SIRIUS modular system Switching, protecting, starting and monitoring with the highly flexible modular system siemens.com/sirius 2 Everything for the control cabinet: the SIRIUS modular system. Contents The components of the SIRIUS modular system Combination of switching devices and protective devices Convenient means of power supply and distribution Control console Press shop Final assembly Body shop Power distribution Powertrain/ assembly Paint shop Processing, fitting, transporting. These and similar functions run on many automated production lines. With the extensive range of the SIRIUS modular system, you will find everything you need for switching, protecting, starting and monitoring motors. Everything. Really easy. With SIRIUS. 4 8 9 Electromechanical switching devices for fuseless assembly of load feeders up to 7.5 kW Size S00 selection and ordering data: 10 Motor starter protector, contactor with overload relay Motor starter protector, contactor with current monitoring relay 10 10 Motor starter protector, soft starter with current monitoring relay Motor starter protector, solid-state switching device with current monitoring relay 13 13 Electromechanical switching devices for fuseless assembly of load feeders up to 18.5 kW Size S0 selection and ordering data: 16 Motor starter protector, contactor, overload relay Motor starter protector, contactor with current monitoring relay 17 17 Motor starter protector, soft starter with current monitoring relay 18 Assembly of direct-on-line starters and reversing starters 30/37.5 kW Size S2 selection and ordering data: 20 Motor starter protector, contactor, overload relay Motor starter protector, contactor with current monitoring relay 20 20 Assembly of direct-on-line starters and reversing starters up to 45 kW Size S3 selection and ordering data 24 Size S6, S10 and S12 Selection and ordering data 26 Fuseless load feeders Selection and ordering data: Direct-on-line starters (fully pre-assembled load feeders, compact starters) Reversing starters (fully pre-assembled load feeders, compact starters) 29 Communication connection (IO-Link/AS-Interface master, contactors, function modules for mounting on 3RT2 contactors and for connecting to the automation level, compact starters) 31 Infeed systems For compact starters, load feeders, 3-phase busbar, 8US busbar adapter 34 30 Accessories Selection and ordering data: Motor starter protectors Contactors Overload relays, current monitoring relays 37 39 44 Planning Efficiency 46 Everything. Systematically. SIRIUS modular system. Building control cabinets must be fast, simple, flexible and space-saving. How can all this be achieved? With the unique SIRIUS modular system that offers everything you will need for switching, protecting, and starting motors and systems. In other words, it provides a modular range of standard components up to 250 kW/ 400 V in only seven sizes, which are perfectly matched to one another, can be combined really easily, and largely use the same accessories. That’s how easy industrial controls can be! SENTRON 3VL Continuous further development and regular innovations ensure that our customers are optimally equipped with SIRIUS and benefit from efficient solutions – now and in the future. All the components that make up the SIRIUS modular system are characterized by a space-saving design and a high degree of flexibility. Configuring, installing, wiring and maintenance are extremely easy and time-saving to perform. So no matter whether you want to configure load feeders with motor starter protectors, overload relays, contactors/solid-state contactors or soft starters, SIRIUS has just the product you will need for any application. Thanks to the latest innovations to the modular system in sizes S00, S0 and S2 up to 80 A, today’s SIRIUS modular system shows even more functional diversity: Motor starter protectors In addition to the basic components, the innovated SIRIUS modular system offers new, never-before-seen highlights: • Feeder assemblies that can be plugged in completely without tools thanks to the consistent use of spring-loaded connections in sizes S00 and S0 Contactors Overload relays • 2- and 3-phase 3RR2 monitoring relays for current monitoring for direct mounting on contactors • 3RA27 and 3RA28 function modules feature snap-on connection to contactors enabling the easiest possible assembly of direct-on-line starters, reversing starters, and star-delta (wye-delta) starting, and connection to the controller using less wiring via AS-Interface or IO-Link • 3RB24 overload relay with communication capability, current value transmission, and control of the contactors via IO-Link S00 S0 S2 S3 S6 S10 S12 Soft starters • A highlight of the SIRIUS devices is their IE3 suitability, so that they are optimally equipped for conversion to the new IE3 generation of motors 3 4 At a glance. The components of the SIRIUS modular system offer a host of benefits. With its wide range of components, the SIRIUS modular system features the most diverse functions for use in the control cabinet, and offers a host of benefits in assembly and handling, in application monitoring, and also in controller interfacing, or when planning and configuring. Assembly and handling: Applications at a glance: Planning and configuration: Error prevention and reduced wiring effort – with maximum flexibility Increased operational reliability and system availability Simplified system planning and documentation • Maintenance: extremely durable, low maintenance, and reliable • Application monitoring: integrated extremely flexibly into the feeder – thanks to monitoring relays for current monitoring • IE3-ready: With the SIRIUS modular system, we also offer you our familiar reliability when converting to IE3 motors • Configuration: easy and fast thanks to extensive CAx data provision • Service: short delivery times even for spare parts thanks to global logistics network • Environment: environmentally friendly production and materials, recyclable • Design: clear, ergonomic design (winner of the iF Product Design Award) • Configurator: for the simplest possible selection of products including accessories • Global use: thanks to comprehensive approvals • Load feeders: easy to implement up to 250 kW/400 V from standard devices • Modular design: everything fits together and can be combined • Variants and sizes: economical and flexible thanks to 7 compact sizes • Accessories: low variance with uniform accessories • Configuration: fast commissioning, short setting-up times, and simple wiring • Mounting: permanently secure mounting, with screw terminals or simply by plugging in • Spring-loaded connection system: quick and secure connection, vibration-proof, and maintenance-free • Reduced wiring: significant reductions in cable connections thanks to plug-in design and IO-Link or AS-Interface Connection to the automation level: Optimal integration into the automation environment • Communication: standardized connection to AS-Interface, IO-Link and PROFIBUS DP possible Switching. Protecting. Starting. Monitoring. The components of the SIRIUS modular system. Much more than ON/OFF: SIRIUS 3RV motor starter protectors The SIRIUS 3RV motor starter protectors are compact, current-limiting motor starter protectors. They ensure secure disconnection in case of a short circuit, and they protect consumers and the system against overload. They are also suited to normal switching duties for loads with a low switching frequency, and for safely isolating the system from the power supply during maintenance work or modifications. For applications over 100 A, SENTRON 3VA and 3VL circuit breakers are suitable. Rugged and reliable: SIRIUS 3RT contactors Thanks to their extreme ruggedness and outstanding contact reliability, our contactors switch supremely and reliably. In addition, they enable compact control cabinets with high packing density. With integrated ranges of accessories for sizes S00, S0 and S2, as well as S3 to S12, individual function expansions can be implemented with no great effort. In sizes S00, S0 and S2, the contactors even have the auxiliary switches integrated into the enclosure. Tripping when things get serious: SIRIUS 3RU and 3RB overload relays The overload relays of the SIRIUS family are available in thermal and electronic versions, and they are responsible for the inversetime-delayed overload protection in the main circuit. The SIRIUS 3RB electronic overload relays ensure seamless protection for motors and systems from 0.1 A to 630 A. This current range can be covered with a minimum number of variants thanks to the large setting range. At the same time, power losses are reduced by up to 98% compared to the thermal versions. The devices thus effectively support the global trend for saving energy. Simplest possible application monitoring: SIRIUS 3RR2 current monitoring relays The SIRIUS current monitoring relays monitor not so much the motor as the entire plant or driven process for overcurrent and undercurrent, wire break, or phase failure. Thus, load shedding or overload of an application, for example, is detected quickly and reported early. The 3RR2 monitoring relay for current monitoring is integrated directly into the load feeder in sizes S00, S0 and S2. Just attach it to the contactor, and click ‘n’ go. Soft starting: SIRIUS 3RW soft starters SIRIUS 3RW soft starters offer a complete range that covers all standard and high-feature applications of motor starting. Thus the benefits of soft starting can be reaped in the most diverse applications up to 55 kW (at 400 V) for simple and economical implementation of optimum machine concepts. Economical and space-saving soft starting can be implemented up to 55 kW (at 400 V) with the compact 3RW30 with two-phase control. The 3RW40 also offers soft run-down as well as integrated intrinsic device protection functions and motor protection functions. An additional overload relay can therefore be dispensed with. SIRIUS soft starters are available for line voltages up to 600 V – optionally also with thermistor motor protection evaluation. 