Brochure - SINAMICS V20

SINAMICS V20
The cost-effective, reliable and easy-to-use AC drive for basic applications
usa.siemens.com/sinamics-v20
Answers for industry.
SINAMICS V20
The perfect drive solution for basic applications
Power range
0.12–30kW
(1/6–40 hp)
Voltage range
1AC 200V ... 240V (+ / –10%)
3AC 380V ... 480V (+10 % / –15%)
Control modes
V/f V2/f FCC V/f multi-point
SINAMICS V20, the simple and versatile drive system for basic demands
Today, in an increasing number of applications, automation and drive solutions are
required to automate motion sequences.
The SINAMICS V20 from Siemens offers a simple drive solution for these types of
applications. It sets itself apart with its quick commissioning times, robustness,
ease-of-operation and cost-efficiency.
With five frame sizes, it covers a power range extending from 0.12 kW up to 30 kW
(1/6 hp up to 40 hp).
Minimize your costs
In today’s competitive environment, engineering, commissioning and operating
costs must be kept to a minimum. With SINAMICS V20, you have the precise
answer. To increase energy efficiency, the drive uses a control technique, which
automatically reduces motor flux when the motor is not operating at optimal
loading (ECO mode). The V20 displays actual energy consumption and has a
“hibernate” mode for periods when the drive is not being used — allowing energy
consumption to be drastically reduced.
Easy-to-install
n
Push-through and wall mounting — side-by-side possible for both
n
USS and Modbus RTU at terminals
n
Integrated braking chopper for 7.5–30 kW (10–40 hp)
Easy-to-use
n
Parameter loading without power supply
n
Integrated application and connection macros
n
Keep Running Mode for uninterrupted operation
n
Advanced cooling design and coated PCBs increase robustness
Easy to save money
2
n
ECO mode for V/f, V2/f
n
Hibernation mode
n
DC coupling
n
High overload and low overload mode for FSE
Typical applications and SINAMICS V20 benefits
Pumping, ventilating and compressing
n
High availability through automatic restart and flying restart after power failures
n
Broken belt detection by monitoring the load torque
n
Pump protection against cavitation
n
Hammer start and blockage clearing modes for clogged pumps
n
PID controller for process values (e.g. temperature, pressure, level, flow)
n
PID auto tuning to optimize controller parameters
n
Hibernation mode stops the motor when demand is low
n
n
Centrifugal pumps
n
Radial / axial fans
n
Compressors
n
Motor staging extends the flow range by adding two more fixed-speed
drives (cascade)
Frost and condensation protection preventsmoisture in motors under extreme
environmental conditions
Moving
n
n
Super torque start for conveyor belts with high breakaway torque
n
Dynamic behavior by using braking resistor or DC braking
n
Direct control of mechanical holding brake
n
Broken belt detection by monitoring the load torque
n
n
Belt conveyors
n
Roller conveyors
n
Chain conveyors
Soft, jerk-free acceleration reduces the stress on the gear units, bearings,
drums and rollers
Precise stopping with Quick Stop (switch-off positioning) independently
from the control cycle
Processing
n
n
n
Single drives in the process industry such as mills, mixers, kneaders, crushers,
agitators, centrifuges
Main drives in machines with mechanically coupled axes
such as ring spinning machines, braiding machines for textile, ropes and wire
Frost and condensation protection prevents moisture in motors under extreme
environmental conditions
n
Higher productivity with uninterrupted production due to Keep Running Mode
n
Exchange of regenerative energy via the DC link
n
Super torque start for machines with a high breakaway torque
3
SINAMICS V20 — Easy-to-install
Installation
SINAMICS V20 feature
Wall
mounting
Side-by-side
mounting
Push-through
mounting
V20
No space required
Cooling
Cooling
Compact design, side-by-side
mounting and flexible device
installation for both wall mounting
and push-through mounting.
Operation without additional
option modules possible.
Your benefits
n
n
n
n
Compact installation allows smaller
cabinets to be used
Push-through mounting allows the
cabinet to be cooled more easily
Can be run “out-of-the-box”
without other options
Basic operator actions at a built-in
BOP (Basic Operator Panel)
Communication
SINAMICS V20 feature
Siemens products
Other products
Standard
library
USS
The communication port is
available at the terminals.
