AA6400-AA6500-AA6600 Thermal Windows

AA™6400/6500/6600
6400/6500 Thermal
Thermal
Window
Window
The Comfort of Thermal Performance
and Condensation Resistance in a
Masterful Design
A window that keeps what’s on the outside out, while maintaining
occupant comfort on the inside is a valuable commodity. The
AA™6400/6500/6600 Thermal Window delivers superior thermal
and water performance and excellent condensation resistance while
meeting the unique challenges of northern climates. A fusion of
beauty, strength and functionality, the AA™6400/6500/6600 Thermal
Window enhances any application – new and retrofit construction –
while delivering architectural aesthetic appeal and ease of installation.
Ideal for new and retrofit construction, the AA™6400/6500/6600
Thermal Window enables the designer to leverage aesthetic options
while maintaining the thermal integrity of the exterior façade. By
employing high-performance polyamide thermal break technology,
the window meets or exceeds the highest performance levels set
forth by AAMA/WDMA/CSA 101/I.S.2/A440 (NAFS) for windows. With
outstanding water performance, condensation resistance and thermal
transmittance performance capabilities, the AA™6400/6500/6600
Thermal Window raises the standards for high-performing windows
by maintaining occupant comfort on the inside while keeping what’s
on the outside out.
Performance
Fabrication and Installation
The high-performing 4" (101.6 mm) deep AA™6400 Thermal Window,
5" (127 mm) deep AA™6500 Thermal Window and 6" (152.4 mm)
deep AA™6600 Thermal Window achieve a superb condensation
index (I value) and thermal transmittance (U-factor). The advanced
design provides the ability to interface with air and vapor barriers to
ensure the continuity of the seal at the window perimeter.
This window is perfect for punched and strip openings. A specially
designed coupling mullion allows the windows to be installed
in a multi-modular strip application. The framing systems can
accommodate both projected and casement vents. The project
out and outswing casement vents can also be installed into curtain
wall systems.
Additionally, the AA™6400/6500/6600 Thermal Window has a
pressure-equalized cavity and a rain screen design that deters
water infiltration. The window accommodates 1" (25 mm) or 1-3/4"
(44.5 mm) insulating glass units combined with a polyamide thermal
break for enhanced thermal performance. The structural aspects of
Thermal simulations show temperature the product are also enhanced
variations from exterior/cold side
through the polyamide thermal
to interior/warm side of AA™6400
break connecting the exterior
Thermal Window.
portion of the frame to the
interior portion. This technology
permits composite action,
thus achieving greater load
resistance while still offering
design flexibility. Additionally,
Casement swing
Fixed window
the “top hat” accent feature
out window
with 1" highof the AA™6500/6600 Thermal
with 1" highperformance
Window provides a deeper
performance
insulating glass
insulating glass
5" and 6" frame for thicker
wall construction and greater
structural capability.
The window is interior glazed, which allows for easy glazing and
reglazing in the field – an added benefit in cold climates.
Aesthetics and Design Options
Kawneer’s AA™6400/6500/6600 Thermal Window offers the versatility
in design and the high performance required for today‘s building
applications. Whether it is the overall flush appearance provided by
the AA™6400 Thermal Window with its extreme frontal placement of
glass or the distinctive “top hat” accent feature of the AA™6500/6600
Thermal Window, beauty never has to be sacrificed for functionality.
The operable vents have 45° mitered corners, which give the window
a smooth and attractive appearance. A dual color option offers the
flexibility to vary interior and exterior finishes, enabling designers
to coordinate and accent multiple environments. Stylish hardware
options include Euro-groove multipoint locking, roto operators, cam
handles, pole rings, access control locks and stainless steel 4-bar
hinges or concealed hinges.
Since the window is made from aluminum, it will never rot, warp
or buckle due to moisture and weather exposure. Because it
attains outstanding condensation resistance, the window is ideal
for healthcare and education applications where condensation and
mold are significant concerns. Superior thermal efficiency also
makes the window a good choice for buildings seeking Leadership
in Energy and Environmental Design certification with the U.S. and
Canadian green building councils.
Designed to perform above current North American testing
standards, the AA™6400/6500/6600 Thermal Window has been
fully tested and meets or exceeds the minimum requirements for
architectural window performance class, including lifecycle testing.
Performance Test Standards
Windows are tested in accordance with CSA A440 and AAMA/
WDMA/CSA 101/I.S.2/A440-08 (NAFS).
Air Infiltration
Water Structural – Uniform Wind Load Thermal Cycling Thermal Transmittance – U-Factor
Condensation Resistance (CRF, I, CR) Solar Heat Gain Coefficient (SHGC),
Visible Transmittance (VT)
Sound Transmission (STC, OITC) ASTM E283
ASTM E331, E547
ASTM E330
AAMA 501.5
AAMA 1503, 507; NFRC 100
AAMA 1503; CSA A440.2; NFRC 500
AAMA 507; NFRC 200
ASTM E90, E1425; AAMA 1801
*Test results available from Kawneer.
Contact your Kawneer sales representative for more information.
Kawneer Company, Inc.
Technology Park / Atlanta
555 Guthridge Court
Norcross, GA 30092
kawneer.com
kawneergreen.com
770 . 449 . 5555
© Kawneer Company, Inc. 2014 LITHO IN U.S.A. Form No. 13-2174-2
AA™ is a trademark of Kawneer Company, Inc. and Alcoa Inc.
The AA™6400 Thermal Window
features a flush appearance.
The AA™6500 Thermal Window
with “top hat” accent feature
provides added strength and
interest to the sightline.
MAY, 2016
AATM 6400/6500/6600 Thermal Window
EC 97911-097
INDEX
FIXED WINDOW................................................................................ 3-4
AATM6400 FIXED 4" WINDOW...................................................... 5-6
AATM6500 FIXED 5" WINDOW...................................................... 7-8
AATM6600 FIXED 6" WINDOW.................................................... 9-10
PROJECT-IN WINDOW................................................................. 11-14
PROJECT-OUT WINDOW............................................................. 15-18
INSWING CASEMENT WINDOW.................................................. 19-22
OUTSWING CASEMENT WINDOW.............................................. 23-26
MISCELLANEOUS DETAILS............................................................. 27
WIND LOAD CHARTS................................................................... 28-32
DEADLOAD CHARTS................................................................... 33-34
THERMAL CHARTS...................................................................... 35-53
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
LAWS AND BUILDING AND SAFETY CODES GOVERNING THE DESIGN AND USE OF GLAZED ENTRANCE,
WINDOW, AND CURTAIN WALL PRODUCTS VARY WIDELY. KAWNEER DOES NOT CONTROL THE
SELECTION OF PRODUCT CONFIGURATIONS, OPERATING HARDWARE, OR GLAZING MATERIALS,
AND ASSUMES NO RESPONSIBILITY THEREFOR.
Metric (SI) conversion figures are included throughout these details for reference. Numbers in parentheses
(
) are millimeters unless otherwise noted.
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
1
The following metric (SI ) units are found in these details:
m –meter
cm – centimeter
mm –millimeter
s –second
Pa –pascal
MPa –megapascal
Kawneer reserves the right to change configurations without prior notice when deemed necessary for product
improvement.
kawneer.com
ADME130EN
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
AATM 6400/6500/6600 Thermal Window
BLANK PAGE
ADME130EN
kawneer.com
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
2
EC 97911-097
MAY, 2016
AATM 6400/6500/6600 Thermal Window
MAY, 2016
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
EC 97911-097
FIXED WINDOW
Features
• Architectural Grade Commercial Window
• Tested to US and Canadian Standards
• Polyamide Thermal Break
• Tubular Profiles
• Optional "Top Hat" Accent Feature
• Rain Screen and Pressure Equalized
• Accommodates Air and / or Vapor barrier
• Accommodates Projected and Casement Vents
• Field Dry Glazed
• 1" dual glazing (RSPE with gasket)
• 1-3/4" triple glazing (RSPE with silicone heel bead)
• Interior Applied Glazing Bead
• Architectural Anodized Finishes and Applied Coatings
• Interior and Exterior Dual Finish Options
• Two Year Manufacturer’s Warranty
Exterior
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
Thermal Break
Fixed Window
For specific product applications,
Consult your Kawneer representative.
kawneer.com
ADME130EN
Interior
3
FIXED WINDOW
CLASS and GRADE
Architectural Window Grade AW-PG70-FW
TESTING STANDARD
AAMA / WDMA / CSA / 101 / I.S.2 / A440 (NAFS)
FRAME DEPTH
4" (AATM6400), 5" (AATM6500), or 6" (AATM6600)
TYPICAL WALL THICKNESS
.070" Nominal Frame
INFILL OPTIONS
1" or 1-3/4"
STANDARD HARDWARE
Not Applicable
OPTIONAL HARDWARE
Not Applicable
OTHER OPTIONS
Expansion Mullions
ADME130EN
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
AATM 6400/6500/6600 Thermal Window
kawneer.com
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
4
EC 97911-097
MAY, 2016
© Kawneer Company, Inc., 2014
3/8" (10)
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
kawneer.com
3/8" (10)
1-3/4" (45)
W.D.
