Download

Air Flow Sensor
D6FZ
CSM_D6FZ_DS_E_2_3
Visualization of Compressed Air Flow
Rates, Pressures, and Leakage Rates on
Production Lines and Equipment
• Ideal for measuring compressed air in manufacturing lines and
equipment.
• Can be mounted behind curved pipes.
• The D6FZ-FGS1000 simultaneously measures the flow rate,
leakage rate, and pressure.
• The D6FZ-FGT200/500 provides easy-to-read 11-segment 8digit displays.
• Data can be easily logged at an air flow station.
• Many types of outputs (RS-485, analog, and pulse) to quickly
enable visualization on existing systems.
For the most recent information on models that have been certified for
safety standards, refer to your OMRON website.
Features
Visualize Air Flows, Pressures,
and Leakage to Save Energy
on Production Sites.
Consequently
Visualization is required on both the supply
side and consumption side. This leads to lower
power consumption while maintaining quality.
Power supply side
Consumption side
Monitor and control supply quantities
Maintain production quality
Optimize supply quantities
Optimize usage quantities
Compressed air on production line
Data logging
D6FZ-FGS1000
(1000L type)
Compressed air at machines
D6FZ-FGX21
D6FZ-FGT200/500
(200L/500L type)
Identify the waste that had previously been invisible to reduce the energy consumed for compressed air.
1
D6FZ
The Best Product to Measure
Compressed Air on Production Lines
D6FZ-FGS1000
1
2
3
Leakage
Usage
Pressure
Pipe size: Rc1 (25A)
(A bushing can be used to convert down to 15A.)
Multi-sensing
High Accuracy
Simultaneous Measurement of Flow,
Pressure, Leakage, and Temperature
The Sensor provides multiple sensing functions.
You can identify compressed air conditions with
just one Sensor.
Highly Accurate Flow Measurements
High measuring accuracy of ±2% R.S. (at 50 L/min or less) is achieved.
High accuracy
Flow Rate Measuring Accuracy
Pressure measurement
50
D6FZ-FGS (1000L/min max.)
40
Previous products (200L/min max.)
30
Flow
measurement
Previous products (1000L/min max.)
T
Temperature
measurement
Leakage
measurement
Accuracy R.S. [%]
20
10
0
-10
Measurement range
1,000 L/min max.
-20
Measuring accuracy
R.S. ±2.0%
(at 50 L/min or less)
-30
-40
-50
Simple Setup
0
50
100
150
200
00
950
1000
Flow rate [L/min]
Silencer
Mountable to
Curved Pipes or Couplers
The built-in silencer eliminates ultrasonic noise
and turbulence. It eliminates the need for straight
pipes to make installation work easy.
* Data is based on comparison for OMRON conditions
(November 2012).
Check the actual application environment before using
a Sensor.
Flow Measurements
over a Wide Range
Wide range
A wide measurement range of 1 to 1,000 L/min
is achieved.
Previous products
D6FZ-FGS
Straight
pipe not
required.
Resists Oils and Mist
Ultrasonic sensor
Easy installation
with a coupler.
A straight pipe with a
length that is 10 times
the opening diameter
is required.
Main
Features
Built-in suppressor to
suppress turbulence
and eliminate noise.
Two analog outputs
Two pulse outputs
RS-485 communications
IP64
Operation indicator
A built-in ultrasonic sensor is used for flow measurements.
With high resistance to rusty pipes and oil flooded
compressors, you can install the Sensor almost anywhere.
Threshold values
(peak, bottom, and leak)
Alarm hold
Flow
Leakage
Pressure
Temperature
measurement measurement measurement measurement
Feature
Comparison Curved pipe
Station
Multi-sensor
mounting
Resistant to oils and mist
connection
connection
2
D6FZ
Ideal for Compressed Air Measurements
at Machines
1
2
3
Leakage
Usage
Pressure
D6FZ-FGT200/500
200L type
500L type
Pipe size: 8A (Rc1/4) Pipe size: 15A (Rc1/2)
Easy to Read
High Accuracy
Highly Accurate Flow Measurements
First in the industry! *
11-segment 8-digit
LCD
An OMRON MEMS chip is used to achieve the highest
accuracy in the industry* of ±2% F.S. (at 50 L/min or less).
