Download

Connecting Cables for Connector-Terminal Block Conversion Units (Shielded)
XW2Z
CSM_XW2Z_DS_E_4_1
Connect Connector-Terminal
Block Conversion Units (XW2@) to
I/O Units for Programmable
Controllers with one touch.
Shielded
Ordering Information
For 32-point, Connector-type I/O Units for Programmable Controllers
XW2Z-@@@A
(For XW2D-20G6/XW2B-20G@/-40G5-T/-20G5-D/
XW2C-20G5-IN16/20G6-IO16/XW2E-20G5-IN16/
XW2F-20G7-IN16/-OUT16/XW2N-20G8-IN16)
XW2Z-@@@AU (For XW2D-20C6)
Cable length L (m) *
Model
0.5
XW2Z-050AU
1.0
XW2Z-100AU
Model
1.5
XW2Z-150AU
XW2Z-050A
2.0
XW2Z-200AU
XW2Z-100A
3.0
XW2Z-300AU
1.5
XW2Z-150A
5.0
XW2Z-500AU
2.0
XW2Z-200A
3.0
XW2Z-300A
5.0
XW2Z-500A
Cable length L (m) *
0.5
1.0
10.0
XW2Z-010A
15.0
XW2Z-15MA
20.0
XW2Z-20MA
*Cable length L (m)
L
1
XW2Z
For 32-point, Connector-type I/O Units (Group 2) for Programmable Controllers
For 64-point, Connector-type I/O Units for Programmable Controllers
XW2Z-@@@B (For XW2D-40G6/XW2B-40G@)
Type
Cable length L (m) *
XW2Z-@@@BU (For XW2D-40C6)
Cable length L (m) *
Model
0.5
XW2Z-050B
0.5
XW2Z-050BU
1.0
XW2Z-100B
1.0
XW2Z-100BU
1.5
XW2Z-150B
1.5
XW2Z-150BU
2.0
XW2Z-200B
2.0
XW2Z-200BU
3.0
XW2Z-300B
3.0
XW2Z-300BU
5.0
XW2Z-500B
5.0
XW2Z-500BU
10.0
XW2Z-010B
15.0
XW2Z-15MB
20.0
XW2Z-20MB
Normal
wiring
0.5
Reverse
wiring
Model
XW2Z-050B-R1
1.0
XW2Z-100B-R1
1.5
XW2Z-150B-R1
2.0
XW2Z-200B-R1
3.0
XW2Z-300B-R1
5.0
Type
Normal
wiring
XW2Z-@@@B-A (For XW2F-40G7-IN32)
Type
Normal
wiring
XW2Z-500B-R1
Cable length L (m) *
Model
1.0
XW2Z-100B-A
1.5
XW2Z-150B-A
2.0
XW2Z-200B-A
3.0
XW2Z-300B-A
5.0
XW2Z-500B-A
*Cable length L (m)
XW2Z-@@@B-B (For XW2F-40G7-OUT32)
Type
L
Normal
wiring
Cable length L (m) *
Model
1.0
XW2Z-100B-B
1.5
XW2Z-150B-B
2.0
XW2Z-200B-B
3.0
XW2Z-300B-B
5.0
XW2Z-500B-B
For 32-point, Connector-type Input Units (Group 2) for Programmable Controllers
For 64-point, Connector-type Input Units for Programmable Controllers
XW2Z-@@@D
Cable length L (m) *
Model
A
B
1.0
0.75
XW2Z-100D
1.5
1.25
XW2Z-150D
2.0
1.75
XW2Z-200D
3.0
2.75
XW2Z-300D
5.0
4.75
XW2Z-500D
10.0
9.75
XW2Z-010D
15.0
14.75
XW2Z-15MD
20.0
19.75
XW2Z-20MD
*Cable length L (m)
B
(250 mm)
Yellow
CN3
CN1
Black
CN2
(500 mm)
A
20-pole Cable with Discrete-wire Press-fit Terminals
XW2Z-@@@F
Cable length L (m) *
Model
1.0
XW2Z-100F
1.5
XW2Z-150F
2.0
XW2Z-200F
3.0
