MANN SERIES MANN SERIES – Signal transmitter ITXPlus Universal loop-powered (two-wire) signal isolator/converter Application 1: The ITXPlus is a compact, loop-powered, electrically-isolated, programmable signal isolator/converter. On the input side, optionally DC-current/voltage signals, 2-, 3-, or 4-wire PT100s, and thermocouples can be connected. The ITXPlus measures, filters and isolates the input parameters. It converts them into a proportional 4...20 mA signal. 4 ... 20 mA Power supply 4 ... 20 mA / 24 V DC ITXPlus PLC Application 2: 4 ... 20 mA / 24 V DC Thermocouple ITXPlus PLC D For linear temperature measurements, all standard types of thermocouples and resistance temperature detectors (RTDs) can be connected. The ITXPlus can also process signals from any non-linear resistance device, such as an NTC, PTC, or log. potentiometer. For this, the appropriate characteristic may be programmed into a table containing up to 101 measurement values. Application 3: 4 ... 20 mA / 24 V DC RTD ITXPlus PLC Application 4: 4 ... 20 mA / 24 V DC If the sensor is replaced or changed on the input side, then a fully-automatic calibration may be performed. The internal program also features many square-root, linear and x3/2-/x5/2-transfer functions. Other characterics which have not been pre-programmed can be entered directly using a PC. In this way, any sensor may be reproduced. The configuration software is user-friendly and runs on any PC after installation. It also allows the ITXPlus to be configured during active operations. The CBX100 interface connects the ITXPlus with the PC. It implements complete electrical isolation between the serial port and the signal transmitter. D.14 Potentiometer ITXPlus PLC The ITXPlus signal converter, which is rail mounted, and the CBX100 interface have the following technical characteristics: • A universal input for DC signals/thermocouples and RTD sensors • Complete electrical isolation • Loop-powered output • Programmable via PC • Automatic cold-junction compensation for thermocouple inputs • Automatic wire-length compensation for resistance temperature detector (RTD) inputs • Sensor wire-break detection • Pre-set and user-defined linearisation • Compact design - 12.5 mm width • Mounts on TS35 rail ITXPlus Series ITXPlus Universal signal isolator / amplifier in 2-wire design Programmable with T-Set MANN SERIES MANN SERIES - Signal transmitter • Output loop-powered • Programmable with PC • Pluggable connection terminals • Compact housing • Current or voltage input • Thermocouple +24 V + • Temperature resistance L + + 1 3 4 Iout I 5 W Connections Technical data Input Type ersal Signaltrenner/-verstärker, Thermokoppler, RTD Type, thermocouple / L / N / R / S / T / W3 / W5 - 200…+ 2300 °C je nach Thermoelement Input current Input voltage 100…+200 mV) Input resistance ingang) oder 40 Ω (Stromeingang) Input Universal signal isolator / amplifier, thermocoupler, RTD B / C / E / J / K / L / N / R / S / T / W3 / W5 -200…+ 2300 °C depending on thermocoupler -10…+20 mA (min. span 1 mA) t -5...+10 V / -100...+200 mV (min. span 0.5 V / 4 mV) 2 MΩ (Voltage input) or 40 Ω (current input) Output Current output 4…20 mA rrent + 22 mA of range < 20 mVss [(Vs - 10) / 0.02] Ω (Typically 700 Ω @ 24 V DC) PC and CBX100 Interface required 7940010208 General data 10…40 V DC, powered by loop current 0.005 % / V n the voltage supply 10…90 % (no condensation) typ. 0,02 % / °C ficient 0.1 % / 10,000 h 20…200 ms 1…100 filter factor < ± 0,5 % iation Typically 200 ms (10 to 90 %) 4 kV (1.2/50 μs) 2 kV between ports 300 Veff direct or reverse -10 °C…+70 °C / -20 °C…+70 °C DIN EN 61326 s Output Type ent output Output current Limits of range Residual ripple ss Load resistancemega; (Typically 700 Ω @ 24 V DC) Calibration / set-up ace required 7940010208 General data Voltage supply DC, powered by loop current Influence on the voltage supply Humidity % (no condensation) Temperature