5962-03A06 (for T7908E) - Standard Microcircuit Drawing

REVISIONS
LTR
DESCRIPTION
A
DATE (YR-MO-DA)
APPROVED
07-03-06
Thomas M. Hess
Update boilerplate in according with MIL-PRF-38535 requirement.
Editorial changes throughout. - phn
REV
SHEET
REV
SHEET
REV STATUS
REV
A
OF SHEETS
SHEET
1
PMIC N/A
PREPARED BY
2
A
A
3
4
5
Phu H. Nguyen
STANDARD
MICROCIRCUIT
DRAWING
6
7
8
9
10
11
A
A
12
13
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43216
http://www.dscc.dla.mil
CHECKED BY
Phu H. Nguyen
APPROVED BY
THIS DRAWING IS AVAILABLE
FOR USE BY ALL
DEPARTMENTS
AND AGENCIES OF THE
DEPARTMENT OF DEFENSE
Thomas M. Hess
DRAWING APPROVAL DATE
MICROCIRCUIT, DIGITAL, CMOS GATE ARRAY
BASED ON CAN ASIC SPACE APPLICATION
(CASA2), MONOLITHIC SILICON
03-08-11
AMSC N/A
REVISION LEVEL
A
DSCC FORM 2233
APR 97
SIZE
CAGE CODE
A
67268
SHEET
1 OF
5962-03A06
13
5962-E285-07
1. SCOPE
1.1 Scope. This drawing documents two product assurance class levels consisting of high reliability (device classes Q and M)
and space application (device class V). A choice of case outlines and lead finishes are available and are reflected in the Part or
Identifying Number (PIN). When available, a choice of Radiation Hardness Assurance (RHA) levels are reflected in the PIN.
1.2 PIN. The PIN is as shown in the following example:
5962
-
03A06
Federal
stock class
designator
\
RHA
designator
(see 1.2.1)
01
Q
X
C
Device
type
(see 1.2.2)
Device
class
designator
(see 1.2.3)
Case
outline
(see 1.2.4)
Lead
finish
(see 1.2.5)
/
\/
Drawing number
1.2.1 RHA designator. Device classes Q and V RHA marked devices meet the MIL-PRF-38535 specified RHA levels and are
marked with the appropriate RHA designator. Device class M RHA marked devices meet the MIL-PRF-38535, appendix A
specified RHA levels and are marked with the appropriate RHA designator. A dash (-) indicates a non-RHA device.
1.2.2 Device type(s). The device type(s) identify the circuit function as follows:
Device type
Generic number
01
Circuit function
AT7908E
Can ASIC space application
1.2.3 Device class designator. The device class designator is a single letter identifying the product assurance level as
follows:
Device class
Device requirements documentation
M
Vendor self-certification to the requirements for MIL-STD-883 compliant, nonJAN class level B microcircuits in accordance with MIL-PRF-38535, appendix A
Q or V
Certification and qualification to MIL-PRF-38535
1.2.4 Case outline(s). The case outline(s) are as designated in MIL-STD-1835 and as follows:
Outline letter
X
Descriptive designator
See figure 1
Terminals
Package style
44
Multilayer ceramic package
1.2.5 Lead finish. The lead finish is as specified in MIL-PRF-38535 for device classes Q and V or MIL-PRF-38535,
appendix A for device class M.
STANDARD
MICROCIRCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43216-5000
DSCC FORM 2234
APR 97
SIZE
5962-03A06
A
REVISION LEVEL
SHEET
2
1.3 Absolute maximum ratings. 1/
Supply voltage range (VDD) ......................................................................... -0.5 V to 6.0 V 2/
Input voltage range (VIN) ........................................................................... -0.5 V to VDD + 0.5 V
Storage temperature range ........................................................................ -65oC to +150oC
Lead temperature ....................................................................................... +300oC
4/
Maximum junction temperature (TJ) ............................................................ +175oC
Maximum power dissipation (PD) ................................................................ 0.3 W
o
Thermal resistance, junction-to-case (θJC) .................................................. 5.1 C/W
3/
1.4 Recommended operating conditions.
Supply voltage range (VDD) ........................................................................ 4.5 V to 5.5 V
Ambient temperature (TA) ........................................................................... -55oC to 125oC
Storage conditions ..................................................................................... 30oC, 20 to 65% RH, dust free, original packing
2. APPLICABLE DOCUMENTS
2.1 Government specification, standards, and handbooks. The following specification, standards, and
handbooks form a part of this drawing to the extent specified herein. Unless otherwise specified, the issues of these documents
are those cited in the solicitation or contract.
