SITRANS LVS200 Catalog Specifications Sheet

© Siemens AG 2016
Level Measurement
Point level measurement - Vibrating switches
SITRANS LVS200
■ Overview
■ Application
The standard LVS200 detects high, low, or demand levels of dry
bulk solids in bins, silos, or hoppers. The liquid/solid interface
version can also detect settled solids within liquids or solids
within confined spaces such as feed pipes. It is designed to
ignore liquids in order to detect the interface between a solid
and a liquid.
A pipe extension version is available with either the standard or
liquid/solid interface electronics and fork, separated by a customer supplied 1 inch pipe.
SITRANS LVS200 has an optional 4 to 20 mA output for monitoring buildup on the fork to determine when preventative maintenance should be performed in sticky applications.
The LVS200 has a compact design and can be top, side or angle
mounted. The vibrating fork design ensures the tines are kept
clean. The unique design of the fork and crystal assembly eliminates false high level readings even if tines become damaged.
SITRANS LVS200 is a vibrating point level switch for high, low, or
demand level detection of bulk solids.
■ Benefits
•
•
•
•
High resistance to mechanical forces
Strong vibration resistance to high bulk material loads
Rotatable enclosure for convenient wiring
Suitable for low density material: standard version, 20 g/l
(1.3 lb/ft3); liquid/solid interface version, 50 g/l (3 lb/ft3) and
low density option min. 5 g/l (0.3 lb/ft3)
• Customer desired extensions up to 20 000 mm (787 inch)
• Optional detection of solids within liquid
• Durable short fork option with 165 mm (6.5 inch) insertion
length
A signal from the electronic circuit excites a crystal in the probe
causing the fork to vibrate. If the fork is covered by material, the
change in vibration is detected by the electronic circuitry which
causes the relay to change state after a one second delay. When
the fork is free from material pressure, full vibration resumes and
the relay reverts to its normal condition.
• Key Applications: dry bulk solids in bins, silos, hoppers or
settled solids within liquids (interface version)
Siemens FI 01 · Update 05/2016
4/107
4
© Siemens AG 2016
Level Measurement
Point level measurement - Vibrating switches
SITRANS LVS200
■ Technical specifications
Medium conditions
Mode of operation
Measuring principle
Vibrating point level switch
• Process temperature
Input
Measured variable
High, low, and demand
Measuring frequency
• Standard
125 Hz
• Liquid/solid interface and short fork 350 Hz
version
PNP
Open collector:
Permanent load max. 0.4 A,
short-circuit and overload protected
Turn-on voltage: max. 50 V (reverse
protection)
2-wire without contact
Load current:
• Min. 10 mA
• Max. 500 mA permanent
• Max. 2A < 200 ms
• Max. 5A < 50 ms
Voltage drop on the electronic
module: max. 7 V with closed electric
circuit
Cut-off current with open electric
circuit: max. 5 mA
Relays
• Version with 1 relay
• Version with 2 relays
• Max. enclosure surface temperature 90 °C (194 °F)
(Category 2D)
• From loss of vibration:
approximately 1 second
• From resumption of vibration:
approximately 1 ... 2 seconds
Signal delay
• Probe uncovered to covered:
approximately 1 second
• Probe covered to
uncovered: approximately
1 ... 2 seconds
Relay fail-safe
High or low, switch selectable
Alarm output
• Relay 8 A at 250 V AC, non-inductive
• Relay 5 A at 30 V DC, non-inductive
mA output
• Resolution
8/16 mA or 4 ... 20 mA
4 ... 20 mA ± 0.1 mA
Sensitivity
High or low, switch selectable
Rated operating conditions
Installation conditions
• Location
• Pressure (vessel)
Max. 10 bar g (145 psi g) European
Pressure Directive 2014/68/EU:
Category 1
• Minimum material density
• Standard version: approx.
20 g/l (1.2 lb/ft3)
• Liquid/solid interface version:
approx. 50 g/l (3 lb/ft3)
• Optional low density version:
approx. 5 g/l (0.3 lb/ft3)
Design
Material
• Enclosure
Indoor/outdoor
Ambient conditions
• Ambient temperature
-40 ... +60 °C (-40 ... +140 °F)
• Installation category
III
• Pollution degree
2
Siemens FI 01 · Update 05/2016
Epoxy coated aluminum
Process connection
• Thread 1½" NPT [(Taper),
ANSI/ASME B1.20.1], R ½" [(BSPT),
EN 10226], and flange options
• Optional sliding bushing with 2" NPT
[(Taper), ANSI/ASME B1.20.1] or
BSP thread
• Thread material: stainless steel
303 (1.4301)
Tine material
Stainless steel 316L (1.4404),
PTFE-coated tines are available upon
special request
Degree of protection
IP65/Type 4/NEMA 4
Conduit entry
2 x M20 x 1.5 or 2 x ½" NPT
Weight
• Standard version, no extensions:
approx. 2.0 kg (4.4 lb)
• Solids/liquids version, no extensions: approx. 1.9 kg (4.2 lb)
Power supply
• 19 ... 230 V AC, +10 %,
50 ... 60 Hz, 8 VA
• 19 ... 55 V DC, +10 %, 1.5 W
SPDT relay
DPDT relay
Relay delay
4/108
• Max. threaded bushing temperature 60 °C (140 °F)
• Max. extension surface temperature 150 °C (302 °F)
(Category 1D)
Output
4
• All except CSA Class II, Group G:
-40 ... +150 °C (-40 ... +302 °F)
• CSA Class II, Group G:
-40 ... +140 °C (-40 ... +284 °F),
CSA temperature code T3B
Certificates and approvals
•
•
•
•
•
•
CSA/FM General Purpose
CE
CSA/FM Dust Ignition Proof
RCM
ATEX II 1/2 D
CSA/FM IS Class I, II, III Div. 1,
Groups A, B, C, D, E, F, G,
FM Class I, Aex ia IIC, CSA Class I,
Ex ia IIC, available only with power
supply options 5 and 6
• ATEX II 1G and 1/2 G Eex ia IIC;
ATEX II 1D and 1/2 D, available only
with power supply option 5
© Siemens AG 2016
Level Measurement
Point level measurement - Vibrating switches
SITRANS LVS200
Selection and Ordering data
Article No.
Selection and Ordering data
Article No.
SITRANS LVS200, standard
SITRANS LVS200 is a vibrating point level switch
for high, low, or demand level detection of bulk
solids.
7ML5731-
SITRANS LVS200, standard
SITRANS LVS200 is a vibrating point level switch
for high, low, or demand level detection of bulk
solids.
7ML5731-
7 7 7 7 7 - 77 A 0
Click on the Article No. for the online configuration in the PIA Life Cycle Portal.
Stainless steel 316L (1.4404)
Standard length, 235 mm (9.25 inch)
Power supply
19 ... 230 V AC, 19 ... 55 V DC, one relay output 
(SPDT)1)
19 ... 230 V AC, 19 ... 55 V DC, two relay outputs
(DPDT)1)
18 ... 50 V DC PNP1)

