Datasheet Uninterruptible Power Supplies Solutions NEW Weidmuller‘s uninterruptible power supply solutions reliably protect 24 V DC applications from voltage drop-outs and sags, such as those that could occur as a result of incoming power fault. These product solutions play a key role in increasing up time and reliability. The buffer module is the perfect solution for bridging shortterm power supply failures or dips of up to 100 ms. The capacitor-based technology enables maintenance-free operation for up to 10 years, depending upon the application. The UPS control unit, together with the accompanying battery module and the power supply, form a complete and scalable DC UPS system with support times ranging from minutes to hours. Battery Module Buffer Module UPS Control Unit The modular construction allows for the overall load to be distributed into safe areas and standard load circuits, giving the user flexibility in their designs. A huge variety of configurations are available by selecting different size control units, batteries, power supplies, and buffer modules to suit your particular application. For example, a remote input can be used to block battery operation. Multiple signal outputs show status and operation of the UPS. % Weidmuller, Canada 10 Spy Court Markham, Ontario L3R 5H6 Telephone: (800) 268-4080 Facsimile: (877) 300-5635 Email: [email protected] Website: www.weidmuller.ca Weidmuller, Mexico Blvd. Hermanos Serdán 698, Col. San Rafael Oriente Puebla, Puebla, Mexico C.P. 72029 Telephone: 01 222 2686267 Facsimile: 01 222 2686219 Email: [email protected] Website: www.weidmuller.com.mx { \u Weidmuller, United States 821 Southlake Blvd. Richmond, Virginia 23236 Telephone: (800) 849-9343 Facsimile: (804) 379-2593 Email: [email protected] Website: www.weidmuller.com Uninterruptible Power Supplies Solutions Can your facility afford to experience a power failure? Allow us to connect you so that you are safe from failure and downtime. Let’s connect. It is critical to safeguard a facility‘s power supply in the event of an outage. You cannot do without the important signals from the field, which serve to control the entire process. In addition, you also need to monitor a whole range of functions and performance parameters for your facility. Our highly modular power supply concept will support you in the practical fulfilment of all your requirements. At the same time, we will also familiarize ourselves with your future requirements and provide you with an individual, tailor-made solution, with components that are precisely aligned to work with one another. For a continual, lasting power supply and clean control voltage, we use redundant circuits, selective short-circuit solutions, battery reservoirs and DC/DC converters. And because lightning and power surges can put an uninterrupted power supply in a production facility at risk, we also provide lightning and overvoltage protection. The VPU series provides unrestricted operation of power supplies and automation devices such as sensors, actuators and control units. The subsequent availability of the power supply means that all devices will restart in a controlled manner. Let’s connect. UPS with battery module Remote disconnection Interlock Mains PS AC DC +24 V DC Non-safe load 2 + – Weidmuller Power Supplies •Used to save space in automation technology • Individual modulation of the output power • Up to 5 devices can be switched directly, in parallel • Optional diode modules with fault signalling • Expanded temperature range –25 °C to 70 °C UPS control unit • Different status relays for status monitoring •Direct