IRF HFB06TB120STR

PD-96036
HFA06TB120SPbF.. Series
HEXFRED
Ultrafast, Soft Recovery Diode
TM
Features
• Ultrafast Recovery
• Ultrasoft Recovery
• Very Low IRRM
• Very Low Qrr
• Specified at Operating Conditions
• Lead-Free
(K)
VR = 1200V
BASE
+
2
VF(typ.)* = 2.4V
IF(AV) = 6.0A
Qrr (typ.)= 116nC
IRRM(typ.) = 4.4A
(N/C)
1
-
3
_-
(A)
trr(typ.) = 26ns
di(rec)M/dt (typ.)* = 100A/µs
Benefits
• Reduced RFI and EMI
• Reduced Power Loss in Diode and Switching
Transistor
• Higher Frequency Operation
• Reduced Snubbing
• Reduced Parts Count
D2 Pak
Description
International Rectifier's HFA06TB120S is a state of the art ultra fast recovery diode.
Employing the latest in epitaxial construction and advanced processing techniques it
features a superb combination of characteristics which result in performance which is
unsurpassed by any rectifier previously available. With basic ratings of 1200 volts and 6
amps continuous current, the HFA06TB120S is especially well suited for use as the
companion diode for IGBTs and MOSFETs. In addition to ultra fast recovery time, the
HEXFRED product line features extremely low values of peak recovery current (IRRM) and
does not exhibit any tendency to "snap-off" during the tb portion of recovery. The
HEXFRED features combine to offer designers a rectifier with lower noise and significantly
lower switching losses in both the diode and the switching transistor. These HEXFRED
advantages can help to significantly reduce snubbing, component count and heatsink
sizes. The HEXFRED HFA06TB120S is ideally suited for applications in power supplies
and power conversion systems (such as inverters), motor drives, and many other similar
applications where high speed, high efficiency is needed.
Absolute Maximum Ratings
VR
IF @ T C = 100°C
IFSM
IFRM
PD @ TC = 25°C
PD @ TC = 100°C
TJ
TSTG
Parameter
Cathode-to-Anode Voltage
Continuous Forward Current
Single Pulse Forward Current
Maximum Repetitive Forward Current
Maximum Power Dissipation
Maximum Power Dissipation
Operating Junction and
Storage Temperature Range
Max.
1200
8.0
80
24
62.5
25
-55 to +150
Units
V
A
W
°C
* 125°C
www.irf.com
1
10/07/05
HFA06TB120SPbF..Series
Electrical Characteristics @ TJ = 25°C (unless otherwise specified)
Parameter
VBR
Cathode Anode Breakdown
Min. Typ. Max. Units
1200 ––– –––
V
Test Conditions
IR = 100µA
Voltage
VFM
IRM
Max. Forward Voltage
Max. Reverse Leakage Current
–––
2.7
3.0
–––
3.5
3.9
–––
2.4
2.8
–––
0.26 5.0
–––
110 500
IF = 6.0A
V
IF = 12A
IF = 6.0A, TJ = 125°C
µA
VR = VR Rated
TJ = 125°C, VR = 0.8 x VR RatedD R
CT
Junction Capacitance
–––
9.0
14
pF
VR = 200V
LS
Series Inductance
–––
8.0
–––
nH
Measured lead to lead 5mm from pkg body
Rated
Dynamic Recovery Characteristics @ TJ = 25°C (unless otherwise specified)
Parameter
Reverse Recovery Time
Min. Typ. Max. Units
–––
26
trr1
–––
53
80
trr2
–––
87
130
–––
4.4
8.0
–––
5.0
9.0
–––
116
320
trr
IRRM1
Peak Recovery Current
IRRM2
Qrr1
Reverse Recovery Charge
–––
Qrr2
–––
233
585
di(rec)M /dt1 Peak Rate of Recovery
–––
180
–––
di(rec)M /dt2 Current During tb
–––
100
–––
Test Conditions
IF = 1.0A, dif/dt = 200A/µs, VR = 30V
ns
TJ = 25°C
TJ = 125°C
A
IF = 6.0A
TJ = 25°C
TJ = 125°C
nC
VR = 200V
TJ = 25°C
TJ = 125°C
dif/dt = 200A/µs
TJ = 25°C
A/µs
TJ = 125°C
Thermal - Mechanical Characteristics
Parameter
Min.
Typ.
Max.
