SUF501 5C

SUF501_5C
VOLTAGE 50V ~ 600V
5.0AMP Surface Mount Super Fast Recovery Rectifiers
Features
• Ideal for surface mount applications
• Easy pick and place
• Built-in strain relief
• Super Fast switching speed under 35ns
• RoHS compliant package
Mechanical Data
• Case: Molded plastic
• Epoxy: UL 94V-0 rate flame retardant
• Metallurgically bonded construction
• Polarity: Color band denotes cathode end
• Mounting position: Any
• Weight: 0.229 grams
Packing &Order Information
3,000/Reel
Graphic symbol
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Rating 25 C ambient temperature unless otherwise specified. Single phase half wave, 60Hz, resistive
or inductive load. For capacitive load, derate current by 20%.
TYPE NUMBER
SUF501C SUF502C SUF503C SUF504C SUF505C
Unit
Maximum Repetitive Peak Reverse Voltage
50
100
200
400
600
V
Working RMS Voltage
35
70
140
280
420
V
Maximum DC Blocking Voltage
50
100
200
400
600
V
Maximum Average Forward Rectified Current
.375"(9.5mm) Lead Length at Ta=55°C
5.0
A
120
A
Peak Forward Surge Current, 8.3 ms single
half sine-wave superimposed on rated load
(JEDEC method)
Maximum Instantaneous Forward Voltage at
5.0A
0.98
1.25
1.7
V
Maximum DC Reverse Current Ta=25 C
5.0
μA
at Rated DC Blocking Voltage Ta=100 C
80
μA
Maximum Reverse Recovery Time (Note 1)
35
nS
Publication Order Number: [SUF501_5C]
© Bruckewell Technology Corporation Rev. A -2014
SUF501_5C
VOLTAGE 50V ~ 600V
5.0AMP Surface Mount Super Fast Recovery Rectifiers
Rating 25 C ambient temperature unless otherwise specified. Single phase half wave, 60Hz, resistive
or inductive load. For capacitive load, derate current by 20%.
TYPE NUMBER
SUF501C SUF502C SUF503C SUF504C SUF505C
Typical Junction Capacitance (Note 2)
Operating and Storage Temperature Range
TJ, TSTG
Unit
50
pF
-65~ +175
°C
NOTES:
1. Reverse Recovery Time test condition: IF=0.5A, IR=1.0A, IRR=0.25A
2. Measured at 1MHz and applied reverse voltage of 4.0V D.C.
Publication Order Number: [SUF501_5C]
© Bruckewell Technology Corporation Rev. A -2014
SUF501_5C
VOLTAGE 50V ~ 600V
5.0AMP Surface Mount Super Fast Recovery Rectifiers
■RATING AND CHARACTERISTIC CURVES (SUF501C THRU SUF505C)
FIG.1-TYPICAL FORWARD
CHARACTERISTICS
FIG.2-TYPICAL FORWARD CURRENT
DERATING CURVE
FIG.3- TEST CIRCUIT DIAGRAM AND REVERSE
FIG.4-MAXIMUM NON-REPETITIVE FORWARD SURGE
RECOVERY TIME CHARACTERISTICS
CURRENT
FIG.5-TYPICAL JUNCTION CAPACITANCE
Publication Order Number: [SUF501_5C]
© Bruckewell Technology Corporation Rev. A -2014
SUF501_5C
VOLTAGE 50V ~ 600V
5.0AMP Surface Mount Super Fast Recovery Rectifiers
Disclaimer
ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE
WITHOUT NOTICE TO IMPROVE RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE.
Bruckewell Technology Inc., its affiliates, agents, and employees, and all persons acting on its or
their behalf (collectively, “Bruckewell”), disclaim any and all liability for any errors, inaccuracies or
incompleteness contained in any datasheet or in any other disclosure relating to any product.
Bruckewell makes no warranty, representation or guarantee regarding the suitability of the products
for any particular purpose or the continuing production of any product. To the maximum extent
permitted by applicable law, Bruckewell disclaims
(i) Any and all liability arising out of the application or use of any product.
(ii) Any and all liability, including without limitation special, consequential or incidental damages.
(iii) Any and all implied warranties, including warranties of fitness for particular purpose,
non-infringement and merchantability.
Statements regarding the suitability of products for certain types of applications are based on
Bruckewell’s knowledge of typical requirements that are often placed on Bruckewell products in
generic applications.
Such statements are not binding statements about the suitability of products for a particular
application. It is the customer’s responsibility to validate that a particular product with the properties
described in the product specification is suitable for use in a particular application. Parameters
provided in datasheets and/or specifications may vary in different applications and performance
may vary over time.
Product specifications do not expand or otherwise modify Bruckewell’s terms and conditions of
purchase, including but not limited to the warranty expressed therein.
Publication Order Number: [SUF501_5C]
© Bruckewell Technology Corporation Rev. A -2014