Add Order code Y01 and plain text:
"Insertion length ... mm"
1
2
3
4
19 ... 230 V AC/DC without contact, 2-wire loop
powered1)
7 ... 9 V DC (requires NAMUR switch amplifier)
NAMUR IEC 60947-5-6, 2-wire2)
8/16 mA or 4 ... 20 mA; 12.5 ... 35 V DC, 2-wire3)
5
6
19 ... 230 V AC, 19 ... 55 V DC, one relay output } 7
(SPDT) basic version4)5)
Process temperature
Without temperature isolator
}
With temperature isolator
Separated enclosure - cable length 1.5 m (4.92 ft)
[max. temperature process 150 °C (302 °F)/
max. temperature electronics 60 °C (140 °F)]
Separated enclosure - cable length 4.0 m (13.12 ft)
[max. temperature process150 °C (302 °F)/
max. temperature electronics 60 °C (140 °F)]
A
B
C
Process connection
Threaded
R 1½" [(BSPT), EN 10226]
1½" NPT [(Taper), ANSI/ASME B1.20.1]
G 2" [(BSPP), EN ISO 228-1], sliding sleeve
[min. length 500 mm (19.69 inch)]6)
}
}
D
2" ASME 150 lb B16.5
3" ASME 150 lb B16.5
4" ASME 150 lb B16.5
G
H
J
2" Tri-clamp (DN 50) ISO 2852
K
Extension length
Stainless steel 304 (1.4301)
Standard length, 235 mm (9.25 inch)
E
F
}
32
33
34
35
1 251 ... 1 500 mm (49.25 ... 59.06 inch)
1 501 ... 1 750 mm (59.09 ... 68.90 inch)
1 751 ... 2 000 mm (68.94 ... 78.74 inch)
36
37
38
2 001 ... 2 250 mm (78.78 ... 88.58 inch)
2 251 ... 2 500 mm (88.62 ... 98.43 inch)
2 501 ... 2 750 mm (98.46 ... 108.27 inch)
2 751 ... 3 000 mm (108.31 ... 118.11 inch)
41
42
43
44
3 001 ... 3 250 mm (118.15 ... 127.95 inch)
3 251 ... 3 500 mm (127.99 ... 137.80 inch)
3 501 ... 3 750 mm (137.83 ... 147.64 inch)
3 751 ... 4 000 mm (147.68 ... 157.48 inch)
45
46
47
48
}
Approvals
CSA/FM Dust Ignition Proof, RCM
}
ATEX II 1/2 D, RCM
}
CSA/FM General Purpose, RCM, CE

