Datasheet ACT20M Signal Isolation and Conversion NEW Weidmuller’s new 8-pole housing, module power can be distributed through the rail for minimized power wiring and reduced installation costs. This “Power Rail” provides the flexibility to add or remove individual modules quickly and easily without affecting the wiring or operation of other components on the rail. The ACT20M range offers D.C. and temperature isolators and converters for use in industrial and marine applications. Configuration is simple because the ACT20M modules require no calibration. Models with selectable temperature, voltage and current ranges feature DIP switches. For the Universal input model, Weidmuller provides vendorindependent, FDT-based configuration software available for download from the Weidmuller website. High quality signal isolation and conversion in a slim 6mm wide housing format is now available with Weidmuller’s ACT20M range. Features include worldwide approvals for both standard and hazardous area installations. This series of single- and dual-channel models extends Weidmuller’s signal conditioning portfolio with a package of solutions for industrial process measurement and control applications. ACT20M is designed to reduce the time and cost of building control panels. DIN-rail mounted in Weidmuller, Canada 10 Spy Court Markham, Ontario L3R 5H6 Telephone: (800) 268-4080 Facsimile: (877) 300-5635 Email: [email protected] Website: www.weidmuller.ca Weidmuller, Mexico Blvd. Hermanos Serdán 698, Col. San Rafael Oriente Puebla, Puebla, Mexico C.P. 72029 Telephone: 01 222 2686267 Facsimile: 01 222 2686219 Email: [email protected] Website: www.weidmuller.com.mx Features: • Very high density analog signal isolation and conversion • Easy installation with Power Rail cross-connect option • DIP switches for calibration-free re-ranging • Universal input model uses FDT configuration software (and CBX200 interface) • CE, cULus, cFMus Class 1 Div. 2 and Class 1 Zone 2 ATEX, IECEx Zone 2, DNV, GL approvals • Ambient temperature range typically -13˚F to 158˚F (-25˚C to 70˚C) Weidmuller, United States 821 Southlake Blvd. Richmond, Virginia 23236 Telephone: (800) 849-9343 Facsimile: (804) 379-2593 Email: [email protected] Website: www.weidmuller.com ACT20M Signal Isolation and Conversion Universal input converter ACT20M-UI-AO-S • Isolating and converting of temperature signals and DC signals • Configuration using FDT/DTM software • Optional power supply via the DIN-railbus • 3 way isolation 4 3 I, U, R IN 2 5 I, U 6 OUT 7 1 82 83 Supply 8 Supply Technical data Input Sensor Thermocouples: B, E, J, K, L, LR, N, R, S, T, U, W3, W5 RTD: PT100, PT1000, Ni120, Ni100, Ni1000 2/3/4 wire 10 Ω…10 k Ω 0(4)...20 mA 0(2)...10 V, 0(1)...5 V > 10 MΩ < 150 Ω > 15 V DC at 20 mA Potentiometer/Resistance Input current Input voltage Input resistance, voltage Input resistance, current input Sensor supply Output Output current Output voltage Load resistance, current Load resistance, voltage General data Supply voltage Power consumption 0(4)…20 mA 0(2)…10 V < 600 Ω > 10 k Ω Temperature coefficient Insulation coordination Insulation voltage Rated voltage Pollution degree Overvoltage category Approvals Dimensions Length x width x height Clamping range (nominal / min. / max.) Note mm mm2 + – 3 5 U, I, ϧ 6 U, I 2 Power 1 In + – 3 7 8 4 5 U, I, ϧ 6 U, I 2 Power 1 7 8 + – Out 1 + Power 24 V – + – PLC mA passive Out 1 + PLC mA passive Power 24 V – ACT20M-UI-AO-S + 4-wire V active 4 3 In – 5 U, I, ϧ 6 U, I 2 2.5 kV 300 V 2 II 1 cULus 61010-1, cFMus Div.2, ATEX zone 2, IECEx Zone 2, DNV, GL 3 Power TC In + – 114.3 x 6.1 x 112.5 2.5 / 0.5 / 2.5 7 8 4 Type ACT20M-UI-AO-S Qty. 1 Part No. 1176030000 Note Accessories Marker USB interface 2 In 5 U, I, ϧ 6 U, I 2 Power 1 7 8 + – Out 1 + Power 24 V – + – PLC mA passive Out 1 + PLC mA passive Power 24 V – ACT20M-UI-AO-S Ordering data Note 4-wire mA active 2-wire mA passive 24 V DC ± 30 % 0.4 W (24 V supply / Passive input / 20 mA input & output / 100 Ω load) -25 °C…+70 °C -40 °C…+85 °C < 0.1 % span (DC, RTD) < 0.2 % + CJ error (TC) < 0.01 % /K Ambient temperature (operational) Storage temperature Accuracy ACT20M-UI-AO-S 4 Type MF 5/7.5 MC NEUTRAL CBX200 USB Qty. DIN-rail bus, refer to accessories page Part No. 1877680000 8978580000 RTD Sense + 4 R+ 3 R– 2 Sense – 1 5 U, I, ϧ 6 U, I Power 7 8 + – + – Out 1 PLC mA passive Power 24 V ACT20M Signal Isolation and Conversion Signal splitter