Datasheet connectPower DC/DC Converter Weidmuller’s new electrically isolated DC/DC Converter from the PRO-M series, optimized for machinery and providing a host of advantages, avoids critical earth loops. From an unregulated or distorted input voltage, it generates a stable, low-distortion output voltage. The DC/DC Converter is a versatile solution for all 24 VDC power supply applications. With its class III protection it’s also ideal for use in floating ground systems, such as battery backup systems found in marine technology. Integrated features such as an alarm output, monitoring the status of the 24V output voltage, and an LED that indicates DC OK status for the output voltage, provide clear visual aids making trouble shooting quick and easy and optimize machine up-time. • 24VDC voltage converter, 250W, 10A • Space saving 60mm width • Side-by-side mounting capability • Shock and vibration resistant metal mounting foot • > 91% efficiency • Integrated DC OK LED • Relay contact status indication • Integrated transistor output • Category III protection for floating ground systems • Power boost 12A @ 24VDC for 1 minute • Temperature range -25° C to +70° C • Global approvals: cURus, cULus, CE, TÜV, GL Weidmuller, Canada 10 Spy Court Markham, Ontario L3R 5H6 Telephone: (800) 268-4080 Facsimile: (877) 300-5635 Email: [email protected] Website: www.weidmuller.ca Weidmuller, Mexico Blvd. Hermanos Serdán 698, Col. San Rafael Oriente Puebla, Puebla, Mexico C.P. 72029 Telephone: 01 222 2686267 Facsimile: 01 222 2686219 Email: [email protected] Website: www.weidmuller.com.mx Weidmuller, United States 821 Southlake Blvd. Richmond, Virginia 23236 Telephone: (800) 849-9343 Facsimile: (804) 379-2593 Email: [email protected] Website: www.weidmuller.com connectPower DC/DC converter connectPower DC/DC converter DC voltage converter for preparation and potential isolation in 24 V DC systems • Overvoltage category III • Class III protection • Status of relay contact • DC OK transistor output % { \u Technical data Temperature derating 130 Pout [% Pn] 120 110 100 90 80 70 60 20 30 40 50 60 Ambient temperature [°C] 70 80 General technical specifications Output characteristic curve / current limit Earth discharge current Ambient temp. Operating / storage temperature Max. permitted humidity (operational) Protection degree Class of protection Contamination degree Insulation voltage Overvoltage category MTBF Protection against load reverse voltages Parallel capability (without diode module) Mountable side-by-side without gaps Housing version, metal Signal operations Mounting position, installation notice Metal clip-on foot EMC / shock / vibration Noise emission according to EN55022 Interference immunity tests, according to Limiting of mains voltage harmonic currents Resistance against vibration and shock Electrical safety (applied standards) Electrical equipment of machines Safety transformers for switched-mode power units Machinery with electronic equipment Safety extra-low voltage Protective separation / protection against electrical shock Protection against dangerous shock currents Accessories Diode module (for redundant power supply) Capacity module (for pulse triggering of circuit breakers) 2 IU / > 120 % IN < 0.005 mA –25 °C … +70 °C / –40 °C … +85 °C 5 %…95 % RH IP20 III 2 2.5 kV AC 1 min. / 1.5 kV AC 1 min. / 0.5 kV AC 1 min. III > 500,000 hrs. according to IEC 1709 (SN29500) 33…34 V DC Yes, max. 5 Yes Resistant to corrosion LED green / red Horizontal on TS35 DIN-rail, above and below 50 mm Clearance for air circulation, suitable for aligning without clearance gap For installation in rotating systems Yes Class B EN61000-4-2 (ESD), EN61000-4-3 and EN61000-4-8 (Fields), EN61000-4-4 (Burst), EN61000-4-5 (Surge), EN610004-6 (conducted), EN61000-4-11 (Dips) According to EN 61000-3-2 According to EN50178, shock: 5 g in all directions According to EN60204 According to EN61558-2-17 According to EN50178 / VDE0160 SELV according to EN60950, PLEV according to EN60204 VDE0100-410 / according to DIN57100-410 According to VDE0106-101 Type CP M DM 20 CP M CAP Qty. 1 Part No. 1222210000 1 1222240000 connectPower DC/DC converter connectPower DC/DC converter CP DCDC 250W 24V 10A L + H + DC – DC – DC OK 14 13 W Technical data Input data Rated input voltage Input voltage range, DC Current consumption, DC (typ.) Current consumption, DC max. Max. inrush current Input fuse (internal) Recommended back-up fuse Output data Nominal output voltage Adjustment range of output voltage Ramp-up time Max. residual ripple Nominal output current @ Unom Short-circuit protection Overload protection Power boost @ 24 V DC, 60 °C, ED = 5 % General information Efficiency (typ.) Max. power loss (no load) Max. power loss (nominal load) Mains failure bridging @ Inom Length x width x height (mm) Weight Signal indication LED green (DC