coefficient Long-term drift h Cycle time s Digital filter factor Interference radiation Step response time for signal jump of 10 to 90 %) Impulse withstand voltage ) Isolation voltage b> for 60 sec. Rated voltage Transmit function d Operating temperature/Storage temperature EMC standards Approvals Data of Housing Clamping range (rating- / min. / max.) Type of connection / Terminal rail Type of Housing / Weight Length x width x height 6 2 • Conversion, isolation and filtering of all standard types of signals and sensors H J/V/I Terminal Signal 5 Loop –ve 6 Loop +ve 1 Signal + Power supply Sensor Signal + Power supply Storage (only for programming) A-Sense A B B-Sense A-Sense A B A B Signal + Signal – Signal + Signal – A Wiper B 2 1 3 2 4 1 3 2 3 2 1 2 1 2 3 1 2 Supply voltage Thermocouple 4-wire PT100/RTD (or resistance) 3-wire PT100/RTD (or resistance) 2-wire PT100/RTD (or resistance) Voltage (mV or V) Current (mA) Potentiometer CE, cULus provals mm2 mm 1.5 / 0.5 / 2.5 Screw connection / TS 35 Plastic housing / 83 g 92.4 x 12.5 x 112.4 Note Ordering data Type Universal input Special adjustment Note Type ITX+ 4-20mA/4-20mA ITX+ variable Qty. 1 1 Order No. 7940016563 8944980000 Additional input and output versions available on request Accessories Note CBX100 Interface - 7940010208 Connects the ITX+ with the PC for calibration D.15 D MANN SERIES – Signal transmitter MANN SERIES ITXPlus Series ITXPlus Universal signal isolator / amplifier in 2-wire design • Output loop-powered • Programmable with PC • Pluggable connection terminals • Compact housing • Current or voltage input • Thermocouple • Temperature resistance L • Conversion, isolation and filtering of all standard types of signals and sensors D H W Technical data Thermocouple inputs Inputs Typ Typ Standard B C E IEC584 J K L DIN 43710 N R IEC584 S T W3 ASTM E98890 W5 User-defined Input Cold-junction compensation Wire-break recognition mA volt 2, 3, 4-wire RTD mV Type Standard PT 100 DIN 43710 PT 100 JIS PT 200 DIN 43710 PT 200 JIS NI 120 DIN 43710 CU 100 DIN 43710 Cable resistance Sensor current Influence of cable resistance sensor (3/4 wire) Resistance Accuracy 2–101 values ± 1.0 °C yes – 10 mA to + 20 mA to 40 Ω input resistance (min. range 1 mA) – 5 V to + 10 V to 2 M Ω input resistance (min. range 0.5 V) – 100 mV to + 200 mV to 2 M Ω input resistance (min range 4 mV) Lower limit Upper limit –200 °C 850 °C –200 °C 630 °C –200 °C 850 °C –200 °C 630 °C –80 °C 320 °C –100 °C 260 °C 5 Ω max. 0.1 mA < 0.002 Ω per Ω wire resistance Min. range 50 °C 100 °C 0 to 10 k Ω (min. range 10 Ω) Type E,J,K,L,N,T,U Range < 500 °C > 500 °C B, C, R, S, W3, W5 mV, V, mA PT100/RTD Resistance D.16 Thermocouple, PT100/RTD, mA, volt, mV, resistance Lower limit Upper limit Min. range 400 °C 1828 °C 200 °C 0 °C 2000 °C –100 °C 1000 °C 50 °C –100 °C 1200 °C –180 °C 1372 °C –100 °C 900 °C –180 °C 1300 °C 100 °C –50 °C 1760 °C 200 °C –50 °C 1760 °C –200 °C 400 °C 50 °C 0 °C 2300 °C 200 °C All Temperature coefficient ± 0.02 °C per C° ambient temperature ± 0.01?% of end value per °C ambient temperature ± 0.02 °C per C° ambient temperature Accuracy ≤ ± 1.0 °C ≤ ≤ ≤ ≤ ± ± ± ± 2.0 0.1 0.5 0.1 °C % of end value °C % of end value MANN SERIES – Signal transmitter MANN SERIES CBX100 USB • Interface for ITXPlus configuration • USB port for PC • Tx and Rx status displays D Technical data Connections Display Status indicator Eingang LED (send / receive) Eingang General data Isolation voltage Operating temperature / storage temerature Air humidity Software Interface Approvals 500 V for 60s –20 °C...+70 °C / –25 °C...+70 °C 10…90 % (no condensation) T-Set as of V.4.2 (can be downloaded from www.mannseries.com) USB CE, cULus ITXPlus 1 2 3 4 Output Input PC CBX100 Note: Disconnect the charging unit before operating the CBX100 Note: Ordering data Type Interface device Type CBX100 USB Qty. 1 Order No. 7940025031 Note: Accessories Note: D.17