ACT20M-CI-2CO-S ACT20M-AI-2AO-S • Isolating, converting and splitting DC signals • Configured using DIP switch • Optional power supply via the DIN-rail bus • 4 way isolation I IN I OUT 2 4 5 3 6 2 1 7 82 83 8 I OUT 1 Supply I, U IN 4 5 3 6 I, U OUT 2 2 1 Supply 7 82 83 I, U OUT 1 Supply 8 Supply Technical data Input Input current Input voltage 0(4)…20 mA – 0(4)…20 mA 0(2)…10 V 0(1)…5 V < 75 Ω > 500 k Ω > 17 V DC at 20 mA Input resistance, current input Load resistance, voltage Sensor supply Output Output current Output voltage < 75 Ω – – Load resistance, current Load resistance, voltage General data Supply voltage Power consumption < 300 Ω / channel ≥ 10 k Ω 0(4)…20 mA 0(2)…10 V 0(1)…5 V < 300 Ω / channel > 10k Ω / channel 24 V DC ± 30 % 24 V DC ± 30 % 0.4 W (24 V supply / Passive input / 20 mA input & output / 100 Ω load) 0.4W (24 V supply / Passive input / 20 mA input & output / 100 Ω load) Ambient temperature (operational) Storage temperature Accuracy Temperature coefficient Cut-off-frequency Insulation coordination Insulation voltage Rated voltage Pollution degree Overvoltage category Approvals -25 °C…+70 °C -40 °C…+85 °C < 0.05 % of measurement range < 0.01 % /K 100 Hz -25 °C…+70 °C -40 °C…+85 °C < 0.05 % of measurement range < 0.01 % /K 100 Hz 2.5 kV 300 V 2 II 2.5 kV 300 V 2 II cULus 61010-1, cFMus Div.2, ATEX zone 2, IECEx Zone 2, DNV, GL cULus 61010-1, cFMus Div.2, ATEX zone 2, IECEx Zone 2, DNV, GL 114.3 x 6.1 x 112.5 2.5 / 0.5 / 2.5 114.3 x 6.1 x 112.5 2.5 / 0.5 / 2.5 Dimensions Length x width x height Clamping range (nominal / min. / max.) 0(4)…20 mA – mm mm2 Note Ordering data Note Accessories Marker Note Type ACT20M-CI-2CO-S Qty. 1 Part No. 1175990000 Type ACT20M-AI-2AO-S Qty. 1 Part No. 1176020000 Type MF 5/7.5 MC NEUTRAL Qty. Part No. 1877680000 Type MF 5/7.5 MC NEUTRAL Qty. Part No. 1877680000 DIN-rail bus, refer to accessories page DIN-rail bus, refer to accessories page 3 ACT20M Signal Isolation and Conversion Converters for DC mA and Volts ACT20M-AI-AO-S ACT20M-AI-AO-E-S • Isolating and converting DC signals • DIP switch for range changes without re-calibration • Optional power supply via the DIN-rail-bus • 3 way isolation • Choice of active or passive mA input (“E“ model is not hazardous location approved) 4 I, U IN 5 3 I, U OUT 6 2 82 83 5 3 7 1 Supply 82 8 Supply I, U OUT 6 2 7 1 4 I, U IN 83 Supply 8 Supply Technical data Input Input current Input voltage Input resistance, current input Input resistance, voltage Sensor supply Output Output current Output voltage Load resistance, current Load resistance, voltage General data Supply voltage Power consumption 0(4)…20 mA 0(2)…10 V; 0(1)…5 V < 75 Ω > 500 k Ω – 0(4)…20 mA 0(2)…10 V; 0(1)…5 V <Input 600 Ω > 10 k Ω 0(4)…20 mA 0(2)…10 V; 0(1)…5 V <Input 600 Ω > 10 k Ω Switch 1 2 3 4 ◼ ◼ ◼ ◼ 0 …V20DC mA± 30 % 24 ◼ ◼ ◼ 4 … 20 0.4 W m(24 V supply / Passive input / 20◼mA input & ◼ ◼ ◼ ◼ 0 … 10 V/ 100 Ω load) output ◼ ◼ ◼ ◼ 2 …°C…+70 10 V -25 °C ◼ ◼ ◼ ◼ 0 …°C…+85 5V -40 °C ◼ ◼ …5 V % of measurement◼ range◼ <10.05 ◼ ◼ ◼ ◼ ... 20 mA loop <00.01 % /K ◼ ◼ ◼ ◼ 4 ... 20 100 HzmA loop Ambient temperature (operational) Storage temperature Accuracy Temperature coefficient Cut-off-frequency Insulation coordination Insulation voltage Rated voltage Pollution degree Overvoltage category Approvals Dimensions Length x width x height Clamping range (nominal / min. / max.) 0(4)…20 mA 0(2)…10 V; 0(1)…5 V < 75 Ω > 500 k Ω > 17 V DC at 20 mA mm mm2 2.5 kV Switch 300 V1 Output 2 5 6 7 II ◼ ◼ ◼ 0 … 20 mA ◼ ATEX ◼ zone ◼ cULus cFMus Div.2, 2, IECEx Zone 4 … 2061010-1, m ◼ ◼ ◼ 2,0 DNV, … 10 VGL ◼ ◼ ◼ 2 … 10 V ◼ ◼ ◼ 114.3 0 … 5 Vx 6.1 x 112.5 ◼ ◼ ◼ 2.5 1 …5/ 0.5 V / 2.5 1 2 3 4 ◼ ◼ ◼ ◼ 0 … 20 mA 24 V DC ± 30 % ◼ ◼ ◼ ◼ 4 … 20 m 0.4 W (24 V supply / Passive input / 20◼mA input & ◼ ◼ ◼ 0 … 10 V output / 100 Ω load) ◼ ◼ ◼ ◼ 2 … 10 V 0 °C…+70 °C ◼ ◼ ◼ ◼ 0…5V -40 °C…+85 °C ◼ ◼ ◼ ◼ 1 …5 V < 0.2 % of measurement ◼range ◼ ◼ ◼ 0 ... 20 mA loop < 0.015 % /K ◼ ◼ ◼ ◼ 4 ... 