Air Flow Sensor D6FZ CSM_D6FZ_DS_E_2_3 Visualization of Compressed Air Flow Rates, Pressures, and Leakage Rates on Production Lines and Equipment • Ideal for measuring compressed air in manufacturing lines and equipment. • Can be mounted behind curved pipes. • The D6FZ-FGS1000 simultaneously measures the flow rate, leakage rate, and pressure. • The D6FZ-FGT200/500 provides easy-to-read 11-segment 8digit displays. • Data can be easily logged at an air flow station. • Many types of outputs (RS-485, analog, and pulse) to quickly enable visualization on existing systems. For the most recent information on models that have been certified for safety standards, refer to your OMRON website. Features Visualize Air Flows, Pressures, and Leakage to Save Energy on Production Sites. Consequently Visualization is required on both the supply side and consumption side. This leads to lower power consumption while maintaining quality. Power supply side Consumption side Monitor and control supply quantities Maintain production quality Optimize supply quantities Optimize usage quantities Compressed air on production line Data logging D6FZ-FGS1000 (1000L type) Compressed air at machines D6FZ-FGX21 D6FZ-FGT200/500 (200L/500L type) Identify the waste that had previously been invisible to reduce the energy consumed for compressed air. 1 D6FZ The Best Product to Measure Compressed Air on Production Lines D6FZ-FGS1000 1 2 3 Leakage Usage Pressure Pipe size: Rc1 (25A) (A bushing can be used to convert down to 15A.) Multi-sensing High Accuracy Simultaneous Measurement of Flow, Pressure, Leakage, and Temperature The Sensor provides multiple sensing functions. You can identify compressed air conditions with just one Sensor. Highly Accurate Flow Measurements High measuring accuracy of ±2% R.S. (at 50 L/min or less) is achieved. High accuracy Flow Rate Measuring Accuracy Pressure measurement 50 D6FZ-FGS (1000L/min max.) 40 Previous products (200L/min max.) 30 Flow measurement Previous products (1000L/min max.) T Temperature measurement Leakage measurement Accuracy R.S. [%] 20 10 0 -10 Measurement range 1,000 L/min max. -20 Measuring accuracy R.S. ±2.0% (at 50 L/min or less) -30 -40 -50 Simple Setup 0 50 100 150 200 00 950 1000 Flow rate [L/min] Silencer Mountable to Curved Pipes or Couplers The built-in silencer eliminates ultrasonic noise and turbulence. It eliminates the need for straight pipes to make installation work easy. * Data is based on comparison for OMRON conditions (November 2012). Check the actual application environment before using a Sensor. Flow Measurements over a Wide Range Wide range A wide measurement range of 1 to 1,000 L/min is achieved. Previous products D6FZ-FGS Straight pipe not required. Resists Oils and Mist Ultrasonic sensor Easy installation with a coupler. A straight pipe with a length that is 10 times the opening diameter is required. Main Features Built-in suppressor to suppress turbulence and eliminate noise. Two analog outputs Two pulse outputs RS-485 communications IP64 Operation indicator A built-in ultrasonic sensor is used for flow measurements. With high resistance to rusty pipes and oil flooded compressors, you can install the Sensor almost anywhere. Threshold values (peak, bottom, and leak) Alarm hold Flow Leakage Pressure Temperature measurement measurement measurement measurement Feature Comparison Curved pipe Station Multi-sensor mounting Resistant to oils and mist connection connection 2 D6FZ Ideal for Compressed Air Measurements at Machines 1 2 3 Leakage Usage Pressure D6FZ-FGT200/500 200L type 500L type Pipe size: 8A (Rc1/4) Pipe size: 15A (Rc1/2) Easy to Read High Accuracy Highly Accurate Flow Measurements First in the industry! * 11-segment 8-digit LCD An OMRON MEMS chip is used to achieve the highest accuracy in the industry* of ±2% F.S. (at 50 L/min or less). The characters are easy to read, and the total flow rate can be checked in a glance. clr Clear total flow rate With Flow ave Temperature sensor Without Flow Temperature sensor Flow Averaging count setting Display Reversal Heater element You can reverse the display direction to match the installation direction. Always use one of the specified installation directions. Note: Omron survey (as of June 2013) Leakage Measurement A high measurement accuracy of ±0.5% F.S. is achieved at a low flow rate of less than 50 L/min. This allows you to identify the air flow that is discarded as leakage when machines are not operating to save money. Press and hold to reverse. Leakage on non-working days (Saturday and Sunday) was 36 m 3! Note: According to OMRON investigation in June 2013. Specifications are the same as the 1000L type. Zero Reset Other Features You can use the zero reset to identify seasonal or day/night variations in the flow rates. Flow Straightener with Honeycomb Structure A honeycomb structure effectively straightens the flow to keep pressure loss low. Honeycomb structure Press and hold. Threshold values (peak, bottom, and leak) One analog output Peak/Bottom hold Two pulse outputs Main RS-485 communications Auto-tuning Features Key lock IP65 Display Flow Leakage Pressure Temperature measurement measurement measurement measurement Feature Comparison Curved pipe Resistant to oils Station Multi-sensor mounting g and mist connection connection 3 D6FZ Enclosed Software Easily Analyzes Logged Data You can collect onsite data at an Air Flow Station data and use the Multi Data Viewer Light software to analyze the data in your office to identify other locations for improvement on the production site. Free Enclosed software On the Production Site: Multi Data Viewer Light In the Office: This software displays data for specific time periods, such as by the minute, e, Data monitoring and storing by Air Flow Station hour, or day. The total flow rate is displayed as a bar graph and the e momentary flow rate and pressure are displayed with dotted lines, so you can n Data storing and analyzing on a computer see the overall situation at a glance. The Air Flow Station enables easy data logging. Display period is easy to change. Total flow rate (bar graph) Pressure (dotted line graph) Yo u c a n u s e c o m p a r a t i v e d i s p l a y s w i t h previously logged data. For example, side-by-side comparison of flow rates by the day for different months is possible. Save the data to an SD memory card. Check boxes allow you to display only the required data. Start data logging with a single Multi Data Viewer Light is on the enclosed utility disk (CD-ROM). press of a button. You can save energy in a variety of applications. Stop Ionizer Idling D6FZ-FGT By stopping the supply of compressed air with a solenoid valve when there is no workpiece, compressed air usage is reduced. At the same time, the Flow Sensor monitors the quantity of supplied compressed air to ensure that it is within the specified range. Therefore, the Sensor helps maintain and improve quality. Leakage Management for Machines D6FZ-FGT D6FZ-FGS Flow Management for Molding Machines D6FZ-FGT D6FZ-FGS By giving priority to the monitoring of molding machines and other machines that use large quantities of compressed air, energy is efficiently saved. D6FZ-FGS Flow and Pressure Management for Production Lines When the leak increases Upper limit During operation Lower limit Upper limit During operation When operation is stopped Lower limit leak Leak output When operation is stopped leak ON OFF Leak output ON OFF Set the leak threshold value to identify when repairs for leaks are required. Monitor consumption and pressure fluctuations for each production line to identify bottleneck lines or machines to implement onsite improvements and save energy. 