© Siemens AG 2016 Level Measurement Point level measurement - Vibrating switches SITRANS LVS200 ■ Overview ■ Application The standard LVS200 detects high, low, or demand levels of dry bulk solids in bins, silos, or hoppers. The liquid/solid interface version can also detect settled solids within liquids or solids within confined spaces such as feed pipes. It is designed to ignore liquids in order to detect the interface between a solid and a liquid. A pipe extension version is available with either the standard or liquid/solid interface electronics and fork, separated by a customer supplied 1 inch pipe. SITRANS LVS200 has an optional 4 to 20 mA output for monitoring buildup on the fork to determine when preventative maintenance should be performed in sticky applications. The LVS200 has a compact design and can be top, side or angle mounted. The vibrating fork design ensures the tines are kept clean. The unique design of the fork and crystal assembly eliminates false high level readings even if tines become damaged. SITRANS LVS200 is a vibrating point level switch for high, low, or demand level detection of bulk solids. ■ Benefits • • • • High resistance to mechanical forces Strong vibration resistance to high bulk material loads Rotatable enclosure for convenient wiring Suitable for low density material: standard version, 20 g/l (1.3 lb/ft3); liquid/solid interface version, 50 g/l (3 lb/ft3) and low density option min. 5 g/l (0.3 lb/ft3) • Customer desired extensions up to 20 000 mm (787 inch) • Optional detection of solids within liquid • Durable short fork option with 165 mm (6.5 inch) insertion length A signal from the electronic circuit excites a crystal in the probe causing the fork to vibrate. If the fork is covered by material, the change in vibration is detected by the electronic circuitry which causes the relay to change state after a one second delay. When the fork is free from material pressure, full vibration resumes and the relay reverts to its normal condition. • Key Applications: dry bulk solids in bins, silos, hoppers or settled solids within liquids (interface version) Siemens FI 01 · Update 05/2016 4/107 4 © Siemens AG 2016 Level Measurement Point level measurement - Vibrating switches SITRANS LVS200 ■ Technical specifications Medium conditions Mode of operation Measuring principle Vibrating point level switch • Process temperature Input Measured variable High, low, and demand Measuring frequency • Standard 125 Hz • Liquid/solid interface and short fork 350 Hz version PNP Open collector: Permanent load max. 0.4 A, short-circuit and overload protected Turn-on voltage: max. 50 V (reverse protection) 2-wire without contact Load current: • Min. 10 mA • Max. 500 mA permanent • Max. 2A < 200 ms • Max. 5A < 50 ms Voltage drop on the electronic module: max. 7 V with closed electric circuit Cut-off current with open electric circuit: max. 5 mA Relays • Version with 1 relay • Version with 2 relays • Max. enclosure surface temperature 90 °C (194 °F) (Category 2D) • From loss of vibration: approximately 1 second • From resumption of vibration: approximately 1 ... 2 seconds Signal delay • Probe uncovered to covered: approximately 1 second • Probe covered to uncovered: approximately 1 ... 2 seconds Relay fail-safe High or low, switch selectable Alarm output • Relay 8 A at 250 V AC, non-inductive • Relay 5 A at 30 V DC, non-inductive mA output • Resolution 8/16 mA or 4 ... 20 mA 4 ... 20 mA ± 0.1 mA Sensitivity High or low, switch selectable Rated operating conditions Installation conditions • Location • Pressure (vessel) Max. 10 bar g (145 psi g) European Pressure Directive 2014/68/EU: Category 1 • Minimum material density • Standard version: approx. 