ETC EFRQ600240R55-026

Home
TELEDYNE RELAYS
NEW! EFRQ Series
Industrial Solid State Products
QUAD SCR OUTPUTS TO 55 AMPS PER OUTPUT, 1200 VOLTS
PART NUMBERS
Package &
Chip Type
Max Blocking Input Type
Voltage (piv)/
Line Rating
EFRQ-SCR
1200480
600240
D-DC Input
Zero Cross
Switching
R-DC Input,
Random
Turn-On
Output
Current
Amps
Options
25
40
55
See Table
Below and
Page 58
FEATURES/BENEFITS
•
•
Options (Add Suffix to Part Number) - See Page 58 for full description
•
-012
EZ MountTM
-026
Non-Floating Output Terminals
•
Part Number Example: EFRQ120480D55
•
MECHANICAL SPECIFICATION
.739
(18.77)
Control In 3-32V
M5 SCREW /
NUT
.250 TYP.
(6.35)
.160
(4.06)
.160 DIA.
(4.06)
(+COM) (1)— (2)— (3)— (4)—
.825
(20.96)
A1
B1
TELEDYNE RELAYS
2.50
1.20 (63.5)
(30.5)
TM
POWERTHERM
L1
.825
(20.96)
L2
•
•
EFRQ Series
A2
B2
.650
(16.51)
.420
(10.67)
2.500
(63.5)
3.60
(91.44)
TYPICAL APPLICATIONS
•
.758
(19.3)
.200
(5.08)
•
4.00
(101.6)
BLOCK DIAGRAM
(1)
A1
OPTO
ISOLATED
CONTROL
DETECTION/
CONTROL
CIRCUIT
AC OUTPUT A
L1
(2)
OPTO
ISOLATED
CONTROL
DETECTION/
CONTROL
CIRCUIT
AC OUTPUT B
A2
B2
(3)
OPTO
ISOLATED
CONTROL
DETECTION/
CONTROL
CIRCUIT
AC OUTPUT C
L2
(4)
OPTO
ISOLATED
CONTROL
(+ COM)
page 32
DETECTION/
CONTROL
CIRCUIT
Four independently controlled solid state
relays in a single package.
Screw type power terminals in a high
temperature plastic housing for mechanical
ruggedness.
Constant Current Input minimizes source
current requirement (standard on D input
only)
Exposed ceramic baseplate for reduced
thermal resistance and best thermal
performance.
Constructed using Teledyne’s unique
PowerthermTM process. This process yields
superior thermal impedance and power
cycling capabilities through reduced thermal
interconnections, allowing for cooler, more
reliable operation.
The logic drive circuitry section uses the
latest in reliable surface mount technology.
Certifications:
- UL and ULC Recognized File #E128555
- CE # EN60947-1
•
•
•
•
•
•
On/Off controls of medium power AC
equipment.
Interfacing of microprocessor controls to AC
loads - lights, motors, heaters, valves,
solenoids etc.
Electromechanical line relay replacement.
Mercury displacement relay replacement.
Industrial and Process Controls.
Programmable Controller interface.
Robotics motor position and speed controls.
Light dimmers; Transformer tap switch.
GENERAL DESCRIPTION
The EFRQ series 4-pole AC Solid State Relays are
designed to save space while providing independent
control of large amounts of power in four separate
circuits. Optical isolation ensures complete protection
of each relay’s circuit control elements from load
transients in each load circuit. Teledyne’s advanced
design featuring the PowerthermTM process offers
users superior thermal management resulting in
excellent performance, quality and reliability.
AC OUTPUT D
B1
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE.
Updated 9/24/99
Home
TELEDYNE RELAYS
NEW! EFRQ Series
Industrial Solid State Products
QUAD SCR OUTPUTS TO 55 AMPS PER OUTPUT, 1200 VOLTS
ELECTRICAL SPECIFICATIONS
INPUT (CONTROL) SPECIFICATIONS
Parameter
Input Type
Control Voltage Range
Input Current
OUTPUT (LOAD) SPECIFICATIONS (Contd)
Min
Max
Units
D
3
32
Vdc
R
4
26
15
D,R(@5Vdc)
Must Turn-Off Voltage
D,R
Reverse Voltage Protection
D,R
Turn-Off Current
D,R
1
mA
Parameter
Output Current Min
Max
Output Current Rating
25
0.05
25
Per Output
40
0.05
40
(Load Current @85 °C)
55
0.05
55
Surge Current Rating
25
250
See Fig 1 (Non-
40
400
Repetitive 16.7 mS)
55
600
Thermal Resistance
25
.40
Junction to Case (JC)
40
0.35
55
0.35
Units
A
Vdc
-32
0.25
Vdc
mA(DC)
A
OUTPUT (LOAD) SPECIFICATION
Load Voltage Rating
Voltage Code
600240
1200480
Frequency Range (Note 2)
Over Voltage Range
On-State Voltage Drop
Min
24
Max
280
48
530
47
400
600240
600
1200480
1200
SCR Output
1.4
Units
Vac
VPeak
D
8.3
ms
0.02
ms
Turn-Off Time
8.3
ms
Leakage Current (Off-State)
0.5
mA
500
V/µs
4000
V
@25 °C
Isolation (All Terminals
To Heatsink) = VRMS
For 1 Min With Unit
Mounted Properly
Operating Temperature
-40
125
Power Factor Range
0.5
1.0
Updated 9/24/99
FIGURE 1 Max Non-Repetitive Surge Current
V
R
dV/dt (Typical)
°C/W
Hz
@ Max Rate Current
Turn-On Time
Per Contact
Max On-State Surge Current (Amps RMS)
Parameter
250
1
10
100
Number of Equal Amplitude Current Pulses at 60Hz
°C
NOTES:
1.)
Where overvoltage transient spikes are present,
suppression may be required. An MOV suppressor and/or
a snubber circuit across the AC terminals of the module
will provide additional transient immunity.
2.)
For 400 Hz inductive load, contact factory.
3.)
Curve for 25 amp output shown. Contact factory for other
outputs.
Industrial Solid State Products • 800-436-8766 • www.teledynerelays.com
page 33