Indicators and configurable displays Contents Indicators and configurable displays Indicators and configurable displays Overview F.2 Process value displays with LED display F.4 Process value displays with LCD display F.20 F 2028820000 F.1 Indicators and configurable displays Overview Indicators and configurable displays In industrial and process automation, displays provide a visual rendering of data and an digital presentation of electrical and non-electrical measurements. They provide essential diagnostics, logging and operational guidance when operating machines and facilities. Displays make dialogue-based operations possible. They show measurements, error messages and also allow processes to be monitored. Displays can also feature digital and analogue outputs, interference-suppression functions, or the ability to calculate certain process variables internally. This turns a simple display into a high-quality process interface capable of independently controlling subprocesses. F F.2 2028820000 Indicators and configurable displays Overview All-purpose … … A fitting solution for any application – with a multitude of input ranges, external of input loop-powered supply, and analogue or digital outputs. Security No additional signal isolation is required since there is a high insulation voltage. F Saves time Easy push-button configuration. IP 65 Protection IP 65 protection allows for use in harsh industrial conditions. Flow rate or volume monitoring with LED display Process value indication with LCD display 2028820000 F.3 Indicators and configurable displays Process value displays with LED display Counters PTX800 SERIES Typical application of PTX800 The configurable monitors of the PTX800 SERIES are available in two designs: 4...20 mA output 12 DC sensor supply Pulse input •PTX800A for analogue (mA, Volts) inputs •PTX800D with digital pulse inputs (NAMUR, NPN/PNP sensors, TTL, etc) The PTX800D can be connected on the input side to all standard initiators (NPN/PNP/Namur) and with other current/ voltage transmitters. The monitor will accept any periodic signal type and can total the input pulses into a “total“ display. It can also calculate the resulting flow rate. External proximity switches can be supplied with 12 V DC directly from the PTX800D. F.4 Output Control Relay 2 Liquid flow Control valves 137.00 mm 96.6 mm PGM ENT 18.0 mm Wall thickness Max 18.0 mm AL2 TOTAL RATE RESET 92.0 mm (+0.8/-0.0 mm) 15.5 mm Gasket AL1 45.0 mm (+0.6/-0.0 mm) 48.8 mm 44.7 mm 143.5 mm Cut-out 15.5 mm The PTX800A counter processes standardised analogue current and voltage signals. Linearisation and filtering functions are available for processing measurement signals. In addition, the counter has a 24 V DC power supply for loop-powered sensors. Remote PLC/SMS Positive Displacement Flowmeter 96.6 mm F Remotel „Reset“ Output Control Relay 1 The eight-digit LED rate/total display can be changed via a button on the front of the unit. Both versions make use of output relays to close values when the “total“ setpoint is reached. They also have electrically-isolated analogue outputs for re-transmission. The display can be globally scaled based on the flow quantity per second, minute, hour or day. The flow-quantity counter can be multiplied by factors of 0.001, 0.01, 0.1, 1, 10, 100 or 1000. This allows for best use of the display. PTX800D 60.0 mm Panel-mounted totaliser/counter/rate monitors Technical Features •Display of the flow quantity/rate • Easily-readable eight-digit LED display • Up to two outputs for alarm monitoring or control • Optional analogue output • Pulse output •Reset function can be controlled locally or remotely, for fill-quantity monitoring (batching) •The most recent measured value is stored in case of a power outage • DC power supply • LED display for values outside of range • Complete electrical isolation • DIN-standard 1/8 front panel with IP 65 protection • Integrated power supply for initiators •Changing the device configuration is possible without performing a new calibration • No internal adjustments needed 2028820000 Indicators and configurable displays Process value displays with LED display Common technical data Display Type Brightness Display value Partial display Time range, partial display Total display Decimal point Status indicator Pulse output Type Display value Pulse duration Cut-off time Analogue output (optional) Type Display range Resolution Load resistance, current Load resistance, voltage Residual ripple Alarm output (optional) Type Switching current Isolation Input reset Type Function General information Supply voltage Power consumption Accuracy Linearity Repeat accuracy