TLV5619 2.7 V TO 5.5 V 12-BIT PARALLEL DIGITAL-TO-ANALOG CONVERTER WITH POWER DOWN SLAS172C – DECEMBER 1997 – REVISED APRIL 2000 D D D D D D D D D D D Single Supply 2.7-V to 5.5-V Operation ±0.4 LSB Differential Nonlinearity (DNL), ±1.5 LSB Integral Nonlinearity (INL) 12-Bit Parallel Interface Compatible With TMS320 DSP Internal Power On Reset Settling Time 1 µs Typ Low Power Consumption: – 8 mW for 5-V Supply – 4.3 mW for 3-V Supply Reference Input Buffers Voltage Output Monotonic Over Temperature Asynchronous Update applications D D D D D D D D Battery Powered Test Instruments Digital Offset and Gain Adjustment Battery Operated/Remote Industrial Controls Machine and Motion Control Devices Cordless and Wireless Telephones Speech Synthesis Communication Modulators Arbitrary Waveform Generation DW OR PW PACKAGE (TOP VIEW) 1 2 3 4 5 6 7 8 9 10 D2 D3 D4 D5 D6 D7 D8 D9 D10 D11 description The TLV5619 is a 12-bit voltage output DAC with a microprocessor and TMS320 compatible parallel interface. The 12 data bits are double buffered so that the output can be updated asynchronously using the LDAC pin. During normal operation, the device dissipates 8 mW at a 5-V supply and 4.3 mW at a 3-V supply. The power consumption can be lowered to 50 nW by setting the DAC to power-down mode. 20 19 18 17 16 15 14 13 12 11 D1 D0 CS WE LDAC PD GND OUT REFIN VDD The output voltage is buffered by a ×2 gain rail-to-rail amplifier, which features a Class A output stage to improve stability and reduce settling time. AVAILABLE OPTIONS PACKAGE TA SMALL OUTLINE (DW) TSSOP (PW) 0°C to 70°C TLV5619CDW TLV5619CPW – 40°C to 85°C TLV5619IDW TLV5619IPW – 40°C to 125°C TLV5619QDW — Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of Texas Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet. Copyright 2000, Texas Instruments Incorporated PRODUCTION DATA information is current as of publication date. Products conform to specifications per the terms of Texas Instruments standard warranty. Production processing does not necessarily include testing of all parameters. POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 1 TLV5619 2.7 V TO 5.5 V 12-BIT PARALLEL DIGITAL-TO-ANALOG CONVERTER WITH POWER DOWN SLAS172C – DECEMBER 1997 – REVISED APRIL 2000 functional block diagram REFIN 12 + _ D0 19 20 D1 1 D2 2 D3 3 D4 4 D5 5 D6 6 D7 7 D8 8 D9 9 D10 10 D11 Resistor String DAC 12 17 WE 12 Power-On Reset Select and Control Logic 18 CS 12-Bit DAC Latch 12-Bit Input Register 15 PD 16 LDAC Terminal Functions TERMINAL NAME CS D0 (LSB)–D11 (MSB) NO. I/O DESCRIPTION 18 I Chip select 19, 20, 1 – 10 I Parallel data input GND 14 LDAC 16 I Load DAC OUT 13 O Analog output PD 15 I When low, disables all buffer amplifier voltages to reduce supply current REFIN 12 I Voltage reference input VDD WE 11 2 17 Ground Positive power supply I Write enable POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 x2 13 OUT TLV5619 2.7 V TO 5.5 V 12-BIT PARALLEL DIGITAL-TO-ANALOG CONVERTER WITH POWER DOWN SLAS172C – DECEMBER 1997 – REVISED APRIL 2000 absolute maximum ratings over operating free-air temperature range (unless otherwise noted)† Supply voltage (VDD to GND) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 V Analog input voltage range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 0.3 V to VDD + 0.3 V Reference input voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . VDD + 0.3 V Digital input voltage range to GND . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 0.3 V to VDD + 0.3 V Operating free-air temperature range, TA: TLV5619C . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0°C to 70°C TLV5619I . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 40°C to 85°C TLV5619Q . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 40°C to 125°C Storage temperature range, Tstg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 65°C to 150°C Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 260°C † Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability. recommended operating conditions MIN NOM Supply voltage, VDD (5-V Supply) 4.5 5 5.5 V Supply voltage, VDD (3-V Supply) 2.7 3 3.3 V High-level digital input voltage, VIH Low-level digital input voltage, VIL VDD VDD 2 0 2.048 Reference voltage, Vref to REFIN terminal (3-V Supply) 0 1.024 Load resistance, RL 2 10 Load capacitance, CL 0.8 V VDD – 1.5 VDD – 1.5 V 0 V kΩ 100 TLV5619C UNIT V Reference voltage, Vref to REFIN terminal (5-V Supply) Operating free-air temperature, TA MAX pF 70 TLV5619I – 40 85 TLV5619Q – 40 125 °C NOTES: 1. The recommended operating levels for both VIH and VIL apply to all valid values of VDD. 2. Reference input voltages greater than VDD/2 will cause output saturation for large DAC codes. POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 3 TLV5619 2.7 V TO 5.5 V 12-BIT PARALLEL DIGITAL-TO-ANALOG CONVERTER WITH POWER DOWN SLAS172C – DECEMBER 1997 – REVISED APRIL 2000 electrical characteristics over recommended operating free-air temperature range, supply voltages, and reference voltages (unless otherwise noted) static DAC specifications PARAMETER EZS EG TEST CONDITIONS MIN MAX UNIT Resolution Vref(REFIN) = 2.048 V at 5 V, 1.024 V at 3 V Integral nonlinearity (INL) Vref(REFIN) = 2.048 V at 5 V, 1.024 V at 3 V, See Note 3 ± 1.5 ±4 LSB Differential nonlinearity (DNL) Vref(REFIN) = 2.048 V at 5 V, 1.024 V at 3 V, See Note 4 ± 0.4 ±1 LSB Zero-scale error (offset error at zero scale) Vref(REFIN) = 2.048 V at 5 V, 1.024 V at 3 V, See Note 5 ±3 ± 20 mV Zero-scale-error temperature coefficient Vref(REFIN) = 2.048 V at 5 V, 1.024 V at 3 V, See Note 6 3 Gain error Vref(REFIN) = 2.048 V at 5 V, 1.024 V at 3 V, See Note 7 ± 0.25 Gain error temperature coefficient Vref(REFIN) = 2.048 V at 5 V, 1.024 V at 3 V, See Note 8 1 12 Zero scale PSRR TYP Power supply rejection ratio Power-supply ppm/°C ± 0.5 % of FS voltage ppm/°C 65 See Notes 9 and 10 Gain bits dB 65 NOTES: 3. The relative accuracy or integral nonlinearity (INL), sometimes referred to as linearity error, is the maximum deviation of the output from the line between zero and full scale excluding the effects of zero code and full-scale errors. 4. The differential nonlinearity (DNL), sometimes referred to as differential error, is the difference between the measured and ideal 1 LSB amplitude change of any two adjacent codes. Monotonic means the output voltage changes in the same direction (or remains constant) as a change in the digital input code. 5. Zero-scale error is the deviation from zero voltage output when the digital input code is zero. 6. Zero-scale-error temperature coefficient is given by: EZS TC = [EZS (Tmax) – EZS (Tmin)]/Vref × 106/(Tmax – Tmin). 7. Gain error is the deviation from the ideal output (2 × Vref – 1 LSB) with an output load of 10 kΩ excluding the effects of the zero-error. 8. Gain temperature coefficient is given by: EG TC = [EG(Tmax) – EG (Tmin)]/Vref × 106/(Tmax – Tmin). 9. Zero-scale-error rejection ratio (EZS-RR) is measured by varying the VDD from 4.5 V to 5.5 V dc and measuring the proportion of this signal imposed on the zero-code output voltage. 