4 D6FZ Specifications Units Appearance Product name Model 200L-type Air Flow Sensor D6FZ-FGT200 500L-type Air Flow Sensor D6FZ-FGT500 1000L-type Air Flow Sensor (cable length: 0.2 m) D6FZ-FGS1000 Air Flow Station (cable length: 1.5 m, including T-branch Connector cable) D6FZ-FGX21 1000L-type Air Flow Sensor Set • 1000L-type Air Flow Sensor • Air Flow Station • T-branch Connector • Cable with Connector on One End (3 m) D6FZ-FGS1000-S Options (Sold Separately) Appearance Product name Model T-branch Connector D6FZ-FC02 (D6FZ-FGT Air Flow Sensor only) Mounting Bracket • Mounting Bracket: 1 • Phillips screws (M3): 4 D6FZ-FC03 (D6FZ-FGX21 Air Flow Station only) Mounting magnets * • Mounting magnets: 2 • Phillips screws (M3): 2 ZN9-EM01-S Cable length: 3 m Cable with Connector on One End Cable with Connectors on Both Ends Cable length: 10 m D6FZ-JD3A M12 connector (8-pin) D6FZ-JD10A Cable length: 20 m D6FZ-JD20A Cable length: 3 m D6FZ-JD3B Cable length: 5 m Cable length: 10 m Cable length: 20 m M12 connector (8-pin) D6FZ-JD5B D6FZ-JD10B D6FZ-JD20B * When magnets are used, the maximum vibration resistance is 55 Hz. 5 D6FZ Ratings Air Flow Sensor Item Model D6FZ-FGT200 D6FZ-FGT500 Air or nitrogen (N2)*1 Applicable fluid Maximum working pressure 0.75 MPa (withstand pressure: 1.5 MPa) Measurement range *2 0 to 200 L/min 0 to 500 L/min 2 to 200 L/min 5 to 500 L/min Measurement range for specified accuracy *2 Display resolution *2 1 L/min ±2.0% F.S. at 50 L/min or higher Accuracy *2 ±0.5% F.S. at less than 50 L/min Temperature characteristic ±3% F.S. Repeat accuracy ±1% F.S. Operating temperature Operation: −10 to 60°C, Storage: −20 to 70°C (with no condensation or icing) Operating humidity Operation: 25% to 90% RH, Storage: 0% to 90% RH (with no condensation or icing) Shock resistance (destruction) 150 m/s2 3 times each in six directions (up/down, left/right, forward/backward) Pressure loss 2 kPa max. Power supply voltage 12 to 24 VDC ±10% ripple (p-p): 10% max. Current consumption 120 mA max. Functions Momentary flow, total flow, display reversal, zero point adjustment, peak and bottom hold, key lock, eco mode, scaling (analog output), judgement hysteresis, and teaching Indications 11-segment digital display (red); RUN, FUN, and THR (yellow); Out1 and Out2 (yellow); key lock (yellow); flow unit (green); and flow unit on reversed display (yellow) Outputs 4 kPa max. Analog Current output: 4 to 20 mA (1 output), Maximum load resistance: 300 Ω ON/OFF Open-collector output (2 outputs): 26.4 VDC 50 mA max. ON residual voltage: 2 V max. (Outputs can be selected from judgement output, pulse output, and Sensor error output.) RS-485 2-wire half-duplex communications with start-stop synchronization Baud rate: 9.6, 19.2, 38.4, or 115.2 kbps, Data bit length: 7 or 8 bits, Stop bit length: 1 or 2 bits, Parity: none, even, or odd, Terminating resistance (120 Ω): ON/OFF, Communications protocol: Conforms to CompoWay/F. Output interfaces Output values Momentary flow, total flow, judgement output *3, and Sensor error output Degree of protection IP65 Installation Direction and Straight Pipe Section A straight pipe section must be provided during installation and piping if the Sensor is installed horizontally and the display is on the top. *4 Connection pipe diameter Rc1/4 (8A) Materials Main unit: PBT, Flow channel: Zinc Dimensions 30 × 77 × 63.7 mm (W×D×H) Weight (in package) Approx. 400 g (500 g) Rc1/2 (15A) Accessories Instruction Sheet *1. Clean dry gas (Must not contain large particles, e.g. dust, oils, or mist.) *2. The flow rates are converted for the following conditions. Standard flow rate (std): 1 atmospheric pressure (101.3 kPa) at 20°C (default setting) Normal flow rate (nor): 1 atmospheric pressure (101.3 kPa) at 0°C *3. To prevent chattering, a judgement output is made when the judgement continues for one minute or longer. *4. The accuracy will depend on the length of the straight pipe section. Refer to Flow rate accuracy characteristics for a length of straight pipe on page 10 for details. 