Humidity Temperature coefficient Long-term drift Impulse withstand voltage Ambient temperature (operational)/storage temperature 2028820000 Connections Eight digits, red LED, 7.2 mm Adjustable to 14 levels of brightness Percent or real-value displayed Display from 0 to 50,000 (five digits) per sec., min., hour (PT800A also per day) Display from 0 to 99,999,999 (8 digits) Adjustable separately for partial and total display Alarm 1/2; Status LED Transistor output One pulse per signal jump of the total display 32 ms Minimum of 32 ms Current or voltage output configurable with jumper Dependent on the calibration (within 0 to 22 mA, or 0 to 11 V) 1.6 μA or 0.8 mV / Bit ≤ 900 Ω ≥ 1 kΩ < 20 mVss Terminal 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 Signal L+ LSignal + Signal 0V Pulse Optional, depending on type NO contacts Common NC contact NO contacts Common NC contact Supply voltage Analogue output (optional) Pulse output Inputs Alarm channel 1 (optional) Alarm channel 2 (optional) F 2 relay contacts (CO) 3 A at 240 V AC, 5 A at 24 V DC / 110 V AC (resistive load) 1.5 kV between ports Normally open Complete reset (display/alarm) 24 V DC ±10 % 6 W at 24 V DC < 0.05 % < 0.05 % ± 0.02 % of signal range 0...90 % (no condensation) < 0.02 % of signal range 0.1 % / 10,000 h 4 kV (1.2/50 μs) 0 °C...60 °C / –25 °C...70 °C F.5 Indicators and configurable displays Process value displays with LED display PTX800 Series PTX800D Counter and totaliser with additional functionality and limit-value monitoring • Installation in control panels • Pluggable connection terminals • Scalable impulse and frequency counters for digital input signals • Suitable on input side for all standard initiators Digital pulse input 0V 1 7 Reset counter 9 Pull up/down 10 0 V + 11 fin 12 +12 V H L W Technical data +24 V PS f V/I/f Vout/Iout 0V fout Ch 1 (opt) Ch 1 (opt) (opt) + 3 – 4 5 6 NC 13 Common 14 NO 15 NC 16 Common 17 NO 18 Connections Input Type Digital pulse (NAMUR, PNP/NPN, TTL logic, optocoupler, voltage pulse, no-voltage contacts) 0...10 Hz 12 V DC to 25 mA 50 mV...250 V adjustable Configurable (≤ 10 pulse per signal jump) Input signal Sensor supply Input voltage Total display, display range Analogue output (optional) Type (analogue output) Input reset Pulse duration, min. Pulse output Pulse rate, max. General data Type EMC standards Approvals F 2 Current of voltage output, configured with jumper Terminal 7 8 9 10 11 12 Signal Reset by connection to class 12 Setup configuration by connection to class 12 Pull Up /Down Signal –/0 V Signal + 12 V DC Reset Configuration Inputs 100 ms 16 / s RO/AO version with 1 analogue output and 2 alarm outputs DIN EN 61326 CE; cULus; EAC Dimensions Clamping range (nominal / min. / max.) Length x width x height Note Screw connection 1.5 / 0.5 / 2.5 137 / 96.6 / 48.8 Ordering data with analogue/alarm output without analogue / alarm output Type PTX800D RO/AO PTX800D Qty. 1 1 Order No. 7940012323 7940011133 Note Accessories Note F.6 2028820000 PTX800 Series PTX800A Counter and totaliser with additional functionality and limit-value monitoring • Installation in control panels • Pluggable connection terminals • Configurable for analogue current and voltage signals • Linearisation and interference suppression • Power supply for external sensors Analogue current input / voltage input Indicators and configurable displays Process value displays with LED display 0V 1 7 Reset counter 8 Reset common 10 0 V + 11 Vin/Iin 12 +12 V H L W Technical data 2 +24 V PS f V/I/f Vout/Iout 0V fout Ch 1 (opt) Ch 1 (opt) (opt) + 3 – 4 5 6 NC 13 Common 14 NO 15 NC 16 Common 17 NO 18 Connections Input Type Conversion of linear/quadratic input signals into analogue signals Input signal Sensor supply Resolution Input resistance Total display, display range Analogue output (optional) Type (analogue output) Input reset Pulse duration, min. Pulse output Pulse rate, max. General data Type EMC standards Approvals -24...+24 mA / -11...