VDD
+5.0 [V]
t2 > 0 [ms]
/INH
High
CE
Low
CL
Low
DI
Low
Low
fo = 97.66 [Hz]
Scan drive waveform output
Display forced off (VSS level)
COM1
Scan drive waveform output
Display forced off (VSS level)
S27/COM2
Scan drive waveform output
Display forced off (VSS level)
S26/COM3
Scan drive waveform output
Display forced off (VSS level)
S25/COM4
Turn off waveform output
Display forced off (VSS level)
S5
Turn off waveform output
Display forced off (VSS level)
S6
Turn off waveform output
Display forced off (VSS level)
S7
Turn off waveform output
Display forced off (VSS level)
S24
S28
S28 pin unused (VSS level)
Display forced off (VSS level)
fp = 234.37 [Hz]
PWM output (PWM duty=32/64=50%)
Forced off (VSS level)
S1/P1
PWM output (PWM duty=32/64=50%)
Forced off (VSS level)
S2/P2
PWM output (PWM duty=51/64=79.69%)
Forced off (VSS level)
S3/P3
S4/P4
Low level general-purpose output
Forced off (VSS level)
(11)
< Operation sequence >
(11) The display forced off is set by setting the /INH pin to Low (VSS).
(12) Power-off.
http://onsemi.com
25
(12)
LC75843UGA Application Note
Application Circuit
(1) In the Case of the LCD System Configuration Using the LCD Panel of 84 Segments
VOUP
(Pull-up power supply for LED)
LCD Driver IC
(LC75843UGA)
+5.0 [V]
S1/P1
(Button indicator A)
S2/P2
(Button indicator B)
S3/P3
(Button indicator C)
VDD
VSS
S4/P4
OSCI
(Backlight)
21
S5 to S24
LCD
Controller
S28
/INH
3
(CCB interface)
CE
CL
DI
S25/COM4
S26/COM3
S27/COM2
COM1
LCD Panel
(4com x 21seg = 84 segments)
Figure 12. LCD system configuration using the LCD panel of 84 segments
The LC75843UGA is able to drive up to 84 segments the LCD panel of the 1/4-duty when the output pins from
S1/P1 to S4/P4 used general-purpose output ports (P1 to P4).
The following explains a setting method example of serial control data in this case.
This system sets DT0=0 and DT1=0 to use an LCD panel of the 1/4-duty drive.
DT0
DT1
LCD drive type
0
1
0
1
0
0
1
1
1/4-duty and 1/3-bias drive type
1/3-duty and 1/3-bias drive type
1/2-duty and 1/2-bias drive type
Static (1/1-duty) drive type
COM1
COM1
COM1
COM1
COM1
Output pins state
COM2/S27 COM3/S26 COM4/S25
COM2
COM2
COM2
S27
COM3
COM3
S26
S26
COM4
S25
S25
S25
This system sets DN=1 to use S28 output terminal as the segment output.
DN
0
1
S28 output pin state
VSS level output
S28 segment output
This system sets LCD display data from D17 to D100 to use LCD segments from S5 to S24, and S28. In addition,
the pins from S1/P1 to S4/P4 use general-purpose output port function. Therefore, sets the general-purpose output
ports (P1 to P4) of high level output or low level output by D1 to D16. When sets the “1/4-duty drive mode”, the
following table shows the relation between the Display data setting registers (D17 to D100) and the segment outputs
and the common outputs.
http://onsemi.com
26
LC75843UGA Application Note
Output pin
COM1
COM2/S27
COM3/S26
COM4/S25
S5
S6
S7
S8
S9
S10
S11
S12
S13
S14
S15
S16
S17
S18
S19
S20
S21
S22
S23
S24
S28
D17
D21
D25
D29
D33
D37
D41
D45
D49
D53
D57
D61
D65
D69
D73
D77
D81
D85
D89
D93
D97
D18
D22
D26
D30
D34
D38
D42
D46
D50
D54
D58
D62
D66
D70
D74
D78
D82
D86
D90
D94
D98
D19
D23
D27
D31
D35
D39
D43
D47
D51
D55
D59
D63
D67
D71
D75
D79
D83
D87
D91
D95
D99
D20
D24
D28
D32
D36
D40
D44
D48
D52
D56
D60
D64
D68
D72
D76
D80
D84
D88
D92
D96
D100
This system sets output pins from S1/P1 to S4/P4 to a general-purpose output port and controls LED. Therefore,
this system sets P0=1, P1=0 and P2=0.