The characters are easy to read, and the total flow rate
can be checked in a glance.
clr
Clear total flow rate
With Flow
ave
Temperature
sensor
Without Flow
Temperature
sensor
Flow
Averaging count setting
Display Reversal
Heater
element
You can reverse the display direction to
match the installation direction.
Always use one of the specified installation
directions.
Note: Omron survey (as of June 2013)
Leakage Measurement
A high measurement accuracy of ±0.5% F.S. is achieved
at a low flow rate of less than 50 L/min.
This allows you to identify the air flow that is discarded
as leakage when machines are not operating to save money.
Press and hold to reverse.
Leakage on non-working days
(Saturday and Sunday) was 36 m 3!
Note: According to OMRON investigation in June 2013.
Specifications are the same as the 1000L type.
Zero Reset
Other Features
You can use the zero reset to identify seasonal
or day/night variations in the flow rates.
Flow Straightener with Honeycomb Structure
A honeycomb structure effectively straightens
the flow to keep pressure loss low.
Honeycomb structure
Press and hold.
Threshold values (peak, bottom, and leak)
One analog output
Peak/Bottom hold
Two pulse outputs
Main
RS-485 communications Auto-tuning
Features
Key lock
IP65
Display
Flow
Leakage
Pressure
Temperature
measurement measurement measurement measurement
Feature
Comparison Curved pipe Resistant to oils
Station
Multi-sensor
mounting
g
and mist
connection
connection
3
D6FZ
Enclosed Software Easily Analyzes Logged Data
You can collect onsite data at an Air Flow Station data and use the Multi Data Viewer Light software to analyze
the data in your office to identify other locations for improvement on the production site.
Free Enclosed software
On the
Production
Site:
Multi Data Viewer Light
In the Office:
This software displays data for specific time periods, such as by the minute,
e,
Data monitoring and
storing by Air Flow
Station
hour, or day. The total flow rate is displayed as a bar graph and the
e
momentary flow rate and pressure are displayed with dotted lines, so you can
n
Data storing and
analyzing
on a computer
see the overall situation at a glance.
The Air Flow Station enables
easy data logging.
Display period is easy to change.
Total flow rate (bar graph)
Pressure (dotted line graph)
Yo u c a n u s e c o m p a r a t i v e d i s p l a y s w i t h
previously logged data.
For example, side-by-side comparison of flow
rates by the day for different months is possible.
Save the data to
an SD memory card.
Check boxes allow you to display only the required data.
Start data logging with a single
Multi Data Viewer Light is on the enclosed utility disk (CD-ROM).
press of a button.
You can save energy in a variety of applications.
Stop Ionizer Idling
D6FZ-FGT
By stopping the supply of compressed air with a solenoid valve when there
is no workpiece, compressed air usage is reduced. At the same time, the
Flow Sensor monitors the quantity of supplied compressed air to ensure
that it is within the specified range. Therefore, the Sensor helps maintain
and improve quality.
Leakage Management
for Machines
D6FZ-FGT
D6FZ-FGS
Flow Management for
Molding Machines
D6FZ-FGT
D6FZ-FGS
By giving priority to the monitoring of molding machines and
other machines that use large quantities of compressed air,
energy is efficiently saved.
D6FZ-FGS
Flow and Pressure
Management for Production Lines
When the leak increases
Upper limit
During operation
Lower limit
Upper limit
During operation When operation is stopped
Lower limit
leak
Leak output
When operation is stopped
leak
ON
OFF
Leak output
ON
OFF
Set the leak threshold value to identify when
repairs for leaks are required.
Monitor consumption and pressure fluctuations for each
production line to identify bottleneck lines or machines to
implement onsite improvements and save energy.