DEPARTMENT OF DEFENSE SPECIFICATION
MIL-PRF-38535 - Integrated Circuits, Manufacturing, General Specification for.
DEPARTMENT OF DEFENSE STANDARDS
MIL-STD-883 MIL-STD-1835 -
Test Method Standard Microcircuits.
Interface Standard Electronic Component Case Outlines.
DEPARTMENT OF DEFENSE HANDBOOKS
MIL-HDBK-103 MIL-HDBK-780 -
List of Standard Microcircuit Drawings.
Standard Microcircuit Drawings.
(Copies of these documents are available online at http://assist.daps.dla.mil/quicksearch/ or http://assist.daps.dla.mil or
from the Standardization Document Order Desk, 700 Robbins Avenue, Building 4D, Philadelphia, PA 19111-5094.)
2.2 Order of precedence. In the event of a conflict between the text of this drawing and the references cited herein, the text of
this drawing takes precedence. Nothing in this document, however, supersedes applicable laws and regulations unless a
specific exemption has been obtained.
3. REQUIREMENTS
3.1 Item requirements. The individual item requirements for device classes Q and V shall be in accordance with
MIL-PRF-38535 and as specified herein or as modified in the device manufacturer's Quality Management (QM) plan. The
modification in the QM plan shall not affect the form, fit, or function as described herein. The individual item requirements for
device class M shall be in accordance with MIL-PRF-38535, appendix A for non-JAN class level B devices and as specified
herein.
_______
1/
2/
3/
4/
Stresses above the absolute maximum rating may cause permanent damage to the device. Extended operation at the
maximum levels may degrade performance and affect reliability.
All voltages referenced to ground unless otherwise specified.
VDD + 0.5 V shall not exceed 6.0 V.
Duration 10 second maximum at a distance not less than 1.6 mm.
STANDARD
MICROCIRCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43216-5000
DSCC FORM 2234
APR 97
SIZE
5962-03A06
A
REVISION LEVEL
A
SHEET
3
3.2 Design, construction, and physical dimensions. The design, construction, and physical dimensions shall be as specified in
MIL-PRF-38535 and herein for device classes Q and V or MIL-PRF-38535, appendix A and herein for device class M.
3.2.1 Case outline The case outline shall be in accordance with 1.2.4 herein and figure 1.
3.2.2 Terminal connections. The terminal connections shall be as specified on figure 2.
3.2.3 Block or logic diagram. The block or logic diagram shall be as specified on figure 3.
3.2.4 Timing waveforms. The timing waveforms shall be specified on figure 4.
3.3 Electrical performance characteristics and postirradiation parameter limits. Unless otherwise specified herein, the
electrical performance characteristics and postirradiation parameter limits are as specified in table I and shall apply over the full
ambient operating temperature range.
3.4 Electrical test requirements. The electrical test requirements shall be the subgroups specified in table II. The electrical
tests for each subgroup are defined in table I.
3.5 Marking. The part shall be marked with the PIN listed in 1.2 herein. In addition, the manufacturer's PIN may also be
marked. For packages where marking of the entire SMD PIN number is not feasible due to space limitations, the manufacturer
has the option of not marking the "5962-" on the device. For RHA product using this option, the RHA designator shall still be
marked. Marking for device classes Q and V shall be in accordance with MIL-PRF-38535. Marking for device class M shall be
in accordance with MIL-PRF-38535, appendix A.
3.5.1 Certification/compliance mark. The certification mark for device classes Q and V shall be a "QML" or "Q" as required in
MIL-PRF-38535. The compliance mark for device class M shall be a "C" as required in MIL-PRF-38535, appendix A.