20 mA loop 100 Hz 2.5 kV Output 300 V1 2 5 II ◼ 0 … 20 mA ◼ 4 … 20 m cULus DNV, GL◼ 0 … 10 61010-1, V ◼ 2 … 10 V ◼ 0 … 5 Vx 6.1 x 112.5 114.3 ◼ 1 …5/ 0.5 V / 2.5 2.5 ACT20M-AI-AO-S In + – 4 3 6 U, I U, I Power 1 4-wire V, mA active 4 + – 3 7 8 4 5 6 U, I 1 Marker Note In Type ACT20M-AI-AO-S 2 Accessories 6 7 ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ACT20M-AI-AO-E-S 5 2 Ordering data Switch ◼ = on ◼ = off ◼ = on ◼ = off 2-wire mA passive Switch Type MF 5/7.5 MC NEUTRAL U, I Power Qty. 71 8 Qty. DIN-rail bus, refer to accessories page + – Out 1 + Power 24 V – + – + – PLC V, mA passive Out 1 PLC V, mA passive 4-wire V, mA active In + – 4 3 5 6 U, I U, I 2 1 Power 7 8 + – + – Out 1 PLC V, mA passive Power 24 V Part No. 1176000000 Power Type ACT20M-AI-AO-E-S Qty. 1 Part No. 1176010000 Part No. 1877680000 Type MF 5/7.5 MC NEUTRAL Qty. Part No. 1877680000 24 V DIN-rail bus, refer to accessories page ACT20M Signal Isolation and Conversion ILP and OLP isolators ACT20M-CI-CO-ILP-S ACT20M-CI-CO-OLP-S • Isolation of DC mA signals • Takes power from the input loop (ILP) or output loop (OLP) • Available as either single-channel or double-channel version • 2 way isolation I IN 1 I IN 2 4 5 3 6 2 7 1 8 I OUT 1 I IN 1 I OUT 2 I IN 2 4 5 3 6 2 7 1 8 I OUT 1 I OUT 2 Technical data Input Input current Input resistance, current input Output Output current Load resistance, current General data Power consumption Ambient temperature (operational) Storage temperature Accuracy Temperature coefficient Cut-off-frequency Insulation coordination Insulation voltage Rated voltage Pollution degree Overvoltage category Approvals Dimensions Length x width x height Clamping range (nominal / min. / max.) 0(4)…20 mA < 65 Ω at 25 °C 0(4)…20 mA typ. < 125 Ω 0(4)…20 mA < 600 Ω 4 - 20 mA < 600 Ω 30 mW per channel - from input loop -25 °C…+70 °C -40 °C…+85 °C < 0.1 % of measurement range < 0.01 % /K 100 Hz 55 mW per channel - from output loop -25 °C…+70 °C -40 °C…+85 °C < 0.1 % of measurement range < 0.01 % /K 100 Hz 2.5 kV 300 V 2 II 2.5 kV 300 V 2 II ACT20M-CI-CO-ILP-S 4-wire cULus 61010-1,+ mA In – 2, DNV, active GL mm mm2 4 cFMus 3 5 PLC Div.2, ATEX zone + 2, IECEx Zone 6 I 2 – Out mA passive 7 114.3 x 6.1 x 112.5 2.5 / 0.5 / 2.5 1 I ACT20M-CI-CO-OLP-S 4 5 2-wire PLC cULus 61010-1,+ cFMus Div.2, ATEX zone + 2, IECEx Zone mA mA In Out 2, DNV, – 3 passiveGL active 6 – I 2 114.3 x 6.1 x 112.5 1 2.5 / 0.5 / 2.5 8 ACT20M-2CI-2CO-ILP-S 4-wire mA active In 1 4-wire mA active In 2 + – + – 4 3 2 I 6 7 I 1 I 8 ACT20M-2CI-2CO-OLP-S 5 I 7 I 8 + – + – Out 1 Out 2 PLC mA passive 2-wire mA passive In 1 PLC mA passive 2-wire mA passive In 2 + – + – 4 3 2 5 I I 7 I 1 6 I 8 + – + – Out 1 PLC mA active Out 2 PLC mA active Ordering data Single-channel version Double-channel version Type ACT20M CI-CO-ILP-S ACT20M 2CI-2CO-ILP-S Qty. 1 1 Part No. 1176070000 1176080000 Type ACT20M- CI-CO-OLP-S ACT20M-2CI-2CO-OLP-S Qty. 1 1 Part No. 1176040000 1176050000 Marker Type MF 5/7.5 MC NEUTRAL Qty. Part No. 1877680000 Type MF 5/7.5 MC NEUTRAL Qty. Part No. 1877680000 Accessories 5 ACT20M Signal Isolation and Conversion DC isolator ACT20M-CI-CO-S • Isolating DC signals • Optional power supply via the DIN-rail-bus • 3 way isolation I IN 4 5 3 I OUT 6 2 7 1 82 83 8 Supply Supply Technical data Input Input current Load resistance, current input Output Output current Load resistance, current General data Supply voltage Power consumption 0(4)…20 mA < 75 Ω 0(4)…20 mA < 600 Ω 2.5 kV 300 V 2 II cULus 61010-1, cFMus Div.2, ATEX zone 2, IECEx Zone 2, DNV, GL mm mm2 114.3 x 6.1 x 112.5 mm 2.5 / 0.5 / 2.5 mm² Note Ordering data Type ACT20M-CI-CO-S Qty. 1 Part No. 1175980000 Type MF 5/7.5 MC NEUTRAL Qty. Part No. 1877680000 Note Accessories Marker Note 6 In + – 4 3 5 6 I I 2 24 V DC ± 30 % 0.4 W (24 V supply / Passive input / 20 mA input & output / 100 Ω load) -25 °C…+70 °C -40 °C…+85 °C < 0.05 % of measurement range < 0.01 % span/K 100 Hz Ambient temperature (operational) Storage temperature Accuracy Temperature coefficient Cut-off-frequency Insulation coordination Insulation voltage Rated voltage Pollution degree Overvoltage category Approvals Dimensions Length x width x height Clamping range (nominal / min. / max.) ACT20M-CI-CO-S 4-wire mA active DIN-rail bus, refer to accessories page 1 Power 7 8 + – + – Out 1 PLC mA passive Power 24 V ACT20M Signal Isolation and Conversion Temperature transmitter ACT20M-RTCI-CO-OLP-S ACT20M-RTI-CO-EOLP-S • Choice of isolating or non-isolating converters for J or K thermocouples and RTDs. • Hundreds of min/max range combinations • Configuration via DIP switches • Power supplied from the output loop • 2-way isolation (OLP-S model only) • Output is linear with temperature + PT 100 TC + Optional external – CJC 4 5 3 6 I 8 V DC...35 V DC PLC PT 100 2 1 4 5 3 6 I 8 V DC...35 V DC PLC 2 1 Technical data Input Sensor Input measurement range Temperature input range Output