XW2Z-300F
5.0
XW2Z-500F
10.0
XW2Z-010F
15.0
XW2Z-15MF
20.0
XW2Z-20MF
*Cable length L (m)
Forked
terminals
(M3.5)
XG4M-2030-T
Devices
L
300 (mm)
2
XW2Z
For 32-point, Connector-type Output Units (Group 2) for Programmable Controllers
For 64-point, Connector-type Output Units for Programmable Controllers
XW2Z-@@@L
Cable length L (m) *
Model
A
B
1.0
0.75
XW2Z-100L
1.5
1.25
XW2Z-150L
2.0
1.75
XW2Z-200L
3.0
2.75
XW2Z-300L
5.0
4.75
XW2Z-500L
10.0
9.75
XW2Z-010L
15.0
14.75
XW2Z-15ML
20.0
19.75
XW2Z-20ML
*Cable length L (m)
B
(250 mm)
Green
CN3
CN1
White
(500 mm)
CN2
A
For 96-point, Connector-type I/O Units for Programmable Controllers
XW2Z-@@@H-1 (For CS1-series I/O Unit Connection)
Special Connecting Cables *
Cable length L (m)
Model
0.5
XW2Z-050H-1
1.0
XW2Z-100H-1
1.5
XW2Z-150H-1
2.0
XW2Z-200H-1
3.0
XW2Z-300H-1
5.0
XW2Z-500H-1
7.0
XW2Z-700H-1
10.0
XW2Z-010H-1
1.0
XW2Z-100H-1G
1.5
XW2Z-150H-1G
2.0
XW2Z-200H-1G
3.0
XW2Z-300H-1G
5.0
XW2Z-500H-1G
*Cable length L (m)
L
*Up to two cables required for each Programmable Controller I/O Unit.
Note: CS1 signal names connected to the XW2B/D are different for the XW2Z-@@@H-@ and the XW2Z-@@@H-@G.
Refer to the I/O Signal Tables on page 9.
XW2Z-@@@H-2 (For CS1-series I/O Unit Connection)
Special Connecting Cables *
Cable length L (m)
Model
A
B
1.0
0.75
XW2Z-100H-2
1.5
1.25
XW2Z-150H-2
2.0
1.75
XW2Z-200H-2
3.0
2.75
XW2Z-300H-2
5.0
4.75
XW2Z-500H-2
10.0
9.75
XW2Z-010H-2
1.0
0.75
XW2Z-100H-2G
1.5
1.25
XW2Z-150H-2G
2.0
1.75
XW2Z-200H-2G
3.0
2.75
XW2Z-300H-2G
5.0
4.75
XW2Z-500H-2G
*Cable length L (m)
B
(250 mm)
Yellow
CN3
CN1
Black
(500 mm)
CN2
A
Linear lengths (not including bends)
*Up to two cables required for each Programmable Controller I/O Unit.
Note: CS1 signal names connected to the XW2B/D are different for the XW2Z-@@@H-@ and the XW2Z-@@@H-@G.
Refer to the I/O Signal Tables on page 9.
3
XW2Z
XW2Z-@@@H-3 (For CS1-series I/O Unit Connection)
*Cable length L (m)
C
Special Connecting Cables *
Cable length L (m)
A
B
(500 mm)
(250 mm)
Model
B
C
1.0
0.75
1.0
XW2Z-100H-3
1.5
1.25
1.5
XW2Z-150H-3
2.0
1.75
2.0
XW2Z-200H-3
3.0
2.75
3.0
XW2Z-300H-3
5.0
4.75
5.0
XW2Z-500H-3
10.0
9.75
10.0
XW2Z-010H-3
Gray
CN1
CN4
CN3
Yellow
CN2
Black
(500 mm)
A
Linear lengths (not including bends)
*Up to two cables required for each Programmable Controller I/O Unit.