CE, RCM

CSA/FM IS Class I, II, III Div. 1, Groups A, B, C, D,
E, F, G, FM Class I, Aex ia IIC, CSA Class I,
Ex ia IIC, RCM
ATEX II 1G and 1/2G Eex ia IIC; ATEX II 1D and
1/2D, RCM
IEC-Ex t IIIC Da/Db
EAC Ex ta/tb IIIC Da/Db, Ex ta IIIC Da
EAC Ex Ga/Gb Ex ia IIC, 0Ex ia IIC Ga; Ex ta/tb
IIIC Da/Db, Ex ta IIIC Da
A
B
C
2" NPT [(Taper), ANSI/ASME B1.20.1],
sliding sleeve [min. length 500 mm (19.69 inch)]6)
Flanged
DN 100 PN 6, EN 1092-17)
DN 100 PN 16, EN 1092-1
31
300 ... 500 mm (11.81 ... 19.69 inch)
501 ... 750 mm (19.72 ... 29.53 inch)
751 ... 1 000 mm (29.57 ... 39.37 inch)
1 001 ... 1 250 mm (39.41 ... 49.21 inch)
Material process connection/extension
Stainless steel threads 304 (1.4301),
flanges 321 (1.4541), Tri-clamp 304 (1.4301)8)
Stainless steel 316L (1.4404)9)
D
7 7 7 7 7 - 77 A 0
1)
Available with Approval options A ... D, G only
2)
Available with Approval options D, E, F only
3)
Available with Approval options B, D, G only
4)
Available with configurations 7ML5731-7AA11-1BA0 or
7ML5731-7AB11-1AA0 only
5)
Basic version is cost effective and offers fast delivery
6)
Not available with extension length options 11, 12, 31, 32
7)
Max. 6 bar (87 psi)
8)
Available with option extension length 11 ... 28
9)
Available with option extension length 31 … 48
11
Add Order code Y01 and plain text:
"Insertion length ... mm"
• 300 ... 500 mm (11.81 ... 19.69 inch)
• 501 ... 750 mm (19.72 ... 29.53 inch)
• 751 ... 1 000 mm (29.57 ... 39.37 inch)



12
13
14
• 1 001 ... 1 250 mm (39.41 ... 49.21 inch)
• 1 251 ... 1 500 mm (49.25 ... 59.06 inch)
• 1 501 ... 1 750 mm (59.09 ... 68.90 inch)



15
16
17
• 1 751 ... 2 000 mm (68.94 ... 78.74 inch)
• 2 001 ... 2 250 mm (78.78 ... 88.58 inch)
• 2 251 ... 2 500 mm (88.62 ... 98.43 inch)



18
21
22
• 2 501 ... 2 750 mm (98.46 ... 108.27 inch)
• 2 751 ... 3 000 mm (108.31 ... 118.11 inch)
• 3 001 ... 3 250 mm (118.15 ... 127.95 inch)



23
24
25
• 3 251 ... 3 500 mm (127.99 ... 137.80 inch)
• 3 501 ... 3 750 mm (137.83 ... 147.64 inch)
• 3 751 ... 4 000 mm (147.68 ... 157.48 inch)



