Datasheet

Series RF255/RF257
Magnetic-Latching
High Power, RF Relay
MAGNETIC-LATCHING
DPDT HALF-SIZE
CRYSTAL CAN
HIGH POWER RF RELAY
DC-3 GHZ
SERIES
RELAY TYPE
RF255
Commercial Magnetic-Latching, DPDT, High Power, Half-Size Crystal Can Relay
RF257
Commercial Magnetic-Latching, DPDT, High Power, Half-Size Crystal Can Relay
DESCRIPTION
The Series RF255 is an industry-standard, half-size,
latching crystal can relay. These relays are highly
suitable for high RF power applications (RF Power
Handling) and other RF circuits, the RF255/RF257
features:
• High repeatability
• Broad Bandwidth
• Metal enclosure for EMR shielding
• Highly resistant to ESD
Teledyne Relays’ Series RF255 offers:
• All welded construction
• Wire leads, gold plated or solder-coated
• Matched seal for superior hermeticity
• Gold-plated contact assembly
• Modernized assembly process
• Advanced cleaning techniques
The RF257 is a variation of the RF255 featuring a different schematic.
SCHEMATIC DIAGRAM
RF255
B3
RF257
A2
A1
B3
A2
X1
Y2
Y1
B1
A1
X1
Y2
X2
X2
Y1
B2
A3
B1
B2
A3
As viewed from terminals
(Pin numbers are for reference only, not marked on relay)
ENVIRONMENTAL AND
PHYSICAL SPECIFICATIONS
Temperature
(Ambient)
Storage
–65°C to +125°C
Operating
–55°C to +85°C
Vibration
(General Note 1)
10 g’s 10 to 500 Hz
Shock
(General Note 2)
30 g’s,
6ms half sine
Enclosure
Hermetically sealed
Weight
0.46 oz. (13g) max.
© 2012 TELEDYNE RELAYS
INTERNAL CONSTRUCTION
(800) 284-7007 • www.teledynerelays.com
RF255/RF257 Page 1
RF255\RF257\062012\Q2\
Series RF255/RF257
Magnetic-Latching
High Power, RF Relay
SERIES RF255/RF257
TYPICAL RF CHARACTERISTICS (See RF Notes)
VSWR Between Contacts (RF Note 6)
3
2.8
2.6
2.4
VSWR
2.2
2
1.8
1.6
1.4
1.2
1
0
0.5
1
1.5
2
2.5
3
Frequency ( GHz )
Insertion Loss Across Contacts (RF Note 6)
0
-0.5
Insertion Loss ( dB )
-1
-1.5
-2
-2.5
-3
0
0.5
1
1.5
2
2.5
3
Frequency ( GHz )
Isolation Across Contacts (RF Note 4)
Isolation Pole-to-Pole
0
0
-10
-10
-20
Isolation ( dB )
Isolation ( dB )
-20
-30
-30
-40
-50
-40
-60
-70
-50
0
0.5
1
1.5
Frequency ( GHz )
2
2.5
3
0
0.5
1
1.5
2
2.5
3
Frequency ( GHz )
RF NOTES
1.
2.
3.
4.
5.
6.
7.
Test conditions:
Fixture: .031" copper clad, reinforced PTFE, RT/duroid® 6002 with SMA connectors.
(RT/duroid® is a registered trademark of Rogers Corporation.)
b. Room ambient temperature.
c. Terminals not tested were terminated with 50-ohm load.
d. Contact signal level: –10 dBm.
e. No. of test samples: 4.
Data presented herein represents typical characteristics and is not intended for use as specification limits.
Data is per pole, except for pole-to-pole data.
Data is the average from readings taken on all open contacts.
Data is the average from readings taken on poles with de-energized.
Data is the average from readings taken on all closed contacts.
Test fixture effect de-embedded from frequency response data.
RF255/RF257 Page 2
a.
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE
© 2012 TELEDYNE RELAYS
RF255\RF257\062012\Q2
Series RF255/RF257
Magnetic-Latching
High Power, RF Relay
SERIES RF255/RF257
TYPICAL RF CHARACTERISTICS (See RF Notes)
RF255/RF257 RF POWER HANDLING CAPABILITY
1000
Hot Switched
Carry
RF POWER, Watts
300
200
100
10
1
1
10
100
1,000
3,000
FREQUENCY, MHz
Test Notes:
1. Test condition: Ambient temperature and pressure
2. Hot switched cycle rate: 1/3 Hz
3. Matched load: 1.2:1 maximum
© 2012 TELEDYNE RELAYS
(800) 284-7007 • www.teledynerelays.com
RF255/RF257 Page 3
RF255\RF257\062012\Q2\
Series RF255/RF257
Magnetic-Latching
High Power, RF Relay
SERIES RF255/RF257
GENERAL ELECTRICAL SPECIFICATIONS (@ 25°C)
Contact Arrangement
2 Form C (DPDT)
Contact Resistance
Low Level: 0.050Ω maximum before life
0.150Ω maximum after life
High Level: 0.050Ω maximum before life
0.100Ω maximum after life
Low level:
Resistive:
Contact Load Rating
(Case Grounded)
10 to 50 μA @ 10 to 50 mV, 1,000,000
2A @ 28Vdc, 100,000 cycles
.15A @ 115Vac, 60 and 400Hz, 100,000 cycles
Lamp:
0.16A @ 28Vdc, 100,000 cycles
Intermediate Current: 0.1A @ 28Vdc, 50,000 cycles
Inductive:
0.75A @ 28Vdc, 200mH, 100,000 cycles
Contact Bounce
3.0 ms maximum
Contact Overload Rating
4A/28Vdc Resistive (100 cycles min.)