4A
JAMB
D.L.O
3/8" (10)
1-3/4" (45)
O.D.
D.L.O
D.L.O
4
JAMB
ADME130EN
2
INTERMEDIATE
HORIZONTAL
3
TYPICAL ELEVATION
Log onto www.kawneer.com for other configurations
3
SILL
1-5/16" (33)
W.D.
2-5/8" (67)
W.D.
O.D.
O.D.
5
TUBULAR
MULLION
D.L.O
1-5/16" (33)
4A
1-5/16" (33)
D.L.O
6
2-5/8" (67)
5
D.L.O
2
D.L.O
1-3/4" (45)
1
HEAD
D.L.O
4
O.D.
1
W.D.
MAX. 18' 0"
1-3/4" (45)
O.D.
OVERALL FRAME WIDTH
W.D.
3/8" (10)
EC 97911-097
W.D.
O.D.
OVERALL FRAME HEIGHT
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
MAY, 2016
AATM 6400/6500/6600 Thermal Window
D.L.O
W.D.
O.D.
6
JAMB
5
AATM6400 FIXED 4" WINDOW
SCALE : 3" = 1'-0"
(Nominal Dimensions Shown)
1-5/16" (33)
1-3/4" (45)
3/8" (10)
3/8" (10)
1-3/4" (45)
W.D.
4A
JAMB
D.L.O
2
INTERMEDIATE
HORIZONTAL
3
SILL
1-5/16" (33)
3/8" (10)
1-3/4" (45)
O.D.
4
JAMB
D.L.O
D.L.O
2-5/8" (67)
1-5/16" (33)
ADME130EN
D.L.O
D.L.O
4A
3/8" (10)
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
1-5/16" (33)
1-3/4" (45)
W.D.
D.L.O
AATM6400 FIXED 4" WINDOW
1-17/32" (39)
1-17/32" (39)
W.D.
W.D.
3-1/16" (78)
W.D.
D.L.O
O.D.
O.D.
O.D.
5
TUBULAR
MULLION
6
MULTI-MODULAR
COUPLING MULLION
kawneer.com
© Kawneer Company, Inc., 2014
3
D.L.O
6
1-5/16" (33)
5
W.D.
2
2-5/8" (67)
4
D.L.O
1
1
HEAD
D.L.O
MAX. 18' 0"
W.D.
O.D.
OVERALL FRAME WIDTH
1-3/4" (45)
O.D.
AATM 6400/6500/6600 Thermal Window
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
3/8" (10)
O.D.
OVERALL FRAME HEIGHT
6
EC 97911-097
MAY, 2016
SCALE : 3" = 1'-0"
(Nominal Dimensions Shown)
TYPICAL ELEVATION
Log onto www.kawneer.com for other configurations
© Kawneer Company, Inc., 2014
3/8" (10)
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
kawneer.com
1-3/4" (45)
3/8" (10)
W.D.
4A
JAMB
D.L.O
1-3/4" (45)
3/8" (10)
O.D.
D.L.O
D.L.O
4
JAMB
ADME130EN
2
INTERMEDIATE
HORIZONTAL
3
TYPICAL ELEVATION
Log onto www.kawneer.com for other configurations
3
SILL
1-5/16" (33)
2-5/8" (67)
W.D.
W.D.
O.D.
O.D.
5
TUBULAR
MULLION
D.L.O
1-5/16" (33)
4A
1-5/16 (33)"
D.L.O
6
2-5/8" (67)
5
D.L.O
2
D.L.O
1-3/4" (45)
1
HEAD
D.L.O
4
O.D.
1
W.D.
MAX. 18' 0"
1-3/4" (45)
O.D.
OVERALL FRAME WIDTH
W.D.
3/8" (10)
EC 97911-097
W.D.
O.D.
OVERALL FRAME HEIGHT
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
MAY, 2016
AATM 6400/6500/6600 Thermal Window
D.L.O
W.D.
O.D.
6
JAMB
7
AATM6500 FIXED 5" WINDOW
SCALE : 3" = 1'-0"
(Nominal Dimensions Shown)
1-5/16" (33)
1-3/4" (45)
3/8" (10)
1-3/4" (45)
3/8" (10)
W.D.
4A
JAMB
D.L.O
1-3/4" (45)
3/8" (10)
O.D.
4
JAMB
D.L.O
D.L.O
1-5/16" (33)
2-5/8" (67)
1-5/16" (33)
ADME130EN
D.L.O
TYPICAL ELEVATION
Log onto www.kawneer.com for other configurations
3
SILL
3
D.L.O
1-3/4" (45)
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
D.L.O
W.D.
3/8" (10)
AATM6500 FIXED 5" WINDOW
1-17/32" (39)
3 1/16" (78)
1-17/32" (39)
D.L.O
W.D.
W.D.
W.D.
O.D.
O.D.
O.D.
5
TUBULAR
MULLION
6
MULTI-MODULAR
COUPLING MULLION
kawneer.com
© Kawneer Company, Inc., 2014
2
INTERMEDIATE
HORIZONTAL
1-5/16" (33)
D.L.O
6
2-5/8" (67)
5
D.L.O
4A
1-5/16 (33)"
2
1
HEAD
D.L.O
4
O.D.
1
1-3/4" (45)
O.D.
MAX. 18' 0"
W.D.
OVERALL FRAME WIDTH
W.D.
O.D.
AATM 6400/6500/6600 Thermal Window
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
3/8" (10)
OVERALL FRAME HEIGHT
8
EC 97911-097
MAY, 2016
SCALE : 3" = 1'-0"
(Nominal Dimensions Shown)
© Kawneer Company, Inc., 2014
3/8" (10)
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
kawneer.com
3/8" (10)
1-3/4" (45)
W.D.
4A
JAMB
TYPICAL ELEVATION
Log onto www.kawneer.com for other configurations
1-5/16" (33)
D.L.O
3/8" (10)
1-3/4" (45)
O.D.
W.D.
D.L.O
D.L.O
4
JAMB
ADME130EN
2-5/8" (67)
W.D.
O.D.
O.D.
5
TUBULAR
MULLION
6
2
INTERMEDIATE
HORIZONTAL
3
SILL
D.L.O
1-5/16 (33)"
4A
1-5/16" (33)
D.L.O
1-3/4" (45)
W.D.
D.L.O
1
2-5/8" (67)
W.D.
5
D.L.O
1
HEAD
D.L.O
MAX. 18' 0"
O.D.
OVERALL FRAME WIDTH
W.D.
2
O.D.
3/8" (10)
EC 97911-097
1-3/4" (45)
4
O.D.
OVERALL FRAME HEIGHT
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
MAY, 2016
AATM 6400/6500/6600 Thermal Window
D.L.O
W.D.
O.D.
6
JAMB
9
AATM6600 FIXED 6" WINDOW
SCALE : 3" = 1'-0"
(Nominal Dimensions Shown)
3
1-5/16" (33)
1-3/4" (45)
3/8" (10)
1-3/4" (45)
3/8" (10)
W.D.
4A
JAMB
TYPICAL ELEVATION
Log onto www.kawneer.com for other configurations
D.L.O
1-3/4" (45)
O.D.
3/8" (10)
4
JAMB
D.L.O
2
INTERMEDIATE
HORIZONTAL
3
SILL
1-5/16" (33)
1-5/16" (33)
D.L.O
D.L.O
2-5/8" (67)
ADME130EN
6
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
1-5/16" (33)
1-3/4" (45)
W.D.
D.L.O
3/8" (10)
AATM6500 FIXED 6" WINDOW
1-17/32" (39)
D.L.O
1-17/32" (39)
3 1/16" (78)
D.L.O
W.D.
W.D.
W.D.
O.D.
O.D.
O.D.
5
TUBULAR
MULLION
6
MULTI-MODULAR
COUPLING MULLION
kawneer.com
© Kawneer Company, Inc., 2014
3
1-5/16 (33)"
D.L.O
5
W.D.
4A
2-5/8" (67)
2
D.L.O
4
1
HEAD
D.L.O
1
W.D.
O.D.
MAX. 18' 0"
1-3/4" (45)
O.D.
AATM 6400/6500/6600 Thermal Window
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
3/8" (10)
O.D.