P0
P1
P2
0
0
0
0
1
1
1
1
0
0
1
1
0
0
1
1
0
1
0
1
0
1
0
1
S1/P1
S1
P1
P1
P1
P1
S1
S1
S1
Output pin state
S2/P2
S3/P3
S2
S3
S2
S3
P2
S3
P2
P3
P2
P3
S2
S3
S2
S3
S2
S3
S4/P4
S4
S4
S4
S4
P4
S4
S4
S4
S1 to S4 : Segment output ports
P1 to P4 : General-purpose output ports
The registers of the PS10 and PS11 can set the “General-purpose output function”, “Clock output function”, or
“PWM output function” of the general-purpose output port (P1). In addition, the registers of the PS20, PS21, PS30,
PS31, PS40 and PS41 can set the “General-purpose output function” or “PWM output function” of the generalpurpose output ports (P2, P3 and P4). The general-purpose output function outputs general-purpose output ports
(P1 to P4) of high level or low level by “Display data setting registers (D1, D5, D9 and D13)”. The PWM output
function can set the pulse width of the PWM output by “PWM duty setting register (W10 to W15, W20 to W25 and
W30 to W35)”. The PWM duty setting has up to 3ch and can perform brightness adjustment of the LED individually
for each channel.
The setting method about the registers except the above is the same as “Explanation of the LCD drive control”,
“Explanation of the LED Control by General-purpose Output Ports” and “Explanation of the Instruction Data”.
http://onsemi.com
27
LC75843UGA Application Note
(2) In the Case of the LCD System Configuration Using the LCD Panel of 88 Segments
VOUP
(Pull-up power supply for LED)
LCD Driver IC
(LC75843UGA)
+5.0 [V]
S1/P1
(Button indicator A)
S2/P2
(Button indicator C)
VDD
VSS
S3/P3
(Backlight)
OSCI
22
P4/S4
S5 to S24
LCD
Controller
S28
/INH
3
(CCB interface)
CE
CL
DI
S25/COM4
S26/COM3
S27/COM2
LCD Panel
(4com x 22seg = 88 segments)
COM1
Figure 13. LCD system configuration using the LCD panel of 88 segments
The output pins from S1/P1 to S4/P4 of the LC75843UGA can set the “Segment output port” or “General-purpose
output port”. This IC is able to drive up to 88 segments the LCD panel of the 1/4-duty when the output pins from
S1/P1 to S3/P3 used general-purpose output ports (P1 to P3) and the S4/P4 output pin used segment output port
(S4). The following explains a setting method example of serial control data in this case.
This system sets DT0=0 and DT1=0 to use an LCD panel of the 1/4-duty drive.
DT0
DT1
LCD drive type
0
1
0
1
0
0
1
1
1/4-duty and 1/3-bias drive type
1/3-duty and 1/3-bias drive type
1/2-duty and 1/2-bias drive type
Static (1/1-duty) drive type
COM1
COM1
COM1
COM1
COM1
Output pins state
COM2/S27 COM3/S26 COM4/S25
COM2
COM2
COM2
S27
COM3
COM3
S26
S26
COM4
S25
S25
S25
This system sets DN=1 to use S28 output terminal as the segment output.
DN
0
1
S28 output pin state
VSS level output
S28 segment output
This system sets LCD display data from D13 to D100 to use LCD segments from S4 to S24, and S28. In addition,
the pins from S1/P1 to S3/P3 use general-purpose output port function. Therefore, sets the general-purpose output
ports (P1 to P3) of high level output or low level output by D1 to D12. When sets the “1/4-duty drive mode”, the
following table shows the relation between the Display data setting registers (D13 to D100) and the segment outputs
and the common outputs.