The preset parameters of the
USS and Modbus RTU are defined
in the connection macro.
Your benefits
n
n
n
Modbus
Easy integration into
existing systems
Easy integration into micro
automation systems
Easier commissioning
through standard libraries
and connection macros
SINAMICS V20
Braking module
SINAMICS V20 feature
Your benefits
SINAMICS V20
The dynamic energy is dissipated
as heat in a braking resistor with an
adjustable duty cycle of between
5–100%.
Braking module
Motor
f
t
4
Resistor
n
n
Possible to use dynamic braking
to increase braking performance
Drives ≥ 7.5 kW have an integrated
braking module. In this case,
the braking resistor can be
directly connected.
SINAMICS V20 — Easy-to-use
Parameter cloning
SINAMICS V20 feature
Parameter loading
Commissioning
Parameter settings can be easily
transferred from one unit to another
using the parameter loader — even
without a power supply.
Your benefits
n
Less technical support required
n
Short commissioning time
n
The product is delivered to the
customer already preset
Copy configuration
Macro approach
SINAMICS V20 feature
Connection and application
macros to simplify I/O configuration
and make the appropriate settings.
Your benefits
n
n
n
Fan
Macro
SINAMICS
V20
n
Shorter training and
commissioning time
Integrated and optimized
application setting
Simple connection and application
macros can be selected instead of
configuring long complic­ated
parameter lists
Errors caused by wrong parameter
settings can be avoided
Keep Running Mode
SINAMICS V20 feature
The function provides higher
productivity in production by
automatic adaptation in the case
of unstable line supplies.
SINAMICS V20
Your benefits
n
n
Motor
n
Stable operation under difficult
line supply conditions
Higher productivity through
prevention of interruptions of
the production line
Adaptation to application-relevant
reactions through flexible definition
in case of fault / alarm
Robustness
SINAMICS V20 feature
Better cooling design and coated PCB
increase robustness of the drive in
difficult application environments.
Your benefits
n
n
SINAMICS V20
n
Motor
Operation possible when the line
supply voltage fluctuates
Reliable operation for line voltages:
1AC 200V … 240V (–10% / +10%)
3AC 380V … 480V (–15% / +10%)
Operation up to an ambient
temperature of 60° C
5
SINAMICS V20 — Easy to save money
Energy reduction during operation
¹⁾
SINAMICS V20 feature
Integrated ECO mode for V/f
and V2/f automatically adapts
the flux to save energy. The
energy consumption can be
shown in kWh, CO2 or even in
the local currency.
60%
UP TO
ENERGY-SAVINGS POTENTIAL
Your benefits
n
n
n
Energy saving during low dynamic
load cycles
If the setpoint changes, the ECO
mode is automatically deactivated
Tells end-users the actual energy
that has been saved
Energy reduction during operation — DC coupling
Energy consumption
Energy generation
SINAMICS V20 feature
Applications that use SINAMICS
V20 drives with the same power
rating can share a common DC bus
to reuse the regenerative energy.
Your benefits
n
n
Energy
n
SINAMICS V20
SINAMICS V20
Generate and save energy
in applications that use
coupled motors
Pairs of identical drives can
optimally share resources
Reduce the need for dynamic braking
and external components
Energy reduction during standby — hibernation mode
SINAMICS V20 feature
f
Save
energy
threshold
t
Inverter and motor only operate
when the plant or machine
re-quires them to. Hibernation
mode will be automatically
activated when the frequency
demand or the feedback
from a sensor drops below
a specific threshold.
Your benefits
n
Smart hibernation saves energy
n
Extended lifetime of motor
n
Reduced pump wear at low speed
n
Less time to program PLC code for
pump / fan applications (PLC)
Cost-savings at low overload application
High Overload
Low Overload
SINAMICS V20 feature
SINAMICS V20 FSE (22 kW and
30 kW) integrated two different
load cycles.
n
n
Low Overload (LO):
110% IL ²) for 60 s
(cycle time: 300 s)
High Overload (HO):
150% IH ³) for 60 s
(cycle time: 300 s)
¹⁾ Application and machine-type dependent
²⁾ The output current IL is based upon the duty cycle for low overload (LO).
³⁾ The output current IH is based upon the duty cycle for high overload (HO).