5 6 Switching. Protecting. Starting. Monitoring. The components of the SIRIUS modular system. SIRIUS contactor with screw terminals Master the highest switching frequencies with confidence: SIRIUS 3RF solid-state contactors SIRIUS solid-state contactors (size S0) for switching motors impress with their almost limitless service life – even under harsh conditions and at high switching frequencies. The three-phase solid-state contactors switch motors completely silently up to 7.5 kW. A special reversing contactor version enables changing of the direction of rotation of motors up to 3 kW. The compact devices in widths of 45 or 90 mm can be combined with our motor starter protectors, current monitoring relays, or electronic overload relays. For fast and simple assembly of fuseless and fused motor feeders. Compact switching and protecting with a high number of additional functions: SIRIUS 3RA6 compact starters Equipped with the functions of a motor starter protector, a contactor, and an electronic overload relay, the compact starter as a direct-on-line or reversing starter up to 32 A offers maximum reliability with minimum variance. Safe shutdown at end of service life provides an additional advantage with regard to system availability. Reduced wiring in the main circuit thanks to the ingeniously simple infeed system including PE connection, and in the control circuit thanks to the optional AS-Interface or integrated IO-Link interface represent the fastest possible assembly of entire feeder groups. Thanks to incorporation into the concept of Totally Integrated Automation and pre-defined faceplates for visualization, informative device diagnostics are available without the otherwise necessary configuring effort. SIRIUS contactor with spring-loaded terminals SIRIUS contactor with ring cable lug connection Faster wiring thanks to integrated spring-loaded terminals Maximum flexibility when it comes to connections The entire S00/S0 range in the main and control circuit is available for the first time with spring-loaded terminals. This accelerates device connection, and offers maximum safety in operation. The extremely simple wiring guarantees fast installation. A further advantage: The gas-tight terminal connection is resistant to shaking and vibration. In addition, you benefit from maximum contact reliability – even under the harshest of conditions. No need to re-tighten the connection terminals (often the usual practice). A special advantage: The link modules for direct-on-line, reversing, and star-delta (wye-delta) starting are also available with spring-loaded terminals. With this, you can mount entire feeders completely without tools. In size S2, spring-loaded terminals in the auxiliary circuit are optionally available. All the components of the SIRIUS modular system are, of course, also available with screw terminals – largely even with ring cable lug connections – for special requirements such as mechanical engineering in the semiconductor industry. Switching. Protecting. Starting. Monitoring. The components of the SIRIUS modular system. Straight to the point: the 3RA21 direct-on-line starter Ready for immediate use: pre-wired SIRIUS load feeders Load feeders start loads with a combination of protection and switching functions. To reduce time and costs, and above all to minimize standstill times, we offer you a wide range of pre-wired starter solutions: Phases swapped: the 3RA22 reversing starter • Direct-on-line starters up to 30 kW – the right starter combination for all motors – both for standard rail mounting as well as with 60 mm busbar adapter. • Reversing contactor assemblies up to 37 kW – the appropriate combination for reversing duty – both for standard rail mounting as well as with 60 mm busbar adapter. • Contactor assemblies for star-delta starting up to 75 kW – the solution for starting in stages for reducing start-up current peaks of motors. • Soft starters – when soft starting and stopping are required (in the case of the 3RW40 even with integral overload protection). Two stages – one start: the 3RA24 contactor assembly for star-delta start An almost unlimited number of further tested combinations can be assembled easily from the individual components. The following manuals help you to make your selection, and they can be found in the Industry Online Support Portal at http://support.automation.siemens.com. SIRIUS Innovations: Configuration Manual “Configuring SIRIUS Innovations – Selection Data for Fuseless and Fused Load Feeders” SIRIUS: Configuration Manual “Configuring SIRIUS – Selection Data for Load Feeders in Fuseless Design” Configuration instructions for IE3 motors: Configuration manual for SIRIUS switching devices with IE3 motors 7 Combination of switching devices and protective devices Electromechanical switching devices Contactor and overload relay with fuse For details see:* p. 25, 26, 27, 28 Motor starter protector for motor protection and contactor 8 Motor starter protector for motor protection with relay function and contactor p. 12, 17, 21, 25, 29, 30 Motor starter protector for starter protection, contactor and overload relay Compact starter Motor starter protector for motor protection, contactor and current monitoring relay p. 11, 17, 21 p. 29, 30 p. 12, 17, 21 Short circuit Overload Switching Monitoring Fused Fuseless Solid-state switching devices Mot. starter protector for motor protection, solid-state switching device (soft starter or solid-state contactor) and curr. monit. relay Motor starter protector for starter protection, soft starter and current monitoring relay Fuse and soft starter For details see:* p. 14, 15, 19, 23 p. 19, 23 p. 26, 27, 28 Fuse, solid-state switching device and current monitoring relay Motor starter protector for motor protection and solid-state switching device (soft starter or solid-state contactor) Motor starter protector for motor protection, 3RM1 motor starter p. 14, 15, 23, 25 p. 29, 30 Short circuit Overload Switching Monitoring Fuseless * For further details and for solutions not listed here, see Catalog IC 10 Fused Fuseless Motor starter protector for motor protection with relay function, contactor and current monitoring relay Convenient power infeed and distribution: SIRIUS 3RV29 and 3RA68 infeed systems. Efficient and flexible power distribution The components of the SIRIUS modular system can be wired extremely flexibly. For sizes S00 and S0, the simplest method is to connect the components via the associated SIRIUS 3RV29 infeed system in each case. Alongside this, the 3RA68 infeed system is available in conjunction with the compact starter – both connection methods are available optionally for devices with screw and spring-loaded terminals. Individual motor starter protectors, complete load feeders, and compact starters are just clicked into the infeed systems. An entire feeder group is thus supplied with energy without any time-consuming wiring and without any risk of error: Click ‘n’ go! Alternatively, you can also use conventional wiring: by means of parallel wiring, 3-phase busbars or 8US busbar adapters with which SIRIUS load feeders can be mounted directly on a 60 mm busbar system. These diverse combination options provide you with the most effortless solution to implement your individual control cabinets – simply perfectly tailored to your application. Assembly – Highlights • New flexibility for installation and expansion • More free space in the control cabinet – thanks to extremely compact design • Infeed (3RA68) either on the left or right with conductor cross-section up to 70 mm² • Optional wiring channel between the feeders • Additional integration of further 1-, 2- or 3-pole components via terminal block • Maximum current carrying capacity of 100 A (3RA68) • Integration of load feeders with screw and spring-loaded terminals • High vibration resistance, especially for switching devices with spring-loaded terminals • Time savings during installation thanks to simple plug-in design • For 3RA68 infeed system also with PE connection option 9 Fuseless assembly 10 Assembly up to 7.5 kW (S00) Motor starter protector for starter protection, contactor with overload relay Type 1 Motor starter protector* 2 Link module 3 Contactor (AC/DC)* Motor starter protector for motor protection, contactor with current monitoring relay 1 1 2 2 3 3 4 4 Screw terminals Spring-loaded terminals 3RA1921-1DA00 3RA2911-2AA00 4 Overload relay * For the article numbers of the basic components, see overview table on page 11 Type 1 Motor starter protector* 2 Link module 3 Contactor (AC/DC)* Screw terminals Spring-loaded terminals 3RA1921-1DA00 3RA2911-2AA00 4 Current monitoring relay* * For the article numbers of the basic components, see overview table on page 12 Starter combinations in size S00: motor starter protector for starter protection, contactor and overload relay MSPs for starter protection Contactors (aux. contacts 1NO or 1NC integrated) Rated operational current Article No. Article No. [A] 24 V DC 230 V AC, 50/60 Hz Overload relays Threephase motor 400 V [kW] [A] MSP rated current [A] Article No. 0.04 0.16 0.16 3RV2311-0AC 0 0.11 – 0.16 3RU2116-0A 0 0.06 0.2 0.2 3RV2311-0BC 0 0.14 – 0.2 3RU2116-0B 0 0.06 0.25 0.25 3RV2311-0CC 0 0.18 – 0.25 3RU2116-0C 0 0.09 0.32 0.32 3RV2311-0DC 0 0.22 – 0.32 3RU2116-0D 0 0.09 0.4 0.4 3RV2311-0EC 0 0.28 – 0.4 3RU2116-0E 0 0.12 0.5 0.5 3RV2311-0FC 0 0.35 – 0.5 3RU2116-0F 0 0.18 0.63 0.63 3RV2311-0GC 0 0.45 – 0.63 3RU2116-0G 0 0.18 0.8 0.8 3RV2311-0HC 0 0.55 – 0.8 3RU2116-0H 0 0.25 1 1 3RV2311-0JC 0.7 – 1 3RU2116-0J 0 0.37 1.25 1.25 3RV2311-0KC 0 0.9 – 1.25 3RU2116-0K 0 0.55 1.6 1.6 3RV2311-1AC 0 1.1 – 1.6 3RU2116-1A 0 0.75 2 2 3RV2311-1BC 0 1.4 – 2 3RU2116-1B 0 0.75 2.5 2.5 3RV2311-1CC 0 1.8 – 2.5 3RU2116-1C 0 1.1 3.2 3.2 3RV2311-1DC 0 2.2 – 3.2 3RU2116-1D 0 1.5 4 4 3RV2311-1EC 0 2.8 – 4 3RU2116-1E 0 2.2 5 5 3RV2311-1FC 0 3.5 – 5 3RU2116-1F 0 2.2 6.3 6.3 3RV2311-1GC 0 4.5 – 6.3 3 8 8 3RV2311-1HC 0 4 10 10 3RV2311-1JC 5.5 12.5 12.5 3RV2311-1KC 0 7.5 16 16 3RV2311-4AC 0 0 0 Screw terminals: 1 Spring-loaded terminals: 2 7 3RT2015- BB4 3RT2015- AP0 Setting range CLASS 10 [A] Article No. thermal overload relay 3RU2116-1G 0 9 3RT2016- BB4 3RT2016- AP0 5.5 – 8 3RU2116-1H 0 12 3RT2017- BB4 3RT2017- AP0 7 – 10 3RU2116-1J 0 9 – 12.5 3RU2116-1K 0 11 – 16 3RU2116-4A 0 16 3RT2018- BB4 Screw terminals: 1 Spring-loaded term.: 2 Ring cable lug connection: 4 3RT2018- AP0 1NO: 1 1NC: 2 Screw terminals: B Spring-loaded terminals: C Ring cable lug connection: J Setting range CLASS 10 [A] Article No. electronic overload relay 0.1 – 0.4 3RB3016-1R 0 0.32 – 1.25 3RB3016-1N 0 1–4 3RB3016-1P 0 3 – 12 3RB3016-1S 0 4 – 16 3RB3016-1T 0 Screw terminals: B Spring-loaded terminals: E 11 Starter combinations in size S00: motor starter protector for motor protection, contactor and current monitoring relay MSPs for motor protection Contactors (aux. contacts 1NO or 1NC integrated) Rated Article No. Article No. operational current Control supply voltage [A] 24 V DC 230 V AC, 50/60 Hz Threephase motor 400 V [kW] [A] Setting range for thermal overload release [A] 0.04 0.16 0.11 – 0.16 3RV2011-0AA 0 0.06 0.2 0.14 – 0.2 3RV2011-0BA 0 Article No. 0.06 0.25 0.18 – 0.25 3RV2011-0CA 0 0.09 0.32 0.22 – 0.32 3RV2011-0DA 0 0.09 0.4 0.28 – 0.4 3RV2011-0EA 0 0.12 0.5 0.35 – 0.5 3RV2011-0FA 0 0.18 0.63 0.45 – 0.63 3RV2011-0GA 0 0.18 0.8 0.55 – 0.8 3RV2011-0HA 0 0.25 1 0.7 – 1 3RV2011-0JA 0.37 1.25 0.9 – 1.25 3RV2011-0KA 0 0.55 1.6 1.1 – 1.6 3RV2011-1AA 0 0.75 2 