4
D6FZ
Specifications
Units
Appearance
Product name
Model
200L-type Air Flow Sensor
D6FZ-FGT200
500L-type Air Flow Sensor
D6FZ-FGT500
1000L-type Air Flow Sensor
(cable length: 0.2 m)
D6FZ-FGS1000
Air Flow Station
(cable length: 1.5 m, including T-branch
Connector cable)
D6FZ-FGX21
1000L-type Air Flow Sensor Set
• 1000L-type Air Flow Sensor
• Air Flow Station
• T-branch Connector
• Cable with Connector on One End (3 m)
D6FZ-FGS1000-S
Options (Sold Separately)
Appearance
Product name
Model
T-branch Connector
D6FZ-FC02
(D6FZ-FGT Air Flow Sensor only)
Mounting Bracket
• Mounting Bracket: 1
• Phillips screws (M3): 4
D6FZ-FC03
(D6FZ-FGX21 Air Flow Station only)
Mounting magnets *
• Mounting magnets: 2
• Phillips screws (M3): 2
ZN9-EM01-S
Cable length: 3 m
Cable with Connector
on One End
Cable with
Connectors on Both
Ends
Cable length: 10 m
D6FZ-JD3A
M12 connector
(8-pin)
D6FZ-JD10A
Cable length: 20 m
D6FZ-JD20A
Cable length: 3 m
D6FZ-JD3B
Cable length: 5 m
Cable length: 10 m
Cable length: 20 m
M12 connector
(8-pin)
D6FZ-JD5B
D6FZ-JD10B
D6FZ-JD20B
* When magnets are used, the maximum vibration resistance is 55 Hz.
5
D6FZ
Ratings
Air Flow Sensor
Item
Model
D6FZ-FGT200
D6FZ-FGT500
Air or nitrogen (N2)*1
Applicable fluid
Maximum working pressure
0.75 MPa (withstand pressure: 1.5 MPa)
Measurement range *2
0 to 200 L/min
0 to 500 L/min
2 to 200 L/min
5 to 500 L/min
Measurement range for specified accuracy
*2
Display resolution
*2
1 L/min
±2.0% F.S. at 50 L/min or higher
Accuracy *2
±0.5% F.S. at less than 50 L/min
Temperature characteristic
±3% F.S.
Repeat accuracy
±1% F.S.
Operating temperature
Operation: −10 to 60°C, Storage: −20 to 70°C (with no condensation or icing)
Operating humidity
Operation: 25% to 90% RH, Storage: 0% to 90% RH (with no condensation or icing)
Shock resistance (destruction)
150 m/s2 3 times each in six directions (up/down, left/right, forward/backward)
Pressure loss
2 kPa max.
Power supply voltage
12 to 24 VDC ±10% ripple (p-p): 10% max.
Current consumption
120 mA max.
Functions
Momentary flow, total flow, display reversal, zero point adjustment, peak and bottom hold, key
lock, eco mode, scaling (analog output), judgement hysteresis, and teaching
Indications
11-segment digital display (red); RUN, FUN, and THR (yellow); Out1 and Out2 (yellow); key lock
(yellow); flow unit (green); and flow unit on reversed display (yellow)
Outputs
4 kPa max.
Analog
Current output: 4 to 20 mA (1 output), Maximum load resistance: 300 Ω
ON/OFF
Open-collector output (2 outputs): 26.4 VDC 50 mA max.
ON residual voltage: 2 V max. (Outputs can be selected from judgement output, pulse output,
and Sensor error output.)
RS-485
2-wire half-duplex communications with start-stop synchronization
Baud rate: 9.6, 19.2, 38.4, or 115.2 kbps, Data bit length: 7 or 8 bits, Stop bit length: 1 or 2 bits,
Parity: none, even, or odd, Terminating resistance (120 Ω): ON/OFF, Communications protocol:
Conforms to CompoWay/F.
Output
interfaces
Output values
Momentary flow, total flow, judgement output *3, and Sensor error output
Degree of protection
IP65
Installation Direction and Straight Pipe
Section
A straight pipe section must be provided during installation and piping if the Sensor is installed
horizontally and the display is on the top. *4
Connection pipe diameter
Rc1/4 (8A)
Materials
Main unit: PBT, Flow channel: Zinc
Dimensions
30 × 77 × 63.7 mm (W×D×H)
Weight (in package)
Approx. 400 g (500 g)
Rc1/2 (15A)
Accessories
Instruction Sheet
*1. Clean dry gas (Must not contain large particles, e.g. dust, oils, or mist.)
*2. The flow rates are converted for the following conditions. Standard flow rate (std): 1 atmospheric pressure (101.3 kPa) at 20°C (default setting)
Normal flow rate (nor): 1 atmospheric pressure (101.3 kPa) at 0°C
*3. To prevent chattering, a judgement output is made when the judgement continues for one minute or longer.
*4. The accuracy will depend on the length of the straight pipe section. Refer to Flow rate accuracy characteristics for a length of straight pipe on page
10 for details.
