AA™6400/6500/6600 6400/6500 Thermal Thermal Window Window The Comfort of Thermal Performance and Condensation Resistance in a Masterful Design A window that keeps what’s on the outside out, while maintaining occupant comfort on the inside is a valuable commodity. The AA™6400/6500/6600 Thermal Window delivers superior thermal and water performance and excellent condensation resistance while meeting the unique challenges of northern climates. A fusion of beauty, strength and functionality, the AA™6400/6500/6600 Thermal Window enhances any application – new and retrofit construction – while delivering architectural aesthetic appeal and ease of installation. Ideal for new and retrofit construction, the AA™6400/6500/6600 Thermal Window enables the designer to leverage aesthetic options while maintaining the thermal integrity of the exterior façade. By employing high-performance polyamide thermal break technology, the window meets or exceeds the highest performance levels set forth by AAMA/WDMA/CSA 101/I.S.2/A440 (NAFS) for windows. With outstanding water performance, condensation resistance and thermal transmittance performance capabilities, the AA™6400/6500/6600 Thermal Window raises the standards for high-performing windows by maintaining occupant comfort on the inside while keeping what’s on the outside out. Performance Fabrication and Installation The high-performing 4" (101.6 mm) deep AA™6400 Thermal Window, 5" (127 mm) deep AA™6500 Thermal Window and 6" (152.4 mm) deep AA™6600 Thermal Window achieve a superb condensation index (I value) and thermal transmittance (U-factor). The advanced design provides the ability to interface with air and vapor barriers to ensure the continuity of the seal at the window perimeter. This window is perfect for punched and strip openings. A specially designed coupling mullion allows the windows to be installed in a multi-modular strip application. The framing systems can accommodate both projected and casement vents. The project out and outswing casement vents can also be installed into curtain wall systems. Additionally, the AA™6400/6500/6600 Thermal Window has a pressure-equalized cavity and a rain screen design that deters water infiltration. The window accommodates 1" (25 mm) or 1-3/4" (44.5 mm) insulating glass units combined with a polyamide thermal break for enhanced thermal performance. The structural aspects of Thermal simulations show temperature the product are also enhanced variations from exterior/cold side through the polyamide thermal to interior/warm side of AA™6400 break connecting the exterior Thermal Window. portion of the frame to the interior portion. This technology permits composite action, thus achieving greater load resistance while still offering design flexibility. Additionally, Casement swing Fixed window the “top hat” accent feature out window with 1" highof the AA™6500/6600 Thermal with 1" highperformance Window provides a deeper performance insulating glass insulating glass 5" and 6" frame for thicker wall construction and greater structural capability. The window is interior glazed, which allows for easy glazing and reglazing in the field – an added benefit in cold climates. Aesthetics and Design Options Kawneer’s AA™6400/6500/6600 Thermal Window offers the versatility in design and the high performance required for today‘s building applications. Whether it is the overall flush appearance provided by the AA™6400 Thermal Window with its extreme frontal placement of glass or the distinctive “top hat” accent feature of the AA™6500/6600 Thermal Window, beauty never has to be sacrificed for functionality. The operable vents have 45° mitered corners, which give the window a smooth and attractive appearance. A dual color option offers the flexibility to vary interior and exterior finishes, enabling designers to coordinate and accent multiple environments. Stylish hardware options include Euro-groove multipoint locking, roto operators, cam handles, pole rings, access control locks and stainless steel 4-bar hinges or concealed hinges. Since the window is made from aluminum, it will never rot, warp or buckle due to moisture and weather exposure. Because it attains outstanding condensation resistance, the window is ideal for healthcare and education applications where condensation and mold are significant concerns. Superior thermal efficiency also makes the window a good choice for buildings seeking Leadership in Energy and Environmental Design certification with the U.S. and Canadian green building councils. Designed to perform above current North American testing standards, the AA™6400/6500/6600 Thermal Window has been fully tested and meets or exceeds the minimum requirements for architectural window performance class, including lifecycle testing. Performance Test Standards Windows are tested in accordance with CSA A440 and AAMA/ WDMA/CSA 101/I.S.2/A440-08 (NAFS). Air Infiltration Water Structural – Uniform Wind Load Thermal Cycling Thermal Transmittance – U-Factor Condensation Resistance (CRF, I, CR) Solar Heat Gain Coefficient (SHGC), Visible Transmittance (VT) Sound Transmission (STC, OITC) ASTM E283 ASTM E331, E547 ASTM E330 AAMA 501.5 AAMA 1503, 507; NFRC 100 AAMA 1503; CSA A440.2; NFRC 500 AAMA 507; NFRC 200 ASTM E90, E1425; AAMA 1801 *Test results available from Kawneer. Contact your Kawneer sales representative for more information. Kawneer Company, Inc. Technology Park / Atlanta 555 Guthridge Court Norcross, GA 30092 kawneer.com kawneergreen.com 770 . 449 . 5555 © Kawneer Company, Inc. 2014 LITHO IN U.S.A. Form No. 13-2174-2 AA™ is a trademark of Kawneer Company, Inc. and Alcoa Inc. The AA™6400 Thermal Window features a flush appearance. The AA™6500 Thermal Window with “top hat” accent feature provides added strength and interest to the sightline. MAY, 2016 AATM 6400/6500/6600 Thermal Window EC 97911-097 INDEX FIXED WINDOW................................................................................ 3-4 AATM6400 FIXED 4" WINDOW...................................................... 5-6 AATM6500 FIXED 5" WINDOW...................................................... 7-8 AATM6600 FIXED 6" WINDOW.................................................... 9-10 PROJECT-IN WINDOW................................................................. 11-14 PROJECT-OUT WINDOW............................................................. 15-18 INSWING CASEMENT WINDOW.................................................. 19-22 OUTSWING CASEMENT WINDOW.............................................. 23-26 MISCELLANEOUS DETAILS............................................................. 27 WIND LOAD CHARTS................................................................... 28-32 DEADLOAD CHARTS................................................................... 33-34 THERMAL CHARTS...................................................................... 