Connecting Cables for Connector-Terminal Block Conversion Units (Shielded) XW2Z CSM_XW2Z_DS_E_4_1 Connect Connector-Terminal Block Conversion Units (XW2@) to I/O Units for Programmable Controllers with one touch. Shielded Ordering Information For 32-point, Connector-type I/O Units for Programmable Controllers XW2Z-@@@A (For XW2D-20G6/XW2B-20G@/-40G5-T/-20G5-D/ XW2C-20G5-IN16/20G6-IO16/XW2E-20G5-IN16/ XW2F-20G7-IN16/-OUT16/XW2N-20G8-IN16) XW2Z-@@@AU (For XW2D-20C6) Cable length L (m) * Model 0.5 XW2Z-050AU 1.0 XW2Z-100AU Model 1.5 XW2Z-150AU XW2Z-050A 2.0 XW2Z-200AU XW2Z-100A 3.0 XW2Z-300AU 1.5 XW2Z-150A 5.0 XW2Z-500AU 2.0 XW2Z-200A 3.0 XW2Z-300A 5.0 XW2Z-500A Cable length L (m) * 0.5 1.0 10.0 XW2Z-010A 15.0 XW2Z-15MA 20.0 XW2Z-20MA *Cable length L (m) L 1 XW2Z For 32-point, Connector-type I/O Units (Group 2) for Programmable Controllers For 64-point, Connector-type I/O Units for Programmable Controllers XW2Z-@@@B (For XW2D-40G6/XW2B-40G@) Type Cable length L (m) * XW2Z-@@@BU (For XW2D-40C6) Cable length L (m) * Model 0.5 XW2Z-050B 0.5 XW2Z-050BU 1.0 XW2Z-100B 1.0 XW2Z-100BU 1.5 XW2Z-150B 1.5 XW2Z-150BU 2.0 XW2Z-200B 2.0 XW2Z-200BU 3.0 XW2Z-300B 3.0 XW2Z-300BU 5.0 XW2Z-500B 5.0 XW2Z-500BU 10.0 XW2Z-010B 15.0 XW2Z-15MB 20.0 XW2Z-20MB Normal wiring 0.5 Reverse wiring Model XW2Z-050B-R1 1.0 XW2Z-100B-R1 1.5 XW2Z-150B-R1 2.0 XW2Z-200B-R1 3.0 XW2Z-300B-R1 5.0 Type Normal wiring XW2Z-@@@B-A (For XW2F-40G7-IN32) Type Normal wiring XW2Z-500B-R1 Cable length L (m) * Model 1.0 XW2Z-100B-A 1.5 XW2Z-150B-A 2.0 XW2Z-200B-A 3.0 XW2Z-300B-A 5.0 XW2Z-500B-A *Cable length L (m) XW2Z-@@@B-B (For XW2F-40G7-OUT32) Type L Normal wiring Cable length L (m) * Model 1.0 XW2Z-100B-B 1.5 XW2Z-150B-B 2.0 XW2Z-200B-B 3.0 XW2Z-300B-B 5.0 XW2Z-500B-B For 32-point, Connector-type Input Units (Group 2) for Programmable Controllers For 64-point, Connector-type Input Units for Programmable Controllers XW2Z-@@@D Cable length L (m) * Model A B 1.0 0.75 XW2Z-100D 1.5 1.25 XW2Z-150D 2.0 1.75 XW2Z-200D 3.0 2.75 XW2Z-300D 5.0 4.75 XW2Z-500D 10.0 9.75 XW2Z-010D 15.0 14.75 XW2Z-15MD 20.0 19.75 XW2Z-20MD *Cable length L (m) B (250 mm) Yellow CN3 CN1 Black CN2 (500 mm) A 20-pole Cable with Discrete-wire Press-fit Terminals XW2Z-@@@F Cable length L (m) * Model 1.0 XW2Z-100F 1.5 XW2Z-150F 2.0 XW2Z-200F 3.0 XW2Z-300F 5.0 XW2Z-500F 10.0 XW2Z-010F 15.0 XW2Z-15MF 20.0 XW2Z-20MF *Cable length L (m) Forked terminals (M3.5) XG4M-2030-T Devices L 300 (mm) 2 XW2Z For 32-point, Connector-type Output Units (Group 2) for Programmable Controllers For 64-point, Connector-type Output Units for Programmable Controllers XW2Z-@@@L Cable length L (m) * Model A B 1.0 0.75 XW2Z-100L 1.5 1.25 XW2Z-150L 2.0 1.75 XW2Z-200L 3.0 2.75 XW2Z-300L 5.0 4.75 XW2Z-500L 10.0 9.75 XW2Z-010L 15.0 14.75 XW2Z-15ML 20.0 19.75 XW2Z-20ML *Cable length L (m) B (250 mm) Green CN3 CN1 White (500 mm) CN2 A For 96-point, Connector-type I/O Units for Programmable Controllers XW2Z-@@@H-1 (For CS1-series I/O Unit Connection) Special Connecting Cables * Cable length L (m) Model 0.5 XW2Z-050H-1 1.0 XW2Z-100H-1 1.5 