SITRANS RD100 Catalog Sheet

© Siemens AG 2016
Supplementary Components
Displays
SITRANS RD100
■ Overview
Power supply
External loop power supply
30 V DC max.
Display
• 1.0 inch (2.54 cm) high LCD
• Numeric range from
-1 000 … +1 999
Certificates and approvals
Non-hazardous
Hazardous
• Intrinsically Safe
• Non-incendive
CE
• CSA/FM Class I, II, III, Div. 1,
Groups A, B, C, D, E, F, G T4
• CSA/FM Class I, Zone 0, Group IIC
• CSA/FM Class I, Div. 2, Groups A,
B, C, D
• CSA/FM Class II and III, Div. 2,
Groups F and G
Options
The SITRANS RD100 is a 2-wire loop powered, NEMA 4X
enclosed remote digital display for process instrumentation.
Mounting
• 2 inch (5.08 cm) pipe mounting kit
(zinc plated or stainless steel)
• Panel mounting kit
■ Benefits
•
•
•
•
•
Easy setup
Approved for hazardous locations
NEMA 4X, IP67 impact-resistant enclosure
Simple two-step calibration
Two modes of input allow for easy servicing, with no
interruption of loop required
■ Application
7
The RD100 is very versatile. It can be installed indoors or
outdoors, in hot or cold environments, and in safe or hazardous
areas.
It has been approved by FM and CSA as Intrinsically Safe and
non-incendive, and operates from -40 to +85 ºC
(-40 to +185 ºF), adding only 1 V to the loop.
Calibration consists of a quick two-step process involving the
adjustment of only two non-interacting potentiometers.
• Key Applications: remotely displays process variables in level,
flow, pressure, temperature, and weighing applications, in a
4 to 20 mA loop.
■ Technical specifications
Mode of operation
Measuring principle
Analog to digital conversion
Measuring range
4 … 20 mA
Measuring points
1 instrument only
Accuracy
± 0.1 % of span ± 1 count
Rated operating conditions
Ambient conditions
• Operating temperature range
-40 … +85 ºC (-40 … +185 ºF)
Design
Weight
340 g (12 oz)
Material (enclosure)
Impact-resistant glass filled polycarbonate body and clear polycarbonate
cover
Degree of protection
NEMA 4X, IP67
7/10
Siemens FI 01 · Update 06/2016
Selection and Ordering data
Article No.
SITRANS RD100
A 2-wire loop powered, NEMA 4X enclosed remote
digital display for process instrumentation.
7ML574177A A 0 0 - 0
Click on the Article No. for the online configuration in the PIA Life Cycle Portal.
Conduit hole location (½ inch)
None
Bottom
Rear
Top
Approvals
FM/CSA
CE
}
}


1
2
3
4
A
B
} Available ex stock. For details see page 9/5 in the appendix.
 We can offer shorter delivery times for configurations designated with the
Quick Ship Symbol . For details see page 9/5 in the appendix.
Selection and Ordering data
Operating Instructions
English
German
Note: The Operating Instructions should be ordered
as a separate line item.
All literature is available to download for free, in a
range of languages, at http://www.siemens.com/
processinstrumentation/documentation
This device is shipped with the Siemens Level and
Weighing manual DVD containing Quick Starts and
Operating Instructions.
Accessories
Panel mount kit
2 inch (5.08 cm) pipe mounting kit (zinc plated seal)
2 inch (5.08 cm) pipe mounting kit (stainless steel,
Type 304, EN 1.4301)
Article No.
7ML1998-5JU01
7ML1998-5JU31
7ML1930-1BN
7ML1930-1BP
7ML1930-1BQ
© Siemens AG 2016
Supplementary Components
Displays
SITRANS RD100
■ Dimensional drawings
RD100 - front view
RD100 - side view
Wall mounting
holes beneath
cover screws
E
F
A
C
D
B
A: 80 (3.15)
C: 60 (2.36)
E: 65 (2.56)
B: 140 (5.51)
D: 120 (4.72)
F: 20 (0.79)
SITRANS RD100, dimensions in mm (inch)
■ Schematics
Control loop connected to
input signal PCB
Calibrator connected to
input signal PCB
Input signal
PCB
Display PCB component side
(may be removed for bench calibration)
LO calibration control
HI calibration control
Balance control
(factory adjust only)
S-
Calibrator connected to
display PCB
Display PCB
component side
S+ S- S- S+
DP1
DP2
DP3
Loop jumper
(remove when display PCB
is connected)
S+
Black
-
Red
4...20 mA
S+ S-
S- S+
+
+
Power
supply
DP1
DP2
DP3
Field wiring is
made to the
Input Signal
PCB which is
mounted to the
base of the
enclosure.
S+
Calibrated current
source
The display PCB may be removed from
the enclosure for bench calibration. Loop
jumper must be installed on input signal
PCB to maintain loop.
Refer to RD100 instruction manual for
more details.
Transmitter
Loop jumper
+
-
Calibrated current
source
7
S-
Input signal PCB
(mounted to base
of enclosure)
CE version
Figure 2: Control loop connected
to main board with backlight
Figure 1: Calibrator connected
to main board with no backlight
Main board back side
Main board back side
Main board front side
Field wiring is
made to the back
side of the main
board which is
mounted in
the enclosure.
-
S+ Signal Positive Connection
S- Signal Negative Connection
B- Signal Negative Connection
if Using Backlight
+
Calibrated
current source
+
Calibrated
current source
J2 - Decimal Point Location
Selection
R4 - HI Calibration Coarse Control
R5 - HI Calibration Fine Control
R6 - LO Calibration Coarse Control
R7 - LO Calibration Fine Control
Power
supply +
4 ... 20 mA
+
-
Transmitter
Non-hazardous
area
S+ Signal positive connection
S- Signal negative connection
B- Signal negative connection
if Using Backlight
Hazardous area
SITRANS RD100 connections
Siemens FI 01 · Update 06/2016