35-53 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. LAWS AND BUILDING AND SAFETY CODES GOVERNING THE DESIGN AND USE OF GLAZED ENTRANCE, WINDOW, AND CURTAIN WALL PRODUCTS VARY WIDELY. KAWNEER DOES NOT CONTROL THE SELECTION OF PRODUCT CONFIGURATIONS, OPERATING HARDWARE, OR GLAZING MATERIALS, AND ASSUMES NO RESPONSIBILITY THEREFOR. Metric (SI) conversion figures are included throughout these details for reference. Numbers in parentheses ( ) are millimeters unless otherwise noted. © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 1 The following metric (SI ) units are found in these details: m –meter cm – centimeter mm –millimeter s –second Pa –pascal MPa –megapascal Kawneer reserves the right to change configurations without prior notice when deemed necessary for product improvement. kawneer.com ADME130EN Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. AATM 6400/6500/6600 Thermal Window BLANK PAGE ADME130EN kawneer.com © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 2 EC 97911-097 MAY, 2016 AATM 6400/6500/6600 Thermal Window MAY, 2016 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. EC 97911-097 FIXED WINDOW Features • Architectural Grade Commercial Window • Tested to US and Canadian Standards • Polyamide Thermal Break • Tubular Profiles • Optional "Top Hat" Accent Feature • Rain Screen and Pressure Equalized • Accommodates Air and / or Vapor barrier • Accommodates Projected and Casement Vents • Field Dry Glazed • 1" dual glazing (RSPE with gasket) • 1-3/4" triple glazing (RSPE with silicone heel bead) • Interior Applied Glazing Bead • Architectural Anodized Finishes and Applied Coatings • Interior and Exterior Dual Finish Options • Two Year Manufacturer’s Warranty Exterior © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Thermal Break Fixed Window For specific product applications, Consult your Kawneer representative. kawneer.com ADME130EN Interior 3 FIXED WINDOW CLASS and GRADE Architectural Window Grade AW-PG70-FW TESTING STANDARD AAMA / WDMA / CSA / 101 / I.S.2 / A440 (NAFS) FRAME DEPTH 4" (AATM6400), 5" (AATM6500), or 6" (AATM6600) TYPICAL WALL THICKNESS .070" Nominal Frame INFILL OPTIONS 1" or 1-3/4" STANDARD HARDWARE Not Applicable OPTIONAL HARDWARE Not Applicable OTHER OPTIONS Expansion Mullions ADME130EN Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. AATM 6400/6500/6600 Thermal Window kawneer.com © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 4 EC 97911-097 MAY, 2016 © Kawneer Company, Inc., 2014 3/8" (10) Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. kawneer.com 3/8" (10) 1-3/4" (45) W.D. 4A JAMB D.L.O 3/8" (10) 1-3/4" (45) O.D. D.L.O D.L.O 4 JAMB ADME130EN 2 INTERMEDIATE HORIZONTAL 3 TYPICAL ELEVATION Log onto www.kawneer.com for other configurations 3 SILL 1-5/16" (33) W.D. 2-5/8" (67) W.D. O.D. O.D. 5 TUBULAR MULLION D.L.O 1-5/16" (33) 4A 1-5/16" (33) D.L.O 6 2-5/8" (67) 5 D.L.O 2 D.L.O 1-3/4" (45) 1 HEAD D.L.O 4 O.D. 1 W.D. MAX. 18' 0" 1-3/4" (45) O.D. OVERALL FRAME WIDTH W.D. 3/8" (10) EC 97911-097 W.D. O.D. OVERALL FRAME HEIGHT Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. MAY, 2016 AATM 6400/6500/6600 Thermal Window D.L.O W.D. O.D. 6 JAMB 5 AATM6400 FIXED 4" WINDOW SCALE : 3" = 1'-0" (Nominal Dimensions Shown) 1-5/16" (33) 1-3/4" (45) 3/8" (10) 3/8" (10) 1-3/4" (45) W.D. 4A JAMB D.L.O 2 INTERMEDIATE HORIZONTAL 3 SILL 1-5/16" (33) 3/8" (10) 1-3/4" (45) O.D. 4 JAMB D.L.O D.L.O 2-5/8" (67) 1-5/16" (33) ADME130EN D.L.O D.L.O 4A 3/8" (10) Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 1-5/16" (33) 1-3/4" (45) W.D. D.L.O AATM6400 FIXED 4" WINDOW 1-17/32" (39) 1-17/32" (39) W.D. W.D. 3-1/16" (78) W.D. D.L.O O.D. O.D. O.D. 5 TUBULAR MULLION 6 MULTI-MODULAR COUPLING MULLION kawneer.com © Kawneer Company, Inc., 2014 3 D.L.O 6 1-5/16" (33) 5 W.D. 2 2-5/8" (67) 4 D.L.O 1 1 HEAD D.L.O MAX. 18' 0" W.D. O.D. OVERALL FRAME WIDTH 1-3/4" (45) O.D. AATM 6400/6500/6600 Thermal Window Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 3/8" (10) O.D. OVERALL FRAME HEIGHT 6 EC 97911-097 MAY, 2016 SCALE : 3" = 1'-0" (Nominal Dimensions Shown) TYPICAL ELEVATION Log onto www.kawneer.com for other configurations © Kawneer Company, Inc., 2014 3/8" (10) Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. kawneer.com 1-3/4" (45) 3/8" (10) W.D. 4A JAMB D.L.O 1-3/4" (45) 3/8" (10) O.D. D.L.O D.L.O 4 JAMB ADME130EN 2 INTERMEDIATE HORIZONTAL 3 TYPICAL ELEVATION Log onto www.kawneer.com for other configurations 3 SILL 1-5/16" (33) 2-5/8" (67) W.D. W.D. O.D. O.D. 5 TUBULAR MULLION D.L.O 1-5/16" (33) 4A 1-5/16 (33)" D.L.O 6 2-5/8" (67) 5 D.L.O 2 D.L.O 1-3/4" (45) 1 HEAD D.L.O 4 O.D. 1 W.D. MAX. 18' 0" 1-3/4" (45) O.D. OVERALL FRAME WIDTH W.D. 3/8" (10) EC 97911-097 W.D. O.D. OVERALL FRAME HEIGHT Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. MAY, 2016 AATM 6400/6500/6600 Thermal Window D.L.O W.D. O.D. 6 JAMB 7 AATM6500 FIXED 5" WINDOW SCALE : 3" = 1'-0" (Nominal Dimensions Shown) 1-5/16" (33) 1-3/4" (45) 3/8" (10) 1-3/4" (45) 3/8" (10) W.D. 4A JAMB D.L.O 1-3/4" (45) 3/8" (10) O.D. 4 JAMB D.L.O D.L.O 1-5/16" (33) 2-5/8" (67) 1-5/16" (33) ADME130EN D.L.O TYPICAL ELEVATION Log onto www.kawneer.com for other configurations 3 SILL 3 D.L.O 1-3/4" (45) Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. D.L.O W.D. 3/8" (10) AATM6500 FIXED 5" WINDOW 1-17/32" (39) 3 1/16" (78) 1-17/32" (39) D.L.O W.D. W.D. W.D. O.D. O.D. O.D. 5 TUBULAR MULLION 6 MULTI-MODULAR COUPLING MULLION kawneer.com © Kawneer Company, Inc., 2014 2 INTERMEDIATE HORIZONTAL 1-5/16" (33) D.L.O 6 2-5/8" (67) 5 D.L.O 4A 1-5/16 (33)" 2 1 HEAD D.L.O 4 O.D. 1 1-3/4" (45) O.D. MAX. 18' 0" W.D. OVERALL FRAME WIDTH W.D. O.D. AATM 6400/6500/6600 Thermal Window Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 3/8" (10) OVERALL FRAME HEIGHT 8 EC 97911-097 MAY, 2016 SCALE : 3" = 1'-0" (Nominal Dimensions Shown) © Kawneer Company, Inc., 2014 3/8" (10) Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. kawneer.com 3/8" (10) 1-3/4" (45) W.D. 4A JAMB TYPICAL ELEVATION Log onto www.kawneer.com for other configurations 1-5/16" (33) D.L.O 3/8" (10) 1-3/4" (45) O.D. W.D. D.L.O D.L.O 4 JAMB ADME130EN 2-5/8" (67) W.D. O.D. O.D. 5 TUBULAR MULLION 6 2 INTERMEDIATE HORIZONTAL 3 SILL D.L.O 1-5/16 (33)" 4A 1-5/16" (33) D.L.O 1-3/4" (45) W.D. D.L.O 1 2-5/8" (67) W.D. 5 D.L.O 1 HEAD D.L.O MAX. 18' 0" O.D. OVERALL FRAME WIDTH W.D. 2 O.D. 3/8" (10) EC 97911-097 1-3/4" (45) 4 O.D. OVERALL FRAME HEIGHT Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. MAY, 2016 AATM 6400/6500/6600 Thermal Window D.L.O W.D. O.D. 6 JAMB 9 AATM6600 FIXED 6" WINDOW SCALE : 3" = 1'-0" (Nominal Dimensions Shown) 3 1-5/16" (33) 1-3/4" (45) 3/8" (10) 1-3/4" (45) 3/8" (10) W.D. 4A JAMB TYPICAL ELEVATION Log onto www.kawneer.com for other configurations D.L.O 1-3/4" (45) O.D. 3/8" (10) 4 JAMB D.L.O 2 INTERMEDIATE HORIZONTAL 3 SILL 1-5/16" (33) 1-5/16" (33) D.L.O D.L.O 2-5/8" (67) ADME130EN 6 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 1-5/16" (33) 1-3/4" (45) W.D. D.L.O 3/8" (10) AATM6500 FIXED 6" WINDOW 1-17/32" (39) D.L.O 