OVERALL FRAME HEIGHT
10
EC 97911-097
MAY, 2016
SCALE : 3" = 1'-0"
(Nominal Dimensions Shown)
OVERALL FRAME WIDTH
AATM 6400/6500/6600 Thermal Window
MAY, 2016
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
EC 97911-097
PROJECT-IN WINDOW
Features
• Architectural Grade Commercial Window
• Tested to US and Canadian Standards
• Polyamide Thermal Break
• Accentuated Tubular Profiles
• Field Dry Glazed
• 1" dual glazing (RSPE with gasket)
• 1-3/4" triple glazing (RSPE with silicone heel bead)
• Adjustable EURO-Groove Mounted Hardware
• Single Handle Multi-Point Locking
• Interior Applied Glazing Bead
• Architectural Anodized Finishes and Applied Coatings
• Interior and Exterior Dual Finish Options
• Two Year Manufacturer’s Warranty
Exterior
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
Thermal Break
Project-in Window
For specific product applications,
Consult your Kawneer representative.
kawneer.com
ADME130EN
Interior
11
AATM 6400/6500/6600 Thermal Window
MAY, 2016
EC 97911-097
Architectural Window Grade AW-PG70-AP
TESTING STANDARD
AAMA / WDMA / CSA / 101 / I.S.2 / A440 (NAFS)
FIXED FRAMING DEPTH
4" (AATM6400), 5" (AATM6500), or 6" (AATM6600)
VENT DEPTH
3-9/16"
TYPICAL WALL THICKNESS
.070" Nominal Frame / .070" Nominal Vent
TYPICAL MAX. SIZE
(Sizes are for fixed frame D.L.O.)
60" x 36"
TYPICAL MIN. SIZE
(Sizes are for fixed frame D.L.O.)
18" x 22"
INFILL OPTIONS
1" or 1-3/4"
STANDARD HARDWARE
Stainless Steel 4-Bar Hinges
Single Handle Multi-Point Locking
OPTIONAL HARDWARE
Single Keyed Handle Multi-Point Locking
Limit Stop
OTHER OPTIONS
Insect Screens
ADME130EN
kawneer.com
© Kawneer Company, Inc., 2014
CLASS and GRADE
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
PROJECT-IN WINDOW
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
12
© Kawneer Company, Inc., 2014
3/8" (10)
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
3/8" (10)
kawneer.com
TYPICAL ELEVATION
Log onto www.kawneer.com for other configurations
1-3/4" (45) 1-3/4" (45)
D.L.O
O.D.
W.D.
3
VENT
JAMB
ADME130EN
D.L.O
3
AATM6400 details shown, AATM6500 and AATM6600
shown dotted in.
D.L.O
1-3/4" (45)
W.D.
4
D.L.O
2
VENT
SILL
W.D.
O.D.
4
VENT
JAMB
2-5/8" (67)
W.D.
1-5/16" (33)
1
VENT
HEAD
1-5/16" (33)
2-5/8" (67)
1-5/16" (33)
1-3/4" (45)
EC 97911-097
1-3/4" (45) 1-3/4" (45)
O.D.
1
O.D.
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
MAY, 2016
AATM 6400/6500/6600 Thermal Window
PROJECT-IN WINDOW
SCALE : 3" = 1'-0"
(Nominal Dimensions Shown)
2
3-9/16" (90.5)
4" (AA6400)
5" (AA6500)
6" (AA6600)
1-5/16" (33)
D.L.O
13
AATM 6400/6500/6600 Thermal Window
MAY, 2016
EC 97911-097
A standard hinge for ventilators providing approximately
45° to 60° openings depending on size. An optional limit
stop is available to restrict hinge travel and limit vent
opening.
MULTI-POINT LOCKING
Single handle multi-point locking is standard providing
any number of concealed EURO-Groove mounted
locking points around the ventilator perimeter. Stylish
handles are available in a silver painted finish.
MULTI-POINT LOCKING
- KEYED
Single keyed handle multi-point locking providing any
number of concealed EURO-Groove mounted locking
points around the ventilator perimeter. Stylish handles
are available in a silver painted finish.
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
STAINLESS STEEL
4 BAR HINGES
ADME130EN
kawneer.com
© Kawneer Company, Inc., 2014
PROJECT-IN WINDOW
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
14
AATM 6400/6500/6600 Thermal Window
MAY, 2016
PROJECT-OUT WINDOW
Features
• Architectural Grade Commercial Window
• Tested to US and Canadian Standards
• Polyamide Thermal Break
• Accentuated Tubular Profiles
• Field Dry Glazed
• 1" dual glazing (RSPE with gasket)
• 1-3/4" triple glazing (RSPE with silicone heel bead)
• Adjustable EURO-Groove Mounted Hardware
• Dual Handle Multi-Point Locking
• Interior Applied Glazing Bead
• Architectural Anodized Finishes and Applied Coatings
• Interior and Exterior Dual Finish Options
• Two Year Manufacturer’s Warranty
• Compatible with Curtain Wall Systems
Thermal Break
Exterior
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
EC 97911-097
Project-out Window
For specific product applications,
Consult your Kawneer representative.
kawneer.com
ADME130EN
Interior
15
AATM 6400/6500/6600 Thermal Window
MAY, 2016
EC 97911-097
Architectural Window Grade AW-PG70-AP
TESTING STANDARD
AAMA / WDMA / CSA / 101 / I.S.2 / A440 (NAFS)
FIXED FRAMING DEPTH
4" (AATM6400), 5" (AATM6500), or 6" (AATM6600)
VENT / VENT FRAME DEPTH
3-3/8"
TYPICAL WALL THICKNESS
.070" Nominal Frame / .070" Nominal Vent
TYPICAL MAX. SIZE
(Sizes are for fixed frame D.L.O.)
60" x 36"
TYPICAL MIN. SIZE
(Sizes are for fixed frame D.L.O.)
28" x 20"
INFILL OPTIONS
1" or 1-3/4"
STANDARD HARDWARE
Stainless Steel 4-Bar Hinges
Dual Handle Multi-Point Locking
Pivot Shoe Roto
OPTIONAL HARDWARE
Dual Handle Multi-Point Locking - Keyed
Cam Handles
Access Control Locks
Pole and Hanger
OTHER OPTIONS
Insect Screens
ADME130EN
kawneer.com
© Kawneer Company, Inc., 2014
CLASS and GRADE
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
PROJECT-OUT WINDOW
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
16
© Kawneer Company, Inc., 2014
3/8" (10)
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
TYPICAL ELEVATION
Log onto www.kawneer.com for other configurations
TM
AA 6400 details shown, AA 6500 and AA 6600
shown dotted in.
kawneer.com
TM
1-3/4" (45)
3/8" (10)
2-7/8" (73)
TM
W.D.
D.L.O
O.D.
3
VENT
JAMB
ADME130EN
2
VENT
SILL
D.L.O
1-3/4" (45)
W.D.
2
D.L.O
4
D.L.O
1
W.D.
2-5/8" (67)
1
VENT
HEAD
2-7/8" (73)
W.D.
O.D.
4
VENT
JAMB
1-5/16" (93)
2-7/8" (73)
O.D.
D.L.O
1-5/16" (33)
EC 97911-097
2-7/8" (73)
3
O.D.
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
MAY, 2016
AATM 6400/6500/6600 Thermal Window
PROJECT-OUT WINDOW
SCALE : 3" = 1'-0"
(Nominal Dimensions Shown)
3-3/8" (85.7)
4" (AA6400)
5" (AA6500)
6" (AA6600)
1-5/16" (33)
2-5/8" (67)
1-5/16" (33)
D.L.O
17
AATM 6400/6500/6600 Thermal Window
MAY, 2016
EC 97911-097
A standard hinge for ventilators providing a 4" opening to
comply with child safety requirements.
MULTI-POINT LOCKING
Single handle multi-point locking is standard providing
any number of concealed EURO-Groove mounted
locking points around the ventilator perimeter. Stylish
handles are available in a silver painted finish.
MULTI-POINT LOCKING
- KEYED
Single keyed handle multi-point locking providing any
number of concealed EURO-Groove mounted locking
points around the ventilator perimeter. Stylish handles
are available in a silver painted finish.
PIVOT-SHOE
ROTO-OPERATOR
Pivot shoe roto operator is located on the center line
of the bottom horizontal frame. Standard finish shall be
painted silver.
STANDARD
CAM HANDLE
Cast white bronze cam handles are standard for the
manual operation and locking of ventilators.
CAM HANDLE
WITH POLE RING
Cast white bronze cam handles with pole ring provide
manual operation of ventilators located above reach.
These handles are operated with a sash pole.
POLE RING
Cast white bronze pole ring is used in conjunction with
locking hardware for sash pole operation of ventilators.
SASH POLE
A 3/4" diameter aluminum sash pole with a cast
white bronze pull down hook and black rubber tip.
Available in 6 ft. and 12 ft. lengths with optional
cast white bronze Pole Hanger.
HANGER
FOR SASH POLE
ACCESS CONTROL
LOCK
In lieu of cam handles cast white bronze access control
locks are offered for managed control of vent operations.
Lock is operated with a manganese bronze removable
handle.
