SITRANS FC MASS 2100 Catalog Specifications Sheet

© Siemens AG 2016
Flow Measurement
SITRANS F C
Flow sensor MASS 2100 DI 1.5
■ Overview
■ Application
In many industries such as the food and beverage or pharamceutical industry, accurate recipe control means everything. The
MASS 2100 DI 1.5 has demonstrated superiour performance in
numerous applications and field trails relating to accuracy and
turn-down ratio. It is today the preferred meter for research and
development and mini-plant applications for liquid or gas measurement, where measuring small quantities is important.
The main applications for the MASS 2100 DI 1.5 sensor can be
found in:
3
MASS 2100 DI 1.5 is suitable for low flow measurement applications of a variety of liquids and gases.
The sensor offers superior performance in terms of flow accuracy, turn-down ratio and density accuracy. The ease of installation through a "plug & play" mechanical and electrical interface
ensures optimum performance and operation.
The sensor delivers true multi-parameter measurements i.e.:
Mass flow, volume flow, density, temperature and fraction.
■ Benefits
• High accuracy better than 0.1 % of mass flow rate
• Large dynamic turn-down ratio better than 500:1, from 30 kg/h
to below 100 g/h
• Densitometer performance available through a density accuracy better than 0.001 g/cm3 with a repeatability better than
0.0002 g/cm3.
• Single continuous tube design, with no internal welds, reductions or flow splitters offers optimal hygiene, safety and CIP
cleanability for food and beverage and pharmaceutical applications.
• Market’s biggest wall thickness, ensuring optimal life-time and
corrosion resistance and high-pressure durability
• Balanced pipe design with little mechanical energy-loss, ensures optimal performance and stability under non-ideal and
unstable process conditions (pressure, temperature, densitychanges etc.).
• 4-wire Pt1000 temperature measurement ensures optimum
accuracy on mass flow, density and fraction flow
• Multi-plug electrical connector and SENSORPROM enables
true "plug & play". Installation and commissioning in less than
10 minutes
• Intrinsically safe Ex ia design as standard
• Sensor pipe available in high-quality stainless steel AISI 316L/
1.4435 or Hastelloy C22/2.4602 offering optimum corrosion resistance
• Dual-drive pick-up and driver construction facilitate ultra lowweight pipe construction giving the markets’ smallest and
most stable zero point.
• Rugged and space-saving sensor design in stainless steel
matching all environments
• High-pressure program as standard
• The sensor calibration factor is also valid for gas measurement.
3/210
Siemens FI 01 · 2016
Chemical industry
Liquid and gas measurement
within Miniplant and R & D, dosing
of additives and catalysts
Cosmetic industry
Dosing of essence and fragrances
Pharmaceutical industry
High-speed dosing and coating of
pills, filling of ampuls/injectors
Food and beverage industry
Dosing of flavourings, colours and
additives, density measurement,
inline measurement of liquid or
gaseous CO2
Automotive industry
Fuel injection nozzle and pump
testing, filling of AC units, engine
consumption, paint robots, ABS
test-beds
■ Design
The MASS 2100 sensor consists of a single bent tube in a double
omega pipe configuration, welded directly to the process connectors at each end.
The sensor is available in 2 material configurations, AISI 316L/
1.4404 or Hastelloy C22/2.4602 with ¼” NPT or ¼” ISO process
connections.
The enclosure is made in stainless steel AISI 316L/1.4404 with
a grade of encapsulation of IP65/NEMA 4.
The sensor is available in either a standard version with a maximum liquid temperature of 125 °C (257 °F) or a high-temperature version, with raised electrical connector for 180 °C (356 °F).
The sensor can be installed in horizontal or vertical position. The
enclosed single quick release clamp fitting which, along with its
compact design and single multi-plug electrical connector, will
keep installation costs and time to a minimum as shown below.
© Siemens AG 2016
Flow Measurement
SITRANS F C
Flow sensor MASS 2100 DI 1.5
■ Function
The measuring principle is based on the Coriolis effect. See
“System information SITRANS F C Coriolis mass flowmeters”.
■ Integration
The sensor can be connected to all MASS 6000 transmitters for
remote installation only.
All sensors are delivered with a SENSORPROM containing all information about calibration data, identity and factory pre-programming of transmitter settings
Installation guidelines MASS 2100 DI 1.5 (1/16“)
Installation of MASS 2100 sensor
• The optimal installation is horizontal.
If vertical mounting is necessary, upward flow is recommended to facilitate the removal of air bubbles. To remove the
air from the sensor the flow speed in the sensor must be at
least 1 m/s.