http://onsemi.com
28
LC75843UGA Application Note
Output pin
COM1
COM2/S27
COM3/S26
COM4/S25
S4/P4
S5
S6
S7
S8
S9
S10
S11
S12
S13
S14
S15
S16
S17
S18
S19
S20
S21
S22
S23
S24
S28
D13
D17
D21
D25
D29
D33
D37
D41
D45
D49
D53
D57
D61
D65
D69
D73
D77
D81
D85
D89
D93
D97
D14
D18
D22
D26
D30
D34
D38
D42
D46
D50
D54
D58
D62
D66
D70
D74
D78
D82
D86
D90
D94
D98
D15
D19
D23
D27
D31
D35
D39
D43
D47
D51
D55
D59
D63
D67
D71
D75
D79
D83
D87
D91
D95
D99
D16
D20
D24
D28
D32
D36
D40
D44
D48
D52
D56
D60
D64
D68
D72
D76
D80
D84
D88
D92
D96
D100
When the S1/P1 to S3/P3 output pins used general-purpose output ports (P1 to P3) and when the S4/P4 output pin
used segment output port (S4), this system sets P0=0, P1=1 and P2=1.
P0
P1
P2
0
0
0
0
1
1
1
1
0
0
1
1
0
0
1
1
0
1
0
1
0
1
0
1
S1/P1
S1
P1
P1
P1
P1
S1
S1
S1
Output pin state
S2/P2
S3/P3
S2
S3
S2
S3
P2
S3
P2
P3
P2
P3
S2
S3
S2
S3
S2
S3
S4/P4
S4
S4
S4
S4
P4
S4
S4
S4
S1 to S4 : Segment output ports
P1 to P4 : General-purpose output ports
The registers of the PS10 and PS11 can set the “General-purpose output function”, “Clock output function”, or
“PWM output function” of the general-purpose output port (P1). In addition, the registers of the PS20, PS21, PS30
and PS31 can set the “General-purpose output function” or “PWM output function” of the general-purpose output
ports (P2 and P3). The general-purpose output function outputs general-purpose output ports (P1 to P3) of high level
or low level by “Display data setting registers (D1, D5 and D9)”.
This system does not use the registers of the PS40 and PS41. Therefore, those set all “0”.
The setting method about the registers except the above is the same as “Explanation of the LCD drive control”,
“Explanation of the LED Control by General-purpose Output Ports” and “Explanation of the Instruction Data”.
http://onsemi.com
29
LC75843UGA Application Note
(3) In the Case of the LCD System Configuration Using the LCD Panel of 100 Segments
LCD Driver IC
(LC75843UGA)
+5.0 [V]
VDD
VSS
25
P1/S1
P2/S2
P3/S3
OSCI
P4/S4
S5 to S24
S28
LCD
Controller
/INH
3
(CCB interface)
CE
CL
DI
S25/COM4
S26/COM3
S27/COM2
COM1
LCD Panel
(4com x 25seg = 100 segments)
Figure 14. LCD system configuration using the LCD panel of 100 segments
The LC75843UGA is able to drive up to 100 segments the LCD panel of the 1/4-duty when the output pins from
S1/P1 to S4/P4 used segment output ports (S1 to S4).
The following explains a setting method example of serial control data in this case.
This system sets DT0=0 and DT1=0 to use an LCD panel of the 1/4-duty drive.
DT0
DT1
LCD drive type
0
1
0
1
0
0
1
1
1/4-duty and 1/3-bias drive type
1/3-duty and 1/3-bias drive type
1/2-duty and 1/2-bias drive type
Static (1/1-duty) drive type
COM1
COM1
COM1
COM1
COM1
Output pins state
COM2/S27 COM3/S26 COM4/S25
COM2
COM2
COM2
S27
COM3
COM3
S26
S26
COM4
S25
S25
S25
This system sets DN=1 to use S28 output terminal as the segment output.
DN
0
1
S28 output pin state
VSS level output
S28 segment output
This system sets LCD display data from D1 to D100 to use LCD segments from S1 to S24, and S28. When sets the
“1/4-duty drive mode”, the following table shows the relation between the Display data setting registers (D1 to D100)
and the segment outputs and the common outputs.
