IRF HFA08TB120SPBF

PD-96034
HFA08TB120SPbF
HEXFRED
Ultrafast, Soft Recovery Diode
TM
•
•
•
•
•
•
Features
Ultrafast Recovery
Ultrasoft Recovery
Very Low IRRM
Very Low Qrr
Specified at Operating Conditions
Lead-Free
VR = 1200V
VF(typ.)* = 2.4V
Base
Cathode
2
IF(AV) = 8.0A
Qrr (typ.)= 140nC
IRRM(typ.) = 4.5A
Benefits
• Reduced RFI and EMI
• Reduced Power Loss in Diode and Switching
Transistor
• Higher Frequency Operation
• Reduced Snubbing
• Reduced Parts Count
1
N/C
3
Anode
trr(typ.) = 28ns
di(rec)M/dt (typ.)* = 85A/µs
Description
International Rectifier's HFA08TB120S is a state of the art ultra fast recovery
diode. Employing the latest in epitaxial construction and advanced processing
techniques it features a superb combination of characteristics which result in
performance which is unsurpassed by any rectifier previously available. With
basic ratings of 1200 volts and 8 amps continuous current, the HFA08TB120S
is especially well suited for use as the companion diode for IGBTs and
MOSFETs. In addition to ultra fast recovery time, the HEXFRED product line
features extremely low values of peak recovery current (IRRM) and does not
exhibit any tendency to "snap-off" during the tb portion of recovery. The
HEXFRED features combine to offer designers a rectifier with lower noise and
significantly lower switching losses in both the diode and the switching transistor.
These HEXFRED advantages can help to significantly reduce snubbing,
component count and heatsink sizes. The HEXFRED HFA08TB120S is ideally
suited for applications in power supplies and power conversion systems (such
as inverters), motor drives, and many other similar applications where high
speed, high efficiency is needed.
D2 Pak
Absolute Maximum Ratings
Parameter
VR
IF @ TC = 100°C
IFSM
IFRM
PD @ TC = 25°C
PD @ TC = 100°C
TJ
TSTG
Cathode-to-Anode Voltage
Continuous Forward Current
Single Pulse Forward Current
Maximum Repetitive Forward Current
Maximum Power Dissipation
Maximum Power Dissipation
Operating Junction and
Storage Temperature Range
Max.
Units
1200
8.0
130
32
73.5
29
V
-55 to +150
A
W
°C
* 125°C
www.irf.com
1
10/07/05
HFA08TB120SPbF
Electrical Characteristics @ TJ = 25°C (unless otherwise specified)
Parameter
V BR
Cathode Anode Breakdown Voltage
V FM
Max Forward Voltage
IRM
Max Reverse Leakage Current
CT
Junction Capacitance
LS
Series Inductance
Min. Typ. Max. Units
1200 ––– –––
––– 2.6 3.3
––– 3.4 4.3
––– 2.4 3.1
––– 0.31 10
––– 135 1000
––– 11
20
–––
8.0
–––
V
V
µA
pF
nH
Test Conditions
IR = 100µA
IF = 8.0A
IF = 16A
IF = 8.0A, TJ = 125°C
VR = VR Rated
TJ = 125°C, V R = 0.8 x VR RatedD Rated
VR = 200V
Measured lead to lead 5mm from
package body
Dynamic Recovery Characteristics @ TJ = 25°C (unless otherwise specified)
Parameter
t rr
trr1
trr2
IRRM1
IRRM2
Qrr1
Qrr2
di(rec)M/dt1
di(rec)M/dt2
Reverse Recovery Time
See Fig. 5
Peak Recovery Current
See Fig. 6
Reverse Recovery Charge
See Fig. 7
Peak Rate of Fall of Recovery Current
See Fig. 8
During t b
Min. Typ. Max. Units
–––
–––
–––
–––
–––
–––
–––
–––
–––
28
63
106
4.5
6.2
140
335
133
85
–––
95
160
8.0
11
380
880
–––
–––
Test Conditions
IF = 1.0A, dif/dt = 200A/µs, VR = 30V
ns TJ = 25°C
TJ = 125°C
IF = 8.0A
TJ = 25°C
A
TJ = 125°C
VR = 200V
TJ = 25°C
nC
TJ = 125°C
dif/dt = 200A/µs
TJ = 25°C
A/µs
TJ = 125°C
Thermal - Mechanical Characteristics
Parameter
Tlead
RthJC
RthJA
Wt

‚
Lead Temperature
Thermal Resistance, Junction to Case
Thermal Resistance, Junction to Ambient
Weight
Min.
Typ.
Max.
––––
––––
––––
––––
––––
––––
––––
––––
2.0
0.07
300
1.7
40
––––
––––
Units
°C
K/W
g
(oz)
 0.063 in. from Case (1.6mm) for 10 sec
‚ Typical Socket Mount
2
www.irf.com
HFA08TB120SPbF
D2PAK Package Outline
Dimensions are shown in millimeters (inches)
D2PAK Part Marking Information
T HIS IS A HFA08T B120S
INT ERNATIONAL
RECTIFIER
LOGO
(K)
AS S EMBLY
LOT CODE
(N/C) (A)
www.irf.com
PART NUMBER
DAT E CODE
YY = YEAR
WW = WEEK
P = DES IGNATES LEAD-FREE
PRODUCT (OPTIONAL)
3
HFA08TB120SPbF
D2PAK Tape & Reel Information
Dimensions are shown in millimeters (inches)
Data and specifications subject to change without notice.
This product has been designed and qualified for the Consumer market.
Qualifications Standards can be found on IR’s Web site.
IR WORLD HEADQUARTERS: 233 Kansas St., El Segundo, California 90245, USA Tel: (310) 252-7105
TAC Fax: (310) 252-7903
Visit us at www.irf.com for sales contact information.10/05
4
www.irf.com