6
Your benefits
n
n
With low overload cycle, the drive
can reach a higher output current and
power. A smaller drive can be used.
Optimally designed for a variety
of applications:
Low Overload for applications
with a low dynamic response
(continuous duty)
High Overload for applications with
a high dynamic response (cyclic duty)
n
n
Combining SINAMICS V20 drives with SIMATIC PLC
Easy automation system
SIMATIC Panel
SIMATIC PLC
Ethernet / PROFINET
SINAMICS V20
USS
MODBUS RTU
Saving time and minimizing errors
n
Easy system configuration with pre-defined macros in the drive and pre-built Totally
Integrated Automation Portal function blocks for quick connection to SIMATIC S7-1200**
n
One cable to connect SINAMICS V20 with USS or MODBUS RTU
n
Integrated communication interface
** A
pplication example with function blocks can be downloaded from Siemens Industry
Online Support: http://support.automation.siemens.com/WW/view/en/63696870
7
SINAMICS V20 — Overload capability characteristics
M= n²
P ~ n³
M= torque
n = speed
P = power
Low Overload (LO) is generally used for applications demanding a low
level of dynamic performance (continuous duty), square-law torque
characteristic with low breakaway torque and low speed precision.
For example: centrifugal pumps, radial / axial fans, reciprocating
blowers, radial compressors, vacuum pumps, agitators, etc.
Low overload (LO) capability
110% IL ¹) for 60 s within a cycle time of 300 s
¹) The output current IL is based on the duty cycle for low overload (LO).
M= constant
P ~ n
M= torque
n = speed
P = power
High Overload (HO) is generally used for applications demanding a
higher dynamic performance (cyclic duty), as well as constant torque
characteristics with a high breakaway torque.
For example: conveyor belts, geared pumps, eccentric worm pumps,
mills, mixers, crushers, vertical conveying equipment, centrifuges, etc.
High overload (HO) capability
150% IH ²) for 60 s within a cycle time of 300 s
2)
The output current IH is based on the duty cycle for high overload (HO).
SINAMICS V20 — best-in-class service and support
At home or across the globe
n
n
n
8
Global hotline support
Comprehensive service network of factory-trained
repair specialists
Online Support
The comprehensive online information platform supports
you in all aspects of our service and support at any time
and from any location in the world.
Multiple language web-based support and FAQs
siemens.com/automation/service&support
Country
Hotline
Technical support
USA
+1 423 262 5710 / +1 800 333 7421
Germany
+49 911 895 7222
India
+91 22 2760 0150
China
+86 400 810 4288
Expert advice on technical questions with a wide range
of demand-optimized services for all our products
and systems.
Additional service contact information:
siemens.com/automation/support-request
SINAMICS V20 — Full range of options, everything you need…
Fuse
Circuit breaker
V20 BOP
(Basic Operator Panel)
Line
reactor
Braking resistor, small
(FSA, FSB, FSC)
Braking resistor, large
(FSD and FSE)
Line
filter
BOP
Cable
BOP Interface
(Basic Operator Panel)
Braking module
(FSA, FSB, FSC)
SINAMICS Memory
Card (SD)
Shield connection kit
Output reactor
Parameter loader
SINAMICS V20 — Options
V20 BOP
Same functionality as the integrated Basic Operator Panel
(BOP), but can be used for remote mounting. The value
and setpoint are changed by rotating the wheel.
BOP interface
n Connection between inverter and BOP
BOP cable
3 m cable with connectors
Parameter loader
Up to 100 parameter sets with parameter settings can
be written from the memory card to the inverter or saved
from the inverter to the memory card without connecting
the inverter to the line supply.
SINAMICS Memory Card (SD)
n 512 MB
Line filter
n Improved EMC performance
n Longer motor cable for FSA
Line reactor
n Reduces the harmonic current
n Improves the power factor
n Recommended if input current (RMS value) is higher
than the rated current of the drive.