switchover to battery operation in the event of malfunction • Automatic reconnection to load when power recovers •Long battery life due to integrated deep discharge protection • Optimised charging feature UPS with buffer module Relay and transistor ouput Relay and transistor outputs CP DC UPS 24V UPS control unit + +24 V DC – Safe load Battery module CP A Battery 24 V DC Mains PS AC DC +24 V DC Non-safe load + – CP DC BUFFER 24V 20A + Buffer module +24 V DC Safe load – Uninterruptible Power Supplies Solutions UPS control unit •Two 24 V models in 10 A/20 A and 40 A •Temperature-compensated charging feature for long battery life •Integrated battery diagnostics including continuous availability test •Status relay and additional transistor outputs for remote monitoring •Convenient LED displays for easy error analysis % Technical data Indication Status relay ( max.load 30 V AC/DC 0.1 A) Transistor outputs (24 to 27 V DC max. load 150 mA) LED status indicator General technical data Ambient temperature (operational) Storage temperature Max. perm. air humidity Protection degree Class of protection Pollution severity level Overvoltage category Insulation voltage input/output to housing/ground MTBF Protection against reverse voltages from the load Parallel connection option Housing version Mounting position, installation notice Overload protection Short-circuit protection EMC / shock / vibration Interference emission Interference immunity tests Resistance against vibration and shock Electrical safety (applied standards) Electrical equipment of machines Safety transformers for switch-mode power supplies Machinery with electronic equipment Extra-low voltage protection Block diagram Interlock – 1 Interlock + 2 Temperature 6 Sensor 7 { \u Fault (alarm), battery operation (buff.), charging (charg.) Fault (alarm), battery operation (buff.), charging (charg.) Three-colour LED: battery capacities > 85 % green, > 40 % yellow, > 20 % red, < 20 % red (flashing) Green/yellow LED: normal / buffering Yellow/red LED: temperature alarm / alarm Yellow/red LED: switch-off / battery fault –25 °C…+70 °C –40 °C…+85 °C 5…95 % IP 20 3 2 III 1300 V DC 1 min (typetest) > 500,000 hours acc. to IEC 1709 32…34 V DC Yes, only with diode module for redundancy Metal, corrosion resistant Horizontal on mounting rail TS 35, 50 mm above and below Space for free movement of air Yes Yes Acc. to EN55022 Class B Acc.to EN61000-4-2 (ESD), EN61000-4-3 and EN61000-4-8 (fields), EN61000-4-4 (burst), EN61000-4-5 (surge), EN610004-6 (conducted), EN61000-4-11 (dips) Acc.to IEC60954 Vibration: 2.3 g, Acc.to IEC60068-2-31 shock: 30 g in all directions Acc. to EN60204 Acc. to EN61558-2-17 Acc. to EN50178 / VDE0160 SELV acc. to EN60950, PLEV acc. to EN60204 Cabling 3 Alarm Battery Capacity Normal / Buffering Alarm Cut-off / Bat.Failure Selector switches – Buffer time – Battery size – DIP switch – 10/20A (only1370050010) 4 Buffering 5 Charging 11 14 Alarm 12 21 24 Buffering 22 31 34 Charging 32 + µC + 24V DC Input Charger – 24V DC Output – Bat – + + Unbuffered DC Load – + – + + – 24V DC Output Power Supply Buffered DC Load – + – + – + – + Input Battery Output + – DC UPS Battery Module CP DC UPS 24V DC 20A/10A CP DC UPS 24V DC 40A CP A BATTERY 24V DC .. Ah 1 2 3 4 5 11 21 31 6 7 12 14 22 24 32 34 7 6 Temperature Sensor 3 Uninterruptible Power Supplies Solutions UPS control unit CP DC UPS 24V 20A/10A CP DC UPS 24V 40A Technical data Input Rated input voltage Input voltage range Nominal input current (up to 60 °C) Input current, max. (to 45 °C) Input fuse Standby current (without battery) Standby current (with fully