1-17/32" (39) 3 1/16" (78) D.L.O W.D. W.D. W.D. O.D. O.D. O.D. 5 TUBULAR MULLION 6 MULTI-MODULAR COUPLING MULLION kawneer.com © Kawneer Company, Inc., 2014 3 1-5/16 (33)" D.L.O 5 W.D. 4A 2-5/8" (67) 2 D.L.O 4 1 HEAD D.L.O 1 W.D. O.D. MAX. 18' 0" 1-3/4" (45) O.D. AATM 6400/6500/6600 Thermal Window Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 3/8" (10) O.D. OVERALL FRAME HEIGHT 10 EC 97911-097 MAY, 2016 SCALE : 3" = 1'-0" (Nominal Dimensions Shown) OVERALL FRAME WIDTH AATM 6400/6500/6600 Thermal Window MAY, 2016 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. EC 97911-097 PROJECT-IN WINDOW Features • Architectural Grade Commercial Window • Tested to US and Canadian Standards • Polyamide Thermal Break • Accentuated Tubular Profiles • Field Dry Glazed • 1" dual glazing (RSPE with gasket) • 1-3/4" triple glazing (RSPE with silicone heel bead) • Adjustable EURO-Groove Mounted Hardware • Single Handle Multi-Point Locking • Interior Applied Glazing Bead • Architectural Anodized Finishes and Applied Coatings • Interior and Exterior Dual Finish Options • Two Year Manufacturer’s Warranty Exterior © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Thermal Break Project-in Window For specific product applications, Consult your Kawneer representative. kawneer.com ADME130EN Interior 11 AATM 6400/6500/6600 Thermal Window MAY, 2016 EC 97911-097 Architectural Window Grade AW-PG70-AP TESTING STANDARD AAMA / WDMA / CSA / 101 / I.S.2 / A440 (NAFS) FIXED FRAMING DEPTH 4" (AATM6400), 5" (AATM6500), or 6" (AATM6600) VENT DEPTH 3-9/16" TYPICAL WALL THICKNESS .070" Nominal Frame / .070" Nominal Vent TYPICAL MAX. SIZE (Sizes are for fixed frame D.L.O.) 60" x 36" TYPICAL MIN. SIZE (Sizes are for fixed frame D.L.O.) 18" x 22" INFILL OPTIONS 1" or 1-3/4" STANDARD HARDWARE Stainless Steel 4-Bar Hinges Single Handle Multi-Point Locking OPTIONAL HARDWARE Single Keyed Handle Multi-Point Locking Limit Stop OTHER OPTIONS Insect Screens ADME130EN kawneer.com © Kawneer Company, Inc., 2014 CLASS and GRADE Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. PROJECT-IN WINDOW Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 12 © Kawneer Company, Inc., 2014 3/8" (10) Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 3/8" (10) kawneer.com TYPICAL ELEVATION Log onto www.kawneer.com for other configurations 1-3/4" (45) 1-3/4" (45) D.L.O O.D. W.D. 3 VENT JAMB ADME130EN D.L.O 3 AATM6400 details shown, AATM6500 and AATM6600 shown dotted in. D.L.O 1-3/4" (45) W.D. 4 D.L.O 2 VENT SILL W.D. O.D. 4 VENT JAMB 2-5/8" (67) W.D. 1-5/16" (33) 1 VENT HEAD 1-5/16" (33) 2-5/8" (67) 1-5/16" (33) 1-3/4" (45) EC 97911-097 1-3/4" (45) 1-3/4" (45) O.D. 1 O.D. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. MAY, 2016 AATM 6400/6500/6600 Thermal Window PROJECT-IN WINDOW SCALE : 3" = 1'-0" (Nominal Dimensions Shown) 2 3-9/16" (90.5) 4" (AA6400) 5" (AA6500) 6" (AA6600) 1-5/16" (33) D.L.O 13 AATM 6400/6500/6600 Thermal Window MAY, 2016 EC 97911-097 A standard hinge for ventilators providing approximately 45° to 60° openings depending on size. An optional limit stop is available to restrict hinge travel and limit vent opening. MULTI-POINT LOCKING Single handle multi-point locking is standard providing any number of concealed EURO-Groove mounted locking points around the ventilator perimeter. Stylish handles are available in a silver painted finish. MULTI-POINT LOCKING - KEYED Single keyed handle multi-point locking providing any number of concealed EURO-Groove mounted locking points around the ventilator perimeter. Stylish handles are available in a silver painted finish. Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. STAINLESS STEEL 4 BAR HINGES ADME130EN kawneer.com © Kawneer Company, Inc., 2014 PROJECT-IN WINDOW Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 14 AATM 6400/6500/6600 Thermal Window MAY, 2016 PROJECT-OUT WINDOW Features • Architectural Grade Commercial Window • Tested to US and Canadian Standards • Polyamide Thermal Break • Accentuated Tubular Profiles • Field Dry Glazed • 1" dual glazing (RSPE with gasket) • 1-3/4" triple glazing (RSPE with silicone heel bead) • Adjustable EURO-Groove Mounted Hardware • Dual Handle Multi-Point Locking • Interior Applied Glazing Bead • Architectural Anodized Finishes and Applied Coatings • Interior and Exterior Dual Finish Options • Two Year Manufacturer’s Warranty • Compatible with Curtain Wall Systems Thermal Break Exterior © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. EC 97911-097 Project-out Window For specific product applications, Consult your Kawneer representative. kawneer.com ADME130EN Interior 15 AATM 6400/6500/6600 Thermal Window MAY, 2016 EC 97911-097 Architectural Window Grade AW-PG70-AP TESTING STANDARD AAMA / WDMA / CSA / 101 / I.S.2 / A440 (NAFS) FIXED FRAMING DEPTH 4" (AATM6400), 5" (AATM6500), or 6" (AATM6600) VENT / VENT FRAME DEPTH 3-3/8" TYPICAL WALL THICKNESS .070" Nominal Frame / .070" Nominal Vent TYPICAL MAX. SIZE (Sizes are for fixed frame D.L.O.) 60" x 36" TYPICAL MIN. SIZE (Sizes are for fixed frame D.L.O.) 28" x 20" INFILL OPTIONS 1" or 1-3/4" STANDARD HARDWARE Stainless Steel 4-Bar Hinges Dual Handle Multi-Point Locking Pivot Shoe Roto OPTIONAL HARDWARE Dual Handle Multi-Point Locking - Keyed Cam Handles Access Control Locks Pole and Hanger OTHER OPTIONS Insect Screens ADME130EN kawneer.com © Kawneer Company, Inc., 2014 CLASS and GRADE Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. PROJECT-OUT WINDOW Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 16 © Kawneer Company, Inc., 2014 3/8" (10) Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. TYPICAL ELEVATION Log onto www.kawneer.com for other configurations TM AA 6400 details shown, AA 6500 and AA 6600 shown dotted in. kawneer.com TM 1-3/4" (45) 3/8" (10) 2-7/8" (73) TM W.D. D.L.O O.D. 3 VENT JAMB ADME130EN 2 VENT SILL D.L.O 1-3/4" (45) W.D. 2 D.L.O 4 D.L.O 1 W.D. 2-5/8" (67) 1 VENT HEAD 2-7/8" (73) W.D. O.D. 4 VENT JAMB 1-5/16" (93) 2-7/8" (73) O.D. D.L.O 1-5/16" (33) EC 97911-097 2-7/8" (73) 3 O.D. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. MAY, 2016 AATM 6400/6500/6600 Thermal Window PROJECT-OUT WINDOW SCALE : 3" = 1'-0" (Nominal Dimensions Shown) 3-3/8" (85.7) 4" (AA6400) 5" (AA6500) 6" (AA6600) 1-5/16" (33) 2-5/8" (67) 1-5/16" (33) D.L.O 17 AATM 6400/6500/6600 Thermal Window MAY, 2016 EC 97911-097 A standard hinge for ventilators providing a 4" opening to comply with child safety requirements. MULTI-POINT LOCKING Single handle multi-point locking is standard providing any number of concealed EURO-Groove mounted locking points around the ventilator perimeter. Stylish handles are available in a silver painted finish. MULTI-POINT LOCKING - KEYED Single keyed handle multi-point locking providing any number of concealed EURO-Groove mounted locking points around the ventilator perimeter. Stylish handles are available in a silver painted finish. PIVOT-SHOE ROTO-OPERATOR Pivot shoe roto operator is located on the center line of the bottom horizontal frame. Standard finish shall be painted silver. STANDARD CAM HANDLE Cast white bronze cam handles are standard for the manual operation and locking of ventilators. CAM HANDLE WITH POLE RING Cast white bronze cam handles with pole ring provide manual operation of ventilators located above reach. These handles are operated with a sash pole. POLE RING Cast white bronze pole ring is used in conjunction with locking hardware for sash pole operation of ventilators. SASH POLE A 3/4" diameter aluminum sash pole with a cast white bronze pull down hook and black rubber tip. Available in 6 ft. and 12 ft. lengths with optional cast white bronze Pole Hanger. HANGER FOR SASH POLE ACCESS CONTROL LOCK In lieu of cam handles cast white bronze access control locks are offered for managed control of vent operations. Lock is operated with a manganese bronze removable handle. ADME130EN kawneer.com © Kawneer Company, Inc., 2014 STAINLESS STEEL 4 BAR HINGES Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. PROJECT-OUT WINDOW Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 18 MAY, 2016 AATM 6400/6500/6600 Thermal Window INSWING CASEMENT WINDOW Features • Architectural Grade Commercial Window • Tested to US and Canadian Standards • Polyamide Thermal Break • Accentuated Tubular Profiles • Field Dry Glazed • 1" dual glazing (RSPE with gasket) • 1-3/4" triple glazing (RSPE with silicone heel bead) • Adjustable EURO-Groove Mounted Hardware • Single Handle Multi-Point Locking • Interior Applied Glazing Bead • Architectural Anodized Finishes and Applied Coatings • Interior and Exterior Dual Finish Options • Two Year Manufacturer’s Warranty Thermal Break Interior © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. EC 97911-097 Exterior HINGED LEFT Inswing Casement Window For specific product applications, Consult your Kawneer representative. kawneer.com ADME130EN 19 AATM 6400/6500/6600 Thermal Window MAY, 2016 EC 97911-097 Architectural Window Grade AW-PG70-C TESTING STANDARD AAMA / WDMA / CSA / 101 / I.S.2 / A440 (NAFS) FRAME DEPTH 4" (AATM6400), 5" (AATM6500), or 6" (AATM6600) VENT DEPTH 3-9/16" TYPICAL WALL THICKNESS .070" Nominal Frame / .070" Nominal Vent TYPICAL MAX. SIZE (Sizes are for fixed frame D.L.O.) 36" x 60" TYPICAL MIN. SIZE (Sizes are for fixed frame D.L.O.) 22" x 22" INFILL OPTIONS 1" or 1-3/4" STANDARD HARDWARE Stainless Steel 4-Bar Hinges Single Handle Multi-Point Locking OPTIONAL HARDWARE Single Keyed Handle Multi-Point Locking Limit Stop OTHER OPTIONS Insect Screens ADME130EN kawneer.com © Kawneer Company, Inc., 2014 CLASS and GRADE Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. INSWING CASEMENT WINDOW Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 20 © Kawneer Company, Inc., 2014 kawneer.com 2 3/8" (10) 2 VENT SILL 1-3/4" (45) 1-3/4" (45) W.D. D.L.O D.L.O O.D. 3 VENT JAMB ADME130EN D.L.O HINGED LEFT W.D. 3 AATM6400 details shown, AATM6500 and AATM6600 shown dotted in. 3/8" (10) O.D. 4 D.L.O 3/8" (10) 1 1 VENT HEAD TYPICAL ELEVATION Log onto www.kawneer.com for other configurations 1-3/4" (45) 1-3/4" (45) 1-3/4" (45) W.D. O.D. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. EC 97911-097 1-3/4" (45) 1-3/4" (45) Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. MAY, 2016 AATM 6400/6500/6600 Thermal Window INSWING CASEMENT WINDOW SCALE : 3" = 1'-0" (Nominal Dimensions Shown) 3-9/16" (90.5) 4" (AA6400) 5" (AA6500) 6" (AA6600) 1-5/16" (33) 1-5/16" (33) W.D. 2-5/8" (67) O.D. 4 VENT JAMB D.L.O 21 AATM 6400/6500/6600 Thermal Window MAY, 2016 EC 97911-097 A standard hinge for ventilators providing up to 45° of open. An optional limit stop is available to restrict hinge travel and limit vent opening. MULTI-POINT LOCKING Single handle multi-point locking is standard providing any number of concealed EURO-Groove mounted locking points around the ventilator perimeter. Stylish handles are available in a silver painted finish. MULTI-POINT LOCKING - KEYED Single keyed handle multi-point locking providing any number of concealed EURO-Groove mounted locking points around the ventilator perimeter. Stylish handles are available in a silver painted finish. Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. STAINLESS STEEL 4 BAR HINGES ADME130EN kawneer.com © Kawneer Company, Inc., 2014 INSWING CASEMENT WINDOW Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 22 MAY, 2016 AATM 6400/6500/6600 Thermal Window OUTSWING CASEMENT WINDOW Features • Architectural Grade Commercial Window • Tested to US and Canadian Standards • Polyamide Thermal Break • Accentuated Tubular Profiles • Field Dry Glazed • 1" dual glazing (RSPE with gasket) • 1-3/4" triple glazing (RSPE with silicone heel bead) • Adjustable EURO-Groove Mounted Hardware • Single Handle Multi-Point Locking • Interior Applied Glazing Bead • Architectural Anodized Finishes and Applied Coatings • Interior and Exterior Dual Finish Options • Two Year Manufacturer’s Warranty • Compatible with Curtain Wall Systems Interior Exterior HINGED LEFT © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. EC 97911-097 Outswing Casement Window Thermal Break For specific product applications, Consult your Kawneer representative. kawneer.com ADME130EN 23 AATM 6400/6500/6600 Thermal Window MAY, 2016 EC 97911-097 Architectural Window Grade AW-PG70-C TESTING STANDARD AAMA / WDMA / CSA / 101 / I.S.2 / A440 (NAFS) FIXED FRAMING DEPTH 4" (AATM6400), 5" (AATM6500), or 6" (AATM6600) VENT / VENT FRAME DEPTH 3-3/8" TYPICAL WALL THICKNESS .070" Nominal Frame / .070" Nominal Vent TYPICAL MAX. SIZE (Sizes are for fixed frame D.L.O.) 36" x 60" TYPICAL MIN. SIZE (Sizes are for fixed frame D.L.O.) 18" x 18" INFILL OPTIONS 1" or 1-3/4" STANDARD HARDWARE Concealed Hinge Single Handle Multi-Point Locking Roto Operator OPTIONAL HARDWARE Single Keyed Handle Multi-Point Locking Cam Handles 4-bar Hinges Pole and Hanger OTHER OPTIONS Insect Screens ADME130EN kawneer.com © Kawneer Company, Inc., 2014 CLASS and GRADE Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. OUTSWING CASEMENT WINDOW Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 24 © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. kawneer.com TYPICAL ELEVATION Log onto www.kawneer.com for other configurations AATM6400 details shown, AATM6500 and AATM6600 shown dotted in. 1-3/4" (45) 3/8" (10) 2-7/8" (73) D.L.O W.D. O.D. 3 VENT JAMB ADME130EN 1-3/4" (45) 2 VENT SILL 2 D.L.O D.L.O D.L.O W.D. 1-3/4" (45) 1 VENT HEAD 2-7/8" (73) W.D. O.D. 4 VENT JAMB 2-7/8" (73) 1 W.D. O.D. 3/8" (10) EC 97911-097 2-7/8" (73) HINGED LEFT 3/8" (10) 3 O.D. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. MAY, 2016 AATM 6400/6500/6600 Thermal Window OUTSWING CASEMENT WINDOW SCALE : 3" = 1'-0" (Nominal Dimensions Shown) 4 3-3/8" (85.7) 4" (AA6400) 5" (AA6500) 6" (AA6600) 1-5/16" (33) 2-5/8" (67) 1-5/16" (33) D.L.O 25 AATM 6400/6500/6600 Thermal Window MAY, 2016 EC 97911-097 A standard hinge for outswing ventilators. MULTI-POINT LOCKING Single handle multi-point locking is standard providing any number of concealed EURO-Groove mounted locking points around the ventilator perimeter. Stylish handles are available in a silver painted finish. MULTI-POINT LOCKING - KEYED Single keyed handle multi-point locking providing any number of concealed EURO-Groove mounted locking points around the ventilator perimeter. Stylish handles are available in a silver painted finish. ROTO-OPERATOR Roto operator is located on the bottom horizontal vent-frame. Standard finish shall be painted silver. STANDARD CAM HANDLE Cast white bronze cam handles are standard for the manual operation and locking of ventilators. CAM HANDLE WITH POLE RING Cast white bronze cam handles with pole ring provide manual operation of ventilators located above reach. These handles are operated with a sash pole. SASH POLE A 3/4" diameter aluminum sash pole with a cast white bronze pull down hook and black rubber tip. Available in 6 ft. and 12 ft. lengths with optional cast white bronze Pole Hanger. HANGER FOR SASH POLE ACCESS CONTROL LOCK In lieu of cam handles cast white bronze access control locks are offered for managed control of vent operations. Lock is operated with a manganese bronze removable handle. KEYED LIMIT ARM Key released limit arms may be used to restrict ventilator opening when used with cam handles or access control locks. ADME130EN kawneer.com © Kawneer Company, Inc., 2014 CONCEALED HINGES Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. OUTSWING CASEMENT WINDOW Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 26 © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. MAY, 2016 kawneer.com AATM 6400/6500/6600 Thermal Window EC 97911-097 MISCELLANEOUS SCALE : 3" = 1'-0" (Nominal Dimensions Shown) TRIM DETAILS TRIPLE GLAZED HEAD HEAD ANCHORS SILL CURTAIN WALL ADAPTERS TYPICAL SILL EXTENSION FLANGE LEG FRAME 1600UT SYSTEMTM 1 CURTAIN WALL (Project-Out/Outswing Casement) HEAD RECEPTOR 1600UT SYSTEMTM 1 CURTAIN WALL (Project-In/Inswing Casement) ADME130EN 27 28 AATM 6400/6500/6600 Thermal Window WIND LOAD / DEADLOAD CHARTS MAY, 2016 EC 97911-097 DEADLOAD CHARTS Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Horizontal or deadload limitations are based upon 1/16" (1.6) at operable vents or 1/8" (3.2) at fixed openings, maximum allowable deflection at the center of an intermediate horizontal member. The accompanying charts are calculated for 1" (25.4) thick insulating glass supported on two setting blocks placed at the loading points shown. ADME130EN kawneer.com © Kawneer Company, Inc., 2014 Mullions are designed for deflection limitations in accordance with AAMA TIR-A11 of L/175 up to 13'-6" and L/240 +1/4" above 13'-6". These curves are for mullions WITH HORIZONTALS and are based on engineering calculations for stress and deflection. Allowable wind load stress for ALUMINUM 15,152 psi (104MPa), STEEL 30,000 psi (207MPa). Charted curves, in all cases are for the limiting value. Wind load charts contained herein are based upon nominal wind load utilized in allowable stress design. A conversion from Load Resistance Factor Design (LRFD) is provided. To convert ultimate wind loads to nominal loads, multiply ultimate wind loads by a factor of 0.6 per ASCE/SEI 7. A 4/3 increase in allowable stress has not been used to develop these curves. For special situations not covered by these curves, contact your Kawneer representative for additional information. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. WIND LOAD CHARTS AATM 6400/6500/6600 Thermal Window MAY, 2016 WIND LOAD CHARTS A= B= C= D= E= LRFD Ultimate Design Load 33 PSF (1580) 50 PSF (2400) 67 PSF (3200) 83 PSF (4000) 117 PSF (5580) MULLION CENTERS IN METERS 1.0 1.0 10 3.0 9 8 8 2.0 6 A 5 B C D1.0 E 4 3 2 MULLION HEIGHT IN FEET 7 MULLION HEIGHT IN METERS 9 423505 1 1 2 3 4 5 MULLION CENTERS IN FEET 2.0 B C D E 6 5 4 1.0 3 2 1 WIND LOAD CHARTS ARE BASED ON COMPOSITE PROPERTIES WHICH ARE CALCULATED IN ACCORDANCE WITH AAMA TIR-8 AND AAMA 505 6 A 7 0 0 1 2 5 6 MULLION CENTERS IN FEET UNITS WITHOUT HORIZONTALS MULLION CENTERS IN METERS MULLION CENTERS IN METERS 1.0 1.0 10 3.0 7 2.0 A 6 5 B 4 C D1.0 E 3 2 1 MULLION HEIGHT IN FEET 8 0 3.0 9 MULLION HEIGHT IN METERS 9 MULLION HEIGHT IN FEET 4 UNITS WITH HORIZONTALS 10 © Kawneer Company, Inc., 2014 3 1 2 3 4 5 6 MULLION CENTERS IN FEET UNITS WITH HORIZONTALS kawneer.com 7 B 2.0 6 C D E 5 4 1.0 3 2 423513 0 A 8 WIND LOAD CHARTS ARE BASED ON COMPOSITE PROPERTIES WHICH ARE CALCULATED IN ACCORDANCE WITH AAMA TIR-8 AND AAMA 505 ADME130EN 1 0 0 1 2 3 4 5 6 MULLION CENTERS IN FEET UNITS WITHOUT HORIZONTALS MULLION HEIGHT IN METERS 0 3.0 MULLION HEIGHT IN METERS 10 0 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Allowable Stress Design Load 20 PSF (960) 30 PSF (1440) 40 PSF (1920) 50 PSF (2400) 70 PSF (3350) MULLION CENTERS IN METERS MULLION HEIGHT IN FEET Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. EC 97911-097 29 AATM 6400/6500/6600 Thermal Window MAY, 2016 WIND LOAD CHARTS EC 97911-097 LRFD Ultimate Design Load 33 PSF (1580) 50 PSF (2400) 67 PSF (3200) 83 PSF (4000) 117 PSF (5580) MULLION CENTERS IN METERS MULLION CENTERS IN METERS 1.0 1.0 10 10 3.0 A 7 2.0 6 B 5 C D E1.0 4 3 2 423522 1 0 1 2 3 4 5 6 MULLION CENTERS IN FEET WIND LOAD CHARTS ARE BASED ON COMPOSITE PROPERTIES WHICH ARE CALCULATED IN ACCORDANCE WITH AAMA TIR-8 AND AAMA 505 UNITS WITH HORIZONTALS 8 B 7 6 2.0 C D 5 E 4 1.0 3 2 1 0 0 1 2 3 4 5 6 MULLION CENTERS IN FEET UNITS WITHOUT HORIZONTALS Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 0 MULLION HEIGHT IN FEET 8 MULLION HEIGHT IN METERS 9 MULLION HEIGHT IN METERS MULLION HEIGHT IN FEET 9 3.0 A ADME130EN kawneer.com © Kawneer Company, Inc., 2014 A= B= C= D= E= Allowable Stress Design Load 20 PSF (960) 30 PSF (1440) 40 PSF (1920) 50 PSF (2400) 70 PSF (3350) Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 30 AATM 6400/6500/6600 Thermal Window MAY, 2016 WIND LOAD CHARTS A= B= C= D= E= LRFD Ultimate Design Load 33 PSF (1580) 50 PSF (2400) 67 PSF (3200) 83 PSF (4000) 117 PSF (5580) MULLION CENTERS IN METERS 1.0 10 3.0 3.0 9 A 7 B2.0 6 C 5 D 4 E 1.0 3 2 MULLION HEIGHT IN FEET 8 MULLION HEIGHT IN METERS 9 1 2 3 4 5 MULLION CENTERS IN FEET 5 4 1.0 3 1 WIND LOAD CHARTS ARE BASED ON COMPOSITE PROPERTIES WHICH ARE CALCULATED IN ACCORDANCE WITH AAMA TIR-8 AND AAMA 505 6 6 0 0 1 2 5 6 MULLION CENTERS IN FEET UNITS WITHOUT HORIZONTALS MULLION CENTERS IN METERS MULLION CENTERS IN METERS 1.0 1.0 10 3.0 9 B 7 2.0 C D 6 5 E 4 1.0 3 2 MULLION HEIGHT IN FEET 8 1 0 3.0 A 9 A MULLION HEIGHT IN METERS MULLION HEIGHT IN FEET 4 UNITS WITH HORIZONTALS 10 © Kawneer Company, Inc., 2014 3 B C D2.0 E 8 7 6 5 4 1.0 3 2 1 423514 0 1 2 3 4 5 6 MULLION CENTERS IN FEET UNITS WITH HORIZONTALS kawneer.com WIND LOAD CHARTS ARE BASED ON COMPOSITE PROPERTIES WHICH ARE CALCULATED IN ACCORDANCE WITH AAMA TIR-8 AND AAMA 505 ADME130EN 0 0 1 2 3 4 5 6 MULLION CENTERS IN FEET UNITS WITHOUT HORIZONTALS