For 32-point, MIL Connector-type I/O Units for Programmable Controllers
XW2Z-@@@K
Cable length L (m) *
Model
0.25
XW2Z-C25K
0.5
XW2Z-C50K
1.0
XW2Z-100K
1.5
XW2Z-150K
2.0
XW2Z-200K
3.0
XW2Z-300K
5.0
XW2Z-500K
*Cable length L (m)
L
XW2Z-@@@N
Cable length L (m) *
Model
A
B
1.0
0.75
XW2Z-100N
1.5
1.25
XW2Z-150N
2.0
1.75
XW2Z-200N
3.0
2.75
XW2Z-300N
5.0
4.75
XW2Z-500N
10.0
9.75
XW2Z-010N
15.0
14.75
XW2Z-15MN
20.0
19.75
XW2Z-20MN
*Cable length L (m)
B
(250 mm)
Green
CN3
CN1
CN2
Black
(500 mm)
A
Linear lengths (not including bends)
XW2Z-@@@X
Cable length L (m) *
Model
0.5
XW2Z-C50X
1.0
XW2Z-100X
2.0
XW2Z-200X
3.0
XW2Z-300X
5.0
XW2Z-500X
10.0
XW2Z-010X
*Cable length L (m)
L
4
XW2Z
Ratings and Specifications
Rated current
1A
Rated voltage
125 VAC 24 VDC
Contact resistance
20 mΩ max. (at 20 mV, 100 mA max.) *1
Insulation resistance
100 MΩ min. (at 500 VDC)
Dielectric strength
500 VAC for 1 min (leakage current: 1 mA max.) *2
Ambient operating
temperature
−25 to 80°C
*1. Contact resistance for the Connector.
*2. Dielectric strength for the Connector.
Materials and Finish
Item
Part name
Materials and Finish
Housing
XG4M-2030
XG4M-4030
Contacts
Connectors
XG4T-2004/4004
Fiber-glass reinforced PBT resin (UL94V-0)/black
Cover
Mating end
Phosphor bronze/nickel base, 0.15-μm gold plating
Press-fit end
Phosphor bronze/nickel base, 2.0-μm tin plating
Strain Relief
Fiber-glass reinforced PBT resin (UL94V-0)/black
Housing
FCN-367J024-AU/F *
FCN-367J040-AU/F
Contacts
Polyester resin (UL94V-0)/black
Mating end
Copper alloy/gold plated
Press-fit end
Copper alloy/tin plated
Connecting screw
Steel/nickel plated
Cable
UL2464 Interface Cable
AWG28/Shielded
Crimp terminal
Forked crimp terminal
1.25 Y AS 3.5 or the equivalent
Note: These housings, contacts, and connecting screws are made by Fujitsu.
5
XW2Z
Appearance and Wiring Diagrams
For 32-point, Connector-type I/O Units for Programmable Controllers
XW2Z-@@@A
XW2Z-@@@AU
(For XW2D-20G6/XW2B-20G@/-40G5-T/-20G5-D/
XW2C-20G5-IN16/20G6-IO16/XW2E-20G5-IN16/
XW2F-20G7-IN16/-OUT16/XW2N-20G8-IN16)
(For XW2D-20C6)
Wiring Diagram
Wiring Diagram
FCN367J024-AU/F
(mating side)
FCN367J024-AU/F
(mating side)
1
2
XG4M-2030-T
(mating side) Triangular
mark
2 1
1
1
2
2
4
6
6
7
7
XG4M-2030-U
(mating side)
1
6
6
7
7
3
14 13
9
9
9
18 17
18 17
10 10
10 10
20 19
11 11
20 19
11 11
NC
12 12
B
4
Triangular
mark
12 11
14 13
9
1
2
3
12 11
2
12 12
A
B
NC
A
For 32-point, Connector-type I/O Units (Group 2) for Programmable Controllers
