INFINEON TLE4224-S2

Preliminary data sheet TLE 4224-2/S2
Smart Low-Side Switch
Features
• Power limitation
• Thermal shutdown
• Overload protection
• Short circuit protection
• Diagnostic feedback
• Overvoltage protection
• Reverse polarity protection
• µC compatible input
• Electrostatic discharge (ESD) protection
Product Summary
Supply voltage
Drain source voltage
On resistance
Output current
Application
• All kinds of resistive and inductive loads (relays,electromagnetic valves)
• µC compatible power switch for 12 and 24 V applications
• Solenoid control switch in automotive and industrial control systems
VS
VDS(AZ)max
RON(typ)
ID
6.5 - 45
65
0.25
4
V
V
Ω
A
P - TO220 -7-1
P - TO220 -7-2
General description
Single channel Low-Side Switch in Smart Power Technology (SPT) with µC compatible input and an
open drain DMOS output stage. The TLE 4224-2 is fully protected by embedded protection functions
and designed for automotive and industrial applications.
Block Diagram
VS
VC
VBB
Thermal overload
TLE 4224-2
internal supply
Load
Open Load
Overload
RPD
Semiconductor Group
Page
1
20.12.96
Preliminary data sheet TLE 4224-2/S2
Maximum Ratings for Tj = – 40°C to 150°C
Parameter
Supply voltage
Symbol
VS
VS
Compare voltage
VC
Continuous drain source voltage (OUT)
VDS
Input voltage (IN)
VIN
Status output voltage (ST)
VST
Operating temperature range
Tj
Storage temperature range
Tstg
Output current
ID(lim)
Status output current
IST
Inductive load switch off dissipation energy
Tcase = 125 °C EAS
Tcase = 75 °C
Thermal resistance
junction - case RthJC
junction - ambient RthJA
Supply voltage operational range
Pin Definitions and Functions
Pin Symbol
Values
- 15 ... + 60
Unit
V
+ 5.5 ... + 45
V
- 0.3 ... 65
V
45
V
- 0.3 ... + 6
V
- 0.3 ... + 32
V
- 40 ... + 150
- 55 ... + 150
°C
self limited
A
- 5 ... + 5
mA
100
200
mJ
3
65
K/W
Pin Configuration
Function
1
ST
Status Output (open drain) for error monitoring
2
IN
Control Input, active high
3
ENA
Enable Input, active high
4
GND
Ground, connected internally to cooling lug
5
VC
Compare voltage for open load detection
6
OUT
Power Output (open drain)
7
VS
Supply Voltage
Semiconductor Group
Page
2
20.12.96
Preliminary data sheet TLE 4224-2/S2
Electrical Characteristics
Parameter and Conditions
VS = 6.5 to 45 V ; T j = - 40 °C to + 150 °C
(unless otherwise specified)
Symbol
Values
min
Unit
typ
max
1. Power Supply (VS)
IS
IS
VS
Supply current (Output ON)
Supply current (Output OFF)
VS ≤ 18 V
Operation voltage
5.5
5
mA
1.5
mA
45
V
2. Power Outputs
Tj = 25 ° C
Tj = 150°C
ON state resistance;
ID = 4A
RDS(ON)
0.5
VDS(AZ)
RPD
ton
toff
tfall
trise
t4
t5
tDSO
Z-Diode clamping voltage (OUT)
Tj = 25 ° C
Pull down resistor
1
Output on delay time
Output off delay time 1
Output on fall time 1
Output off rise time 1
Output off status delay time 1
Output on status delay time 1 2
3
Overload switch-off delay time
Ω
0.25
ID = 0.2 A
ID = 2 A
ID = 0.2 A
ID = 2 A
ID = 2 A
45
65
V
14
20
26
kΩ
10
25
50
20
25
40
40
µs
20
50
60
50
150
- 0.3
1.0
V
2.0
6.0
V
0.2
0.6
V
3. Digital Inputs (IN, ENA)
VINL
VINH
VINHys
IIN
IENA
Input low voltage
Input high voltage
Input voltage hysteresis
Input pull down current
Enable pull down current
VS ≥ 9 V; VIN = 5 V
VS ≥ 9 V; VENA = 5 V
50
100
140
µA
5
15
22
µA
0.5
V
10
µA
4. Digital Status Outputs (ST) open Drain
Output voltage low
VSTL
ISTH
IST = 2 mA
Leakage current high
See timing diagram, resitive load condition; VS ≥ 9 V
Time till status valid after switching on or error detection
3
This parameter will not be tested but assured by design
1
2
Semiconductor Group
Page
3
20.12.96
Preliminary data sheet TLE 4224-2/S2
Electrical Characteristics
Parameter and Conditions
VS = 6.5 to 45 V ; T j = - 40 °C to + 150 °C
(unless otherwise specified)
Symbol
Values
min
Unit
typ
max
5. Diagnostic Functions
Open load detection voltage VC = 0 V; 8 ≤ VS ≤ 18 V
(Output OFF)
6.5 ≤ VS ≤ 45 V
VDS(OL)
6.5 ≤ VC ≤ 18 V
Open load compare detection
VDS(OL)C
ID(OL)
ID(lim)
Open load detection current (Output ON)
Overload threshold current
VS ≥ 9.5 V
Tj = 25°C
Tj = 150°C
Overtemperature shutdown threshold
Hysteresis
VC-Input current
4
Tth
Thys
IVC
VC ≤ 18 V
V
0.5*VS
0.6*VS
0.45*VS
0.65*VS
VC -1.6
VC -0.9
V
100
500
mA
5.25
4
A
A
155
185
°C
K
0.25
mA
10
Application Description
This IC is specially designed to drive inductive loads (relays, electromagnetic valves). An integrated
clamp-diode limits the output voltage when inductive loads are discharged.