+11 V 24 V DC (up to 25 mA) 0.6 µ, A / 0.3 mV 22 Ω (current input); 1 MΩ (voltage input) 0,001; 0,01; 0,1; 1; 10; 100; 1000 Dimensions Clamping range (nominal / min. / max.) Length x width x height Note Screw connection 1.5 / 0.5 / 2.5 137 / 96.6 / 48.8 Terminal 7 8 9 10 11 12 Signal Reset by connection to class Kl. 8 Common Setup configuration by connection to class 8 Signal –/0 V Signal + 24 V DC Reset Configuration F Inputs Current of voltage output, configured with jumper 250 ms 15 / s RO/AO version with 1 analogue output and 2 alarm outputs DIN EN 61326 CE; cULus; EAC Ordering data with analogue/alarm output without analogue / alarm output Type PTX800A 4-20mA/RO/AO PTX800A 4-20mA Qty. 1 1 Order No. 7940014374 7940010243 Note Accessories Note 2028820000 F.7 Indicators and configurable displays Process value displays with LED display Indicators and configurable displays for analogue signals PMX420 SERIES Typical application of PMX420 Plus Power supply The current/voltage displays of the PMX420 SERIES are available as a pure display unit or optionally with analogue outputs/4 alarm outputs. Relay output for Hi / Lo Level PMX420 Agitator 24 V DC The basic model is suitable for displaying a wide range of bipolar mA or voltage signals. Inputs are isolated from the power supply. An integrated power source is available for supplying external sensors and transmitters. Alarm / Liquid level max. 4 ... 20 mA Input The PMX420 Plus adds four alarm channels (each with it’s own status indicator and relay contact outputs) and a fully isolated analogue current/voltage output. 137.0 mm 96.6 mm 143.5 mm 4 4 . 7 mm PGM 18.0 mm Wall thickness Max 18.0 mm AL1 AL2 AL3 AL4 92.0 mm (+0.8/–0.0 mm) 15.5m m F Return Transmitter 4 8 . 8 mm Device functions can be configured, specifically for the application, using the integrated keypad on the front panel. There are also several other handy features like maximum and minimum value recall, integrated linearisation, an acoustic alarm, a group alarm function, and the option for manual or automatic alarm reset. Flow Signalling contact 4 5 . 0 mm ( + 0. 6/- 0 . 0 m m ) Universal, 4-digit, current/voltage displays Cut-out F.8 60 . 0 m m 11 12 13 14 15 16 17 18 19 20 21 22 1 5. 5m m • 4-digit LED display • Suitable for current and voltage signals • Bipolar inputs • Integrated square root function • Retrieval of min. and max. values • Integral power supply for active sensors • DC power supply • Complete electrical isolation •F our alarm channels and an analogue current/voltage output (PMX420 Plus) • LED alarm status indication • DIN-standard 1/8 front panel with IP 65 protection • Decimal point can be adjusted to any position • Configurable via front-panel keypad 9 6 . 6 mm Technical features: Terminals 1 2 3 4 5 6 7 8 9 10 2028820000 Indicators and configurable displays Process value displays with LED display Common technical data Display Type Display value Display range Status indicator Input Type Input current limits Input voltage limits Input resistance Resolution Sensor current Feed voltage Attenuation factor Functions Values General information Supply voltage Power input Accuracy Linearity Repeat accuracy Humidity Temperature coefficient Long-term drift Cut-off frequency (-3 dB) Step response time Impulse withstand voltage Isolation voltage Data backup Ambient temperature (operational)/storage temperature EMC standard Approvals 2028820000 Connections 4 Digits, red LED, 14.2 mm Percent or real-value displayed 9999 to +9999 Alarm channel 1-4; status LED Current or voltage input is programmable –22…+22 mA (preset for 4...20 mA) –11...+11 V 25 Ω (current input) or 1.5 MΩ (voltage input) 4 µA / 2 mV 4…20 mA 24 V DC ±1.5 V DC (bis 25 mA) 0…99; programmable digital filter Linear or √ 18...50 V DC, other voltages on request 8.5 W @ 24 V DC Typically ± 0.1 % of signal range < 0.05 % ±0.02 of signal range 0...90 % (no condensation) < 0.02 % / °C at 100 % 0.1 % / 10.000 h 5 Hz 300 ms (10...90 %) 4 kV (1,2/50 µs) 2 kV input / output / power supply > 10 years without power supply 0 °C…60 °C / –25 °C…+70 °C DIN EN 61326 CE, cULus Terminal 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 Signal – + + – Signal + sensor supply Configuration Signal + voltage input Signal + current input Signal 0 V Not used NC contact Common NO contacts NC contact Common NO contacts NO contacts Common NO contacts Common Signal + Signal – Supply voltage High level Supply voltage Low level Inputs Alarm channel 1 (only PMX420Plus) Alarm channel 2 (only PMX420Plus) Alarm channel 3 (only PMX420Plus) Alarm channel 4 (only PMX420Plus) Analogue Output (only PMX420Plus) F F.9 Indicators and configurable displays Process value monitoring with LED display PMX420 Series PMX420Plus Universal, 4-character current/voltage display • Display instrument for control panel installation • Pluggable connection terminals • 4-character, scalable display • Simple menu-driven configuration Display with analogue output and 4 alarm channels 4 5 H L 0V + Vin 8 Iin 9 0V +24 V PS +24 V 7 3 V/I NC Common NO NC Common NO NC Common NO NC Common NO Ch 1 (opt) Ch 2 (opt) V/I Ch 3 (opt) Ch 4 (opt) + – – Vout/Iout Iout Vout W 13 14 15 16 17 18 19 20 21 22 23 24 2 3 5 Option Technical data Connections Alarm Type Scaling Output current Output voltage Transmit function Load impedance, voltage/current F