Braking module
n Shortens the deceleration ramp time
n Suitable for 1AC 230V and 3AC 400V
n Adjustable duty cycle from 5–100%
n FSD and FSE already have an integrated braking unit
Braking resistor
n Dissipates regenerative energy as heat
n 5% duty cycle as default setting
Output reactor
Longer motor cable:
n 3AC 400V shielded and unshielded cable: 150 m
n 1AC 230V shielded and unshielded cable: 200 m
Shield connection kit
n Shield connection
n Strain relief
Fuse
Recommended fuse corresponding to the EC/UL standard
Circuit breaker
Recommended circuit breaker corresponding to the
EC/UL standard
9
Technical information
Power and control
Voltage
1AC 230V: 1AC 200V ... 240V (–10% ... +10%)
3AC 400V: 3AC 380V ... 480V (–15% ... +10%)
Maximum output voltage
100% of input voltage
Supply frequency
50 / 60 Hz
Line supply type
TN, TT, TT earthed line, IT ¹)
Power range
1AC 230V 0.12 … 3.0 kW (1/6 … 4 hp)
3AC 400V 0.37 … 30 kW (1/2 … 40 hp)
cos φ / Power factor
≥ 0.95 / 0.72
Overload capability
up to 15 kW:
High Overload (HO): 150% IH for 60 s within a cycle time of 300 s
from 18.5 kW:
Low Overload (LO): 110% IL for 60 s within a cycle time of 300 s
High Overload (HO): 150% IH for 60 s within a cycle time of 300 s
Output frequency
0 ... 550 Hz resolution: 0.01 Hz
Efficiency factor
98%
Control modes
Voltage / frequency control mode:
linear V/f, square law V/f, multi-point V/f
Flux current control mode: FCC
Standards
Standards
CE, cULus, C-tick, KC
EMC standards, radiated
emissions and
disturbance voltage
(conducted emissions)
EN61800-3 category C2, 1st environment (domestic premises):
n
n
1AC 230V with integrated line filter, shielded cables ≤ 25 m (FSA ≤ 10 m ²))
3AC 400V without integrated line filter with external line filter, shielded cables
FSA up to FSD ≤ 25 m, FSE ≤ 50 m
EN61800-3 category C3, 2nd environment (industrial premises):
n
3AC 400V with integrated line filter, shielded cables FSA ≤ 10 m, FSB up to
FSD ≤ 25 m, FSE ≤ 50 m
Features
Energy savings
Ease-of-use
Application
Protection
n
ECO mode
n
Hibernation mode
n
Energy consumption monitoring
n
n
Connection and application macro
n
Drive status at fault
Parameter cloning
n
Automatic restart
n
Keep Running Mode
n
Flying start
n
USS / Modbus RTU communication
n
DC-link voltage control
n
Customized default value
n
Imax control
n
List of modified parameters
n
PID controller
n
Flexible boost control
n
BICO function
n
Wobble function
n
Hammer start
n
Slip compensation
n
Super torque mode
n
Dual ramp
n
Blockage clearing mode
n
Adjustable PWM modulation
n
Motor staging
n
Frost protection
n
Kinetic buffering
n
Condensation protection
n
Load failure detection
n
Cavitation protection
¹) Only 3AC 400V unfiltered devices can be operated at IT network.
²) To achieve 25 m shielded motor cable length also with FSA, unfiltered devices with external filter have to be used.
10
Signal inputs and outputs
Analog inputs
AI1: bipolar current / voltage mode
AI2: unipolar current / voltage mode
Can be used as digital inputs
Analog outputs
A01: 0 … 20 mA
Digital inputs
DI1–DI4, optically isolated PNP/NPN selectable by terminal
Digital outputs
DO1: transistor output
DO2: relay output
n
n
250V AC 0.5 A with resistive load
30V DC 0.5 A with resistive load
Connection diagram
FSA up to FSC
FSD, FSE
400 V
Main circuit
M
230 V
Control circuit
External 24V supply
Digital inputs
Digital outputs
Internal 24V supply
Transistor
output
Relay
output
Analog output
Analog inputs
≥ 4.7 Ω
RS-485
Expansion port
Mounting and environment
Degree of protection
IP20
Mounting
Wall mounting, side-by-side mounting, push-through mounting for FSB, FSC, FSD and FSE
Cooling
n
n
FSA up to 0.75 kW: convection cooling
FSA up to FSE: power electronics cooled using heat sinks with external fan
Ambient temperature
In operation
n –10 … 60° C (14 … 140° F)
n 40 … 60° C (104 … 140° F) with derating
In Storage
n –40 ... 70° C (–40 ... 158° F)
Relative humidity
95% (non-condensing)
Altitude
n
Up to 4000 m above sea level
n
1000 ... 4000 m: output current derating
n
2000 ... 4000 m: supply voltage derating
n
Unshielded cable: 50 m for FSA up to FSD, 100 m for FSE
n
Shielded cable: 25 m for FSA up to FSD, 50 m for FSE
n
Longer motor cables possible with output reactor (see options)
Motor cable length
Dynamic braking
Option module for FSA, FSB and FSC; integrated for FSD and FSE
11
Dimensions
SINAMICS V20 drive
W2
D
Width (mm)
H2
H3
H1
W1
Depth (mm)
Weight (kg)
H1
Height (mm)
H2
H3
D
WT approx.