26
27
28
4
1
2
A
B
C
D
E
F
G
H
J
 We can offer shorter delivery times for configurations designated with the
Quick Ship Symbol . For details see page 9/5 in the appendix.
} Available ex stock. For details see page 9/5 in the appendix.
Siemens FI 01 · Update 05/2016
4/109
© Siemens AG 2016
Level Measurement
Point level measurement - Vibrating switches
SITRANS LVS200
Order code
Selection and Ordering data
Article No.
7ML5732-
Total insertion length: Enter the total insertion length
in plain text description, max. 4 000 mm
(157.48 inch)
Y01
SITRANS LVS200, short fork for liquids/
solids interface
Vibrating point level switch for solids or solids within liquid interface applications, and high load
applications with short insertion requirements
Stainless steel tag [100 x 45 mm (3.94 x 1.77 inch)]:
Measuring-point number/identification
(max. 27 characters); specify in plain text
Y14
Enhanced sensitivity > 5 g/l via electronics and
increased insertion length of 25 mm (0.98 inch)3)
K05
Enhanced sensitivity < 5 g/l via electronics,
increased insertion length of 25 mm (0.98 inch),
and increased aluminum fork width1)3)
G01
Signal bulb inserted in M20 cable gland2)
A20
Selection and Ordering data
Further Designs
Please add "-Z" to Article No. and specify Order
code(s).
4
NAMUR 8/16 mA switch amplifiers available,
contact factory for pricing
Operating Instructions
Article No.
Multi-language
7ML1998-5FT63
Note: the Operating Instructions should be ordered
as a separate line on the order.
All literature is available to download for free, in a
range of languages, at http://www.siemens.com/
processinstrumentation/documentation
This device is shipped with the Siemens Level and
Weighing manual DVD containing the ATEX Quick
Start and Operating Instructions library.
Spare Parts
Replacement Electronics Module (125 Hz)
[19 ... 230 V AC, 19 ... 55 V DC, one relay output
(SPDT)]
7ML1830-1KL
Replacement Electronics Module (125 Hz)
[19 ... 230 V AC, 19 ... 55 V DC, two relay output
(DPDT)]
A5E35525363
Sliding sleeve, 2" BSP (ISO 228)
7ML1830-1JM
Sliding sleeve, 2" NPT (ASME B1.20.1)
7ML1830-1JN
Namur Isolator switch amplifier relay output
KFD2-SR2-Ex1.W
A5E35667901
Available ex stock
For details see page 9/5 in the appendix.
SITRANS LVS200, standard, power supply 7,
process temperature A, process connection A,
extension length 11, material process connection/
extension 1, and approval B
7ML57317AA11-1BA0
SITRANS LVS200, standard, power supply 7,
process temperature A, process connection B,
extension length 11, material process connection/
extension 1, and approval A
7ML57317AB11-1AA0
1)
Available only with power supply 1 and Approval C, D and with
Process connection flange E ... J
2)
Available with Approval option D only
3)
K05 and G01 are not available together
4/110
Siemens FI 01 · Update 05/2016
77 7 77 - 77 A 0
Click on the Article No. for the online configuration in the PIA Life Cycle Portal.
Power supply
19 ... 230 V AC, 19 ... 55 V DC, one relay output
(SPDT)
19 ... 230 V AC, 19 ... 55 V DC, two relay outputs
(DPDT)
18 ... 50 V DC PNP
19 ... 230 V AC/DC without contact, 2-wire loop
powered
8/16 mA or 4 ... 20 mA; 12.5 ... 35 V DC, 2-wire1)
 1
2
3
4
5
Process temperature
Without temperature isolator

With temperature isolator
Separated enclosure - cable length 1.5 m (4.92 ft)
[max. temperature process 150 °C (302 °F)/
max. temperature electronics 60 °C (140 °F)]
Separated enclosure - cable length 4.0 m (13.12 ft)
[max. temperature process 150 °C (302 °F)/
max. temperature electronics 60 °C (140 °F)]
Process connection
Threaded
R 1½" [(BSPT), EN 10226]

1½" NPT [(Taper), ANSI/ASME B1.20.1]

G 2" [(BSPP), EN ISO 228-1], sliding sleeve
[min. length 500 mm (19.69 inch)]2)
2" NPT [(Taper), ANSI/ASME B1.20.1],
sliding sleeve [min. length 500 mm (19.69 inch)]2)
Flanged
DN 100 PN 6, EN 1092-13)
DN 100 PN 16, EN 1092-1
A
B
C
D
A
B
C
D
E
F
G
H
J
K
2" ASME 150 lb B16.5
3" ASME 150 lb B16.5
4" ASME 150 lb B16.5
2" Tri-clamp (DN 50) ISO 2852
Extension length
Stainless steel 304 (1.4301)
Standard length, 165 mm (6.50 inch)

11
Add Order code Y01 and plain text:
"Insertion length ... mm"
200 ... 500 mm (7.87 ... 19.69 inch)
501 ... 750 mm (19.72 ... 29.53 inch)
751 ... 1 000 mm (29.57 ... 39.37 inch)



12
13
14
1 001 ... 1 250 mm (39.41 ... 49.21 inch)
1 251 ... 1 500 mm (49.25 ... 59.06 inch)
1 501 ... 1 750 mm (59.09 ... 68.90 inch)



15
16
17
1 751 ... 2 000 mm (68.94 ... 78.74 inch)
2 001 ... 2 250 mm (78.78 ... 88.58 inch)
2 251 ... 2 500 mm (88.62 ... 98.43 inch)



18
21
22
2 501 ... 2 750 mm (98.46 ... 108.27 inch)
2 751 ... 3 000 mm (108.31 ... 118.11 inch)
3 001 ... 3 250 mm (118.15 ... 127.95 inch)



23
24
25
3 251 ... 3 500 mm (127.99 ... 137.80 inch)
3 501 ... 3 750 mm (137.83 ... 147.64 inch)
3 751 ... 4 000 mm (147.68 ... 157.48 inch)