MULLION HEIGHT IN METERS 0 B C2.0 D E 7 2 423504 1 A 8 MULLION HEIGHT IN METERS 1.0 10 0 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Allowable Stress Design Load 20 PSF (960) 30 PSF (1440) 40 PSF (1920) 50 PSF (2400) 70 PSF (3350) MULLION CENTERS IN METERS MULLION HEIGHT IN FEET Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. EC 97911-097 31 AATM 6400/6500/6600 Thermal Window MAY, 2016 EC 97911-097 LRFD Ultimate Design Load 33 PSF (1580) 50 PSF (2400) 67 PSF (3200) 83 PSF (4000) 117 PSF (5580) MULLION CENTERS IN METERS MULLION CENTERS IN METERS 1.0 1.0 10 3.0 C 7 D2.0 6 E 5 4 1.0 3 2 MULLION HEIGHT IN FEET 8 423523 1 0 1 2 3 4 5 6 MULLION CENTERS IN FEET 3.0 B 9 B MULLION HEIGHT IN METERS WIND LOAD CHARTS ARE BASED ON COMPOSITE PROPERTIES WHICH ARE CALCULATED IN ACCORDANCE WITH AAMA TIR-8 AND AAMA 505 UNITS WITH HORIZONTALS C D 8 7 E2.0 6 5 4 1.0 3 2 1 0 0 1 2 3 4 5 6 MULLION CENTERS IN FEET UNITS WITHOUT HORIZONTALS Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. MULLION HEIGHT IN FEET 9 0 10 ADME130EN kawneer.com © Kawneer Company, Inc., 2014 A= B= C= D= E= Allowable Stress Design Load 20 PSF (960) 30 PSF (1440) 40 PSF (1920) 50 PSF (2400) 70 PSF (3350) Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. WIND LOAD CHARTS MULLION HEIGHT IN METERS 32 AATM 6400/6500/6600 Thermal Window MAY, 2016 DEADLOAD CHARTS MULLION CENTERS IN METERS MULLION CENTERS IN METERS 1.0 1.0 6 5 4 1.0 3 2 A B C 1 0 1 2 3 4 5 5 4 1.0 3 2 A B C 1 0 6 2.0 6 0 1 2 4 5 6 MULLION CENTERS IN FEET MULLION CENTERS IN FEET 1/16" DEFLECTION (VENT) 1/8" DEFLECTION (FIXED) MULLION CENTERS IN METERS MULLION CENTERS IN METERS 1.0 1.0 2.0 6 5 4 1.0 3 2 A B C 1 0 0 kawneer.com 1 2 3 4 5 A = 1/8 POINT LOADING B = 1/6 POINT LOADING C = 1/4 POINT LOADING 423513 6 8 MULLION SPACING IN FEET 7 MULLION SPACING IN METERS MULLION SPACING IN FEET 3 7 2.0 6 5 4 1.0 3 A B C 2 1 0 0 1 2 3 4 5 6 MULLION CENTERS IN FEET MULLION CENTERS IN FEET 1/16" DEFLECTION (VENT) 1/8" DEFLECTION (FIXED) ADME130EN MULLION SPACING IN METERS 0 423503 7 MULLION SPACING IN METERS 2.0 A = 1/8 POINT LOADING B = 1/6 POINT LOADING C = 1/4 POINT LOADING 8 MULLION SPACING IN FEET 7 MULLION SPACING IN METERS MULLION SPACING IN FEET 8 8 © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. EC 97911-097 33 6 0 2.0 5 4 3 1.0 2 1 A B C 0 1 2 3 4 5 A = 1/8 POINT LOADING B = 1/6 POINT LOADING C = 1/4 POINT LOADING 423522 6 ADME130EN MULLION SPACING IN FEET MULLION CENTERS IN METERS MULLION CENTERS IN METERS 1.0 8 1.0 7 6 0 2.0 5 4 3 1.0 2 1 A B C 0 1 2 3 4 5 6 MULLION CENTERS IN FEET MULLION CENTERS IN FEET 1/16" DEFLECTION (VENT) 1/8" DEFLECTION (FIXED) kawneer.com Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. DEADLOAD CHARTS MULLION SPACING IN METERS AATM 6400/6500/6600 Thermal Window © Kawneer Company, Inc., 2014 7 MULLION SPACING IN METERS 8 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. MULLION SPACING IN FEET 34 EC 97911-097 MAY, 2016 AATM 6400/6500/6600 Thermal Window MAY, 2016 EC 97911-097 35 THERMAL CHARTS Generic Project Specific U-factor Example Calculation (Percent of Glass will vary on specific products depending on sitelines) 51-3/4" (1315) 5'-0" (1524) Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 3'-0" (915) 27-3/4" (705) Example Glass U-Factor = 0.42 Btu/hr • ft2 • °F Total Daylight Opening = 27-3/4" • 51-3/4" = 9.97ft2 Total Projected Area = 3'-0" • 5'-0" = 15 ft2 Percent of Glass = (Total Daylight Opening ÷ Total Projected Area)100 = (9.97 ÷ 15)100 = 66% System U-factor vs Percent of Glass Area 0.90 (5.00) 0.80 (4.50) 0.75 0.70 E IGN PL S M E A D EX FOR O © Kawneer Company, Inc., 2014 0.48 0.46 0.44 0.42 0.40 0.38 0.36 0.34 0.32 0.30 0.28 0.26 0.24 0.22 0.20 (2.73) (2.61) (2.50) (2.39) (2.27) (2.16) (2.05) (1.93) (1.82) (1.71) (1.59) (1.48) (1.37) (1.25) (1.14) 0.60 0.55 0.53 0.50 0.45 0.35 (2.50) (2.00) 0.30 0.20 70 66% 65 60 55 Percent of Glass Area Based on 66% glass and center of glass (COG) U-factor of 0.42 System U-factor is equal to 0.53 Btu/hr • ft2 • °F kawneer.com (3.00) 0.40 0.25 75 (3.50) ADME130EN 50 (1.50) W m2 • °C System U-factor T COG U-factor (4.00) 0.65 Btu hr • ft2 • °F System U-factor N Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 0.85 AATM 6400/6500/6600 Thermal Window MAY, 2016 EC 97911-097 THERMAL CHARTS FIXED WINDOW WITH 1" GLAZING Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. Note: Values in parentheses are metric. COG = Center of Glass. Charts are generated per AMMA 507 System U-factor vs Percent of Glass Area COG U-factor 0.47 (2.67) 0.46 (2.61) 0.44 (2.50) 0.42 (2.39) 0.38 (2.16) 0.36 (2.05) 0.34 (1.93) 0.32 (1.82) 0.30 (1.71) 0.28 (1.59) 0.26 (1.48) 0.24 (1.37) 0.22 (1.25) 0.20 (1.14) 0.18 (1.02) 0.16 (0.91) 0.14 (0.79) 0.12 (0.68) 0.10 (0.57) Percent of Glass Area = Vision Area/Total Area Daylight Opening / Projected Area Notes for System U-factor, SHGC and VT charts: For glass values that are not listed, linear interpolation is permitted. Glass properties are based on center of glass values and are obtained from your glass supplier. ADME130EN kawneer.com © Kawneer Company, Inc., 2014 0.40 (2.27) Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Btu hr • ft2 • °F System U-factor 36 System VT © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. System SHGC Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. MAY, 2016 kawneer.com AATM 6400/6500/6600 Thermal Window EC 97911-097 Vision Area / Total Area (%) ADME130EN 37 THERMAL CHARTS FIXED WINDOW WITH 1" GLAZING System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area COG SHGC Vision Area / Total Area (%) System Visible Transmittance (VT) vs Percent of Vision Area COG VT AATM 6400/6500/6600 Thermal Window MAY, 2016 EC 97911-097 THERMAL PERFORMANCE MATRIX (NFRC SIZE) Thermal Transmittance 1 (BTU/hr • ft 2 • °F) 0.48 0.51 0.46 0.50 0.44 0.48 0.42 0.47 0.40 0.45 0.38 0.43 0.36 0.42 0.34 0.40 0.32 0.38 0.30 0.37 0.28 0.35 0.26 0.34 0.24 0.32 0.22 0.30 0.20 0.29 0.18 0.27 0.16 0.25 0.14 0.23 0.12 0.22 0.10 0.20 FIXED WINDOW WITH 1" GLAZING NOTE:For glass values that are not listed, linear interpolation is permitted. 1. 2. 3. 