http://onsemi.com
30
LC75843UGA Application Note
Output pin
COM1
COM2/S27
COM3/S26
COM4/S25
S1/P1
S2/P2
S3/P3
S4/P4
S5
S6
S7
S8
S9
S10
S11
S12
S13
S14
S15
S16
S17
S18
S19
S20
S21
S22
S23
S24
S28
D1
D5
D9
D13
D17
D21
D25
D29
D33
D37
D41
D45
D49
D53
D57
D61
D65
D69
D73
D77
D81
D85
D89
D93
D97
D2
D6
D10
D14
D18
D22
D26
D30
D34
D38
D42
D46
D50
D54
D58
D62
D66
D70
D74
D78
D82
D86
D90
D94
D98
D3
D7
D11
D15
D19
D23
D27
D31
D35
D39
D43
D47
D51
D55
D59
D63
D67
D71
D75
D79
D83
D87
D91
D95
D99
D4
D8
D12
D16
D20
D24
D28
D32
D36
D40
D44
D48
D52
D56
D60
D64
D68
D72
D76
D80
D84
D88
D92
D96
D100
This system sets output pins from S1/P1 to S4/P4 to a segment output port and drives LCD segment. Therefore
this system sets P0=0, P1=0 and P2=0.
P0
P1
P2
0
0
0
0
1
1
1
1
0
0
1
1
0
0
1
1
0
1
0
1
0
1
0
1
S1/P1
S1
P1
P1
P1
P1
S1
S1
S1
Output pin state
S2/P2
S3/P3
S2
S2
P2
P2
P2
S2
S2
S2
S3
S3
S3
P3
P3
S3
S3
S3
S4/P4
S4
S4
S4
S4
P4
S4
S4
S4
S1 to S4 : Segment output ports
P1 to P4 : General-purpose output ports
This system does not use the registers of the PS10, PS11, PS20, PS21, PS30, PS31, PS40, PS41, W10 to W15,
W20 to W25, W30 to W35, and PF0 to PF3. Therefore, those set all “0”.
The setting method about the registers except the above is the same as “Explanation of the LCD drive control”,
“Explanation of the LED Control by General-purpose Output Ports” and “Explanation of the Instruction Data”.
http://onsemi.com
31
LC75843UGA Application Note
(4) In the Case of the LCD System Configuration to Input an External Clock (300kHz)
VOUP
(Pull-up power supply for LED)
LCD Driver IC
(LC75843UGA)
+5.0 [V]
S1/P1
(Button indicator A)
S2/P2
(Button indicator B)
S3/P3
(Button indicator C)
VDD
VSS
S4/P4
(Backlight)
18
OSCI
LCD
Controller
/INH
CE
CL
DI
3
(CCB interface)
S5 to S22
S23
S24
S28
(open)
(open)
(open)
S25/COM4
S26/COM3
S27/COM2
COM1
LCD Panel
(4com x 18seg = 72 segments)
Figure 15. LCD system configuration to input an external clock (300kHz)
The LC75843UGA is able to set the “Internal oscillator operating mode” or “External clock input operating mode”.
Furthermore, this IC can set the division ratio a clock to input from OSCI pin becomes 300 [kHz](Typ.) or 38
[kHz](Typ.). However, when set the “External clock 38kHz input mode (OC=1 and EXF=1)”, please be careful
because PWM output function is invalidity.
The reason why a customer selects the LCD system configuration using the “External clock input operating mode”
is because the characteristic of the internal oscillator clock frequency (fosc) is uneven by a production variation and
the terms of use of the IC (Power supply voltage, temperature, etc.). Therefore the customer may worry about the
flicker of the liquid crystal display occurring by interference with other frequency. Furthermore, there may be a
customer hoping to lower clock frequency more because of the low power consumption and EMI (Electro Magnetic
Interference) measures, etc.
First of all, the following table shows the pin explanation of the external clock input pin (OSCI) and the
specifications of the allowable operating ranges.
Pin name
OSCI
Pin function
External clock input pin.
When “Internal oscillator operating mode (OC=0)”, make sure to connect OSCI to GND.
When “External clock input mode (OC=1)”, OSCI is used to input the external clock.
Allowable operating ranges at Ta= -40°C to +105°C, VSS=0V
Parameter
Symbol
Conditions
Min.
Max.
Unit
4.5
6.3
V
0.4 VDD
6.3
V
0.2 VDD
V
Power Supply Voltage
VDD
VDD
Input High Level Voltage
VIH2
OSCI
Input Low Level Voltage
VIL2
OSCI
0
Typ.
External Clock input
Frequency
fck
OSCI, External clock input operating mode
10
300
600
kHz
External Clock Duty Ratio
Dck
OSCI, External clock input operating mode
30
50
70
%
These specifications show an example, and, we have a case to change these specifications without a notice
for improvement. Therefore, it is not guaranteed for design as the mass production equipment. When designing
equipment, refer to the “Delivery specification for the LC75843UGA”.
