FC300 DN4 Catalog Specification Sheet

© Siemens AG 2016
Flow Measurement
SITRANS F C
Flow sensor SITRANS FC300
• High-pressure program as standard
• The sensor calibration factor is also valid for gas measurement.
■ Overview
■ Application
The industry today has an increasing demand for mass flowmeters with a reduced physical size without loss of performance.
The meters must be suitable for installation in traditional process
industry environment as well as OEM equipment for instance
within automotive or appliance industry. Independent of industry
application the meter must deliver accurate and reliable measurements. The new and versatile design of the FC300 offers this
flexibility.
3
The main applications for the SITRANS FC300 DN 4 can be found in:
SITRANS FC300 is a compact Coriolis mass sensor suitable for
flow measurement of a variety of liquids and gases.
The sensor offers superior performance in terms of flow accuracy, turn-down ratio and density accuracy. The ease of installation through a „plug & play“ interface ensures optimum performance and operation.
A new designed encapsulation in stainless steel with a surprisingly low weight of only 3.5 kg (7.7 lb), ensures a rigid and robust
sensor performance for a wide range of applications.
■ Benefits
• High accuracy better than 0.1 % of mass flow rate
• Large dynamic turn-down ratio better than 500:1
• Densitometer performance available through a density accuracy as follows:
- For 316L/1.4404 version better than 0.007 g/cm3 (0.00025
lb/inch3) with repeatability better than 0.0002 g/cm3
(0.0000072 lb/inch3)
- For C22/2.4602 version better than 0.0025 g/cm3
(0.000090 lb/inch3) with repeatability better than
0.0002 g/cm3 (0.0000072 lb/inch3)
• One tube without internal welds, reductions or flow splitters offers optimal hygiene, safety and CIP cleanability for
food and beverage and pharmaceutical applications
• Larger wall thickness, ensures optimal life-time and corrosion
resistance and high-pressure durability
• Balanced pipe design with little mechanical energy loss, ensures optimal performance and stability under non-ideal and
unstable process conditions (pressure, temperature, densitychanges etc.).
• 4-wire Pt1000 temperature measurement ensures optimum
accuracy on mass flow, density and fraction flow
• Multi-plug electrical connector and SENSORPROM enable
true „plug & play“. Installation and commissioning in less than
10 minutes.
• Intrinsically safe Ex design ia IIC as standard
• Sensor pipe available in high-quality stainless steel
AISI 316L/1.4435 or Hastelloy C22/2.4602 offering optimum
corrosion resistance.
• Rugged and space-saving sensor design in stainless steel
matching all applications.
3/214
Siemens FI 01 · 2016
Chemical industry
Liquid and gas measurement in
normal as well as corrosive environments
Cosmetic industry
Dosing of essence and fragrances
Pharmaceutical industry
High-speed dosing and coating
of pills, filling of ampuls/injectors
Food and beverage industry
Filling, dosing of flavorings, colors
and additives, inline density measurement
Measurement and dosing of
liquid or gaseous CO2
Automotive industry
Fuel injection nozzle and pump
testing, filling of AC units, engine
consumption, paint robots, ABS
test-beds
■ Design
The FC300 sensor consists of a single tube bent in double
omega pipe geometry, welded directly to the process connectors at each end. The sensor is available in 2 material configurations, AISI 316L/1.4404 or Hastelloy C22/2.4602 with ¼”-NPT or
G¼”-ISO process connections.
The enclosure is made of stainless steel AISI 316L/1.4409 with a
grade of encapsulation of IP67/NEMA 4. The enclosure has a
very robust design and with an overall size of
130 x 200 x 60 mm (5.12“ x 7.87“ x 2.36“) the sensor is very compact and requires only little installation space.
The sensor can be delivered in a standard version with a maximum liquid temperature of 115 °C (239 °F) or a high-temperature version, with raised electrical connector for 180 °C (356 °F).
The sensor can be installed in horizontal or vertical position. The
sensor can be mounted directly on any given plane surface or if
desired with the enclosed quick release clamp fitting which,
along with its compact design and multi-plug electrical connector, will keep installation costs and time to a minimum.
■ Function
The measuring principle is based on the Coriolis effect. See
“System information SITRANS F C Coriolis mass flowmeters”.
■ Integration
The sensor can be connected to all MASS 6000 and
SIFLOW FC070 (standard and Ex types) transmitters for remote
installation only.
All sensors are delivered with a SENSORPROM containing all information about calibration data, identity and factory pre-programming of transmitter settings
© Siemens AG 2016
Flow Measurement
SITRANS F C
Flow sensor SITRANS FC300
Installation guidelines for SITRANS FC300 sensor
Horizontal installation as shown in figure A is recommended with
gas or liquid applications.