3.6 Certificate of compliance. For device classes Q and V, a certificate of compliance shall be required from a QML-38535
listed manufacturer in order to supply to the requirements of this drawing (see 6.6.1 herein). For device class M, a certificate of
compliance shall be required from a manufacturer in order to be listed as an approved source of supply in MIL-HDBK-103 (see
6.6.2 herein). The certificate of compliance submitted to DSCC-VA prior to listing as an approved source of supply for this
drawing shall affirm that the manufacturer's product meets, for device classes Q and V, the requirements of MIL-PRF-38535 and
herein or for device class M, the requirements of MIL-PRF-38535, appendix A and herein.
3.7 Certificate of conformance. A certificate of conformance as required for device classes Q and V in MIL-PRF-38535 or for
device class M in MIL-PRF-38535, appendix A shall be provided with each lot of microcircuits delivered to this drawing.
3.8 Notification of change for device class M. For device class M, notification to DSCC-VA of change of product (see 6.2
herein) involving devices acquired to this drawing is required for any change that affects this drawing.
3.9 Verification and review for device class M. For device class M, DSCC, DSCC's agent, and the acquiring activity retain the
option to review the manufacturer's facility and applicable required documentation. Offshore documentation shall be made
available onshore at the option of the reviewer.
3.10 Microcircuit group assignment for device class M. Device class M devices covered by this drawing shall be in
microcircuit group number 123 (see MIL-PRF-38535, appendix A).
STANDARD
MICROCIRCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43216-5000
DSCC FORM 2234
APR 97
SIZE
5962-03A06
A
REVISION LEVEL
A
SHEET
4
TABLE I. Electrical performance characteristics.
Test
Conditions
- 55°C ≤ TA ≤ +125°C
Symbol
Group A
Subgroups
unless otherwise specified
Limits
Units
Min.
Max.
-0.2
Input clamp voltage to ground 1/
VIC
IOH = -300 µA
1, 2, 3
-1.2
Low level input current
IIL
VIN = GND, VDD = 5.5 V
1, 2, 3
-5
µA
2/
V
Low level input current, pull-up
2/
IILPU
VIN = GND, VDD = 5.5 V
1, 2, 3
-100
µA
Low level input current, pull-down
2/
ILLPD
VIN = GND, VDD = 5.5 V
1, 2, 3
-5
µA
IIH
VIN = VDD = 5.5 V
1, 2, 3
5
µA
2/
IIHPU
VIN = VDD = 5.5 V
1, 2, 3
5
µA
High level input current, pull-down 2/
IIHPD
VIN = VDD = 5.5 V
1, 2, 3
300
µA
Output leakage low current
IOZL
VOUT = GND, Outputs disabled
1, 2, 3
IOZHPD
VOUT = VDD, Outputs disabled
1, 2, 3
IOZLPU
VOUT = GND, Outputs disabled
1, 2, 3
IOZH
VOUT = VDD, Outputs disabled
1, 2, 3
5
Low level output voltage, BOUT12 2/
VOL1
VDD = 4.5 V, IOL = +12 mA
1, 2, 3
0.4
V
Low level output voltage, BOUT6
2/
VOL2
VDD = 4.5 V, IOL = +6 mA
1, 2, 3
0.4
V
Low level output voltage, BOUT3
2/
VOL3
VDD = 4.5 V, IOL = +3 mA
1, 2, 3
0.4
V
High level output voltage, BOUT12 2/
VOH1
VDD = 4.5 V, IOL = -12 mA
1, 2, 3
3.9
V
High level output voltage, BOUT6
2/
VOH2
VDD = 4.5 V, IOL = -6 mA
1, 2, 3
3.9
V
High level output voltage, BOUT3 2/
VOH3
VDD = 4.5 V, IOL = -3 mA
1, 2, 3
3.9
V
High level input current
2/
High level input current, pull-up
2/
Output leakage high current,
-5
µA
300
µA
pull-down output 2/
Output leakage low current,
-100
µA
pull-up output 2/
Output leakage high current
2/
µA
Low level input voltage
1/
VIL
Functional verification
1, 2, 3
High level input voltage
1/
VIH
Functional verification
1, 2, 3
CI
VDD = 0 V
4
15
pF
CIO
VDD = 0 V
4
15
pF
IDDSBA
VDA = 5.5V
1, 2, 3
50
µA
IDDOPA
VDA = 5.5V
4, 5, 6
25
mA
VDB = 5.5V
4, 5, 6
10
mA
Input capacitance
3/
Output capacitance 3/
Supply current stand by for array
2/
Supply current operating for array 2/
Supply current operating for buffer 2/
IDDOPB
0.3 VDD
0.7 VDD
V
V
See notes at end of table.