26
27
28
© Siemens AG 2016
Level Measurement
Point level measurement - Vibrating switches
SITRANS LVS200
Selection and Ordering data
Article No.
Selection and Ordering data
SITRANS LVS200, short fork for liquids/
solids interface
Vibrating point level switch for solids or solids within liquid interface applications, and high load
applications with short insertion requirements
7ML5732-
Further Designs
77 7 77 - 77 A 0
Please add "-Z" to Article No. and specify Order
code(s).
Stainless steel 316L (1.4404)
Standard length, 165 mm (6.50 inch)
Add Order code Y01 and plain text:
"Insertion length ... mm"
200 ... 500 mm (7.87 ... 19.69 inch)
501 ... 750 mm (19.72 ... 29.53 inch)
751 ... 1 000 mm (29.57 ... 39.37 inch)
31
32
33
34
1 001 ... 1 250 mm (39.41 ... 49.21 inch)
1 251 ... 1 500 mm (49.25 ... 59.06 inch)
1 501 ... 1 750 mm (59.09 ... 68.90 inch)
1 751 ... 2 000 mm (68.94 ... 78.74 inch)
35
36
37
38
2 001 ... 2 250 mm (78.78 ... 88.58 inch)
2 251 ... 2 500 mm (88.62 ... 98.43 inch)
2 501 ... 2 750 mm (98.46 ... 108.27 inch)
41
42
43
2 751 ... 3 000 mm (108.31 ... 118.11 inch)
3 001 ... 3 250 mm (118.15 ... 127.95 inch)
3 251 ... 3 500 mm (127.99 ... 137.80 inch)
44
45
46
3 501 ... 3 750 mm (137.83 ... 147.64 inch)
3 751 ... 4 000 mm (147.68 ... 157.48 inch)
47
48
Material process connection/extension
Stainless steel threads 304 (1.4301),
flanges 321(1.4541), Tri-clamp 304 (1.4301)4)
Stainless steel 316L (1.4404)5)

1)
Available with Approval options B, D, E only
2)
Not available with extension length options 11,12, 31, 32
3)
Max. 6 bar (87psi)
4)
Available with option extension length 11 ... 28
5)
Available with option extension length 31 … 48
Total insertion length: Enter the total insertion length
in plain text description, max. 4 000 mm
(147.48 inch)
Y01
Stainless steel tag [100 x 45 mm (3.94 x 1.77 inch)]:
Measuring-point number/identification
(max. 27 characters); specify in plain text
Y14
Signal bulb inserted in M20 cable gland1)
A20
Adjustable sensitivity (by potentiometer) for solids/
liquids interface detection1)2)
G02
Operating Instructions
Article No.
Multi-language
7ML1998-5FT63
4
Note: the Operating Instructions should be ordered
as a separate line on the order.
All literature is available to download for free, in a
range of languages, at http://www.siemens.com/
processinstrumentation/documentation
This device is shipped with the Siemens Level and
Weighing manual DVD containing the ATEX Quick
Start and Operating Instructions library.
Spare Parts
1
2
Approvals
CSA/FM Dust Ignition Proof, RCM

