INFINEON Q62705-K227

Hall Sensor
KSY 14
Features
•
•
•
•
•
•
•
•
•
High sensitivity
High operating temperature
Small linearity error
Low offset voltage
Low TC of sensitivity and
internal resistance
Ultra-flat plastic miniature
package
Low inductive zero component
Package thickness 0.7 mm
Connections from one side of
the package
Typical applications
• Current and power
measurement
• Magnetic field measurement
• Control of brushless DC motors
• Rotation and position sensing
• Measurement of diaphragm
• Movement for pressure
sensing
Dimensions in mm
Type
Marking
Ordering Code
KSY 14
14
Q62705-K227
The KSY 14 is an ion-implanted Hall sensor generator in a mono-crystalline GaAs
material, built into an extremely flat plastic package (SOH). It is outstanding for a high
magnetic sensitivity and low temperature coefficients. The 0.35 × 0.35 mm2 chip is
mounted onto a non-magnetic leadframe.
Semiconductor Group
1
07.96
KSY 14
Maximum ratings
Parameter
Symbol
Value
Unit
Operating temperature
TA
Tstg
I1
GthA
GthC
– 40…+ 175
°C
– 50…+ 180
°C
7
mA
≥ 1.5
≥ 2.2
mW/K
mW/K
5
mA
Open-circuit sensitivity
I1N
KB0
190…260
V/AT
Open-circuit Hall voltage
V20
95…130
mV
Ohmic offset voltage
I1 = I1N, B = 0 T
VR0
≤ ± 20
mV
Linearity of Hall voltage
B = 0…0.5 T
B = 0…1 T
FL
≤ ± 0.2
≤ ± 0.7
%
%
R10
R20
TCV20
900…1200
Ω
900…1200
Ω
∼ – 0.03…– 0.07
%/K
Temperature coefficient of the internal
resistance
B=0 T
TCR10, R20
∼ 0.1…0.18
%/K
Change of offset voltage within the
temperature range
∆VR01)
≤2
mV
Inductive zero component
I1N = 0
A2 2)
0.16
cm2
Noise figure
F
∼ 10
dB
Storage temperature
Supply current
Thermal conductivity
soldered, in air
Characteristics (TA = 25 °C)
Nominal supply current
I1 = I1N, B = 0.1 T
Input resistance
Output resistance
B=0 T
B=0 T
Temperature coefficient of the
open-circuit Hall voltage
I1 = I1N, B = 0.1 T
1) AQL: 0.65
2) With time varying induction there exists an inductive voltage Vind between the Hall voltage terminals (supply
current I1 = 0):
Vind = A2 × dB/dt × 10-4 with V(V), A2 (cm2), B(T), t(s)
Semiconductor Group
2
KSY 14
Connection of a Hall sensor with a power source
Since the voltage on the component must not exceed 10 V, the connection to the
constant current supply should only be done via a short circuit by-pass. The by-pass
circuit-breaker shall not be opened before turning on the power source, in order to avoid
damage to the Hall sensor due to power peaks.
Polarity of Hall voltage
Semiconductor Group
3