ADME130EN
kawneer.com
© Kawneer Company, Inc., 2014
STAINLESS STEEL
4 BAR HINGES
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
PROJECT-OUT WINDOW
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
18
MAY, 2016
AATM 6400/6500/6600 Thermal Window
INSWING CASEMENT WINDOW
Features
• Architectural Grade Commercial Window
• Tested to US and Canadian Standards
• Polyamide Thermal Break
• Accentuated Tubular Profiles
• Field Dry Glazed
• 1" dual glazing (RSPE with gasket)
• 1-3/4" triple glazing (RSPE with silicone heel bead)
• Adjustable EURO-Groove Mounted Hardware
• Single Handle Multi-Point Locking
• Interior Applied Glazing Bead
• Architectural Anodized Finishes and Applied Coatings
• Interior and Exterior Dual Finish Options
• Two Year Manufacturer’s Warranty
Thermal Break
Interior
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
EC 97911-097
Exterior
HINGED
LEFT
Inswing Casement Window
For specific product applications,
Consult your Kawneer representative.
kawneer.com
ADME130EN
19
AATM 6400/6500/6600 Thermal Window
MAY, 2016
EC 97911-097
Architectural Window Grade AW-PG70-C
TESTING STANDARD
AAMA / WDMA / CSA / 101 / I.S.2 / A440 (NAFS)
FRAME DEPTH
4" (AATM6400), 5" (AATM6500), or 6" (AATM6600)
VENT DEPTH
3-9/16"
TYPICAL WALL THICKNESS
.070" Nominal Frame / .070" Nominal Vent
TYPICAL MAX. SIZE
(Sizes are for fixed frame D.L.O.)
36" x 60"
TYPICAL MIN. SIZE
(Sizes are for fixed frame D.L.O.)
22" x 22"
INFILL OPTIONS
1" or 1-3/4"
STANDARD HARDWARE
Stainless Steel 4-Bar Hinges
Single Handle Multi-Point Locking
OPTIONAL HARDWARE
Single Keyed Handle Multi-Point Locking
Limit Stop
OTHER OPTIONS
Insect Screens
ADME130EN
kawneer.com
© Kawneer Company, Inc., 2014
CLASS and GRADE
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
INSWING CASEMENT WINDOW
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
20
© Kawneer Company, Inc., 2014
kawneer.com
2
3/8" (10)
2
VENT
SILL
1-3/4" (45) 1-3/4" (45)
W.D.
D.L.O
D.L.O
O.D.
3
VENT
JAMB
ADME130EN
D.L.O
HINGED
LEFT
W.D.
3
AATM6400 details shown, AATM6500 and AATM6600
shown dotted in.
3/8" (10)
O.D.
4
D.L.O
3/8" (10)
1
1
VENT
HEAD
TYPICAL ELEVATION
Log onto www.kawneer.com for other configurations
1-3/4" (45)
1-3/4" (45) 1-3/4" (45)
W.D.
O.D.
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
EC 97911-097
1-3/4" (45) 1-3/4" (45)
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
MAY, 2016
AATM 6400/6500/6600 Thermal Window
INSWING CASEMENT WINDOW
SCALE : 3" = 1'-0"
(Nominal Dimensions Shown)
3-9/16" (90.5)
4" (AA6400)
5" (AA6500)
6" (AA6600)
1-5/16" (33)
1-5/16" (33)
W.D.
2-5/8" (67)
O.D.
4
VENT
JAMB
D.L.O
21
AATM 6400/6500/6600 Thermal Window
MAY, 2016
EC 97911-097
A standard hinge for ventilators providing up to 45° of
open. An optional limit stop is available to restrict hinge
travel and limit vent opening.
MULTI-POINT LOCKING
Single handle multi-point locking is standard providing
any number of concealed EURO-Groove mounted
locking points around the ventilator perimeter. Stylish
handles are available in a silver painted finish.
MULTI-POINT LOCKING
- KEYED
Single keyed handle multi-point locking providing any
number of concealed EURO-Groove mounted locking
points around the ventilator perimeter. Stylish handles
are available in a silver painted finish.
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
STAINLESS STEEL
4 BAR HINGES
ADME130EN
kawneer.com
© Kawneer Company, Inc., 2014
INSWING CASEMENT WINDOW
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
22
MAY, 2016
AATM 6400/6500/6600 Thermal Window
OUTSWING CASEMENT WINDOW
Features
• Architectural Grade Commercial Window
• Tested to US and Canadian Standards
• Polyamide Thermal Break
• Accentuated Tubular Profiles
• Field Dry Glazed
• 1" dual glazing (RSPE with gasket)
• 1-3/4" triple glazing (RSPE with silicone heel bead)
• Adjustable EURO-Groove Mounted Hardware
• Single Handle Multi-Point Locking
• Interior Applied Glazing Bead
• Architectural Anodized Finishes and Applied Coatings
• Interior and Exterior Dual Finish Options
• Two Year Manufacturer’s Warranty
• Compatible with Curtain Wall Systems
Interior
Exterior
HINGED
LEFT
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
EC 97911-097
Outswing Casement Window
Thermal Break
For specific product applications,
Consult your Kawneer representative.
kawneer.com
ADME130EN
23
AATM 6400/6500/6600 Thermal Window
MAY, 2016
EC 97911-097
Architectural Window Grade AW-PG70-C
TESTING STANDARD
AAMA / WDMA / CSA / 101 / I.S.2 / A440 (NAFS)
FIXED FRAMING DEPTH
4" (AATM6400), 5" (AATM6500), or 6" (AATM6600)
VENT / VENT FRAME DEPTH
3-3/8"
TYPICAL WALL THICKNESS
.070" Nominal Frame / .070" Nominal Vent
TYPICAL MAX. SIZE
(Sizes are for fixed frame D.L.O.)
36" x 60"
TYPICAL MIN. SIZE
(Sizes are for fixed frame D.L.O.)
18" x 18"
INFILL OPTIONS
1" or 1-3/4"
STANDARD HARDWARE
Concealed Hinge
Single Handle Multi-Point Locking
Roto Operator
OPTIONAL HARDWARE
Single Keyed Handle Multi-Point Locking
Cam Handles
4-bar Hinges
Pole and Hanger
OTHER OPTIONS
Insect Screens
ADME130EN
kawneer.com
© Kawneer Company, Inc., 2014
CLASS and GRADE
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
OUTSWING CASEMENT WINDOW
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
24
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
kawneer.com
TYPICAL ELEVATION
Log onto www.kawneer.com for other configurations
AATM6400 details shown, AATM6500 and AATM6600
shown dotted in.
1-3/4" (45)
3/8" (10)
2-7/8" (73)
D.L.O
W.D.
O.D.
3
VENT
JAMB
ADME130EN
1-3/4" (45)
2
VENT
SILL
2
D.L.O
D.L.O
D.L.O
W.D.
1-3/4" (45)
1
VENT
HEAD
2-7/8" (73)
W.D.
O.D.
4
VENT
JAMB
2-7/8" (73)
1
W.D.
O.D.
3/8" (10)
EC 97911-097
2-7/8" (73)
HINGED
LEFT
3/8" (10)
3
O.D.
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
MAY, 2016
AATM 6400/6500/6600 Thermal Window
OUTSWING CASEMENT WINDOW
SCALE : 3" = 1'-0"
(Nominal Dimensions Shown)
4
3-3/8" (85.7)
4" (AA6400)
5" (AA6500)
6" (AA6600)
1-5/16" (33)
2-5/8" (67)
1-5/16" (33)
D.L.O
25
AATM 6400/6500/6600 Thermal Window
MAY, 2016
EC 97911-097
A standard hinge for outswing ventilators.
MULTI-POINT LOCKING
Single handle multi-point locking is standard providing
any number of concealed EURO-Groove mounted
locking points around the ventilator perimeter. Stylish
handles are available in a silver painted finish.
MULTI-POINT LOCKING
- KEYED
Single keyed handle multi-point locking providing any
number of concealed EURO-Groove mounted locking
points around the ventilator perimeter. Stylish handles
are available in a silver painted finish.
ROTO-OPERATOR
Roto operator is located on the bottom horizontal
vent-frame. Standard finish shall be painted silver.
STANDARD
CAM HANDLE
Cast white bronze cam handles are standard for the
manual operation and locking of ventilators.
CAM HANDLE
WITH POLE RING
Cast white bronze cam handles with pole ring provide
manual operation of ventilators located above reach.
These handles are operated with a sash pole.
SASH POLE
A 3/4" diameter aluminum sash pole with a cast
white bronze pull down hook and black rubber tip.
Available in 6 ft. and 12 ft. lengths with optional
cast white bronze Pole Hanger.
HANGER
FOR SASH POLE
ACCESS CONTROL
LOCK
In lieu of cam handles cast white bronze access control
locks are offered for managed control of vent operations.
Lock is operated with a manganese bronze removable
handle.
KEYED LIMIT ARM
Key released limit arms may be used to restrict ventilator
opening when used with cam handles or access control
locks.