Output current Load Resistance Wire break detection General data Configuration Supply voltage Power consumption Accuracy Temperature coefficient Galvanic isolation Step response time Ambient temperature (operational) Insulation coordination Insulation voltage Rated voltage Pollution severity Surge voltage category Approvals Dimensions Clamping range (nominal / min. / max.) Depth x width x height mm² mm PT100 / 2-/3-/4-wire, Thermocouple acc. to IEC 584, type: J, Thermocouple acc. to IEC 584, type: K PT100 -200…+850 °C, Thermocouple type J -100… +1200 °C, Thermocouple type K -200…+1370 °C (internal or external CJC) Selectable by DIP Switch PT100 / 2-/3-/4-wire 4...20 mA, 20…4 mA <600 Ω 3.5 mA ⁄ 23 mA ⁄ none Selectable by DIP Switch 4...20 mA, 20…4 mA <600 Ω 3.5 mA ⁄ 23 mA ⁄ none Selectable by DIP Switch DIP switch 8...35 V DC Loop powered ca. 1 W absolute accuracy: < ±0.05 % of the measurement range, RTD (PT100) Basic accuracy: < ±0.1 °C of the measurement range, TC (J,K) Basic accuracy: < ±0.5 °C of the measurement range RTD (PT100) ≤ 0.01 % of the measurement range ⁄ °C or 0.02 °C ⁄ °C‘, TC (J,K) 0.1 °C ⁄ °C 2-way isolator ≤ 30 ms / ≤ 300 ms Selectable by DIP Switch -25...+70 °C DIP switch 8...35 V DC Loop powered ca. 1 W absolute accuracy: < ±0.1 % of the measurement range, Basic accuracy: < ±0.2 °C of the measurement range 2.5 kVeff 300 Veff N/A 2 II 2 II cULus; FMEX; IECEXKEM; KEMAATEX; DETNORVER; GL cULus; FMEX; IECEXKEM; KEMAATEX; DETNORVER; GL 2.5 / 0.5 / 2.5 114.3 / 6.1 / 112.5 2.5 / 0.5 / 2.5 114.3 / 6.1 / 112.5 PT100 -200…+850 °C Selectable by DIP Switch RTD (PT100) ≤ 0.01 % of the measurement range ⁄ °C or 0.02 °C ⁄ °C Without isolation ≤ 30 ms / ≤ 300 ms Selectable by DIP Switch -25...+70 °C Note Ordering data Type ACT20M-RTCI-CO-OLP-S Qty. 1 Part No. 1435590000 Type ACT20M-RTI-CO-EOLP-S Qty. 1 Part No. 1435610000 Note 7 ACT20M Signal Isolation and Conversion Temperature transmitter ACT20M-RTI-AO-S ACT20M-RTI-AO-E-S • Choice of isolating or non-isolating converters for RTDs. • Hundreds of min/max range combinations • Optional Power Rail accessory simplifies jumpering and saves wiring time. • Configuration via DIP switches • 3-way isolation (AO-S model only) PT 100 4 5 3 6 2 7 1 82 83 8 I, V PLC PT 100 Supply 4 5 3 6 2 7 1 8 I, V OUT 1 Supply Supply Technical data Input Sensor Input measurement range Temperature input range Output Output current Output voltage load impedance current load impedance voltage Wire break detection General data Configuration Supply voltage Power consumption Accuracy Galvanic isolation Temperature coefficient Step response time Ambient temperature (operational) Insulation coordination Insulation voltage PT100 / 2-/3-/4-wire PT100 -200…+850 °C Selectable by DIP Switch PT100 / 2-/3-/4-wire PT100 -200…+850 °C Selectable by DIP Switch 0...20 mA, 4...20 mA Selectable by DIP Switch 0(1)...5 V, 0(2)...10 V Selectable by DIP Switch ≤ 600 Ω ≥ 10 kΩ 3.5 mA ⁄ 23 mA ⁄ none Selectable by DIP Switch 0...20 mA, 4...20 mA Selectable by DIP Switch 0(1)...5 V, 0(2)...10 V Selectable by DIP Switch ≤ 600 Ω ≥ 10 kΩ 3.5 mA ⁄ 23 mA ⁄ none Selectable by DIP Switch DIP switch 24 V DC ± 30 % 1W absolute accuracy: < ±0.05 % of the measurement range, Basic accuracy: < ±0.1 % of the measurement range 3-way isolator ≤0.01 % of the measurement range °C or 0.02 °C ⁄ °C ≤ 30 ms / ≤ 300 ms Selectable by DIP Switch -25...+70 °C DIP switch 24 V DC ± 30 % 1W absolute accuracy: < ±0.1 % of the measurement range 2.5 kVeff N/A N/A Without isolation ≤0.01 % of the measurement range °C or 0.02 °C ⁄ °C ≤ 30 ms / ≤ 300 ms Selectable by DIP Switch -25...+70 °C Rated voltage 300 Veff Pollution severity Surge voltage category Approvals 2 II 2 II cULus; FMEX; IECEXKEM; KEMAATEX; DETNORVER; GL cULus; FMEX; IECEXKEM; KEMAATEX; DETNORVER; GL 2.5 / 0.5 / 2.5 114.3 / 6.1 / 112.5 2.5 / 0.5 / 2.5 114.3 / 6.1 / 112.5 Dimensions Clamping range (nominal / min. / max.) Depth x width x height mm² mm Note Ordering data Type ACT20M-RTI-AO-S Note 8 Qty. 1 Part No. 1375510000 Type ACT20M-RTI-AO-E-S Qty. 1 Part No. 1375520000 ACT20M Signal Isolation and Conversion Temperature transmitter ACT20M-TCI-AO-S ACT20M-TCI-AO-E-S • Choice of isolating or non-isolating converters for J or K thermocouples • Hundreds of min/max range combinations • Optional Power Rail accessory simplifies jumpering and saves wiring time. • Configuration via DIP switches • 3-way isolation (AO-S model only) + TC + Optional