OK) LED red (fault) DC OK transistor output "1" (max. load) DC OK transistor output "0" DC OK short circuit resistant Floating contact Contact load (NO contact) Relay on/off Connection data Screw connection Number of terminals Wire cross-section, rigid min/max (mm²) Wire cross-section, flexible min/max (mm²) Wire cross-section, AWG/kcmil min/max Tightening torque Reverse polarity protection Approvals Approvals Ordering data 24 V DC 18…31.2 V DC 11 A 15.5 A < 10 A Yes 16 A / DI/II Fusible link 16 A, Char. B Circuit breaker, recommended item #9926251816 QY-1-13-DM-3-16-B1 16 A, Char. C Circuit breaker, recommended item #9926251916 QY-1-13-DM-U2-16 24 V DC ± 1%, 22.5…29.5 V DC ≤ 100 ms < 50 mVss 10 A @ 24 V DC Yes Yes 12 A for 1 min, ED = 5 % 91% <2W < 24 W > 7 ms @ 24 V DC 150 x 60 x 130 1.25 kg Output voltage ≥ 21.6 V Output voltage ≤ 20.4 V Output voltage ≥ 21.6 V ( max. 250 mA) Output voltage ≤ 20.4 V Yes Yes max. 30V DC/0.5 A Output voltage > 21.6 V / < 20.4 V Input Output Screw connection Screw connection 2 for (+-) 7 for (DCOK,13,14,++ ––) 0.5 / 6 0.5 / 6 0.5 / 2.5 0.5 / 2.5 26 / 12 26 / 12 0.5 … 0.6 Nm Yes CE, cURus, TÜV(IEC 60950-1), cULus, GL Type CP DCDC 250W 24V 10A Qty. 1 Part No. 1313320010 3 connectPower PRO-M PRO-M: diode and capacity modules D CP M DM20 1+ 12- H W CP M CAP 11 12 14 21 22 24 3+ 4+ 1+ 2+ 34- 11 12 14 + 12- 2+ Technical data Input Rated input voltage / DC input voltage range Input current Output Rated output voltage / Output voltage Rated (nominal) output current @ UNom Peak current output/Recovery time for capacitor Continous output current @ 24 V DC Voltage monitoring / Floating contact Switching thresholds General data Degree of efficiency Height x width x depth / Weight Ambient temperature (operational) / Storage temperature Humidity Protection degree / Class of protection / Pollution severity Insulation voltage MTBF Mounting position, installation notice EMC / shock / vibration Noise emission acc. to EN55022 Interference immunity test acc. to Resistance to vibration / Shock Electrical safety (applied standards) Electrical machine equipment For use with electronic equipment Safety extra-low voltage Approvals Approvals Connection data Conductor connection system Number of terminals Wire cross-section, rigid min/max (mm²) Wire cross-section, flexible min/max (mm²) Wire cross-section, AWG/kcmil min/max Note 24 V DC / 18…30 V DC 2 x 10 A or 1 x 20 A 24 V DC / 18…30 V DC 24 V DC ± 1 % / Input voltage - 0.7 V 20 A @ 60 °C Depending on the load (typically 40 A for 1 ms) / Approx. 1 sec. 24 A @ 45 °C, 22.5 A @ 55 °C, 15 A @ 70 °C Yes, In both inputs / Yes 21.6 V DC, relay is on for Power Good, 20.4 V DC, relay is off for Power Fail Yes 21.6 V DC, relay is on for Power Good, 20.4 V DC, relay is off for Power Fail > 97% @ 24 V input voltage 130 / 34 / 150 mm / 0.3 kg -25 °C...+70 °C / -40 °C...+85 °C 5...95 %, no condensation IP 20 / III, with no ground connection, for SELV / 2 0.5 kV Input/output housing > 500,000 h acc. to IEC 1709 (SN29500 Horizontal on TS35 mounting rail,w. 50 mm clearance at top/bottom for air circulation. Can be mount side by side w. no space in between. 130 / 34 / 150 mm / 0.4 kg -25 °C...+70 °C / -40 °C...+85 °C 5...95 %, no condensation IP 20 / III, with no ground connection, for SELV / 2 0.5 kV Input/output housing > 500,000 h acc. to IEC 1709 (SN29500 Horizontal on TS35 mounting rail,w. 50 mm clearance at top/bottom for air circulation. Can be mount side by side w. no space in between. Class B EN 61000-4-2 (ESD)|EN 61000-4-3 and EN 610004-8 (fields)|EN 61000-4-4 (burst)|EN 61000-4-5 (surge)|EN 61000-4-6 (conducted) 1 g according to EN50178 / 15 g In all directions Class B EN 61000-4-2 (ESD)|EN 61000-4-3 and EN 61000-4-8 (fields)|EN 61000-4-4 (burst)|EN 61000-4-5 (surge)|EN 61000-4-6 (conducted)|EN 61000-4-11 (dips) 1 g according to EN50178 / 15 g In all directions Acc. to EN60204 Acc. to EN50178 / VDE0160 SELV acc. to EN60950, PLEV acc. to EN60204 Acc. to EN60204 Acc. to EN50178 / VDE0160 SELV acc. to EN60950, PLEV acc. to EN60204 cCSAus; GL; GOSTME25 cULus; GL; GOSTME25 Input Screw connection 4 (1+, 2+, 1-, 2-) 0.5 / 6 0.5 / 2.5 26 / 12 Output Screw connection 4 (3 +, 4 +, 3 -, 4 -) 0.5 / 6 0.5 / 2.5 26 / 12 Input Screw connection 4 (++--) 0.5 / 6 0.5 / 4 26 / 12 Output Screw connection 3 (CO contacts) 0.5 / 6 0.5 / 2.5 26 / 12 For low-impedance connections we recommend 2.5 mm². Ordering data Type CP M DM20 Note Qty. 1 Part No. 1222210000 Type CP M CAP Qty. 1 Part No. 1222240000 Please see 2013 Full Line Catalog 4.3 “Switch-Mode and Uninterruptible Power Supplies” or CP M CAP Installation Instructions as supplied with the product for details on how to properly utilize the Weidmuller capacitance module for pulse triggering for cable circuit breakers. Accessories Note 4 Subject to technical changes · 04/13 · 2.5M · LIT1305