10. Gain-error rejection ratio (EG-RR) is measured by varying the VDD from 4.5 V to 5.5 V dc and measuring the proportion of this signal imposed on the full-scale output voltage after subtracting the zero scale change. output specifications PARAMETER VO TEST CONDITIONS Voltage output range RL = 10 kΩ Output load regulation accuracy VO(OUT) = 4.096 V, 2.048 V IOSC(source) Output Out ut short circuit source current VO(OUT) = 0 V, Full scale code IO(source) Output Out ut source current 4 RL = 100 Ω POST OFFICE BOX 655303 MIN TYP 0 RL = 2 kΩ 0.1 5-V Supply 100 3-V Supply 25 5-V Supply 10 3-V Supply 10 • DALLAS, TEXAS 75265 MAX VDD–0.4 0.29 UNIT V % of FS voltage mA mA TLV5619 2.7 V TO 5.5 V 12-BIT PARALLEL DIGITAL-TO-ANALOG CONVERTER WITH POWER DOWN SLAS172C – DECEMBER 1997 – REVISED APRIL 2000 electrical characteristics over recommended operating free-air temperature range, supply voltages, and reference voltages (unless otherwise noted) reference input (REFIN) PARAMETER Vref Ri Reference input voltage Ci Reference input capacitance TEST CONDITIONS See Note 11 MIN TYP 0 Reference input resistance MAX UNIT VDD– 1.5 V 10 MΩ 5 pF Reference feed through REFIN = 1 Vpp at 1 kHz + 1.024 V dc (see Note 12) –60 dB Reference input bandwidth REFIN = 0.2 Vpp + 1.024 V dc at –3 dB 1.4 MHz NOTES: 11. Reference input voltages greater than VDD/2 will cause output saturation for large DAC codes. 12. Reference feedthrough is measured at the DAC output with an input code = 0x000 and a Vref(REFIN) input = 1.024 V dc + 1 Vpp at 1 kHz. digital inputs (D0 – D11, CS, WE, LDAC, PD) PARAMETER IIH IIL High-level digital input current Ci Input capacitance TEST CONDITIONS MIN TYP VI = VDD VI = 0 V Low-level digital input current MAX UNIT 1 µA –1 µA 8 pF power supply PARAMETER IDD Power supply current TEST CONDITIONS MIN No load, load All inputs 0 V or VDD TYP MAX 5-V Supply 1.6 3 3-V Supply 1.44 2.7 0.01 10 Power down supply current POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 UNIT mA µA 5 TLV5619 2.7 V TO 5.5 V 12-BIT PARALLEL DIGITAL-TO-ANALOG CONVERTER WITH POWER DOWN SLAS172C – DECEMBER 1997 – REVISED APRIL 2000 operating characteristics over recommended operating free-air temperature range, supply voltages, and reference voltages (unless otherwise noted) analog output dynamic performance PARAMETER SR ts S/N S/(N+D) TEST CONDITIONS CL = 100 pF, RL = 10 kΩ,, Code 32 to code 4095, Code 4095 to code 32, Vref(REFIN) = 2.048 V, 1.024 V,, VO from 10% to 90% 90% to 10% Output settling time (full scale) To ± 0.5 LSB, RL = 10 kΩ, CL = 100 pF, See Note 13 Glitch energy DIN = all 0s to all 1s Signal to noise fs = 480 kSPS, BW = 20 kHz, CL = 100 pF, fOUT = 1 kHz, RL = 10 kΩ TA = 25°C, See Note 14 Signal to noise + distortion fs = 480 kSPS, BW = 20 kHz kHz, CL = 100 pF, fOUT = 1 kHz, RL = 10 kΩ, kΩ TA = 25°C, See Note 14 Total harmonic distortion fs = 480 kSPS, BW = 20 kHz, CL = 100 pF, fOUT = 1 kHz, RL = 10 kΩ, TA = 25°C, See Note 14 Spurious free dynamic range fs = 480 kSPS, BW = 20 kHz, CL = 100 pF, fOUT = 1 kHz, RL = 10 kΩ, TA = 25°C, See Note 14 Slew rate MIN TYP 5-V Supply 8 12 V/µs 3-V Supply 6 9 V/µs 1 MAX 3 5 5-V Supply 65 78 5-V Supply 58 67 3-V Supply 58 69 –68 60 UNIT µs nV–s dB –60 72 NOTES: 13. Settling time is the time for the output signal to remain within ± 0.5 LSB of the final measured value for a digital input code change of 0x020 to 0x3DF or 0x3DF to 0x020. Limits are ensured by design and characterization, but are not production tested. 