XW2Z-150H-1 2.0 XW2Z-200H-1 3.0 XW2Z-300H-1 5.0 XW2Z-500H-1 7.0 XW2Z-700H-1 10.0 XW2Z-010H-1 1.0 XW2Z-100H-1G 1.5 XW2Z-150H-1G 2.0 XW2Z-200H-1G 3.0 XW2Z-300H-1G 5.0 XW2Z-500H-1G *Cable length L (m) L *Up to two cables required for each Programmable Controller I/O Unit. Note: CS1 signal names connected to the XW2B/D are different for the XW2Z-@@@H-@ and the XW2Z-@@@H-@G. Refer to the I/O Signal Tables on page 9. XW2Z-@@@H-2 (For CS1-series I/O Unit Connection) Special Connecting Cables * Cable length L (m) Model A B 1.0 0.75 XW2Z-100H-2 1.5 1.25 XW2Z-150H-2 2.0 1.75 XW2Z-200H-2 3.0 2.75 XW2Z-300H-2 5.0 4.75 XW2Z-500H-2 10.0 9.75 XW2Z-010H-2 1.0 0.75 XW2Z-100H-2G 1.5 1.25 XW2Z-150H-2G 2.0 1.75 XW2Z-200H-2G 3.0 2.75 XW2Z-300H-2G 5.0 4.75 XW2Z-500H-2G *Cable length L (m) B (250 mm) Yellow CN3 CN1 Black (500 mm) CN2 A Linear lengths (not including bends) *Up to two cables required for each Programmable Controller I/O Unit. Note: CS1 signal names connected to the XW2B/D are different for the XW2Z-@@@H-@ and the XW2Z-@@@H-@G. Refer to the I/O Signal Tables on page 9. 3 XW2Z XW2Z-@@@H-3 (For CS1-series I/O Unit Connection) *Cable length L (m) C Special Connecting Cables * Cable length L (m) A B (500 mm) (250 mm) Model B C 1.0 0.75 1.0 XW2Z-100H-3 1.5 1.25 1.5 XW2Z-150H-3 2.0 1.75 2.0 XW2Z-200H-3 3.0 2.75 3.0 XW2Z-300H-3 5.0 4.75 5.0 XW2Z-500H-3 10.0 9.75 10.0 XW2Z-010H-3 Gray CN1 CN4 CN3 Yellow CN2 Black (500 mm) A Linear lengths (not including bends) *Up to two cables required for each Programmable Controller I/O Unit. For 32-point, MIL Connector-type I/O Units for Programmable Controllers XW2Z-@@@K Cable length L (m) * Model 0.25 XW2Z-C25K 0.5 XW2Z-C50K 1.0 XW2Z-100K 1.5 XW2Z-150K 2.0 XW2Z-200K 3.0 XW2Z-300K 5.0 XW2Z-500K *Cable length L (m) L XW2Z-@@@N Cable length L (m) * Model A B 1.0 0.75 XW2Z-100N 1.5 1.25 XW2Z-150N 2.0 1.75 XW2Z-200N 3.0 2.75 XW2Z-300N 5.0 4.75 XW2Z-500N 10.0 9.75 XW2Z-010N 15.0 14.75 XW2Z-15MN 20.0 19.75 XW2Z-20MN *Cable length L (m) B (250 mm) Green CN3 CN1 CN2 Black (500 mm) A Linear lengths (not including bends) XW2Z-@@@X Cable length L (m) * Model 0.5 XW2Z-C50X 1.0 XW2Z-100X 2.0 XW2Z-200X 3.0 XW2Z-300X 5.0 XW2Z-500X 10.0 XW2Z-010X *Cable length L (m) L 4 XW2Z Ratings and Specifications Rated current 1A Rated voltage 125 VAC 24 VDC Contact resistance 20 mΩ max. (at 20 mV, 100 mA max.) *1 Insulation resistance 100 MΩ min. (at 500 VDC) Dielectric strength 500 VAC for 1 min (leakage current: 1 mA max.) *2 Ambient operating temperature −25 to 80°C *1. Contact resistance for the Connector. *2. Dielectric strength for the Connector. Materials and Finish Item Part name Materials and Finish Housing XG4M-2030 XG4M-4030 Contacts Connectors XG4T-2004/4004 Fiber-glass reinforced PBT resin (UL94V-0)/black Cover Mating end Phosphor bronze/nickel base, 0.15-μm gold plating Press-fit end Phosphor bronze/nickel base, 2.0-μm tin plating Strain Relief Fiber-glass reinforced PBT resin (UL94V-0)/black Housing FCN-367J024-AU/F * FCN-367J040-AU/F Contacts Polyester resin (UL94V-0)/black Mating end Copper alloy/gold plated Press-fit end Copper alloy/tin plated Connecting screw Steel/nickel plated Cable UL2464 Interface Cable AWG28/Shielded Crimp terminal Forked crimp terminal 1.25 Y AS 3.5 or the equivalent Note: These housings, contacts, and connecting screws are made by Fujitsu. 