Datasheet

Series DX
3A to 60 Vdc
DIN Rail Relay AC/DC Control
Part Number
Description
DX6R3E-02
3A, 60 Vdc
DX6R3U-02
3A, 60 Vdc
Part Number Explanation
DX
6
R
3
-02
E
Control Range4
Series
Switch Type2
Feature4
Line Voltage1
Output Current – Amps
NOTES
1) Line Voltage (nominal) 6 = 60 Vdc
2) Switch Type: R = Random turn-on
3) Control Range: E = 5-30 Vdc (3-30 Vdc for DX6R3E-02);
U = 90-240 Vac
4) Feature: 02 = With LED
MECHANICAL SPECIFICATION
+ -
input
VAC
3.01
(0.002)
3.01
input
VAC
0.002
1.14 (29)
0.002
2.09
(53)
0.001
.48 (12.2)
WEIGHT: 1.06 oz (30g)
DX22R1E-02
DX6R3E-02
DESCRIPTION
The Series DX relays are designed for DIN-rail
mounting. These solid-state relays include a control
LED that provides visual control status. The tight
zerocross window significantly reduces EMI. Its
compact size and user friendly package make the
Series DX relay an excellent choice for designers.
(0.002)
(76.4)
(76.4)
2-60VDC
3A
2-60VDC
3A
FEATURES/BENEFITS
• New generation of solid-state relays for DIN rail
mounting
• Control visualization by LED
• AC/DC control
• High immunity to surges
0.001
.68
(17.2)
APPLICATIONS
• Interface applications
• Vending machines
• Light/lamp control
• Contactor driver
• Fan speed control
• HVAC controls
DX6R3U-02
Figure 1 — DX relays, dimensions in inches (mm)
TYPICAL APPLICATION
+
1+
BLOCK DIAGRAM
3
1+
AC/DC
2–
2–
(*)
Load
4
Figure 3 — DX relays
–
Figure 2 — DX relays
© 2014 TELEDYNE RELAYS
(800) 284-7007 • www.teledynerelays.com
DX Page 1
DX\072014\Q3
Series DX
3A to 60 Vdc
DIN Rail Relay AC/DC Control
INPUT (CONTROL) SPECIFICATION
Min
THERMAL CURVES
Max
Units
6
Control Range
See input voltage range
3
30
Vdc
DX6R3U-02
90
240
Vac/dc
Input Current Range
DX6R3E-02
1
30
mA
DX6R3U-02
2
5.7
mA
5
Load Current (Arms)
DX6R3E-02
Vco
ntro
lm
in
Vco
ntro
l ma
x
4
3
DX6
2
1
Must Turn-Off Voltage
DX6R3E-02
1
Vdc
DX6R3U-02
15
Vac/dc
0
10
20
30
40
50
60
70
80
90
100
Ambient Temperature (qC)
Input Resistance (Typical)
DX6R3E-02
600
Ohms
DX6R3U-02
41,000
Ohms
ENVIRONMENTAL SPECIFICATION
Min
Max
Units
Operating Temperature
-40
80
°C
Storage Temperature
-40
105
ºC
Input-Output Isolation
2500
OUTPUT (LOAD) SPECIFICATION
Operating Range
Min
Max
Units
2
60
V
60
V
3
A
1.6
V
Peak Voltage
Input-Output Capacity
Load Current Range
.003
On-State Voltage Drop
Vrms
8
pF
NOTES
1) Electrical specifications at 25°C unless otherwise specified
2) On inductive loads, a free-wheeling diode (or clamp) is recommended
3) For additional/custom options, contact factory.
Maximum Surge Current Rating (Non-Repetitive)
DX6R3E-02
5
Apeak
DX6R3U-02
10
Apeak
DX6R3E-02
0.3
mA
DX6R3U-02
1
mA
Turn-On Time
0.2
ms
Turn-Off Time
0.8
ms
Off-State Leakage Current (60Hz)
Off-State dv/dt
Switching Frequency
DX Page 2
200
V/μs
500
Hz
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE
© 2014 TELEDYNE RELAYS
DX\072014\Q3