Units
Tlead 
Lead Temperature
––––
––––
300
°C
RthJC
Thermal Resistance, Junction to Case
––––
––––
2.0
RthJA ‚
Thermal Resistance, Junction to Ambient
––––
––––
80
RthCSƒ
Thermal Resistance, Case to Heat Sink
––––
0.5
––––
Wt
Weight
––––
2.0
––––
g
––––
0.07
––––
(oz)

‚
2
K/W
0.063 in. from Case (1.6mm) for 10 sec
Typical Socket Mount
www.irf.com
HFA06TB120SPbF..Series
1000
100
TJ = 150˚C
Reverse Current - IR (µA)
100
100˚C
10
1
25˚C
0.1
0.01
0
200 400 600 800 1000 1200 1400
Reverse Voltage - VR (V)
100
1
Junction Capacitance - CT (pF)
Instantaneous Forward Current - IF (A)
10
125˚C
T = 150˚C
J
T = 125˚C
J
T = 25˚C
J
0.1
T = 25˚C
J
10
1
0
2
4
Forward Voltage Drop - VFM (V)
6
1
10
100
1000
10000
Reverse Voltage - VR (V)
Fig. 3 - Typical Junction Capacitance
Vs. Reverse Voltage
Fig. 1 - Typical Forward Voltage Drop Characteristics
Thermal Impedance Z thJC (°C/W)
10
1
D = 0.50
D = 0.20
D = 0.10
D = 0.05
D = 0.02
D = 0.01
PDM
t1
t2
0.1
Single Pulse
(Thermal Resistance)
Notes:
1. Duty factor D = 1t / t2
2. Peak TJ = PDM x ZthJC + TC
0.01
0.00001
0.0001
0.001
0.01
0.1
1
10
100
Fig. 4 - Maximum Thermal Impedance ZthJC Characteristics
www.irf.com
3
HFA06TB120SPbF..Series
25
110
IF = 6 A
IF = 4 A
100
VR = 200V
TJ = 125˚C
TJ = 25˚C
20
90
IF = 6 A
IF = 4 A
15
70
Irr - ( A)
trr - ( nC )
80
60
10
50
40
5
VR = 200V
TJ = 125˚C
TJ = 25˚C
30
20
100
0
100
1000
1000
dif /dt - (A/µs )
dif /dt - (A/µs )
Fig. 5 - Typical Reverse Recovery
Vs. dif /dt
Fig. 6 - Typical Recovery Current
Vs. dif /dt
10000
1000
VR = 200V
TJ = 125˚C
TJ = 25˚C
800
di(REC) M/dt - (A/µs )
Qrr - ( nC )
IF = 6 A
IF = 4 A
600
400
IF = 6 A
IF = 4 A
1000
100
VR = 200V
TJ = 125˚C
TJ = 25˚C
200
0
100
1000
dif /dt - (A/µs )
Fig. 8 - Typical Stored Charge vs. dif /dt
4
10
100
1000
dif /dt - (A/µs )
Fig. 7 - Typical di(REC) M/dt vs. di f /dt
www.irf.com
HFA06TB120SPbF..Series
REVERSE RECOVERY CIRCUIT
VR = 200V
0.01 Ω
L = 70µH
D.U.T.
dif/dt
ADJUST
D
IRFP250
G
S
Fig. 9- Reverse Recovery Parameter Test Circuit
3
t rr
IF
tb
ta
0
Q rr
2
I RRM
4
0.5 I RRM
di(rec)M/dt
5
0.75 I RRM
1
1. dif/dt - Rate of change of
current
through zero
crossing
2. IRRM - Peak reverse
recovery current
di f /dt
4. Qrr - Area under curve
defined by trr and IRRM
trr X IRRM
3. trr - Reverse recovery
Qrr =
2
time measured
from zero
crossing point of negative
going IF to point where a line 5. di(rec)M/dt - Peak rate of
passing through 0.75 IRRM
change of current during t b
and 0.50 IRRM
portion of trr
extrapolated to zero current
Fig. 10 - Reverse Recovery Waveform and Definitions
www.irf.com
5
HFA06TB120SPbF..Series
D2PAK Package Outline
Dimensions are shown in millimeters (inches)
D2PAK Part Marking Information
T HIS IS A HFA06T B120S
INT ERNATIONAL
RECT IF IER
LOGO
(K)
ASS EMBLY
LOT CODE
(N/C) (A)
6
PART NUMBER
DAT E CODE
YY = YEAR
WW = WEEK
P = DES IGNAT ES LEAD-FREE
PRODUCT (OPT IONAL)
www.irf.com
HFA06TB120SPbF..Series
Ordering Information Table
Device Code
HF
A
06
1
2
3
1
-
Hexfred Family
2
-
Process Designator
TB 120
4
5
S
TR
6
7
A = A subs. elec. irrad.
B = B subs. Platinum
3
-
Average Current: Code 06 = 6 AMPS
4
-
Package Outline: Code TB = TO-220 2 Lead
5
-
Voltage code : Code 120 = 1200 V
6
-
Configuration : Code S = SMD
7
-
Suffix : Code TR = Tape and Reel
D2PAK Tape & Reel Information
Dimensions are shown in millimeters (inches)
Data and specifications subject to change without notice.
This product has been designed and qualified for the Consumer market.
Qualifications Standards can be found on IR’s Web site.
IR WORLD HEADQUARTERS: 233 Kansas St., El Segundo, California 90245, USA Tel: (310) 252-7105
TAC Fax: (310) 252-7903
Visit us at www.irf.com for sales contact information.10/05
www.irf.com
7