90
–
140
150
145.5
1
90
166
140
150
145.5
1.05
127
140
160
135
–
164.5
1.8
Frame size
W1
W2
FSA without fan
79
FSA
79
FSB
FSC
170
184
182
140
–
169
2.6
FSD
223
240
206.5
166
–
172.5
4.3
FSE
228
245
264.5
206
–
209
6.6
V20 Basic Operator Panel (BOP)
31.5
Basic Operator Panel (BOP) interface
66.9
91
28.7
21.9
89.9
3.7
17
36.6
81.7
57
97
35
3.
5
drill pattern
Parameter loader
35
89.9
57
OPEN
28.2
12
BOP
1AC 230V options
Braking resistors
Prated (HO) kW
1AC 230 V
0.12
FS
W
A
72
230 43.5
1.1
B
149
239
2.2
C
185
285
0.25
0.37
0.55
0.75
1.5
3
H
D
150
WT
1
Line reactors
W
H
75.5 200
Output reactors
Braking module
Line filter class B
D
WT
W
H
D
WT
W
H
D
WT
W
50
1.4
75
200
50
1.3
90
150
88
0.71
73
200 43.5 0.5
80
4.1
149
213 50.5
1.6
150
213
2.2
150
213
3.8
185
245
5.1
185
245
H
6.6
D
WT
1
–
3AC 400V options
Braking resistors
Prated (LO) kW
3AC 400 V
0.37
0.55
FS
W
H
A
105
295
105
D
WT
Line reactors
W
Output reactors
Braking module
Line filter class B
H
D
WT
W
H
D
WT
W
H
D
WT
W
H
D
WT
100 1.48 125
120
71
1.1
207
175
73
3.4
90
150
80
0.71
73
202
65
1.75
345
100 1.80 125
140
71
2.1
207
180
73
3.9
175
345
100 2.73 125
145
91
2.95 247
215
100 10.1
100
297
85
4
250
490
140 6.20
140
359
95
7.3
270
515
175
260
180
600
7.3
0.75
1.1
1.5
2.2
3
B
5.5
C
4
7.5
11
15
22
D
E
7.4
190
300
220
620
91
85
7.8
257
235
9.5
250
280
115 11.2
integrated
250 11.3
30
320 800 95
17
FS = frame size, WT = weight in kg, W = width in mm, H = height in mm, D = depth in mm
335
200
175
7.5
Simple entry using the DT Configurator
The DT Configurator supports you with:
n
Selecting the drive based upon the application
n
The subsequent ordering process
DT Configurator supplies you with:
n
A drive that is tailored to your requirements
n
2D / 3D models
n
Operating instructions
n
Data sheets
You can directly order the selected components through
the Industry Mall — the Siemens e-commerce website —
and without having to duplicate entries. In order to avoid
making ordering mistakes, the order number is checked to
ensure that it is correct.
