Series AS4 4A to 460 Vac SIP Package DC Control Part Number Description AS24D4E/R 4A, 275 Vac AS46D4E 4A, 460 Vac Part Number Explanation AS Series 46 D 4 E Control Range3 Switch Type2 Line Voltage Output Current – Amps 1 FEATURES/BENEFITS NOTES 1) Line Voltage (nominal): 46 = 460 Vac 2) Switch Type: D = Zero-cross turn-on 3) Control Range: E = 4–30 Vdc (5-30 Vdc for AS60D4E) 4) RoHS Compliant = /R (AS24D4E/R) • Industry standard package • Tight zero-cross window for low EMI • Low input current draw • High dv/dt capability • Integral transient voltage protection • High immunity to surges MECHANICAL SPECIFICATION Bottom View .30 (7.62) .39 (10.2) .10 (2.58) .39 (10.2) 1.70 (43.2) input 4-30 Vdc 4- 3+ .30 (7.63) 50A2s output 230 Vac 4A 2 1 1.0 (25.4) .19 (6.5) Ø1 .49 .40 (12.7) (10.16) .20 (5.08) DESCRIPTION The AS 4-amp solid-state single inline (SIP) four-pin relays are designed for mounting on a printed circuit board. The relays offer built-in voltage protection and can withstand very high current overloads. The Series AS4 relays have a low zero-cross window. The compact size and triac output make the AS relay the perfect retrofit for electromechanical relays. .30 (7.62) APPLICATIONS • Interface applications • Vending machines • Light/lamp control • HVAC controls APPROVALS UL File Number: E128555. WEIGHT: 1.06 oz. (30g) Figure 1 — AS relays; dimensions in inches (mm) BLOCK DIAGRAM (Control LED available on AS46R4F-02 only.) ELECTRICAL SPECIFICATIONS Min Max Units Operating Temperature -40 80 °C Storage Temperature -40 120 °C Input-Output Isolation 4000 Input-Output Capacitance © 2014 TELEDYNE RELAYS Vrms 3 Figure 2a — All AS relays except AS60D4E pF (800) 284-7007 • www.teledynerelays.com AS4 Page 1 AS4\042014\Q2 Series AS4 4A to 460 Vac SIP Package DC Control INPUT (CONTROL) SPECIFICATIONS Min Max OUTPUT (LOAD) SPECIFICATIONS Units Control Range Min Max Units Operating Range AS24D4E/R 4 30 Vdc AS24D4E/R 12 275 Vrms AS46D4E 4 30 Vdc AS46D4E 12 460 Vrms Input Current Range Peak Voltage (Clamping Voltage) AS24D4E/R 3 30 mA AS24D4E/R 600(450) Vpeak AS46D4E 3 30 mA AS46D4E 900(720) Vpeak Must Turn-Off Voltage Load Current Range AS24D4E/R 0.8 Vdc AS46D4E 0.8 Vdc .005 4 Arms Maximum Surge Current Rating (Non-Repetitive) (See Figure 5a and Figure 5b Input Resistance (Typical) AS24D4E/R 1,000 Ohms AS46D4E 1,000 Ohms AS24D4E/R 100 Apeak AS46D4E 100 Apeak 1.6 V AS24D4E/R ±12 V AS46D4E ±12 V AS24D4E/R 0.3 mArms AS46D4E 0.3 mArms Turn-On Time (60Hz) 8.3 ms AS24D4E/R 8.3 ms AS46D4E 8.3 ms 8.3 ms On-State Voltage Drop TYPICAL APPLICATION L1 L1 Zero-Cross Window (Typical) Off-State Leakage Current (60Hz) )LJXUHD Turn-Off Time (60Hz) Off-State dv/dt 500 Operating Frequency 10 V/ųs 440 Hz AS24D4E/R 50 A²S AS46D4E 50 A²S I²T for Match Fusing (<8.3ms) AS4 Page 2 SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE © 2014 TELEDYNE RELAYS AS4\042014\Q2 Series AS4 4A to 460 Vac SIP Package DC Control Load Current (Arms) LOAD CURRENT DERATING CURVE Ambient Temperature (C) Figure 4 — Thermal curves Overload Current (A) SURGE CURRENT RATING Number of Cycles Figure 5a — Non-repetitive surge current NOTES: 1. Electrical specifications at 25C unless otherwise specified. 2. For 800Hz applications, contact factory. 3. For additional/custom options, contact factory. © 2014 TELEDYNE RELAYS (800) 284-7007 • www.teledynerelays.com AS4 Page 3 AS4\042014\Q2 Series AS4 4A to 460 Vac SIP Package DC Control PEAK CURRENT (Apk) 400 350 300 250 200 150 1 2 100 50 0.01 0.1 1 PEAK CURRENT (Apk) SURGE CURRENT 250 200 150 No repetive surge current without voltage reapplied. 100 1 2 50 Repetive surge current with voltage reapplied. 0 0.01 10 0.1 1 TIME (s) TIME (s) Figure 4c — 35A output current Figure 4b — 25A output current 10 THERMAL CURVES Power Dissipation (W) 1K/W 1,5K/W duty cycle 90% 45 40 50 40 Full on State 35 35 3K/W 30 30 50% on State 25 4K/W 25 20 20 6K/W 15 15 10 10 12K/W 5 0 5 10 15 20 25 30 35 40 45 50 2K/W 0 0 10 20 30 40 50 60 70 80 90 100 1,5K/W 1K/W 30 duty cycle 90% 3K/W 25 Full on State 25 4K/W 20 20 6K/W 15 15 10 10 12K/W 5 5 50% on State 5 I max = 48A @ Tcase = 85°C I max = 34A @ Tcase = 100°C 0 30 45 2K/W Power Dissipation (W) 50 0 0 5 10 15 20 25 0 0 10 20 30 40 50 60 70 80 90 100 Load Current (A) Load Current (A) Figure 5c — 35A output power Figure 5b — 25A output power 12°C/W corresponds to a relay without heat sink 6°C/W corresponds to a relay mounted on a DIN-rail adaptor (Teledyne P/N DL12) AS4 Page 4 SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE © 2014 TELEDYNE RELAYS AS4\042014\Q2