14. 1 kHz sinewave generated by DAC, reference voltage = 1.024 V at 3 V and 2.048 V at 5 V. 6 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 TLV5619 2.7 V TO 5.5 V 12-BIT PARALLEL DIGITAL-TO-ANALOG CONVERTER WITH POWER DOWN SLAS172C – DECEMBER 1997 – REVISED APRIL 2000 timing requirement digital inputs MIN tsu(CS-WE) tsu(D) Setup time, CS low before negative WE edge NOM MAX UNIT 13 ns Setup time, data ready before positive WE edge 9 ns th(D) tsu(WE-LD) Hold time, data held after positive WE edge 0 ns Setup time, positive WE edge before LDAC low 0 ns twh(WE) tw(LD) Pulse width, WE high 10 ns Pulse width, LDAC low 10 ns PARAMETER MEASUREMENT INFORMATION D(0–11) X Data X tsu(D) th(D) CS tsu(CE-WE) twh(WE) WE tsu(WE-LD) tw(LD) LDAC Figure 1. Timing Diagram POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 7 TLV5619 2.7 V TO 5.5 V 12-BIT PARALLEL DIGITAL-TO-ANALOG CONVERTER WITH POWER DOWN SLAS172C – DECEMBER 1997 – REVISED APRIL 2000 TYPICAL CHARACTERISTICS MAXIMUM OUTPUT VOLTAGE vs LOAD MAXIMUM OUTPUT VOLTAGE vs LOAD 3 5 VDD = 3 V, Vref = 1.2 V, Input Code = 4095 VDD = 5 V, Vref = 2 V, Input Code = 4095 2.5 VO – Output Voltage – V VO – Output Voltage – V 4 3 2 2 1.5 1 1 100 k 100 10 k 1k RL – Output Load – Ω 0.5 100 k 10 100 10 k 1k RL – Output Load – Ω Figure 3 Figure 2 TOTAL HARMONIC DISTORTION vs LOAD TOTAL HARMONIC DISTORTION vs FREQUENCY 0 VDD = 5 V, Vref = 2 V, Tone at 1 kHz VDD = 5 V THD – Total Harmonic Distortion – dB THD – Total Harmonic Distortion – dB 0 –20 –40 –60 –80 –10 –20 –30 –40 –50 –60 –70 –100 100 k –80 10 k 1k 100 RL – Output Load – Ω 10 0 5 10 15 Figure 5 POST OFFICE BOX 655303 20 25 f – Frequency – kHz Figure 4 8 10 • DALLAS, TEXAS 75265 30 35 TLV5619 2.7 V TO 5.5 V 12-BIT PARALLEL DIGITAL-TO-ANALOG CONVERTER WITH POWER DOWN SLAS172C – DECEMBER 1997 – REVISED APRIL 2000 TYPICAL CHARACTERISTICS SNRD – Signal-To-Noise Ratio + Distortion – dB SIGNAL-TO-NOISE + DISTORTION vs FREQUENCY 80 VDD = 5 V 70 60 50 40 30 20 10 0 0 5 10 15 20 25 30 35 f – Frequency – kHz DNL – Differential Nonlinearity – LSB Figure 6 1 0.8 0.6 0.4 0.2 0 –0.2 –0.4 –0.6 –0.8 –1 0 500 1000 1500 2000 2500 3000 3500 4000 Code Figure 7. Differential Nonlinearity POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 9 TLV5619 2.7 V TO 5.5 V 12-BIT PARALLEL DIGITAL-TO-ANALOG CONVERTER WITH POWER DOWN SLAS172C – DECEMBER 1997 – REVISED APRIL 2000 INL – Integral Nonlinearity – LSB TYPICAL CHARACTERISTICS 4 3 2 1.5 1 0.5 0 –0.5 –1 –1.5 –2 –3 –4 0 500 1000 1500 2000 2500 3000 Code Figure 8. Integral Nonlinearity POWER DOWN SUPPLY CURRENT vs TIME 1 I DD – Supply Current – mA 0.1 0.01 0.001 0.0001 0.00001 0.000001 0 100 200 300 400 500 t – Time – ms Figure 9 10 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 600 3500 4000 TLV5619 2.7 V TO 5.5 V 12-BIT PARALLEL DIGITAL-TO-ANALOG CONVERTER WITH POWER DOWN SLAS172C – DECEMBER 1997 – REVISED APRIL 2000 APPLICATION INFORMATION definitions of specifications and terminology integral nonlinearity (INL) The relative accuracy or integral nonlinearity (INL), sometimes referred to as linearity error, is the maximum deviation of the output from the line between zero and full scale excluding the effects of zero code and full-scale errors. differential nonlinearity (DNL) The differential nonlinearity (DNL), sometimes referred to as differential error, is the difference between the measured and ideal 1 LSB amplitude change of any two adjacent codes. Monotonic means the output voltage changes in the same direction (or remains