20 g/l (1.2 lb/ft3) • Liquid/solid interface version: approx. 50 g/l (3 lb/ft3) • Optional low density version: approx. 5 g/l (0.3 lb/ft3) Design Material • Enclosure Indoor/outdoor Ambient conditions • Ambient temperature -40 ... +60 °C (-40 ... +140 °F) • Installation category III • Pollution degree 2 Siemens FI 01 · Update 05/2016 Epoxy coated aluminum Process connection • Thread 1½" NPT [(Taper), ANSI/ASME B1.20.1], R ½" [(BSPT), EN 10226], and flange options • Optional sliding bushing with 2" NPT [(Taper), ANSI/ASME B1.20.1] or BSP thread • Thread material: stainless steel 303 (1.4301) Tine material Stainless steel 316L (1.4404), PTFE-coated tines are available upon special request Degree of protection IP65/Type 4/NEMA 4 Conduit entry 2 x M20 x 1.5 or 2 x ½" NPT Weight • Standard version, no extensions: approx. 2.0 kg (4.4 lb) • Solids/liquids version, no extensions: approx. 1.9 kg (4.2 lb) Power supply • 19 ... 230 V AC, +10 %, 50 ... 60 Hz, 8 VA • 19 ... 55 V DC, +10 %, 1.5 W SPDT relay DPDT relay Relay delay 4/108 • Max. threaded bushing temperature 60 °C (140 °F) • Max. extension surface temperature 150 °C (302 °F) (Category 1D) Output 4 • All except CSA Class II, Group G: -40 ... +150 °C (-40 ... +302 °F) • CSA Class II, Group G: -40 ... +140 °C (-40 ... +284 °F), CSA temperature code T3B Certificates and approvals • • • • • • CSA/FM General Purpose CE CSA/FM Dust Ignition Proof RCM ATEX II 1/2 D CSA/FM IS Class I, II, III Div. 1, Groups A, B, C, D, E, F, G, FM Class I, Aex ia IIC, CSA Class I, Ex ia IIC, available only with power supply options 5 and 6 • ATEX II 1G and 1/2 G Eex ia IIC; ATEX II 1D and 1/2 D, available only with power supply option 5 © Siemens AG 2016 Level Measurement Point level measurement - Vibrating switches SITRANS LVS200 Selection and Ordering data Article No. Selection and Ordering data Article No. SITRANS LVS200, standard SITRANS LVS200 is a vibrating point level switch for high, low, or demand level detection of bulk solids. 7ML5731- SITRANS LVS200, standard SITRANS LVS200 is a vibrating point level switch for high, low, or demand level detection of bulk solids. 7ML5731- 7 7 7 7 7 - 77 A 0 Click on the Article No. for the online configuration in the PIA Life Cycle Portal. Stainless steel 316L (1.4404) Standard length, 235 mm (9.25 inch) Power supply 19 ... 230 V AC, 19 ... 55 V DC, one relay output (SPDT)1) 19 ... 230 V AC, 19 ... 55 V DC, two relay outputs (DPDT)1) 18 ... 50 V DC PNP1) Add Order code Y01 and plain text: "Insertion length ... mm" 1 2 3 4 19 ... 230 V AC/DC without contact, 2-wire loop powered1) 7 ... 9 V DC (requires NAMUR switch amplifier) NAMUR IEC 60947-5-6, 2-wire2) 8/16 mA or 4 ... 20 mA; 12.5 ... 35 V DC, 2-wire3) 5 6 19 ... 230 V AC, 19 ... 55 V DC, one relay output } 7 (SPDT) basic version4)5) Process temperature Without temperature isolator } With temperature isolator Separated enclosure - cable length 1.5 m (4.92 ft) [max. temperature process 150 °C (302 °F)/ max. temperature electronics 60 °C (140 °F)] Separated enclosure - cable length 4.0 m (13.12 ft) [max. temperature process150 °C (302 °F)/ max. temperature electronics 60 °C (140 °F)] A B C Process connection Threaded R 1½" [(BSPT), EN 10226] 1½" NPT [(Taper), ANSI/ASME B1.20.1] G 2" [(BSPP), EN ISO 228-1], sliding sleeve [min. length 500 mm (19.69 inch)]6) } } D 2" ASME 150 lb B16.5 3" ASME 150 lb B16.5 4" ASME 150 lb B16.5 G H J 2" Tri-clamp (DN 50) ISO 2852 K Extension length Stainless steel 304 (1.4301) Standard length, 235 mm (9.25 inch) E F } 32 33 34 35 1 251 ... 1 500 mm (49.25 ... 59.06 inch) 1 501 ... 1 750 mm (59.09 ... 68.90 inch) 1 751 ... 2 000 mm (68.94 ... 