Download

Indicators and configurable displays
Contents
Indicators and configurable displays
Indicators and configurable displays
Overview
F.2
Process value displays with LED display
F.4
Process value displays with LCD display
F.20
F
2028820000
F.1
Indicators and configurable displays
Overview
Indicators and configurable displays
In industrial and process automation, displays provide
a visual rendering of data and an digital presentation of
electrical and non-electrical measurements. They provide
essential diagnostics, logging and operational guidance
when operating machines and facilities.
Displays make dialogue-based operations possible. They
show measurements, error messages and also allow
processes to be monitored. Displays can also feature
digital and analogue outputs, interference-suppression
functions, or the ability to calculate certain process variables
internally. This turns a simple display into a high-quality
process interface capable of independently controlling subprocesses.
F
F.2
2028820000
Indicators and configurable displays
Overview
All-purpose
…
…
A fitting solution for any application
– with a multitude of input ranges,
external of input loop-powered supply,
and analogue or digital outputs.
Security
No additional signal isolation is
required since there is a high insulation
voltage.
F
Saves time
Easy push-button configuration.
IP 65
Protection
IP 65 protection allows for use in harsh
industrial conditions.
Flow rate or volume monitoring
with LED display
Process value indication with
LCD display
2028820000
F.3
Indicators and configurable displays
Process value displays with LED display
Counters
PTX800 SERIES
Typical application of PTX800
The configurable monitors of the PTX800 SERIES are
available in two designs:
4...20 mA output
12 DC sensor supply
Pulse input
•PTX800A for analogue (mA, Volts) inputs
•PTX800D with digital pulse inputs (NAMUR,
NPN/PNP sensors, TTL, etc)
The PTX800D can be connected on the input side to all
standard initiators (NPN/PNP/Namur) and with other current/
voltage transmitters. The monitor will accept any periodic
signal type and can total the input pulses into a “total“
display.
It can also calculate the resulting flow rate. External
proximity switches can be supplied with 12 V DC directly
from the PTX800D.
F.4
Output Control
Relay 2
Liquid flow
Control valves
137.00 mm
96.6 mm
PGM
ENT
18.0 mm
Wall thickness Max 18.0 mm
AL2
TOTAL
RATE
RESET
92.0 mm (+0.8/-0.0 mm)
15.5 mm
Gasket
AL1
45.0 mm (+0.6/-0.0 mm)
48.8 mm
44.7 mm
143.5 mm
Cut-out
15.5 mm
The PTX800A counter processes standardised analogue
current and voltage signals. Linearisation and filtering
functions are available for processing measurement signals.
In addition, the counter has a 24 V DC power supply for
loop-powered sensors.
Remote
PLC/SMS
Positive Displacement
Flowmeter
96.6 mm
F
Remotel „Reset“
Output Control
Relay 1
The eight-digit LED rate/total display can be changed via
a button on the front of the unit. Both versions make use
of output relays to close values when the “total“ setpoint
is reached. They also have electrically-isolated analogue
outputs for re-transmission.
The display can be globally scaled based on the flow
quantity per second, minute, hour or day. The flow-quantity
counter can be multiplied by factors of 0.001, 0.01, 0.1, 1,
10, 100 or 1000. This allows for best use of the display.
PTX800D
60.0 mm
Panel-mounted totaliser/counter/rate monitors
Technical Features
•Display of the flow quantity/rate
• Easily-readable eight-digit LED display
• Up to two outputs for alarm monitoring or control
• Optional analogue output
• Pulse output
•Reset function can be controlled locally or remotely, for
fill-quantity monitoring (batching)
•The most recent measured value is stored in case of a
power outage
• DC power supply
• LED display for values outside of range
• Complete electrical isolation
• DIN-standard 1/8 front panel with IP 65 protection
• Integrated power supply for initiators
•Changing the device configuration is possible without
performing a new calibration
• No internal adjustments needed
2028820000
Indicators and configurable displays
Process value displays with LED display
Common technical data
Display
Type
Brightness
Display value
Partial display
Time range, partial display
Total display
Decimal point
Status indicator
Pulse output
Type
Display value
Pulse duration
Cut-off time
Analogue output (optional)
Type
Display range
Resolution
Load resistance, current
Load resistance, voltage
Residual ripple
Alarm output (optional)
Type
Switching current
Isolation
Input reset
Type
Function
General information
Supply voltage
Power consumption
Accuracy
Linearity
Repeat accuracy
Humidity
Temperature coefficient
Long-term drift
Impulse withstand voltage
Ambient temperature (operational)/storage temperature
2028820000
Connections
Eight digits, red LED, 7.2 mm
Adjustable to 14 levels of brightness
Percent or real-value displayed
Display from 0 to 50,000 (five digits)
per sec., min., hour (PT800A also per day)
Display from 0 to 99,999,999 (8 digits)