external – CJC 4 5 3 6 2 7 1 82 83 8 I, V + PLC TC + Supply Optional external – CJC 4 5 3 6 2 7 1 8 I, V OUT Supply Supply Technical data Input Sensor Input measurement range Temperature input range Output Output current Output voltage load impedance current load impedance voltage Wire break detection General data Configuration Supply voltage Power consumption Accuracy Galvanic isolation Temperature coefficient Step response time Ambient temperature (operational) Insulation coordination Insulation voltage Rated voltage Pollution severity Surge voltage category Approvals Dimensions Clamping range (nominal / min. / max.) Depth x width x height mm² mm Thermocouple (Type J, K) Thermocouple type J -100…+1200 °C, Thermocouple type K -200…+1370 °C (internal or external CJC) Selectable by DIP Switch Thermocouple (Type J, K) Thermocouple type J -100…+1200 °C, Thermocouple type K -200…+1370 °C (internal or external CJC) Selectable by DIP Switch 0...20 mA, 4...20 mA Selectable by DIP Switch 0(1)...5 V, 0(2)...10 V Selectable by DIP Switch ≤ 600 Ω ≥ 10 kΩ 3.5 mA ⁄ 23 mA ⁄ none Selectable by DIP Switch 0...20 mA, 4...20 mA Selectable by DIP Switch 0(1)...5 V, 0(2)...10 V Selectable by DIP Switch ≤ 600 Ω ≥ 10 kΩ 3.5 mA ⁄ 23 mA ⁄ none Selectable by DIP Switch DIP switch 24 V DC ± 30 % ca. 1 W absolute accuracy: < ±0.05 % of the measurement range, TC (J,K) Basic accuracy: < ±0.5 °C of the measurement range 3-way isolator < 0.1 % / °C ≤ 30 ms / ≤ 300 ms Selectable by DIP Switch -25...+70 °C DIP switch 24 V DC ± 30 % ca. 1 W absolute accuracy: < ±0.1 % of the measurement range, Basic accuracy: < ±1 °C 2.5 kVeff 300 Veff 2 II N/A N/A 2 II cULus; FMEX; IECEXKEM; KEMAATEX; DETNORVER; GL cULus; FMEX; IECEXKEM; KEMAATEX; DETNORVER; GL 2.5 / 0.5 / 2.5 114.3 / 6.1 / 112.5 2.5 / 0.5 / 2.5 114.3 / 6.1 / 112.5 Without isolation ≤ 0.01 % / °C ≤ 30 ms / ≤ 300 ms Selectable by DIP Switch -25...+70 °C Note Ordering data Type ACT20M-TCI-AO-S Qty. 1 Part No. 1375480000 Type ACT20M-TCI-AO-E-S Qty. 1 Part No. 1375500000 Note 9 ACT20M Signal Isolation and Conversion Bipolar converters ACT20M-BAI-AO-S ACT20M-BAI-2AO-S • For use with center-zero sensors, e.g. actuator position control, or bi-directional flow monitoring. • DIP switches simplify configuration • Conversion choices: bipolar in/unipolar out, or bipolar in/2x unipolar out. • Optional Power Rail accessory simplifies jumpering and saves wiring time. ± I, ± V IN 4 5 3 82 83 I, V OUT 1 ± I, ± V IN 4 5 6 3 6 7 2 8 OUT 2 Supply 1 I, V Supply 7 82 83 8 I, V OUT 1 Supply Supply Technical data Input Input current Input voltage Input resistance, voltage Input resistance, current inputs Output Cut-off frequency (-3 dB) load impedance voltage Number of outputs load impedance current Output voltage, note Output current General data Accuracy Configuration Galvanic isolation Mounting rail Power consumption Power consumption, max. Step response time Supply voltage Temperature coefficient Type of connection Insulation coordination EMC standards Galvanic isolation Insulation voltage Pollution severity Rated voltage Standards Surge voltage category Approvals Approvals ROHS Dimensions Depth x width x height (mm) -10 mA…0…+10 mA, -20 mA…0…+20 mA -5 V…0…+5 V, -10 V…0…+10 V Selectable by DIP Switch ≥ 1 MΩ 50 Ω at 20 mA -10 mA…0…+10 mA, -20 mA…0…+20 mA -5 V…0…+5 V, -10 V…0…+10 V Selectable by DIP Switch ≥ 1MΩ 50 Ω at 20 mA ≥ 100 Hz, 10 Hz Selectable by DIP Switch ≥ 10 kΩ 1 ≤ 600 Ω 0(2)...10 V, 0(1)...5 V Selectable by DIP Switch 0...20 mA, 4...20 mA Selectable by DIP Switch ≥ 100 Hz, 10 Hz Selectable by DIP Switch ≥ 10 kΩ 2 2 x 300 Ω 0(2)...10 V, 0(1)...5 V Selectable by DIP Switch 0...20 mA, 4...20 mA Selectable by DIP Switch < 0.05 % of measuring range DIP switch 3-way isolator; TS 35 Typ. 400 mW 0.8 W ≤ 7 ms, ≤ 100 ms, Selectable by DIP Switch 24 V DC ± 30 % < 0.01% of span/°C (TU) Screw connection < 0.05 % of measuring range DIP switch 4-way isolator; TS 35 Typ. 400 mW 0.8 W ≤ 7 ms, ≤ 100 ms, Selectable by DIP Switch 24 V DC ± 30 % < 0.01% of span/°C (TU) Screw connection EN 61326-1 3-way isolator; 2.5 kVeff EN 61326-1 4-way isolator; 2.5 kVeff 2 300 Veff 2 300 Veff DIN EN 61010-1, DIN EN 60079 II DIN EN 61010-1, DIN EN 60079 II cULus, DNV, FM, IECEx, Ex Conform cULus, DNV, FM, IECEx, Ex Conform 114.3 x 6.1 x 112.5 114.3 x 6.1 x 112.5 Note Ordering data Note 10 Type ACT20M-BAI-AO-S Qty. 1 Part No. 1375450000 Type ACT20M-BAI-2AO-S Qty. 1 Part No. 1375470000 