1.4 – 2 3RV2011-1BA 0 0.75 2.5 1.8 – 2.5 3RV2011-1CA 0 1.1 3.2 2.2 – 3.2 3RV2011-1DA 0 1.5 4 2.8 – 4 3RV2011-1EA 0 2.2 5 3.5 – 5 3RV2011-1FA 0 2.2 6.3 4.5 – 6.3 3RV2011-1GA 0 3 8 5.5 – 8 3RV2011-1HA 0 4 10 7 – 10 3RV2011-1JA 5.5 12.5 9 – 12.5 3RV2011-1KA 0 7.5 16 10 – 16 3RV2011-4AA 0 0 0 Screw terminals: 1 Spring-loaded terminals: 2 Ring cable lug connection: 4 7 3RT2015- BB4 Current monitoring relays Meas. range [A] Article No. Basic (analog adjustable) Article No. Standard (digital adjustable) 3RR2141- A 30 3RR2241- F 30 3RT2015- AP0 1.6 – 16 9 3RT2016- BB4 3RT2016- AP0 12 3RT2017- BB4 3RT2017- AP0 16 3RT2018- BB4 3RT2018- AP0 Screw terminals: 1 Spring-loaded terminals: 2 Ring cable lug connection: 4 12 1NO: 1 1NC: 2 Screw terminals: Spring-loaded terminals: 24 V AC/DC: 24 – 240 V AC/DC: 1 2 A W Screw terminals: Spring-loaded ter.: 24 V AC/DC: 24 – 240 V AC/DC: 1 2 A W Fuseless assembly with solid-state switching devices Assembly up to 7.5 kW (S00) Motor starter protector for motor protection, soft starter with current monitoring relay (stand-alone installation) 1 1 2 2 3 3 4 Type Screw terminals Spring-loaded terminals 2 Link module 3RA2921-1BA00 3RA2911-2GA00 4 Terminal support stand-alone 3RU2916-3AA01 3RU2916-3AC01 3 Soft starter* 5 Current monitoring relay*¹⁾ 4 ¹⁾ T o use a 3RR2 current monitoring relay on a 3RW30/40 soft starter, the terminal support for standalone assembly is necessary. In the starting and stopping phase (generalized phase control), the current monitoring relay shall not be active. For 3RW30: Activate the 3RR2 monitoring relay via an upstream timing relay after the end of the soft start For 3RW40: Activate/deactivate the 3RR2 monitoring relay via the BYPASS output (ramp-up detection) 5 1 Motor starter protector* Motor starter protector for motor protection, solid-state contactor with current monitoring relay (stand-alone installation) * For the article numbers of the basic components, see overview table on page 14 5 ¹⁾ T o use a 3RR2*41 curr. monit. relay of size S00, the terminal support for stand-alone assembly is necessary. Type 1 Motor starter protector* Screw terminals 2 Link module 3RA2921-1BA00 4 Terminal support stand-alone 3RU2916-3AA01 3 Solid-state cont./solid-state rev. cont.* 5 Current monitoring relay*¹⁾ * For the article numbers of the basic components, see overview table on page 15 13 Starter combinations: Motor starter protector for motor protection, soft starter with current monitoring relay (stand-alone installation: see combination options on page 13) Threephase motor 400 V [kW] [A] Motor starter protectors Setting range for thermal overload release CLASS 10 Article No. [A] 0.04 0.16 0.11 – 0.16 3RV2011-0AA 0 0.06 0.2 0.14 – 0.2 3RV2011-0BA 0 0.06 0.25 0.18 – 0.25 3RV2011-0CA 0 0.09 0.32 0.22 – 0.32 3RV2011-0DA 0 0.09 0.4 0.28 – 0.4 3RV2011-0EA 0 0.12 0.5 0.35 – 0.5 3RV2011-0FA 0 0.18 0.63 0.45 – 0.63 3RV2011-0GA 0 0.18 0.8 0.55 – 0.8 3RV2011-0HA 0 0.25 1 0.7 – 1 3RV2011-0JA 0.37 1.25 0.9 – 1.25 3RV2011-0KA 0 0.55 1.6 1.1 – 1.6 3RV2011-1AA 0 0.75 2 1.4 – 2 3RV2011-1BA 0 0.75 2.5 1.8 – 2.5 3RV2011-1CA 0 1.1 3.2 2.2 – 3.2 3RV2011-1DA 0 1.5 4 2.8 – 4 3RV2011-1EA 0 2.2 5 3.5 – 5 3RV2011-1FA 0 2.2 6.3 4.5 – 6.3 3RV2011-1GA 0 Current monitoring relays Article No. 230 V AC, 50/60 Hz 3.6 3RW3013- BB04 3RW3013- BB14 6.5 3RW3014- BB04 3RW3014- BB14 9 3RW3016- BB04 3RW3016- BB14 12.5 3RW3017- BB04 3RW3017- BB14 17.6 3RW3018- BB04 3RW3018- BB14 Meas. range [A] Article No. Basic (analog adjustable) Article No. Standard (digital adjustable) 3RR2141- A 30 3RR2241- F 30 0 3 8 5.5 – 8 3RV2011-1HA 0 4 10 7 – 10 3RV2011-1JA 5.5 12.5 9 – 12.5 3RV2011-1KA 0 7.5 16 10 – 16 3RV2011-4AA 0 ¹⁾ Rated operational voltage 200 – 480 V Soft starters¹⁾ Rated operational current Article No. [A] 24 V DC 14 0 Screw terminals: 1 Spring-loaded terminals: 2 Ring cable lug connection: 4 Screw terminals: 1 Spring-loaded terminals: 2 1.6 – 16 Screw terminals: Spring-loaded terminals: 24 V AC/DC: 24 – 240 V AC/DC: 1 2 A W Screw terminals: Spring-loaded ter.: 24 V AC/DC: 24 – 240 V AC/DC: 1 2 A W Starter combinations: motor starter protector for motor protection, solid-state switching device and current monitoring relay (stand-alone installation: see combination options on page 13) Threephase motor 400 V [kW] [A] Motor starter protectors Setting range for thermal overload release CLASS 10 Article No. [A] 0.04 0.16 0.11 – 0.16 3RV2011-0AA 0 0.06 0.2 0.14 – 0.2 3RV2011-0BA 0 0.06 0.25 0.18 – 0.25 3RV2011-0CA 0 0.09 0.32 0.22 – 0.32 3RV2011-0DA 0 0.09 0.4 0.28 – 0.4 3RV2011-0EA 0 0.12 0.5 0.35 – 0.5 3RV2011-0FA 0 0.18 0.63 0.45 – 0.63 3RV2011-0GA 0 0.18 0.8 0.55 – 0.8 3RV2011-0HA 0 0.25 1 0.7 – 1 3RV2011-0JA 0.37 1.25 0.9 – 1.25 3RV2011-0KA 0 0.55 1.6 1.1 – 1.6 3RV2011-1AA 0 0.75 2 1.4 – 2 3RV2011-1BA 0 0.75 2.5 1.8 – 2.5 3RV2011-1CA 0 1.1 3.2 2.2 – 3.2 3RV2011-1DA 0 1.5 4 2.8 – 4 3RV2011-1EA 0 2.2 5 3.5 – 5 3RV2011-1FA 0 2.2 6.3 4.5 – 6.3 3RV2011-1GA 0 3 8 5.5 – 8 3RV2011-1HA 0 4 10 7 – 10 3RV2011-1JA 5.5 12.5 9 – 12.5 3RV2011-1KA 0 7.5 16 10 – 16 3RV2011-4AA 0 ¹⁾ Width 90 mm ²⁾ Rated operational voltage Ue 48 – 480 V ³⁾ Can be mounted directly on solid-state contactor with screw terminals using connection adapter 3RF3900-0QA88 Solid-state contactors²⁾ Rated Article No. Article No. operational current Control supply voltage [A] 24 V DC 110 – 230 V AC, 50/60 Hz 0 0 Screw terminals: 1 Spring-loaded terminals: 2 Ring cable lug connection: 4 5.2 3RF3405- BB04 3RF3405- BB24 9.2 3RF3410- BB04¹⁾ 3RF3410- BB24¹⁾ 12.5 3RF3412- BB04¹⁾ 3RF3412- BB24¹⁾ 16 3RF3416- BB04¹⁾ 3RF3416- BB24¹⁾ Current monitoring relays Meas. range [A] 1.6 – 16 Screw terminals: 1 Spring-loaded terminals: 2 Solid-state reversing contactors ²⁾ 3.8 3RF3403-1BD04 3RF3403-1BD24 5.4 3RF3405-1BD04 3RF3405-1BD24 7.4 3RF3410-1BD04¹⁾ 3RF3410-1BD24¹⁾ Article No. Basic (analog adjustable) Article No. Standard (digital adjustable) 3RR2141- A 30³⁾ 3RR2241- F 30³⁾ Screw terminals: Spring-loaded terminals: 24 V AC/DC: 24 – 240 V AC/DC: 1 2 A W 15 Fuseless assembly 16 Assembly 18.5 kW (S0) Motor starter protector for starter protection, contactor and overload relay Motor starter protector for motor protection, contactor with current monitoring relay 1 1 2 2 3 3 4 4 ¹⁾ Can only be used up to 32 A Type 1 Motor starter protector* 2 Link module¹⁾ Screw terminals Spring-loaded terminals AC 3RA2921-1AA00 DC 3RA2921-1BA00 3RA2921-2AA00 3RA2921-2AA00 3 Contactor* 4 Overload relay* * For the article numbers of the basic components, see overview table on page 17 ¹⁾ Can only be used up to 32 A Type 1 Motor starter protector* 2 Link module¹⁾ Screw terminals Spring-loaded terminals AC 3RA2921-1AA00 DC 3RA2921-1BA00 3RA2921-2AA00 3RA2921-2AA00 3 Contactor* 4 Current monitoring relay* * For the article numbers of the basic components, see overview table on page 17 Starter combinations size S0: Motor starter protector for starter protection, contactor and overload relay MSPs for starter protection Contactors (auxiliary contacts 1NO or 1NC integrated) Rated Article No. Article No. Article No. operational current Control supply voltage [A] 24 V DC 230 V AC, 50 Hz 50/60 Hz AC/DC Threephase motor 400 V [kW] [A] MSP rated current [A] Article No. 7.5 16 16 3RV2321-4AC 0 7.5 20 20 3RV2321-4BC 0 11 22 22 3RV2321-4CC 0 11 25 25 3RV2321-4DC 0 15 28 28 3RV2321-4NC 0 15 32 32 3RV2321-4EC 0 18.5 36 36 3RV2321-4PC10 18.5 40 40 3RV2321-4FC10 17 25 32 38 Screw terminals: 1 Spring-loaded terminals ²⁾: 2 3RT2025- BB40 3RT2025- AP00 3RT2025- N 30 3RT2026- BB40 3RT2026- AP00 3RT2026- N 30 3RT2027- BB40 3RT2027- AP00 3RT2027- N 30 3RT2028- BB40 3RT2028- AP00 3RT2028- N 30 Screw terminals: 1 21 – 28 V AC/DC: B Spring-loaded terminals: 2 95 – 130 V AC/DC: F Ring cable lug connection: 4 200 – 280 V AC/DC: P Overload relays Setting range CLASS 10 [A] Article No. thermal overload relay 11 – 16 3RU2126-4A 0 14 – 20 3RU2126-4B 0 17 – 22 3RU2126-4C 0 20 – 25 3RU2126-4D 0 23 – 28 3RU2126-4N 0 27 – 32 3RU2126-4E 0 30 – 36 3RU2126-4P 0 34 – 40 3RU2126-4F 0 Setting range CLASS 10 [A] Article No. electronic overload relay 6 – 25 3RB3026-1Q 0 10 – 40 3RB3026-1V 0 Screw terminals: B Spring-loaded terminals: C Ring cable lug connection: J Screw terminals: B Spring-loaded terminals: E Starter combinations size S0: Motor starter protector for motor protection, contactor with current monitoring relay Threephase motor 400 V [kW] [A] ²⁾ Up to 32 A MSPs for motor protection Thermal overload release [A] Contactors (auxiliary contacts 1NO or 1NC integrated) Rated Article No. Article No. Article No. operational current Control supply voltage [A] 24 V DC 230 V AC, 50 Hz 50/60 Hz AC/DC Article No. 7.5 16 10 – 16 3RV2021-4AA 0 7.5 20 13 – 20 3RV2021-4BA 0 11 22 16 – 22 3RV2021-4CA 0 11 25 18 – 25 3RV2021-4DA 0 15 28 23 – 28 3RV2021-4NA 0 15 32 27 – 32 3RV2021-4EA 0 18.5 36 30 – 36 3RV2021-4PA10 18.5 40 34 – 40 3RV2021-4FA10 Screw terminals: 1 Spring-loaded terminals ²⁾: 2 Ring cable lug connection ²⁾: 4 17 3RT2025- BB40 3RT2025- AP00 3RT2025- N 30 25 3RT2026- BB40 3RT2026- AP00 3RT2026- N 30 Current monitoring relays Meas. range [A] 4 – 40 32 3RT2027- BB40 3RT2027- AP00 3RT2027- N 30 38 3RT2028- BB40 3RT2028- AP00 3RT2028- N 30 Screw terminals: 1 21 – 28 V AC/DC: B Spring-loaded terminals: 2 95 – 130 V AC/DC: F Ring cable lug connection: 4 200 – 280 V AC/DC: P Article No. Basic (analog adjustable) Article No. Standard (digital adjustable) 3RR2142- A 30 3RR2242- F 30 Screw terminals: Spring-loaded terminals: 24 V AC/DC: 24 – 240 V AC/DC: B C A W 17 Fuseless assembly 18 Assembly up to 18.5 kW (S0) Motor starter protector for motor protection, 3RW30 soft starter with current monitoring relay (stand-alone installation) 1 1 2 2 3 3 ¹⁾ C an only be used up to 32 A ²⁾ To use a 3RR2 current monitoring relay on a 3RW30/40 soft starter, the terminal support for stand-alone assembly is necessary. In the starting and stopping phase (generalized phase control), the current monitoring relay shall not be active. For 3RW30: Activate the 3RR2 monitoring relay via an upstream timing relay after the end of the soft start For 3RW40: Activate/deactivate the 3RR2 monitoring relay via the BYPASS output (ramp-up detection) 4 5 Type Screw terminals Spring-loaded terminals 2 Link module¹⁾ 3RA2921-1BA00 3RA2921-2GA00 4 Terminal support stand-alone 3RU2926-3AA01 3RU2916-3AC01 1 Motor starter protector* 3 Soft starter* 5 Current monitoring relay*²⁾ Motor starter protector for starter protection, 3RW40 soft starter (integrated electronic overload relay) with current monitoring relay (stand-alone installation) * For the article numbers of the basic components, see overview table on page 19 ¹⁾ C an only be used up to 32 A ²⁾ To use a 3RR2 current monitoring relay on a 3RW30/40 soft starter, the terminal support for stand-alone assembly is necessary. In the starting