Adjustable separately for partial and total display
Alarm 1/2; Status LED
Transistor output
One pulse per signal jump of the total display
32 ms
Minimum of 32 ms
Current or voltage output configurable with jumper
Dependent on the calibration
(within 0 to 22 mA, or 0 to 11 V)
1.6 μA or 0.8 mV / Bit
≤ 900 Ω
≥ 1 kΩ
< 20 mVss
Terminal
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
Signal
L+
LSignal +
Signal 0V
Pulse
Optional, depending
on type
NO contacts
Common
NC contact
NO contacts
Common
NC contact
Supply voltage
Analogue output
(optional)
Pulse output
Inputs
Alarm channel 1
(optional)
Alarm channel 2
(optional)
F
2 relay contacts (CO)
3 A at 240 V AC, 5 A at 24 V DC / 110 V AC (resistive load)
1.5 kV between ports
Normally open
Complete reset (display/alarm)
24 V DC ±10 %
6 W at 24 V DC
< 0.05 %
< 0.05 %
± 0.02 % of signal range
0...90 % (no condensation)
< 0.02 % of signal range
0.1 % / 10,000 h
4 kV (1.2/50 μs)
0 °C...60 °C / –25 °C...70 °C
F.5
Indicators and configurable displays
Process value displays with LED display
PTX800 Series
PTX800D
Counter and totaliser with additional functionality and
limit-value monitoring
• Installation in control panels
• Pluggable connection terminals
• Scalable impulse and frequency counters for digital input
signals
• Suitable on input side for all standard initiators
Digital pulse input
0V
1
7 Reset counter
9 Pull up/down
10 0 V
+
11 fin
12 +12 V
H
L
W
Technical data
+24 V
PS
f
V/I/f
Vout/Iout
0V
fout
Ch 1 (opt)
Ch 1 (opt)
(opt)
+
3
–
4
5
6
NC
13
Common
14
NO
15
NC
16
Common
17
NO
18
Connections
Input
Type
Digital pulse (NAMUR, PNP/NPN, TTL logic, optocoupler, voltage
pulse, no-voltage contacts)
0...10 Hz
12 V DC to 25 mA
50 mV...250 V adjustable
Configurable (≤ 10 pulse per signal jump)
Input signal
Sensor supply
Input voltage
Total display, display range
Analogue output (optional)
Type (analogue output)
Input reset
Pulse duration, min.
Pulse output
Pulse rate, max.
General data
Type
EMC standards
Approvals
F
2
Current of voltage output, configured with jumper
Terminal
7
8
9
10
11
12
Signal
Reset by connection to
class 12
Setup configuration by
connection to class 12
Pull Up /Down
Signal –/0 V
Signal +
12 V DC
Reset
Configuration
Inputs
100 ms
16 / s
RO/AO version with 1 analogue output and 2 alarm outputs
DIN EN 61326
CE; cULus; EAC
Dimensions
Clamping range (nominal / min. / max.)
Length x width x height
Note
Screw connection
1.5 / 0.5 / 2.5
137 / 96.6 / 48.8
Ordering data
with analogue/alarm output
without analogue / alarm output
Type
PTX800D RO/AO
PTX800D
Qty.
1
1
Order No.
7940012323
7940011133
Note
Accessories
Note
F.6
2028820000
PTX800 Series
PTX800A
Counter and totaliser with additional functionality and
limit-value monitoring
• Installation in control panels
• Pluggable connection terminals
• Configurable for analogue current and voltage signals
• Linearisation and interference suppression
• Power supply for external sensors
Analogue current input / voltage input
Indicators and configurable displays
Process value displays with LED display
0V
1
7 Reset counter
8 Reset common
10 0 V
+
11 Vin/Iin
12 +12 V
H
L
W
Technical data
2
+24 V
PS
f
V/I/f
Vout/Iout
0V
fout
Ch 1 (opt)
Ch 1 (opt)
(opt)
+
3
–
4
5
6
NC
13
Common
14
NO
15
NC
16
Common
17
NO
18
Connections
Input
Type
Conversion of linear/quadratic input signals into analogue signals
Input signal
Sensor supply
Resolution
Input resistance
Total display, display range
Analogue output (optional)
Type (analogue output)
Input reset
Pulse duration, min.
Pulse output
Pulse rate, max.
General data
Type
EMC standards
Approvals
-24...+24 mA / -11...+11 V
24 V DC (up to 25 mA)
0.6 µ, A / 0.3 mV
22 Ω (current input); 1 MΩ (voltage input)
0,001; 0,01; 0,1; 1; 10; 100; 1000
Dimensions
Clamping range (nominal / min. / max.)
Length x width x height
Note
Screw connection
1.5 / 0.5 / 2.5
137 / 96.6 / 48.8
Terminal
7
8
9
10
11
12
Signal
Reset by connection to
class Kl. 8
Common
Setup configuration by
connection to class 8
Signal –/0 V
Signal +
24 V DC
Reset
Configuration
F
Inputs
Current of voltage output, configured with jumper
250 ms
15 / s
RO/AO version with 1 analogue output and 2 alarm outputs
DIN EN 61326
CE; cULus; EAC
Ordering data
with analogue/alarm output
without analogue / alarm output
Type
PTX800A 4-20mA/RO/AO
PTX800A 4-20mA
Qty.
1
1
Order No.
7940014374
7940010243
Note
Accessories
Note
2028820000
F.7
Indicators and configurable displays
Process value displays with LED display
Indicators and configurable displays for analogue signals
PMX420 SERIES
Typical application of PMX420 Plus
Power supply
The current/voltage displays of the PMX420 SERIES are
available as a pure display unit or optionally with
analogue outputs/4 alarm outputs.
Relay output for Hi / Lo Level
PMX420
Agitator
24 V DC
The basic model is suitable for displaying a wide range of
bipolar mA or voltage signals. Inputs are isolated from the
power supply. An integrated power source is available for
supplying external sensors and transmitters.
Alarm / Liquid level max.
