ESDA6V1W6

ESDA6V1W6
Transil array for data protection
Description
The ESDA6V1W6 is monolithic suppressor designed to
protect components connected to data and transmission
lines against ESD. This device clamps the voltage just
above the logic level supply for positive transients and to
a diode drop below ground for negative transients.
Features
• 5 Unidirectional Transil functions
• Low leakage current: < 1 μA
• High integration
• RoHS Compliant Package
Application
• Computers
• Printers
• Communication systems
• Cellular phones handsets and accessories
• Wireline and wireless telephone sets
• Set top boxes
Complies with the following standards
•IEC61000-4-2
•Level 4 15 kV (air discharge)
8 kV(contact discharge)
•MIL STD 883E - Method 3015-7 Class 3
•25 kV HBM (Human Body Model)
Packing &Order Information
3,000/Reel
Graphic symbol
Publication Order Number: [ESDA6V1W6]
© Bruckewell Technology Corporation Rev. A -2016
ESDA6V1W6
Transil array for data protection
Absolute Ratings (Tamb=25°C )
Symbol
Parameter
Value
Unit
Ppp
Peak Pulse Power (tp = 8/20μs)
150
W
TJ
Maximum lead temperature for soldering during 10s
260
°C
TSTG
Storage Temperature Range
-40 to +125
°C
TOP
Operating Temperature Range
-40 to +125
°C
Electrical Characteristics
Part Numbers
ESDA6V1W5
Min.
V
VBR
Typ.
V
6.1
6.7
IF
C
μA
VF
Max.
V
mA
Typ. 0v bias
1
1.25
200
35
Max.
V
IT
VRWM
IR
mA
V
7.2
1
5
1.Square pulse IPP=15A,tp=2.5μs 2.V=aT*(T-25°C)*V(25°C)
Publication Order Number: [ESDA6V1W6]
© Bruckewell Technology Corporation Rev. A -2016
ESDA6V1W6
Transil array for data protection
■Typical
Device Characteristics
FIG.1-PEAK PULSE POWER VERSUS
EXPONENTIAL PULSE DURATION (TJ
INITIAL=25°C)
FIG.2-CLAMPING VOLTAGE VERSUS PEAK
PULSE CURRENT (TJ INTIAL=25°C,
RECTANGULAR WAVEFORM, TP=2.5μs)
FIG.3-CAPACITANCE VERSUS REVERSE APPLIED
VOLATGE
FIG.4-PEAK FORWARD VOLTAGE DROP VERSUS
FORWARD CURRENT
Publication Order Number: [ESDA6V1W6]
© Bruckewell Technology Corporation Rev. A -2016
ESDA6V1W6
Transil array for data protection
Disclaimer
ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE
WITHOUT NOTICE TO IMPROVE RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE.
Bruckewell Technology Inc., its affiliates, agents, and employees, and all persons acting on its or
their behalf (collectively, “Bruckewell”), disclaim any and all liability for any errors, inaccuracies or
incompleteness contained in any datasheet or in any other disclosure relating to any product.
Bruckewell makes no warranty, representation or guarantee regarding the suitability of the products
for any particular purpose or the continuing production of any product. To the maximum extent
permitted by applicable law, Bruckewell disclaims
(i) Any and all liability arising out of the application or use of any product.
(ii) Any and all liability, including without limitation special, consequential or incidental damages.
(iii) Any and all implied warranties, including warranties of fitness for particular purpose,
non-infringement and merchantability.
Statements regarding the suitability of products for certain types of applications are based on
Bruckewell’s knowledge of typical requirements that are often placed on Bruckewell products in
generic applications.
Such statements are not binding statements about the suitability of products for a particular
application. It is the customer’s responsibility to validate that a particular product with the properties
described in the product specification is suitable for use in a particular application. Parameters
provided in datasheets and/or specifications may vary in different applications and performance
may vary over time.
Product specifications do not expand or otherwise modify Bruckewell’s terms and conditions of
purchase, including but not limited to the warranty expressed therein.
Publication Order Number: [ESDA6V1W6]
© Bruckewell Technology Corporation Rev. A -2016