HPS-100 Factsheet

HPS-100
www.ams.com/Hydrogen-Sensors
HPS-100 – Hydrogen Process Sensor
-Fast and highly selective
-Low power and flexible packaging
-Tough and resistant
We provide innovative
analog solutions to
the most challenging
applications in sensor
and sensor interfaces,
power management,
and wireless.
General Description
The ams HPS-100 Hydrogen Process Sensor is an accurate, fast responding sensor designed for installation in harsh environments such as fuel cells, for example. The sensor will
measure hydrogen in the range of 0–100% and will function up to 3 bar(a).
The HPS-100 Hydrogen Process Sensor features reduced power consumption, provides
increased packaging flexibility, and includes a CAN interface with a standard MQS
four-pin connector. Self-testing at start up and advanced error handling ensure reliable
HPS-100 Specifications
Target gas
Concentration range
Accuracy
Resolution
Hydrogen
0–100% H 2 in nitrogen
±2% vol. typical
±0.5% vol.
Speed of response (t90)
< 5 seconds
Speed of recovery
< 5 seconds
Cross-sensitivity
Start-up time
Self test/Error handling
Explosion proof
No detection towards HC, H2S, N2, CO, CO 2, NOx
Humidity influence < 1% typical
operation. In addition, a short-start up time enables an intermittant mode of operation
that minimizes current current consumption better.
The HPS-100 Hydrogen Process Sensor will provide hydrogen detection and measurement for applications where conditions are harsh. With an IP6K9K rating and designed
towards ATEX 100a zone 2, this sensor can be installed almost anywhere.
Benefits
- 0–100% H2
- Designed for humid environment
- Low cross sensitivity
- Fast response time
- Low power consumption
- Long-term stability and reliability
- Long lifetime
5 seconds
Developed in accordance to IEC 61508 (SIL2)
Designed for ATEX 100a, Zone 2
Applications
Electrical
Supply voltage
8.5V–16V
Supply current
70mA typical
Interface
Connector
Mating Connector
ESD/Reverse polarity
-Hydrogen gas measurement in fuel cell systems and other in-process
applications
CAN 2.0 ISO 11898
A2105404381 – Code A
MQS 4-pin, AMP 1-967640-1 Code A
Yes
Environmental
Operation temperature range
-40°C to +95°C
Storage temperature range
-50°C to +95° C
Humidity
5–100% R.H including condensation
Pressure
0.3–3 bar(a)
EMC
Automotive
Shock
Automotive
Vibration
Automotive
Mechanical
Dimensions
L = 93.5 mm, Ø = 30 mm
Weight
77g
Material
Stainless steel and PBT GF30
Gas filter membrane
IP code
Process Connector
Pall SUPOR 450R, 0.45 μm
IP6K7 and IP6K9K
M14x1.5 (ISO-6149-3)
www.ams.com
[email protected]
© 03/2015 by ams
Subject to change without notice
Headquarters
ams AG
Tobelbader Strasse 30, 8141 Unterpremstaetten, Austria
Phone +43 3136 500-0 · Fax +43 3136 525-01
Sales Offices Worldwide
[email protected]
[email protected]