4 ... 20 mA
Input
The PMX420 Plus adds four alarm channels (each with it’s
own status indicator and relay contact outputs) and a fully
isolated analogue current/voltage output.
137.0 mm
96.6 mm
143.5 mm
4 4 . 7 mm
PGM
18.0 mm
Wall thickness Max 18.0 mm
AL1
AL2
AL3
AL4
92.0 mm (+0.8/–0.0 mm)
15.5m m
F
Return
Transmitter
4 8 . 8 mm
Device functions can be configured, specifically for the
application, using the integrated keypad on the front panel.
There are also several other handy features like maximum
and minimum value recall, integrated linearisation, an
acoustic alarm, a group alarm function, and the option for
manual or automatic alarm reset.
Flow
Signalling contact
4 5 . 0 mm ( + 0. 6/- 0 . 0 m m )
Universal, 4-digit, current/voltage displays
Cut-out
F.8
60 . 0 m m
11 12 13 14 15 16 17 18 19 20 21 22
1 5. 5m m
• 4-digit LED display
• Suitable for current and voltage signals
• Bipolar inputs
• Integrated square root function
• Retrieval of min. and max. values
• Integral power supply for active sensors
• DC power supply
• Complete electrical isolation
•F
our alarm channels and an analogue current/voltage
output (PMX420 Plus)
• LED alarm status indication
• DIN-standard 1/8 front panel with IP 65 protection
• Decimal point can be adjusted to any position
• Configurable via front-panel keypad
9 6 . 6 mm
Technical features:
Terminals
1 2 3 4
5 6 7 8 9 10
2028820000
Indicators and configurable displays
Process value displays with LED display
Common technical data
Display
Type
Display value
Display range
Status indicator
Input
Type
Input current limits
Input voltage limits
Input resistance
Resolution
Sensor current
Feed voltage
Attenuation factor
Functions
Values
General information
Supply voltage
Power input
Accuracy
Linearity
Repeat accuracy
Humidity
Temperature coefficient
Long-term drift
Cut-off frequency (-3 dB)
Step response time
Impulse withstand voltage
Isolation voltage
Data backup
Ambient temperature (operational)/storage temperature
EMC standard
Approvals
2028820000
Connections
4 Digits, red LED, 14.2 mm
Percent or real-value displayed
9999 to +9999
Alarm channel 1-4; status LED
Current or voltage input is programmable
–22…+22 mA (preset for 4...20 mA)
–11...+11 V
25 Ω (current input) or 1.5 MΩ (voltage input)
4 µA / 2 mV
4…20 mA
24 V DC ±1.5 V DC (bis 25 mA)
0…99; programmable digital filter
Linear or √
18...50 V DC, other voltages on request
8.5 W @ 24 V DC
Typically ± 0.1 % of signal range
< 0.05 %
±0.02 of signal range
0...90 % (no condensation)
< 0.02 % / °C at 100 %
0.1 % / 10.000 h
5 Hz
300 ms (10...90 %)
4 kV (1,2/50 µs)
2 kV input / output / power supply
> 10 years without power supply
0 °C…60 °C / –25 °C…+70 °C
DIN EN 61326
CE, cULus
Terminal
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
Signal
–
+
+
–
Signal + sensor supply
Configuration
Signal + voltage input
Signal + current input
Signal 0 V
Not used
NC contact
Common
NO contacts
NC contact
Common
NO contacts
NO contacts
Common
NO contacts
Common
Signal +
Signal –
Supply voltage
High level
Supply voltage
Low level
Inputs
Alarm channel 1
(only PMX420Plus)
Alarm channel 2
(only PMX420Plus)
Alarm channel 3
(only PMX420Plus)
Alarm channel 4
(only PMX420Plus)
Analogue Output
(only PMX420Plus)
F
F.9
Indicators and configurable displays
Process value monitoring with LED display
PMX420 Series
PMX420Plus
Universal, 4-character current/voltage display
• Display instrument for control panel installation
• Pluggable connection terminals
• 4-character, scalable display
• Simple menu-driven configuration
Display with analogue output and 4 alarm channels
4
5
H
L
0V
+ Vin
8
Iin
9
0V
+24 V
PS
+24 V
7
3
V/I
NC
Common
NO
NC
Common
NO
NC
Common
NO
NC
Common
NO
Ch 1 (opt)
Ch 2 (opt)
V/I
Ch 3 (opt)
Ch 4 (opt)
+
–
–
Vout/Iout
Iout
Vout
W
13
14
15
16
17
18
19
20
21
22
23
24
2
3
5
Option
Technical data
Connections
Alarm
Type
Scaling
Output current
Output voltage
Transmit function
Load impedance, voltage/current
F
Adjustable output for current or voltage
Variable
0...22 mA
0...11 V
direct or inverted
850 Ω @ 20 mA (current output) / < 500 Ω (voltage output)
Residual ripple
Alarm
Type
≤ 20 mVss
Number of channels
Type of contact
Switching current
4
2 CO contact und 2 NO contacts
5 A @ 240 V AC,
10 A @ 24 V DC
2 kV input / power supply
internal
Internal Alarm via LED or output signal to external controller
Insulation voltage
Leakage current quenching
Terminal
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
Signal
–
+
+
–
Signal + sensor supply
Configuration
Signal + voltage input
Signal + current input
Signal 0 V
Not used
NC contact
Common
NO contacts
NC contact
Common
NO contacts
NO contacts
Common
NO contacts
Common
Signal +
Signal –
Supply voltage
High level
Supply voltage
Low level
Inputs
Alarm channel 1
Alarm channel 2
Alarm channel 3
Alarm channel 4
Analogue Output
Screw connection
1.5 / 0.5 / 2.5
137 / 96.6 / 48.8
Dimensions
Clamping range (nominal / min. / max.)