For the detection of errors there is a open-drain status output, which monitors the following errors by
logic level:
- overloading of output (also shorted load to supply) in active mode
- open and shorted load to ground in active and inactive mode
- thermal overload.
Circuit Description
Input Circuits
The control and enable inputs, all active high, consist of schmitt triggers with hysteresis. All inputs are
connected with pull-down current sources. Not connected inputs are interpreted as LOW.
Switching Stages
The power output consists of a DMOS-power transistor with open drain. The output stage is shorted
load protected troughout the operating range. The integrated clamp-diode limit voltage spikes produced when inductive loads are discharged.
4
This parameter will not be tested but assured by design
Semiconductor Group
Page
4
20.12.96
Preliminary data sheet TLE 4224-2/S2
Protective Circuits
An integrated diode protects the device against reverse polarity of the operating voltage.
The load circuit withstands reverse poling within the limits of the maximum ratings (no shorted load
permissible at the same time).
The outputs are protected against current overload and thermal overload.
Error Detection
The status output signals the switching state at normal operating conditions (LOW = off; HIGH = on)
and in case of errors. The outputs are set according to the diagnostic table below.
If current overload occurs, the error condition is stored into an internal register and the output is shutdown. To reset the register, the control input of the corresponding channel has to be switched off and
then on again.
Open load is detected in on- and off-modus: In on-modus the load current is monitored , in the offmodus the ouput voltage is monitored.
The open load voltage threshold is programmable via the voltage supplied to the VC.
The state of the error detection circuit is directly dependent on the input status.
Diagnostic Table
Enable
Input
Control
Input
Power
Output
Status
Output
ENA
IN
OUT
ST
L
L
OFF
L
L
H
OFF
L
H
L
OFF
L
H
H
ON
H
X
L
OFF
H
X
H
OFF
L
Open Load or
L
L
OFF
H
shorted load to ground
L
H
OFF
H
H
L
OFF
H
H
H
ON
L
Overload or
L
L
OFF
L
shorted load to supply
L
H
OFF
L
H
L
OFF
L
H
H
OFF
L
Operating Condition
Normal Operation
Thermal Overload
L = LOW
H = HIGH
Semiconductor Group
X = RANDOM
Page
5
20.12.96
Preliminary data sheet TLE 4224-2/S2
Test Circuit
VD=5V
VS
VC
470nF
10k
IST
2
V IN
RL
5 I VC 7 Is
VC
VS
1 ST
I IN
V ST
1000u
TLE
4224-2
IN
ID
OUT 6
I ENA
VENA 3
ENA
VDS
GND
4
Application Circuit
VC
C
10k
L
7
Status
Output
1
Control
Input
2
Enable
Input
3
VC
VS
ST
6
OUT
TLE
4224-2
IN
ENA
12 V
GND
4
The blocking capacitor C is recommended to avoid critical negative voltage spikes on V S in
case of battery interruption during OFF-commutating.
Semiconductor Group
Page
6
20.12.96
Preliminary data sheet TLE 4224-2/S2
Timing Diagram
VIN
VI NH
V INL
t
ton
VDS
toff
VS
90%
10%
t
t rise
t fall
VST
t4
t5
t
Overload Current versus temperature
7
6,5
ID(lim) [ A ]
6
5,5
5
4,5
4
3,5
3
-50
-25
0
25
50
75
100
125
150
Junction Temperature [ C ]
Semiconductor Group
Page
7
20.12.96
Preliminary data sheet TLE 4224-2/S2
Package and ordering code
all dimensions in mm
P - TO220 - 7-1
Ordering code
Q67000-A9062
4.6-0.2
1.27
+0.1
2.8
10+0.4
2.6
8.6+/-0.3
7
10.2+/-0.3
1
8.8-0.2
19 max
15.4+/-0.3
3.75+0.1
0.4+0.1
0.6+0.1
1.27
3.9+/-0.3
6x1.27=7.62
8.4+/-0.3
10.2-0.2
P - TO220 - 7-2
Ordering code
Q67000-A9279
Semiconductor Group
Page
8
20.12.96