78.74 inch) 36 37 38 2 001 ... 2 250 mm (78.78 ... 88.58 inch) 2 251 ... 2 500 mm (88.62 ... 98.43 inch) 2 501 ... 2 750 mm (98.46 ... 108.27 inch) 2 751 ... 3 000 mm (108.31 ... 118.11 inch) 41 42 43 44 3 001 ... 3 250 mm (118.15 ... 127.95 inch) 3 251 ... 3 500 mm (127.99 ... 137.80 inch) 3 501 ... 3 750 mm (137.83 ... 147.64 inch) 3 751 ... 4 000 mm (147.68 ... 157.48 inch) 45 46 47 48 } Approvals CSA/FM Dust Ignition Proof, RCM } ATEX II 1/2 D, RCM } CSA/FM General Purpose, RCM, CE CE, RCM CSA/FM IS Class I, II, III Div. 1, Groups A, B, C, D, E, F, G, FM Class I, Aex ia IIC, CSA Class I, Ex ia IIC, RCM ATEX II 1G and 1/2G Eex ia IIC; ATEX II 1D and 1/2D, RCM IEC-Ex t IIIC Da/Db EAC Ex ta/tb IIIC Da/Db, Ex ta IIIC Da EAC Ex Ga/Gb Ex ia IIC, 0Ex ia IIC Ga; Ex ta/tb IIIC Da/Db, Ex ta IIIC Da A B C 2" NPT [(Taper), ANSI/ASME B1.20.1], sliding sleeve [min. length 500 mm (19.69 inch)]6) Flanged DN 100 PN 6, EN 1092-17) DN 100 PN 16, EN 1092-1 31 300 ... 500 mm (11.81 ... 19.69 inch) 501 ... 750 mm (19.72 ... 29.53 inch) 751 ... 1 000 mm (29.57 ... 39.37 inch) 1 001 ... 1 250 mm (39.41 ... 49.21 inch) Material process connection/extension Stainless steel threads 304 (1.4301), flanges 321 (1.4541), Tri-clamp 304 (1.4301)8) Stainless steel 316L (1.4404)9) D 7 7 7 7 7 - 77 A 0 1) Available with Approval options A ... D, G only 2) Available with Approval options D, E, F only 3) Available with Approval options B, D, G only 4) Available with configurations 7ML5731-7AA11-1BA0 or 7ML5731-7AB11-1AA0 only 5) Basic version is cost effective and offers fast delivery 6) Not available with extension length options 11, 12, 31, 32 7) Max. 6 bar (87 psi) 8) Available with option extension length 11 ... 28 9) Available with option extension length 31 … 48 11 Add Order code Y01 and plain text: "Insertion length ... mm" • 300 ... 500 mm (11.81 ... 19.69 inch) • 501 ... 750 mm (19.72 ... 29.53 inch) • 751 ... 1 000 mm (29.57 ... 39.37 inch) 12 13 14 • 1 001 ... 1 250 mm (39.41 ... 49.21 inch) • 1 251 ... 1 500 mm (49.25 ... 59.06 inch) • 1 501 ... 1 750 mm (59.09 ... 68.90 inch) 15 16 17 • 1 751 ... 2 000 mm (68.94 ... 78.74 inch) • 2 001 ... 2 250 mm (78.78 ... 88.58 inch) • 2 251 ... 2 500 mm (88.62 ... 98.43 inch) 18 21 22 • 2 501 ... 2 750 mm (98.46 ... 108.27 inch) • 2 751 ... 3 000 mm (108.31 ... 118.11 inch) • 3 001 ... 3 250 mm (118.15 ... 127.95 inch) 23 24 25 • 3 251 ... 3 500 mm (127.99 ... 137.80 inch) • 3 501 ... 3 750 mm (137.83 ... 147.64 inch) • 3 751 ... 4 000 mm (147.68 ... 157.48 inch) 26 27 28 4 1 2 A B C D E F G H J We can offer shorter delivery times for configurations designated with the Quick Ship Symbol . For details see page 9/5 in the appendix. } Available ex stock. For details see page 9/5 in the appendix. Siemens FI 01 · Update 05/2016 4/109 © Siemens AG 2016 Level Measurement Point level measurement - Vibrating switches SITRANS LVS200 Order code Selection and Ordering data Article No. 7ML5732- Total insertion length: Enter the total insertion length in plain text description, max. 4 000 mm (157.48 inch) Y01 SITRANS LVS200, short fork for liquids/ solids interface Vibrating point level switch for solids or solids within liquid interface applications, and high load applications with short insertion requirements Stainless steel tag [100 x 45 mm (3.94 x 1.77 inch)]: Measuring-point number/identification (max. 27 characters); specify in plain text Y14 Enhanced sensitivity > 5 g/l via electronics and increased insertion length of 25 mm (0.98 inch)3) K05 Enhanced sensitivity < 5 g/l via electronics, increased insertion length of 25 mm (0.98 inch), and increased aluminum fork width1)3) G01 Signal bulb inserted in M20 cable gland2) A20 Selection and Ordering data Further Designs Please add "-Z" to Article No. and specify Order code(s). 