SINAMICS SELECTOR app —
find part numbers quickly and easily
Scan this QR code to download our
SINAMICS SELECTOR app free-of-charge
siemens.com/dt-configurator
13
Ordering information
1AC 230V
Rated data
Prated (HO)
kW
IH
hp
Part number
A
Fans
0.12
1/6
0.9
6SL3210-5BB11-2
V0
–
0.25
1/3
1.7
6SL3210-5BB12-5
V0
–
0.37
1/2
2.3
6SL3210-5BB13-7
V0
–
0.55
3/4
3.2
6SL3210-5BB15-5
V0
–
0.75
3/4
3.9
6SL3210-5BB17-5
V0
–
0.75
1
4.2
6SL3210-5BB18-0
V0
1
1.1
1–1/2
6
6SL3210-5BB21-1
V0
1
1.5
2
7.8
6SL3210-5BB21-5
V0
1
2.2
3
11
6SL3210-5BB22-2
V0
1
3
4
13.6
6SL3210-5BB23-0
V0
1
Frame
size
FSA
FSB
FSC
EMC Standards
With integrated line filter category C26)
A
Without integrated filter
U
1AC 230V options
FS
A
Prated
(HO)
kW
Shield
Braking resistor Line reactor Output reactor connection
kit
6SE6400-...
6SE6400-...
6SE6400-...
6SL3266-...
0.12
Corresponding to the IEC standard
Line filter
class B³)
6SE6400-...
Part
number
3RV2011-1DA10
3NA3803
3NA3803
3RV2011-1FA10
10
3NA3803
3RV2011-1HA10
0.55
10
3NA3803
3RV2011-1JA10
0.75
16
3NA3805
3RV2011-1KA10
20
3NA3807
3RV2021-4BA10
32
3NA3812
3RV2021-4CA10
35
3NA3814
3RV2021-4EA10
50
3NA3820
3RV1031-4FA10
3CC00-4AB3
3TC00-4AD3
1AA00-0VA0
2FL01-0AB0
1.1
3CC01-0AB3
4BC11-2BA0
3CC02-6BB3
3TC01-0BD3
1AB00-0VA0
–
1.5
2.2
3
1AC00-0VA0
4BC12-5CA0
3CC03-5CB3
3TC03-2CD3
Accessories
Spare parts
Name
Part number
Replacement fan
Parameter loader
6SL3255-0VE00-0UA0
Frame size
Part number
BOP (Basic Operator Panel) interface
6SL3255-0VA00-2AA0
FSA
6SL3200-0UF01-0AA0
FSB
6SL3200-0UF02-0AA0
FSC
6SL3200-0UF03-0AA0
Braking module
1AC 230V: 8A
n 3AC 400V: 7A
6SL3201-2AD20-8VA0
n
14
Part
number
10
0.37
C
Current
in A
Circuit breaker⁴)
10
4BC05-0AA0
0.25
B
Standard fuse⁴)
V20 BOP (Basic Operator Panel)
6SL3255-0VA00-4BA0
BOP cable 3 m incl. 4 mounting screws
6SL3256-0VP00-0VA0
SINAMICS Memory Card (SD) 512 MB
6SL3054-4AG00-2AA0
RS485 Terminators (50 pieces)
6SL3255-0VC00-0HA0
SINAMICS V20 training case
6AG1067-2AA00-0AB6
DIN Rail mounting kit
FSA: 6SL3261-1BA00-0AA0⁵)
FSB: 6SL3261-1BB00-0AA0
FSD
6SL3200-0UF04-0AA0
FSE
6SL3200-0UF05-0AA0
3AC 400V
Rated data
Prated (LO)
kW
IL 400 V¹)
IL 480 V
A
A
hp
Prated (HO)
kW
hp
IH 400 V²)
IH 480 V
A
A
Part number
Fans
Frame
size
FSA
0.37
1/2
1.3
1.3
0.37
1/2
1.3
1.3
6SL3210-5BE13-7
V0
–
0.55
3/4
1.7
1.7
0.55
3/4
1.7
1.7
6SL3210-5BE15-5
V0
–
0.75
1
2.2
2.2
0.75
1
2.2
2.2
6SL3210-5BE17-5
V0
–
1.1
1–1/2
3.1
3.1
1.1
1–1/2
3.1
3.1
6SL3210-5BE21-1
V0
1
1.5
2
4.1
4.1
1.5
2
4.1
4.1
6SL3210-5BE21-5
V0
1
2.2
3
5.6
4.8
2.2
3
5.6
4.8
6SL3210-5BE22-2
V0
1
3
4
7.3
7.3
3
4
7.3
7.3
6SL3210-5BE23-0
V0
1
4
5
8.8
8.24
4
5
8.8
8.24
6SL3210-5BE24-0
V0
1
5.5
7–1/2
12.5
11
5.5
7–1/2
12.5
11
6SL3210-5BE25-5
V0
1
FSC
7.5
10
16.5
16.5
7.5
10
16.5
16.5
6SL3210-5BE27-5
V0
2
FSD
11
15
25
21
11
15
25
21
6SL3210-5BE31-1
V0
2
15
20
31
31
15
20
31
31
6SL3210-5BE31-5
V0
2
22
30
45
40
18.5
25
38
34
6SL3210-5BE31-8
V0
2
30
40
60
52
22
30
45
40
6SL3210-5BE32-2
V0
2
FSB
FSE
EMC Standards
With integrated line filter category C3 7)
C
Without integrated filter
U
3AC 400V options
FS
FSA
FSB
Prated
(LO)
kW
Prated
(HO)
kW
0.37
0.37
0.55
0.55
0.75
Braking resistor Line reactor
6SL3201-...