Length x width x height
Note
Ordering data
Voltage input/Current input
Type
PMX420Plus
Qty.
1
Order No.
7940018957
Note
Accessories
Note
F.10
2028820000
PMX420 Series
PMX420
Universal, 4-character current/voltage display
• Display instrument for control panel installation
• Pluggable connection terminals
• 4-character, scalable display
• Simple menu-driven configuration
Display
Indicators and configurable displays
Process value monitoring with LED display
+24 V
3
H
5 + 24 V
7 Vin
+
8 Iin
+
9 0V
L
W
Technical data
4
0V
PS
V/I
Connections
Display
Type
Scaling
Display range
Status indicator
Inputs
Type
Input current
Input resistance
Resolution
Sensor current
Current output
Transfer functions
Power supply
Supply voltage
Input
Attenuation factor
General data
Sampling rate
Linearity
Repeat accuracy
Temperature coefficient
Long-term drift
Cut-off frequency (-3 dB)
Step response time
Insulation coordination
Rated voltage
Overvoltage category
Impulse withstand voltage
Insulation voltage
Ambient temperature (operational)
Storage temperature
Pollution degree
Humidity
Terminal
1
2
3
4
5
6
7
8
9
10
4-digit, red LED, 14.2 mm
-9999...9999
Adjustable input for current or voltage
-22...+22 mA (preset to 4...20 mA)
25 Ω (current input) or 1.5 MΩ (voltage input)
4 µA / 2 mV
4...20 mA
Signal
–
+
+
–
Signal + sensor supply
Configuration
Signal + voltage input
Signal + current input
Signal 0 V
Not used
Supply voltage
High level
Supply voltage
Low level
F
Inputs
18...50 V DC, other voltages on request
0...99, programmable digital filter
General data
< 0.05 %
0.1 % / 10.000 h
5 Hz
4 kV (1.2/50 µs)
2 kV input / power supply
0 °C...60 °C
-25 °C...70 °C
0...90 % (no condensation)
Screw connection
1.5 / 0.5 / 2.5
137 / 96.6 / 48.8
Dimensions
Clamping range (nominal / min. / max.)
Length x width x height
Note
Ordering data
Voltage input/Current input
Type
PMX420
Qty.
1
Order No.
7940018956
Note
Accessories
Note
2028820000
F.11
Indicators and configurable displays for temperature
PMX400 SERIES
Typical application of PMX400
Gas phase outlet
Remote
PLC/SMS
The PMX400 SERIES consists of two modules:
RTD
• Temperature display
• Frequency display / tachometer
Liquid phase outlet
Heater
Input
A variety of temperature or frequency signals can be
processed. On the output side, optional analogue signals
are available, as well as either two or four relay contacts
for alarm monitoring. The PMX400 HZX frequency display
module offers, as default, two open-collector outputs as
the relay contacts. The outputs are designated for the
alarm function. An integrated power supply can be used for
supplying external sensors and input devices.
F.12
DC Power Supply
Relay Supply
e.g. 240 V AC
Output Relay
Channel 1
137.0 mm
96.6 mm
143.5 mm
4 4 . 7 mm
PGM
Wall thickness Max 18.0 mm
AL2
AL3
AL4
92.0 mm (+0.8/–0.0 mm)
Cut-out
4 5 . 0 mm ( + 0. 6/- 0 . 0 m m )
18.0 mm
AL1
15.5m m
• Four-digit digital LED display
•U
p to four alarm channels and an analogue current/
voltage output
• Retrieval of min. and max. values
• Integral power supply for active sensors
• DC power supply
• Complete electrical isolation
• LED alarm status indication
• DIN-standard 1/8 front panel with IP 65 protection
• Decimal point can be adjusted to any position
• Configurable via front-panel keypad
Output Relay
Channel 2
PMX400
TMP
Contactor
Low temp alarm
4 8 . 8 mm
Technical features:
4...20 mA output
9 6 . 6 mm
F
Mixture inlet
Separator
60 . 0 m m
Four-digit temperature and frequency displays with
analogue-value read-out and alarm monitoring
1 5. 5m m
Indicators and configurable displays
Process value displays with LED display
2028820000
Indicators and configurable displays
Process value displays with LED display
Common technical data
Display
Type
Display value
Display range
Status indicator
Output
Type
Scaling
Output signal limits
Load resistance
Residual ripple
Transmit function
General information
Accuracy
Linearity
Repeat accuracy
Humidity
Temperature coefficient
Long-term drift
Cut-off frequency (-3 dB)
Impulse withstand voltage
Isolation voltage
Data backup
Ambient temperature (operational)/storage temperature
EMC standard
Approvals
2028820000
Connections
Four-digit, red LED, 14.2 mm
Percent or real-value displayed
-9999 to +9999