4 NAMUR 8/16 mA switch amplifiers available, contact factory for pricing Operating Instructions Article No. Multi-language 7ML1998-5FT63 Note: the Operating Instructions should be ordered as a separate line on the order. All literature is available to download for free, in a range of languages, at http://www.siemens.com/ processinstrumentation/documentation This device is shipped with the Siemens Level and Weighing manual DVD containing the ATEX Quick Start and Operating Instructions library. Spare Parts Replacement Electronics Module (125 Hz) [19 ... 230 V AC, 19 ... 55 V DC, one relay output (SPDT)] 7ML1830-1KL Replacement Electronics Module (125 Hz) [19 ... 230 V AC, 19 ... 55 V DC, two relay output (DPDT)] A5E35525363 Sliding sleeve, 2" BSP (ISO 228) 7ML1830-1JM Sliding sleeve, 2" NPT (ASME B1.20.1) 7ML1830-1JN Namur Isolator switch amplifier relay output KFD2-SR2-Ex1.W A5E35667901 Available ex stock For details see page 9/5 in the appendix. SITRANS LVS200, standard, power supply 7, process temperature A, process connection A, extension length 11, material process connection/ extension 1, and approval B 7ML57317AA11-1BA0 SITRANS LVS200, standard, power supply 7, process temperature A, process connection B, extension length 11, material process connection/ extension 1, and approval A 7ML57317AB11-1AA0 1) Available only with power supply 1 and Approval C, D and with Process connection flange E ... J 2) Available with Approval option D only 3) K05 and G01 are not available together 4/110 Siemens FI 01 · Update 05/2016 77 7 77 - 77 A 0 Click on the Article No. for the online configuration in the PIA Life Cycle Portal. Power supply 19 ... 230 V AC, 19 ... 55 V DC, one relay output (SPDT) 19 ... 230 V AC, 19 ... 55 V DC, two relay outputs (DPDT) 18 ... 50 V DC PNP 19 ... 230 V AC/DC without contact, 2-wire loop powered 8/16 mA or 4 ... 20 mA; 12.5 ... 35 V DC, 2-wire1) 1 2 3 4 5 Process temperature Without temperature isolator With temperature isolator Separated enclosure - cable length 1.5 m (4.92 ft) [max. temperature process 150 °C (302 °F)/ max. temperature electronics 60 °C (140 °F)] Separated enclosure - cable length 4.0 m (13.12 ft) [max. temperature process 150 °C (302 °F)/ max. temperature electronics 60 °C (140 °F)] Process connection Threaded R 1½" [(BSPT), EN 10226] 1½" NPT [(Taper), ANSI/ASME B1.20.1] G 2" [(BSPP), EN ISO 228-1], sliding sleeve [min. length 500 mm (19.69 inch)]2) 2" NPT [(Taper), ANSI/ASME B1.20.1], sliding sleeve [min. length 500 mm (19.69 inch)]2) Flanged DN 100 PN 6, EN 1092-13) DN 100 PN 16, EN 1092-1 A B C D A B C D E F G H J K 2" ASME 150 lb B16.5 3" ASME 150 lb B16.5 4" ASME 150 lb B16.5 2" Tri-clamp (DN 50) ISO 2852 Extension length Stainless steel 304 (1.4301) Standard length, 165 mm (6.50 inch) 11 Add Order code Y01 and plain text: "Insertion length ... mm" 200 ... 500 mm (7.87 ... 19.69 inch) 501 ... 750 mm (19.72 ... 29.53 inch) 751 ... 1 000 mm (29.57 ... 39.37 inch) 12 13 14 1 001 ... 1 250 mm (39.41 ... 49.21 inch) 1 251 ... 1 500 mm (49.25 ... 59.06 inch) 1 501 ... 1 750 mm (59.09 ... 68.90 inch) 15 16 17 1 751 ... 2 000 mm (68.94 ... 78.74 inch) 2 001 ... 2 250 mm (78.78 ... 88.58 inch) 2 251 ... 2 500 mm (88.62 ... 98.43 inch) 18 21 22 2 501 ... 2 750 mm (98.46 ... 108.27 inch) 2 751 ... 3 000 mm (108.31 ... 118.11 inch) 3 001 ... 3 250 mm (118.15 ... 127.95 inch) 23 24 25 3 251 ... 3 500 mm (127.99 ... 137.80 inch) 3 501 ... 3 750 mm (137.83 ... 147.64 inch) 3 751 ... 4 000 mm (147.68 ... 