6
D6FZ
Item
Model
Applicable fluid
Working pressure
Flow*1
0.99MPa max.
Detection
range
1 to 1,000 L/min (std)
Resolution
0.1 L/min
Accuracy
Measurements
Pressure
Temperature
Resistance
to
environment
D6FZ-FGS1000
Air or nitrogen (N2)
±2.0% of reading at 50 L/min (std) or higher*2
±0.1% F.S. at less than 50 L/min *2
Detection
range
0 to 0.99 MPa
Accuracy
2% F.S.
Detection
range
−10 to 60°C
Accuracy
±1.5% (absolute temperature)
Operating temperature
−10 to 60°C (with no condensation or icing)
Operating humidity
35% to 85% RH (with no condensation or icing)
Vibration resistance
(destruction)
10 to 55 Hz with a 0.7-mm double amplitude or acceleration of 50 m/s2 for 80 min each in X, Y,
and Z directions
Shock resistance (destruction)
150 m/s2 3 times each in six directions (up/down, left/right, forward/backward)
Pressure loss
Direct piping: 10 kPa max. (0.5 MPa, at maximum flow)
Using Coupler (TL model from Nagahori Industry Co., Ltd.): 10 kPa max. (0.5 MPa, at maximum
flow)
Power supply voltage
For one Sensor: 16 to 24 VDC ±10%, ripple (p-p): 10% max.,
For multiple Sensors: 24 VDC ±10%, ripple (p-p): 10% max.*3
Power consumption
2 W max.
Measurement cycle
Approx. 62.5 ms
Display
Outputs
Status display with 2-color LED (lit or flashing)
Display method
Displayed contents
Output
interfaces
Output values
Presence of power, air flow, and error alarm
Analog
Current output: 4 to 20 mA (2 outputs),*4 Maximum load resistance: 270 Ω
ON/OFF
Open-drain output (2 outputs),*5 24 VDC 50 mA max.
ON residual voltage: 1.5 V max., OFF leakage current: 50 µA max.
RS-485
2-wire half-duplex communications with start-stop synchronization
Baud rate: 115.2 kbps (fixed), Data bit length: 8 bits (fixed), Stop bit length: 1 bit (fixed), Parity:
even (fixed), Communications protocol: Conforms to CompoWay/F.
Momentary standard flow, total standard flow, pressure, and Sensor error output
Degree of protection
IP64 (Except when switch cover is removed.)
Wiring connection
M12 connector (8-pin)
Connection pipe diameter
Rc1 (25A) (Bushing enables conversion to 15A or 20A.)
Materials
Cable: PVC (polyvinylchloride); Main unit: Aluminum die-cast; Display: Acrylic
Dimensions
64 × 93 × 195 mm (W×D×H) (excluding flange)
Weight (in package)
Approx. 1.2 Kg (Approx. 1.7 Kg)
Accessories
Instruction Sheet
*1. Flow rates are converted to 1 atmospheric pressure (101.3 kPa) at 20°C.
*2. Does not include pressure and temperature accuracy. Conversion accuracy to the standard flow is ±2.5% of reading (at 20°C, 0.5 MPa).
*3. Always ground the 0 V terminal, and do not ground the 24 V (+) terminal. There is a risk of malfunction.
*4. The analog output is the momentary standard flow rate and pressure.
*5. The total standard flow for the pulse output can be set to 1, 10 (default), 100, or 1,000 L (std) per pulse.
7
D6FZ
Air Flow Station
ItemModel
D6FZ-FGX21
Connectable Sensors
D6FZ-FGT200, D6FZ-FGT500, and D6FZ-FGS1000
Maximum number of connected Sensors
8*1
Indications
7-segment 5-digit 2-row LCD, auxiliary information indicators
Recording interval
1 s, 2 s, 5 s, 10 s, 20 s, 30 s, or 1 min
Displayed data
Momentary flow rate, total flow rate, pressure, temperature, and billing amount/CO2 conversion
Recorded data
Momentary flow rate, total flow rate, volume flow rate, pressure, and temperature
Calculation functions
Conversion of total flow rate to billing amount/CO2
Recording modes
Continue Mode*2 and Ring Mode*3
External output
Alarm output (photocoupler output)*4
Communications interface
Ethernet (10Base-T or 100Base-TX)
Internal storage device
Internal memory: Approx. 4,200 data items when 1 Sensor is connected, Approx. 650 data items
when 8 Sensors are connected.