5 XW2Z Appearance and Wiring Diagrams For 32-point, Connector-type I/O Units for Programmable Controllers XW2Z-@@@A XW2Z-@@@AU (For XW2D-20G6/XW2B-20G@/-40G5-T/-20G5-D/ XW2C-20G5-IN16/20G6-IO16/XW2E-20G5-IN16/ XW2F-20G7-IN16/-OUT16/XW2N-20G8-IN16) (For XW2D-20C6) Wiring Diagram Wiring Diagram FCN367J024-AU/F (mating side) FCN367J024-AU/F (mating side) 1 2 XG4M-2030-T (mating side) Triangular mark 2 1 1 1 2 2 4 6 6 7 7 XG4M-2030-U (mating side) 1 6 6 7 7 3 14 13 9 9 9 18 17 18 17 10 10 10 10 20 19 11 11 20 19 11 11 NC 12 12 B 4 Triangular mark 12 11 14 13 9 1 2 3 12 11 2 12 12 A B NC A For 32-point, Connector-type I/O Units (Group 2) for Programmable Controllers For 64-point, Connector-type I/O Units for Programmable Controllers XW2Z-@@@B (For XW2D-40G6/XW2B-40G@) Wiring Diagram • Reverse wiring • Normal wiring FCN367J040-AU/F (mating side) 1 2 FCN367J040-AU/F (mating side) XG4M-4030-T (mating side) 1 2 1 4 3 Triangular mark 2 20 20 2 1 4 3 Triangular mark 19 19 10 10 11 11 20 19 20 19 11 11 10 10 22 21 22 21 19 19 2 2 1 1 A B 38 37 38 37 20 20 40 39 B XG4M-4030-T (mating side) 40 39 A XW2Z-@@@BU (For XW2D-40C6) Wiring Diagram FCN367J040-AU/F (mating side) 1 1 2 2 XG4M-4030-U (mating side) 2 1 4 3 Triangular mark 10 10 20 19 11 11 22 21 19 19 38 37 20 20 40 39 B A 6 XW2Z XW2Z-@@@B-A (For XW2F-40G7-IN32) XW2Z-@@@B-B (For XW2F-40G7-OUT32) Wiring Diagram FCN367J040-AU/F B20 B19 B18 B17 B16 B15 B14 B13 B12 B11 B10 B9 B8 B7 B6 B5 B4 B3 B2 B1 A20 A19 A18 A17 A16 A15 A14 A13 A12 A11 A10 A9 A8 A7 A6 A5 A4 A3 A2 A1 Wiring Diagram XG4M-4030-T 1 2 3 5 7 9 11 13 15 17 19 4 6 8 10 12 14 16 18 20 21 22 23 25 27 29 31 33 35 37 39 24 26 28 30 32 34 36 38 40 FCN367J040-AU/F B20 B19 B18 B17 B16 B15 B14 B13 B12 B11 B10 B9 B8 B7 B6 B5 B4 B3 B2 B1 A20 A19 A18 A17 A16 A15 A14 A13 A12 A11 A10 A9 A8 A7 A6 A5 A4 A3 A2 A1 XG4M-4030-T 1 3 5 7 9 11 13 15 17 19 2 4 6 8 10 12 14 16 18 20 21 23 25 27 29 31 33 35 37 39 22 24 26 28 30 32 34 36 38 40 For 32-point, Connector-type Input Units (Group 2) for Programmable Controllers For 64-point, Connector-type Input Units for Programmable Controllers XW2Z-@@@D Wiring Diagram 1 2 8 8 9 1 4 3 16 15 18 17 20 19 9 10 10 11 11 17 17 18 18 19 19 20 20 B 2 1 2 FCN367J040-AU/F CN1 B20 B19 Triangular mark B18 B17 B16 B15 B14 B13 B12 B11 XG4M-2030-T NC B10 CN3 B9 (mating side) B8 B7 Triangular 2 1 B6 mark B5 4 3 B4 B3 B2 16 15 B1 XG4M-2030-T CN2 (mating side) FCN367J040-AU/F CN1 (mating side) NC 18 17 20 19 A Note: G79-I@C-@ Connecting Cables for the G7TC have different wiring and cannot be used with the XW2C. NC A20 A19 A18 A17 A16 A15 A14 A13 A12 A11 A10 A9 A8 A7 A6 A5 A4 A3 A2 A1 XG4M-2030-T CN3 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 XG4M-2030-T CN2 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 7 XW2Z 20-pole Cable with Discrete-wire Press-fit