STANDARD
MICROCIRCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43216-5000
DSCC FORM 2234
APR 97
SIZE
5962-03A06
A
REVISION LEVEL
SHEET
5
TABLE I. Electrical performance characteristics - Continued.
Test
Symbol
Conditions
- 55°C ≤ TA ≤ +125°C
Group A
Subgroups
unless otherwise specified
Address valid to ALE low
2/
Units
Limits
Min.
Max.
TAVLL
VDD = 5V ±10%,
9, 10, 11
4
9, 10, 11
4
9, 10, 11
100
TLLAX
VSS = 0V,
ALE high time
TLHLL
Tclk = 100 ns
ALE low to RD low
TLLRL
9, 10, 11
200
TCHRL
9, 10, 11
100
Input data valid to WR High
TDVWH
9, 10, 11
300
Input data hold after WR high
TWHQX
9, 10, 11
10
WR pulse width
TWLWH
9, 10, 11
300
WR high to next ALE high
TWHLH
9, 10, 11
100
TWS
9, 10, 11
-3
WR hold time after clock
TWH
9, 10, 11
7
RD pulse width
TRLRH
9, 10, 11
RD low to data valid
TRLDV
9, 10, 11
6
82
Data float after RD High
TRHDZ
9, 10, 11
4
20
Address hold after ALE low
CS high to RD low
2/
2/
WR setup time before clock
2/
ns
300
Notes:
1. Forcing conditions of the functional test assure that these limits are met but they will not be individually recorded.
2. Read and record measurements in accordance with MIL-PRF-38535.
3. Tested at initial design and after major process changes, otherwise guaranteed.
STANDARD
MICROCIRCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43216-5000
DSCC FORM 2234
APR 97
SIZE
5962-03A06
A
REVISION LEVEL
SHEET
6
Case X
Millimeters
Symbol
A
Min
Max
Min
Max
2.67
4.95
.105
.195
A1
b1
Inches
1.65 NOM
0.33
.065 NOM
0.56
.013
.022
b2
0.55
0.88
.022
.035
c1
0.17
0.25
.007
.010
D/E
17.14
17.78
.675
.700
D1/E1
15.74
16.75
.620
.660
e
1.27 BSC
e2
16.00 BSC
L
.050 BSC
.630 BSC
0.12
.005
ND/NE
11
R
0.50
J
0.58
11
1.01
.020
.040
.023
FIGURE 1. Case outline.
STANDARD
MICROCIRCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43216-5000
DSCC FORM 2234
APR 97
SIZE
5962-03A06
A
REVISION LEVEL
SHEET
7
Case X
Pin number
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
Signal name
VDDA1
Addr[4]
Addr[5]
Addr[6]
Addr[7]
VSSB1
VDDB2
Cs
Mode
Ale
Wr
VSSA1
Rd
Sena
Test
Reset
VSSB2
VDDB3
Can_rx
Hasync
Xtalout
Xtalin
VDDA2
Int
Hatrig
Can_tx
VSSB3
VDDB4
Data[0]
Data[1]
Data[2]
Data[3]
VSSA2
Data[4]
Type
I
I
I
I
I
I
I
I
I
I
I
I
I
O
I/O
I
O
O
O
I/O
I/O
I/O
I/O
I/O
Note
Power for array
Input address (mode 1) or output address (mode 0)
Input address (mode 1) or output address (mode 0)
Input address (mode 1) or output address (mode 0)
Input address (mode 1) or output address (mode 0)
Ground for periphery
Power for periphery
Chip Select signal
Interface operational mode
Adress latch enable
Write signal
Ground for Array
Read signal
Scan enable
Input signal to increase testability
Reset signal
Ground for periphery
Power for periphery
RX signal
Output synchronization signal
Not connected
Output from internal oscillator
Input to internal oscillator or clock input from external oscillator
Power for array
Interrupt request
Output signal to trigger the message matching
TX signal
Ground for periphery
Power for periphery
Adress data bus
Adress data bus
Adress data bus
Adress data bus
Ground for Array
Adress data bus
FIGURE 2. Terminal connections.