157.48 inch) 26 27 28 © Siemens AG 2016 Level Measurement Point level measurement - Vibrating switches SITRANS LVS200 Selection and Ordering data Article No. Selection and Ordering data SITRANS LVS200, short fork for liquids/ solids interface Vibrating point level switch for solids or solids within liquid interface applications, and high load applications with short insertion requirements 7ML5732- Further Designs 77 7 77 - 77 A 0 Please add "-Z" to Article No. and specify Order code(s). Stainless steel 316L (1.4404) Standard length, 165 mm (6.50 inch) Add Order code Y01 and plain text: "Insertion length ... mm" 200 ... 500 mm (7.87 ... 19.69 inch) 501 ... 750 mm (19.72 ... 29.53 inch) 751 ... 1 000 mm (29.57 ... 39.37 inch) 31 32 33 34 1 001 ... 1 250 mm (39.41 ... 49.21 inch) 1 251 ... 1 500 mm (49.25 ... 59.06 inch) 1 501 ... 1 750 mm (59.09 ... 68.90 inch) 1 751 ... 2 000 mm (68.94 ... 78.74 inch) 35 36 37 38 2 001 ... 2 250 mm (78.78 ... 88.58 inch) 2 251 ... 2 500 mm (88.62 ... 98.43 inch) 2 501 ... 2 750 mm (98.46 ... 108.27 inch) 41 42 43 2 751 ... 3 000 mm (108.31 ... 118.11 inch) 3 001 ... 3 250 mm (118.15 ... 127.95 inch) 3 251 ... 3 500 mm (127.99 ... 137.80 inch) 44 45 46 3 501 ... 3 750 mm (137.83 ... 147.64 inch) 3 751 ... 4 000 mm (147.68 ... 157.48 inch) 47 48 Material process connection/extension Stainless steel threads 304 (1.4301), flanges 321(1.4541), Tri-clamp 304 (1.4301)4) Stainless steel 316L (1.4404)5) 1) Available with Approval options B, D, E only 2) Not available with extension length options 11,12, 31, 32 3) Max. 6 bar (87psi) 4) Available with option extension length 11 ... 28 5) Available with option extension length 31 … 48 Total insertion length: Enter the total insertion length in plain text description, max. 4 000 mm (147.48 inch) Y01 Stainless steel tag [100 x 45 mm (3.94 x 1.77 inch)]: Measuring-point number/identification (max. 27 characters); specify in plain text Y14 Signal bulb inserted in M20 cable gland1) A20 Adjustable sensitivity (by potentiometer) for solids/ liquids interface detection1)2) G02 Operating Instructions Article No. Multi-language 7ML1998-5FT63 4 Note: the Operating Instructions should be ordered as a separate line on the order. All literature is available to download for free, in a range of languages, at http://www.siemens.com/ processinstrumentation/documentation This device is shipped with the Siemens Level and Weighing manual DVD containing the ATEX Quick Start and Operating Instructions library. Spare Parts 1 2 Approvals CSA/FM Dust Ignition Proof, RCM ATEX II 1/2 D, RCM CSA/FM General Purpose, RCM, CE CE, RCM IEC-Ex t IIIC Da/Db ATEX II 1G and 1/2G Eex ia IIC; ATEX II 1D and 1/2D, CE, RCM EAC Ex ta/tb IIIC Da/Db, Ex ta IIIC Da EAC Ex Ga/Gb Ex ia IIC, 0Ex ia IIC Ga; Ex ta/tb IIIC Da/Db, Ex ta IIIC Da Order code A B C D E F Replacement Electronics Module (125 Hz) [19 ... 230 V AC, 19 ... 55 V DC, two relay output (DPDT)] A5E35525363 Replacement Electronics Module (350 Hz) [19 ... 230 V AC, 19 ... 55 V DC, one relay output (SPDT)] 7ML1830-1KM Sliding sleeve, 2" BSP (ISO 228) 7ML1830-1JM Sliding sleeve, 2" NPT (ASME B1.20.1) 7ML1830-1JN 1) Available with Approval option D only 2) Available with power supply option 1 only G H We can offer shorter delivery times for configurations designated with the Quick Ship Symbol . For details see page 9/5 in the appendix. Siemens FI 01 · Update 05/2016 4/111 © Siemens AG 2016 Level Measurement Point level measurement - Vibrating switches SITRANS LVS200 Selection and Ordering data Article No. Selection and Ordering data SITRANS LVS200, pipe extension Vibrating point level switch for high or low levels of bulk solids Extended using 1" pipe extension (customer supplied) 7ML5733- Further Designs 77 7 77 - 77 A 0 Please add "-Z" to