For 64-point, Connector-type I/O Units for Programmable Controllers
XW2Z-@@@B (For XW2D-40G6/XW2B-40G@)
Wiring Diagram
• Reverse wiring
• Normal wiring
FCN367J040-AU/F
(mating side)
1
2
FCN367J040-AU/F
(mating side)
XG4M-4030-T
(mating side)
1
2
1
4
3
Triangular
mark
2
20 20
2
1
4
3
Triangular
mark
19 19
10 10
11 11
20 19
20 19
11 11
10 10
22 21
22 21
19 19
2
2
1
1
A
B
38 37
38 37
20 20
40 39
B
XG4M-4030-T
(mating side)
40 39
A
XW2Z-@@@BU (For XW2D-40C6)
Wiring Diagram
FCN367J040-AU/F
(mating side)
1
1
2
2
XG4M-4030-U
(mating side)
2
1
4
3
Triangular
mark
10 10
20 19
11 11
22 21
19 19
38 37
20 20
40 39
B
A
6
XW2Z
XW2Z-@@@B-A (For XW2F-40G7-IN32)
XW2Z-@@@B-B (For XW2F-40G7-OUT32)
Wiring Diagram
FCN367J040-AU/F
B20
B19
B18
B17
B16
B15
B14
B13
B12
B11
B10
B9
B8
B7
B6
B5
B4
B3
B2
B1
A20
A19
A18
A17
A16
A15
A14
A13
A12
A11
A10
A9
A8
A7
A6
A5
A4
A3
A2
A1
Wiring Diagram
XG4M-4030-T
1
2
3
5
7
9
11
13
15
17
19
4
6
8
10
12
14
16
18
20
21
22
23
25
27
29
31
33
35
37
39
24
26
28
30
32
34
36
38
40
FCN367J040-AU/F
B20
B19
B18
B17
B16
B15
B14
B13
B12
B11
B10
B9
B8
B7
B6
B5
B4
B3
B2
B1
A20
A19
A18
A17
A16
A15
A14
A13
A12
A11
A10
A9
A8
A7
A6
A5
A4
A3
A2
A1
XG4M-4030-T
1
3
5
7
9
11
13
15
17
19
2
4
6
8
10
12
14
16
18
20
21
23
25
27
29
31
33
35
37
39
22
24
26
28
30
32
34
36
38
40
For 32-point, Connector-type Input Units (Group 2) for Programmable Controllers
For 64-point, Connector-type Input Units for Programmable Controllers
XW2Z-@@@D
Wiring Diagram
1
2
8
8
9
1
4
3
16
15
18
17
20
19
9
10
10
11
11
17
17
18
18
19
19
20
20
B
2
1
2
FCN367J040-AU/F
CN1
B20
B19
Triangular mark
B18
B17
B16
B15
B14
B13
B12
B11
XG4M-2030-T
NC
B10
CN3
B9
(mating side)
B8
B7
Triangular
2 1
B6
mark
B5
4
3
B4
B3
B2
16 15
B1
XG4M-2030-T
CN2
(mating side)
FCN367J040-AU/F
CN1
(mating side)
NC
18
17
20
19
A
Note: G79-I@C-@ Connecting Cables for the G7TC have different wiring and
cannot be used with the XW2C.
NC
A20
A19
A18
A17
A16
A15
A14
A13
A12
A11
A10
A9
A8
A7
A6
A5
A4
A3
A2
A1
XG4M-2030-T
CN3
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
XG4M-2030-T
CN2
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
7
XW2Z
20-pole Cable with Discrete-wire Press-fit Terminals
XW2Z-@@@F
Connector Pin No. Table
Forked
terminal
1
2
3
4
Wiring Diagram
XG4M-2030-T
(mating side)
19
20
17
18
5
Forked
terminals
(M3.5)
20
19
18
17
6
7
8
9
10
Triangular
mark
3
4
1
2
4
3
2
1
11
12
13
14
15
16
17
18
19
20
No. of
cores
1
2
3
4
5
6
7
8
9
10
Insulation
color
Dot
marks
Dot
color
Connector
pin No.
