Si5482DU Vishay Siliconix N-Channel 30-V (D-S) MOSFET FEATURES PRODUCT SUMMARY VDS (V) ID (A)a RDS(on) (Ω) 30 0.015 at VGS = 10 V 12 0.0175 at VGS = 4.5 V 12 Qg (Typ.) 16 nC PowerPAK ChipFET Single 1 D AE XXX 4 Lot Traceability and Date Code D D • Load Switch, PA Switch, and Battery Switch for Portable Applications D Part # Code S 6 COMPLIANT G D 7 Marking Code 3 D RoHS APPLICATIONS 2 D 8 • Halogen-free • TrenchFET® Power MOSFET • New Thermally Enhanced PowerPAK® ChipFET® Package - Small Footprint Area - Low On-Resistance - Thin 0.8 mm Profile G S 5 Bottom View S N-Channel MOSFET Ordering Information: Si5482DU-T1-GE3 (Lead (Pb)-free and Halogen-free) ABSOLUTE MAXIMUM RATINGS TA = 25 °C, unless otherwise noted Parameter Symbol Limit Drain-Source Voltage VDS 30 Gate-Source Voltage VGS ± 12 TC = 25 °C Continuous Drain Current (TJ = 150 °C) TC = 70 °C TA = 25 °C Continuous Source-Drain Diode Current 12a ID 11.1b, c 8.8b, c 40 IDM TC = 25 °C TA = 25 °C TC = 70 °C TA = 25 °C 2.6b, c 31 20 PD W 3.1b, c TA = 70 °C 2b, c - 55 to 150 TJ, Tstg Operating Junction and Storage Temperature Range A 12a IS TC = 25 °C Maximum Power Dissipation V 12a TA = 70 °C Pulsed Drain Current Unit Soldering Recommendations (Peak Temperature)d, e °C 260 THERMAL RESISTANCE RATINGS Parameter Maximum Junction-to-Ambientb, f Maximum Junction-to-Case (Drain) Symbol Typical Maximum t≤5s RthJA 34 40 Steady State RthJC 3 4 Unit °C/W Notes: a. Package limited. b. Surface Mounted on 1" x 1" FR4 board. c. t = 5 s. d. See Solder Profile (http://www.vishay.com/ppg?73257). The PowerPAK ChipFET is a leadless package. The end of the lead terminal is exposed copper (not plated) as a result of the singulation process in manufacturing. A solder fillet at the exposed copper tip cannot be guaranteed and is not required to ensure adequate bottom side solder interconnection. e. Rework Conditions: manual soldering with a soldering iron is not recommended for leadless components. f. Maximum under Steady State conditions is 90 °C/W. Document Number: 73594 S-81448-Rev. B, 23-Jun-08 www.vishay.com 1 Si5482DU Vishay Siliconix SPECIFICATIONS TJ = 25 °C, unless otherwise noted Parameter Symbol Test Conditions Min. VDS VGS = 0 V, ID = 1 mA 30 Typ. Max. Unit Static Drain-Source Breakdown Voltage VDS Temperature Coefficient ΔVDS/TJ VGS(th) Temperature Coefficient ΔVGS(th)/TJ Gate-Source Threshold Voltage ID = 250 µA VGS(th) VDS = VGS, ID = 250 µA Gate-Source Leakage IGSS VDS = 0 V, VGS = ± 12 V Zero Gate Voltage Drain Current IDSS On-State Drain Currenta ID(on) Drain-Source On-State Resistancea Forward Transconductancea RDS(on) gfs V 24.5 mV/°C - 4.3 0.6 2 V ± 100 ns VDS = 30 V, VGS = 0 V 1 VDS = 30 V, VGS = 0 V, TJ = 55 °C 10 VDS ≥ 5 V, VGS = 10 V 30 µA A VGS = 10 V, ID = 7.4 A 0.0125 0.015 VGS = 4.5 V, ID = 6.8 A 0.0145 0.0175 VDS = 15 V, ID = 7.4 A 35 Ω S b Dynamic Input Capacitance Ciss Output Capacitance Coss Reverse Transfer Capacitance Crss Total Gate Charge Qg Gate-Source Charge Qgs Gate-Drain Charge Qgd Gate Resistance Turn-On Delay Time Rise Time Turn-Off Delay Time Fall Time Turn-On Delay Time Rise Time Turn-Off Delay Time Fall Time Rg 1610 VDS = 15 V, VGS = 0 V, f = 1 MHz VDS = 15 V, VGS = 10 V, ID = 11.1 A VDS = 15 V, VGS = 4.5 V, ID = 11.1 A td(off) 34 51 16 24 3.6 f = 1 MHz VDD = 15 V, RL = 1.7 Ω ID ≅ 8.8 A, VGEN = 4.5 V, Rg = 1 Ω Ω 5.1 10 15 85 130 30 45 tf 10 15 td(on) 5 10 10 15 35 55 10 15 tr td(off) nC 3.7 td(on) tr pF 210 120 VDD = 15 V, RL = 1.7 Ω ID ≅ 8.8 A, VGEN = 10 V, Rg = 1 Ω tf ns Drain-Source Body Diode Characteristics Continuous Source-Drain Diode Current IS Pulse Diode Forward Current ISM Body Diode Voltage VSD Body Diode Reverse Recovery Time trr Body Diode Reverse Recovery Charge Qrr Reverse Recovery Fall Time ta Reverse Recovery Rise Time tb TC = 25 °C 12 40 IS = 8.8 A, VGS = 0 V IF = 8.8 A, dI/dt = 100 A/µs, TJ = 25 °C A 0.8 1.2 V 25 50 ns 18 27 nC 14.5 10.5 ns Notes: a. Pulse test; pulse width ≤ 300 µs, duty cycle ≤ 2 %. b. Guaranteed by design, not subject to production testing. Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to absolute maximum rating conditions for extended periods may affect device reliability. www.vishay.com 2 Document Number: 73594 S-81448-Rev. B, 23-Jun-08 Si5482DU Vishay Siliconix TYPICAL CHARACTERISTICS 25 °C, unless otherwise noted 40 20 VGS = 10 thru 3 V 16 I D - Drain Current (A) I D - Drain Current (A) 32 24 16 12 8 TC = 125 °C VGS = 2 V 8 4 0 0.0 0.5 1.0 1.5 2.0 2.5 TC = 25 °C TC = - 55 °C 0 0.0 3.0 0.5 VDS - Drain-to-Source Voltage (V) 1.5 2.0 2.5 VGS - Gate-to-Source Voltage (V) Output Characteristics Transfer Characteristics 2500 0.018 2000 0.016 C - Capacitance (pF) R DS(on) - On-Resistance (mΩ) 1.0 VGS = 4.5 V 0.014 VGS = 10 V Ciss 1500 1000 0.012 500 Coss Crss 0 0.010 0 8 16 24 32 0 40 5 10 15 20 25 ID - Drain Current (A) VDS - Drain-to-Source Voltage (V) On-Resistance vs. Drain Current and Gate Voltage Capacitance 10 30 1.8 1.6 8 R DS(on) - On-Resistance (Normalized) VGS - Gate-to-Source Voltage (V) ID = 11.1 A VDS = 15 V 6 4 VDS = 24 V 2 1.4 1.2 1.0 0.8 0 0 5 10 15 20 25 Qg - Total Gate Charge (nC) Gate Charge Document Number: 73594 S-81448-Rev. B, 23-Jun-08 30 35 0.6 - 50 - 25 0 25 50 75 100 125 150 TJ - Junction Temperature (°C) On-Resistance vs. Junction Temperature www.vishay.com 3 Si5482DU Vishay Siliconix TYPICAL CHARACTERISTICS 25 °C, unless otherwise noted 40 RDS(on) - Drain-to-Source On-Resistance (Ω) 0.040 I S - Source Current (A) TJ = 150 °C 10 TJ = 25 °C 1 0.0 0.030 0.025 TA = 125 °C 0.020 0.015 TA = 25 °C 0.010 0.2 0.4 0.6 0.8 1.0 0 1.2 4 6 8 10 VSD - Source-to-Drain Voltage (V) VGS - Gate-to-Source Voltage (V) On-Resistance vs. Gate-to-Source Voltage 50 1.2 40 ID = 250 µA 1.0 Power (W) VGS(th) (V) 2 Source-Drain Diode Forward Voltage 1.4 0.8 30 20 0.6 0.4 - 50 ID = 7.4 A 0.035 10 - 25 0 25 50 75 100 125 0 150 0.001 0.01 0.1 TJ - Temperature (°C) 1 10 100 1000 Time (s) Threshold Voltage Single Pulse Power, Junction-to-Ambient 100 Limited by RDS(on)* BVDSS Limited 100 µs I D - Drain Current (A) 10 1 ms 1 10 ms 100 ms 0.1 1s TA = 25 °C Single Pulse 10 s DC 0.01 0.1 1 10 100 VDS - Drain-to-Source Voltage (V) * VGS > minimum VGS at which R DS(on) is specified Safe Operating Area, Junction-to-Ambient www.vishay.com 4 Document Number: 73594 S-81448-Rev. B, 23-Jun-08 Si5482DU Vishay Siliconix TYPICAL CHARACTERISTICS 25 °C, unless otherwise noted 35 40 30 Power Dissipation (W) I D - Drain Current (A) 32 24 16 Package Limited 8 25 20 15 10 5 0 0 0 25 50 75 100 125 150 25 50 75 100 125 TC - Case Temperature (°C) TC - Case Temperature (°C) Current Derating* Power Derating 150 * The power dissipation PD is based on TJ(max) = 150 °C, using junction-to-case thermal resistance, and is more useful in settling the upper dissipation limit for cases where additional heatsinking is used. It is used to determine the current rating, when this rating falls below the package limit. Document Number: 73594 S-81448-Rev. B, 23-Jun-08 www.vishay.com 5 Si5482DU Vishay Siliconix TYPICAL CHARACTERISTICS 25 °C, unless otherwise noted 1 Normalized Effective Transient Thermal Impedance Duty Cycle = 0.5 0.2 Notes: 0.1 0.1 PDM 0.05 t1 t2 1. Duty Cycle, D = t1 t2 2. Per Unit Base = RthJA = 75 °C/W 0.02 3. TJM - TA = PDMZthJA(t) Single Pulse 4. Surface Mounted 0.01 10-4 10-3 10-2 10-1 1 Square Wave Pulse Duration (s) 10 100 1000 Normalized Thermal Transient Impedance, Junction-to-Ambient 1 Normalized Effective Transient Thermal Impedance Duty Cycle = 0.5 0.2 0.1 0.05 0.02 0.1 10-4 Single Pulse 10-3 10-2 Square Wave Pulse Duration (s) 10-1 1 Normalized Thermal Transient Impedance, Junction-to-Case Vishay Siliconix maintains worldwide manufacturing capability. Products may be manufactured at one of several qualified locations. Reliability data for Silicon Technology and Package Reliability represent a composite of all qualified locations. For related documents such as package/tape drawings, part marking, and reliability data, see http://www.vishay.com/ppg?73594. www.vishay.com 6 Document Number: 73594 S-81448-Rev. B, 23-Jun-08 Legal Disclaimer Notice www.vishay.com Vishay Disclaimer ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE. Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively, “Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other disclosure relating to any product. Vishay makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or the continuing production of any product. To the maximum extent permitted by applicable law, Vishay disclaims (i) any and all liability arising out of the application or use of any product, (ii) any and all liability, including without limitation special, consequential or incidental damages, and (iii) any and all implied warranties, including warranties of fitness for particular purpose, non-infringement and merchantability. Statements regarding the suitability of products for certain types of applications are based on Vishay’s knowledge of typical requirements that are often placed on Vishay products in generic applications. Such statements are not binding statements about the suitability of products for a particular application. It is the customer’s responsibility to validate that a particular product with the properties described in the product specification is suitable for use in a particular application. Parameters provided in datasheets and/or specifications may vary in different applications and performance may vary over time. All operating parameters, including typical parameters, must be validated for each customer application by the customer’s technical experts. Product specifications do not expand or otherwise modify Vishay’s terms and conditions of purchase, including but not limited to the warranty expressed therein. Except as expressly indicated in writing, Vishay products are not designed for use in medical, life-saving, or life-sustaining applications or for any other application in which the failure of the Vishay product could result in personal injury or death. Customers using or selling Vishay products not expressly indicated for use in such applications do so at their own risk. Please contact authorized Vishay personnel to obtain written terms and conditions regarding products designed for such applications. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document or by any conduct of Vishay. Product names and markings noted herein may be trademarks of their respective owners. Material Category Policy Vishay Intertechnology, Inc. hereby certifies that all its products that are identified as RoHS-Compliant fulfill the definitions and restrictions defined under Directive 2011/65/EU of The European Parliament and of the Council of June 8, 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment (EEE) - recast, unless otherwise specified as non-compliant. Please note that some Vishay documentation may still make reference to RoHS Directive 2002/95/EC. We confirm that all the products identified as being compliant to Directive 2002/95/EC conform to Directive 2011/65/EU. Vishay Intertechnology, Inc. hereby certifies that all its products that are identified as Halogen-Free follow Halogen-Free requirements as per JEDEC JS709A standards. Please note that some Vishay documentation may still make reference to the IEC 61249-2-21 definition. We confirm that all the products identified as being compliant to IEC 61249-2-21 conform to JEDEC JS709A standards. Revision: 02-Oct-12 1 Document Number: 91000