Adjustable output for current or voltage Variable 0...22 mA 0...11 V direct or inverted 850 Ω @ 20 mA (current output) / < 500 Ω (voltage output) Residual ripple Alarm Type ≤ 20 mVss Number of channels Type of contact Switching current 4 2 CO contact und 2 NO contacts 5 A @ 240 V AC, 10 A @ 24 V DC 2 kV input / power supply internal Internal Alarm via LED or output signal to external controller Insulation voltage Leakage current quenching Terminal 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 Signal – + + – Signal + sensor supply Configuration Signal + voltage input Signal + current input Signal 0 V Not used NC contact Common NO contacts NC contact Common NO contacts NO contacts Common NO contacts Common Signal + Signal – Supply voltage High level Supply voltage Low level Inputs Alarm channel 1 Alarm channel 2 Alarm channel 3 Alarm channel 4 Analogue Output Screw connection 1.5 / 0.5 / 2.5 137 / 96.6 / 48.8 Dimensions Clamping range (nominal / min. / max.) Length x width x height Note Ordering data Voltage input/Current input Type PMX420Plus Qty. 1 Order No. 7940018957 Note Accessories Note F.10 2028820000 PMX420 Series PMX420 Universal, 4-character current/voltage display • Display instrument for control panel installation • Pluggable connection terminals • 4-character, scalable display • Simple menu-driven configuration Display Indicators and configurable displays Process value monitoring with LED display +24 V 3 H 5 + 24 V 7 Vin + 8 Iin + 9 0V L W Technical data 4 0V PS V/I Connections Display Type Scaling Display range Status indicator Inputs Type Input current Input resistance Resolution Sensor current Current output Transfer functions Power supply Supply voltage Input Attenuation factor General data Sampling rate Linearity Repeat accuracy Temperature coefficient Long-term drift Cut-off frequency (-3 dB) Step response time Insulation coordination Rated voltage Overvoltage category Impulse withstand voltage Insulation voltage Ambient temperature (operational) Storage temperature Pollution degree Humidity Terminal 1 2 3 4 5 6 7 8 9 10 4-digit, red LED, 14.2 mm -9999...9999 Adjustable input for current or voltage -22...+22 mA (preset to 4...20 mA) 25 Ω (current input) or 1.5 MΩ (voltage input) 4 µA / 2 mV 4...20 mA Signal – + + – Signal + sensor supply Configuration Signal + voltage input Signal + current input Signal 0 V Not used Supply voltage High level Supply voltage Low level F Inputs 18...50 V DC, other voltages on request 0...99, programmable digital filter General data < 0.05 % 0.1 % / 10.000 h 5 Hz 4 kV (1.2/50 µs) 2 kV input / power supply 0 °C...60 °C -25 °C...70 °C 0...90 % (no condensation) Screw connection 1.5 / 0.5 / 2.5 137 / 96.6 / 48.8 Dimensions Clamping range (nominal / min. / max.) Length x width x height Note Ordering data Voltage input/Current input Type PMX420 Qty. 1 Order No. 7940018956 Note Accessories Note 2028820000 F.11 Indicators and configurable displays for temperature PMX400 SERIES Typical application of PMX400 Gas phase outlet Remote PLC/SMS The PMX400 SERIES consists of two modules: RTD • Temperature display • Frequency display / tachometer Liquid phase outlet Heater Input A variety of temperature or frequency signals can be processed. On the output side, optional analogue signals are available, as well as either two or four relay contacts for alarm monitoring. The PMX400 HZX frequency display module offers, as default, two open-collector outputs as the relay contacts. The outputs are designated for the alarm function. An integrated power supply can be used for supplying external sensors and input devices. F.12 DC Power Supply Relay Supply e.g. 240 V AC Output Relay Channel 1 137.0 mm 96.6 mm 143.5 mm 4 4 . 7 mm PGM Wall thickness Max 18.0 mm AL2 AL3 AL4 92.0 mm (+0.8/–0.0 mm) Cut-out 4 5 . 0 mm ( + 0. 6/- 0 . 0 m m ) 18.0 mm AL1 15.5m m • Four-digit digital LED display •U p to four alarm channels and an analogue current/ voltage output • Retrieval of min. and max. values • Integral power supply for active sensors • DC power supply • Complete electrical isolation • LED alarm status indication • DIN-standard 1/8 front panel with IP 65 protection • Decimal point can be adjusted to any position • Configurable via front-panel keypad Output Relay Channel 2 PMX400 TMP Contactor Low temp alarm 4 8 . 8 mm Technical features: 4...20 mA output 9 6 . 6 mm F Mixture inlet Separator 60 . 0 m m Four-digit temperature and frequency displays with analogue-value read-out and alarm monitoring 1 5. 