6 D6FZ Item Model Applicable fluid Working pressure Flow*1 0.99MPa max. Detection range 1 to 1,000 L/min (std) Resolution 0.1 L/min Accuracy Measurements Pressure Temperature Resistance to environment D6FZ-FGS1000 Air or nitrogen (N2) ±2.0% of reading at 50 L/min (std) or higher*2 ±0.1% F.S. at less than 50 L/min *2 Detection range 0 to 0.99 MPa Accuracy 2% F.S. Detection range −10 to 60°C Accuracy ±1.5% (absolute temperature) Operating temperature −10 to 60°C (with no condensation or icing) Operating humidity 35% to 85% RH (with no condensation or icing) Vibration resistance (destruction) 10 to 55 Hz with a 0.7-mm double amplitude or acceleration of 50 m/s2 for 80 min each in X, Y, and Z directions Shock resistance (destruction) 150 m/s2 3 times each in six directions (up/down, left/right, forward/backward) Pressure loss Direct piping: 10 kPa max. (0.5 MPa, at maximum flow) Using Coupler (TL model from Nagahori Industry Co., Ltd.): 10 kPa max. (0.5 MPa, at maximum flow) Power supply voltage For one Sensor: 16 to 24 VDC ±10%, ripple (p-p): 10% max., For multiple Sensors: 24 VDC ±10%, ripple (p-p): 10% max.*3 Power consumption 2 W max. Measurement cycle Approx. 62.5 ms Display Outputs Status display with 2-color LED (lit or flashing) Display method Displayed contents Output interfaces Output values Presence of power, air flow, and error alarm Analog Current output: 4 to 20 mA (2 outputs),*4 Maximum load resistance: 270 Ω ON/OFF Open-drain output (2 outputs),*5 24 VDC 50 mA max. ON residual voltage: 1.5 V max., OFF leakage current: 50 µA max. RS-485 2-wire half-duplex communications with start-stop synchronization Baud rate: 115.2 kbps (fixed), Data bit length: 8 bits (fixed), Stop bit length: 1 bit (fixed), Parity: even (fixed), Communications protocol: Conforms to CompoWay/F. Momentary standard flow, total standard flow, pressure, and Sensor error output Degree of protection IP64 (Except when switch cover is removed.) Wiring connection M12 connector (8-pin) Connection pipe diameter Rc1 (25A) (Bushing enables conversion to 15A or 20A.) Materials Cable: PVC (polyvinylchloride); Main unit: Aluminum die-cast; Display: Acrylic Dimensions 64 × 93 × 195 mm (W×D×H) (excluding flange) Weight (in package) Approx. 1.2 Kg (Approx. 1.7 Kg) Accessories Instruction Sheet *1. Flow rates are converted to 1 atmospheric pressure (101.3 kPa) at 20°C. *2. Does not include pressure and temperature accuracy. Conversion accuracy to the standard flow is ±2.5% of reading (at 20°C, 0.5 MPa). *3. Always ground the 0 V terminal, and do not ground the 24 V (+) terminal. There is a risk of malfunction. *4. The analog output is the momentary standard flow rate and pressure. *5. The total standard flow for the pulse output can be set to 1, 10 (default), 100, or 1,000 L (std) per pulse. 7 D6FZ Air Flow Station ItemModel D6FZ-FGX21 Connectable Sensors D6FZ-FGT200, D6FZ-FGT500, and D6FZ-FGS1000 Maximum number of connected Sensors 8*1 Indications 7-segment 5-digit 2-row LCD, auxiliary information indicators Recording interval 1 s, 2 s, 5 s, 10 s, 20 s, 30 s, or 1 min Displayed data Momentary flow rate, total flow rate, pressure, temperature, and billing amount/CO2 conversion Recorded data Momentary flow rate, total flow rate, volume flow rate, pressure, and temperature Calculation functions Conversion of total flow rate to billing amount/CO2 Recording modes Continue Mode*2 and Ring Mode*3 External output Alarm output (photocoupler output)*4 Communications interface Ethernet (10Base-T or 100Base-TX) Internal storage device Internal memory: Approx. 