Alarm channel 1-4; Status LED
Current or voltage output
Variable
0…20 mA or 0…11 V
≤ 850 Ω (current), ≥1 MΩ (voltage)
< 20 mVss
direct or reverse
Typically ± 0.1 % of signal range
≥ 0.05 %
± 0.02 % of signal range
0...90 % (no condensation)
≤ 0.02 % / °C
0.1 % / 10,000 h
5 Hz
4 kV (1.2/50 μs)
1 kV input / output / power supply
≥ 100 years (without power supply)
0 °C…60 °C / –25 °C…75 °C
DIN EN 61326
CE, cULus
Terminal
1
2
3
4
5
6
7
8
9
10
11
12
8
9
10
11
12
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
Signal
–
+
Signal +
Signal – current
Supply voltage
Analogue output
(only for AO version)
Optional, depending on type
F
NO contacts
Common
NC contact
NO contacts
Common
NC contact
Alarm channel 1
(only for 4RO version)
Alarm channel 2
(only for 4RO version)
Depending on the individual module
F.13
Indicators and configurable displays
Process value displays with LED display
PMX400 Series
PMX400TMP
• Temperature measuring and monitoring (PT100,
thermocouple, mV)
• Automatic sensor detection
• Automatic compensation for PT100 measurement leads
• Cold-junction compensation for thermocouple inputs
• Display instrument for control panel installation
0V
1
8
H
B 10
11
–
L
W
Thermocouple
Technical data
mV
J
Vout/Iout
Iout
Vout
RTDS
+ 2
– 3
– 5
Option
Connections
Display
Display value
Input
Type
Input signal
cold junction compensation
Cable-length compensation
General data
Supply voltage
Power consumption
Step response time
Sampling rate
Attenuation factor
Type
F
Bsense
A 12
CJC
+24 V
PS
9
+
2
Terminal
1
2
6
7
8
9
10
11
12
8
9
10
11
12
8
9
10
11
12
Percentage or real value display
Thermocouple, PT100 RTD or mV
Configurable for 10 ranges
automatic
automatic
20...28 V DC
6 W @ 24 V DC
300 ms (10...90 %)
5x pro s
0...99, programmable digital filter
4-digit, red LED, 14.2 mm
Voltage input/ current input
1 kV input / output / power supply
DIN EN 61326
CE; cULus; EAC
Insulation voltage
EMC standards
Approvals
Signal
–
+
Connections for
changing setup
Cold-junction
compensation
Supply voltage
Configuration
Thermocouple inputs
Not used
Not used
B
B-Sense
A
RTD inputs
Not used
mV Signal –
mV Signal +
Not used
mV inputs
Thermocouple (type J, K, N, T, E, B, S, R),
RTD or mV signals
Input Type
Dimensions
Clamping range (nominal / min. / max.)
Length x width x height
Note
J
K
N
T
E
B
S
R
RTD
mV
Screw connection
1.5 / 0.5 / 2.5
137 / 96.6 / 48.8
Max. display range
highest
lowest
870 °C (1598 °F)
1372 °C (2502 °F)
1300 °C (2372 °F)
–50 °C (–58 °F)
400 °C (752 °F)
700 °C (1292 °F)
1800 °C (3272 °F)
0 °C (32 °F)
1768°C (3214 °F)
–50 °C (–58 °F)
1768 °C (3214 °F)
–50 °C (–58 °F)
820 °C (1508 °F)
–220 °C (–364 °F)
200 mV
–200 mV
Ordering data
without analogue / alarm output
Type
PMX400TMP
Qty.
1
Order No.
7940017862
Note
Accessories
Note
F.14
2028820000
PMX400 Series
Indicators and configurable displays
Process value displays with LED display
PMX400HZX
• Frequency measuring and monitoring (3-wire NPN/PNP,
NPN/PNP Open Collector, TTL logic, solid-state switch,
potential-free contacts)
• Integrated power supply for external sensors
• Two outputs for monitoring limit-values
• De-bouncing of switched input pulses
1
10
11
12
L
0V
+
2
PS
Pull up/down
9
H
0V
f
fin
+12 V
W
Technical data
V/I
+24 V
+
Vout/Iout (opt)
3
0V
4
Alarm Ch 1
5
com
6
Alarm Ch 2
7
NC
13
Ch 3*
Common 14
NO
Ch 4*
15
NC
16
Common 17
NO
18
*Optional
Connections
Display
Display value
Input
Type
Input signal
Sensor supply
Input voltage
Alarm (channel 1/2)
Type
Percentage or real value display
Adjustable frequencies
Configurable for 4 ranges
12 V DC to 25 mA
Channel 1/2: transistor output
channel 3/4: relay contact (CO)
200 mA
50 V DC
Rated switching current
Rated switching voltage
Alarm (channel 3/4)
Type
Channel 1/2: transistor output
channel 3/4: relay contact (CO)
Channel 3/4: 3 A @ 240 V AC / 24 V DC (resistive load)
Switching current
General data
Supply voltage
Power consumption
Step response time
Attenuation factor
Type
Insulation voltage
EMC standards
Approvals
24 V DC ± 10 %
6 W @ 24 V DC
< 220 ms (10...90 %)
0...99, programmable digital filter
RO/AO version with 1 analogue output and 2 alarm outputs
1 kV input / output / power supply
DIN EN 61326
CE; cULus; EAC
Dimensions
Clamping range (nominal / min. / max.)