and stopping phase (generalized phase control), the current monitoring relay shall not be active. For 3RW30: Activate the 3RR2 monitoring relay via an upstream timing relay after the end of the soft start For 3RW40: Activate/deactivate the 3RR2 monitoring relay via the BYPASS output (ramp-up detection) 4 5 Type Screw terminals Spring-loaded terminals 2 Link module¹⁾ 3RA2921-1BA00 3RA2921-2GA00 4 Terminal support stand-alone 3RU2926-3AA01 3RU2916-3AC01 1 Motor starter protector* 3 Soft starter* 5 Current monitoring relay*²⁾ * For the article numbers of the basic components, see overview table on page 19 Starter combinations in size S0: Motor starter protector for motor protection, 3RW30 soft starter with current monitoring relay (stand-alone installation: see combination options on page 18) Threephase motor 400 V [kW] [A] MSPs for motor protection Soft starters¹⁾ without overload protection Current monitoring relays Setting range for thermal overload release CLASS 10 [A] Rated operational current [A] Control supply voltage 24 V AC/DC 110 – 230 V AC/DC Meas. range [A] 25 3RW3026- BB04 3RW3026- BB14 32 3RW3027- BB04 3RW3027- BB14 38 3RW3028- BB04 3RW3028- BB14 45 3RW3036- BB04 3RW3036- BB14 Article No. 11 22 16 – 22 3RV2021-4CA 0 11 25 18 – 25 3RV2021-4DA 0 15 28 23 – 28 3RV2021-4NA 0 15 32 27 – 32 3RV2021-4EA 0 18.5 36 30 – 36 3RV2021-4PA10 18.5 40 34 – 40 3RV2021-4FA10 18.5 40 34 – 40 3RV2021-4FA10 Article No. Article No. 4 – 40 Article No. Basic (analog adjustable) Article No. Standard (digital adjustable) 3RR2142- A 30 3RR2242- F 30 Starter combinations in size S0: Motor starter protector for starter protection, 3RW40 soft starter and current monitoring relay (stand-alone installation: see combination options on page 18) Threephase motor 400 V [kW] [A] MSPs for starter protection Soft starters¹⁾ with overload protection Current monitoring relays Setting range for thermal overload release CLASS 10 [A] Rated operational current [A] Control supply voltage 24 V AC/DC 110 – 230 V AC/DC Meas. range [A] 12.5 3RW4024- BB04 3RW4024- BB14 25 3RW4026- BB04 3RW4026- BB14 Article No. 5.5 12.5 12.5 3RV2321-1KC 7.5 16 16 3RV2321-4AC 0 7.5 20 20 3RV2321-4BC 0 11 22 22 3RV2321-4CC 0 11 25 25 3RV2321-4DC 0 15 28 28 3RV2321-4NC 0 15 32 32 3RV2321-4EC 0 18.5 36 36 3RV2321-4PC10 18.5 40 40 3RV2321-4FC10 ¹⁾ R ated operational voltage 200 – 480 V 0 Screw terminals: 1 Spring-loaded terminals up to 32 A 2 Article No. Article No. 4 – 40 32 3RW4027- BB04 3RW4027- BB14 38 3RW4028- BB02 – Screw terminals: 1 Spring-loaded terminals: 2 Article No. Basic (analog adjustable) Article No. Standard (digital adjustable) 3RR2142- A 30 3RR2242- F 30 Screw terminals: B Spring-loaded terminals: C 24 V AC/DC: A 24 – 240 V AC/DC: W 19 Fuseless assembly 20 Size S2 up to 37 kW Motor starter protector for starter protection, contactor and overload relay 1 1 2 2 3 3 4 4 5 5 Type 1 Motor starter protector* Screw terminals 2 Link module (can only be used up to 65 A) 3RA2931-1AA00 4 Terminal support for stand-alone installation 3RA2936-3AA01 3 Contactor* 5 Overload relay* Motor starter protector for motor protection, contactor with current monitoring relay * For the article numbers of the basic components, see overview table on page 17 Type 1 Motor starter protector* Screw terminals 2 Link module (can only be used up to 65 A) 3RA2931-1AA00 4 Terminal support for stand-alone installation 3RA2936-3AA01 3 Contactor* 5 Current monitoring relay* * For the article numbers of the basic components, see overview table on page 17 Starter combinations in size S2: Motor starter protector for motor protection, contactor and current monitoring relay Threephase motor 400 V [kW] [A] 18.5 40 22 52 30 65 37 80 ¹⁾ A s 3RB3133 also available with another CLASS and other functions MSPs for starter protection Rated operational current Article No. [A] 36 3RV233 -4PC10 40 3RV233 -4UC10 45 3RV233 -4VC10 52 3RV233 -4WC10 59 3RV233 -4XC10 65 3RV233 -4JC10 73 3RV233 -4KC10 80 ²⁾ 3RV233 -4RC10 Contactors (auxiliary contacts 1NO or 1NC integrated) Rated operational current Article No. Article No. [A] 230 V AC, 50 Hz 50/60 Hz AC/DC 40 3RT2035- AP00 3RT2035- N 30 50 3RT2036- AP00 3RT2036- N 30 65 3RT2037- AP00 3RT2037- N 30 80 Standard switching capacity 65 kA at 400 V: 1 Increased switching capacity 100 kA at 400 V: 2 3RT2038- AP00 3RT2038- N 30 Overload relays Article No. Setting thermal range overload relay [A] CLASS 10 22 – 32 Setting range [A] Article No. electronic overload relay CLASS 10E¹⁾ 20 – 80 3RB3036-1W 3RU2136-4EB0 28 – 40 3RU2136-4FB0 36 – 45 3RU2136-4GB0 40 – 50 3RU2136-4HB0 47 – 57 3RU2136-4QB0 54 – 65 3RU2136-4JB0 62 – 73 3RU2136-4KB0 70 – 80 3RU2136-4RB0 Screw terminals: 1 20 – 33 V AC/DC: B Spring-loaded terminals 83 – 155 V AC/DC: F in auxiliary circuit: 3 175 – 280 V AC/DC: P Contactor mounting: B C Straight-thr. transf.: X W 0 0 1 1 Starter combinations in size S2: Motor starter protector for motor protection, contactor with current monitoring relay Threephase motor 400 V [kW] [A] 18.5 40 22 52 30 65 37 80 ²⁾ S uitable for use with IE3 motors up to a starting current of 720 A. For higher starting currents we recommend using 3RV1 motor starter protectors size S3. MSPs for motor protection Thermal overload release Article No. [A] 28 – 36 3RV203 -4PA10 32 – 40 3RV203 -4UA10 35 – 45 3RV203 -4VA10 42 – 52 3RV203 -4WA10 49 – 59 3RV203 -4XA10 54 – 65 3RV203 -4JA10 62 – 73 3RV203 -4KA10 70 – 80²⁾ 3RV203 -4RA10 Standard switching capacity 65 kA at 400 V: 1 Increased switching capacity 100 kA at 400 V: 2 Contactors (auxiliary contacts 1NO or 1NC integrated) Rated current [A] Article No. 230 V AC, 50 Hz 40 3RT2035- AP00 3RT2035- N 30 50 3RT2036- AP00 3RT2036- N 30 65 3RT2037- AP00 3RT2037- N 30 80 3RT2038- AP00 3RT2038- N 30 Article No. 50/60 Hz AC/DC Screw terminals: 1 20 – 33 V AC/DC: B Spring-loaded terminals 83 – 155 V AC/DC: F in auxiliary circuit: 3 175 – 280 V AC/DC: P Current monitoring relays Article No. Meas. Basic (analog range adjustable) [A] Article No. Standard (digital adjustable) 8 – 80 3RR2243- 1F 30 3RR2143- 1A 30 24 V AC/DC: A 24 V AC/DC: A 24 – 240 V AC/DC: W 24 – 240 V AC/DC: W 21 Fuseless assembly 22 Size S2 up to 37 kW Motor starter protector for motor protection, soft starter without overload protection and current monitoring relay (stand-alone installation) 1 1 2 2 3 3 4 4 5 Type 1 Motor starter protector* ¹⁾ T o use a 3RR2 current monitoring relay on a 3RW30/40 soft starter, the terminal support for standalone assembly is necessary. In the starting and stopping phase (generalized phase control), the current monitoring relay shall not be active. For 3RW30: Activate the 3RR2 monitoring relay via an upstream timing relay after the end of the soft start Screw terminals 2 Link module (can only be used up to 65 A) 3RA2931-1AA00 4 Terminal support for stand-alone installation 3RU2936-3AA01 3 Soft starter* 5 Current monitoring relay* ¹⁾ Motor starter protector for starter protection, 3RW40 soft starter with overload protection and current monitoring relay (stand-alone installation) * For the article numbers of the basic components, see overview table on page 23 5 Type 1 Motor starter protector* ¹⁾ T o use a 3RR2 current monitoring relay on a 3RW30/40 soft starter, the terminal support for standalone assembly is necessary. In the starting and stopping phase (generalized phase control), the current monitoring relay shall not be active. For 3RW40: Activate/deactivate the 3RR2 monitoring relay via the BYPASS output (ramp-up detection) Screw terminals 2 Link module (can only be used up to 65 A) 3RA2931-1AA00 4 Terminal support for stand-alone installation 3RU2936-3AA01 3 Soft starter* 5 Current monitoring relay* ¹⁾ * For the article numbers of the basic components, see overview table on page 23 Starter combinations in size S2: Motor starter protector for motor protection, 3RW30 soft starter with current monitoring relay (stand-alone installation: see combination options on page 22) Threephase motor 400 V [kW] [A] 18.5 40 22 52 30 37 65 80 MSPs for motor protection Thermal overload release Article No. [A] 28 – 36 3RV203 -4PA10 32 – 40 3RV203 -4UA10 35 – 45 3RV203 -4VA10 42 – 52 3RV203 -4WA10 49 – 59 3RV203 -4XA10 54 – 65 3RV203 -4JA10 62 – 73 3RV203 -4KA10 70 – 80 3RV203 -4RA10 Soft starter without overload prot. Rated operational current Article No. [A] 45 3RW3036-1BB 4 63 3RW3037-1BB 4 72 3RW3038-1BB 4 Standard switching capacity 65 kA at 400 V: 1 Increased switching capacity 100 kA at 400 V: 2 Current monitoring relays Article No. Meas. Basic (analog range adjustable) [A] Article No. Standard (digital adjustable) 8 – 80 3RR2243-1F 30 3RR2143-1A 30 24 V AC/DC: 0 110 – 230 V AC/DC: 1 24 V AC/DC: A 110 – 230 V AC/DC: W Starter combinations in size S0: Motor starter protector for starter protection, 3RW40 soft starter with current monitoring relay (stand-alone installation: see combination options on page 22) Threephase motor 400 V [kW] [A] 18.5 40 22 52 30 37 65 80 MSPs for starter protection Rated operational current Article No. [A] 36 3RV233 -4PC10 40 3RV233 -4UC10 45 3RV233 -4VC10 52 3RV233 -4WC10 59 3RV233 -4XC10 65 3RV233 -4JC10 73 3RV233 -4KC10 80 3RV233 -4RC10 Standard switching capacity 65 kA at 400 V: 1 Increased switching capacity 100 kA at 400 V: 2 Soft starter with overload prot. Rated operational current Article No. [A] 45 3RW4036-1BB 4 63 3RW4037-1BB 4 72 3RW4038-1BB 4 24 V AC/DC: 0 110 – 230 V AC/DC: 1 Current monitoring relays Article No. Meas. Basic (analog range adjustable) [A] Article No. Standard (digital adjustable) 8 – 80 3RR2243-1F 30 3RR2143-1A 30 24 V AC/DC: A 110 – 230 V AC/DC: W 23 Assembly S3 up to 45 kW 24 Direct-on-line start Reversing start 5 4 6 7 5 1 Assembly kit for standard rail mounting 3RA19 43-1B Comprising: 8 1 wiring kit 5 2 rail adapters 1 7 4 6 3 side modules 7 6 connecting wedges 7 8 6 2 7 2 2 8 3 3 Type 1 Motor starter protector size S3 Version 2 2 contactors size S3 3 Mechanical interlock 4 Link module Type 1 Motor starter protector size S3 2 Link module 3 Contactor size 3 4 Standard mounting rail adapter Version Article No. AC DC 3RA19 41-1AA00 3RA19 41-1BA00 3RA19 42-1A Article No. 3RA19 24-2B AC DC 3RA19 41-1AA00 3RA19 41-1BA00 5 Standard mounting rail adapter 6 Side modules for rail adapter (1 Article No. = 100 units) 7 Connecting wedges (1 Article No. = 100 units) 8 Wiring kit: upper wiring module lower wiring module 3RA19 02-1B 8US19 98-1AA00 3RA19 43-2A Selection and ordering data S3 Threephase motor 400 V [kW] [A] 30 37 63 75 Motor starter protectors Setting range CLASS 10 [A] 42 – 63 57 – 75 Article No. 3RV1041-4JA10 3RV1041-4KA10 45 90 70 – 90 3RV1041-4LA10 45 100 80 – 100 3RV1041-4MA10 Contactors Rated operaControl tional supply current voltage [A] Article No. 65 230 V AC, 50/60 Hz 3RT1044-1AL20 65 24 V DC 3RT1044-1BB40 