■ Technical specifications
Sensor size
DN 4 (1/6“)
This installation is also recommended when the flow velocity is
low (< 1 m/s) or the liquid contains solid particles or air bubbles.
Mass flow
Measuring range
0 ... 350 kg/h (0 ... 772 lb/h)
Vertical installation as shown in figure B can be used for liquid or
gas applications.
Accuracy, mass flow
0.1 % of rate
Repeatability
0.05 % of rate
For liquid applications upwards flow is recommended to facilitate the removal of air bubbles and to avoid partly emptying of
the sensor.
For gas applications we recommend to place the flow inlet on the
sensor high and the outlet low to remove impurities and oil films.
• To ensure that the sensor does not become partly empty, there
must be a sufficient counter-pressure on the unit min. 0.2 bar
(2.9 psi).
• Mount the sensor on a vibration-free and plane wall or steel
frame.
• Locate the sensor low in the system in order to avoid underpressure in the sensor separating air/gas in the liquid.
• Ensure that the sensor is not emptied of liquid (during normal
operation) otherwise incorrect measurement will occur.
Max. zero point error
0.010 kg/h (0.022 lb/h)
Horizontal mounting (recommended) (fig. A)
Density
Density range
3
0 ... 2.9 g/cm3
(0 ... 0.105 lb/inch3)
Density error
• Stainless steel
0.007 g/cm3
(0.00025 lb/inch3)
• Hastelloy C22/2.4602
0.0025 g/cm3
(0.00009 lb/inch3)
Repeatability error
0.0002 g/cm3
(0.0000072 lb/inch3)
Temperature
Standard
-40 ... +115 °C (-40 ... +239 °F)
High-temperature version
-40 ... +180 °C (-40 ... +356 °F)
Temperature error
0.5 °C (0.9 °F)
Brix
Measuring range
0 ... 100 °Brix
Brix error
0.3 °Brix
Inside pipe diameter
Stainless steel version
3.5 mm (0.14“)
Hastelloy version
3.0 mm (0.12“)
Pipe wall thickness
Stainless steel version
0.25 mm (0.0098“)
Liquid or gas (low to high flow)
Hastelloy version
0.5 mm (0.0196“)
Vertical mounting (fig. B)
Liquid pressure measuring pipe1)
Stainless steel
130 bar (1885 psi) at 20 °C
(68 °F)
Hastelloy C22/2.4602
410 bar (5945 psi) at 20 °C
(68 °F)
Materials
Stainless steel AISI 316L/1.4435
Measuring pipe and connection
Hastelloy C22/2.4602
Enclosure2)
Material
Stainless steel AISI 316L/1.4404
Enclosure grade
IP67/NEMA4
Connection thread
ISO 228/1
G¼” male
ANSI/ASME B1.20.1
¼” NPT male
Ex approval
Ex ia IIC T3-T6
05ATEX138072X
EAC Ex TC RU C–
DE.MIO62.B.02013
0Ex ia IIC T3…T6 Gb
Liquid or gas (medium to high flow)
c-UL-us Class 1 Div. 1,
Gr. A, B, C, D
Weight
3.5 kg (7.7 lb)
Dimensions
135 x 205 x 58 mm
(5.31“ x 8.07“ x 2.28“)
1)
According to DIN 2413, DIN 17457
2)
Housing is not rated for pressure containment.
Siemens FI 01 · 2016
3/215
© Siemens AG 2016
Flow Measurement
SITRANS F C
Flow sensor SITRANS FC300
Selection and Ordering data
Article No. Order code
Selection and Ordering data
SITRANS F C Flow sensors
7 ME 4 4 0 0 -
SITRANS FC300 DN 4 (1/6“) sensor
7 77 7 7 - 7 7 7 7 7 7 7
Additional information
Please add “-Z“ to Article No. and specify Order code(s)
and plain text.
Click on the Article No. for the online configuration in the PIA Life Cycle Portal.
Pipe material and temperature
Stainless steel AISI 316L/1.4435
115 °C (239 °F)
180 °C (356 °F)
3
Hastelloy C22/2.4602
115 °C (239 °F)
180 °C (356 °F)
Pressure
PN 100
PN 130 (316L/C22)
PN 410 (C22)
Pressure testing certificate PED: 2014/68/EU
C11
Material certificate EN 10204-3.1
C12
Welding certificate NDT-Penetrant: ISO 3452
C13
1G
1H
Factory certificate according to EN 10204 2.2
C14
Factory certificate according to EN 10204 2.1
C15
2G
2H
Tag name plate, stainless steel
Y17
Tag name plate, plastic
Y18
Customer-specific transmitter setup
Y20
Customer-specified, matched pair (5 x 2)
Y60
Customer-specified calibration (5 x 2)
Y61
Customer-specified, matched pair (10 x 1)
Y62
Customer-specified calibration (10 x 1)
Y63
Cleaned for oil and grease
Y80
Special version
Y99
D
G
Q
Process connection
Pipe thread
10
11
G ¼“ male
¼“ NPT male
Configuration
Standard
Density
Brix/Plato
Fraction (specification required)
Order code
Operating instructions for SITRANS F C FC300
1
2
3
9
N0Y
Transmitter
Description
Article No.