Functional operation above the stresses listed in the Recommended Operating Ranges is not implied. Extended exposure to stresses beyond the Recommended
Operating Ranges limits may affect device reliability.
http://onsemi.com
32
LC75843UGA Application Note
The following explains a setting method example of serial control data in this case.
This system sets OC=1 and EXF=0 to use the “External clock 300kHz input mode”
OC
0
1
1
EXF
0/1
0
1
Fundamental clock operating mode
Internal oscillator operating mode
External clock 300kHz input mode
External clock 38kHz input mode
OSCI input pin state
Connect to GND
Inputs a clock of 300 [kHz](Typ.)
Inputs a clock of 38 [kHz](Typ.)
The registers from FC0 to FC3 can set the frame frequency (fo) of the common and segment output waveform.
When sets OC=1 and EXF=0, the following table shows the frame frequency of the LCD drive waveform.
FC0
FC1
FC2
FC3
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
0
0
0
0
1
1
1
1
0
0
0
0
1
1
1
1
0
0
1
1
0
0
1
1
0
0
1
1
0
0
1
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
External clock 300kHz input operating mode (OC=1, EXF=0)
LCD drive waveform frame frequency
fo [Hz]
LCD drive waveform frame ratio
(External clock input frequency is
fck=300 [kHz](typ.))
fck / 6144
48.83
fck / 5376
55.80
fck / 4608
65.10
fck / 3840
78.12
fck / 3456
86.80
fck / 3072
97.66
fck / 2688
111.61
fck / 2304
130.21
fck / 2112
142.04
fck / 1920
156.25
fck / 1728
173.61
fck / 1536
195.31
fck / 1344
223.21
fck / 1152
260.42
fck / 960
312.50
fck / 768
390.62
The explanation mentioned above is used only to explain internal operation and how to IC, and the
characteristic of the products is uneven by a production variation and the terms of use of the IC (Power supply
voltage, temperature, etc.). Therefore, the customer should always evaluate and test devices mounted in the
customer’s products or equipment.
The registers from PF0 to PF3 can set the PWM output frame frequency (fp) of the general-purpose output port.
When sets OC=1 and EXF=0, the following table shows the frame frequency of the PWM output waveform.
PF0
PF1
PF2
PF3
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
0
1
1
0
0
1
1
0
0
1
1
0
0
1
1
0
0
0
0
1
1
1
1
0
0
0
0
1
1
1
1
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
External clock 300kHz input operating mode (OC=1, EXF=0)
PWM output waveform frame frequency
fp [Hz]
PWM output waveform frame ratio
(External clock input frequency is
fck=300 [kHz](typ.))
fck / 1536
195.31
fck / 1408
213.07
fck / 1280
234.37
fck / 1152
260.42
fck / 1024
292.97
fck / 896
334.82
fck / 768
390.62
fck / 640
468.75
fck / 512
585.94
fck / 384
781.25
fck / 256
1171.87
fck / 896
334.82
fck / 896
334.82
fck / 896
334.82
fck / 896
334.82
fck / 896
334.82
The explanation mentioned above is used only to explain internal operation and how to IC, and the
characteristic of the products is uneven by a production variation and the terms of use of the IC (Power supply
voltage, temperature, etc.). Therefore, the customer should always evaluate and test devices mounted in the
customer’s products or equipment.
The setting method about the registers except the above is the same as “Explanation of the LCD drive control”,
“Explanation of the LED Control by General-purpose Output Ports” and “Explanation of the Instruction Data”.
http://onsemi.com
33
LC75843UGA Application Note
(5) In the Case of the LCD System Configuration to Input an External Clock (38kHz)
LCD Driver IC
(LC75843UGA)
+5.0 [V]
VDD
VSS
P1/S1
(open)
P2/S2
(open)
P3/S3
(open)
P4/S4
(open)
18
OSCI
LCD
Controller
/INH
CE
CL
DI
3
(CCB interface)
S5 to S22
S23
S24
S28
(open)
(open)
(open)
S25/COM4
S26/COM3
S27/COM2
COM1
LCD Panel
(4com x 18seg = 72 segments)
Figure 16. LCD system configuration to input an external clock (38kHz)
The LC75843UGA is able to set the “Internal oscillator operating mode” or “External clock input operating mode”.