Length x width x height
Note
Terminal
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
Input
range
0...9.999 Hz
0...99.99 Hz
0...999.9 Hz
0...9999 Hz
Signal
–
+
Signal +
Signal –
Common
Channel 1
Channel 2
Configuration
Pull up / pull down
Signal –
Signal +
12 V DC
Common
NC contact
NO contacts
Common
NC contact
NO contacts
Supply voltage
Analogue output
(only for AO version)
F
Alarm channel 1 and 2
(only for 4RO version)
Inputs/Configuration
(Set-up: 12/8 connection)
Alarm channel 3
(only for 4RO version)
Alarm channel 4
(only for 4RO version)
Offset
Resolution
0...9.998 Hz
0...99.98 Hz
0...999.8 Hz
0...9998 Hz
0.001 Hz
0.01 Hz
0.1 Hz
1 Hz
Screw connection
1.5 / 0.5 / 2.5
137 / 96.6 / 48.8
Ordering data
with analogue/alarm output
without analogue / alarm output
Type
PMX400HZX RO/AO
PMX400HZX
Qty.
1
1
Order No.
7940011979
7940015595
Note
Accessories
Note
2028820000
F.15
Universal auto-manual stations
AMS400A
Universal auto-manual stations
Typical application of AMS400A
The AMS400A modules are interface devices which are
used between controllers / PLCs and valves / actuators in the
field. They implement aouto-manual transfer operations for
automatically controlled processes.
Proportional 4 to 20 mA output
Digital high/
low output
from PLC
AMS400A
Typical applications are:
PLC
•Manual start-up of sensitive processes before handover to
automatic control
•Manual over-ride in case of controller failure or
malfunction.
96.6 mm
48.8 mm
44.4 mm
143.5 mm
AUTO
Wall thickness Max 18.0 mm
MAN
ENT
92.0 mm (+0.8/-0.0 mm)
60.0 mm
15.5mm
18.0 mm
Cut-out
15.5mm
In AA (analogue-analogue) mode, it is possible for a remote
source to switch between manual and automatic operations
using digital inputs. Ramp rates and additional handover.
Two options are available for the method of returning to
automatic control, in order to ensure a bumpless transfer.
137.0 mm
96.6 mm
Analogue control equipment and analogue control devices
•
•Digital control equipment and analogue control devices
• Digital control equipment and digital control devices
PLC
sensor,
etc.
Status output
automatic/manual
The AMS400A offers three different I/O configurations,
which serve as interfaces between:
F
Acknowledge
4 to 20 mA input
45.0 mm (+0.6/-0.0 mm)
Indicators and configurable displays
Process value displays with LED display
F.16
2028820000
AMS400A
AMS400A
Universal interface device
• Display instrument for control panel installation
• 1/8 DIN standard front
• IP 65 fully insulated
• Pluggable connection terminals
Universal interface device
Indicators and configurable displays
Process value displays with LED display
1
11
12
8
9
10
H
L
W
Technical data
Vin/Iin
0V
Common
Signal amplifier
Signal amplifier
0V
2
+24 V
Vout/Iout
PS
V/I
V/I
3
0V
4
0V
5
Automatic / manual 6
Change operating mode 7
Connections
Display
Type
Display value
Display range
Input
Type
4-digit, red LED, 14.2 mm
Percentage or real value display
-9999...9999
Current input or digital input (pulse-controlled or no-voltage contact)
0...24 mA / 0...12 V DC
50 Ω (mA) / 10 MΩ (V)
5x per sec. (current input)
64 ms (digital input)
Input signal
Input resistance
Sampling rate
Pulse width, min.
Output
Type
Output analogue
Output current
Output voltage
Last resistor, max.
Alarm (RO version only)
Type
Number of channels
Type of contact
Ratings
General data
Supply voltage
Power consumption
Accuracy
Repeat accuracy
Temperature coefficient
Cut-off frequency (-3 dB)
Step response time
Impulse withstand voltage
Insulation voltage
Ambient temperature / Storage temperature
EMC standards
Approvals
Dimensions
Clamping range (nominal / min. / max.)
Length x width x height
Note
Analogue and digital output
Current or voltage, configured with jumper
0...24 mA
0...18 V
900 Ω @ 20 mA
Terminal
1
2
3
4
5
6
7
8
9
10
11
12
Signal
–
+
Signal +
Signal –
Signal – 0 V
Automatic / manual
Change operating mode
Common
Signal amplifier
Signal reduction
Signal +
Signal –
Supply voltage
Analogue Output
F
Status outputs
Digital inputs
Analogue inputs
Status relay
2
CO contact
3 A @ 240 V AC or 5 A @ 24 V DC
24 V DC ± 10 %, other voltages on request
6 W @ 24 V DC
Typically ± 0.1 % of signal range
± 0.02 % of signal range
≤ 0.02 % / °C
5 Hz
300 ms (10...90 %)
4 kV (1.2/50 µs)
1 kV input / output / power supply
/ 0 °C...60 °C / -25 °C...70 °C
DIN EN 61326
CE; cULus; EAC
Screw connection
1.5 / 0.5 / 2.5
137 / 96.6 / 48.8
Ordering data
Analogue output
Type
AMS400A 4-20mA/AO
Qty.
1
Order No.
7940011895
Note
Accessories
Note
2028820000
F.17
Indicators and configurable displays
Process value displays with LED display
Indicators with scalable displays
DI350
3½-digit LED display, auxiliary powered
Typical application of DI350
The DI350 is a pair of inexpensive 3½-digit displays - one for
analogue current (4-20 mA) and the other for voltage
(0-10 V) signals, for use in industrial applications.
+ 24 V
0V
4 ... 20 mA = 0-150.0 kl
or %
An integrated regulated power supply can be used to supply
two-wire transmitters.