• English
A5E00698213
• German
A5E00728101
No transmitter, sensor and adapter only
A
This device is shipped with a Quick Start guide and a CD containing
further SITRANS F literature.
MASS 6000, Ex d, stainless steel enclosure,
1 current, 1 freq./pulse and 1 relay output,
24 V AC/DC with Ex d e ib [ia Ga] IIC T4 Gb
Ex-approval
B
All literature is available to download for free, in a range of languages, at
www.siemens.com/processinstrumentation/documentation
MASS 6000, IP67, Polyamide enclosure, cable
glands M20, 1 current, 1 freq./pulse and 1
relay output, 24 V AC/DC
C
MASS 6000, IP67, Polyamide enclosure, cable
glands M20, 1 current, 1 freq./pulse and 1
relay output, 115/230 V AC 50/60 Hz
D
MASS 6000, IP67, Polyamide enclosure, cable
glands ½" NPT, 1 current, 1 freq./pulse and 1
relay output, 24 V AC/DC
E
MASS 6000, IP67, Polyamide enclosure, cable
glands ½" NPT, 1 current, 1 freq./pulse and 1
relay output, 115/230 V AC 50/60 Hz, ½" NPT
F
Cable
No cable
5 m (16.4 ft) cable
10 m (32.8 ft) cable
25 m (82 ft) cable
50 m (164 ft) cable
75 m (246 ft) cable
150 m (492 ft) cable
Calibration
Standard calibration 3 flow x 2 points
Standard calibration matched pair 3 flow x
2 points
Accredited calibration matched pair 5 flow x 2
points (DANAK)
Extended calibration customer-specified
select Y60, Y61, Y62 or Y63 (see additional
information)
3/216
Siemens FI 01 · 2016
Accessories
Description
Article No.
Cable with multiple plug
Standard blue cable between
MASS 6000 and MASS 2100,
5 x 2 x 0.34 mm2 twisted and
screened in pairs. Temperature
range -20 °C ... +110 °C
(-4 °F ... +230 °F)
A
B
C
D
• 5 m (16.4 ft)
FDK:083H3015
• 10 m (32.8 ft)
FDK:083H3016
• 25 m (82 ft)
FDK:083H3017
• 50 m (164 ft)
FDK:083H3018
• 75 m (246 ft)
FDK:083H3054
• 150 m (492 ft)
FDK:083H3055
Spare parts
E
F
G
1
2
3
8
Description
Article No.
Multiple plug for cable
mounting
FDK:083H5056
2 kB SENSORPROM unit
FDK:083H4410
(Sensor Serial No. and Article No.
must be specified by ordering)
Mounting bracket in AISI 304
A5E02590439
© Siemens AG 2016
Flow Measurement
SITRANS F C
Flow sensor SITRANS FC300
■ Characteristic curves
Pressure drop
Viscosity [cSt]
Δp [bar]
1000
10
500
200
100
50
20
10
3
5
2
1
1.0
0.1
3
10
100
500
Mass flow [kg/h]
Stainless steel 316L/1.4404
9LVFRVLW\>F6W@
P [bar]
10
1.0
0.1
3
10
100
300 [kg/h]
Hastelloy C22/2.4602
Siemens FI 01 · 2016
3/217
© Siemens AG 2016
Flow Measurement
SITRANS F C
Flow sensor SITRANS FC300
■ Dimensional drawings
3
1/4”-18 NPT
Ø18,8 (0.74)
SITRANS FC300 DN 4
15 (0.59)
12 (0.47)
38 (1.50)
15 (0.59)
12 (0.47)
G 1/4”
Ø18,8 (0.740)
1/4”-18 NPT (ANSI/ASME B1.20.1)
G 1/4” (ISO 228/1 )
M8
NV 5 (0.20)
190 (3.54)
14 ± 2 (0.55 ± 0.08)
121 (4.76)
77 (3.03)
19 (0.75)
205 (8.07)
20 (1.33)
NV 24 (0.95)
M4
58 (2.28)
135 (5.31)
2 x M8
32 (1.26)
75 (2.95)
NV 6 (0.24)
SITRANS FC300, dimensions in mm (inch)
3/218
Siemens FI 01 · 2016
28,8 (1.134)
Ø27 (1.06)
18,8 (0.74)
110 (4.33)