Furthermore, this IC can set the division ratio a clock to input from OSCI pin becomes 300 [kHz](Typ.) or 38
[kHz](Typ.). However, when set the “External clock 38kHz input mode (OC=1 and EXF=1)”, please be careful
because PWM output function is invalidity.
The following explains a setting method example of serial control data in this case.
This system sets OC=1 and EXF=1 to use the “External clock 38kHz input mode”
OC
0
1
1
EXF
0/1
0
1
Fundamental clock operating mode
Internal oscillator operating mode
External clock 300kHz input mode
External clock 38kHz input mode
OSCI input pin state
Connect to GND
Inputs a clock of 300 [kHz](Typ.)
Inputs a clock of 38 [kHz](Typ.)
The registers from FC0 to FC3 can set the frame frequency (fo) of the common and segment output waveform.
When sets OC=1 and EXF=1, the following table shows the frame frequency of the LCD drive waveform.
FC0
FC1
FC2
FC3
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
0
0
0
0
1
1
1
1
0
0
0
0
1
1
1
1
0
0
1
1
0
0
1
1
0
0
1
1
0
0
1
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
External clock 38kHz input operating mode (OC=1, EXF=1)
LCD drive waveform frame frequency
fo [Hz]
LCD drive waveform frame ratio
(External clock input frequency is
fck=38 [kHz](typ.))
fck / 768
49.48
fck / 672
56.55
fck / 576
65.97
fck / 480
79.16
fck / 432
87.96
fck / 384
98.96
fck / 336
113.09
fck / 288
131.94
fck / 264
143.94
fck / 240
158.33
fck / 216
175.92
fck / 192
197.92
fck / 168
226.19
fck / 144
263.89
fck / 120
316.67
fck / 96
395.83
The explanation mentioned above is used only to explain internal operation and how to IC, and the
characteristic of the products is uneven by a production variation and the terms of use of the IC (Power supply
voltage, temperature, etc.). Therefore, the customer should always evaluate and test devices mounted in the
customer’s products or equipment.
http://onsemi.com
34
LC75843UGA Application Note
This system sets output pins from S1/P1 to S4/P4 to a segment output port and drives LCD segment. Therefore
this system sets P0=0, P1=0 and P2=0.
P0
P1
P2
0
0
0
0
1
1
1
1
0
0
1
1
0
0
1
1
0
1
0
1
0
1
0
1
Output pin state
S2/P2
S3/P3
S1/P1
S1
P1
P1
P1
P1
S1
S1
S1
S2
S2
P2
P2
P2
S2
S2
S2
S4/P4
S3
S3
S3
P3
P3
S3
S3
S3
S4
S4
S4
S4
P4
S4
S4
S4
S1 to S4 : Segment output ports
P1 to P4 : General-purpose output ports
This system does not use the registers of the PS10, PS11, PS20, PS21, PS30, PS31, PS40, PS41, W10 to W15,
W20 to W25, W30 to W35, and PF0 to PF3. Therefore, those set all “0”.
The setting method about the registers except the above is the same as “Explanation of the LCD drive control”,
“Explanation of the LED Control by General-purpose Output Ports” and “Explanation of the Instruction Data”.
When LED control is necessary for the LCD system configuration example of the “External clock 38kHz input
mode”, the output pins from S1/P1 to S4/P4 are set the general-purpose output ports (P1 to P4), and if it is only
setting of ON (Brightness is 100%) or OFF of the LED, it can be set. Then, this system controls LED by generalpurpose output port of the output pins from S1/P1 to S4/P4, therefore, this system sets P0=1, P1=0 and P2=0. In
addition, the general-purpose output port (P4) uses the general-purpose output function, therefore, this system sets
PS40=0 and PS41=0. Finally, the general-purpose output port (P4) outputs high level (LED turns on with 100% of
brightness) or low level (turn off the LED) by the “Display data setting register (D13)”.