80 230 V AC, 50/60 Hz 3RT1045-1AL20 80 24 V DC 3RT1045-1BB40 95 230 V AC, 50/60 Hz 3RT1046-1AL20 95 24 V DC 3RT1046-1BB40 Soft starters Rated operational current Article No. [A] 80 3RW3046-1BB 4 80 3RW4046-1BB 4 24 V AC/DC: 0 110 – 230 V AC/DC: 1 Overload relays Setting range CLASS 10 [A] Article No. thermal overload relay 45 – 63 3RU1146-4JB0 57 – 75 3RU1146-4KBO Setting range [A] 25 – 100 70 – 90 3RU1146-4LB0 80 – 100 3RU1146-4MB0 Article No. electronic overload relay CLASS 10 3RB2046-1EB0* *A s 3RB2133 also available with another CLASS and other functions 25 Selection and ordering data for fused feeders of sizes S6, S10, S12 26 Size S6 Threephase motor 400 V [kW] [A] 55 115 Contactors Solenoid-operated mechanism Conventional Electronic ––for 24 V DC PLC output 75 150 ––for 24 V DC PLC output, w. RLT¹⁾ Conventional Electronic ––for 24 V DC PLC output 90 185 ––for 24 V DC PLC output, w. RLT¹⁾ Conventional Electronic ––for 24 V DC PLC output ––for 24 V DC PLC output, w. RLT¹⁾ Control supply Article No. voltage contactors [V AC/DC] 2NO+2NC 220 – 240 3RT1054-1AP36 Aux. contacts Article No. vacuum contactors – Overload relays Article No. electronic Setting overload relay range CLASS 10 [A] Version 2NO+2NC 200 – 277 3RT1054-1NP36 – 1NO+1NC 200 – 277 3RT1054-1PP35 – 2NO+2NC 220 – 240 3RT1055-6AP36 – 2NO+2NC 200 – 277 3RT1055-6NP36 – 1NO+1NC 200 – 277 3RT1055-6PP35 – 2NO+2NC 220 – 240 3RT1056-6AP36 – 2NO+2NC 200 – 277 3RT1056-6NP36 – 1NO+1NC 200 – 277 3RT1056-6PP35 – ¹⁾ R LT: remaining lifetime ²⁾ As 3RB2133 also available with another CLASS and other functions 50 – 200 50 – 200 3RB2046-1FW2²⁾ 3RB2046-1FC2²⁾ w. str.-through transf. w. busbar connection Soft starters Rated operaControl tional supply current voltage [A] Article No. 134 230 V AC 3RW4055-6BB44 134 115 V AC 3RW4055-6BB34 162 230 V AC 3RW4056-6BB44 162 115 V AC 3RW4056-6BB34 Selection and ordering data for fused feeders of sizes S6, S10, S12 Size S10 Threephase motor 400 V [kW] [A] 110 225 132 160 265 300 Contactors Conventional Control Aux. supply Article No. contacts voltage contactors [V AC/DC] 2NO+2NC 220 – 240 3RT1064-6AP36 ––for 24 V DC PLC output 2NO+2NC 200 – 277 3RT1064-6NP36 3RT1264-6NP36 Solenoid-operated mechanism Electronic ––for 24 V DC PLC output, w. RLT¹⁾ Article No. vacuum contactors 3RT1264-6AP36 2NO+2NC 220 – 240 3RT1065-6AP36 3RT1265-6AP36 ––for 24 V DC PLC output 2NO+2NC 200 – 277 3RT1065-6NP36 3RT1265-6NP36 ––for 24 V DC PLC output, w. RLT¹⁾ 1NO+1NC 200 – 277 3RT1065-6PP35 – Conventional 2NO+2NC 220 – 240 3RT1066-6AP36 3RT1266-6AP36 ––for 24 V DC PLC output 2NO+2NC 200 – 277 3RT1066-6NP36 3RT1266-6NP36 Electronic ––for 24 V DC PLC output, w. RLT¹⁾ 55 – 250 3RB2066-1GC2²⁾ Version with busbar connection 1NO+1NC 200 – 277 3RT1064-6PP35 – Conventional Electronic Overload relays Article No. electronic Setting overload relay range CLASS 10 [A] 1NO+1NC 200 – 277 3RT1066-6PP35 – Soft starters Rated operaControl tional supply current voltage [A] 230 230 280 280 160 – 630 3RB2066-1MC2²⁾ 230 V AC 115 V AC 230 V AC 115 V AC Article No. 3RW4073-6BB44 3RW4073-6BB34 3RW4074-6BB44 3RW4074-6BB34 with busbar connection 356 356 230 V AC 115 V AC 3RW4075-6BB44 3RW4075-6BB34 ¹⁾ R LT: remaining lifetime ²⁾ As 3RB2133 also available with another CLASS and other functions 27 Selection and ordering data for fused feeders of sizes S6, S10, S12 28 Size S12 Threephase motor 400 V [kW] [A] 220 400 250 500 Contactors Conventional Control Aux. supply Article No. contacts voltage contactors [V AC/DC] 2NO+2NC 220 – 240 3RT1075-6AP36 ––for 24 V DC PLC output 2NO+2NC 200 – 277 3RT1075-6NP36 3RT1275-6NP36 Solenoid-operated mechanism Electronic ––for 24 V DC PLC output, w. RLT²⁾ Conventional Electronic ––for 24 V DC PLC output ––for 24 V DC PLC output, w. RLT²⁾ Article No. vacuum contactors 3RT1275-6AP36 1NO+1NC 200 – 277 3RT1075-6PP35 – 2NO+2NC 220 – 240 3RT1076-6AP36 3RT1276-6AP36 Overload relays¹⁾ Article No. electronic Setting overload relay range CLASS 10 [A] Version Soft starters Rated operaControl tional supply current voltage [A] 432 432 160 – 630 3RB2066-1MC2³⁾ 230 V AC 115 V AC Article No. 3RW4076-6BB44 3RW4076-6BB34 with busbar connection 2NO+2NC 200 – 277 3RT1076-6NP36 3RT1276-6NP36 1NO+1NC 200 – 277 3RT1076-6PP35 – For applications over 100 A, SIRIUS contactors can be combined with SENTRON 3VL circuit breakers. For more detailed information, please refer to the configuring aid “Configuring SIRIUS load feeders in fuseless design.” ¹⁾ When using trip CLASS 20, refer to the configuration aid “Configuring SIRIUS fuseless load feeders,” and to the catalog ²⁾ RLT: remaining lifetime ³⁾ As 3RB2133 also available with another CLASS and other functions SENTRON 3VL circuit breakers are suitable for fuseless short-circuit and overload protection of soft starters from size S6. For more detailed information, please refer to the catalog. Fuseless load feeders up to 15 kW Threephase motor 400 V [kW] [A] 3RA21 direct-on-line starters Setting range for thermal overload release Type of coordination “2” at Iq = 150 kA at 400 V [A] SIRIUS 3RM1 motor starters Setting range for overload release [A] 3RA61 compact starters Setting range for overload release [A] 0.06 0.2 0.14 – 0.2 3RA2110-0B 15-1 S00 0.06 0.25 0.18 – 0.25 3RA2110-0C 15-1 S00 0.09 0.32 0.22 – 0.32 3RA2110-0D 15-1 S00 0.09 0.4 0.28 – 0.4 3RA2110-0E 15-1 S00 0.12 0.5 0.35 – 0.5 3RA2110-0F 15-1 S00 0.18 0.63 0.45 – 0.63 3RA2110-0G 15-1 S00 0.18 0.8 0.55 – 0.8 3RA2110-0H 15-1 S00 0.25 1 0.7 – 1 3RA2110-0J 15-1 S00 0.37 1.25 0.9 – 1.25 3RA2110-0K 15-1 S00 0.55 1.6 1.1 – 1.6 3RA2110-1A 15-1 S00 0.75 2 1.4 – 2 3RA2110-1B 15-1 S00 0.75 2.5 1.8 – 2.5 3RA2110-1C 15-1 S00 1.1 3.2 2.2 – 3.2 3RA2110-1D 15-1 S00 1.5 4 2.8 – 4 3RA2110-1E 15-1 S00 1.5 5 3.5 – 5 3RA2120-1F 24-0 S0 2.2 6.3 4.5 – 6.3 3RA2120-1G 24-0 S0 3 8 5.5 – 8 3RA2120-1H 24-0 S0 4 10 7 – 10 3RA2120-1J 24-0 S0 5.5 12.5 9 – 12.5 3RA2120-1K 24-0 S0 7.5 16 10 – 16 3RA2120-4A 26-0 S0 7,5 20 13 – 20 3RA2120-4B 27-0 S0 11 22 16 – 22 3RA2120-4C 27-0 S0 11 25 18 – 25 3RA2120-4D 27-0 S0 15 28 23 – 28 3RA2120-4N 27-0 S0 15 32 27 – 32 3RA2120-4E 27-0 S0 Screw terminals (standard rail mounting): Spring-loaded terminals (standard rail mounting): Screw terminals (busbar adapter): Spring-loaded terminals (busbar adapter): 24 V DC: B B 230 V AC: A P A E D H 4 0 0.1 – 0.4 3RA6120- A 3 0.32 – 1.25 3RA6120- B 3 1–4 0.1 – 0.5 3RM1 01 AA 4 0.4 – 2.0 3RM1 02 AA 4 1.6 – 7.0 (10 A)* 3RM1 07 AA 4 3RA6120- C 3 3 – 12 3RA6120- D 3 Direct-on-line starter 0 Failsafe direct-on-line starter 1 Screw terminals: 1 Spring-loaded terminals: 2 Mixed connection method: 3 8 – 32 24 V DC Us 0 110 – 230 V AC; 110 V DC Us 1 3RA6120- E 3 *Operation of resistive loads with maximum 10 A Without terminals: 0 With screw terminals: 1 With spring-loaded terminals: 2 24 V AC/DC: B 110 – 240 V AC/DC: P 0 2 2 Note: The 3RM1 motor starters do not have integral short-circuit protection. They can be used very effectively in combination with SIRIUS motor starter protectors in group assemblies, for example. 29 30 Threephase motor 400 V [kW] [A] 3RA22 reversing starters Setting range for thermal Type of coordination “2” overload release at Iq = 150 kA at 400 V [A] 3RA62 compact starters Setting range for overload release [A] 0.06 0.2 0.14 – 0.2 3RA2210-0B 15-2 S00 0.06 0.25 0.18 – 0.25 3RA2210-0C 15-2 S00 0.09 0.32 0.22 – 0.32 3RA2210-0D 15-2 S00 0.09 0.4 0.28 – 0.4 3RA2210-0E 15-2 S00 0.12 0.5 0.35 – 0.5 3RA2210-0F 15-2 S00 0.18 0.63 0.45 – 0.63 3RA2210-0G 15-2 S00 0.18 0.8 0.55 – 0.8 3RA2210-0H 15-2 S00 0.25 1 0.7 – 1 3RA2210-0J 15-2 S00 0.37 1.25 0.9 – 1.25 3RA2210-0K 15-2 S00 0.55 1.6 1.1 – 1.6 3RA2210-1A 15-2 S00 0.75 2 1.4 – 2 3RA2210-1B 15-2 S00 0.75 2.5 1.8 – 2.5 3RA2210-1C 15-2 S00 1.1 3.2 2.2 – 3.2 3RA2210-1D 15-2 S00 1.5 4 2.8 – 4 3RA2210-1E 15-2 S00 1.5 5 3.5 – 5 3RA2220-1F 24-2 S0 2.2 6.3 4.5 – 6.3 3RA2220-1G 24-0 S0 3 8 5.5 – 8 3RA2220-1H 24-0 S0 4 10 7 – 10 3RA2220-1J 24-0 S0 5.5 12.5 9 – 12.5 3RA2220-1K 26-0 S0 7.5 16 10 – 16 3RA2220-4A 27-0 S0 7.5 20 13 – 20 3RA2220-4B 27-0 S0 11 22 16 – 22 3RA2220-4C 27-0 S0 11 25 18 – 25 3RA2220-4D 27-0 S0 15 28 23 – 28 3RA2220-4N 27-0 S0 15 32 27 – 32 3RA2220-4E 27-0 S0 Screw terminals (standard rail mounting) S00: Screw terminals (standard rail mounting) S0: Spring-loaded terminals (standard rail mounting) S00: Spring-loaded terminals (standard rail mounting) S0: Screw terminals (busbar adapter): Spring-loaded terminals (busbar adapter): 24 V DC: B B 230 V AC: A P SIRIUS 3RM1 motor starters Setting range for overload release [A] 0.1 – 0.4 3RA6250- A 3 0.32 – 1.25 3RA6250- B 3 1–4 3RA6250- C 3 3 – 12 3RA6250- D 3 0.1 – 0.5 3RM1 01 AA 4 0.4 – 2.0 3RM1 02 AA 4 1.6 – 7.0 (10 A)* 3RM1 07 AA 4 Reversing starter 2 Failsafe reversing starter 3 Screw terminals: 1 Spring-loaded terminals: 2 Mixed connection method: 3 8 – 32 24 V DC Us 0 110 – 230 V AC; 110 V DC Us 1 3RA6250- E 3 *Operation of resistive loads with maximum 10 A A B E F D H 4 0 Without terminals: With screw terminals: With spring-loaded terminals: 0 2 2 0 1 2 24 V AC/DC: 110 – 240 V AC/DC: B P Note: The 3RM1 motor starters do not have integral short-circuit protection. They can be used very effectively in combination with SIRIUS motor starter protectors in group assemblies, for example. Communication connection – General and contactors Function modules for IO-Link or AS-i that are mounted on contactors (24 V DC) with communication interface are required for connecting the load feeders to the controller. Depending on the version, these communicate with an IO-Link interface group or any AS-i master. Alternatively, the contactors can be connected to the controller via IO-Link and by means of the 3RB24 overload relay. Typical configuration in the environment of IO-Link Three-phase motor 400 V [kW] [A] ET 200SP (ET 200S) with IO-Link master IO-Link 3 SIRIUS 3RA6 compact starters SIRIUS 3UG48 relays SIRIUS 3RS14/ 3RS15 relays SIRIUS 3RB24 overload relays SIRIUS 3RA2 load feeders with 3RA27 function modules SIRIUS 3RT2 contactor with SIRIUS 3RR24 relay Typical configuration in the environment of AS-Interface AS-Interface Further system components for AS-Interface 5.5 7.5 Aktoren Actuators AS-Interface Version CP343-2P communications processor for connecting SIMATIC S7-300 to AS-Interface (AS-i Spec.3.0) for up to 62 load feeders Front connector 20-pin, with screw-type contacts Front connector 20-pin, with spring-loaded contacts DP/AS-i LINK Advanced, gateway between PROFIBUS DP and AS-Interface ––Single master for up to 62 load feeders ––Double master for up to 124 load feeders AS-Interface power supply unit IP20 ––120/230 V AC 3 A ––24 V DC 3 A ––120/230 V AC 5 A ––120/230 V AC 8 A 4 7 9 12 16 3RX9501-0BA00 3RX9501-1BA00 3RX9502-0BA00 3RX9503-0BA00 See Industry Mall or Catalog IKPI 3RT2015- BB42-0CC0 1NO 3RT2015- BB41-0CC0 1NC 