ADME130EN
kawneer.com
© Kawneer Company, Inc., 2014
CONCEALED
HINGES
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
OUTSWING CASEMENT WINDOW
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
26
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
MAY, 2016
kawneer.com
AATM 6400/6500/6600 Thermal Window
EC 97911-097
MISCELLANEOUS
SCALE : 3" = 1'-0"
(Nominal Dimensions Shown)
TRIM DETAILS
TRIPLE GLAZED HEAD
HEAD
ANCHORS
SILL
CURTAIN WALL ADAPTERS
TYPICAL SILL EXTENSION
FLANGE LEG FRAME
1600UT SYSTEMTM 1 CURTAIN WALL
(Project-Out/Outswing Casement)
HEAD RECEPTOR
1600UT SYSTEMTM 1 CURTAIN WALL
(Project-In/Inswing Casement)
ADME130EN
27
28
AATM 6400/6500/6600 Thermal Window
WIND LOAD / DEADLOAD CHARTS
MAY, 2016
EC 97911-097
DEADLOAD CHARTS
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
Horizontal or deadload limitations are based upon 1/16" (1.6) at operable vents or 1/8" (3.2) at fixed openings, maximum
allowable deflection at the center of an intermediate horizontal member. The accompanying charts are calculated for 1"
(25.4) thick insulating glass supported on two setting blocks placed at the loading points shown.
ADME130EN
kawneer.com
© Kawneer Company, Inc., 2014
Mullions are designed for deflection limitations in accordance with AAMA TIR-A11 of L/175 up to 13'-6" and L/240 +1/4"
above 13'-6". These curves are for mullions WITH HORIZONTALS and are based on engineering calculations for stress
and deflection. Allowable wind load stress for ALUMINUM 15,152 psi (104MPa), STEEL 30,000 psi (207MPa). Charted
curves, in all cases are for the limiting value. Wind load charts contained herein are based upon nominal wind load
utilized in allowable stress design. A conversion from Load Resistance Factor Design (LRFD) is provided. To convert
ultimate wind loads to nominal loads, multiply ultimate wind loads by a factor of 0.6 per ASCE/SEI 7. A 4/3 increase in
allowable stress has not been used to develop these curves. For special situations not covered by these curves, contact
your Kawneer representative for additional information.
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
WIND LOAD CHARTS
AATM 6400/6500/6600 Thermal Window
MAY, 2016
WIND LOAD CHARTS
A=
B=
C=
D=
E=
LRFD Ultimate
Design Load
33 PSF (1580)
50 PSF (2400)
67 PSF (3200)
83 PSF (4000)
117 PSF (5580)
MULLION CENTERS IN METERS
1.0
1.0
10
3.0
9
8
8
2.0
6
A
5
B
C
D1.0
E
4
3
2
MULLION HEIGHT IN FEET
7
MULLION HEIGHT IN METERS
9
423505
1
1
2
3
4
5
MULLION CENTERS IN FEET
2.0
B
C
D
E
6
5
4
1.0
3
2
1
WIND LOAD CHARTS ARE BASED ON
COMPOSITE PROPERTIES WHICH
ARE CALCULATED IN ACCORDANCE
WITH AAMA TIR-8 AND AAMA 505
6
A
7
0
0
1
2
5
6
MULLION CENTERS IN FEET
UNITS WITHOUT HORIZONTALS
MULLION CENTERS IN METERS
MULLION CENTERS IN METERS
1.0
1.0
10
3.0
7
2.0
A
6
5
B
4
C
D1.0
E
3
2
1
MULLION HEIGHT IN FEET
8
0
3.0
9
MULLION HEIGHT IN METERS
9
MULLION HEIGHT IN FEET
4
UNITS WITH HORIZONTALS
10
© Kawneer Company, Inc., 2014
3
1
2
3
4
5
6
MULLION CENTERS IN FEET
UNITS WITH HORIZONTALS
kawneer.com
7
B
2.0
6
C
D
E
5
4
1.0
3
2
423513
0
A
8
WIND LOAD CHARTS ARE BASED ON
COMPOSITE PROPERTIES WHICH
ARE CALCULATED IN ACCORDANCE
WITH AAMA TIR-8 AND AAMA 505
ADME130EN
1
0
0
1
2
3
4
5
6
MULLION CENTERS IN FEET
UNITS WITHOUT HORIZONTALS
MULLION HEIGHT IN METERS
0
3.0
MULLION HEIGHT IN METERS
10
0
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
Allowable Stress
Design Load
20 PSF (960)
30 PSF (1440)
40 PSF (1920)
50 PSF (2400)
70 PSF (3350)
MULLION CENTERS IN METERS
MULLION HEIGHT IN FEET
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
EC 97911-097
29
AATM 6400/6500/6600 Thermal Window
MAY, 2016
WIND LOAD CHARTS
EC 97911-097
LRFD Ultimate
Design Load
33 PSF (1580)
50 PSF (2400)
67 PSF (3200)
83 PSF (4000)
117 PSF (5580)
MULLION CENTERS IN METERS
MULLION CENTERS IN METERS
1.0
1.0
10
10
3.0
A
7
2.0
6
B
5
C
D
E1.0
4
3
2
423522
1
0
1
2
3
4
5
6
MULLION CENTERS IN FEET
WIND LOAD CHARTS ARE BASED ON
COMPOSITE PROPERTIES WHICH
ARE CALCULATED IN ACCORDANCE
WITH AAMA TIR-8 AND AAMA 505
UNITS WITH HORIZONTALS
8
B
7
6
2.0
C
D
5
E
4
1.0
3
2
1
0
0
1
2
3
4
5
6
MULLION CENTERS IN FEET
UNITS WITHOUT HORIZONTALS
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
0
MULLION HEIGHT IN FEET
8
MULLION HEIGHT IN METERS
9
MULLION HEIGHT IN METERS
MULLION HEIGHT IN FEET
9
3.0
A
ADME130EN
kawneer.com
© Kawneer Company, Inc., 2014
A=
B=
C=
D=
E=
Allowable Stress
Design Load
20 PSF (960)
30 PSF (1440)
40 PSF (1920)
50 PSF (2400)
70 PSF (3350)
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
30
AATM 6400/6500/6600 Thermal Window
MAY, 2016
WIND LOAD CHARTS
A=
B=
C=
D=
E=
LRFD Ultimate
Design Load
33 PSF (1580)
50 PSF (2400)
67 PSF (3200)
83 PSF (4000)
117 PSF (5580)
MULLION CENTERS IN METERS
1.0
10
3.0
3.0
9
A
7
B2.0
6
C
5
D
4
E
1.0
3
2
MULLION HEIGHT IN FEET
8
MULLION HEIGHT IN METERS
9
1
2
3
4
5
MULLION CENTERS IN FEET
5
4
1.0
3
1
WIND LOAD CHARTS ARE BASED ON
COMPOSITE PROPERTIES WHICH
ARE CALCULATED IN ACCORDANCE
WITH AAMA TIR-8 AND AAMA 505
6
6
0
0
1
2
5
6
MULLION CENTERS IN FEET
UNITS WITHOUT HORIZONTALS
MULLION CENTERS IN METERS
MULLION CENTERS IN METERS
1.0
1.0
10
3.0
9
B
7
2.0
C
D
6
5
E
4
1.0
3
2
MULLION HEIGHT IN FEET
8
1
0
3.0
A
9
A
MULLION HEIGHT IN METERS
MULLION HEIGHT IN FEET
4
UNITS WITH HORIZONTALS
10
© Kawneer Company, Inc., 2014
3
B
C
D2.0
E
8
7
6
5
4
1.0
3
2
1
423514
0
1
2
3
4
5
6
MULLION CENTERS IN FEET
UNITS WITH HORIZONTALS
kawneer.com
WIND LOAD CHARTS ARE BASED ON
COMPOSITE PROPERTIES WHICH
ARE CALCULATED IN ACCORDANCE
WITH AAMA TIR-8 AND AAMA 505
ADME130EN
0
0
1
2
3
4
5
6
MULLION CENTERS IN FEET
UNITS WITHOUT HORIZONTALS
MULLION HEIGHT IN METERS
0
B
C2.0
D
E
7
2
423504
1
A
8
MULLION HEIGHT IN METERS
1.0
10
0
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
Allowable Stress
Design Load
20 PSF (960)
30 PSF (1440)
40 PSF (1920)
50 PSF (2400)
70 PSF (3350)
MULLION CENTERS IN METERS
MULLION HEIGHT IN FEET
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
EC 97911-097
31
AATM 6400/6500/6600 Thermal Window
MAY, 2016
EC 97911-097
LRFD Ultimate
Design Load
33 PSF (1580)
50 PSF (2400)
67 PSF (3200)
83 PSF (4000)
117 PSF (5580)
MULLION CENTERS IN METERS
MULLION CENTERS IN METERS
1.0
1.0
10
3.0
C
7
D2.0
6
E
5
4
1.0
3
2
MULLION HEIGHT IN FEET
8
423523
1
0
1
2
3
4
5
6
MULLION CENTERS IN FEET
3.0
B
9
B
MULLION HEIGHT IN METERS
WIND LOAD CHARTS ARE BASED ON
COMPOSITE PROPERTIES WHICH
ARE CALCULATED IN ACCORDANCE
WITH AAMA TIR-8 AND AAMA 505
UNITS WITH HORIZONTALS