Article No. and specify Order code(s). Total insertion length: Enter the total insertion length in plain text description, max. 3 800 mm (149.61 inch) Y01 Stainless steel tag [100 x 45 mm (3.94 x 1.77 inch)]: Measuring-point number/identification (max. 27 characters); specify in plain text Y14 2 Enhanced sensitivity > 5 g/l via electronics and increased insertion length of 25 mm (0.98 inch)5) K05 3 Enhanced sensitivity < 5 g/l via electronics, increased insertion length of 25 mm (0.98 inch) and increased aluminum fork width1)4)5) G01 5 Adjustable sensitivity (by potentiometer) for solids/ liquids interface detection2)3)4) G02 6 Signal bulb inserted in M20 cable gland2) A20 Operating Instructions Article No. Multi-language 7ML1998-5FT63 Click on the Article No. for the online configuration in the PIA Life Cycle Portal. Power supply 19 ... 230 V AC, 19 ... 55 V DC, one relay output (SPDT)1) 19 ... 230 V AC, 19 ... 55 V DC, two relay outputs (DPDT)1) 18 ... 50 V DC PNP1) 4 19 ... 230 V AC/DC without contact, 2-wire loop powered1) 7 ... 9 V DC (requires NAMUR switch amplifier) NAMUR IEC 60947-5-6, 2-wire2) 8/16 mA or 4 ... 20 mA; 12.5 ... 35 V DC, 2-wire3) Process temperature Up to 150 °C (302 °F) 1 4 A Process connection Threaded R 1½" [(BSPT), EN 10226] 1½" NPT [(Taper), ANSI/ASME B1.20.1] Note: the Operating Instructions should be ordered as a separate line on the order. All literature is available to download for free, in a range of languages, at http://www.siemens.com/ processinstrumentation/documentation This device is shipped with the Siemens Level and Weighing manual DVD containing the ATEX Quick Start and Operating Instructions library. A B Flanged DN 100 PN 6, EN 1092-14) DN 100 PN 16, EN 1092-1 C D 2" ASME 150 lb B16.5 3" ASME 150 lb B16.5 4" ASME 150 lb B16.5 2" Tri-clamp (DN 50) ISO 2852 E F G K Process connection material Stainless steel threads 304 (1.4301), flanges 321 (1.4541), Tri-clamp 304 (1.4301) Stainless steel 316L (1.4404) Extension length Customer supplied 1" pipe extension Length: 300 ... 3 800 mm (11.81 ... 149.61 inch) Spare Parts 1 2 1 Application type Dry bulk solids (125 Hz) Liquids/solids interface (350 Hz) Approvals CSA/FM Dust Ignition Proof, RCM ATEX II 1/2 D, RCM CSA/FM General Purpose, RCM, CE CE, RCM CSA/FM IS Class I, II, III Div. 1, Groups A, B, C, D, E, F, G, FM Class I, Aex ia IIC, CSA Class I, Ex ia IIC, RCM ATEX II 1G and 1/2G Eex ia IIC; ATEX II 1D and 1/2D, RCM IEC-Ex t IIIC Da/Db EAC Ex ta/tb IIIC Da/Db, Ex ta IIIC Da EAC Ex Ga/Gb Ex ia IIC, 0Ex ia IIC Ga; Ex ta/tb IIIC Da/Db, Ex ta IIIC Da 1) Available with Approval options A, B, C, D, G only 2) Available with approval options D, F, J and application type 1 only 3) Available with Approval options B, D, G only 4) Max. 6 bar (87 psi) 4/112 Siemens FI 01 · Update 05/2016 Order code 1 2 A B C D E F G H J Replacement Electronics Module (125 Hz) [19 ... 230 V AC, 19 ... 55 V DC, one relay output (SPDT)] 7ML1830-1KL Replacement Electronics Module (125 Hz) [19 ... 230 V AC, 19 ... 55 V DC, two relay output (DPDT)] A5E35525363 Replacement Electronics Module (350 Hz) [19 ... 230 V AC, 19 ... 55 V DC, one relay output (SPDT)] 7ML1830-1KM NAMUR Isolated switch amplifier Relay output KFD2-SR2-Ex1.W A5E35667901 1) Available only with power supply 1 and Approvals C, D, and with Process connection flange C … G 2) Available with approval options D only 3) Available with power supply option 1 only and application type 2 4) Not available with option K05 5) Available with Application type 1 only © Siemens AG 2016 Level Measurement Point level measurement - Vibrating switches SITRANS LVS200 Selection and Ordering data Article No. Selection and Ordering data Article No. SITRANS LVS200, cable extended Vibrating point level switch for high or low level detection of bulk solids materials 7ML5734- 7ML5734- 7 7 7 7 7 - 77 A 0 SITRANS LVS200, cable extended Vibrating point level switch for high or low level detection of bulk solids materials 1 Approvals CSA/FM Dust Ignition Proof, RCM ATEX II 1/2 D, RCM CSA/FM General Purpose, RCM, CE Click on the Article No. for the online configuration in the PIA Life Cycle Portal. Power supply 19 ... 