External storage device
SD card (to save measured values and to save/read set values), Recommended SD card: HMCSD291 (manufactured by OMRON)*5
Power supply voltage
DC input: 24 VDC ±10%, ripple (p-p): 10% max.
Current consumption
80 mA max.
Operating temperature
Without Ethernet: −10 to 40°C (with no condensation or icing), with Ethernet: 0 to 40°C (with no
condensation or icing)
Operating humidity
35% to 85% RH (with no condensation or icing)
Storage humidity/temperature
−15 to 60°C, 20% to 85% RH (with no condensation or icing)
Insulation resistance
20 MΩ (at 500 VDC)
Withstand voltage
1,000 VAC, 50/60 Hz for 1 min
Vibration resistance (destruction)
10 to 150 Hz with a 0.7-mm double amplitude or acceleration of 50 m/s2 for 80 min each in X, Y,
and Z directions
Shock resistance (destruction)
150 m/s2 3 times each in six directions (up/down, left/right, forward/backward)*6
Material
ABS
Degree of protection
IP30
Mounting method
Magnet mounting, screw mounting, or hooks
Dimensions
117.2 × 24.6 × 56.8 mm (W×D×H) (excluding protruding parts)
Weight (in package)
Approx. 150 g (Approx. 500 g)
Instruction Sheet, Startup Guide, Utility Disk (CD-ROM),*7 Connection Cable,*8 Alarm Output
Connector*9
*1. Up to 8 Sensors can be connected when the recording cycle is 2 seconds or longer; up to 4 Sensors can be connected when the recording
cycle is 1 second.
*2. Data is automatically written to the SD memory card when the internal memory reaches its capacity and recording continues until the SD
memory card capacity is reached. Recording stops if there is no SD memory card inserted, when the internal memory capacity is reached, or
when the SD memory card is write protected. (Recording can be resumed after inserting an SD memory card and outputting the data to it by
pressing a button.) The default is Continue Mode. Use the enclosed software to change the recording mode.
*3. Recording of the latest measured values continues until the internal memory reaches its capacity. (If the internal memory capacity is exceeded,
data is overwritten from the oldest data in the memory.)
*4. An alarm is output when the upper or lower limit of the air flow that was set in threshold setting mode is exceeded.
*5. You can temporarily read and write data with an SD card that complies with SD/SDHC card standards and was made by another company,
but the SD card may suddenly not be recognized, preventing you from accessing the data.
*6. When mounting the Sensor with magnets, be sure to install it in a location where it will not be subjected to shock.
*7. The Utility Disk contains the Multi Data Viewer Light, WZ Manager, and PDF manual. System Requirements for Enclosed Software: OS:
Windows XP 32-bit edition, Windows Vista 32-bit edition, or Windows 7 32-bit edition, Processor: Intel-compatible processor of 1.5 GHz or
higher.; Memory: 1 GB or more (Recommended: 2 GB or more)
*8. A T-branch connector to connect to D6FZ-FC02.
*9. OMRON's XW4B-02B1-H1 Connector.
Accessories
8
D6FZ
Connections
Connection Diagrams
With One Sensor
A Cable with Connector on One End
B Cable with Connectors on Both Ends
Air Flow Station Connections
PLC Connections
A
or
A
Terminal
block
A
or
24-V power supply
B
Sensor setup
Data display
Data logging
24-V power supply
Analog output
Pulse output
PLC
Data Communications with Multiple Sensor Connections
RS-485 Connections to Air Flow Station
B
RS-485
RS-485 Connections to PLC
24-V power
supply
A
B
Ethernet
A
RS-485
24-V power
supply
8 max.
B
B
B
B
Terminal block
B
B
8 max.
Main pipe
PLC
B
Main pipe
Sensor settings
Displayed data
Data logging
Wireless Data Collection
Ethernet
Wireless Unit Master (LAN)
WZ-MLAN01
Wireless Unit Slave (Pulse Count)
WZ-SP01
A
A
Main pipe
Connects to
up to 2 Sensors.
The Triple Reliability of the 920 MHz Band
Compared
to the 2.4
GHz band:
The reliability of a
longer communications
distance.
The reliability of easier The reliability of less
bending of waves bend interference from other
around objects.
communications devices.
For detailed specifications, consult your OMRON sales representative.