charged battery) Reverse polarity protection Output Rated output voltage Output voltage, normal operation (Imax) Output voltage, battery operation (Imax) Rated output current (up to 60 °C) Continuous output current (up to 70 °C), derating from 60 °C Continuous output current (up to 45 °C) Power Boost@24 V DC, 60 °C Integrated battery charger Charging voltage (temperature compensated) Temperature coefficient Charging current Battery availability test Battery module Rated voltage Storage medium (AGM battery) Parallel connection option Operating elements and control inputs Output current selector switch Battery in Ah selector switch Buffer times in minutes selector switch DIP switch Remote disconnection (Interlock) Temperature sensor connection General data Buffer times Efficiency Power loss Depth x width x height Weight Approvals Connection data Conductor connection system Wire cross-section, rigid mm² (min./max.) Wire cross-section, flexible mm² (min./max.) Wire cross-section, AWG/kcmil (min./max.) Stripping length (mm) Tightening torque range (NM) Ordering data Note 4 24 V DC 20…30 V DC ≤ 13 A (for 10 A) │≤ 23 A (for 20 A) ≤ 15 A (for 10 A)│≤ 27 A (for 20 A) Yes, 30 A max. 200 mA max. 0.5 A Yes 24 V DC 20…30 V DC ≤ 43 A ≤ 51 A Yes, 60 A max. 200 mA max. 0.5 A Yes 24 V DC Vo = Vin – 0.2 V Vo = Vin – 0.3 V 10 A / 20 A 7.5 A / 15 A 24 V DC Vo = Vin – 0.2 V Vo = Vin – 0.3 V 40 A 24 A 12 A / 24 A 12 A / 24 A for 1 min, ED = 5 % 48 A 48 A for 1 min, ED = 5 % 27, 48 V @ 20 °C – 48 mV / °C 0.15 CA Yes, each minute 27, 48 V @ 20 °C – 48 mV / °C 0.15 CA Yes, each minute 24 V DC 1.3 Ah, 3.4 Ah, 7.2 Ah, 12 Ah, 17 Ah (selectable, with rotary switch) Yes, max. 2 24 V DC 3.4 Ah, 7.2 Ah, 12 Ah, 17 Ah (selectable, with rotary switch) Yes, max. 2 10 A / 20 A 1.3 / 3.4 / 7.2 / 12 / 17 / No Battery / Service 0.5 / 1 / 3 / 5 / 10 / 20 / 30 / 45 / ∞ / ∞ w/0 Inversion of the transistor outputs; operation without temperature sensor Yes Yes, for NTC 100 KΩ No 3.4 / 7.2 / 12 / 17 / No Battery / Service 0.5 / 1 / 3 / 5 / 10 / 20 / 30 / 45 / ∞ / ∞ w/0 Inversion of the transistor outputs; operation without temperature sensor Yes Yes, for NTC 100 KΩ Depending on the connected battery (adjustable) ≥ 98 % Normal operation, battery charged ≥ 96 % Normal operation, battery charging ≥ 98 % Battery operation <10 W 150 / 66 / 130 mm 0.98 kg Depending on the connected battery (adjustable) ≥ 98 % Normal operation, battery charged ≥ 96 % Normal operation, battery charging ≥ 98 % Battery operation <10 W 150 / 66 / 130 mm 1.0 kg CE, TÜV, cURus, cULus; GL Input/output/battery Screw connection 0.5/16 0.5/16 26/6 10 1.2…1.5 CE, TÜV, cURus, cULus; GL Input/output/battery Screw connection 0.5/16 0.5/16 26/6 10 1.2…1.5 Signal 0.5/6 0.5/4 26/12 8 0.5…0.6 Type Qty. Part No. CP DC UPS 24 V 20 A/10 A 1 1370050010 Standard with Metal TS-35 DIN-Rail Mounting Foot. See Page 8 for additional mounting options. Signal 0.5/6 0.5/4 26/12 8 0.5…0.6 Type Qty. Part No. CP DC UPS 24 V 40 A 1 1370040010 Standard with Metal TS-35 DIN-Rail Mounting Foot. See Page 8 for additional mounting options. Uninterruptible Power Supplies Solutions Battery modules CP A BATTERY 24V DC1.3 Ah CP A BATTERY 24V DC 3.4 Ah •Maintenance-free lead-acid batteries from 3.4 Ah to 17 Ah •Integrated temperature sensor for optimal battery charging •Integrated fuse for reliable activation •Capacity up to 40 A / 30 min or 1 A / 30 hrs •Robust metal housing for wall mounting % %\ Technical data \ Rated voltage Nominal capacity Max. charging current at 0.15 CA Fuse (ATO flat blade fuse max. 80 V DC) Buffer time 24 V DC 1.3 Ah 0.2 A 15 A 11.3 min @ 10 A 5 min @ 20 A 24 V DC 3.4 Ah 0.51 A 25 A 11.3 min @ 10 A 5 min @ 20 A Max. output current Parallel connection option Series switching capability Temperature sensor General data Battery type (maintenance-free battery) 15 A Yes, max. 2 No NTC 100 kΩ 25 A Yes, max. 2 No NTC 100 kΩ Valve Regulated Lead Acid (VRLA)- Absorbed Glass Mat (AGM) UP-RW1220P 6…9 @ 20 °C 0°...