3RT2016- BB42-0CC0 1NO 3RT2016- BB41-0CC0 1NC 3RT2017- BB42-0CC0 1NO 3RT2017- BB41-0CC0 1NC 3RT2018- BB42-0CC0 1NO 3RT2018- BB41-0CC0 Contactors S0 with communication interface 5.5 12 1NO + 1NC 3RT2024- BB40-0CC0 16 1NO + 1NC 3RT2025- BB40-0CC0 11 25 1NO + 1NC 3RT2026- BB40-0CC0 15 32 1NO + 1NC 3RT2027- BB40-0CC0 18.5 38 1NO + 1NC 3RT2028- BB40-0CC0 Screw terminals: 1 Spring-loaded terminals S00/S0: 2 6GK7343-2AH11-0XA0 6GK1415-2BA10 6GK1415-2BA20 1NC 7.5 Article No. 6ES7392-1AJ00-0AA0 6ES7392-1BJ00-0AA0 Contactors S00 with communication interface Control supply voltage Aux. contacts Article No. 24 V DC Contactors S2 with communication interface 18.5 40 3RT2035- NB30-0CC0 22 50 3RT2036- NB30-0CC0 30 65 3RT2037- NB30-0CC0 37 80 3RT2038- NB30-0CC0 Screw terminals: 1 Spring-loaded terminals in auxiliary circuit: 3 31 Function modules for mounting on 3RT2 contactors and for connecting to the automation level 32 Parallel wiring Direct-on-line starter ON-delay OFF-delay (with aux. voltage) Reversing starter Article No. 3RA28113RA2812- Star-delta (wye-delta) starter¹⁾ ²⁾ ⁴⁾ Article No. CW10 Wiring kit for contactors S00 DW10 Wiring kit for contactors with screw terminals S0 Wiring kit for contactors S2 3RA2913-2AA 3RA2923-2AA 3RA2933-2AA Article No. 3RA2816-0EW20 Function module Wiring kit for contactors S00 3RA2913-2BB Wiring kit for contactors S0 3RA2923-2BB Wiring kit for contactors S2 3RA2933-2BB IO-Link Direct-on-line starter¹⁾ ²⁾ Reversing starter¹⁾ ²⁾ ³⁾ Article No. Function module 3RA2711- AA00 Star-delta (wye-delta) starter¹⁾ ²⁾ ⁴⁾ Article No. Function module 3RA2711- BA00 Article No. Function module 3RA2711- CA00 Wiring kit for contactors S00 3RA2913-2AA Wiring kit for contactors S00 3RA2913-2BB Wiring kit for contactors S0 3RA2923-2AA Wiring kit for contactors S0 3RA2923-2BB Wiring kit for contactors S2 3RA2933-2AA Wiring kit for contactors S2 3RA2933-2BB AS-Interface Direct-on-line starter¹⁾ ²⁾ Article No. Function module 3RA2712- Reversing starter¹⁾ ²⁾ ³⁾ AA00 Screw terminals: 1 Spring-loaded terminals: 2 Star-delta (wye-delta) starter¹⁾ ²⁾ ⁴⁾ Article No. Function module 3RA2712- BA00 Article No. Function module 3RA2712- CA00 Wiring kit for contactors S00 3RA2913-2AA Wiring kit for contactors S00 3RA2913-2BB Wiring kit for contactors S0 3RA2923-2AA Wiring kit for contactors S0 3RA2923-2BB Wiring kit for contactors S2 3RA2933-2AA Wiring kit for contactors S2 3RA2933-2BB Screw terminals: 1 Spring-loaded terminals: 2 The contactor assemblies represented above can be combined with motor starter protectors, overload relays, and monitoring relays (see the figures on the previous pages) ¹⁾ The wiring modules for the control circuit are not required ²⁾ The contactor with basic module must be implemented as a communication contactor (see page 28) ³⁾ Comprising 1 basic module and 1 coupling module ⁴⁾ Comprising 1 basic module and 2 coupling modules Screw terminals: 1 Spring-loaded terminals: 2 Communication connection – Compact starter IO-Link Setting range for electronic overload release [A] 3RA64 direct-on-line starter 0.1 – 0.4 3RA6400- AB42 3RA6500- AB42 0.32 – 1.25 3RA6400- BB42 3RA6500- BB42 1–4 3RA6400- CB42 3RA6500- CB42 3 – 12 3RA6400- DB42 3RA6500- DB42 8 – 32 3RA6400- EB42 3RA6500- EB42 CPS¹⁾ 24 V DC 3RA65 reversing starter CPS¹⁾ 24 V DC Accessories for compact starter with IO-Link, 3RA27 function modules and 3RB24 overload relays with IO-Link Module connector, 14-pole, 8 cm, for 1 space between two contactors Module connector, 14-pole, 21 cm, for diverse space combinations between two contactors Operator panel (incl. enabling module and interface cover) Connecting cable for operator panel 3RA2711-0EE02 3RA2711-0EE03 3RA6935-0A 3RA6933-0A AS-Interface Setting range for electronic overload release [A] 3RA61 direct-on-line starter 3RA62 reversing starter AS-Interface accessories CPS¹⁾ 24 V AC/DC CPS¹⁾ 24 V AC/DC AS-Interface mounting module for 3RA6 compact starter (24 V DC) 3RA6970-3A Without additional inputs/outputs AS-i addressing unit 3RK1904-2AB01 0.1 – 0.4 3RA6120- AB34 3RA6250- AB34 With two local inputs 3RA6970-3B 0.32 – 1.25 3RA6120- BB34 3RA6250- BB34 With two free external inputs 3RA6970-3C 1–4 3RA6120- CB34 3RA6250- CB34 With one free external input and one free external output 3RA6970-3D 3 – 12 3RA6120- DB34 3RA6250- DB34 With two free external outputs 3RA6970-3E 8 – 32 3RA6120- EB34 3RA6250- EB34 For local control 3RA6970-3F ¹⁾ C PS: Control and protective switching device, IEC/EN 60947-6-2 Screw terminals: 1 Spring-loaded ter.: 2 Screw terminals: 1 Spring-loaded ter.: 2 33 3RA68 infeed system (compact starter) 34 1 2 1 3 4 5 8 9 Type For busbar mounting (diagram) Infeed with screw terminals 25/35 mm² left with permanently fitted 3-socket expansion module Infeed with screw terminals 25/35 mm² left with permanently fitted 3-socket expansion module Infeed with screw terminals 50 – 70 mm² left with permanently fitted 3-socket expansion module Infeed with screw terminals 50 – 70 mm² left with permanently fitted 3-socket expansion module Terminal covers for infeed w. screw terminals Terminal covers for infeed w. screw terminals Version of terminals Article No. Screw terminals up to 63 A 3RA6812-8AB Spring-loaded terminals up to 3RA6812-8AC 63 A Screw terminals up to 100 A Spring-loaded terminals up to 3RA6813-8AC 100 A 25/35 mm² 50/70 mm² Infeed with spring-loaded terminals 25/35 mm² left or right up to 63 A 7 3 2 Expansion modules 10 3RA6830-5AC Screw terminals 3RA6822-0AB 2-socket expansion module with 2 slots Spring-loaded terminals 3RA6822-0AC 3-socket expansion module with 3 slots Screw terminals Spring-loaded terminals 4 Expansion plug between 2 expansion modules (already included in the scope of delivery of the expansion modules) 5 PE infeed 6 Item 4, 8 and 9 already included in the scope of delivery 7 8 3RA6880-2AB 3RA6880-3AB 2-socket expansion module with 2 slots 3-socket expansion module with 3 slots 6 3RA6813-8AB PE infeed 25/35 mm² PE infeed 25/35 mm² PE tap PE tap 6/10 mm² PE tap 6/10 mm² PE expansion plug 3RA6823-0AB 3RA6823-0AC Screw terminals 3RA6860-6AB Screw terminals 3RA6870-4AB Spring-loaded terminals Spring-loaded terminals 3RA6860-5AC 3RA6870-3AC Connecting wedge (already included in scope of 2 and 3 ) 9 Cover cap of the power bus (already included in scope of 1 ) Further accessories Adapter 45 mm for 3RV1/3RV2 motor starter 10 protector with screw terminals Expansion plug for SIRIUS 3RV29 infeed system Terminal block for integration of 1-, 2- or 3-pole Spring-loaded terminals components 3RA6890-0BA 3RA6890-1AA 3RV2917-5D 3RV29 infeed system (3RV2 motor starter protectors and 3RA2 load feeders) 7 8 3 4 1 1 2 9 2 Type 3-phase busbars Version For 2 motor starter protectors S00, S0 3RV2917-1A With infeed on the right incl. 3RV2917-6A end cover For 2 motor starter protectors S00, S0 3RV2917-1E For system expansion incl. 3RV2917-5BA00 expansion plug For 2 motor starter protectors S00, S0 3RV2917-4A For system expansion incl. 3RV2917-5BA00 expansion plug For 3 motor starter protectors S00, S0 3RV2917-4B 1 unit 10 units 1 unit 10 units 1 unit 10 units 1 unit 10 units S00 3RV2917-5CA00 S00 3RV2917-5C S00 3RV2917-5AA00 S00 3RV2917-5A S0 3RV1927-5AA00 S0 3RV1927-5A S0 3RV2927-5AA00 S0 3RV2927-5A Contactor base for assembling direct-on-line or reversing starters or preassembled 3RA2 load feeders 1 unit S00 3RV2917-7AA00 Contactor base for assembling direct-on-line or reversing starters or preassembled 3RA2 load feeders 1 unit S00/S0 3RV2927-7AA00 For contacting the motor starter protectors Screw terminals Spring-loaded terminals 6 4 Screw terminals Spring-loaded terminals 5 Accessories 5 6 7 8 9 Article No. With infeed on the left incl. 3RV2917-6A end cover Plug-in connectors 3 Size for 3RV20, 3RV23 motor starter protectors Terminal block for integration of 1-, 2- or 3-pole components 3RV2917-5D Standard mounting rail, 45 mm, for integrating other devices into the system, such as 5SY miniature circuit breakers 3RV1917-7B Extra-wide expansion plug 3RV2917-5E Expansion plug End cover 3RV2917-5BA00 3RV2917-6A Spare parts 35 3-phase busbars / 8US busbar adapters for infeed Type 3-phase busbars For infeed to several 3RV2 motor starter protectors (screw terminals) mounted side-by-side on standard rails, with touch protection For 2 motor starter protectors 1 For 3 motor starter protectors For 4 motor starter protectors For 5 motor starter protectors 3-phase infeed terminals 2 Connection from above Connection from below Size Article No. S00, S0 Modular spacing 45 mm 3RV1915-1AB Modular spacing 55 mm 3RV1915-2AB Modular spacing 63 mm 3RV1915-3AB Modular spacing 75 mm – S00, S0 3RV1915-1BB 3RV1915-2BB – – S2 Accessories Cover caps for connection tags Touch protection for empty positions – S2 – S2 – S00, S0 S00, S0 3RV1915-1CB 3RV1915-1DB S00, S0 3RV2925-5AB S00, S0 3RV2915-5B S2 3-phase infeed terminals for constructing type E starters Connection from above 36 S00, S0 S2 S00, S0 S2 3RV1935-1A 3RV1935-1B 3RV1915-2CB 3RV1935-1C 3RV1915-2DB – – 3RV1915-3CB – – 3 3RV1935-3A Rated operational Adapter Adapter For MSPs, current length width size [A] [mm] [mm] Article No. Busbar adapters for 60-mm systems For motor starter protectors and load feeders with screw terminals 45 8US1251-5DS10 S00, S0 25 200 S0 S2 3RV1935-3B S2 – 32 80 80 260 200 260 45 55 55 8US1251-5NT10 8US1261-5MS13 8US1261-6MT10 S2¹⁾ 80 260 118 8US1211-6MT10 For motor starter protectors and load feeders with spring-loaded terminals S00, S0 25 200 45 8US1251-5DS11 3RV1935-3C – S00, S0 3RV2935-5A S0 25 32 260 260 45 45 8US1251-5DT11 8US1251-5NT11 ¹⁾ F or the assembly of feeders for reversing starters comprising a motor starter protector and two contactors 3RV2925-5EB 3RV2935-5E Accessories 4 3RV1915-6AB 3RV1935-6A 1 2 3 4 Device holder 200 for lateral mounting 260 on busbar adapters Side module for widening busbar 200 adapters Spacer for fixing the feeder onto the busbar adapter Vibration and shock kit for increased vibration and shock loads S00/S0 S2 45 8US1250-5AS10 45 8US1250-5AT10 9 8US1998-2BJ10 8US1998-1BA10 8US1998-1CA10 8US1998-1DA10 Accessories for 3RV2 motor starter protectors (S00, S0, S2) Article No. screw Type Version terminals Accessories for 3RV motor starter protectors sizes S00, S0, S2 Auxiliary and signaling switches 7 1 3 2 4 5 1 6 Signaling switch Auxiliary releases Shunt release¹⁾ Undervoltage release¹⁾ Undervoltage release with leading auxiliary contacts 6 2NO 3RV2901-1F 3RV2901-2F – 3RV2901-1E 3RV2901-1G 3RV2901-1A 3RV2901-1B 3RV2901-1C 3RV2901-1J 3RV2921-1M 3RV2901-2E – 3RV2901-2A 3RV2901-2B 3RV2901-2C – 3RV2921-2M 3RV2901-4E – 3RV2901-4A – – – 3RV2921-4M 20 – 70 V AC/DC 3RV2902-1DB0 3RV2902-2DB0 – 230 V AC 3RV2902-2AP0 3RV2902-4AP0 210 – 240 V AC 3RV2902-1DP0 400 V AC 3RV2902-1AV0 230 V AC 3RV2902-1AP0 3RV2922-1CP0 3RV2902-2DP0 