If there are solid particles in the liquid, especially in connection with low flow, it is recommended that the sensor be
mounted horizontally with inlet flange uppermost so that particles are more easily flushed out. To ensure that the sensor
does not become partially empty, there must be sufficient
counter-pressure on the unit min. 0.2 bar (2.9 psi).
• Mount the sensor on a vibration-free wall or steel frame.
• Locate the sensor low in the system in order to avoid an underpressure in the sensor separating air/gas in the liquid.
• Ensure that the sensor is not emptied of liquid (during normal
operation) otherwise incorrect measurement will occur.
■ Technical specifications
Inside pipe diameter (sensor consists of one continuous pipe)
1.5 mm (0.06”)
Pipe wall thickness
0.25 mm (0.010”)
Mass flow measuring range
0 ... 30 kg/h (0 ... 66 lb/h)
Density
0 ... 2.9 g/cm3 (0 ... 0.10 lb/inch3)
Fraction e.g.
0 ... 100 °Brix
Temperature
Standard
-50 ... +125 °C (-58 ... +257 °F)
High-temperature version
-50 ... +180 °C (-58 ... +356 °F)
Liquid pressure measuring pipe1)
Stainless steel
230 bar (3336 psi) at 20 °C
(68 °F)
Hastelloy C22/2.4602
365 bar (5294 psi) at 20 °C
(68 °F)
Materials
Measuring pipe and connection
Stainless steel AISI 316L/1.4435
Hastelloy C22/2.4602
Enclosure and enclosure material2)
IP65 and stainless steel
AISI316L/1.4404
Connection thread
ISO 228/1
G¼” male
ANSI/ASME B1.20.1
¼” NPT male
Cable connection
Multiple plug connection to sensor 5 x 2 x 0.35 mm2 twisted and
screened in pairs, ext. Ø 12 mm
Ex-version
II 1G Eex ia IIC T3-T6,
DEMKO 03
ATEX 135252X
c-UL-us
Ex ia IIC T3-T6
EAC Ex TC RU C–
DE.MIO62.B.02013
0Ex ia IIC T3…T6 Gb
UL WYMG.E232147
Weight approx.
2.6 kg (5.73 lb)
Horizontal
1)
According to DIN 2413, DIN 17457
2)
Housing is not rated for pressure containment.
For accuracy specifications see “System information
SITRANS F C”.
Pressure drop
Liquid and gas application
Vertical
Viscosity [cSt]
Δp [bar]
100
1000 500
200
100
50
10
20
10
5
1
1.0
0.1
Liquid application (left), gas application (right)
0.01
0.1
1
10
70
Mass flow [kg/h]
MASS 2100 DI 1.5 (1/16“), pressure drop for density = 1000 kg/m3
Siemens FI 01 · 2016
3/211
3
© Siemens AG 2016
Flow Measurement
SITRANS F C
Flow sensor MASS 2100 DI 1.5
Selection and Ordering data
Article No. Ord. code
Selection and Ordering data
SITRANS F C Flow sensors
7 ME 4 1 0 0 -
Additional information
MASS 2100 DI 1.5 (1/16“) sensor
7 77 7 7 - 7 7 7 7 7 7 7
Please add “-Z“ to Article No. and specify Order
code(s) and plain text.
Click on the Article No. for the online configuration in the PIA Life Cycle Portal.
3
Order code
Pressure testing certificate PED: 2014/68/EU
C11
Diameter
Material certificate EN 10204-3.1
C12
Stainless steel AISI 316L/1.4435
DI 1.5, max. 125 °C (257 °F)
DI 1.5, max. 180 °C (356 °F)
Welding certificate NDT-Penetrant: ISO 3452
C13
1A
1B
Factory certificate according to EN 10204 2.2
C14
Factory certificate according to EN 10204 2.1
C15
2A
2B
Tag name plate, stainless steel
Y17
Tag name plate, plastic
Y18
Customer-specific transmitter setup
Y20
Customer-specified, matched pair (5 x 2)
Y60
Customer-specified calibration (5 x 2)
Y61
Customer-specified, matched pair (10 x 1)
Y62
Customer-specified calibration (10 x 1)
Y63
Cleaned for oil and grease
Y80
Special version
Y99
Hastelloy C22/2.4602
DI 1.5, max. 125 °C (257 °F)
DI 1.5, max. 180 °C (356 °F)
Pressure
PN 100
PN 230 (AISI 316L/1.4404)
PN 365 (C22/2.4602)
D
L
P
Process connection/flange
Pipe thread
10
11
G ¼“ male
¼“ NPT male
Operating instructions for SITRANS F C MASS 2100 DI 1.5
Configuration
1
2
3
Standard
Density
Brix/Plato
Fraction (specification required)
9
N0Y
Transmitter
No transmitter, sensor and adapter only
A
MASS 6000, Ex d, stainless steel enclosure,
1 current, 1 freq./pulse and 1 relay output,
24 V AC/DC with Ex d e ib [ia Ga] IIC T4 Gb
Ex-approval.