5m m Indicators and configurable displays Process value displays with LED display 2028820000 Indicators and configurable displays Process value displays with LED display Common technical data Display Type Display value Display range Status indicator Output Type Scaling Output signal limits Load resistance Residual ripple Transmit function General information Accuracy Linearity Repeat accuracy Humidity Temperature coefficient Long-term drift Cut-off frequency (-3 dB) Impulse withstand voltage Isolation voltage Data backup Ambient temperature (operational)/storage temperature EMC standard Approvals 2028820000 Connections Four-digit, red LED, 14.2 mm Percent or real-value displayed -9999 to +9999 Alarm channel 1-4; Status LED Current or voltage output Variable 0…20 mA or 0…11 V ≤ 850 Ω (current), ≥1 MΩ (voltage) < 20 mVss direct or reverse Typically ± 0.1 % of signal range ≥ 0.05 % ± 0.02 % of signal range 0...90 % (no condensation) ≤ 0.02 % / °C 0.1 % / 10,000 h 5 Hz 4 kV (1.2/50 μs) 1 kV input / output / power supply ≥ 100 years (without power supply) 0 °C…60 °C / –25 °C…75 °C DIN EN 61326 CE, cULus Terminal 1 2 3 4 5 6 7 8 9 10 11 12 8 9 10 11 12 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 Signal – + Signal + Signal – current Supply voltage Analogue output (only for AO version) Optional, depending on type F NO contacts Common NC contact NO contacts Common NC contact Alarm channel 1 (only for 4RO version) Alarm channel 2 (only for 4RO version) Depending on the individual module F.13 Indicators and configurable displays Process value displays with LED display PMX400 Series PMX400TMP • Temperature measuring and monitoring (PT100, thermocouple, mV) • Automatic sensor detection • Automatic compensation for PT100 measurement leads • Cold-junction compensation for thermocouple inputs • Display instrument for control panel installation 0V 1 8 H B 10 11 – L W Thermocouple Technical data mV J Vout/Iout Iout Vout RTDS + 2 – 3 – 5 Option Connections Display Display value Input Type Input signal cold junction compensation Cable-length compensation General data Supply voltage Power consumption Step response time Sampling rate Attenuation factor Type F Bsense A 12 CJC +24 V PS 9 + 2 Terminal 1 2 6 7 8 9 10 11 12 8 9 10 11 12 8 9 10 11 12 Percentage or real value display Thermocouple, PT100 RTD or mV Configurable for 10 ranges automatic automatic 20...28 V DC 6 W @ 24 V DC 300 ms (10...90 %) 5x pro s 0...99, programmable digital filter 4-digit, red LED, 14.2 mm Voltage input/ current input 1 kV input / output / power supply DIN EN 61326 CE; cULus; EAC Insulation voltage EMC standards Approvals Signal – + Connections for changing setup Cold-junction compensation Supply voltage Configuration Thermocouple inputs Not used Not used B B-Sense A RTD inputs Not used mV Signal – mV Signal + Not used mV inputs Thermocouple (type J, K, N, T, E, B, S, R), RTD or mV signals Input Type Dimensions Clamping range (nominal / min. / max.) Length x width x height Note J K N T E B S R RTD mV Screw connection 1.5 / 0.5 / 2.5 137 / 96.6 / 48.8 Max. display range highest lowest 870 °C (1598 °F) 1372 °C (2502 °F) 1300 °C (2372 °F) –50 °C (–58 °F) 400 °C (752 °F) 700 °C (1292 °F) 1800 °C (3272 °F) 0 °C (32 °F) 1768°C (3214 °F) –50 °C (–58 °F) 1768 °C (3214 °F) –50 °C (–58 °F) 820 °C (1508 °F) –220 °C (–364 °F) 200 mV –200 mV Ordering data without analogue / alarm output Type PMX400TMP Qty. 1 Order No. 7940017862 Note Accessories Note F.14 2028820000 PMX400 Series Indicators and configurable displays Process value displays with LED display PMX400HZX • Frequency measuring and monitoring (3-wire NPN/PNP, NPN/PNP Open Collector, TTL logic, solid-state switch, potential-free contacts) • Integrated power supply for external sensors • Two outputs for monitoring limit-values • De-bouncing of switched input pulses 1 10 11 12 L 0V + 2 PS Pull up/down 9 H 0V f fin +12 V W Technical data V/I +24 V + Vout/Iout (opt) 3 0V 4 Alarm Ch 1 5 com 6 Alarm Ch 2 7 NC 13 Ch 3* Common 14 NO Ch 4* 15 NC 16 Common 17 NO 18 *Optional Connections Display Display value Input Type Input signal Sensor supply Input voltage Alarm (channel 1/2) Type Percentage or real value display Adjustable frequencies Configurable for 4 ranges 12 V DC to 25 mA Channel 1/2: transistor output channel 3/4: relay contact (CO) 200 mA 50 V DC Rated switching current Rated switching voltage Alarm (channel 3/4) Type Channel 1/2: transistor output channel 3/4: relay contact (CO) Channel 3/4: 3 A @ 240 V AC / 24 V DC (resistive load) Switching current General data Supply voltage Power consumption Step response time Attenuation factor Type Insulation voltage EMC standards Approvals 24 V DC ± 10 % 6 W @ 24 V DC < 220 ms (10...90 %) 0...99, programmable digital filter RO/AO version with 1 analogue output and 2 alarm outputs 1 kV input / output / power supply DIN EN 61326 CE; cULus; EAC Dimensions Clamping range (nominal / min. / max.) Length x width x height Note Terminal 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 Input range 0...9.999 Hz 0...99.99 Hz 0...999.9 Hz 0...9999 Hz Signal – + Signal + Signal – Common Channel 1 Channel 2 Configuration Pull up / pull down Signal – Signal + 12 V DC Common NC contact NO contacts Common NC contact NO contacts Supply voltage Analogue output (only for AO version) F Alarm channel 1 and 2 (only for 4RO version) Inputs/Configuration (Set-up: 12/8 connection) Alarm channel 3 (only for 4RO version) Alarm channel 4 (only for 4RO version) Offset Resolution 0...9.998 Hz 0...99.98 Hz 0...999.8 Hz 0...9998 Hz 0.001 Hz 0.01 Hz 0.1 Hz 1 Hz Screw connection 1.5 / 0.5 / 2.5 137 / 96.6 / 48.8 Ordering data with analogue/alarm output without analogue / alarm output Type PMX400HZX RO/AO PMX400HZX Qty. 1 1 Order No. 7940011979 7940015595 Note Accessories Note 2028820000 F.15 Universal auto-manual stations AMS400A Universal auto-manual stations Typical application of AMS400A The AMS400A modules are interface devices which are used between controllers / PLCs and valves / actuators in the field. They implement aouto-manual transfer operations for automatically controlled processes. Proportional 4 to 20 mA output Digital high/ low output from PLC AMS400A Typical applications are: PLC •Manual start-up of sensitive processes before handover to automatic control •Manual over-ride in case of controller failure or malfunction. 96.6 mm 48.8 mm 44.4 mm 143.5 mm AUTO Wall thickness Max 18.0 mm MAN ENT 92.0 mm (+0.8/-0.0 mm) 60.0 mm 15.5mm 18.0 mm Cut-out 15.5mm In AA (analogue-analogue) mode, it is possible for a remote source to switch between manual and automatic operations using digital inputs. Ramp rates and additional handover. Two options are available for the method of returning to automatic control, in order to ensure a bumpless transfer. 137.0 mm 96.6 mm Analogue control equipment and analogue control devices • •Digital control equipment and analogue control devices • Digital control equipment and digital control devices PLC sensor, etc. Status output automatic/manual The AMS400A offers three different I/O configurations, which serve as interfaces between: F Acknowledge 4 to 20 mA input 45.0 mm (+0.6/-0.0 mm) Indicators and configurable displays Process value displays with LED display F.16 2028820000 AMS400A AMS400A Universal interface device • Display instrument for control panel installation • 1/8 DIN standard front • IP 65 fully insulated • Pluggable connection terminals Universal interface device Indicators and configurable displays Process value displays with LED display 1 11 12 8 9 10 H L W Technical data Vin/Iin 0V Common Signal amplifier Signal amplifier 0V 2 +24 V Vout/Iout PS V/I V/I 3 0V 4 0V 5 Automatic / manual 6 Change operating mode 7 Connections Display Type Display value Display range Input Type 4-digit, red LED, 14.2 mm Percentage or real value display -9999...9999 Current input or digital input (pulse-controlled or no-voltage contact) 0...24 mA / 0...12 V DC 50 Ω (mA) / 10 MΩ (V) 5x per sec. (current input) 64 ms (digital input) Input signal Input resistance Sampling rate Pulse width, min. Output Type Output analogue Output current Output voltage Last resistor, max. Alarm (RO version only) Type Number of channels Type of contact Ratings General data Supply voltage Power consumption Accuracy Repeat accuracy Temperature coefficient Cut-off frequency (-3 dB) Step response time Impulse withstand voltage Insulation voltage Ambient temperature / Storage temperature EMC standards Approvals Dimensions Clamping range (nominal / min. / max.) Length x width x height Note Analogue and digital output Current or voltage, configured with jumper 0...24 mA 0...18 V 900 Ω @ 20 mA Terminal 1 2 3 4 5 6 7 8 9 10 11 12 Signal – + Signal + Signal – Signal – 0 V Automatic / manual Change operating mode Common Signal amplifier Signal reduction Signal + Signal – Supply voltage Analogue Output F Status outputs Digital inputs Analogue inputs Status relay 2 CO contact 3 A @ 240 V AC or 5 A @ 24 V DC 24 V DC ± 10 %, other voltages on request 6 W @ 24 V DC Typically ± 0.1 % of signal range ± 0.02 % of signal range ≤ 0.02 % / °C 5 Hz 300 ms (10...90 %) 4 kV (1.2/50 µs) 1 kV input / output / power supply / 0 °C...60 °C / -25 °C...70 °C DIN EN 61326 CE; cULus; EAC Screw connection 1.5 / 0.5 / 2.5 137 / 96.6 / 48.8 Ordering data Analogue output Type AMS400A 4-20mA/AO Qty. 1 Order No. 7940011895 Note Accessories Note 2028820000 F.17 Indicators and configurable displays Process value displays with LED display Indicators with scalable displays DI350 3½-digit LED display, auxiliary powered Typical application of DI350 The DI350 is a pair of inexpensive 3½-digit displays - one for analogue current (4-20 mA) and the other for voltage (0-10 V) signals, for use in industrial applications. + 24 V 0V 4 ... 