ACT20M Signal Isolation and Conversion Rail bus accessories CH20M BUS-PROFIL TS35x7.5/1000 CH20M BUS-PROFIL TS35x15/1000 CH20M BUS 4.50/05 AU/1000 • Support section for TS35 x 7.5 • Length: 250, 500 or 750 mm • Support section for TS35 x 15 • Length: 250, 500 or 750 mm • Bus PCB for use on TS35 x 7.5 and TS 35 x 15 • Length: 250, 500 or 750 mm • Five conductor paths, gold plated • Electrical rating: 63 V AC, 5 A/conductor path Support section for bus PCB Ordering data Type CH20M BUS-PROFIL TS35x7.5/250 CH20M BUS-PROFIL TS35x7.5/500 CH20M BUS-PROFIL TS35x7.5/750 Qty. Part No. 10 1248150000 10 1248160000 5 1248170000 Support section for bus PCB Ordering data Type CH20M BUS-PROFIL TS35x15/250 CH20M BUS-PROFIL TS35x15/500 CH20M BUS-PROFIL TS35x15/750 Qty. Part No. 5 1248180000 5 1248190000 5 1248210000 Bus PCB Ordering data Type CH20M BUS 4.50/ 05 AU/250 CH20M BUS 4.50/ 05 AU/500 CH20M BUS 4.50/ 05 AU/750 Qty. Part No. 10 1248220000 10 1248230000 5 1248240000 CH20M BUS-ADP TS35/1000 CH20M BUS-AP LI TS35x7.5 & 15 CH20M BUS-AP RE TS35x7.5 & 15 • Cover plate for rail bus • Length: 250, 500 or 750 mm • End plate for rail bus • Fits on TS35 x 7.5 and TS 35 x 15 • Left • End plate for rail bus • Fits on TS35 x 7.5 and TS 35 x 15 • Right Cover plate Ordering data Type Qty. End plate Part No. CH20M BUS-ADP TS35/250 10 1248250000 CH20M BUS-ADP TS35/500 10 1248260000 CH20M BUS-ADP TS35/750 5 1248270000 Ordering data Type CH20M BUS-AP LI TS35x7.5 & 15 Ordering data Qty. Part No. 50 1193160000 SET CH20M BUS 250MM TS 35X15 SET CH20M BUS 250MM TS 35X7.5 • S ET consists of one each of • S ET consists of one each of Set CH20M BUS 4.50/05 AU/250 CH20M BUS-ADP TS 35/250 CH20M BUS-ADP TS 35/250 CH20M BUS-AP LI TS 35X7.5 & 15 CH20M BUS-AP LI TS 35X7.5 & 15 CH20M BUS-AP RE TS 35X7.5 & 15 CH20M BUS-AP RE TS 35X7.5 & 15 CH20M BUS-PROFIL TS 35X15/250 CH20M BUS-PROFIL TS 35X7.5/250 Type Qty. SET CH20M BUS 250MM TS 1 35X15 Part No. 1335150000 Type CH20M BUS-AP RE TS35x7.5 & 15 Qty. Part No. 50 1193170000 Set CH20M BUS 4.50/05 AU/250 Ordering data End plate Ordering data Type Qty. SET CH20M BUS 250MM TS 1 35X7.5 Part No. 1335140000 11 ACT20M Signal Isolation and Conversion Output-current loop-powered • Galvanic isolation • Very low power consumption • Input range selected via DIP switch • No calibration necessary OLP UL Class I, Div. 2 U/I I Technical data Input Input voltage Input resistance, voltage/current Input current Rated current Output Output current Output signal limit Load impedance, voltage/current Cut-off frequency (-3 dB) General data Configuration Supply voltage Ambient temperature Default setting Accuracy Temperature coefficient Step response time Approvals Insulation coordination Standards EMC standards Rated voltage Impulse withstand voltage Insulation voltage Setting options/switch position 0...5V: 210 kΩ; 0...10V: 430 kΩ / 51 Ω 0(4)...20 mA 40 mA 4...20 mA (current loop) Approx. 31 mA / RL = (UB-12 V) / 20 mA z.B. 600 Ω at 24 V 10 Hz/ 100 Hz switchable DIP switch min. 12 V DC/ max. 30 V DC 0 °C...+55 °C 0...20mA, 10 Hz 0.2% of measuring range final value ≤ 150 ppm/K < 10 Hz: 80 ms; 100 Hz: 50 ms CE; cULus n 0 … 20 mA ◼ 4 … 20 mA ◼ 0…5V 0 … 10 V n Transmission frequency 10 Hz n 100 Hz n ◼ n mm² mm 4 n n n n n ◼ ◼ n ◼ n n n n ◼ n n n 24V DC 24 V DC 230 V AC 1 3 WAVE ANALOGUE OLP 8543720000/8543730000 Sensor Part No. 8543720000 ~ 7 8 9 4 ... 20mA 0...10V Ordering data Screw connection n 230 V AC 2 Qty. 1 SW 1 3 = on = off ~ 2.5 / 0.5 / 2.5 92.4 / 17.5 / 112.4 Type WAS5 OLP 2 Example of application III 2 ≥ 5.5 mm Dimensions Clamping range (nominal / min. / max.) Length x width x height Note 12 1 DIN EN 50178, DIN EN 61000-4-2 EN 55011, EN 61000-6 300 V 4 kV 4 kVeff / 5 s Surge voltage category Pollution severity Clearance & creepage distances Note Input RL SPS ACT20M Signal Isolation and Conversion Thermal converter type: K,J,T,E,N,R,S,B PRO Thermo Select of thermocoupler SW1 Typ 1 2 3 UL Class I, Div. 2 • 3-way isolation • Internal cold-junction compensation • Power supply can be cross-connected using plug-in jumpers • Suitable for insulated and uninsulated thermocouples • W AVETOOL software helps with configuration, download at www.weidmuller.com K J T E N R S B ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ U/I J Selection of temperature span SW2 Span 1 2 3 4 5 VC Technical data Input Sensor Temperature input range Output Output voltage / Output current Load impedance, voltage/current Offset current / Offset voltage Line resistance in measuring circuit Wire break detection Fine adjustment Status indicator Thermo element (IEC 584) type: K,J,T,E,N,R,S,B -200...