HLS-442 Factsheet

HLS-442
www.ams.com/Hydrogen-Sensors
HLS-442 – Hydrogen Leak Sensor
-Fast and highly selective
-Low power and flexible packaging
-Uniquely designed for superior sensing over wide detection range
We provide innovative
analog solutions to
the most challenging
applications in sensor
and sensor interfaces,
power management,
and wireless.
General Description
The ams HLS-442 Hydrogen Leak Sensor is an accurate, fast responding sensor designed
for installation in vehicles and hydrogen fueling stations. Unlike sensors that can be
extremely cross sensitive to a variety of combustible gases, ams’ HLS-442 sensor was developed using advancements in Field Effect (FE) technology. This enables it to be highly
selective to hydrogen gas without interference from background gases or water vapor.
The HLS-442 incorporates a heated field-effect transistor with a catalytic metal gate
stack as the gas-sensing layer. Hydrogen molecules interact with the gate, thereby changing characteristics of the transistor. The heated transistor also measures the thermal
conducting properties of the gas complementing the field effect signal. Sensor signals
are processed in a microprocessor to provide hydrogen concentration output.
The HLS-442 Hydrogen Leak Sensor features reduced power consumption, provides
increased packaging flexibility, and includes a CAN bus electrical interface with standard
MQS six-pin connector. Self testing at start up and advanced error handling ensure
reliable operation. In addition, a short start up time enables an intermitted mode of
operation that minimizes current consumption better.
ams’ unique design and careful processing of the gate stack result in superior sensor
properties, including high-response speed and excellent selectivity, as well as a
detection range that covers the lower explosion limit of hydrogen gas.
HLS-442 Specifications
Target gas
Concentration range
Accuracy
Hydrogen
0–4.4% H 2 in air
±3000 ppm
Speed of response (t90)
< 2 seconds
Speed of recovery
< 10 seconds
Cross-sensitivity
Start-up time
Self test/Error handling
No detection towards HC, H2S, N2, CO, CO 2, NOx, H2O
Humidity influence, not detectable
1 second
Benefits
-0–4.4% H2
- High sensitivity to hydrogen gas
- Low cross sensitivity
- Fast response time
- Low power consumption
- Long-term stability and reliability
- Long lifetime
Developed in accordance to IEC 61508 (SIL2)
Electrical
Supply voltage
9V–16V
Supply current
75mA typical
Can Interface
Pin selectable CAN ID
Connector
Mating Connector
ESD/Reverse polarity
CAN 2.0 ISO 11898
Yes
A2100011199, 6-PIN Code A
Applications
-Detection of hydrogen gas leaks in the cabin ceiling, under the hood of the
engine compartment, or beneath the trunk lid of hydrogen powered vehicles
- Detection of hydrogen gas in and around hydrogen fueling stations
MQS 6-pin, AMP p/n 1-967616-1 type A
Yes
Environmental
Operation temperature range
Storage temperature range
Humidity
-40°C to +85°C
-50°C to +85°C
0–5% absolute humidity
Pressure
70–130 kPa
EMC
Automotive
ATEX
100a zone 2
Shock
Automotive
Vibration
Automotive
Mechanical
Dimensions (LxWxH)
Weight
Material
Gas filter membrane
IP code
82.2 mm x 42 mm x 17.3 m
50g
PBT GF30
Pall SUPOR 450R, 0.45 μm
IP6K7
www.ams.com
[email protected]
© 03/2015 by ams
Subject to change without notice
Headquarters
ams AG
Tobelbader Strasse 30, 8141 Unterpremstaetten, Austria
Phone +43 3136 500-0 · Fax +43 3136 525-01
Sales Offices Worldwide
[email protected]