3RV2902-2AV0 3RV2922-2CP0 3RV2902-4AV0 – 3RV2922-1CV0 S00, S0 3RV2928-1A – – S00, S0 3RV2928-1H – – S00, S0 S2 3RV2928-1K 3RV2938-1K – – – – Type Version Article No. Door-coupling rotary operating mech. (black) with extension shaft²⁾ 130 mm 3RV2926-0B EMERGENCY-STOP door-cpl. rot. oper. mech. (red/yellow) w. ext. shaft²⁾ 130 mm 3RV2926-0C Isolator module Terminal block type E f. incr. clearances/creepage distances Phase barriers f. incr. clearances/creepage distances 415 V AC S2 3RV2922-1CV1 3RV2938-1A Door-coupling rotary operating mechanisms Door-coupling rotary operating mech. (black) with extension shaft EMERGENCY-STOP door-cpl. rot. oper. mech. (red/yellow) w. ext. shaft Molded-plastic enclosures for surface mounting For motor starter protector (+ lateral auxiliary switch) S00, S0 For motor starter protector (+ lateral aux. switch + auxiliary release) S00, S0 For motor starter protector (+ lateral auxiliary switch + auxiliary release) S2 Molded-plastic enclosure for surface mounting with EMERGENCY-STOP door-cpl. rot. op. mech. f. MSP (+ lateral aux. switch) S00, S0 Molded-plastic enclosure for surface mounting w. EMERGENCY-STOP door-cpl. rot. op. mech. f. MSP (+ lateral aux. switch + aux. release) S00, S0 Molded-plastic enclosure for surface mounting w. EMERGENCY-STOP door-cpl. rot. oper. mech. f. MSP (+ lateral aux. switch + aux. release) S2 ¹⁾ Other versions on request 3RV2922-2CV0 – 400 V AC Isolator module and terminal blocks 7 – 1CO 1NO + 1NC 2NO 2NC 2NO + 2NC Lateral auxiliary switch with 4 contacts 5 – Solid-state-compatible auxiliary switch 3 4 3RV2901-1D 1NO + 1NC Lateral auxiliary switch with 2 contacts Article No. ring cable lug connection 1CO Transverse auxiliary switch 2 Article No. spring-loaded terminals 3RV2922-2CV1 – 330 mm 330 mm – 3RV2922-4CV1 – 3RV2926-0K 3RV2926-0L 54 mm 72 mm 82 mm 3RV1923-1CA00 3RV1923-1DA00 3RV1933-1DA00 54 mm 3RV1923-1FA00 72 mm 3RV1923-1GA00 82 mm 3RV1933-1GA00 ²⁾ The operating mechanism is also suitable for 3RA6 compact starters 37 Accessories for 3RV1 motor starter protectors (S3) 38 Type Version Accessories for 3RV1 motor starter protectors size S3 2 Auxiliary and signaling switches 4 7 1 6 2 Lateral auxiliary switch with 2 contacts 3 Lateral auxiliary switch with 4 contacts 5 Undervoltage release Undervoltage release with leading auxiliary contacts Signaling switch 4 6 7 1 3 5 Transverse auxiliary switch Shunt release For size Article No. 1CO S3 3RV1901-1D 2NO S3 3RV1901-1F 1NO + 1NC 1NO + 1NC 2NO 2NC 2NO + 2NC 230 V AC 230 V AC 230 V AC S3 S3 S3 S3 S3 S3 S3 3RV1901-1E 3RV1901-1A 3RV1901-1B 3RV1901-1C 3RV1901-1J 3RV1902-1DP0 3RV1902-1AP0 S3 3RV1922-1CP0 S3 3RV1921-1M Accessories for 3RT201 contactors (S00) 5 6 7 1 13 2 2 10 3 8 3 1NC 1-pole auxiliary switch block, cable entry from below 1NC 3RH2911-1BA01 – 2NO 3RH2911-1LA20 – 3RH2911-1MA20 – – 3RH2911-2HA02 3RH2911-4HA02 2-pole auxiliary switch block, cable entry from above 2-pole auxiliary switch block, cable entry from below 1- to 4-pole auxiliary switch block 10 1NO 1NO 1NO + 1NC Solid-state-compatible auxiliary switch blocks 2-pole 8 5 9 6 7 3RH2911-1BA10 3RH2911-1LA11 3RH2911-1MA11 1NC 3RH2911-1HA01 2NO 1NO + 1NC 2NO + 2NC 3RH2911-1HA02 3RH2911-1HA11 – – – – – – 3RH2911-2HA01 – 3RH2911-4HA01 3RH2911-2HA10 3RH2911-4HA10 3RH2911-1HA20 3RH2911-2HA20 1NO + 1NC 3RH2911-1NF11 3RH2911-2NF11 3RH2911-1NF02 3RH2911-2NF02 3RH2911-1NF20 – 3RH2911-4HA11 3RH2911-2HA22 3RH2911-1HA10 2NO – 3RH2911-2HA11 3RH2911-1HA22 1NO 2NC – – 3RH2911-2NF20 3RH2911-4HA22 3RH2911-4HA20 – – – 8 see page 32 (function modules for mounting on contactors and for connecting to the automation level) 2NO 3RH2911-1DA20 3RH2911-2DA20 – Laterally mountable auxiliary switch blocks Solid-state-compatible auxiliary switch block laterally mountable, right Solder pin adapter for contactors with 4-pole auxiliary switch block 10 Solder pin adapter for contactors Surge suppressor, e.g. varistor 11 Without LED With LED 12 3RH2911-1AA01 1NO + 1NC 2NO 12 9 – 1-pole auxiliary switch block, cable entry from above 4 11 3RH2911-1AA10 Article No. ring cable lug connection Version Standard 2NC 1 Article No. spring-loaded terminals Fitting of auxiliary switches on the front for 3RT2 contactors 1 4 Article No. screw terminals Terminal module for contactor with screw terminals 13 3-phase infeed terminal 1NO + 1NC 3RH2911-1DA11 3RH2911-2DA11 3RH2911-2DA02 – 1NO + 1NC – 3RH2911-2DE11 – 3RT1916-4KA2 – 3RT1916-4KA1 – 127 – 240 V AC 3RT2916-1BD00 3RT2916-1BD00 Adapter 3RT1916-4RD01 2NC For 4 contactors (package) For 4 contactors (package) 127 – 240 V AC Plug Conductor crosssection: 6 mm 3RH2911-1DA02 3RT2916-1JL00 3RT2916-1JL00 3RH2911-4DA11 – 3RT2916-1BD00 3RT2916-1JL00 3RT1900-4RE01 – – – 3RA2913-3K – – – 39 Accessories for 3RT202 contactors (S0) 5 40 1 13 5 9 5 1 3 12 1 2 1NO 3RH2911-1AA10 – – 1-pole auxiliary switch block, cable entry from below 1NO 3RH2911-1BA10 – – 2-pole auxiliary switch block, cable entry from above 1NO + 1NC 2-pole auxiliary switch block, cable entry from below 1NO + 1NC Version Standard 1-pole auxiliary switch block, cable entry from above 1NC 1- to 4-pole auxiliary switch block 4 10 13 1NC 2NO 2NO 5 9 10 1NO + 1NC 2NO + 2NC 1NO 2NO Solid-state-compatible auxiliary switch blocks 2-pole 11 8 Article No. ring cable lug connection 1NC 5 3 7 Article No. spring-loaded terminals 2NC 4 6 2 Article No. screw terminals Fitting of auxiliary switches on the front for 3RT2 contactors 6 1NO + 1NC 2NO 2NC 3RH2911-1AA01 3RH2911-1BA01 3RH2911-1LA11 3RH2911-1LA20 3RH2911-1MA11 3RH2911-1MA20 – – – – – – – – 3RH2911-1HA01 3RH2911-2HA01 3RH2911-4HA01 3RH2911-1HA11 3RH2911-2HA11 3RH2911-4HA11 3RH2911-1HA02 3RH2911-1HA22 3RH2911-1HA10 3RH2911-1HA20 3RH2911-1NF11 3RH2911-1NF20 3RH2911-1NF02 3RH2911-2HA02 3RH2911-2HA22 3RH2911-2HA10 3RH2911-2HA20 3RH2911-2NF11 3RH2911-2NF20 3RH2911-2NF02 3RH2911-4HA02 3RH2911-4HA22 3RH2911-4HA10 3RH2911-4HA20 – – – 7 8 see page 32 (function modules for mounting on contactors and for connecting to the automation level) 2NO 3RH2921-1DA20 3RH2921-2DA20 – Laterally mountable 1NO + 1NC 3RH2921-1DA11 3RH2921-2DA11 3RH2921-4DA11 auxiliary switch blocks 2NC 3RH2921-1DA02 3RH2921-2DA02 – Solid-state-compatible auxiliary 1NO + 1NC – 3RH2921-2DE11 – switch block, laterally mountable Surge suppressor, e.g. varistor Without LED With LED Terminal module 11 for contactor with screw terminals Pneumatic 12 delay block 1NO + 1NC 13 Coil terminal module 127 – 240 V AC 3RT2926-1BD00 Plug 3RT1900-4RE01 ON-delay, 0.1 – 30 s 3RT2926-2PA01 – – OFF-delay, 0.1 – 30 s 3RT2926-2PR01 – – 127 – 240 V AC Adapter ON-delay, 1 – 60 s OFF-delay, 1 – 60 s Connection from above Connection from below Connection diagonally 3RT2926-1JL00 3RT1926-4RD01 3RT2926-2PA11 3RT2926-2PR11 3RT2926-4RA11 3RT2926-4RB11 3RT2926-4RC11 3RT2926-1BD00 3RT2926-1JL00 – 3RT2926-1BD00 3RT2926-1JL00 – – – – 3RT2926-4RA12 3RT2926-4RB12 3RT2926-4RC12 – – – – – Accessories for 3RT203 contactors (S2) 5 1 11 9 2 5 1 3 2 1 Article No. screw terminals Article No. spring-loaded terminals Article No. ring cable lug connection 1NO 3RH2911-1AA10 – – 1-pole auxiliary switch block, cable entry from below 1NO 3RH2911-1BA10 – – 2-pole auxiliary switch block, cable entry from above 1NO + 1NC 2-pole auxiliary switch block, cable entry from below 1NO + 1NC Fitting of auxiliary switches on the front for 3RT2 contactors Version Standard 1-pole auxiliary switch block, cable entry from above 1NC 10 5 1- to 4-pole auxiliary switch block 4 1NO + 1NC 2NO + 2NC 1NO 2NO Solid-state-compatible auxiliary switch blocks 2-pole 11 8 2NO 2NC 3 7 2NO 1NC 4 6 1NC 2NO 2NC 3RH2911-1BA01 3RH2911-1LA11 3RH2911-1LA20 3RH2911-1MA11 3RH2911-1MA20 – – – – – – – – 3RH2911-1HA01 3RH2911-2HA01 3RH2911-4HA01 3RH2911-1HA11 3RH2911-2HA11 3RH2911-4HA11 3RH2911-1HA02 3RH2911-1HA22 3RH2911-1HA10 3RH2911-1HA20 3RH2911-1NF11 3RH2911-1NF20 3RH2911-1NF02 3RH2911-2HA02 3RH2911-2HA22 3RH2911-2HA10 3RH2911-2HA20 3RH2911-2NF11 3RH2911-2NF20 3RH2911-2NF02 3RH2911-4HA02 3RH2911-4HA22 3RH2911-4HA10 3RH2911-4HA20 – – – 8 see page 32 (function modules for mounting on contactors and for connecting to the automation level) 2NO 3RH2921-1DA20 3RH2921-2DA20 – Laterally mountable 1NO + 1NC 3RH2921-1DA11 3RH2921-2DA11 3RH2921-4DA11 auxiliary switch blocks 9 2NC 3RH2921-1DA02 3RH2921-2DA02 – Solid-state-compatible auxiliary 1NO + 1NC – 3RH2921-2DE11 – switch block, laterally mountable Surge suppressor, 127 – 240 V AC e.g. varistor (230 V AC) 10 Without LED 3RT2936-1BD00 3RT2926-1BD00 3RT2926-1BD00 5 6 1NO + 1NC 3RH2911-1AA01 7 With LED 11 Coil terminal module 127 – 240 V AC Connection from above Connection from below Connection diagonally 3RT2936-1JL00 3RT2926-1JL00 3RT2926-1JL00 3RT2926-4RA11 3RT2926-4RA12 – 3RT2926-4RB11 3RT2926-4RB12 – 3RT2926-4RC11 3RT2926-4RC12 – 41 Accessories for 3RT1 contactors (S3) 42 1 2 2 3 15 16 3 9 1 10 14 10 1 4 7 4 8 13 17 6 11 14 3RT10 contactors, size S3 Electronic timing relay block, ON-delay Electronic timing relay block, OFF-delay Auxiliary switch block, solid-state time delay ON-delay OFF-delay 2-pole auxiliary switch block, 5 cable entry from above 2-pole auxiliary switch block, 6 cable entry from below 7 4-pole auxiliary switch block Links for paralleling (star jumper) 3-pole, 8 without connection terminal Links for paralleling 3-pole, 9 with connection terminal 2-pole auxiliary switch block, laterally 10 mountable on the right or left 11 5 Type 1-pole auxiliary switch block (max. 4 can be snapped on) 12 Mechanical interlock, laterally mountable Mechanical interlock, can be mounted 13 on the front Wiring modules at top or bottom 14 (reversing duty) Surge suppressor 15 (varistor, RC element, diode combination), can be mounted at top or bottom Coupling link for direct mounting on the 16 contactor coil 17 LED module for indicating contactor function Version Article No. 0.5 – 10 s 3RT19 26-2CH21 0.5 – 10 s 3RT19 26-2DH21 0.5 – 10 s 3RT19 26-2ED21 1NO + 1NC 3RH19 21-1LA11 1NO + 1NC 3RH19 21-1MA11 2NO + 2NC 3RH19 21-1HA11 0.5 – 10 s 3RT10 25-1AP00 3RT19 26-2FL21 3RT19 46-4BA31 3RT19 46-4BB31 1NO + 1NC 3RH19 21-1DA11 1NO 3RH19 21-1CA10 – 3RA19 24-2B 1NC 3RH19 21-1CA01 – 3RA19 24-1A – 3RA19 43-2A – 3RT19 26-1BD00 – 3RT19 26-3AB31 – 3RT19 26-1QT00 Accessories for 3RT1 contactors (S6 – S12) Type 2-pole auxiliary switch block, lateral 7 1 8 2 1 11 6 3 9 4 2 4 5 5 6 3 10 8 ––2nd block (left/right) 4-pole auxiliary switch block, on front ––With sequence digit 5 … 8 4 5 2 3 4 2 1 5 3RT10 and 3RT14 air-break contactor, sizes S6, S10 and S12 3RT12 vacuum contactor, sizes S10 and S12 Withdrawable coils for contactors with 3RT1…-.A.. conventional op. mech. Withdrawable coils for contactors with 3RT1…-.N.. electronic op. mech. Withdrawable coils and lateral mounting module (snap-on) for 3RT1…-.P.. contactors w. el. oper. mech. and remaining lifetime