STANDARD
MICROCIRCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43216-5000
DSCC FORM 2234
APR 97
SIZE
5962-03A06
A
REVISION LEVEL
A
SHEET
8
Pin number
Signal name
Type
Note
36
Data[5]
I/O
Adress data bus
37
Data[6]
I/O
Adress data bus
38
Data[7]
I/O
Adress data bus
39
VSSB4
Ground for periphery
40
VDDB1
Power for periphery
41
Addr[0]
I
Input address (mode 1) or output address (mode 0)
42
Addr[1]
I
Input address (mode 1) or output address (mode 0)
43
Addr[2]
I
Input address (mode 1) or output address (mode 0)
44
Addr[3]
I
Input address (mode 1) or output address (mode 0)
Notes:
1. Mode : Input pin to select operational mode of interface:
mode = 0 : 8 bit data bus multiplexed with lowest 8-bit address(register mapped between 8000Hex and 804Chex)
mode = 1 : 8 bit not multiplexed address data bus ( register mapped between 00 Hex and 4C Hex)
2. VDDA1 = VDDA2 = VDDB1 = VDDB2 = VDDB3 = VDDB4 = 5 V
3. VSSA1 = VSSA2 = VSSB1 = VSSB2 = VSSB3 = VSSB4 = 0V
4. I = Input, O = Output
FIGURE 2. Terminal connections - Continued.
FIGURE 3. Block diagram.
STANDARD
MICROCIRCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43216-5000
DSCC FORM 2234
APR 97
SIZE
5962-03A06
A
REVISION LEVEL
A
SHEET
9
FIGURE 4. Timing waveforms.
STANDARD
MICROCIRCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43216-5000
DSCC FORM 2234
APR 97
SIZE
5962-03A06
A
REVISION LEVEL
A
SHEET
10
4. VERIFICATION
4.1 Sampling and inspection. For device classes Q and V, sampling and inspection procedures shall be in accordance with
MIL-PRF-38535 or as modified in the device manufacturer's Quality Management (QM) plan. The modification in the QM plan
shall not affect the form, fit, or function as described herein. For device class M, sampling and inspection procedures shall be in
accordance with MIL-PRF-38535, appendix A.
4.2 Screening. For device classes Q and V, screening shall be in accordance with MIL-PRF-38535, and shall be conducted
on all devices prior to qualification and technology conformance inspection. For device class M, screening shall be in
accordance with method 5004 of MIL-STD-883, and shall be conducted on all devices prior to quality conformance inspection.
4.2.1 Additional criteria for device class M.
a.
Burn-in test, method 1015 of MIL-STD-883.
(1) Test condition A, B, C, D or E. The test circuit shall be maintained by the manufacturer under document revision
level control and shall be made available to the preparing or acquiring activity upon request. The test circuit shall
specify the inputs, outputs, biases, and power dissipation, as applicable, in accordance with the intent specified in
method 1015.
(2) TA = +125°C, minimum.
b.
Interim and final electrical test parameters shall be as specified in table II herein.
4.2.2 Additional criteria for device classes Q and V.
a.
The burn-in test duration, test condition and test temperature, or approved alternatives shall be as specified in the
device manufacturer's QM plan in accordance with MIL-PRF-38535. The burn-in test circuit shall be maintained under
document revision level control of the device manufacturer's Technology Review Board (TRB) in accordance with MILPRF-38535 and shall be made available to the acquiring or preparing activity upon request. The test circuit shall
specify the inputs, outputs, biases, and power dissipation, as applicable, in accordance with the intent specified in
method 1015 of MIL-STD-883.
b.
Interim and final electrical test parameters shall be as specified in table II herein.
c.
Additional screening for device class V beyond the requirements of device class Q shall be as specified in
MIL-PRF-38535, appendix B.
4.3 Qualification inspection for device classes Q and V. Qualification inspection for device classes Q and V shall be in
accordance with MIL-PRF-38535. Inspections to be performed shall be those specified in MIL-PRF-38535 and herein for groups
A, B, C, D, and E inspections (see 4.4.1 through 4.4.4).