Refer to the user’s manuals for the Wireless Unit and Air Flow Sensors for
detailed information on connections.
9
D6FZ
Engineering Data
Pressure Loss* (Typical)
D6FZ-FGS1000
Minimum and Maximum Flow Rate Conversion Table
(Typical)
D6FZ-FGS1000
Pressure loss (kPa)
6
Temperature
[°C]
Atmospheric pressure
0.3 MPa
0.5 MPa
1.0 MPa
5
4
20
3
max. usable flow rate
2
25
1
0
30
0
200
400
600
800
1000
Flow rate (L/min (std))
D6FZ-FGT200
2
0.3
3.96
0.5
5.93
999.94
0.7
7.91
1000.00
0.3
3.89
656.17
0.5
5.83
983.17
0.7
7.78
1000.00
0.3
3.83
645.35
0.5
5.74
966.96
0.7
7.65
1000.00
667.37
The following graph shows the flow rate accuracy characteristics for
a length of straight pipe (reference information).
0.5MPa
D6FZ-FGT200
±10%
0.75MPa
Applied tube
diameter*1
12
10
8
6
±8%
1
0
Maximum flow
rate
[L/min (std)]
atmospheric pressure
50
100
150
Precision F.S. [%]
Pressure loss (kPa)
Minimum flow
rate
[L/min (std)]
Flow rate accuracy characteristics for a length of straight
pipe
D6FZ-FGT Only
* Note: With direct piping.
0
Pressure
[MPa]
200
±6%
±4%
±2%
Flow rate (L/min (std))
D6FZ-FGT500
±0%
4
0
50
1
0
100
250
300
Applied steel pipe
/tube diameter*1
20A
16
12
10
±8%
2
Precision F.S. [%]
Pressure loss (kPa)
200
±10%
0.75MPa
0
150
D6FZ-FGT500
0.5MPa
3
100
Pipe length [mm] *2
atmospheric pressure
200
300
400
500
±6%
±4%
±2%
Flow rate (L/min (std))
±0%
0
50
100
150
200
250
300
Pipe length [mm] *2
Straight Steel Pipe with Same Opening Diameter as Sensor
Tube*1
Steel pipe with
different
diameter*1
Tube*1
Straight steel
pipe length*2
Straight steel
pipe length*2
Steel pipe with
different diameter*1
10
D6FZ
Safety Precautions
Read the warranty and limitations of liability information.
Air Flow Sensors
Air Flow Station
Warning
This product cannot be used to detect people either
directly or indirectly for the purpose of ensuring
safety.
Do not use the product as a detector for personal
safety.
The use of flammable gases may cause an
explosion.
Do not use the product in the presence of flammable
gases.
Electric shock may occur. Do not connect the
product to an AC power supply.
Warning
The mounting magnets provided with the product
have strong magnetism. If the product is mounted
using these magnets, anyone wearing a heart
pacemaker must not operate the product. Also, the
product must not be brought into the proximity of such a
person.
This product contains lithium batteries. Serious
injury may occur due to fire or explosion. Do not
attempt to disassemble the product, deform it by
applying pressure, heat it to a high temperature
(100°C or higher), or incinerate it for disposal.
Caution
Do not use the product in an ambient atmosphere or
environment that exceeds the ratings.
Injury may occur due to an explosion.
Flow rates and pressures must be within the
specified working ranges.
<D6FZ-FGT only>
If water drops, oil, mist, or dust enters the product, it
may result in measurement error or damage. Use
clean gas. Dust and mist can affect the
characteristics of Sensor or damage the Sensor. Install a filter
and mist separator on the upstream tube. Also, install the
product after removing any dust in the pipes with an air blow or
other means.
Precautions for Correct Use
Wiring and Installation
D6FZ-FGT Only
Applicable Opening Diameter: D6FZ-FGT200: 8A, D6FZFGT500: 15A
Always use a steel straight or elbow pipe with the same opening
diameter. If a steel pipe with a different opening diameter or an
air tube joint is required, you can reduce adverse influences by
providing a section of straight pipe with the same opening
diameter just before and after the Sensor.
Refer to Flow rate accuracy characteristics for a length of
straight pipe on page 10 for the required straight pipe length
and measurement accuracy.