4. U-Factors are determined in accordance with NFRC 100. SHGC and VT values are determined in accordance with NFRC 200. Glass properties are based on center of glass values and are obtained from your glass supplier. Overall U-Factor, SHGC, and VT Matricies are based on the standard NFRC specimen size of 1200mm wide by 1500mm high (47-1/4" by 59-1/16"). SHGC Matrix 2 Visible Transmittance 2 Glass SHGC 3 Overall SHGC 4 Glass VT 3 Overall VT 4 0.75 0.66 0.75 0.65 0.70 0.61 0.70 0.61 0.65 0.57 0.65 0.57 0.60 0.53 0.60 0.52 0.55 0.48 0.55 0.48 0.50 0.44 0.50 0.44 0.45 0.40 0.45 0.39 0.40 0.35 0.40 0.35 0.35 0.31 0.35 0.30 0.30 0.27 0.30 0.26 0.25 0.22 0.25 0.22 0.20 0.18 0.20 0.17 0.15 0.13 0.15 0.13 0.10 0.09 0.10 0.09 0.05 0.05 0.05 0.04 ADME130EN kawneer.com © Kawneer Company, Inc., 2014 Overall U-Factor 4 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. Glass U-Factor 3 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 38 AATM 6400/6500/6600 Thermal Window MAY, 2016 EC 97911-097 THERMAL CHARTS FIXED WINDOW WITH 1-3/4" TRIPE GLAZING Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. Note: Values in parentheses are metric. COG = Center of Glass. Charts are generated per AMMA 507 System U-factor vs Percent of Glass Area COG U-factor Btu hr • ft2 • °F System U-factor 0.30 (1.71) 0.28 (1.59) 0.26 (1.48) 0.22 (1.25) 0.20 (1.14) 0.18 (1.02) 0.16 (0.91) 0.14 (0.79) 0.12 (0.68) 0.10 (0.57) © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 0.24 (1.37) Percent of Glass Area = Vision Area/Total Area Daylight Opening / Projected Area Notes for System U-factor, SHGC and VT charts: For glass values that are not listed, linear interpolation is permitted. Glass properties are based on center of glass values and are obtained from your glass supplier. kawneer.com ADME130EN 39 COG SHGC COG VT Vision Area / Total Area (%) ADME130EN kawneer.com © Kawneer Company, Inc., 2014 THERMAL CHARTS Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. System SHGC AATM 6400/6500/6600 Thermal Window Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. System VT 40 EC 97911-097 MAY, 2016 FIXED WINDOW WITH 1-3/4" TRIPE GLAZING System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area Vision Area / Total Area (%) System Visible Transmittance (VT) vs Percent of Vision Area AATM 6400/6500/6600 Thermal Window MAY, 2016 EC 97911-097 THERMAL PERFORMANCE MATRIX (NFRC SIZE) FIXED WINDOW WITH 1-3/4" TRIPLE GLAZING Thermal Transmittance 1 (BTU/hr • ft 2 • °F) Overall U-Factor 4 0.30 0.35 0.28 0.34 0.26 0.32 0.24 0.30 0.22 0.29 0.20 0.27 0.18 0.25 0.16 0.24 0.14 0.22 0.12 0.20 0.10 0.19 NOTE:For glass values that are not listed, linear interpolation is permitted. 1. 2. 3. 4. SHGC Matrix 2 © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. Glass U-Factor 3 kawneer.com 41 U-Factors are determined in accordance with NFRC 100. SHGC and VT values are determined in accordance with NFRC 200. Glass properties are based on center of glass values and are obtained from your glass supplier. Overall U-Factor, SHGC, and VT Matricies are based on the standard NFRC specimen size of 1200mm wide by 1500mm high (47-1/4" by 59-1/16"). Visible Transmittance 2 Glass SHGC 3 Overall SHGC 4 Glass VT 3 Overall VT 4 0.75 0.65 0.75 0.65 0.70 0.61 0.70 0.61 0.65 0.57 0.65 0.56 0.60 0.52 0.60 0.52 0.55 0.48 0.55 0.48 0.50 0.44 0.50 0.43 0.45 0.39 0.45 0.39 0.40 0.35 0.40 0.35 0.35 0.31 0.35 0.30 0.30 0.26 0.30 0.26 0.25 0.22 0.25 0.22 0.20 0.18 0.20 0.17 0.15 0.13 0.15 0.13 0.10 0.09 0.10 0.09 0.05 0.05 0.05 0.04 ADME130EN AATM 6400/6500/6600 Thermal Window MAY, 2016 EC 97911-097 THERMAL CHARTS CASEMENT/PROJECT-IN WINDOW WITH 1" GLAZING Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. Note: Values in parentheses are metric. COG = Center of Glass. Charts are generated per AMMA 507 System U-factor vs Percent of Glass Area COG U-factor 0.47 (2.67) 0.46 (2.61) 0.44 (2.50) 0.42 (2.39) 0.40 (2.27) 0.36 (2.05) 0.34 (1.93) 0.32 (1.82) 0.30 (1.71) 0.28 (1.59) 0.26 (1.48) 0.24 (1.37) 0.22 (1.25) 0.20 (1.14) 0.18 (1.02) 0.16 (0.91) 0.14 (0.79) 0.12 (0.68) 0.10 (0.57) Percent of Glass Area = Vision Area/Total Area Daylight Opening / Projected Area Notes for System U-factor, SHGC and VT charts: For glass values that are not listed, linear interpolation is permitted. Glass properties are based on center of glass values and are obtained from your glass supplier. ADME130EN kawneer.com © Kawneer Company, Inc., 2014 0.38 (2.16) Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Btu hr • ft2 • °F System U-factor 42 System VT © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. System SHGC Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. MAY, 2016 kawneer.com AATM 6400/6500/6600 Thermal Window EC 97911-097 Vision Area / Total Area (%) ADME130EN 43 THERMAL CHARTS CASEMENT/PROJECT-IN WINDOW WITH 1" GLAZING System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area COG SHGC Vision Area / Total Area (%) System Visible Transmittance (VT) vs Percent of Vision Area COG VT AATM 6400/6500/6600 Thermal Window MAY, 2016 EC 97911-097 THERMAL PERFORMANCE MATRIX (NFRC SIZE) Thermal Transmittance 1 (BTU/hr • ft 2 • °F) 0.48 0.54 0.46 0.53 0.44 0.52 0.42 0.51 0.40 0.49 0.38 0.48 0.36 0.47 0.34 0.46 0.32 0.45 0.30 0.44 0.28 0.42 0.26 0.41 0.24 0.40 0.22 0.39 0.20 0.38 0.18 0.36 0.16 0.35 0.14 0.34 0.12 0.33 0.10 0.32 CASEMENT/PROJECT-IN WINDOW WITH 1" GLAZING NOTE:For glass values that are not listed, linear interpolation is permitted. 1. 2. 3. 4. U-Factors are determined in accordance with NFRC 100. SHGC and VT values are determined in accordance with NFRC 200. Glass properties are based on center of glass values and are obtained from your glass supplier. Overall U-Factor, SHGC, and VT Matricies are based on the standard NFRC specimen size of 1500mm wide by 600mm high (59-1/16" by 23-5/8"). SHGC Matrix 2 Visible Transmittance 2 Glass SHGC 3 Overall SHGC 4 Glass VT 3 Overall VT 4 0.75 0.48 0.75 0.47 0.70 0.45 0.70 0.43 0.65 0.42 0.65 0.40 0.60 0.39 0.60 0.37 0.55 0.36 0.55 0.34 0.50 0.33 0.50 0.31 0.45 0.30 0.45 0.28 0.40 0.26 0.40 0.25 0.35 0.23 0.35 0.22 0.30 0.20 0.30 0.19 0.25 0.17 0.25 0.16 0.20 0.14 0.20 0.12 0.15 0.11 0.15 0.09 0.10 0.08 0.10 0.06 0.05 0.05 0.05 0.03 ADME130EN kawneer.com © Kawneer Company, Inc., 2014 Overall U-Factor 4 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. Glass U-Factor 3 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 44 AATM 6400/6500/6600 Thermal Window MAY, 2016 EC 97911-097 THERMAL CHARTS CASEMENT/PROJECT-IN WINDOW WITH 1-3/4" TRIPE GLAZING Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. Note: Values in parentheses are metric. COG = Center of Glass. Charts are generated per AMMA 507 System U-factor vs Percent of Glass Area COG U-factor Btu hr • ft2 • °F System U-factor 0.30 (1.71) 0.28 (1.59) 0.24 (1.37) 0.22 (1.25) 0.20 (1.14) 0.18 (1.02) 0.16 (0.91) 0.14 (0.79) 0.12 (0.68) © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 0.26 (1.48) 0.10 (0.57) Percent of Glass Area = Vision Area/Total Area Daylight Opening / Projected Area Notes for System U-factor, SHGC and VT charts: For glass values that are not listed, linear interpolation is permitted. Glass properties are based on center of glass values and are obtained from your glass supplier. kawneer.com ADME130EN 45 COG SHGC COG VT Vision Area / Total Area (%) ADME130EN kawneer.com © Kawneer Company, Inc., 2014 THERMAL CHARTS Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. System SHGC AATM 6400/6500/6600 Thermal Window Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. System VT 46 EC 97911-097 MAY, 2016 CASEMENT/PROJECT-IN WINDOW WITH 1-3/4" TRIPE GLAZING System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area Vision Area / Total Area (%) System Visible Transmittance (VT) vs Percent of Vision Area AATM 6400/6500/6600 Thermal Window MAY, 2016 EC 97911-097 THERMAL PERFORMANCE MATRIX (NFRC SIZE) CASEMENT/PROJECT-IN WINDOW WITH 1-3/4" TRIPE GLAZING Thermal Transmittance 1 (BTU/hr • ft 2 • °F) Overall U-Factor 4 0.30 0.41 0.28 0.40 0.26 0.39 0.24 0.38 0.22 0.36 0.20 0.35 0.18 0.34 0.16 0.33 0.14 0.32 0.12 0.31 0.10 0.29 NOTE:For glass values that are not listed, linear interpolation is permitted. 