20 mA = 0-150.0 kl or % An integrated regulated power supply can be used to supply two-wire transmitters. The bright seven-segment LEDs are easily visible even in weak lighting. The special filtering properties of the front face give it a wide viewing angle. F + Input Tank container The decimal point can be moved to any of the positions (1.XXX, 1X.XX, 1XX.X or 1XXX) so that it can display values in any range. DI350 – Input Power supply Transmitter [dB] Wiring diagramm DI350 0V +24 V 7 The DIN-standard 1/8 front panel with IP 65 protection ensures reliable operation in wet areas. The connection uses pluggable screw-connection elements. The DI350 models are hazardous area approved cuLus Ex (Class 1 Div. 2, Groups A, B ,C & D) 1 2 3 4 Connections Terminal 1 2 3 4 5 6 7 8 PS + 24 V 0V Vin/Iin 8 V/I 0V Signal 24 V DC power supply sensor 0 V DC power supply sensor Input signal + Input signal – Inputs Not used L– L+ Supply voltage 137.0 mm 96.6 mm Wall thickness Max 18.0 mm 92.0 mm (+0.8/-0.0 mm) 60.0 mm Cut-out 15.5mm 96.6 mm 15.5mm 18.0 mm 45.0 mm (+0.6/-0.0 mm) 48.8 mm 44.7 mm 143.5 mm F.18 2028820000 Indicators and configurable displays Process value displays with LED display DI350 DI350 DI350 • Display instrument for control panel installation • 1/8 DIN standard front • 3½ digits • IP 65 fully insulated • Pluggable connection terminals Display with voltage input Display with current input • Integrated power supply for external sensors • Linearity with an accuracy of 0.1 % of the measuring range • Complete galvanic isolation • Integrated power supply for external sensors • Linearity with an accuracy of 0.1 % of the measuring range • Complete galvanic isolation H L W Technical data Input Input signal Input resistance Supply voltage Display Type Display range Display value Format Settings Offset Range of adjustment General data Supply voltage Power consumption Linearity Humidity Temperature coefficient Long-term drift Step response time Impulse withstand voltage Insulation voltage Ambient temperature / Storage temperature EMC standards Approvals Dimensions Clamping range (nominal / min. / max.) Length x width x height Note 0...10 V 1 MΩ 24 V DC (up to 25 mA) 4...20 mA 22 Ω 24 V DC (up to 25 mA) 3.5 digits, red LED, 14.2 mm -1999…1999 Percentage or real value display 1-line / decimal point: 1.000, 100.0, 10.00 3.5 digits, red LED, 14.2 mm -1999…1999 Percentage or real value display 1-line / decimal point: 1.000, 100.0, 10.00 ± 1200 digital steps 20 - 2100 digital steps ± 1200 digital steps 20 - 2100 digital steps 24 V DC (12...35 V DC) 6 W @ 24 V DC < 0.1 % typ. 0...90 % (no condensation) ≤ 0.02 % / °C 0.1 % / 10.000 h 200 ms (10...90 %) 4 kV (1.2/50 µs) 1 kV input / power supply / 0 °C...60 °C / -25 °C...70 °C DIN EN 61326 CE; cULus; cULusEX; EAC 24 V DC (12...35 V DC) 6 W @ 24 V DC < 0.1 % typ. 0...90 % (no condensation) ≤ 0.02 % / °C 0.1 % / 10.000 h 200 ms (10...90 %) 4 kV (1.2/50 µs) 1 kV input / power supply / 0 °C...60 °C / -25 °C...70 °C DIN EN 61326 CE; cULus; cULusEX; EAC Screw connection 1.5 / 0.5 / 2.5 137 / 96.6 / 48.8 Screw connection 1.5 / 0.5 / 2.5 137 / 96.6 / 48.8 F Ordering data Voltage input/Current input Type DI350 0-10V/0-100.0 Qty. 1 Order No. 7940011570 Type DI350 4-20mA/0-100.0 Qty. 1 Order No. 7940010185 Note Accessories Note 2028820000 F.19 Indicators and configurable displays Process value displays with LCD display Indicators and configurable displays LPD350 3½-digit digital display, loop powered Typical application of LPD350 The LPD350 is a compact, cost effective, 3½ digit digital indicator designed specifically for current loop signals. The decimal point can be moved to any position (1.XXX, 1X.XX, 1XX.X or 1XXX) so that it can display values in a range of ±1999. LPD350 Input 24 V DC 4 ... 20 mA WAVEPak Isolator Temperature probe Output 4 ... 