B
MASS 6000, IP67, Polyamide enclosure,
cable glands M20, 1 current, 1 freq./pulse
and 1 relay output, 24 V AC/DC.
C
MASS 6000, IP67, Polyamide enclosure,
cable glands M20, 1 current, 1 freq./pulse
and 1 relay output, 115/230 V AC 50/60 Hz
D
MASS 6000, IP67, Polyamide enclosure,
cable glands ½" NPT, 1 current, 1 freq./pulse
and 1 relay output, 24 V AC/DC
E
MASS 6000, IP67, Polyamide enclosure, cable
glands ½" NPT, 1 current, 1 freq./pulse and 1
relay output, 115/230 V AC 50/60 Hz, ½" NPT
F
Cable
No cable
5 m (16.4 ft) cable
10 m (32.8 ft) cable
25 m (82 ft) cable
50 m (164 ft) cable
75 m (246 ft) cable
150 m (492 ft) cable
Description
Article No.
• English
A5E03089952
This device is shipped with a Quick Start guide and a CD containing
further SITRANS F literature.
All literature is available to download for free, in a range of languages, at
www.siemens.com/processinstrumentation/documentation
Accessories
Description
Article No.
Cable with multiple plug
Standard blue cable between
MASS 6000 and MASS 2100,
5 x 2 x 0.34 mm2 twisted and
screened in pairs. Temperature
range -20 °C ... +110 °C
(-4 °F ... +230 °F)
A
B
C
D
• 5 m (16.4 ft)
FDK:083H3015
• 10 m (32.8 ft)
FDK:083H3016
• 25 m (82 ft)
FDK:083H3017
• 50 m (164 ft)
FDK:083H3018
• 75 m (246 ft)
FDK:083H3054
• 150 m (492 ft)
FDK:083H3055
Spare parts
E
F
Description
Article No.
Multiple plug for cable
mounting
FDK:083H5056
2 kB SENSORPROM unit
FDK:083H4410
(Sensor Serial No. and Article No.
must be specified by ordering)
G
Calibration
Standard calibration 3 flow x 2 points
Standard calibration matched pair 3 flow x
2 points
Accredited calibration matched pair 5 flow x
2 points (DANAK)
1
2
Extended calibration customer-specified
select Y60, Y61, Y62 or Y63 (see additional
information)
8
3/212
Siemens FI 01 · 2016
3
Bracket
A5E02590427
© Siemens AG 2016
Flow Measurement
SITRANS F C
Flow sensor MASS 2100 DI 1.5
■ Dimensional drawings
MASS 2100 DI 1.5 (1/16“)
Ø57 (2.4)
15 (0.6)
12 (0.47)
64,5 (2.54)
NV21
G 1/4”
Ø18,8 (0.74)
Ø24 (0.94)
1/4” NPT
Ø18,8 (0.74)
Ø24 (0.94)
1/4” NPT
ANSI/ASME
B1.20.1-1983
10 (0.39)
4 (0.16)
120 (4.72)
20 (0.79)
15 (0.6)
12 (0.47)
86 (3.39)
152 (5.98)
NV21
3
78 (3.07)
20 (0.79)
Ø129 (5.08)
46 (1.81)
25 (0.98)
Ø 9 (0.35)
G 1/4”
ISO 228/1
100 (3.94)
Dimensions in mm (inch)
MASS 2100 DI 1.5 High-temperature version to 180 °C (356 °F)
Ø57 (2.4)
192,6 (7.58)
1/4” NPT
Ø18,8 (0.74)
Ø24 (0.94)
1/4” NPT
ANSI/ASME
B1.20.1-1983
4 (0.16)
120 (4.72)
NV21
G 1/4”
Ø18,8 (0.74)
Ø24 (0.94)
G 1/4”
ISO 228/1
Ø 9 (0.35)
20 (0.79)
NV21
15 (0.6)
12 (0.47)
15 (0.6)
12 (0.47)
86 (3.39)
152 (5.98)
10 (0.39)
64,5 (2.54)
78 (3.07)
20 (0.79)
Ø129 (5.08)
46 (1.81)
25 (0.98)
100 (3.94)
Dimensions in mm (inch)
Siemens FI 01 · 2016