1. 2. 3. 4. SHGC Matrix 2 © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. Glass U-Factor 3 kawneer.com 47 U-Factors are determined in accordance with NFRC 100. SHGC and VT values are determined in accordance with NFRC 200. Glass properties are based on center of glass values and are obtained from your glass supplier. Overall U-Factor, SHGC, and VT Matricies are based on the standard NFRC specimen size of 1500mm wide by 600mm high (59-1/16" by 23-5/8"). Visible Transmittance 2 Glass SHGC 3 Overall SHGC 4 Glass VT 3 Overall VT 4 0.75 0.48 0.75 0.46 0.70 0.45 0.70 0.43 0.65 0.41 0.65 0.40 0.60 0.38 0.60 0.37 0.55 0.35 0.55 0.34 0.50 0.32 0.50 0.31 0.45 0.29 0.45 0.28 0.40 0.26 0.40 0.25 0.35 0.23 0.35 0.21 0.30 0.20 0.30 0.18 0.25 0.17 0.25 0.15 0.20 0.14 0.20 0.12 0.15 0.11 0.15 0.09 0.10 0.08 0.10 0.06 0.05 0.05 0.05 0.03 ADME130EN AATM 6400/6500/6600 Thermal Window MAY, 2016 EC 97911-097 THERMAL CHARTS CASEMENT/PROJECT-OUT WINDOW WITH 1" GLAZING Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. Note: Values in parentheses are metric. COG = Center of Glass. Charts are generated per AMMA 507 System U-factor vs Percent of Glass Area COG U-factor 0.47 (2.67) 0.46 (2.61) 0.44 (2.50) 0.42 (2.39) 0.40 (2.27) 0.36 (2.05) 0.34 (1.93) 0.32 (1.82) 0.30 (1.71) 0.28 (1.59) 0.26 (1.48) 0.24 (1.37) 0.22 (1.25) 0.20 (1.14) 0.18 (1.02) 0.16 (0.91) 0.14 (0.79) 0.12 (0.68) 0.10 (0.57) Percent of Glass Area = Vision Area/Total Area Daylight Opening / Projected Area Notes for System U-factor, SHGC and VT charts: For glass values that are not listed, linear interpolation is permitted. Glass properties are based on center of glass values and are obtained from your glass supplier. ADME130EN kawneer.com © Kawneer Company, Inc., 2014 0.38 (2.16) Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Btu hr • ft2 • °F System U-factor 48 System VT © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. System SHGC Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. MAY, 2016 kawneer.com AATM 6400/6500/6600 Thermal Window EC 97911-097 Vision Area / Total Area (%) ADME130EN 49 THERMAL CHARTS CASEMENT/PROJECT-OUT WINDOW WITH 1" GLAZING System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area COG SHGC Vision Area / Total Area (%) System Visible Transmittance (VT) vs Percent of Vision Area COG VT AATM 6400/6500/6600 Thermal Window MAY, 2016 EC 97911-097 THERMAL PERFORMANCE MATRIX (NFRC SIZE) Thermal Transmittance 1 (BTU/hr • ft 2 • °F) 0.48 0.56 0.46 0.55 0.44 0.54 0.42 0.53 0.40 0.52 0.38 0.51 0.36 0.50 0.34 0.50 0.32 0.49 0.30 0.48 0.28 0.47 0.26 0.46 0.24 0.45 0.22 0.44 0.20 0.43 0.18 0.42 0.16 0.41 0.14 0.40 0.12 0.39 0.10 0.38 CASEMENT/PROJECT-OUT WINDOW WITH 1" GLAZING NOTE:For glass values that are not listed, linear interpolation is permitted. 1. 2. 3. 4. U-Factors are determined in accordance with NFRC 100. SHGC and VT values are determined in accordance with NFRC 200. Glass properties are based on center of glass values and are obtained from your glass supplier. Overall U-Factor, SHGC, and VT Matricies are based on the standard NFRC specimen size of 600mm wide by 1500mm high (23-5/8" by 59-1/16"). SHGC Matrix 2 Visible Transmittance 2 Glass SHGC 3 Overall SHGC 4 Glass VT 3 Overall VT 4 0.75 0.41 0.75 0.38 0.70 0.38 0.70 0.36 0.65 0.36 0.65 0.33 0.60 0.33 0.60 0.31 0.55 0.31 0.55 0.28 0.50 0.28 0.50 0.26 0.45 0.25 0.45 0.23 0.40 0.23 0.40 0.21 0.35 0.20 0.35 0.18 0.30 0.18 0.30 0.15 0.25 0.15 0.25 0.13 0.20 0.13 0.20 0.10 0.15 0.10 0.15 0.08 0.10 0.07 0.10 0.05 0.05 0.05 0.05 0.03 ADME130EN kawneer.com © Kawneer Company, Inc., 2014 Overall U-Factor 4 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. Glass U-Factor 3 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 50 AATM 6400/6500/6600 Thermal Window MAY, 2016 EC 97911-097 THERMAL CHARTS CASEMENT/PROJECT-OUT WINDOW WITH 1-3/4" TRIPE GLAZING Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. Note: Values in parentheses are metric. COG = Center of Glass. Charts are generated per AMMA 507 System U-factor vs Percent of Glass Area Btu hr • ft2 • °F System U-factor COG U-factor 0.30 (1.71) 0.28 (1.59) 0.24 (1.37) 0.22 (1.25) 0.20 (1.14) 0.18 (1.02) 0.16 (0.91) 0.14 (0.79) 0.12 (0.68) 0.10 (0.57) © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 0.26 (1.48) Percent of Glass Area = Vision Area/Total Area Daylight Opening / Projected Area Notes for System U-factor, SHGC and VT charts: For glass values that are not listed, linear interpolation is permitted. Glass properties are based on center of glass values and are obtained from your glass supplier. kawneer.com ADME130EN 51 COG SHGC System Visible Transmittance (VT) vs Percent of Vision Area COG VT Vision Area / Total Area (%) ADME130EN kawneer.com © Kawneer Company, Inc., 2014 THERMAL CHARTS Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. System SHGC AATM 6400/6500/6600 Thermal Window Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. System VT 52 EC 97911-097 MAY, 2016 CASEMENT/PROJECT-OUT WINDOW WITH 1-3/4" TRIPE GLAZING System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area Vision Area / Total Area (%) AATM 6400/6500/6600 Thermal Window MAY, 2016 EC 97911-097 THERMAL PERFORMANCE MATRIX (NFRC SIZE) CASEMENT/PROJECT-OUT WINDOW WITH 1-3/4" TRIPE GLAZING Thermal Transmittance 1 (BTU/hr • ft 2 • °F) Overall U-Factor 4 0.30 0.45 0.28 0.45 0.26 0.44 0.24 0.43 0.22 0.42 0.20 0.41 0.18 0.40 0.16 0.39 0.14 0.38 0.12 0.37 0.10 0.36 NOTE:For glass values that are not listed, linear interpolation is permitted. 1. 2. 3. 4. SHGC Matrix 2 © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. Glass U-Factor 3 kawneer.com 53 U-Factors are determined in accordance with NFRC 100. SHGC and VT values are determined in accordance with NFRC 200. Glass properties are based on center of glass values and are obtained from your glass supplier. Overall U-Factor, SHGC, and VT Matricies are based on the standard NFRC specimen size of 600mm wide by 1500mm high (23-5/8" by 59-1/16"). Visible Transmittance 2 Glass SHGC 3 Overall SHGC 4 Glass VT 3 Overall VT 4 0.75 0.40 0.75 0.38 0.70 0.38 0.70 0.36 0.65 0.35 0.65 0.33 0.60 0.33 0.60 0.30 0.55 0.30 0.55 0.28 0.50 0.28 0.50 0.25 0.45 0.25 0.45 0.23 0.40 0.22 0.40 0.20 0.35 0.20 0.35 0.18 0.30 0.17 0.30 0.15 0.25 0.15 0.25 0.13 0.20 0.12 0.20 0.10 0.15 0.10 0.15 0.08 0.10 0.07 0.10 0.05 0.05 0.05 0.05 0.03 ADME130EN Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. AATM 6400/6500/6600 Thermal Window BLANK PAGE ADME130EN kawneer.com © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 54 EC 97911-097 MAY, 2016