20 mA PLC The LPD350 uses a liquid crystal display which can be read even under poor lighting conditions. No additional wiring is needed for a power supply. The user can simply break the loop and connect to the LPD350. Power supply The housing has a DIN-standard 1/8 front panel with IP 65 protection. The connection uses pluggable screw-connection elements. F.20 44.7 mm 18.0 mm Wall thickness Max 18.0 mm Cut-out 45.0 mm (+0.6/-0.0 mm) 92.0 mm (+0.8/-0.0 mm) 91 mm • Large 3½-digit digital LCD display • 4...20 mA input • Loop-powered two-wire design (125 Ω loop load) • Direct or reverse-action display • Linearity is ± 0.1 % of the corresponding signal range • DIN-standard front-panel with IP 65 protection • Pluggable screw-connection mechanism •Hazardous area approved cuLus Ex (Class 1 Div. 2, Groups A, B, C & D) 48.8 mm Technical features: 96.6 mm 65 mm 96.6 mm F 75 mm 2028820000 LPD350 LPD350 • Display instrument for control panel installation • 1/8 DIN standard front • 3½ digits • IP 65 fully insulated • Pluggable connection terminals Current input Indicators and configurable displays Process value displays with LCD display H 2 Iin 1 0V I L W Technical data Connections Input Input current Voltage drop Input resistance Input current, max. Input current, max. when wired incorrectly Display Type Display range Format Settings Offset Range of adjustment General data Accuracy Repeat accuracy Temperature coefficient Terminal 1 2 4...20 mA 2.5 V @ 20 mA 125 Ω 100 mA constant / 500 mA for 10 s 500 mA constant Signal Input – Input + F 3.5 digits, black LCD with clear background, 12.7 mm -1999…1999 Single-line ± 1999 digital steps in two switching ranges 0...3998 in three switching ranges ± 0.05 % from signal range ± 1 digital step ± 0.05 % of signal range Offset ± 0.1 digital steps per °C adjustment range ± 0.1 digital steps per °C 200 ms (10...90 %) 2,5 x pro s / -20 °C...70 °C / -25 °C...85 °C DIN EN 61326 CE; cULus; cULusEX; EAC Step response time Sampling rate Ambient temperature / Storage temperature EMC standards Approvals Screw connection 1.5 / 0.5 / 2.5 75 / 96.6 / 48.8 Dimensions Clamping range (nominal / min. / max.) Length x width x height Note Ordering data Current input Type LPD350 4-20mA/0-100.0 Qty. 1 Order No. 7940010163 Note Accessories Note 2028820000 F.21 Indicators and configurable displays Process value displays with LCD display Configurable IP 67 field-mounted LCD indicator LPD405F 4½-digit display, loop powered The display is loop powered by the 4...20 mA current loop with no external supply required. The twenty-mm LCD displays can be read even under poor light conditions. A sheet of perforated self-adhesive labels is included. They include standard engineering units and can be used for all label needs. The electronic subassembly is housed in a rugged, glass reinforced polycarbonate, IP 67 case. This housing is suitable for any industrial environment. Typical application of LPD450F 4...20 mA current loop/ 2-wire LPD450F display and flow measurer Measurement probe (hall sensor) Open liquid flow, container, tube lines Optionally available is a pipe mounting bracket which can be used for horizontal and vertical mounting. F PLC control level /enterprise management level 24 V DC 140 mm 65 mm 80 mm • Big 20 mm LCD dispaly • 4...20 mA inputs (two-wire loop-powered) •Integrated signal linearisation (√, x3/2, x5/2 or user-defined) • Min./max. value display feature • IP 67 protection • Pipe mount bracket option •Hazardous area approved cULus Ex (Class 1 Div. 2, Groups A, B, C & D) Mounting holes 60 mm Technical features: P 70 mm 18 mm Mounting holes 120 mm F.22 2028820000 LPD450F LPD450F • Display instrument for outdoor use • 4½ Digits • IP 67 fully insulated • Optionally available with fixing clips for pipe mounting Current input Indicators and configurable displays Process value displays with LCD display Iin H I 0V L W Technical data 0RXQWLQJVNHWFK Input Input current Transmit function Display Type Display value Display range Decimal point General data Supply voltage Voltage drop Accuracy Repeat accuracy Temperature coefficient 4...20 mA √, x3/2, x5/2 or programmable (2-21 steps) 4.5-character, black LCD with clear background, 20 mm Percentage or real value display ±19.999 (0.00…100.00 factory setting) 18888, 1.8888, 18.888, 188.88, 1888.8 Loop powered, via 4...20 mA input < 4.3 V ± 0.05 % from signal range ± 1 digital step ± 0.01 % of signal range Offset ± 0.01 % / °C adjustment range ± 0.1 digital steps or 0.01 % / °C 10...90 % (no condensation) Programmable in 99 steps from 1...30 sec. 16 x pro s 2 x per sec. / 0 °C...60 °C / -25 °C...70 °C DIN EN 61326 CE; cULus; cULusEX; EAC Humidity Step response time Sampling rate Change of display Ambient temperature / Storage temperature EMC standards Approvals F 3LSHPRXQWEUDFNHWFDQ EHÀWWHGWRVXLWDYHUWLFDO RUKRUL]RQWDOSLSH PP Screw connection 1.5 / 0.5 / 2.5 65 / 140 / 80 Dimensions Clamping range (nominal / min. / max.) Length x width x height Note Ordering data Current input Type LPD450F 4-20mA Qty. 1 Order No. 7940010236 Note Accessories Note 2028820000 Fixing clip Pipe Mount Kit - 7940010667 F.23 F F.24 2028820000 Indicators and configurable displays