Terminals XW2Z-@@@F Connector Pin No. Table Forked terminal 1 2 3 4 Wiring Diagram XG4M-2030-T (mating side) 19 20 17 18 5 Forked terminals (M3.5) 20 19 18 17 6 7 8 9 10 Triangular mark 3 4 1 2 4 3 2 1 11 12 13 14 15 16 17 18 19 20 No. of cores 1 2 3 4 5 6 7 8 9 10 Insulation color Dot marks Dot color Connector pin No. Blue @ Red Blue @ Black 2 Pink @ Red 3 1 Pink @ Black 4 Green @ Red 5 Green @ Black 6 Orange @ Red 7 Orange @ Black 8 Gray @ Red 9 Gray @ Black 10 Blue @@ Red 11 Blue @@ Black 12 Pink @@ Red 13 Pink @@ Black 14 Green @@ Red 15 Green @@ Black 16 Orange @@ Red 17 Orange @@ Black 18 Gray @@ Red 19 Gray @@ Black 20 For 32-point, Connector-type Output Units (Group 2) for Programmable Controllers For 64-point, Connector-type Output Units for Programmable Controllers XW2Z-@@@L Wiring Diagram FCN367J040-AU/F CN1 B20 B19 B18 B17 B16 B15 B14 B13 B12 B11 B10 B9 B8 B7 B6 B5 B4 B3 B2 B1 A20 A19 A18 A17 A16 A15 A14 A13 A12 A11 A10 A9 A8 A7 A6 A5 A4 A3 A2 A1 XG4M-2030 CN3 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 XG4M-2030 CN2 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 8 XW2Z For 96-point, Connector-type I/O Units for Programmable Controllers XW2Z-@@@H (For CS1-series I/O Unit Connection) XW2Z-@@@H-1 XW2Z-@@@H-2 XW2Z-@@@H-3 I/O Signal Tables (Example Using CN1 on CS1W-OD291) XW2Z-@@@H-@ Connecting Cables XW2@-20G@ XW2Z-@@@H-3 0 1 1 2 3 3 5 Word N (CN2) 4 5 6 7 COM NC 0 9 11 13 15 17 19 1 7 6 1 2 3 5 Word N+1 (CN3) 3 4 5 6 7 COM NC 0 7 1 6 9 11 13 15 17 19 2 4 8 10 12 14 16 18 20 2 4 8 9 10 11 12 13 14 15 +V NC 8 9 10 11 12 13 14 15 +V NC 0 1 1 5 7 6 9 11 13 15 17 19 2 4 8 10 12 14 16 18 20 8 9 10 11 12 13 14 15 +V NC XW2@-20G@ 2 3 Word N+2 (CN4) 3 4 5 6 7 COM NC 2 3 8 10 12 14 16 18 20 XW2@-40G@ XW2Z-@@@H-2 1 3 5 Word N (CN2) 4 5 6 7 COM NC 0 7 6 Word N+1 (CN2) 3 4 5 6 7 COM NC 0 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 1 1 2 4 8 9 10 11 12 13 14 15 +V NC 8 2 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 9 10 11 12 13 14 15 +V NC 1 Word N+2 (CN3) 3 4 5 6 7 COM NC 2 3 5 7 6 9 11 13 15 17 19 2 4 8 10 12 14 16 18 20 8 9 10 11 12 13 14 15 +V NC XW2B-60G@ XW2Z-@@@H-1 0 1 1 2 3 3 5 Word N (CN2) 4 5 6 7 COM 0 7 1 Word N+1 (CN2) 3 4 5 6 7 COM 0 2 1 Word N+2 (CN2) 3 4 5 6 7 COM NC NC NC 2 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 43 45 47 49 51 53 55 57 59 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 2 4 6 8 9 10 11 12 13 14 15 +V 8 9 10 11 12 13 14 15 +V 9 10 11 12 13 14 15 +V NC NC NC 8 XW2Z-@@@H-@G/G79-@@@C-@@@-@@@ Connecting Cables XW2@-20G@ G79-@@@C-@@@@@@ Word N (CN2) +V NC 15 14 13 12 11 10 1 3 2 5 4 7 6 9 Word N+1 (CN3) +V NC 15 14 13 12 11 10 8 9 11 13 15 17 19 1 8 10 12 14 16 18 20 NC COM 7 6 5 4 3 2 1 0 3 2 5 4 7 6 9 9 11 13 15 17 19 6 5 4 3 2 1 3 2 3 2 0 5 4 7 6 NC COM 7 9 8 9 11 13 15 17 19 8 10 12 14 16 18 20 6 5 4 3 2 1 0 XW2@-20G@ Word N (CN2) +V NC 15 14 13 12 11 10 1 1 8 10 12 14 16 18 20 NC COM 7 XW2@-40G@ XW2Z-@@@H-2G Word N+2 (CN4) +V NC 15 14 13 12 11 10 8 5 4 7 6 Word N+ 1 (CN2) 8 +V NC 15 14 13 12 11 10 9 9 Word N +2 (CN3) +V NC 15 14 13 12 