Blue
@
Red
Blue
@
Black
2
Pink
@
Red
3
1
Pink
@
Black
4
Green
@
Red
5
Green
@
Black
6
Orange
@
Red
7
Orange
@
Black
8
Gray
@
Red
9
Gray
@
Black
10
Blue
@@
Red
11
Blue
@@
Black
12
Pink
@@
Red
13
Pink
@@
Black
14
Green
@@
Red
15
Green
@@
Black
16
Orange
@@
Red
17
Orange
@@
Black
18
Gray
@@
Red
19
Gray
@@
Black
20
For 32-point, Connector-type Output Units (Group 2) for Programmable Controllers
For 64-point, Connector-type Output Units for Programmable Controllers
XW2Z-@@@L
Wiring Diagram
FCN367J040-AU/F
CN1
B20
B19
B18
B17
B16
B15
B14
B13
B12
B11
B10
B9
B8
B7
B6
B5
B4
B3
B2
B1
A20
A19
A18
A17
A16
A15
A14
A13
A12
A11
A10
A9
A8
A7
A6
A5
A4
A3
A2
A1
XG4M-2030
CN3
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
XG4M-2030
CN2
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
8
XW2Z
For 96-point, Connector-type I/O Units for Programmable Controllers
XW2Z-@@@H (For CS1-series I/O Unit Connection)
XW2Z-@@@H-1
XW2Z-@@@H-2
XW2Z-@@@H-3
I/O Signal Tables (Example Using CN1 on CS1W-OD291)
XW2Z-@@@H-@ Connecting Cables
XW2@-20G@
XW2Z-@@@H-3
0
1
1
2
3
3
5
Word N (CN2)
4 5 6 7 COM NC
0
9 11 13 15 17 19
1
7
6
1
2
3
5
Word N+1 (CN3)
3 4 5 6 7 COM NC
0
7
1
6
9 11 13 15 17 19
2
4
8 10 12 14 16 18 20
2
4
8
9 10 11 12 13 14 15 +V NC
8
9 10 11 12 13 14 15 +V NC
0
1
1
5
7
6
9 11 13 15 17 19
2
4
8 10 12 14 16 18 20
8
9 10 11 12 13 14 15 +V NC
XW2@-20G@
2
3
Word N+2 (CN4)
3 4 5 6 7 COM NC
2
3
8 10 12 14 16 18 20
XW2@-40G@
XW2Z-@@@H-2
1
3
5
Word N (CN2)
4 5 6 7 COM NC 0
7
6
Word N+1 (CN2)
3 4 5 6 7 COM NC
0
9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39
1
1
2
4
8
9 10 11 12 13 14 15 +V NC 8
2
8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40
9 10 11 12 13 14 15 +V NC
1
Word N+2 (CN3)
3 4 5 6 7 COM NC
2
3
5
7
6
9 11 13 15 17 19
2
4
8 10 12 14 16 18 20
8
9 10 11 12 13 14 15 +V NC
XW2B-60G@
XW2Z-@@@H-1
0
1
1
2
3
3
5
Word N (CN2)
4 5 6 7 COM 0
7
1
Word N+1 (CN2)
3 4 5 6 7 COM 0
2
1
Word N+2 (CN2)
3 4 5 6 7 COM NC NC NC
2
9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 43 45 47 49 51 53 55 57 59
8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60
2
4
6
8
9 10 11 12 13 14 15 +V
8
9 10 11 12 13 14 15 +V
9 10 11 12 13 14 15 +V NC NC NC
8
XW2Z-@@@H-@G/G79-@@@C-@@@-@@@ Connecting Cables
XW2@-20G@
G79-@@@C-@@@@@@
Word N (CN2)
+V NC 15 14 13 12 11 10
1
3
2
5
4
7
6
9
Word N+1 (CN3)
+V NC 15 14 13 12 11 10
8
9 11 13 15 17 19
1
8 10 12 14 16 18 20
NC COM 7
6
5
4
3
2
1
0
3
2
5
4
7
6
9
9 11 13 15 17 19
6
5
4
3
2
1
3
2
3
2
0
5
4
7
6
NC COM 7
9
8
9 11 13 15 17 19
8 10 12 14 16 18 20
6
5
4
3
2
1
0
XW2@-20G@
Word N (CN2)
+V NC 15 14 13 12 11 10
1
1
8 10 12 14 16 18 20
NC COM 7
XW2@-40G@
XW2Z-@@@H-2G
Word N+2 (CN4)
+V NC 15 14 13 12 11 10
8
5
4
7
6
Word N+ 1 (CN2)
8 +V NC 15 14 13 12 11 10
9
9
Word N +2 (CN3)
+V NC 15 14 13 12 11 10
8
9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39
1
8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40
NC COM 7
6
5
4
3
2
1
0 NC COM 7
6
5
4
3
2
1
0
3
2
5
4
7
6
NC COM 7
9
8
9 11 13 15 17 19
8 10 12 14 16 18 20
6
5
4
3
2
1
0
XW2B-60G@
XW2Z-@@@H-1G
Word N (CN2)
+V NC 15 14 13 12 11 10
1
3
2
5
4
7
6
NC COM 7
Word N+1 (CN2)
8 +V NC 15 14 13 12 11 10
9
9
8
Word N+2 (CN2)
+V NC 15 14 13 12 11 10
9
8
9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 43 45 47 49 51 53 55 57 59
8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60
6
5
4
3
2
1
0 NC COM 7
6
5
4
3
2
1
0 NC COM 7
6
5
4
3
2
1
0
Note: The XW2Z-@@@H-@G I/O signal arrangement is oriented the same as the Connector Cable for the G79 I/O Relay Terminal.
9
XW2Z
For 32-point, MIL Connector-type I/O Units for Programmable Controllers
XW2Z-@@@K
XW2Z-@@@N
Wiring Diagram
Wiring Diagram
XG4M-4030-T
(mating side)
XG4M-4030-T
(mating side)