C
D
8
7
E2.0
6
5
4
1.0
3
2
1
0
0
1
2
3
4
5
6
MULLION CENTERS IN FEET
UNITS WITHOUT HORIZONTALS
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
MULLION HEIGHT IN FEET
9
0
10
ADME130EN
kawneer.com
© Kawneer Company, Inc., 2014
A=
B=
C=
D=
E=
Allowable Stress
Design Load
20 PSF (960)
30 PSF (1440)
40 PSF (1920)
50 PSF (2400)
70 PSF (3350)
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
WIND LOAD CHARTS
MULLION HEIGHT IN METERS
32
AATM 6400/6500/6600 Thermal Window
MAY, 2016
DEADLOAD CHARTS
MULLION CENTERS IN METERS
MULLION CENTERS IN METERS
1.0
1.0
6
5
4
1.0
3
2
A
B
C
1
0
1
2
3
4
5
5
4
1.0
3
2
A
B
C
1
0
6
2.0
6
0
1
2
4
5
6
MULLION CENTERS IN FEET
MULLION CENTERS IN FEET
1/16" DEFLECTION
(VENT)
1/8" DEFLECTION
(FIXED)
MULLION CENTERS IN METERS
MULLION CENTERS IN METERS
1.0
1.0
2.0
6
5
4
1.0
3
2
A
B
C
1
0
0
kawneer.com
1
2
3
4
5
A = 1/8 POINT LOADING
B = 1/6 POINT LOADING
C = 1/4 POINT LOADING
423513
6
8
MULLION SPACING IN FEET
7
MULLION SPACING IN METERS
MULLION SPACING IN FEET
3
7
2.0
6
5
4
1.0
3
A
B
C
2
1
0
0
1
2
3
4
5
6
MULLION CENTERS IN FEET
MULLION CENTERS IN FEET
1/16" DEFLECTION
(VENT)
1/8" DEFLECTION
(FIXED)
ADME130EN
MULLION SPACING IN METERS
0
423503
7
MULLION SPACING IN METERS
2.0
A = 1/8 POINT LOADING
B = 1/6 POINT LOADING
C = 1/4 POINT LOADING
8
MULLION SPACING IN FEET
7
MULLION SPACING IN METERS
MULLION SPACING IN FEET
8
8
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
EC 97911-097
33
6
0
2.0
5
4
3
1.0
2
1
A
B
C
0
1
2
3
4
5
A = 1/8 POINT LOADING
B = 1/6 POINT LOADING
C = 1/4 POINT LOADING
423522
6
ADME130EN
MULLION SPACING IN FEET
MULLION CENTERS IN METERS
MULLION CENTERS IN METERS
1.0
8
1.0
7
6
0
2.0
5
4
3
1.0
2
1
A
B
C
0
1
2
3
4
5
6
MULLION CENTERS IN FEET
MULLION CENTERS IN FEET
1/16" DEFLECTION
(VENT)
1/8" DEFLECTION
(FIXED)
kawneer.com
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
DEADLOAD CHARTS
MULLION SPACING IN METERS
AATM 6400/6500/6600 Thermal Window
© Kawneer Company, Inc., 2014
7
MULLION SPACING IN METERS
8
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
MULLION SPACING IN FEET
34
EC 97911-097
MAY, 2016
AATM 6400/6500/6600 Thermal Window
MAY, 2016
EC 97911-097
35
THERMAL CHARTS
Generic Project Specific U-factor Example Calculation
(Percent of Glass will vary on specific products depending on sitelines)
51-3/4"
(1315)
5'-0"
(1524)
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
3'-0"
(915)
27-3/4"
(705)
Example Glass U-Factor = 0.42 Btu/hr • ft2 • °F
Total Daylight Opening
= 27-3/4" • 51-3/4" = 9.97ft2
Total Projected Area
= 3'-0" • 5'-0" = 15 ft2
Percent of Glass
= (Total Daylight Opening ÷ Total Projected Area)100
= (9.97 ÷ 15)100 = 66%
System U-factor vs Percent of Glass Area
0.90
(5.00)
0.80
(4.50)
0.75
0.70
E IGN
PL S
M E
A D
EX FOR
O
© Kawneer Company, Inc., 2014
0.48
0.46
0.44
0.42
0.40
0.38
0.36
0.34
0.32
0.30
0.28
0.26
0.24
0.22
0.20
(2.73)
(2.61)
(2.50)
(2.39)
(2.27)
(2.16)
(2.05)
(1.93)
(1.82)
(1.71)
(1.59)
(1.48)
(1.37)
(1.25)
(1.14)
0.60
0.55
0.53
0.50
0.45
0.35
(2.50)
(2.00)
0.30
0.20
70
66%
65
60
55
Percent of Glass Area
Based on 66% glass and center of glass (COG) U-factor of 0.42
System U-factor is equal to 0.53 Btu/hr • ft2 • °F
kawneer.com
(3.00)
0.40
0.25
75
(3.50)
ADME130EN
50
(1.50)
W
m2 • °C
System U-factor
T
COG
U-factor
(4.00)
0.65
Btu
hr • ft2 • °F
System U-factor
N
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
0.85
AATM 6400/6500/6600 Thermal Window
MAY, 2016
EC 97911-097
THERMAL CHARTS
FIXED WINDOW WITH 1" GLAZING
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
Note:
Values in parentheses are metric.
COG = Center of Glass.
Charts are generated per AMMA 507
System U-factor vs Percent of Glass Area
COG
U-factor
0.47 (2.67)
0.46 (2.61)
0.44 (2.50)
0.42 (2.39)
0.38 (2.16)
0.36 (2.05)
0.34 (1.93)
0.32 (1.82)
0.30 (1.71)
0.28 (1.59)
0.26 (1.48)
0.24 (1.37)
0.22 (1.25)
0.20 (1.14)
0.18 (1.02)
0.16 (0.91)
0.14 (0.79)
0.12 (0.68)
0.10 (0.57)
Percent of Glass Area = Vision Area/Total Area
Daylight Opening / Projected Area
Notes for System U-factor, SHGC and VT charts:
For glass values that are not listed, linear interpolation is permitted.
Glass properties are based on center of glass values and are obtained from your glass supplier.
ADME130EN
kawneer.com
© Kawneer Company, Inc., 2014
0.40 (2.27)
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
Btu
hr • ft2 • °F
System U-factor
36
System VT
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
System SHGC
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
MAY, 2016
kawneer.com
AATM 6400/6500/6600 Thermal Window
EC 97911-097
Vision Area / Total Area (%)
ADME130EN
37
THERMAL CHARTS
FIXED WINDOW WITH 1" GLAZING
System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area
COG
SHGC
Vision Area / Total Area (%)
System Visible Transmittance (VT) vs Percent of Vision Area
COG
VT
AATM 6400/6500/6600 Thermal Window
MAY, 2016
EC 97911-097
THERMAL PERFORMANCE MATRIX (NFRC SIZE)
Thermal Transmittance 1 (BTU/hr • ft 2 • °F)
0.48
0.51
0.46
0.50
0.44
0.48
0.42
0.47
0.40
0.45
0.38
0.43
0.36
0.42
0.34
0.40
0.32
0.38
0.30
0.37
0.28
0.35
0.26
0.34
0.24
0.32
0.22
0.30
0.20
0.29
0.18
0.27
0.16
0.25
0.14
0.23
0.12
0.22
0.10
0.20
FIXED WINDOW WITH 1" GLAZING
NOTE:For glass values that are not listed, linear
interpolation is permitted.
1.
2.
3.
4.
U-Factors are determined in accordance with NFRC 100.
SHGC and VT values are determined in accordance with
NFRC 200.
Glass properties are based on center of glass values and
are obtained from your glass supplier.
Overall U-Factor, SHGC, and VT Matricies are based on
the standard NFRC specimen size of 1200mm wide by
1500mm high (47-1/4" by 59-1/16").
SHGC Matrix 2
Visible Transmittance 2
Glass SHGC 3
Overall SHGC 4
Glass VT 3
Overall VT 4
0.75
0.66
0.75
0.65
0.70
0.61
0.70
0.61
0.65
0.57
0.65
0.57
0.60
0.53
0.60
0.52
0.55
0.48
0.55
0.48
0.50
0.44
0.50
0.44
0.45
0.40
0.45
0.39
0.40
0.35
0.40
0.35
0.35
0.31
0.35
0.30
0.30
0.27
0.30
0.26
0.25
0.22
0.25
0.22
0.20
0.18
0.20
0.17
0.15
0.13
0.15
0.13
0.10
0.09
0.10
0.09
0.05
0.05
0.05
0.04
ADME130EN
kawneer.com
© Kawneer Company, Inc., 2014
Overall U-Factor 4
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
Glass U-Factor 3
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
38
AATM 6400/6500/6600 Thermal Window
MAY, 2016
EC 97911-097
THERMAL CHARTS
FIXED WINDOW WITH 1-3/4" TRIPE GLAZING
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
Note:
Values in parentheses are metric.