4,200 data items when 1 Sensor is connected, Approx. 650 data items when 8 Sensors are connected. External storage device SD card (to save measured values and to save/read set values), Recommended SD card: HMCSD291 (manufactured by OMRON)*5 Power supply voltage DC input: 24 VDC ±10%, ripple (p-p): 10% max. Current consumption 80 mA max. Operating temperature Without Ethernet: −10 to 40°C (with no condensation or icing), with Ethernet: 0 to 40°C (with no condensation or icing) Operating humidity 35% to 85% RH (with no condensation or icing) Storage humidity/temperature −15 to 60°C, 20% to 85% RH (with no condensation or icing) Insulation resistance 20 MΩ (at 500 VDC) Withstand voltage 1,000 VAC, 50/60 Hz for 1 min Vibration resistance (destruction) 10 to 150 Hz with a 0.7-mm double amplitude or acceleration of 50 m/s2 for 80 min each in X, Y, and Z directions Shock resistance (destruction) 150 m/s2 3 times each in six directions (up/down, left/right, forward/backward)*6 Material ABS Degree of protection IP30 Mounting method Magnet mounting, screw mounting, or hooks Dimensions 117.2 × 24.6 × 56.8 mm (W×D×H) (excluding protruding parts) Weight (in package) Approx. 150 g (Approx. 500 g) Instruction Sheet, Startup Guide, Utility Disk (CD-ROM),*7 Connection Cable,*8 Alarm Output Connector*9 *1. Up to 8 Sensors can be connected when the recording cycle is 2 seconds or longer; up to 4 Sensors can be connected when the recording cycle is 1 second. *2. Data is automatically written to the SD memory card when the internal memory reaches its capacity and recording continues until the SD memory card capacity is reached. Recording stops if there is no SD memory card inserted, when the internal memory capacity is reached, or when the SD memory card is write protected. (Recording can be resumed after inserting an SD memory card and outputting the data to it by pressing a button.) The default is Continue Mode. Use the enclosed software to change the recording mode. *3. Recording of the latest measured values continues until the internal memory reaches its capacity. (If the internal memory capacity is exceeded, data is overwritten from the oldest data in the memory.) *4. An alarm is output when the upper or lower limit of the air flow that was set in threshold setting mode is exceeded. *5. You can temporarily read and write data with an SD card that complies with SD/SDHC card standards and was made by another company, but the SD card may suddenly not be recognized, preventing you from accessing the data. *6. When mounting the Sensor with magnets, be sure to install it in a location where it will not be subjected to shock. *7. The Utility Disk contains the Multi Data Viewer Light, WZ Manager, and PDF manual. System Requirements for Enclosed Software: OS: Windows XP 32-bit edition, Windows Vista 32-bit edition, or Windows 7 32-bit edition, Processor: Intel-compatible processor of 1.5 GHz or higher.; Memory: 1 GB or more (Recommended: 2 GB or more) *8. A T-branch connector to connect to D6FZ-FC02. *9. OMRON's XW4B-02B1-H1 Connector. Accessories 8 D6FZ Connections Connection Diagrams With One Sensor A Cable with Connector on One End B Cable with Connectors on Both Ends Air Flow Station Connections PLC Connections A or A Terminal block A or 24-V power supply B Sensor setup Data display Data logging 24-V power supply Analog output Pulse output PLC Data Communications with Multiple Sensor Connections RS-485 Connections to Air Flow Station B RS-485 RS-485 Connections to PLC 24-V power supply A B Ethernet A RS-485 24-V power supply 8 max. B B B B Terminal block B B 8 max. Main pipe PLC B Main pipe Sensor settings Displayed data Data logging Wireless Data Collection Ethernet Wireless Unit Master (LAN) WZ-MLAN01 Wireless Unit Slave (Pulse Count) WZ-SP01 A A Main pipe Connects to up to 2 Sensors. The Triple Reliability of the 920 MHz Band Compared to the 2.4 GHz band: The reliability of a longer communications distance. The reliability of easier The reliability of less bending of waves bend interference from other around objects. communications devices. For detailed specifications, consult your OMRON sales representative. Refer to the user’s manuals for the Wireless Unit and Air Flow Sensors for detailed information on connections. 