+1820 °C 0...10 V / 0(4)...20 mA ≥ 1 kΩ / ≤ 600 Ω max. 100 µA / max. 0.05 V 50 Ω LED flashing (output value: > 20 mA, >10 V) ± 5% (switchable) Module active: LED on/ wire breakage: LED flashing/ Error: LED off General data Configuration Supply voltage Power consumption Step response time Current-carrying capacity of cross-connect. Ambient temperature Storage temperature Default setting DIP switch 24 V DC ± 25 % 800...850...950 mW at IOUT = 20 mA without filter: max. 1.4 s; with filter: max. 7.5 s ≤2A 0 °C...+55 °C -20 °C...+85 °C Type K; 0...1000°C; 4...20mA; filter: off; man. calibration: off CE; cULusEX; GL Approvals Insulation coordination Standards EMC standards Rated voltage Impulse withstand voltage Insulation voltage DIN EN 50178, DIN EN 61000-4-2 EN 55011, EN 61000-6 300 4 kV 2 kVeff / 5 s Surge voltage category Pollution severity Clearance & creepage distances mm² mm 2.5 / 0.5 / 2.5 92.4 / 17.5 / 112.4 Ordering data Screw connection Type WAS5 PRO Thermo Qty. 1 100 °C 150 °C 200 °C 250 °C 300 °C 350 °C 400 °C 450 °C 500 °C 550 °C 600 °C 650 °C 700 °C 750 °C 800 °C 850 °C 900 °C 950 °C 1000 °C 1050 °C 1100 °C 1150 °C 1200 °C 1250 °C 1300 °C 1350 °C 1400 °C 1450 °C 1500 °C 1600 °C 1700 °C 1800 °C ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ Accuracy III 2 ≥ 3 mm Dimensions Clamping range (nominal / min. / max.) Length x width x height Note Note ◼ Part No. 8560720000 K -200 °C …-150 °C -150 °C …1200 °C 1200 °C …1372 °C J -200 °C …-150 °C -150 °C …1200 °C T -200 °C …-150 °C -150 °C … 400 °C E -200 °C …-150 °C -150 °C …1000 °C N -200 °C …-150 °C -150 °C …1300 °C R -50 °C … 200 °C 200 °C …1760 °C S -50 °C … 200 °C 200 °C …1760 °C B 50 °C … 250 °C 250 °C … 500 °C 500 °C …1820 °C Selection of minimum temperature SW1 ϑ min 1 2 3 4 0 °C – 10 °C – 20 °C – 30 °C – 40 °C – 50 °C – 100 °C – 150 °C – 200 °C + 50 °C + 100 °C + 150 °C + 200 °C + 250 °C + 500 °C Special range ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ ◼ Selection of output Switch 2 Output 6 7 ◼ ◼ 0 ... 10 V ◼ ◼ 0 ... 20 V ◼ ◼ 4 ... 20 V Switching on the manual fine adjustment SW 2 man. adjust. 6 ◼ off ◼ on Switching on the filter function SW 2 Filter off on ◼ ◼ 8 ◼ ◼ = on = off ± (5K + 0.1 % of set range) ± (3K + 0.1 % of set range) ± (4K + 0.1 % of set range) ± (4K + 0.1 % of set range) ± (3K + 0.1 % of set range) ± (5K + 0.1 % of set range) ± (3K + 0.1 % of set range) ± (4K + 0.1 % of set range) ± (3K + 0.1 % of set range) ± (6K + 0.1 % of set range) ± (3K + 0.1 % of set range) ± (10K + 0.1 % of set range) ± (6K + 0.1 % of set range) ± (10K + 0.1 % of set range) ± (6K + 0.1 % of set range) ± (25K + 0.1 % of set range) ± (10K + 0.1 % of set range) ± (6K + 0.1 % of set range) 13 ACT20M Signal Isolation and Conversion RTD signal isolator/converter • Universally adjustable via DIP switch • 3-way isolation • Linearisation • Power supply can be cross-connected using plug-in jumpers • W AVETOOL software helps with configuration,download at www.weidmuller.com RTD J,R PRO RTD UL Class I, Div. 2 U/I VC Technical data Input Sensor PT100/2-/3-/4-wire, Ni100/2-/3-/4-wire, potentiometer: min. 0–100 Ω, max. 0–100 kΩ, Resistance: 0–450 Ω configurable Temperature input range Output Output current / Output voltage Offset current / Offset voltage Load impedance, voltage/current Wire break detection Fine adjustment 0(4)...20 mA / 0...10 V max. 100 µA / max. 0.05 V ≥ 1 kΩ / ≤ 600 Ω LED flashing (output value: > 20 mA, >10 V) ≥ ± 5 %, Version 1 and later: ≥ 12.5 % / potentiometer: 12.5%...25% Module active: LED on/ wire breakage: LED flashing/ Error: LED off Status indicator General data Configuration Supply voltage Power consumption Step response time DIP switch, Potentiometer 24 V DC ± 25 % 830...880...980mW at IOUT = 20 mA fast/slow: 2-/3-/4-conductor: 1.2 s/2.2 s; potentiometer: 0.5 s/1.1 s 0 °C...