COG = Center of Glass.
Charts are generated per AMMA 507
System U-factor vs Percent of Glass Area
COG
U-factor
Btu
hr • ft2 • °F
System U-factor
0.30 (1.71)
0.28 (1.59)
0.26 (1.48)
0.22 (1.25)
0.20 (1.14)
0.18 (1.02)
0.16 (0.91)
0.14 (0.79)
0.12 (0.68)
0.10 (0.57)
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
0.24 (1.37)
Percent of Glass Area = Vision Area/Total Area
Daylight Opening / Projected Area
Notes for System U-factor, SHGC and VT charts:
For glass values that are not listed, linear interpolation is permitted.
Glass properties are based on center of glass values and are obtained from your glass supplier.
kawneer.com
ADME130EN
39
COG
SHGC
COG
VT
Vision Area / Total Area (%)
ADME130EN
kawneer.com
© Kawneer Company, Inc., 2014
THERMAL CHARTS
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
System SHGC
AATM 6400/6500/6600 Thermal Window
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
System VT
40
EC 97911-097
MAY, 2016
FIXED WINDOW WITH 1-3/4" TRIPE GLAZING
System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area
Vision Area / Total Area (%)
System Visible Transmittance (VT) vs Percent of Vision Area
AATM 6400/6500/6600 Thermal Window
MAY, 2016
EC 97911-097
THERMAL PERFORMANCE MATRIX (NFRC SIZE)
FIXED WINDOW WITH 1-3/4" TRIPLE GLAZING
Thermal Transmittance 1 (BTU/hr • ft 2 • °F)
Overall U-Factor 4
0.30
0.35
0.28
0.34
0.26
0.32
0.24
0.30
0.22
0.29
0.20
0.27
0.18
0.25
0.16
0.24
0.14
0.22
0.12
0.20
0.10
0.19
NOTE:For glass values that are not listed, linear
interpolation is permitted.
1.
2.
3.
4.
SHGC Matrix 2
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
Glass U-Factor 3
kawneer.com
41
U-Factors are determined in accordance with NFRC 100.
SHGC and VT values are determined in accordance with
NFRC 200.
Glass properties are based on center of glass values and
are obtained from your glass supplier.
Overall U-Factor, SHGC, and VT Matricies are based on
the standard NFRC specimen size of 1200mm wide by
1500mm high (47-1/4" by 59-1/16").
Visible Transmittance 2
Glass SHGC 3
Overall SHGC 4
Glass VT 3
Overall VT 4
0.75
0.65
0.75
0.65
0.70
0.61
0.70
0.61
0.65
0.57
0.65
0.56
0.60
0.52
0.60
0.52
0.55
0.48
0.55
0.48
0.50
0.44
0.50
0.43
0.45
0.39
0.45
0.39
0.40
0.35
0.40
0.35
0.35
0.31
0.35
0.30
0.30
0.26
0.30
0.26
0.25
0.22
0.25
0.22
0.20
0.18
0.20
0.17
0.15
0.13
0.15
0.13
0.10
0.09
0.10
0.09
0.05
0.05
0.05
0.04
ADME130EN
AATM 6400/6500/6600 Thermal Window
MAY, 2016
EC 97911-097
THERMAL CHARTS
CASEMENT/PROJECT-IN WINDOW WITH 1" GLAZING
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
Note:
Values in parentheses are metric.
COG = Center of Glass.
Charts are generated per AMMA 507
System U-factor vs Percent of Glass Area
COG
U-factor
0.47 (2.67)
0.46 (2.61)
0.44 (2.50)
0.42 (2.39)
0.40 (2.27)
0.36 (2.05)
0.34 (1.93)
0.32 (1.82)
0.30 (1.71)
0.28 (1.59)
0.26 (1.48)
0.24 (1.37)
0.22 (1.25)
0.20 (1.14)
0.18 (1.02)
0.16 (0.91)
0.14 (0.79)
0.12 (0.68)
0.10 (0.57)
Percent of Glass Area = Vision Area/Total Area
Daylight Opening / Projected Area
Notes for System U-factor, SHGC and VT charts:
For glass values that are not listed, linear interpolation is permitted.
Glass properties are based on center of glass values and are obtained from your glass supplier.
ADME130EN
kawneer.com
© Kawneer Company, Inc., 2014
0.38 (2.16)
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
Btu
hr • ft2 • °F
System U-factor
42
System VT
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
System SHGC
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
MAY, 2016
kawneer.com
AATM 6400/6500/6600 Thermal Window
EC 97911-097
Vision Area / Total Area (%)
ADME130EN
43
THERMAL CHARTS
CASEMENT/PROJECT-IN WINDOW WITH 1" GLAZING
System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area
COG
SHGC
Vision Area / Total Area (%)
System Visible Transmittance (VT) vs Percent of Vision Area
COG
VT
AATM 6400/6500/6600 Thermal Window
MAY, 2016
EC 97911-097
THERMAL PERFORMANCE MATRIX (NFRC SIZE)
Thermal Transmittance 1 (BTU/hr • ft 2 • °F)
0.48
0.54
0.46
0.53
0.44
0.52
0.42
0.51
0.40
0.49
0.38
0.48
0.36
0.47
0.34
0.46
0.32
0.45
0.30
0.44
0.28
0.42
0.26
0.41
0.24
0.40
0.22
0.39
0.20
0.38
0.18
0.36
0.16
0.35
0.14
0.34
0.12
0.33
0.10
0.32
CASEMENT/PROJECT-IN WINDOW
WITH 1" GLAZING
NOTE:For glass values that are not listed, linear
interpolation is permitted.
1.
2.
3.
4.
U-Factors are determined in accordance with NFRC 100.
SHGC and VT values are determined in accordance with
NFRC 200.
Glass properties are based on center of glass values and
are obtained from your glass supplier.
Overall U-Factor, SHGC, and VT Matricies are based on
the standard NFRC specimen size of 1500mm wide by
600mm high (59-1/16" by 23-5/8").
SHGC Matrix 2
Visible Transmittance 2
Glass SHGC 3
Overall SHGC 4
Glass VT 3
Overall VT 4
0.75
0.48
0.75
0.47
0.70
0.45
0.70
0.43
0.65
0.42
0.65
0.40
0.60
0.39
0.60
0.37
0.55
0.36
0.55
0.34
0.50
0.33
0.50
0.31
0.45
0.30
0.45
0.28
0.40
0.26
0.40
0.25
0.35
0.23
0.35
0.22
0.30
0.20
0.30
0.19
0.25
0.17
0.25
0.16
0.20
0.14
0.20
0.12
0.15
0.11
0.15
0.09
0.10
0.08
0.10
0.06
0.05
0.05
0.05
0.03
ADME130EN
kawneer.com
© Kawneer Company, Inc., 2014
Overall U-Factor 4
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
Glass U-Factor 3
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
44
AATM 6400/6500/6600 Thermal Window
MAY, 2016
EC 97911-097
THERMAL CHARTS
CASEMENT/PROJECT-IN WINDOW WITH 1-3/4" TRIPE GLAZING
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
Note:
Values in parentheses are metric.
COG = Center of Glass.
Charts are generated per AMMA 507
System U-factor vs Percent of Glass Area
COG
U-factor
Btu
hr • ft2 • °F
System U-factor
0.30 (1.71)
0.28 (1.59)
0.24 (1.37)
0.22 (1.25)
0.20 (1.14)
0.18 (1.02)
0.16 (0.91)
0.14 (0.79)
0.12 (0.68)
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
0.26 (1.48)
0.10 (0.57)
Percent of Glass Area = Vision Area/Total Area
Daylight Opening / Projected Area
Notes for System U-factor, SHGC and VT charts:
For glass values that are not listed, linear interpolation is permitted.
Glass properties are based on center of glass values and are obtained from your glass supplier.
kawneer.com
ADME130EN
45
COG
SHGC
COG
VT
Vision Area / Total Area (%)
ADME130EN
kawneer.com
© Kawneer Company, Inc., 2014
THERMAL CHARTS
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
System SHGC
AATM 6400/6500/6600 Thermal Window
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
System VT
46
EC 97911-097
MAY, 2016
CASEMENT/PROJECT-IN WINDOW WITH 1-3/4" TRIPE GLAZING
System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area
Vision Area / Total Area (%)
System Visible Transmittance (VT) vs Percent of Vision Area
AATM 6400/6500/6600 Thermal Window
MAY, 2016
EC 97911-097
THERMAL PERFORMANCE MATRIX (NFRC SIZE)
CASEMENT/PROJECT-IN WINDOW
WITH 1-3/4" TRIPE GLAZING
Thermal Transmittance 1 (BTU/hr • ft 2 • °F)
Overall U-Factor 4
0.30
0.41
0.28
0.40
0.26
0.39
0.24
0.38
0.22
0.36
0.20
0.35
0.18
0.34
0.16
0.33
0.14
0.32
0.12
0.31
0.10
0.29
NOTE:For glass values that are not listed, linear
interpolation is permitted.