Operate Time
4ms maximum over the temperature range with rated coil voltage
Insulation Resistance
1,000 MΩ minimum, except the resistance between coil and case at high temperature shall be 500MΩ or greater
Between case, frame, or enclosure
and all contacts in the latched and
non-latched positions
Dielectric Strength
Sea Level
Altitude
1,000 Vrms (60Hz) 350 Vrms (60Hz)
Between case, frame, or enclosure
and coils
500 Vrms (60Hz)
Between all contacts and coils
1,000 Vrms (60Hz) 1,000 Vrms (60Hz)
Between open contacts in the latched
and non-latched positions
500 Vrms (60Hz)
1,000 Vrms (60Hz)
Between Coils
500 Vrms (60Hz)
1,000 Vrms (60Hz)
Between contact poles
1,000 Vrms (60Hz) 1,000 Vrms (60Hz)
1,000 Vrms (60Hz)
9ms @ rated voltage
Minimum Operate Pulse
DETAILED ELECTRICAL SPECIFICATIONS (@25°C)
RF255-5
RF257-5
RF255-6
RF257-6
RF255-12
RF257-12
RF255-26
RF257-26
5.0
6.7
6.0
8.0
12.0
16.0
26.5
32.0
45
63
254
1000
Min.
Max.
1.0
3.8
1.3
4.5
2.6
9.0
5.2
18.0
Min. @ 25°C
Max. @ 25°C
1.6
2.7
2.0
3.25
4.0
6.5
8.0
13.0
BASE PART NUMBERS
Coil Voltage, Nominal (Vdc)
Nom.
Max.
Coil Resistance (Ohms ±10%, 25°C)
Set/Reset Voltage
(Vdc)
Teledyne Part Numbering System for RF255/RF257
RF255
Relay Series
(Commercial)
-
12
/
Q
Lead Finish
G = .187” gold-plated wire lead
Q = .187” solder-coated wire lead
Blank = .187” gold-plated or solder-coated
wire lead (See Note 6)
Coil Voltage
5 = 5Vdc
6 = 6Vdc
12 = 12Vdc
26 = 26.5Vdc
RF255/RF257 Page 4
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE
© 2012 TELEDYNE RELAYS
RF255\RF257\062012\Q2
Series RF255/RF257
Magnetic-Latching
High Power, RF Relay
SERIES RF255/RF257
OUTLINE DIMENSIONS
RF255
B3
A2
A1
X1
Y2
X2
Y1
B2
B1
A3
RF257
B3
A2
A1
X1
Y2
X2
Y1
B1
.030 (.762)
+.003 (+.076)
–.002 (–.051)
.187 ±.020
(4.75 ±.051)
GOLD-PLATED
LEAD-FREE
.030 (.762)
+.003 (+.076)
–.002 (–.051)
.187 ±.030
(4.75 ±.051)
B2
A3
SCHEMATIC
(Coil X Last Energized)
(Bottom View)
WIRE LEAD
SOLDER COATED
(SEE PART NUMBER EXAMPLE)
GENERAL NOTES
1. Vibration (sinusoidal): MIL-STD-202, method 204, test condition D (except frequency shall be 10 to 2,500 Hz). Contact chatter
shall not exceed 10μs maximum for closed contacts, and 1μs maximum closure for open contacts. Vibration (random):
MIL-STD-202, method 214, test condition IG. Contact chatter shall not exceed 10μs maximum for closed contacts, and 1μs
maximum closure for open contacts (applicable to qualification and group C testing only).
2. Shock (half-sine pulse): MIL-STD-202, method 213, test condition C (100 g’s). Contact chatter shall not exceed 10μs maximum
for closed contacts, and 1μs maximum closure for open contacts.
3. Dimensions are in inches. Metric equivalents in parentheses for reference only.
4. Unless otherwise specified, tolerance is ±.010 (0.25mm).
5. Indicated terminal is marked with a contrasting bead.
6. Unless otherwise specified, relays will be supplied with either gold-plated or solder coated leads. The slash and characters
appearing after the slash are not marked on the relay.
7. When latching relays are installed in equipment, the latch and reset coils should not be pulsed simultaneously.
8. Each relay possesses high-level and low level capabilities. However, relays previously tested or used above 10mA resistive at
6Vdc maximum or peak ac open circuits not recommended for subsequent use in low-level applications.
9. Relays may be subjected to 260°C (1 minute) peak solder reflow temperature.
© 2012 TELEDYNE RELAYS
(800) 284-7007 • www.teledynerelays.com
RF255/RF257 Page 5
RF255\RF257\062012\Q2\