+40 °C –15°…+40 °C 9 5…95 % III IP 20 Valve Regulated Lead Acid (VRLA)- Absorbed Glass Mat (AGM) UP-RW1220P 6…9 @ 20 °C 0°...+40 °C –15°…+40 °C 9 5…95 % III IP 20 2.3 g / 2.3 g 0.7 g / 0.7 g 30 g 30 g 124 / 52 / 148 mm 1.5 kg CE; GL, UL 508 Input/output/battery Pluggable 0.2/6 0.25/6 30/12 0.5 126 / 108 / 144 mm 3.6 kg CE, TÜV; GL, UL 508 Input/output/battery Pluggable 0.2/6 0.25/6 24/10 0.5…0.6 Battery type Panasonic Lifetime in years (application-dependent) Ambient temperature Storage temperature Latest commissioning in months Max. perm. air humidity Class of protection Protection degree Vibration mounting rail assembly/wall mounting acc. to IEC 68-2-6 Shock mounting rail assembly/wall mounting acc. to IEC 68-2-27 Depth x width x height Weight Approvals Connection data (input/output, signal) Screw connection Wire cross-section, rigid mm² (min./max.) Wire cross-section, flexible mm² (min./max.) Wire cross-section, AWG/kcmil (min./max.) Tightening torque range (Nm) Ordering data Note Signal 0.2/4 0.2/4 30/12 0.2…0.25 Type Qty. Part No. CP A BATTERY 24V DC1.3 Ah 1 1406930000 Standard with Metal TS-35 DIN-Rail Mounting Foot. Can also be surface mounted. See Page 8 for additional mounting options. Signal 0.2/1.5 0.2/1.5 28/16 0.2…0.25 Type Qty. Part No. CP A BATTERY 24V DC 3.4 Ah 1 1251070000 Standard with Metal TS-35 DIN-Rail Mounting Foot. Can also be surface mounted. See Page 8 for additional mounting options. Sensor 1 2 3 4 NTC PE 5 Uninterruptible Power Supplies Solutions Battery modules •Maintenance-free lead-acid batteries from 3.4 Ah to 17 Ah •Integrated temperature sensor for optimal battery charging •Integrated fuse for reliable activation •Capacity up to 40 A / 30 min or 1 A / 30 hrs •Robust metal housing for wall mounting CP A BATTERY 24V DC 12 Ah CP A BATTERY 24V DC 7.2 Ah % \ % CP A BATTERY 24V DC 17 Ah \ % \ Technical data Rated voltage Nominal capacity Max. charging current at 0.15 CA Fuse (ATO flat blade fuse max. 80 V DC) Buffer time Max. output current Parallel connection option Series switching capability Temperature sensor General data Battery type (maintenance-free battery) Battery type Panasonic Lifetime in years (application-dependent) Ambient temperature Storage temperature Latest commissioning in months Max. perm. air humidity Class of protection Protection degree Vibration mounting rail assembly/wall mounting acc. to IEC 68-2-6 Shock mounting rail assembly/wall mounting acc. to IEC 68-2-27 Depth x width x height Weight Approvals Connection data (input/output, signal) Screw connection Wire cross-section, rigid mm² (min./max.) Wire cross-section, flexible mm² (min./max.) Wire cross-section, AWG/kcmil (min./max.) Tightening torque range (Nm) Ordering data Note 24 V DC 7.2 Ah 1.8 A 2 x 25 A 26.5 min @ 10 A 11.5 min @ 20 A 5 min @ 30 A 50 A Yes, max. 2 No NTC 100 kΩ 24 V DC 12 Ah 1.8 A 2 x 25 A 51 min @ 10 A 22.7 min @ 20 A 9.2 min @ 30 A 50 A Yes, max. 2 No NTC 100 kΩ 24 V DC 17 Ah 2.55 A 2 x 25 A 81 min @ 10 A 34.2 min @ 20 A 13.5 min @ 30 A 50 A Yes, max. 2 No NTC 100 kΩ Valve Regulated Lead Acid (VRLA)Absorbed Glass Mat (AGM) LC-R127R2PG Valve Regulated Lead Acid (VRLA)Absorbed Glass Mat (AGM) LC-RA1212PG Valve Regulated Lead Acid (VRLA)Absorbed Glass Mat (AGM) LC-XD1217APG 6…9 @ 20 °C 6…9 @ 20 °C 10…12 @ 20 °C 0°...