9 D6FZ Engineering Data Pressure Loss* (Typical) D6FZ-FGS1000 Minimum and Maximum Flow Rate Conversion Table (Typical) D6FZ-FGS1000 Pressure loss (kPa) 6 Temperature [°C] Atmospheric pressure 0.3 MPa 0.5 MPa 1.0 MPa 5 4 20 3 max. usable flow rate 2 25 1 0 30 0 200 400 600 800 1000 Flow rate (L/min (std)) D6FZ-FGT200 2 0.3 3.96 0.5 5.93 999.94 0.7 7.91 1000.00 0.3 3.89 656.17 0.5 5.83 983.17 0.7 7.78 1000.00 0.3 3.83 645.35 0.5 5.74 966.96 0.7 7.65 1000.00 667.37 The following graph shows the flow rate accuracy characteristics for a length of straight pipe (reference information). 0.5MPa D6FZ-FGT200 ±10% 0.75MPa Applied tube diameter*1 12 10 8 6 ±8% 1 0 Maximum flow rate [L/min (std)] atmospheric pressure 50 100 150 Precision F.S. [%] Pressure loss (kPa) Minimum flow rate [L/min (std)] Flow rate accuracy characteristics for a length of straight pipe D6FZ-FGT Only * Note: With direct piping. 0 Pressure [MPa] 200 ±6% ±4% ±2% Flow rate (L/min (std)) D6FZ-FGT500 ±0% 4 0 50 1 0 100 250 300 Applied steel pipe /tube diameter*1 20A 16 12 10 ±8% 2 Precision F.S. [%] Pressure loss (kPa) 200 ±10% 0.75MPa 0 150 D6FZ-FGT500 0.5MPa 3 100 Pipe length [mm] *2 atmospheric pressure 200 300 400 500 ±6% ±4% ±2% Flow rate (L/min (std)) ±0% 0 50 100 150 200 250 300 Pipe length [mm] *2 Straight Steel Pipe with Same Opening Diameter as Sensor Tube*1 Steel pipe with different diameter*1 Tube*1 Straight steel pipe length*2 Straight steel pipe length*2 Steel pipe with different diameter*1 10 D6FZ Safety Precautions Read the warranty and limitations of liability information. Air Flow Sensors Air Flow Station Warning This product cannot be used to detect people either directly or indirectly for the purpose of ensuring safety. Do not use the product as a detector for personal safety. The use of flammable gases may cause an explosion. Do not use the product in the presence of flammable gases. Electric shock may occur. Do not connect the product to an AC power supply. Warning The mounting magnets provided with the product have strong magnetism. If the product is mounted using these magnets, anyone wearing a heart pacemaker must not operate the product. Also, the product must not be brought into the proximity of such a person. This product contains lithium batteries. Serious injury may occur due to fire or explosion. Do not attempt to disassemble the product, deform it by applying pressure, heat it to a high temperature (100°C or higher), or incinerate it for disposal. Caution Do not use the product in an ambient atmosphere or environment that exceeds the ratings. Injury may occur due to an explosion. Flow rates and pressures must be within the specified working ranges. <D6FZ-FGT only> If water drops, oil, mist, or dust enters the product, it may result in measurement error or damage. Use clean gas. Dust and mist can affect the characteristics of Sensor or damage the Sensor. Install a filter and mist separator on the upstream tube. Also, install the product after removing any dust in the pipes with an air blow or other means. Precautions for Correct Use Wiring and Installation D6FZ-FGT Only Applicable Opening Diameter: D6FZ-FGT200: 8A, D6FZFGT500: 15A Always use a steel straight or elbow pipe with the same opening diameter. If a steel pipe with a different opening diameter or an air tube joint is required, you can reduce adverse influences by providing a section of straight pipe with the same opening diameter just before and after the Sensor. Refer to Flow rate accuracy characteristics for a length of straight pipe on page 10 for the required straight pipe length and measurement accuracy. 