constant) as a change in the digital input code. zero-scale error (EZS) Zero-scale error is defined as the deviation of the output from 0 V at a digital input value of 0. gain error (EG) Gain error is the error in slope of the DAC transfer function. signal-to-noise ratio + distortion (S/N+D) S/N+D is the ratio of the rms value of the output signal to the rms sum of all other spectral components below the Nyquist frequency, including harmonics but excluding dc. The value for S/N+D is expressed in decibels. spurious free dynamic range (SFDR) SFDR is the difference between the rms value of the output signal and the rms value of the largest spurious signal within a specified bandwidth. The value for SFDR is expressed in decibels. total harmonic distortion (THD) THD is the ratio of the rms sum of the first six harmonic components to the rms value of the fundamental signal and is expressed in decibels. POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 11 TLV5619 2.7 V TO 5.5 V 12-BIT PARALLEL DIGITAL-TO-ANALOG CONVERTER WITH POWER DOWN SLAS172C – DECEMBER 1997 – REVISED APRIL 2000 APPLICATION INFORMATION linearity, offset, and gain error using single end supplies When an amplifier is operated from a single supply, the voltage offset can still be either positive or negative. With a positive offset, the output voltage changes on the first code change. With a negative offset the output voltage may not change with the first code depending on the magnitude of the offset voltage. The output amplifier attempts to drive the output to a negative voltage. However, because the most negative supply rail is ground, the output cannot drive below ground and clamps the output at 0 V. The output voltage remains at zero until the input code value produces a sufficient positive output voltage to overcome the negative offset voltage, resulting in the transfer function shown in Figure 10. Output Voltage 0V DAC Code Negative Offset Figure 10. Effect of Negative Offset (Single Supply) This offset error, not the linearity error, produces this breakpoint. The transfer function would have followed the dotted line if the output buffer could drive below the ground rail. For a DAC, linearity is measured between zero input code (all inputs 0) and full scale code (all inputs 1) after offset and full scale are adjusted out or accounted for in some way. However, single supply operation does not allow for adjustment when the offset is negative due to the breakpoint in the transfer function. So the linearity is measured between full scale code and the lowest code that produces a positive output voltage. general function The TLV5619 is a 12-bit, single supply DAC, based on a resistor string architecture. It consists of a parallel interface, a power down control logic, a resistor string, and a rail-to-rail output buffer. The output voltage (full scale determined by reference) is given by: 2 REF CODE [V] 0x1000 Where REF is the reference voltage and CODE is the digital input value, range 0x000 to 0xFFF. A power on reset initially puts the internal latches to a defined state (all bits zero). 