6SL3203-...
Shield
connection
kit
6SL3266-...
Line filter
class B3)
6SL3203-...
0AE16-1CA0
1AA00-0VA0
0BE17-7BA0
Standard fuse⁴)
Circuit breaker⁴)
Current
in A
Part
number
6
3NA3801
3RV2011-1CA10
6
3NA3801
3RV2011-1DA10
0.75
6
3NA3801
3RV2011-1EA10
1.1
1.1
6
3NA3801
3RV2011-1FA10
1.5
1.5
10
3NA3803
3RV2011-1HA10
2.2
2.2
16
3NA3805
3RV2011-1JA10
3
3
4
4
FSC
5.5
5.5
FSD
7.5
7.5
11
11
15
15
0BE14-3AA0
22
18.5
30
22
0CE13-2AA0
0CE21-0AA0
0BE21-0AA0
0AE18-8CA0
0BE21-8AA0
0CE21-8AA0
0AE23-8CA0
0BE23-8AA0
4BD21-2DA0
16
3NA3805
3RV2011-1KA10
3NA3807
3RV2021-4AA10
1AC00-0VA0
32
3NA3812
3RV2021-4BA10
1AD00-0VA0
–
–
3VL1103-1KM30-0AA0
–
–
3VL1104-1KM30-0AA0
–
–
3VL1105-1KM30-0AA0
63
3NA3022
3VL1108-1KM30-0AA0
80
3NA3024
3VL1108-1KM30-0AA0
0BE21-8BA0
0BE23-8BA0
0CE23-8AA0
6SE6400-…
6SE6400-…
6SL3266-…
3CC05-2DD0
3TC05-4DD0
1AE00-0VA0
3CC08-3ED0
Part
number
20
1AB00-0VA0
0AE21-8CA0
6SE6400-…
FSE
Corresponding to the IEC standard
Output
reactor
6SL3202-...
6SL3203-…
0BE23-8BA0
0BE27-5BA0
¹⁾ The output current IL is based on the duty cycle for low overload (LO).
²⁾ The output current IH is based on the duty cycle for high overload (HO).
³⁾ See specification of EMC standards, page 10
⁴⁾ Additional information about the listed fuses and circuit breakers can be found in Catalogs LV 10, IC 10 and IC 10 AO
siemens.com/drives/infocenter
⁵⁾ Installation of FSA with fan — please refer to SINAMICS V20 manual.
6
⁾ EN61800-3 Catagory C2, 1st environment (residential domestic)
7
⁾ EN61800-3 Catagory C3, 2nd environment (industry)
15
There’s more to it
usa.siemens.com/sinamics
Everything about our
drive family can be
found online.
SINAMICS —
one family, one source,
all applications
Siemens Industry, Inc.
5300 Triangle Parkway, Suite 100
Norcross, GA 30092
1-800-879-8079
[email protected]
usa.siemens.com/motioncontrol
Order No. DRBR-V2001-0415
Printed in USA
© 2015 Siemens Industry, Inc.
This brochure contains only general descriptions or
performance features, which do not always apply in the
manner described in concrete application situations or
may change as the products undergo further development.
Performance features are valid only if they are formally
agreed upon when the contract is closed.
Siemens is a registered trademark of Siemens AG.
Product names mentioned may be trademarks or registered
trademarks of their respective companies. Specifications
are subject to change without notice.