230 V AC, 19 ... 55 V DC, one relay output (SPDT)1) 19 ... 230 V AC, 19 ... 55 V DC, two relay outputs (DPDT)1) 18 ... 50 V DC PNP1) 19 ... 230 V AC/DC without contact, 2-wire loop powered1) 7 ... 9 V DC (requires NAMUR switch amplifier) NAMUR IEC 60947-5-6, 2-wire2)5) 8/16 mA or 4 ... 20 mA; 12.5 ... 35 V DC, 2-wire3) Process temperature Up to 80 °C (176 °F) Process connection Threaded R 1½" [(BSPT), EN 10226] (1.4301/304) 1½" NPT [(Taper), ANSI/ASME B1.20.1] (1.4301/304) CE, RCM CSA/FM IS Class I, II, III Div. 1, Groups A, B, C, D, E, F, G, FM Class I, Aex ia IIC, CSA Class I, Ex ia IIC, RCM ATEX II 1G and 1/2G Eex ia IIC; ATEX II 1D and 1/2D, RCM6) IEC-Ex t IIIC Da/Db EAC Ex ta/tb IIIC Da/Db, Ex ta IIIC Da EAC Ex Ga/Gb Ex ia IIC, 0Ex ia IIC Ga; Ex ta/tb IIIC Da/Db, Ex ta IIIC Da 2 3 4 5 6 A A B Flanged DN 100 PN 6, EN 1092-1 (1.4541/321)4) DN 100 PN 16, EN 1092-1 (1.4541/321) C D 2" ASME 150 lb B16.5 (1.4541/321) 3" ASME 150 lb B16.5 (1.4541/321) 4" ASME 150 lb B16.5 (1.4541/321) E F G Extension length 750 ... 1 000 mm (29.5 ... 39.4 inch) [max. length 20 000 mm (787.4 inch), not with Power supply option 5 (max. 10 000 mm, 393.7 inch)]8) 1) Available with Approval options A, B, C, D, G only 2) Available with Approval options D, E, and F only. Not available for application type 2 "Liquids/solids interface". 3) Available with Approval option D only 4) Max. 6 bar (87 psi) 5) Not available with application type option 2 6) Not available with Power supply option 5 7) Cable length is limited to 7 000 mm (275.59 inch) 8) Available A B C D E F G H J with power supply options 1 … 4, and 6 10 Add Order code Y01 and plain text: "Insertion length ... mm" 1 001 ... 2 000 mm (39.41 ... 78.74 inch) 2 001 ... 3 000 mm (78.78 ... 118.11 inch) 3 001 ... 4 000 mm (118.15 ... 157.48 inch) 11 12 13 4 001 ... 5 000 mm (157.52 ... 196.85 inch) 5 001 ... 6 000 mm (196.89 ... 236.22 inch) 6 001 ... 7 000 mm (236.26 ... 275.59 inch) 14 15 16 7 001 ... 8 000 mm (275.63 ... 314.96 inch)5) 8 001 ... 9 000 mm (315 ... 354.33 inch)5) 9 001 ... 10 000 mm (354.37 ... 393.70 inch)5) 17 18 20 10 001 ... 11000 mm (393.74 ... 433.07 inch)5)6) 11 001 ... 12 000 mm (433.11 ... 472.44 inch)5)6) 12 001 ... 13 000 mm (472.48 ... 511.81 inch)5)6) 21 22 23 13 001 ... 14 000 mm (511.85 ... 551.18 inch)5)6) 14 001 ... 15 000 mm (551.22 ... 590.55 inch)5)6) 15 001 ... 16 000 mm (590.59 ... 629.92 inch)5)6) 24 25 26 16 001 ... 17 000 mm (629.96 ... 669.29 inch)5)6) 17 001 ... 18 000 mm (669.33 ... 708.66 inch)5)6) 18 001 ... 19 000 mm (708.70 ... 748.03 inch)5)6) 19 001 ... 20 000 mm (748.07 ... 787.40 inch)5)6) 27 28 30 31 Application type Dry bulk solids (125 Hz) Liquid/solids interface (350 Hz)7) 7 7 7 7 7 - 77 A 0 1 2 Siemens FI 01 · Update 05/2016 4/113 4 © Siemens AG 2016 Level Measurement Point level measurement - Vibrating switches SITRANS LVS200 Selection and Ordering data Order code Further Designs Please add "-Z" to Article No. and specify Order code(s). 