+40 °C –15°…+40 °C 9 5…95 % III IP 20 0°...+40 °C –15°…+40 °C 9 5…95 % III IP 20 0°...+40 °C –15°…+40 °C 9 5…95 % III IP 20 – / 0.7 g – / 0.7 g – / 0.7 g 30 g 30 g 30 g 126 / 162 / 155 mm 5.9 kg CE, TÜV; GL, UL 508 126 / 229 / 155 mm 9.2 kg CE, TÜV; GL, UL 508 160 / 232 / 178 mm 13.4 kg CE, TÜV; GL, UL 508 Input/output/battery Pluggable 0.2/6 0.25/6 24/10 0.5…0.6 Signal Input/output/battery 0.2/1.5 0.2/1.5 28/16 0.2…0.25 Pluggable 0.2/6 0.25/6 24/10 0.5…0.6 Type Qty. Part No. CP A BATTERY 1 1251080000 24V DC 7.2 Ah Surface mount only. Type Qty. CP A BATTERY 1 24V DC 12 Ah Surface mount only. Signal Input/output/battery Signal 0.2/1.5 0.2/1.5 28/16 0.2…0.25 Pluggable 0.2/6 0.25/6 24/10 0.5…0.6 0.2/1.5 0.2/1.5 28/16 0.2…0.25 Part No. 1251090000 Buffer timesn [min] Buffer times-output current curve 1000 Type Qty. Part No. CP A BATTERY 1 1251110000 24V DC 17 Ah Surface mount only. CP A Battery 24 V DC 12 Ah CP A Battery 24 V DC 17 Ah 100 10 CP A Battery 24 V DC 1.3 Ah CP A Battery 24 V DC 3.4 Ah 1 6 CP A Battery 24 V DC 7.2 Ah 0.1 1 10 100 Output current [A] Uninterruptible Power Supplies Solutions Buffer modules CP DC Buffer 24V 20A •Maintenance-free UPS on capacitor basis with a capacity to support 20 A / 260 ms •Parallel switching to increase the output current or support time •Status notification via LED and relay contact % {\ Technical data Input Input voltage Input current Max. approved input current Surge protection Output Output voltage Output current Parallel connection option Overload protection Surge protection Status relay (max. load) Display Operational General data Efficiency Insulation voltage input/output Storage medium Buffer times MTBF Ambient temperature Storage temperature Max. perm. air humidity Depth x width x height Standards applied EMC Weight Approvals Connection data Conductor connection system Wire cross-section mm² (nominal/min./max.) Ordering data 24 V DC (22.5…30 V DC) 0…22 A Max. 22 A 35 V DC suppressor diode 24 V DC 20 A, max. 22 A Yes, without diode module ≥ 22 A (Only at discharge) 31…34 V (Only at discharge) Input voltage OK (30 V AC/DC 2 A) Operational (24 V AC/DC 300 mA) LED green: ready 95 % 1 kV Internal condenser 260 ms at 20 A, 6 s at 1 A > 500,000 hours acc. to IEC 1709 –25 °C…+70 °C –40 °C…+85 °C 5…95 % 150 / 66 / 130 mm EN50178, EN60950 EN55011, EN55022, EN55024, EN61000-6-2,-3,-4 1.15 kg CE, TÜV, cURus, cULus Input Output Signal Screw connection 10/0.3/16 10/0.3/16 4/0.13/6 Type Qty. Part No. CP DC Buffer 24V 20A 1 1251220000 Plastic DIN-Rail Mounting Foot. See Page 8 for additional mounting options. Note Block diagram Input + – Output + – Ready – Fail 7 Uninterruptible Power Supplies Solutions UPS control unit - Accessories Small metal foot Type MTA 30 MF Large metal foot Part No. 1251320000 Type MTA 45 MF Small wall mounting Type CP A WALLADAPTER 30 MM Part No. 1251310000 Blade type B Part No. 1461870000 Type CP A WALLADAPTER 45 MM 8 Large plastic foot Part No. 1168970000 Type MTA 45 BK Part No. 1962250000 Temperature probe Part No. 1461850000 Type CP DC UPS TF25 Cable length 2.5 m Part No. 1444540000 Large screwdriver Size/AF a 0.5 b 3 c 100 Part No. 9008380000 Markers Type SM 18/9.5 K MC NE WS Type MTA 30 BK Large wall mounting Small screwdriver Type SDIS 0.5X3.0X100 Small plastic foot Type SDIS 1.0X5.5X125 Blade type B Size/AF a 1 b 5.5 c 125 Part No. 9008410000 End bracket For DIN rail TS 35 Colour white Qty. 200 Part No. 1248580000 Polyamide with fibre glass, screwable Colour Torque Qty. Part No. WEW 35/1 SW black 1.2 Nm 50 1162600000 Subject to technical changes • 10/14 • LIT1404E