The bright seven-segment LEDs are easily visible even in
weak lighting. The special filtering properties of the front
face give it a wide viewing angle.
F
+ Input
Tank container
The decimal point can be moved to any of the positions
(1.XXX, 1X.XX, 1XX.X or 1XXX) so that it can display values
in any range.
DI350
– Input
Power supply
Transmitter [dB]
Wiring diagramm DI350
0V
+24 V
7
The DIN-standard 1/8 front panel with IP 65 protection
ensures reliable operation in wet areas. The connection uses
pluggable screw-connection elements.
The DI350 models are hazardous area approved cuLus Ex
(Class 1 Div. 2, Groups A, B ,C & D)
1
2
3
4
Connections
Terminal
1
2
3
4
5
6
7
8
PS
+ 24 V
0V
Vin/Iin
8
V/I
0V
Signal
24 V DC
power supply sensor
0 V DC
power supply sensor
Input signal +
Input signal –
Inputs
Not used
L–
L+
Supply voltage
137.0 mm
96.6 mm
Wall thickness Max 18.0 mm
92.0 mm (+0.8/-0.0 mm)
60.0 mm
Cut-out
15.5mm
96.6 mm
15.5mm
18.0 mm
45.0 mm (+0.6/-0.0 mm)
48.8 mm
44.7 mm
143.5 mm
F.18
2028820000
Indicators and configurable displays
Process value displays with LED display
DI350
DI350
DI350
• Display instrument for control panel installation
• 1/8 DIN standard front
• 3½ digits
• IP 65 fully insulated
• Pluggable connection terminals
Display with voltage input
Display with current input
• Integrated power supply for external sensors
• Linearity with an accuracy of 0.1 % of the measuring
range
• Complete galvanic isolation
• Integrated power supply for external sensors
• Linearity with an accuracy of 0.1 % of the measuring
range
• Complete galvanic isolation
H
L
W
Technical data
Input
Input signal
Input resistance
Supply voltage
Display
Type
Display range
Display value
Format
Settings
Offset
Range of adjustment
General data
Supply voltage
Power consumption
Linearity
Humidity
Temperature coefficient
Long-term drift
Step response time
Impulse withstand voltage
Insulation voltage
Ambient temperature / Storage temperature
EMC standards
Approvals
Dimensions
Clamping range (nominal / min. / max.)
Length x width x height
Note
0...10 V
1 MΩ
24 V DC (up to 25 mA)
4...20 mA
22 Ω
24 V DC (up to 25 mA)
3.5 digits, red LED, 14.2 mm
-1999…1999
Percentage or real value display
1-line / decimal point: 1.000, 100.0, 10.00
3.5 digits, red LED, 14.2 mm
-1999…1999
Percentage or real value display
1-line / decimal point: 1.000, 100.0, 10.00
± 1200 digital steps
20 - 2100 digital steps
± 1200 digital steps
20 - 2100 digital steps
24 V DC (12...35 V DC)
6 W @ 24 V DC
< 0.1 % typ.
0...90 % (no condensation)
≤ 0.02 % / °C
0.1 % / 10.000 h
200 ms (10...90 %)
4 kV (1.2/50 µs)
1 kV input / power supply
/ 0 °C...60 °C / -25 °C...70 °C
DIN EN 61326
CE; cULus; cULusEX; EAC
24 V DC (12...35 V DC)
6 W @ 24 V DC
< 0.1 % typ.
0...90 % (no condensation)
≤ 0.02 % / °C
0.1 % / 10.000 h
200 ms (10...90 %)
4 kV (1.2/50 µs)
1 kV input / power supply
/ 0 °C...60 °C / -25 °C...70 °C
DIN EN 61326
CE; cULus; cULusEX; EAC
Screw connection
1.5 / 0.5 / 2.5
137 / 96.6 / 48.8
Screw connection
1.5 / 0.5 / 2.5
137 / 96.6 / 48.8
F
Ordering data
Voltage input/Current input
Type
DI350 0-10V/0-100.0
Qty.
1
Order No.
7940011570
Type
DI350 4-20mA/0-100.0
Qty.
1
Order No.
7940010185
Note
Accessories
Note
2028820000
F.19
Indicators and configurable displays
Process value displays with LCD display
Indicators and configurable displays
LPD350
3½-digit digital display, loop powered
Typical application of LPD350
The LPD350 is a compact, cost effective, 3½ digit digital
indicator designed specifically for current loop signals. The
decimal point can be moved to any position (1.XXX, 1X.XX,
1XX.X or 1XXX) so that it can display values in a range of
±1999.
LPD350
Input
24 V DC
4 ... 20 mA
WAVEPak
Isolator
Temperature
probe
Output
4 ... 20 mA
PLC
The LPD350 uses a liquid crystal display which can be read
even under poor lighting conditions.
No additional wiring is needed for a power supply. The user
can simply break the loop and connect to the LPD350.
Power supply
The housing has a DIN-standard 1/8 front panel with IP 65
protection. The connection uses pluggable screw-connection
elements.