signal 3RH1921-1KA20 3RH1921-1XA22-0MA0 3RH1921-1HA22 1-pole auxiliary switch block, on front (max. 4 can be snapped on) 1NC 3RH1921-1CA01 2-pole auxiliary switch block, on front cable entry from above 2-pole auxiliary switch block, on front cable entry from below Auxiliary switch block, solid-state time delay ––ON-delay, 200 – 240 V AC ––OFF-delay, 200 – 240 V AC RC element, 127 – 240 V AC¹⁾ 8 Wiring modules Top and bottom (reversing duty) S6 S10 S12 Article No. 75 3RT1055-6LA06 90 1NO + 1NC 3RH1921-1MA11 1NO + 1NC 0 … 10 s 3RH1926-2ED21 0.5 … 10 s 3RH1926-2FL21 For S6 3RA1953-2M For S10/S12 kW 110 132 160 200 250 3RH1921-1LA11 For S6 Contactor without coil 3RH1921-1CA10 1NO + 1NC For S12 Three-phase motor 400 V 55 1NO For S10 Terminal cover for box terminals Size 1 2NO + 2NC 3RH1921-1JA11 3RH1921-1KA11 2NO + 2NC 11 Mechanical interlock 3 2NO Article No. ––With sequence digit 1 … 4 Terminal cover for cable lug and busbar 10 connections Operating mechanism types 1NO + 1NC 1NO + 1NC ––2nd block (left/right) 7 9 Version For S6 For S10/S12 3RT1956-1CD00 3RA1963-2A 3RA1973-2A 3RT1956-4EA2 3RT1966-4EA2 3RT1956-4EA2 3RT1966-4EA2 3RA1954-2A Withdrawable coil for op. mech. Conventional Electronic Control supply voltage 3RT1054-1LA06 3RT1056-6LA06 3RT1064-6LA06 3RT1065-6LA06 3RT1066-6LA06 3RT1075-6LA06 3RT1076-6LA06 220 – 240 V AC/DC 200 – 277 V AC/DC Article No. Article No. 3RT1965-5AP31 3RT1965-5NP31 3RT1975-5AP31 3RT1975-5NP31 3RT1955-5AP31 3RT1955-5NP31 ¹⁾ For more surge suppressors, see the Industry Mall or Catalog IC 10 5 43 Accessories for 3RU21 thermal overload relays, 3RB30/31 electronic overload relays and 3RR2 current monitoring relays (S00, S0, S2) Version 44 Can be combined with the following overload and current monitoring relays 3RU2 3RB3 3RR2 For size Article No. S00 3RU2916-3A 01 S0 3RU2926-3A 01 S2 3RU2936-3AA01 Resetting plungers, holders and formers S00, S0, S2 3RU2900-1A Resetting plungers, holders and formers S00, S0, S2 3RB3980-0A Terminal supports for stand-alone installation Screw fixing and snap-on mounting onto TH 35 standard mounting rail Screw fixing and snap-on mounting onto TH 35 standard mounting rail Screw fixing and snap-on mounting onto TH 35 standard mounting rail Mechanical RESET comprising: Push buttons with extended stroke (12 mm), S00, S0, S2 3SB3000-0EA11 IP65, Ø 22 mm Extension plungers for compensation of the distance between a S00, S0, S2 3SX1335 push button and the unlatching button of the relay Cable releases with holders for RESET for drill holes Ø 6.5 mm in the control panel Length 400 mm S00, S0, S2 3RU2900-1B Length 400 mm S00, S0, S2 3RB3980-0B Length 600 mm S00, S0, S2 3RU2900-1C Length 600 mm S00, S0, S2 3RB3980-0C For covering the setting knobs S00, S0, S2 3RV2908-0P For covering the setting knobs S00, S0, S2 3RB3984-0 For covering the setting knobs S00, S0, S2 3RR2940 24 – 30 V AC/DC S00, S0, S2 3RU1900-2AB71 110 – 127 V AC/DC S00, S0, S2 3RU1900-2AF71 220 – 250 V AC/DC S00, S0, S2 3RU1900-2AM71 Sealable cover for 3RB3, 3RU2, 3RR2, transparent Modules for electrical remote reset Screw terminals: A Spring-loaded terminals: C Accessories for 3RU11 thermal overload relays and 3RB20/21 electronic overload relays 1 1 2 2 3 3 4 4 Version For covering the setting knobs Terminal covers for 3RU11 and 3RB20/21 5 6 6 Covers for cable lugs and busbar connections Covers for box terminals Cover for screw terminals between contactor and overload relay without box terminals (1 unit required per combination) Box terminal block 7 7 Article No. 3RU1946-3AA01 Resetting plungers, holders and formers 3RU1900-1A Push buttons with extended stroke (12 mm), 3SB3000-0EA11 IP65, Ø 22 mm S3 – S12 Extension plungers for compensation of the distance between a push button and the unlatching button of the 3SX1335 relay Cable releases with holders for RESET for 3RU11 and 3RB20/21 for holes Ø 6.5 mm in the control panel, max. control panel thickness 8 mm Length 400 mm 3RU1900-1B S3 – S12 Length 600 mm 3RU1900-1C Sealable cover for 3RB20/21, transparent 5 For size Terminal supports for stand-alone installation for 3RU11 Screw fixing and snap-on mounting onto a TH 35 standard mounting rail size S3 also for T75 standard S3 mounting rail Mechanical RESET for 3RU11 and 3RB20/21 comprising: S3 – S12 3RB2984-0 S3 3RT1946-4EA1 S10/S12 3RT1966-4EA1 S6 S3 S6 S10/S12 S6 3RT1956-4EA1 3RT1946-4EA2 3RT1956-4EA2 3RT1966-4EA2 3RT1956-4EA3 S10/S12 3RT1966-4EA3 For round and ribbon cable conductors up to 70 mm² S6 3T1955-4G For round and ribbon cable conductors up to 240 mm² S10/S12 3T1966-4G For round and ribbon cable conductors up to 120 mm² S6 3T1956-4G 45 46 Planning Efficiency Planning Efficiency™ from Siemens provides you with seamless support throughout your entire process sequence – from the concept, through the design, all the way to commissioning and service. New standards and directives, tight deadlines and increasingly strict quality requirements – control cabinet builders are facing substantial changes in their everyday work. Planning Efficiency helps you structure your processes even more efficiently, round-the- clock. Helpful online functions are provided in each process phase – at no charge. Benefit from Planning Efficiency by achieving time savings and optimizing workflows. Planning Efficiency provides you with easy access to product information and product data worldwide and at any time. This simplifies your product selection and the integration of product data into your CAE and CAD system. Use the time you save to come up with new ideas and innovations. Your benefits with Planning Efficiency: Get to the right product faster with intuitive product selection Time savings of up to 80% with universal product data for your CAE and CAD system User-friendly compilation of project-specific documentation Comprehensive support – anywhere, anytime • Full selection of products and systems on the basis of technical features or in accordance with application requirements • No manual data collection necessary • Compile and structure manuals, data sheets, FAQs and certificates simply by dragging and dropping • FAQs, application examples, information on successor products and product innovations • Insert your own content via the Notes function • Fast support for technical inquiries • Further processing possible thanks to selectable export formats (pdf, xml, rtf) • Discuss and share experiences with users in the Forum • Simple and intuitive operation • Configuration and ordering lists can be saved in the file format of your choice (txt, pdf, xls, csv) • Direct transfer of the ordering list to the Siemens Industry Mall shopping cart • Fast access to product data for the selected product and system configuration • Availability in several languages facilitates global use • Universal manufacturer data for all commonly used CAE and CAD systems • Simple generation of standardcompliant documentation • Selection of the desired languages enables global commissioning • After generating the documentation, automatic translation into the desired language is possible • Always up-to-the-minute with the Update function • Provision of high-quality product data for your planning programs • Find information faster – with helpful filtering and folder functions in mySupport • Automatic notifications when new information appears for your preferred topics To obtain the right product for your application, Siemens offers you initial product highlights on the websites. Comprehensive application examples can also be found in the Siemens Industry Online Support. Configurators for products and systems represent another important aid in selecting the right components. With the CAx Download Manager, all the CAx data types required for use in all commonly used CAE and CAD systems are provided for your desired products in just four selection steps, free of charge and with daily updates. Your individual download package is then available to you for further use as a zip file. With just a few clicks, the respective configurator will guide you to the right product or system for your requirements. Simply enter the relevant parameters and select your solution. This means time savings of up to 80% when integrating your product data into your CAE and CAD system. Product data relevant to the configured solution are available for mechanical and electrical planning, e.g. 3D models, circuit diagrams, certificates, and operating instructions. In addition, the resulting product list can also be exported to Excel, or transferred to the Siemens Industry Mall shopping cart for ordering. In accordance with directives, the documentation is part of the system and requires certification, giving the purchaser the right to full plant documentation. To support you in this, a manual configurator has been developed with which you can implement individualized and standard-compliant documentation – fully in accordance with the relevant project-specific requirements. You can thus select the chapters relevant to the respective product from the available manuals of the installed Siemens components. FAQs, certificates, data sheets, and your own content, can also be integrated. This means the documentation is perfectly tailored to individual needs, and consequently, the information is easier to locate. Whether you need help with implementing your project, or you want to expand your plant, or plan a new one: With Siemens Industry Online Support, you receive 24/7 technical support as well as access to all the necessary product information and data. The one-time registration process is free. Then you can use the full range of functions, and profit from the helpful online functions in mySupport. Questions and requests regarding all aspects of planning and design can also be discussed with our experts in the Online Forum. The configurators are available online in the Siemens Industry Mall and offline in the CA01 Catalog. Product selection doesn’t come any faster, clearer or simpler. 47 You can find more information with the QR code Siemens AG Digital Factory Control Products P.O. Box 23 55 90713 Fürth Germany Subject to change without prior notice 02/15 Article No.: E20001-A380-P302-V9-7600 Dispo 27601 WÜ/63116 WS 02154. Printed in Germany © Siemens AG 2015 The information provided in this brochure contains merely general descriptions or characteristics of performance which in case of actual use do not always apply as described or which may change as a result of further development of the products. An obligation to provide the respective characteristics shall only exist if expressly agreed in the terms of contract. All product designations may be trademarks or product names of Siemens AG or supplier companies whose use by third parties for their own purposes could violate the rights of the owners.