4.4 Conformance inspection. Technology conformance inspection for classes Q and V shall be in accordance with
MIL-PRF-38535 including groups A, B, C, D, and E inspections and as specified herein. Quality conformance inspection for
device class M shall be in accordance with MIL-PRF-38535, appendix A and as specified herein. Inspections to be performed
for device class M shall be those specified in method 5005 of MIL-STD-883 and herein for groups A, B, C, D, and E inspections
(see 4.4.1 through 4.4.4).
4.4.1 Group A inspection.
a.
Tests shall be as specified in table II herein.
b.
For device class M, subgroups 7 and 8 tests shall be sufficient to verify the functionality of the device. For device
classes Q and V, subgroups 7 and 8 shall include verifying the functionality of the device; these tests shall have been
fault graded in accordance with MIL-STD-883, test method 5012.
4.4.2 Group C inspection. The group C inspection end-point electrical parameters shall be as specified in table II herein.
STANDARD
MICROCIRCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43216-5000
DSCC FORM 2234
APR 97
SIZE
5962-03A06
A
REVISION LEVEL
A
SHEET
11
TABLE II. Electrical test requirements.
Test requirements
Interim electrical
parameters (see 4.2)
Final electrical
parameters (see 4.2)
Group A test
requirements (see 4.4)
Group C end-point electrical
parameters (see 4.4)
Group D end-point electrical
parameters (see 4.4)
Group E end-point electrical
parameters (see 4.4)
1.
2.
3.
Subgroups
(in accordance with
MIL-PRF-38535, table III)
Device
Device
class Q
class V
1, 7, 9
1, 7, 9 ∆
1/
1, 2, 3, 7, 8, 9,
1, 2, 3, 7, 8,
10, 11 2/
9, 10, 11 3/
Subgroups
(in accordance with
MIL-STD-883, method 5005, table I)
Device
class M
1, 7, 9
1, 2, 3, 7, 8, 9, 10, 11 2/
1, 2, 3, 4, 7, 8, 9, 10, 11
1, 2, 3, 4, 7, 8,
9, 10, 11
1, 2, 3, 4, 7,
8, 9, 10, 11
1, 7, 9
1, 2, 3, 7, 8, 9,
10, 11
1, 2, 3, 7, 8,
9, 10, 11
1, 7, 9
1, 7, 9
1, 7, 9
1, 7, 9
1, 7, 9
1, 7, 9
∆ indicates delta limits (see table IIB) shall be required where specified and the delta values shall be
computed with reference to previous interim electrical parameters. For device class V, performance of
delta limits shall be specified by the manufacturer’s QM plan.
PDA applies to subgroups 1.
PDA applies to subgroups 1 and 7.
TABLE IIB. Delta limits at 25°C
Parameters 1/
ICCSBA
All device types
VOL/VOH
± 0.1 V
± 5 µA
IOZL/IOZH
± 0.1 µA
IIL/IIH
± 0.1 µA
1. The above parameters shall be recorded before and after burn-in and life test to determine the drift.
4.4.2.1 Additional criteria for device class M. Steady-state life test conditions, method 1005 of MIL-STD-883:
a.
Test condition A, B, C, D or E. The test circuit shall be maintained by the manufacturer under document revision level
control and shall be made available to the preparing or acquiring activity upon request. The test circuit shall specify the
inputs, outputs, biases, and power dissipation, as applicable, in accordance with the intent specified in method 1005 of
MIL-STD-883.
b.
TA = +125°C, minimum.
c.
Test duration: 1,000 hours, except as permitted by method 1005 of MIL-STD-883.
4.4.2.2 Additional criteria for device classes Q and V. The steady-state life test duration, test condition and test
temperature, or approved alternatives shall be as specified in the device manufacturer's QM plan in accordance with MIL-PRF38535. The test circuit shall be maintained under document revision level control by the device manufacturer's TRB in
accordance with
MIL-PRF-38535 and shall be made available to the acquiring or preparing activity upon request. The test circuit shall specify the
inputs, outputs, biases, and power dissipation, as applicable, in accordance with the intent specified in method 1005 of
MILSTD-883.
STANDARD
MICROCIRCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43216-5000
DSCC FORM 2234
APR 97
SIZE
5962-03A06
A
REVISION LEVEL
A
SHEET
12
4.4.3 Group D inspection. The group D inspection end-point electrical parameters shall be as specified in table II herein.