F.20
44.7 mm
18.0 mm
Wall thickness Max 18.0 mm
Cut-out
45.0 mm (+0.6/-0.0 mm)
92.0 mm (+0.8/-0.0 mm)
91 mm
• Large 3½-digit digital LCD display
• 4...20 mA input
• Loop-powered two-wire design (125 Ω loop load)
• Direct or reverse-action display
• Linearity is ± 0.1 % of the corresponding signal range
• DIN-standard front-panel with IP 65 protection
• Pluggable screw-connection mechanism
•Hazardous area approved cuLus Ex (Class 1 Div. 2,
Groups A, B, C & D)
48.8 mm
Technical features:
96.6 mm
65 mm
96.6 mm
F
75 mm
2028820000
LPD350
LPD350
• Display instrument for control panel installation
• 1/8 DIN standard front
• 3½ digits
• IP 65 fully insulated
• Pluggable connection terminals
Current input
Indicators and configurable displays
Process value displays with LCD display
H
2
Iin
1
0V
I
L
W
Technical data
Connections
Input
Input current
Voltage drop
Input resistance
Input current, max.
Input current, max. when wired incorrectly
Display
Type
Display range
Format
Settings
Offset
Range of adjustment
General data
Accuracy
Repeat accuracy
Temperature coefficient
Terminal
1
2
4...20 mA
2.5 V @ 20 mA
125 Ω
100 mA constant / 500 mA for 10 s
500 mA constant
Signal
Input –
Input +
F
3.5 digits, black LCD with clear background, 12.7 mm
-1999…1999
Single-line
± 1999 digital steps in two switching ranges
0...3998 in three switching ranges
± 0.05 % from signal range ± 1 digital step
± 0.05 % of signal range
Offset ± 0.1 digital steps per °C
adjustment range ± 0.1 digital steps per °C
200 ms (10...90 %)
2,5 x pro s
/ -20 °C...70 °C / -25 °C...85 °C
DIN EN 61326
CE; cULus; cULusEX; EAC
Step response time
Sampling rate
Ambient temperature / Storage temperature
EMC standards
Approvals
Screw connection
1.5 / 0.5 / 2.5
75 / 96.6 / 48.8
Dimensions
Clamping range (nominal / min. / max.)
Length x width x height
Note
Ordering data
Current input
Type
LPD350 4-20mA/0-100.0
Qty.
1
Order No.
7940010163
Note
Accessories
Note
2028820000
F.21
Indicators and configurable displays
Process value displays with LCD display
Configurable IP 67 field-mounted LCD indicator
LPD405F
4½-digit display, loop powered
The display is loop powered by the 4...20 mA current loop
with no external supply required. The twenty-mm LCD
displays can be read even under poor light conditions.
A sheet of perforated self-adhesive labels is included. They
include standard engineering units and can be used for all
label needs.
The electronic subassembly is housed in a rugged, glass
reinforced polycarbonate, IP 67 case. This housing is suitable
for any industrial environment.
Typical application of LPD450F
4...20 mA current loop/
2-wire
LPD450F display and
flow measurer
Measurement
probe
(hall sensor)
Open liquid flow,
container, tube lines
Optionally available is a pipe mounting bracket which can be
used for horizontal and vertical mounting.
F
PLC control
level /enterprise
management
level
24 V DC
140 mm
65 mm
80 mm
• Big 20 mm LCD dispaly
• 4...20 mA inputs (two-wire loop-powered)
•Integrated signal linearisation (√, x3/2, x5/2 or user-defined)
• Min./max. value display feature
• IP 67 protection
• Pipe mount bracket option
•Hazardous area approved cULus Ex (Class 1 Div. 2,
Groups A, B, C & D)
Mounting holes 60 mm
Technical features:
P
70 mm
18 mm
Mounting holes 120 mm
F.22
2028820000
LPD450F
LPD450F
• Display instrument for outdoor use
• 4½ Digits
• IP 67 fully insulated
• Optionally available with fixing clips for pipe mounting
Current input
Indicators and configurable displays
Process value displays with LCD display
Iin
H
I
0V
L
W
Technical data
0RXQWLQJVNHWFK
Input
Input current
Transmit function
Display
Type
Display value
Display range
Decimal point
General data
Supply voltage
Voltage drop
Accuracy
Repeat accuracy
Temperature coefficient
4...20 mA
√, x3/2, x5/2 or programmable (2-21 steps)
4.5-character, black LCD with clear background, 20 mm
Percentage or real value display
±19.999 (0.00…100.00 factory setting)
18888, 1.8888, 18.888, 188.88, 1888.8
Loop powered, via 4...20 mA input
< 4.3 V
± 0.05 % from signal range ± 1 digital step
± 0.01 % of signal range
Offset ± 0.01 % / °C
adjustment range ± 0.1 digital steps or 0.01 % / °C
10...90 % (no condensation)
Programmable in 99 steps from 1...30 sec.
16 x pro s
2 x per sec.
/ 0 °C...60 °C / -25 °C...70 °C
DIN EN 61326
CE; cULus; cULusEX; EAC
Humidity
Step response time
Sampling rate
Change of display
Ambient temperature / Storage temperature
EMC standards
Approvals
F
3LSHPRXQWEUDFNHWFDQ
EHÀWWHGWRVXLWDYHUWLFDO
RUKRUL]RQWDOSLSH
PP
Screw connection
1.5 / 0.5 / 2.5
65 / 140 / 80
Dimensions
Clamping range (nominal / min. / max.)
Length x width x height
Note
Ordering data
Current input
Type
LPD450F 4-20mA
Qty.
1
Order No.
7940010236
Note
Accessories
Note
2028820000
Fixing clip
Pipe Mount Kit - 7940010667
F.23
F
F.24
2028820000
Indicators and configurable displays