XG4M-4030-T
(mating side)
Triangular mark
39 40
2
1
39 40
37 38
4
3
37 38
21 22
20 19
23 24
19 20
22 21
21 22
XG4M-2030-T
CN2
(mating side) Triangular mark
2
1
4
3
18 17
20 19
Triangular mark
19 20
17 18
3
4
38 37
1
2
40 39
Triangular mark
Note: Connector pins are connected 1-to-1 so
that pin numbers correspond.
3
4
1
2
2
1
4
3
18 17
20 19
Triangular mark
XG4M-2030-T
CN3
(mating side)
XW2Z-@@@X
Wiring Diagram
XG4M-2030-T
(mating side)
XG4M-2030-T
(mating side)
Triangular mark
19 20
2
1
17 18
4
3
3
4
18 17
1
2
20 19
Triangular mark
Note: Connector pins are connected 1-to-1 so
that pin numbers correspond.
10
Terms and Conditions Agreement
Read and understand this catalog.
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you
have any questions or comments.
Warranties.
(a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship
for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron
disclaims all other warranties, express or implied.
(b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT
NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER
ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE
PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE.
Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the
Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at
Omron’s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or
replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount
equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty,
repair, indemnity or any other claims or expenses regarding the Products unless Omron’s analysis confirms that the Products
were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate
modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall
not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or
electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice,
recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above
warranty.
See http://www.omron.com/global/ or contact your Omron representative for published information.
Limitation on Liability; Etc.
OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,
LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS,
WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.
Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted.
Suitability of Use.
Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the
combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable
third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself
is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine,
system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product
with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE
QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,
AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE
OVERALL EQUIPMENT OR SYSTEM.
Programmable Products.
Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence
thereof.
Performance Data.
Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining
suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate
it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability.
Change in Specifications.
Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our
practice to change part numbers when published ratings or features are changed, or when significant construction changes are
made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers
may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at
any time to confirm actual specifications of purchased Product.
Errors and Omissions.
Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is
assumed for clerical, typographical or proofreading errors or omissions.
2014.2
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/