4.4.4 Group E inspection. Group E inspection is required only for parts intended to be marked as radiation hardness assured
(see 3.5 herein).
a.
End-point electrical parameters shall be as specified in table II herein.
b.
For device classes Q and V, the devices or test vehicle shall be subjected to radiation hardness assured tests as
specified in MIL-PRF-38535 for the RHA level being tested. For device class M, the devices shall be subjected to
radiation hardness assured tests as specified in MIL-PRF-38535, appendix A for the RHA level being tested. All device
classes must meet the postirradiation end-point electrical parameter limits as defined in table I at
TA = +25°C ±5°C, after exposure, to the subgroups specified in table II herein.
c.
When specified in the purchase order or contract, a copy of the RHA delta limits shall be supplied.
5. PACKAGING
5.1 Packaging requirements. The requirements for packaging shall be in accordance with MIL-PRF-38535 for device classes
Q and V or MIL-PRF-38535, appendix A for device class M.
6. NOTES
6.1 Intended use. Microcircuits conforming to this drawing are intended for use for Government microcircuit applications
(original equipment), design applications, and logistics purposes.
6.1.1 Replaceability. Microcircuits covered by this drawing will replace the same generic device covered by a contractor
prepared specification or drawing.
6.1.2 Substitutability. Device class Q devices will replace device class M devices.
6.2 Configuration control of SMD's. All proposed changes to existing SMD's will be coordinated with the users of record for
the individual documents. This coordination will be accomplished using DD Form 1692, Engineering Change Proposal.
6.3 Record of users. Military and industrial users should inform Defense Supply Center Columbus when a system application
requires configuration control and which SMD's are applicable to that system. DSCC will maintain a record of users and
this list will be used for coordination and distribution of changes to the drawings. Users of drawings covering
microelectronic devices (FSC 5962) should contact DSCC-VA, telephone (614) 692-0544.
6.4 Comments. Comments on this drawing should be directed to DSCC-VA , Columbus, Ohio 43216-5000, or telephone
(614) 692-0547.
6.5 Abbreviations, symbols, and definitions. The abbreviations, symbols, and definitions used herein are defined in
MIL-PRF-38535 and MIL-HDBK-1331.
6.6 Sources of supply.
6.6.1 Sources of supply for device classes Q and V. Sources of supply for device classes Q and V are listed in QML-38535.
The vendors listed in QML-38535 have submitted a certificate of compliance (see 3.6 herein) to DSCC-VA and have agreed to
this drawing.
6.6.2 Approved sources of supply for device class M. Approved sources of supply for class M are listed in MIL-HDBK-103.
The vendors listed in MIL-HDBK-103 have agreed to this drawing and a certificate of compliance (see 3.6 herein) has been
submitted to and accepted by DSCC-VA.
STANDARD
MICROCIRCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43216-5000
DSCC FORM 2234
APR 97
SIZE
5962-03A06
A
REVISION LEVEL
A
SHEET
13
STANDARD MICROCIRCUIT DRAWING BULLETIN
DATE: 07-03-06
Approved sources of supply for SMD 5962-03A06 are listed below for immediate acquisition information only and
shall be added to MIL-HDBK-103 and QML-38535 during the next revision. MIL-HDBK-103 and QML-38535 will be
revised to include the addition or deletion of sources. The vendors listed below have agreed to this drawing and a
certificate of compliance has been submitted to and accepted by DSCC-VA. This bulletin is superseded by the next
dated revision of MIL-HDBK-103 and QML-38535.
Standard
microcircuit drawing
PIN 1/
5962-03A0601QXC
5962-03A0601VXC
Vendor
CAGE
number
F7400
F7400
Vendor
similar
PIN 2/
AT7908EJLMQ
AT7908EJLSV
1/ The lead finish shown for each PIN representing
a hermetic package is the most readily available
from the manufacturer listed for that part. If the
desired lead finish is not listed contact the vendor
to determine its availability.
2/ Caution. Do not use this number for item
acquisition. Items acquired to this number may not
satisfy the performance requirements of this drawing.
Vendor CAGE
number
F7400
Vendor name
and address
Atmel Nantes SA
BP 70602
44306 Nantes Cedex 3
France
The information contained herein is disseminated for convenience only and the
Government assumes no liability whatsoever for any inaccuracies in the
information bulletin.