4 Enter the total insertion length in plain text description, max. 20 000 mm (787.40 inch) Y01 Stainless steel tag [100 x 45 mm (3.94 x 1.77 inch)]: Measuring-point number/identification (max. 27 characters); specify in plain text Y14 Enhanced sensitivity > 5 g/l via electronics and increased insertion length of 25 mm (0.98 inch)5) K05 Enhanced sensitivity < 5 g/l via electronics and increased insertion length of 25 mm (0.98 inch) and increased aluminum fork width1)4) G01 Adjustable sensitivity (by potentiometer) for solids/ liquids interface detection2)3)4) G02 Signal bulb inserted in M20 cable gland2) A20 Operating Instructions Article No. Multi-language 7ML1998-5FT63 Note: the Operating Instructions should be ordered as a separate line on the order. All literature is available to download for free, in a range of languages, at http://www.siemens.com/ processinstrumentation/documentation This device is shipped with the Siemens Level and Weighing manual DVD containing the ATEX Quick Start and Operating Instructions library. Spare Parts Replacement Electronics Module (125 Hz) [19 ... 230 V AC, 19 ... 55 V DC, one relay output (SPDT)] 7ML1830-1KL Replacement Electronics Module (125 Hz) [19 ... 230 V AC, 19 ... 55 V DC, two relay output (DPDT)] A5E35525363 Replacement Electronics Module (350 Hz) [19 ... 230 V AC, 19 ... 55 V DC, one relay output (SPDT)] 7ML1830-1KM NAMUR Isolated switch amplifier Relay output KFD2-SR2-Ex1.W A5E35667901 1) Available only with power supply 1 and Approvals C, D, and with process connection flange C … G 2) Available with Approval options D only 3) Available with power supply option 1 and application type 2 only 4) Not available with option K05 5) Available with Application type 1 only 4/114 Siemens FI 01 · Update 05/2016 © Siemens AG 2016 Level Measurement Point level measurement - Vibrating switches SITRANS LVS200 150 (5.91) Tine orientation marking Threaded bushing [max. temp. 80 °C (176 °F)] Optional sliding bushing* Thread length BSP: 20.5 (0.81) NPT: 24 (0.94) 42 (1.67) Tine 165 (6.5): Compact solids/ liquids interface model 230 (9.0): Compact standard version 300 ... 4 000 (11.81 ... 157): Customer-specified rigid extension 42 (1.67) 100 (3.94) Solids/liquids interface model Tine 170 (6.69): Standard model 100 (3.94) Solids/liquids interface model 170 (6.69): Standard model Customer supplied process flange 195 (7.68) 60 (2.36) 700 ... 20 000 (27.56 ... 787)** View A-A A 75 (2.95) 120 (4.72) 60 (2.36) A 155 (6.1) ■ Dimensional drawings Notes: * The clamping screws of the sliding bushing must be tightened to 10 Nm. ** Cable version with liquids/solids interface model option length to 7 000 mm (275.59 inch) Cable version with NAMUR electronics length to 10 000 mm (393.7 inch) tightened to 10 Nm. See manual for pipe extended version details. (Pipe is customer supplied.) SITRANS LVS200, dimensions in mm (inch) Siemens FI 01 · Update 05/2016 4/115 4 © Siemens AG 2016 Level Measurement Point level measurement - Vibrating switches SITRANS LVS200 ■ Schematics FSH/FSL adjustment LED Universal voltage (DPDT relay) 3-wire PNP Sensitivity adjustment (B=factory setting, A=decreased sensitivity) B FSL Alarm output relay 1 2 FSH A 1 N 7 9 8 1 2 3 PE + - DC Terminal 1: +, terminal 2: 18 ... 50 V DC, +10 %, 1.5 W DC Terminal 1: +, terminal 2: 19 ... 55 V DC, +10 %, 2 W NAMUR IEC 60947-5-6 8/16 mA or 4 ... 20 mA AC Terminal 1: L, terminal 2: N 19 ... 230 V AC, +10 %, 50 ... 60 Hz, 1.5 VA DC Terminal 1: +, terminal 2: 19 ... 230 V DC, +10 %, 1 W SITRANS LVS200 connections 4/116 5 Signal output PE + L N AC Terminal 1: L, terminal 2: N 19 ... 230 V AC, +10 %, 50 ... 60 Hz, 18 VA Protective earth terminal 2-wire PE + L 4 Load L N 19 ... 230 V AC or +/- 19 ... 55 V DC 2 3 3 4 5 4 1 2 Siemens FI 01 · Update 05/2016 1 2 1 2 DC terminal 1: +, terminal 2: 2.5 ... 36 V DC, + 0 % Approx. 7 ... 9 V DC, intrinsically safe (IEC 60947-5-6) PE + L N PE + L N