ATEX II 1/2 D, RCM

CSA/FM General Purpose, RCM, CE

CE, RCM

IEC-Ex t IIIC Da/Db
ATEX II 1G and 1/2G Eex ia IIC; ATEX II 1D and
1/2D, CE, RCM
EAC Ex ta/tb IIIC Da/Db, Ex ta IIIC Da
EAC Ex Ga/Gb Ex ia IIC, 0Ex ia IIC Ga; Ex ta/tb IIIC
Da/Db, Ex ta IIIC Da
Order code
A
B
C
D
E
F
Replacement Electronics Module (125 Hz)
[19 ... 230 V AC, 19 ... 55 V DC, two relay output
(DPDT)]
A5E35525363
Replacement Electronics Module (350 Hz)
[19 ... 230 V AC, 19 ... 55 V DC, one relay output
(SPDT)]
7ML1830-1KM
Sliding sleeve, 2" BSP (ISO 228)
7ML1830-1JM
Sliding sleeve, 2" NPT (ASME B1.20.1)
7ML1830-1JN
1)
Available with Approval option D only
2)
Available with power supply option 1 only
G
H
 We can offer shorter delivery times for configurations designated with the
Quick Ship Symbol . For details see page 9/5 in the appendix.
Siemens FI 01 · Update 05/2016
4/111
© Siemens AG 2016
Level Measurement
Point level measurement - Vibrating switches
SITRANS LVS200
Selection and Ordering data
Article No.
Selection and Ordering data
SITRANS LVS200, pipe extension
Vibrating point level switch for high or low levels of
bulk solids
Extended using 1" pipe extension
(customer supplied)
7ML5733-
Further Designs
77 7 77 - 77 A 0
Please add "-Z" to Article No. and specify Order
code(s).
Total insertion length: Enter the total insertion length
in plain text description, max. 3 800 mm
(149.61 inch)
Y01
Stainless steel tag [100 x 45 mm (3.94 x 1.77 inch)]:
Measuring-point number/identification
(max. 27 characters); specify in plain text
Y14
2
Enhanced sensitivity > 5 g/l via electronics and
increased insertion length of 25 mm (0.98 inch)5)
K05
3
Enhanced sensitivity < 5 g/l via electronics,
increased insertion length of 25 mm (0.98 inch)
and increased aluminum fork width1)4)5)
G01
5
Adjustable sensitivity (by potentiometer) for solids/
liquids interface detection2)3)4)
G02
6
Signal bulb inserted in M20 cable gland2)
A20
Operating Instructions
Article No.
Multi-language
7ML1998-5FT63
Click on the Article No. for the online configuration in the PIA Life Cycle Portal.
Power supply
19 ... 230 V AC, 19 ... 55 V DC, one relay output
(SPDT)1)
19 ... 230 V AC, 19 ... 55 V DC, two relay outputs
(DPDT)1)
18 ... 50 V DC PNP1)
4
19 ... 230 V AC/DC without contact, 2-wire loop
powered1)
7 ... 9 V DC (requires NAMUR switch amplifier)
NAMUR IEC 60947-5-6, 2-wire2)
8/16 mA or 4 ... 20 mA; 12.5 ... 35 V DC, 2-wire3)
Process temperature
Up to 150 °C (302 °F)
1
4
A
Process connection
Threaded
R 1½" [(BSPT), EN 10226]
1½" NPT [(Taper), ANSI/ASME B1.20.1]
Note: the Operating Instructions should be ordered
as a separate line on the order.
All literature is available to download for free, in a
range of languages, at http://www.siemens.com/
processinstrumentation/documentation
This device is shipped with the Siemens Level and
Weighing manual DVD containing the ATEX Quick
Start and Operating Instructions library.
A
B
Flanged
DN 100 PN 6, EN 1092-14)
DN 100 PN 16, EN 1092-1
C
D
2" ASME 150 lb B16.5
3" ASME 150 lb B16.5
4" ASME 150 lb B16.5
2" Tri-clamp (DN 50) ISO 2852
E
F
G
K
Process connection material
Stainless steel threads 304 (1.4301),
flanges 321 (1.4541), Tri-clamp 304 (1.4301)
Stainless steel 316L (1.4404)
Extension length
Customer supplied 1" pipe extension
Length: 300 ... 3 800 mm (11.81 ... 149.61 inch)
Spare Parts
1
2
1
Application type
Dry bulk solids (125 Hz)
Liquids/solids interface (350 Hz)
Approvals
CSA/FM Dust Ignition Proof, RCM
ATEX II 1/2 D, RCM
CSA/FM General Purpose, RCM, CE
CE, RCM
CSA/FM IS Class I, II, III Div. 1, Groups A, B, C, D,
E, F, G, FM Class I, Aex ia IIC, CSA Class I,
Ex ia IIC, RCM
ATEX II 1G and 1/2G Eex ia IIC; ATEX II 1D and
1/2D, RCM
IEC-Ex t IIIC Da/Db
EAC Ex ta/tb IIIC Da/Db, Ex ta IIIC Da
EAC Ex Ga/Gb Ex ia IIC, 0Ex ia IIC Ga; Ex ta/tb IIIC
Da/Db, Ex ta IIIC Da
1)
Available with Approval options A, B, C, D, G only
2)
Available with approval options D, F, J and application type 1 only
3)
Available with Approval options B, D, G only
4)
Max. 6 bar (87 psi)
4/112
Siemens FI 01 · Update 05/2016
Order code
1
2
A
B
C
D
E
F
G
H
J
Replacement Electronics Module (125 Hz)