12 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 TLV5619 2.7 V TO 5.5 V 12-BIT PARALLEL DIGITAL-TO-ANALOG CONVERTER WITH POWER DOWN SLAS172C – DECEMBER 1997 – REVISED APRIL 2000 APPLICATION INFORMATION parallel interface The device latches data on the positive edge of WE. It must be enabled with CS low. LDAC low updates the DAC with the value in the holding latch. LDAC is an asynchronous input and can be held low, if a separate update is not necessary. However, to control the DAC using the load feature, LDAC can be driven low after the positive WE edge. TMS320C2XX, 5X A(0–15) TLV5619 IS Address Decoder CS LDAC WE WE D(0–11) D(0–15) Figure 11. Proposed Interface Between TLV5619 and TMS320C2XX, 5X DSPs TMS320C3X A(0–15) TLV5619 Address Decoder TCLK0 CS LDAC R/W WE IOSTROBE D(0–11) D(0–15) Figure 12. Proposed Interface Between TLV5619 and TMS320C3X DSPs POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 13 TLV5619 2.7 V TO 5.5 V 12-BIT PARALLEL DIGITAL-TO-ANALOG CONVERTER WITH POWER DOWN SLAS172C – DECEMBER 1997 – REVISED APRIL 2000 APPLICATION INFORMATION TLV5619 interfaced to TMS320C203 DSP hardware interface Figure 13 shows an example of the connection between the TLV5619 and the TMS320C203 DSP. The only other device that is needed in addition to the DSP and the DAC is the 74AC138 address decoding circuit . Using this configuration, the DAC address is 0x0084 within the I/O memory space of the TMS320C203. LDAC is held low so that the output voltage is updated with the rising WE edge. The power down mode is deactivated permanently by pulling PD to VDD. TMS320C203 74AC138 A2 A A3 A4 B Y1 C 5V G1 G2A A6 IS G2B TLV5619 12 D(0–11) D(0–11) VDD PD CS OUT WE WE REF191 Output RLOAD LDAC REFIN Figure 13. TLV5619 to TMS320C203 DSP Interface Connection software No setup procedure is needed to access the TLV5619. The output voltage can be set using one command: out data_addr, DAC_addr Where data_addr points to the address location (in this example 0x0060) holding the new output voltage data and DAC_addr is the I/O space address of the TLV5619 (in this example 0x0084). The following code shows, how to use the timer of the TMS320C203 as a time base to generate a voltage ramp with the TLV5619. A timer interrupt is generated every 205 µs. The corresponding interrupt service routine increments the output code (stored at 0x0060) for the DAC and writes the new code to the TLV5619. Only the 12 LSBs of the data in 0x0060 are used by the DAC, so that the resulting period of the saw waveform is: τ = 4096 × 205 E-6 s = 0.84 s 14 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 TLV5619 2.7 V TO 5.5 V 12-BIT PARALLEL DIGITAL-TO-ANALOG CONVERTER WITH POWER DOWN SLAS172C – DECEMBER 1997 – REVISED APRIL 2000 APPLICATION INFORMATION software listing ; File: ramp.asm ; Description: This program generates a ramp. ;––––––––––––– I/O and memory mapped regs ––––––––––– .include “regs.asm” TLV5619 .equ 0084h ;––––––––––––– vectors ––––––––––––––––––––––––––––––– .ps 0h b start b INT1 b INT23 b TIM_ISR ********************************************************************* * Main Program ********************************************************************* .ps 1000h .entry start: ldp #0 ; set data page to 0 ; disable interrupts setc INTM ; disable maskable interrupts splk #0ffffh, IFR splk #0004h, IMR ; set up the timer splk #0000h, 60h splk #0042h, 61h out 61h, PRD out 60h, TIM splk #0c2fh, 62h out 62h, TCR ; enable interrupts clrc INTM ; enable maskable interrupts ; loop forever! next idle ; wait for interrupt b next ; all else fails stop here done b done ; hang there ********************************************************************* * Interrupt Service Routines ********************************************************************* INT1: ret ; do nothing and return INT23: ret ; do nothing and return TIM_ISR: ; useful code add #1h ; increment accumulator sacl 60h out 60h, TLV5619 ; write to