11 10 8 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 1 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 NC COM 7 6 5 4 3 2 1 0 NC COM 7 6 5 4 3 2 1 0 3 2 5 4 7 6 NC COM 7 9 8 9 11 13 15 17 19 8 10 12 14 16 18 20 6 5 4 3 2 1 0 XW2B-60G@ XW2Z-@@@H-1G Word N (CN2) +V NC 15 14 13 12 11 10 1 3 2 5 4 7 6 NC COM 7 Word N+1 (CN2) 8 +V NC 15 14 13 12 11 10 9 9 8 Word N+2 (CN2) +V NC 15 14 13 12 11 10 9 8 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 43 45 47 49 51 53 55 57 59 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 6 5 4 3 2 1 0 NC COM 7 6 5 4 3 2 1 0 NC COM 7 6 5 4 3 2 1 0 Note: The XW2Z-@@@H-@G I/O signal arrangement is oriented the same as the Connector Cable for the G79 I/O Relay Terminal. 9 XW2Z For 32-point, MIL Connector-type I/O Units for Programmable Controllers XW2Z-@@@K XW2Z-@@@N Wiring Diagram Wiring Diagram XG4M-4030-T (mating side) XG4M-4030-T (mating side) XG4M-4030-T (mating side) Triangular mark 39 40 2 1 39 40 37 38 4 3 37 38 21 22 20 19 23 24 19 20 22 21 21 22 XG4M-2030-T CN2 (mating side) Triangular mark 2 1 4 3 18 17 20 19 Triangular mark 19 20 17 18 3 4 38 37 1 2 40 39 Triangular mark Note: Connector pins are connected 1-to-1 so that pin numbers correspond. 3 4 1 2 2 1 4 3 18 17 20 19 Triangular mark XG4M-2030-T CN3 (mating side) XW2Z-@@@X Wiring Diagram XG4M-2030-T (mating side) XG4M-2030-T (mating side) Triangular mark 19 20 2 1 17 18 4 3 3 4 18 17 1 2 20 19 Triangular mark Note: Connector pins are connected 1-to-1 so that pin numbers correspond. 10 Terms and Conditions Agreement Read and understand this catalog. Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranties. (a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron disclaims all other warranties, express or implied. (b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at Omron’s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other claims or expenses regarding the Products unless Omron’s analysis confirms that the Products were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above warranty. See http://www.omron.com/global/ or contact your Omron representative for published information. Limitation on Liability; Etc. OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY. Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted. Suitability of Use. Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases. NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Programmable Products. Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence thereof. Performance Data. Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability. Change in Specifications. Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change part numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at any time to confirm actual specifications of purchased Product. Errors and Omissions. Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors or omissions. 2014.2 In the interest of product improvement, specifications are subject to change without notice. OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2014 All Right Reserved.