[19 ... 230 V AC, 19 ... 55 V DC, one relay output
(SPDT)]
7ML1830-1KL
Replacement Electronics Module (125 Hz)
[19 ... 230 V AC, 19 ... 55 V DC, two relay output
(DPDT)]
A5E35525363
Replacement Electronics Module (350 Hz)
[19 ... 230 V AC, 19 ... 55 V DC, one relay output
(SPDT)]
7ML1830-1KM
NAMUR Isolated switch amplifier Relay output
KFD2-SR2-Ex1.W
A5E35667901
1)
Available only with power supply 1 and Approvals C, D, and with
Process connection flange C … G
2)
Available with approval options D only
3)
Available with power supply option 1 only and application type 2
4)
Not available with option K05
5)
Available with Application type 1 only
© Siemens AG 2016
Level Measurement
Point level measurement - Vibrating switches
SITRANS LVS200
Selection and Ordering data
Article No.
Selection and Ordering data
Article No.
SITRANS LVS200, cable extended
Vibrating point level switch for high or low level
detection of bulk solids materials
7ML5734-
7ML5734-
7 7 7 7 7 - 77 A 0
SITRANS LVS200, cable extended
Vibrating point level switch for high or low level
detection of bulk solids materials
1
Approvals
CSA/FM Dust Ignition Proof, RCM
ATEX II 1/2 D, RCM
CSA/FM General Purpose, RCM, CE
Click on the Article No. for the online configuration in the PIA Life Cycle Portal.
Power supply
19 ... 230 V AC, 19 ... 55 V DC, one relay output
(SPDT)1)
19 ... 230 V AC, 19 ... 55 V DC, two relay outputs
(DPDT)1)
18 ... 50 V DC PNP1)
19 ... 230 V AC/DC without contact,
2-wire loop powered1)
7 ... 9 V DC (requires NAMUR switch amplifier)
NAMUR IEC 60947-5-6, 2-wire2)5)
8/16 mA or 4 ... 20 mA; 12.5 ... 35 V DC, 2-wire3)
Process temperature
Up to 80 °C (176 °F)
Process connection
Threaded
R 1½" [(BSPT), EN 10226] (1.4301/304)
1½" NPT [(Taper), ANSI/ASME B1.20.1]
(1.4301/304)
CE, RCM
CSA/FM IS Class I, II, III Div. 1, Groups A, B, C, D,
E, F, G, FM Class I, Aex ia IIC, CSA Class I,
Ex ia IIC, RCM
ATEX II 1G and 1/2G Eex ia IIC; ATEX II 1D and
1/2D, RCM6)
IEC-Ex t IIIC Da/Db
EAC Ex ta/tb IIIC Da/Db, Ex ta IIIC Da
EAC Ex Ga/Gb Ex ia IIC, 0Ex ia IIC Ga; Ex ta/tb IIIC
Da/Db, Ex ta IIIC Da
2
3
4
5
6
A
A
B
Flanged
DN 100 PN 6, EN 1092-1 (1.4541/321)4)
DN 100 PN 16, EN 1092-1 (1.4541/321)
C
D
2" ASME 150 lb B16.5 (1.4541/321)
3" ASME 150 lb B16.5 (1.4541/321)
4" ASME 150 lb B16.5 (1.4541/321)
E
F
G
Extension length
750 ... 1 000 mm (29.5 ... 39.4 inch) [max. length
20 000 mm (787.4 inch), not with Power supply
option 5 (max. 10 000 mm, 393.7 inch)]8)
1)
Available with Approval options A, B, C, D, G only
2)
Available with Approval options D, E, and F only.
Not available for application type 2 "Liquids/solids interface".
3)
Available with Approval option D only
4)
Max. 6 bar (87 psi)
5)
Not available with application type option 2
6)
Not available with Power supply option 5
7)
Cable length is limited to 7 000 mm (275.59 inch)
8) Available
A
B
C
D
E
F
G
H
J
with power supply options 1 … 4, and 6
10
Add Order code Y01 and plain text:
"Insertion length ... mm"
1 001 ... 2 000 mm (39.41 ... 78.74 inch)
2 001 ... 3 000 mm (78.78 ... 118.11 inch)
3 001 ... 4 000 mm (118.15 ... 157.48 inch)
11
12
13
4 001 ... 5 000 mm (157.52 ... 196.85 inch)
5 001 ... 6 000 mm (196.89 ... 236.22 inch)
6 001 ... 7 000 mm (236.26 ... 275.59 inch)
14
15
16
7 001 ... 8 000 mm (275.63 ... 314.96 inch)5)
8 001 ... 9 000 mm (315 ... 354.33 inch)5)
9 001 ... 10 000 mm (354.37 ... 393.70 inch)5)
17
18
20
10 001 ... 11000 mm (393.74 ... 433.07 inch)5)6)
11 001 ... 12 000 mm (433.11 ... 472.44 inch)5)6)
12 001 ... 13 000 mm (472.48 ... 511.81 inch)5)6)
21
22
23
13 001 ... 14 000 mm (511.85 ... 551.18 inch)5)6)
14 001 ... 15 000 mm (551.22 ... 590.55 inch)5)6)
15 001 ... 16 000 mm (590.59 ... 629.92 inch)5)6)
24
25
26
16 001 ... 17 000 mm (629.96 ... 669.29 inch)5)6)
17 001 ... 18 000 mm (669.33 ... 708.66 inch)5)6)
18 001 ... 19 000 mm (708.70 ... 748.03 inch)5)6)
19 001 ... 20 000 mm (748.07 ... 787.40 inch)5)6)
27
28
30
31
Application type
Dry bulk solids (125 Hz)
Liquid/solids interface (350 Hz)7)
7 7 7 7 7 - 77 A 0
1
2
Siemens FI 01 · Update 05/2016
4/113
4
© Siemens AG 2016
Level Measurement