DAC clrc intm ; re-enable interrupts ret ; return from interrupt .end POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 15 TLV5619 2.7 V TO 5.5 V 12-BIT PARALLEL DIGITAL-TO-ANALOG CONVERTER WITH POWER DOWN SLAS172C – DECEMBER 1997 – REVISED APRIL 2000 MECHANICAL DATA DW (R-PDSO-G**) PLASTIC SMALL-OUTLINE PACKAGE 16 PIN SHOWN 0.050 (1,27) 0.020 (0,51) 0.014 (0,35) 16 0.010 (0,25) M 9 0.419 (10,65) 0.400 (10,15) 0.010 (0,25) NOM 0.299 (7,59) 0.293 (7,45) Gage Plane 0.010 (0,25) 1 8 0°– 8° A 0.050 (1,27) 0.016 (0,40) Seating Plane 0.104 (2,65) MAX 0.012 (0,30) 0.004 (0,10) 0.004 (0,10) PINS ** 16 20 24 A MAX 0.410 (10,41) 0.510 (12,95) 0.610 (15,49) A MIN 0.400 (10,16) 0.500 (12,70) 0.600 (15,24) DIM 4040000 / D 02/98 NOTES: A. B. C. D. 16 All linear dimensions are in inches (millimeters). This drawing is subject to change without notice. Body dimensions do not include mold flash or protrusion not to exceed 0.006 (0,15). Falls within JEDEC MS-013 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 TLV5619 2.7 V TO 5.5 V 12-BIT PARALLEL DIGITAL-TO-ANALOG CONVERTER WITH POWER DOWN SLAS172C – DECEMBER 1997 – REVISED APRIL 2000 MECHANICAL DATA PW (R-PDSO-G**) PLASTIC SMALL-OUTLINE PACKAGE 14 PIN SHOWN 0,30 0,19 0,65 14 0,10 M 8 0,15 NOM 4,50 4,30 6,60 6,20 Gage Plane 0,25 1 7 0°– 8° 0,75 0,50 A Seating Plane 1,20 MAX 0,10 0,05 MIN PINS ** 8 14 16 20 24 28 A MAX 3,10 5,10 5,10 6,60 7,90 9,80 A MIN 2,90 4,90 4,90 6,40 7,70 9,60 DIM 4040064 / E 08/96 NOTES: A. B. C. D. All linear dimensions are in millimeters. This drawing is subject to change without notice. Body dimensions do not include mold flash or protrusion not to exceed 0,15. Falls within JEDEC MO-153 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 17 IMPORTANT NOTICE Texas Instruments and its subsidiaries (TI) reserve the right to make changes to their products or to discontinue any product or service without notice, and advise customers to obtain the latest version of relevant information to verify, before placing orders, that information being relied on is current and complete. All products are sold subject to the terms and conditions of sale supplied at the time of order acknowledgment, including those pertaining to warranty, patent infringement, and limitation of liability. TI warrants performance of its semiconductor products to the specifications applicable at the time of sale in accordance with TI’s standard warranty. Testing and other quality control techniques are utilized to the extent TI deems necessary to support this warranty. Specific testing of all parameters of each device is not necessarily performed, except those mandated by government requirements. Customers are responsible for their applications using TI components. In order to minimize risks associated with the customer’s applications, adequate design and operating safeguards must be provided by the customer to minimize inherent or procedural hazards. TI assumes no liability for applications assistance or customer product design. TI does not warrant or represent that any license, either express or implied, is granted under any patent right, copyright, mask work right, or other intellectual property right of TI covering or relating to any combination, machine, or process in which such semiconductor products or services might be or are used. TI’s publication of information regarding any third party’s products or services does not constitute TI’s approval, warranty or endorsement thereof. Copyright 2000, Texas Instruments Incorporated