11 D6FZ (Unit: mm) Unspecified dimensional tolerances: Tolerance class IT16 Dimensions Air Flow Sensor D6FZ-FGT200 16±0.1 Four, 3.2 dia. ±0.1 holes 49.5±0.1 Mounting Hole Dimensions 47 33.7 12.65 Rc1/4, Effective depth: 10 mm 15 30 63.7 89.65 70 (60) 15 Rc1/4, Effective depth: 10 mm 30 77 49.5 ±0.1 7 16 ±0.1 Four, M3; Effective depth: 5 mm D6FZ-FGT500 16±0.1 Four, 3.2 dia. ±0.1 holes 49.5±0.1 Mounting Hole Dimensions 47 33.7 15 Rc1/2, Effective depth: 10 mm 12.65 30 63.7 89.65 70 (60) 15 Rc1/2, Effective depth: 10 mm 30 77 49.5 ±0.1 7 16 ±0.1 Four, M3; Effective depth: 5 mm D6FZ-FGS1000 14.9 dia. 43 Rc1 (both sides) DIP switch M12 200±50 Ferrite core 195 45.8 131.5 59.2 28 Rotary switch Switch cover Switch Cover Removed 64 88 93 Status indicator 12 D6FZ Air Flow Station D6FZ-FGX21 60 2 -M3 2-4 Screw catch-hole dimensions 40 Screw catch-holes dia. Mounting screw holes, Two M3 holes; Hole depth: 4 Mounting screw hole dimensions 117.2 Up Selection Key Down Selection Key 56.8 48.6 49.4 Mode Key 40 60 SET/REC/STOP Key T-branch connector plug Display 24.60.7 Reset switch T-branch Connection Cables 16.7 21 8.7 LAN port SD memory card slot Alarm output terminal Standard length: 1.5 m Cables with Connector on One End ole -h D6FZ-JD3A (L = 3 m) D6FZ-JD10A (L = 10 m) D6FZ-JD20A (L = 20 m) ro . th dia 2) ing depth: 8-dia. M12 socket 14.9 dia. ho h- M12 socket di a. th ro ug Plate D6FZ-JD3B (L = 3 m) D6FZ-JD5B (L = 5 m) D6FZ-JD10B (L = 10 m) D6FZ-JD20B (L = 20 m) 18 Back M12 plug 39.5 26.8 15-dia. 14.9 dia. M12 socket L Cables with Connectors on Both Ends 5- (Counte 13.6 CN1 14.9-dia. 26.8 le ole dep rsunk h 10 CN2 M12 plug CN0 39.5 th: 2) ntersink 8 dia. (cou 32.1 15 M12 socket 17.7 4.5 4. (56) 13.6 24.7 12 M12 socket L 43 26.8 14.9-dia. D6FZ-FC02 h ug 15-dia. T-branch Connector M12 socket Plate Mounting Bracket 60 40 .75 8.5 4-3 8-R1 5 ur, Fo s ole .h dia 3.2 5.25 49.5 25 16 48 40 16 4 4-3.5 D6FZ-FC03 1 13 Terms and Conditions Agreement Read and understand this catalog. Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranties. (a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron disclaims all other warranties, express or implied. (b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at Omron’s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other claims or expenses regarding the Products unless Omron’s analysis confirms that the Products were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above warranty. See http://www.omron.com/global/ or contact your Omron representative for published information. Limitation on Liability; Etc. OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY. Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted. Suitability of Use. Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases. NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Programmable Products. Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence thereof. Performance Data. Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability. Change in Specifications. Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change part numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at any time to confirm actual specifications of purchased Product. Errors and Omissions. Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors or omissions. 2016.4 In the interest of product improvement, specifications are subject to change without notice. OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2016 All Right Reserved.