Point level measurement - Vibrating switches
SITRANS LVS200
Selection and Ordering data
Order code
Further Designs
Please add "-Z" to Article No. and specify Order
code(s).
4
Enter the total insertion length in plain text
description, max. 20 000 mm (787.40 inch)
Y01
Stainless steel tag [100 x 45 mm (3.94 x 1.77 inch)]:
Measuring-point number/identification
(max. 27 characters); specify in plain text
Y14
Enhanced sensitivity > 5 g/l via electronics and
increased insertion length of 25 mm (0.98 inch)5)
K05
Enhanced sensitivity < 5 g/l via electronics and
increased insertion length of 25 mm (0.98 inch)
and increased aluminum fork width1)4)
G01
Adjustable sensitivity (by potentiometer) for solids/
liquids interface detection2)3)4)
G02
Signal bulb inserted in M20 cable gland2)
A20
Operating Instructions
Article No.
Multi-language
7ML1998-5FT63
Note: the Operating Instructions should be ordered
as a separate line on the order.
All literature is available to download for free, in a
range of languages, at http://www.siemens.com/
processinstrumentation/documentation
This device is shipped with the Siemens Level and
Weighing manual DVD containing the ATEX Quick
Start and Operating Instructions library.
Spare Parts
Replacement Electronics Module (125 Hz)
[19 ... 230 V AC, 19 ... 55 V DC,
one relay output (SPDT)]
7ML1830-1KL
Replacement Electronics Module (125 Hz)
[19 ... 230 V AC, 19 ... 55 V DC, two relay output
(DPDT)]
A5E35525363
Replacement Electronics Module (350 Hz)
[19 ... 230 V AC, 19 ... 55 V DC,
one relay output (SPDT)]
7ML1830-1KM
NAMUR Isolated switch amplifier Relay output
KFD2-SR2-Ex1.W
A5E35667901
1)
Available only with power supply 1 and Approvals C, D, and with
process connection flange C … G
2)
Available with Approval options D only
3)
Available with power supply option 1 and application type 2 only
4)
Not available with option K05
5)
Available with Application type 1 only
4/114
Siemens FI 01 · Update 05/2016
© Siemens AG 2016
Level Measurement
Point level measurement - Vibrating switches
SITRANS LVS200
150
(5.91)
Tine orientation
marking
Threaded bushing
[max. temp. 80 °C
(176 °F)]
Optional sliding
bushing*
Thread length
BSP: 20.5 (0.81)
NPT: 24 (0.94)
42 (1.67)
Tine
165 (6.5): Compact solids/ liquids interface model
230 (9.0): Compact standard version
300 ... 4 000
(11.81 ... 157): Customer-specified rigid extension
42 (1.67)
100 (3.94)
Solids/liquids
interface model
Tine
170 (6.69):
Standard model
100 (3.94)
Solids/liquids
interface model
170 (6.69):
Standard model
Customer supplied
process flange
195 (7.68)
60
(2.36)
700 ... 20 000 (27.56 ... 787)**
View A-A
A
75
(2.95)
120
(4.72)
60
(2.36)
A
155
(6.1)
■ Dimensional drawings
Notes:
* The clamping screws of the sliding bushing must be tightened to 10 Nm.
** Cable version with liquids/solids interface model option length to 7 000 mm (275.59 inch)
Cable version with NAMUR electronics length to 10 000 mm (393.7 inch) tightened to 10 Nm.
See manual for pipe extended version details. (Pipe is customer supplied.)
SITRANS LVS200, dimensions in mm (inch)
Siemens FI 01 · Update 05/2016
4/115
4
© Siemens AG 2016
Level Measurement
Point level measurement - Vibrating switches
SITRANS LVS200
■ Schematics
FSH/FSL adjustment
LED
Universal voltage (DPDT relay)
3-wire PNP
Sensitivity adjustment
(B=factory setting,
A=decreased sensitivity)
B
FSL
Alarm output
relay
1 2
FSH
A
1
N
7
9
8
1
2
3
PE +
-
DC
Terminal 1: +, terminal 2: 18 ... 50 V DC, +10 %, 1.5 W
DC
Terminal 1: +, terminal 2: 19 ... 55 V DC, +10 %, 2 W
NAMUR IEC 60947-5-6 8/16 mA or 4 ... 20 mA
AC
Terminal 1: L, terminal 2: N
19 ... 230 V AC, +10 %,
50 ... 60 Hz, 1.5 VA
DC
Terminal 1: +, terminal 2: 19 ... 230 V DC, +10 %, 1 W
SITRANS LVS200 connections
4/116
5
Signal output
PE + L N
AC
Terminal 1: L, terminal 2: N
19 ... 230 V AC, +10 %,
50 ... 60 Hz, 18 VA
Protective
earth
terminal
2-wire
PE +
L
4
Load
L N
19 ... 230 V AC or
+/- 19 ... 55 V DC
2
3
3 4 5
4
1
2
Siemens FI 01 · Update 05/2016
1
2
1
2
DC
terminal 1: +, terminal 2: 2.5 ... 36 V DC, + 0 %
Approx. 7 ... 9 V DC,
intrinsically safe
(IEC 60947-5-6)
PE +
L
N
PE +
L
N