1.
2.
3.
4.
SHGC Matrix 2
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
Glass U-Factor 3
kawneer.com
47
U-Factors are determined in accordance with NFRC 100.
SHGC and VT values are determined in accordance with
NFRC 200.
Glass properties are based on center of glass values and
are obtained from your glass supplier.
Overall U-Factor, SHGC, and VT Matricies are based on
the standard NFRC specimen size of 1500mm wide by
600mm high (59-1/16" by 23-5/8").
Visible Transmittance 2
Glass SHGC 3
Overall SHGC 4
Glass VT 3
Overall VT 4
0.75
0.48
0.75
0.46
0.70
0.45
0.70
0.43
0.65
0.41
0.65
0.40
0.60
0.38
0.60
0.37
0.55
0.35
0.55
0.34
0.50
0.32
0.50
0.31
0.45
0.29
0.45
0.28
0.40
0.26
0.40
0.25
0.35
0.23
0.35
0.21
0.30
0.20
0.30
0.18
0.25
0.17
0.25
0.15
0.20
0.14
0.20
0.12
0.15
0.11
0.15
0.09
0.10
0.08
0.10
0.06
0.05
0.05
0.05
0.03
ADME130EN
AATM 6400/6500/6600 Thermal Window
MAY, 2016
EC 97911-097
THERMAL CHARTS
CASEMENT/PROJECT-OUT WINDOW WITH 1" GLAZING
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
Note:
Values in parentheses are metric.
COG = Center of Glass.
Charts are generated per AMMA 507
System U-factor vs Percent of Glass Area
COG
U-factor
0.47 (2.67)
0.46 (2.61)
0.44 (2.50)
0.42 (2.39)
0.40 (2.27)
0.36 (2.05)
0.34 (1.93)
0.32 (1.82)
0.30 (1.71)
0.28 (1.59)
0.26 (1.48)
0.24 (1.37)
0.22 (1.25)
0.20 (1.14)
0.18 (1.02)
0.16 (0.91)
0.14 (0.79)
0.12 (0.68)
0.10 (0.57)
Percent of Glass Area = Vision Area/Total Area
Daylight Opening / Projected Area
Notes for System U-factor, SHGC and VT charts:
For glass values that are not listed, linear interpolation is permitted.
Glass properties are based on center of glass values and are obtained from your glass supplier.
ADME130EN
kawneer.com
© Kawneer Company, Inc., 2014
0.38 (2.16)
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
Btu
hr • ft2 • °F
System U-factor
48
System VT
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
System SHGC
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
MAY, 2016
kawneer.com
AATM 6400/6500/6600 Thermal Window
EC 97911-097
Vision Area / Total Area (%)
ADME130EN
49
THERMAL CHARTS
CASEMENT/PROJECT-OUT WINDOW WITH 1" GLAZING
System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area
COG
SHGC
Vision Area / Total Area (%)
System Visible Transmittance (VT) vs Percent of Vision Area
COG
VT
AATM 6400/6500/6600 Thermal Window
MAY, 2016
EC 97911-097
THERMAL PERFORMANCE MATRIX (NFRC SIZE)
Thermal Transmittance 1 (BTU/hr • ft 2 • °F)
0.48
0.56
0.46
0.55
0.44
0.54
0.42
0.53
0.40
0.52
0.38
0.51
0.36
0.50
0.34
0.50
0.32
0.49
0.30
0.48
0.28
0.47
0.26
0.46
0.24
0.45
0.22
0.44
0.20
0.43
0.18
0.42
0.16
0.41
0.14
0.40
0.12
0.39
0.10
0.38
CASEMENT/PROJECT-OUT WINDOW
WITH 1" GLAZING
NOTE:For glass values that are not listed, linear
interpolation is permitted.
1.
2.
3.
4.
U-Factors are determined in accordance with NFRC 100.
SHGC and VT values are determined in accordance with
NFRC 200.
Glass properties are based on center of glass values and
are obtained from your glass supplier.
Overall U-Factor, SHGC, and VT Matricies are based on
the standard NFRC specimen size of 600mm wide by
1500mm high (23-5/8" by 59-1/16").
SHGC Matrix 2
Visible Transmittance 2
Glass SHGC 3
Overall SHGC 4
Glass VT 3
Overall VT 4
0.75
0.41
0.75
0.38
0.70
0.38
0.70
0.36
0.65
0.36
0.65
0.33
0.60
0.33
0.60
0.31
0.55
0.31
0.55
0.28
0.50
0.28
0.50
0.26
0.45
0.25
0.45
0.23
0.40
0.23
0.40
0.21
0.35
0.20
0.35
0.18
0.30
0.18
0.30
0.15
0.25
0.15
0.25
0.13
0.20
0.13
0.20
0.10
0.15
0.10
0.15
0.08
0.10
0.07
0.10
0.05
0.05
0.05
0.05
0.03
ADME130EN
kawneer.com
© Kawneer Company, Inc., 2014
Overall U-Factor 4
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
Glass U-Factor 3
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
50
AATM 6400/6500/6600 Thermal Window
MAY, 2016
EC 97911-097
THERMAL CHARTS
CASEMENT/PROJECT-OUT WINDOW WITH 1-3/4" TRIPE GLAZING
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
Note:
Values in parentheses are metric.
COG = Center of Glass.
Charts are generated per AMMA 507
System U-factor vs Percent of Glass Area
Btu
hr • ft2 • °F
System U-factor
COG
U-factor
0.30 (1.71)
0.28 (1.59)
0.24 (1.37)
0.22 (1.25)
0.20 (1.14)
0.18 (1.02)
0.16 (0.91)
0.14 (0.79)
0.12 (0.68)
0.10 (0.57)
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
0.26 (1.48)
Percent of Glass Area = Vision Area/Total Area
Daylight Opening / Projected Area
Notes for System U-factor, SHGC and VT charts:
For glass values that are not listed, linear interpolation is permitted.
Glass properties are based on center of glass values and are obtained from your glass supplier.
kawneer.com
ADME130EN
51
COG
SHGC
System Visible Transmittance (VT) vs Percent of Vision Area
COG
VT
Vision Area / Total Area (%)
ADME130EN
kawneer.com
© Kawneer Company, Inc., 2014
THERMAL CHARTS
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
System SHGC
AATM 6400/6500/6600 Thermal Window
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
System VT
52
EC 97911-097
MAY, 2016
CASEMENT/PROJECT-OUT WINDOW WITH 1-3/4" TRIPE GLAZING
System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area
Vision Area / Total Area (%)
AATM 6400/6500/6600 Thermal Window
MAY, 2016
EC 97911-097
THERMAL PERFORMANCE MATRIX (NFRC SIZE)
CASEMENT/PROJECT-OUT WINDOW
WITH 1-3/4" TRIPE GLAZING
Thermal Transmittance 1 (BTU/hr • ft 2 • °F)
Overall U-Factor 4
0.30
0.45
0.28
0.45
0.26
0.44
0.24
0.43
0.22
0.42
0.20
0.41
0.18
0.40
0.16
0.39
0.14
0.38
0.12
0.37
0.10
0.36
NOTE:For glass values that are not listed, linear
interpolation is permitted.
1.
2.
3.
4.
SHGC Matrix 2
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
Glass U-Factor 3
kawneer.com
53
U-Factors are determined in accordance with NFRC 100.
SHGC and VT values are determined in accordance with
NFRC 200.
Glass properties are based on center of glass values and
are obtained from your glass supplier.
Overall U-Factor, SHGC, and VT Matricies are based on
the standard NFRC specimen size of 600mm wide by
1500mm high (23-5/8" by 59-1/16").
Visible Transmittance 2
Glass SHGC 3
Overall SHGC 4
Glass VT 3
Overall VT 4
0.75
0.40
0.75
0.38
0.70
0.38
0.70
0.36
0.65
0.35
0.65
0.33
0.60
0.33
0.60
0.30
0.55
0.30
0.55
0.28
0.50
0.28
0.50
0.25
0.45
0.25
0.45
0.23
0.40
0.22
0.40
0.20
0.35
0.20
0.35
0.18
0.30
0.17
0.30
0.15
0.25
0.15
0.25
0.13
0.20
0.12
0.20
0.10
0.15
0.10
0.15
0.08
0.10
0.07
0.10
0.05
0.05
0.05
0.05
0.03
ADME130EN
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
AATM 6400/6500/6600 Thermal Window
BLANK PAGE
ADME130EN
kawneer.com
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
54
EC 97911-097
MAY, 2016