11
D6FZ
(Unit: mm)
Unspecified dimensional tolerances: Tolerance class IT16
Dimensions
Air Flow Sensor
D6FZ-FGT200
16±0.1
Four, 3.2 dia. ±0.1 holes
49.5±0.1
Mounting Hole Dimensions
47
33.7
12.65
Rc1/4,
Effective
depth: 10 mm
15
30
63.7
89.65
70
(60)
15
Rc1/4,
Effective
depth: 10 mm
30
77
49.5 ±0.1
7
16 ±0.1
Four, M3;
Effective
depth: 5 mm
D6FZ-FGT500
16±0.1
Four, 3.2 dia. ±0.1 holes
49.5±0.1
Mounting Hole Dimensions
47
33.7
15
Rc1/2,
Effective
depth: 10 mm
12.65
30
63.7
89.65
70
(60)
15
Rc1/2,
Effective
depth: 10 mm
30
77
49.5 ±0.1
7
16 ±0.1
Four, M3;
Effective
depth: 5 mm
D6FZ-FGS1000
14.9 dia.
43
Rc1 (both sides)
DIP switch
M12
200±50
Ferrite core
195
45.8
131.5
59.2
28
Rotary switch
Switch cover
Switch Cover
Removed
64
88
93
Status indicator
12
D6FZ
Air Flow Station
D6FZ-FGX21
60
2 -M3
2-4
Screw catch-hole dimensions
40
Screw catch-holes
dia.
Mounting screw holes, Two M3 holes; Hole depth: 4
Mounting screw hole
dimensions
117.2
Up Selection Key
Down Selection Key
56.8
48.6
49.4
Mode Key
40
60
SET/REC/STOP Key
T-branch
connector plug
Display
24.60.7
Reset switch
T-branch Connection Cables
16.7
21
8.7
LAN port
SD memory
card slot
Alarm output terminal
Standard length: 1.5 m
Cables with Connector on One End
ole
-h
D6FZ-JD3A (L = 3 m)
D6FZ-JD10A (L = 10 m)
D6FZ-JD20A (L = 20 m)
ro
. th
dia
2)
ing depth:
8-dia.
M12 socket
14.9 dia.
ho
h-
M12 socket
di
a.
th
ro
ug
Plate
D6FZ-JD3B (L = 3 m)
D6FZ-JD5B (L = 5 m)
D6FZ-JD10B (L = 10 m)
D6FZ-JD20B (L = 20 m)
18
Back
M12 plug
39.5
26.8
15-dia.
14.9 dia.
M12 socket
L
Cables with Connectors on Both Ends
5-
(Counte
13.6
CN1
14.9-dia.
26.8
le
ole dep
rsunk h
10
CN2 M12 plug
CN0
39.5
th: 2)
ntersink
8 dia. (cou
32.1
15
M12 socket
17.7
4.5
4.
(56)
13.6 24.7
12
M12 socket
L
43
26.8
14.9-dia.
D6FZ-FC02
h
ug
15-dia.
T-branch Connector
M12 socket
Plate
Mounting Bracket
60
40
.75
8.5 4-3 8-R1
5
ur,
Fo
s
ole
.h
dia
3.2 5.25
49.5
25
16
48
40
16
4
4-3.5
D6FZ-FC03
1
13
Terms and Conditions Agreement
Read and understand this catalog.
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you
have any questions or comments.
Warranties.
(a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship
for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron
disclaims all other warranties, express or implied.
(b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT
NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER
ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE
PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE.
Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the
Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at
Omron’s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or
replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount
equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty,
repair, indemnity or any other claims or expenses regarding the Products unless Omron’s analysis confirms that the Products
were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate
modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall
not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or
electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice,
recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above
warranty.
See http://www.omron.com/global/ or contact your Omron representative for published information.
Limitation on Liability; Etc.
OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,
LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS,
WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.
Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted.
Suitability of Use.
Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the
combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable
third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself
is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine,
system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product
with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE
QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,
AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE
OVERALL EQUIPMENT OR SYSTEM.
Programmable Products.
Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence
thereof.
Performance Data.
Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining
suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate
it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability.
Change in Specifications.
Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our
practice to change part numbers when published ratings or features are changed, or when significant construction changes are
made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers
may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at
any time to confirm actual specifications of purchased Product.
Errors and Omissions.
Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is
assumed for clerical, typographical or proofreading errors or omissions.
2016.4
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2016 All Right Reserved.