+55 °C CE; cULus; GL Ambient temperature Approvals Insulation coordination Standards EMC standards Rated voltage Impulse withstand voltage Insulation voltage DIN EN 50178, DIN EN 61000-4-2 EN 55011, EN 61000-6 300 V 4 kV 2 kVeff / 5 s Surge voltage category Pollution severity Clearance & creepage distances Dimensions Clamping range (nominal / min. / max.) Length x width x height Note III 2 ≥ 3 mm mm² mm 2.5 / 0.5 / 2.5 92.4 / 17.5 / 112.4 Ordering data Screw connection Note 14 Type WAS5 PRO RTD Qty. 1 Part No. 8560700000 ACT20M Signal Isolation and Conversion PRO RTD Switch position / setting options Choice of inputs Switch 1 Input 1 2 3 PT100 2-wire ■ ■ ■ PT100 3-wire □ ■ ■ PT100 4-wire ■ □ ■ R 2-wire □ □ ■ NI100 2-wire ■ ■ □ NI100 3-wire □ ■ □ NI100 4-wire ■ □ □ Potentiometer □ □ □ ■ = on □ = off Choice of outputs Switch 2 Output 6 7 0...10 V ■ □ 0...5 V ■ ■ 0...20 mA □ □ 4...20 mA □ ■ Choice of step response time Step response time slow fast ϑmin 0 °C -10 °C -20 °C -25 °C -30 °C -40 °C -50 °C -60 °C -70 °C -80 °C -90 °C -100 °C -150 °C -200 °C Choice of minimum input size Switch 1 Rmin Potimin 4 5 6 0Ω 0% ■ ■ ■ 10 Ω 10 % ■ ■ ■ 20 Ω 20 % ■ ■ □ 20 Ω 25 % ■ ■ □ 30 Ω 30 % ■ □ ■ 40 Ω 40 % ■ □ ■ 50 Ω 50 % ■ □ □ 60 Ω 60 % ■ □ □ 70 Ω 70 % □ ■ ■ 80 Ω 80 % □ ■ ■ 90 Ω □ ■ □ 100 Ω □ ■ □ 150 Ω □ □ ■ 200 Ω □ □ ■ Special area T 40 K 50 K 60 K 70 K 80 K 90 K 100 K 110 K 120 K 125 K 130 K 140 K 150 K 160 K 170 K 180 K 190 K 200 K 250 K 300 K 350 K 400 K 450 K 500 K 550 K 600 K 650 K 700 K 750 K 800 K 850 K 900 K □ □ □ Choice of measuring range Switch 2 Poti R 1 2 3 4 20 Ω 20 % ■ ■ ■ ■ 25 Ω 25 % ■ ■ ■ ■ 30 Ω 30 % ■ ■ ■ □ 35 Ω 35 % ■ ■ ■ □ 40 Ω 40 % ■ ■ □ ■ 45 Ω 45 % ■ ■ □ ■ 50 Ω 50 % ■ ■ □ □ 55 Ω 55 % ■ ■ □ □ 60 Ω 60 % ■ □ ■ ■ 62,5 Ω 62,5 % ■ □ ■ ■ 65 Ω 65 % ■ □ ■ □ 70 Ω 70 % ■ □ ■ □ 75 Ω 75 % ■ □ □ ■ 80 Ω 80 % ■ □ □ ■ 85 Ω 85 % ■ □ □ □ 90 Ω 90 % ■ □ □ □ 95 Ω 95 % □ ■ ■ ■ 100 Ω 100 % □ ■ ■ ■ 125 Ω --□ ■ ■ □ 150 Ω --□ ■ ■ □ 175 Ω --□ ■ □ ■ 200 Ω --□ ■ □ ■ 225 Ω --□ ■ □ □ 250 Ω --□ ■ □ □ 275 Ω --□ □ ■ ■ 300 Ω --□ □ ■ ■ 325 Ω --□ □ ■ □ 350 Ω --□ □ ■ □ 375 Ω --□ □ □ ■ 400 Ω --□ □ □ ■ 425 Ω --□ □ □ □ 450 Ω --□ □ □ □ 7 ■ □ ■ □ ■ □ ■ □ ■ □ ■ □ ■ □ ■ 5 ■ □ ■ □ ■ □ ■ □ ■ □ ■ □ ■ □ ■ □ ■ □ ■ □ ■ □ ■ □ ■ □ ■ □ ■ □ ■ □ Switch on the manual fine adjustments S. 1 Man. adjustment 8 off □ on ■ S. 2 8 ■ □ Accuracy, slow/fast step response time PT 100,Ni 100: 0,3 % from measuring range 0,8 % from measuring range < 100 K / 0,3 K / 0,8 K Potentiometer: 0.2 % from end value / 0.3 % Resistance: 0.2 % from end value / 0.3 % Temperature coefficient Measuring range ≥ 200 K 100 K ≤ Measuring range < 200 K 40 K ≤ Measuring range < 100 K ≤ 200 ppm / °C ≤ 250 ppm / °C ≤ 400 ppm / °C Adjustment example for zero and span Temperature adjustment: Output 4…20 mA DIP switch -10 °C…+110 °C Span 75…110 °C Range 120 °C Adjustment range ± 12.5 % Zero –25° C –10° C 95° C 110° C 125° C –5° C Span 5° C 110° C 125° C 140° C Wavetool adjustment tool This service tool enables quick and straightforward configuration of the WAVEANALOG PRO. Internet download: http://www.weidmuller.com 15 ACT20M Signal Isolation and Conversion ACT20 power feed module ACT20M-FEED-IN-PRO-S ACT20-FEED-IN-BASIC-S • Distributes the voltage supply on the busbar • Compatible with Weidmuller‘s CH20 rail bus • Optional backup supply connection • Approved for installation in Ex Zone 2 /Div. 2 • Monitors the supply voltage • Alarm alerts via the status relay Alarm Power supply, 0 V 51 44 NC Power supply, +24 V 52 Power supply, +24 V 43 Status relay, N.C. Backup, +24 V 53 42 Status relay, shared Backup, 0 V 54 41 Status relay, N.O. NC 0V NC +24 V 81 NC 82 Status 0V 83 +24 V NC 84 NC 85 Power supply, 0 V Technical data Input Power supply Max. input current Backup power supply Trigger level for the power supply Output, power supply Output voltage Output power Output current Output, status relay in safe zone Max. voltage Max. current Max. AC power General data Efficiency degree Ambient temperature Storage temperature Power consumption Protection degree Weight Humidity Approvals Dimensions Clamping range (nominal / min. / max.) Length x width x height 21.6...26.4 V DC 4A 21.6...26.4 V DC Fault < 21 V DC 16.8...31.2 V DC 2.5A Input voltage -0.5 V DC @ 4 A max. 96 W max. 4 A = U input = P input = I input 250 AC / 30 V DC 2 A AC / 2 A DC 500 VA / 60 W mm mm2 > 97.9 % -20...+60 °C -20...+85 °C <2W IP20 140 g < 95 %, no condensation cULus, cFMus, ATEX, IECEx Zone 2, DNV, GOST Screw connection 2.5 / 0.5 / 2.5 119.2 / 22.5 / 113.6 100 % -25...+70 °C -40...+85 °C <2W IP20 70 g < 95 %, no condensation cULus, ATEX, IECEx Zone 2, GL, DNV, cFMus, GOST Screw connection 2.5 / 0.5 / 2.5 114.3 / 6.1 / 112.5 Type ACT20-Feed-In-PRO-S Type ACT20-FEED-IN-BASIC-S Note Ordering data Qty. 1 Part No. 8965500000 Qty. 1 Part No. 12824900000 Note 16 Subject to technical changes • 03/14 • 2.15M • LIT1126