LCD Driver IC
(LC75843UGA)
VOUP
+5.0 [V]
VDD
S1/P1
(open)
S2/P2
(open)
VSS
S3/P3
(open)
(Pull-up power supply for LED)
S4/P4
(Backlight)
OSCI
LCD
Controller
/INH
3
(CCB interface)
CE
CL
DI
S5 to S22
S23
S24
S28
18
(open)
(open)
(open)
S25/COM4
S26/COM3
S27/COM2
COM1
LCD Panel
(4com x 18seg = 72 segments)
Figure 17. LED control by the LCD system configuration to input an external clock (38kHz)
http://onsemi.com
35
LC75843UGA Application Note
(6) In the Case of the LCD System Configuration Using two LCD Panels.
LCD Driver IC (A)
(LC75843UGA)
+5.0 [V]
VDD
P1/S1
P2/S2
P3/S3
P4/S4
VSS
LCD
Controller
20
S5 to S24
OSCI
/INH
S28
OSCI
/INH
CEA
CEB
CL
DI
S25/COM4
S26/COM3
S27/COM2
COM1
CE
(CCB
interface)
CL
DI
LCD Panel (A)
(4com x 25seg = 100 segments)
LCD Driver IC (B)
(LC75843UGA)
VDD
P1/S1
P2/S2
P3/S3
P4/S4
VSS
20
S5 to S24
S28
OSCI
/INH
S25/COM4
S26/COM3
S27/COM2
COM1
CE
CL
DI
(CCB
interface)
LCD Panel (B)
(4com x 25seg = 100 segments)
Figure 18. LCD system configuration using two LCD panels
In the case of the system configuration using two LCD panels, the CL and DI signal of the CCB interface are input
from an LCD controller into both LC75843UGA and are controlled at the same time, and the CE signal of the CCB
interface is input from an LCD controller into LC75843UGA separately and is controlled separately.
/INH
Display forced off
Display on
CEA
CEB
CL
DI
Initialization of IC(A)
Internal data
of the IC(A)
Undefined
Internal data
of the IC(B)
Undefined
The display data of
IC(B) is changed
Initialization of IC(B)
The display data of
IC(A) is changed
Defined
Changed
Defined
Changed
Figure 19. Control example of the LCD system configuration using two LCD panels
When serial control data is transferred for LCD driver IC(A), the “Chip enable A (CEA)” signal is set to control signal,
and the “chip enable B (CEB)” signal is held to low level. When serial control data is transferred for LCD driver IC(B),
the “Chip enable A (CEA)” signal is held to low level, and the “Chip enable B (CEB)” signal is set to control signal.
Even if a control signal is input into CL and DI, the internal data of the LCD driver IC are not changed if CE signal is
heldd to low level.
http://onsemi.com
36
LC75843UGA Application Note
ON Semiconductor and the ON logo are registered trademarks of Semiconductor Components Industries, LLC (SCILLC). SCILLC owns the rights to a number
of patents, trademarks, copyrights, trade secrets, and other intellectual property. A listing of SCILLC’s product/patent coverage may be accessed at
www.onsemi.com/site/pdf/Patent-Marking.pdf. SCILLC reserves the right to make changes without further notice to any products herein. SCILLC makes no
warranty, representation or guarantee regarding the suitability of its products for any particular purpose, nor does SCILLC assume any liability arising out of the
application or use of any product or circuit, and specifically disclaims any and all liability, including without limitation special, consequential or incidental
damages. “Typical” parameters which may be provided in SCILLC data sheets and/or specifications can and do vary in different applications and actual
performance may vary over time. All operating parameters, including “Typicals” must be validated for each customer application by customer’s technical experts.
SCILLC does not convey any license under its patent rights nor the rights of others. SCILLC products are not designed, intended, or authorized for use as
components in systems intended for surgical implant into the body, or other applications intended to support or sustain life, or for any other application in which
the failure of the SCILLC product could create a situation where personal injury or death may occur. Should Buyer purchase or use SCILLC products for any
such unintended or unauthorized application, Buyer shall indemnify and hold SCILLC and its officers, employees, subsidiaries, affiliates, and distributors
harmless against all claims, costs, damages, and expenses, and reasonable attorney fees arising out of, directly or indirectly, any claim of personal injury or
death associated with such unintended or unauthorized use, even if such claim alleges that SCILLC was negligent regarding the design or manufacture of the
part. SCILLC is an Equal Opportunity/Affirmative Action Employer. This literature is subject to all applicable copyright laws and is not for resale in any manner.
http://onsemi.com
37