APT30DL60B(G) APT30DL60S(G) 600V 30A *G Denotes RoHS Compliant, Pb Free Terminal Finish. Ultrasoft Recovery Rectifier Diode (B) PRODUCT APPLICATIONS PRODUCT FEATURES PRODUCT BENEFITS • Anti-Parallel Diode -Switchmode Power Supply -Inverters • Ultrasoft Recovery Times (trr) • Soft Switching - High Qrr • Popular TO-247 Package or Surface Mount D3PAK Package • Low Noise Switching - Reduced Ringing • Ultra Low Forward Voltage • Higher Reliability Systems • Low Leakage Current • Minimizes or eliminates snubber • Applications - Induction Heating • Resonant Mode Circuits -ZVS and ZCS Topologies - Phase Shifted Bridge TO - 24 7 D3PAK 1 2 1 2 (S) 2 1 1 - Cathode 2 - Anode Back of Case - Cathode All Ratings : TC = 25°C unless otherwise specified. MAXIMUM RATINGS Symbol VR Characteristic / Test Conditions Ratings Unit 600 Volts Maximum D.C. Reverse Voltage VRRM Maximum Peak Repetitive Reverse Voltage VRWM Maximum Working Peak Reverse Voltage IF(AV) Maximum Average Forward current (TC = 126°C, Duty Cycle = 0.5) 30 IF(RMS) RMS Forward Currrent (Square wave, 50% duty) 51 Non-Repetitive Forward Surge Current (TJ = 45°C, 8.3 ms) 110 IFSM TJ, TSTG TL Operating and Storage Junction Temperature Range Amps -55 to 175 °C Lead Temperature for 10 Seconds 300 STATIC ELECTRICAL CHARACTERISTICS VF Characteristic / Test Conditions Forward Voltage IRM Maximum Reverse Leakage Current CT Junction Capacitance, VR = 200V Min Typ Max IF = 30A 1.25 1.6 IF = 60A 2.03 IF = 30A, TJ = 125°C 1.9 Volts VR = 600V 25 VR = 600V, TJ = 125°C 250 μA 31 Microsemi Website - http://www.microsemi.com Unit pF 052-6313 Rev B 6 - 2009 Symbol APT30DL60B_S(G) DYNAMIC CHARACTERISTICS Symbol Characteristic / Test Conditions trr Reverse Recovery Time trr Reverse Recovery Time Qrr Reverse Recovery Charge IRRM Maximum Reverse Recovery Current trr Min Typ IF = 1A, diF/dt = -100A/μs, VR = 30V, TJ = 25°C Reverse Recovery Charge IRRM Maximum Reverse Recovery Current trr Reverse Recovery Time Qrr Reverse Recovery Charge IRRM Maximum Reverse Recovery Current Unit 64 ns 317 IF = 30A, diF/dt = -200A/μs VR = 400V, TC = 25°C Reverse Recovery Time Qrr Max IF = 30A, diF/dt = -200A/μs VR = 400V, TC = 125°C IF = 30A, diF/dt = -1000A/μs VR = 400V, TC = 125°C 962 nC 7 Amps 561 ns 2244 nC 9 Amps 264 ns 3191 nC 26 Amps THERMAL AND MECHANICAL CHARACTERISTICS Symbol Characteristic / Test Conditions RθJC Junction-to-Case Thermal Resistance WT Min Typ Unit .88 °C/W 0.22 oz 5.9 g Package Weight Torque 0.9 0.8 0.7 0.6 0.5 0.4 Note: 0.3 PDM ZθJC, THERMAL IMPEDANCE (°C/W) 10 lb·in 1.1 N·m Maximum Mounting Torque Microsemi reserves the right to change, without notice, the specifications and information contained herein. 0.2 t1 t2 t Duty Factor D = 1/t2 Peak TJ = PDM x ZθJC + TC 0.1 0 10-5 10-4 10-3 10-2 10-1 1.0 RECTANGULAR PULSE DURATION (seconds) FIGURE 1. MAXIMUM EFFECTIVE TRANSIENT THERMAL IMPEDANCE, JUNCTION-TO-CASE vs. PULSE DURATION 052-6313 Rev B 6 - 2009 Max APT30DL60B_S(G) TYPICAL PERFORMANCE CURVES 800 100 TJ= 125°C TJ= 150°C 60 TJ= 25°C 50 40 30 20 10 0 Qrr, REVERSE RECOVERY CHARGE (nC) TJ= 55°C 70 0 0.5 1.0 1.5 2.0 2.5 3.0 VF, ANODE-TO-CATHODE VOLTAGE (V) FIGURE 2, Forward Current vs. Forward Voltage 4500 T = 125°C 60A J V = 400V R 4000 3500 30A 3000 2500 15A 2000 1500 1000 500 0 15A 400 300 200 100 0 200 400 600 800 1000 -diF/dt, CURRENT RATE OF CHANGE (A/μs) FIGURE 3, Reverse Recovery Time vs. Current Rate of Change 32 T = 125°C J V = 400V 28 60A R 30A 24 15A 20 16 12 8 4 0 0 200 400 600 800 1000 -diF/dt, CURRENT RATE OF CHANGE (A/μs) FIGURE 5, Reverse Recovery Current vs. Current Rate of Change 70 60 1 IRRM 0.8 50 tRR 0.6 QRR 0.4 40 30 20 0.2 0 30A 500 0 IF(AV) (A) Kf, DYNAMIC PARAMETERS (Normalized to 1000A/μs) 0 200 400 600 800 1000 -diF/dt, CURRENT RATE OF CHANGE (A/μs) FIGURE 4, Reverse Recovery Charge vs. Current Rate of Change 1.2 R 60A 600 IRRM, REVERSE RECOVERY CURRENT (A) IF, FORWARD CURRENT (A) 80 T = 125°C J V = 400V 700 trr, COLLECTOR CURRENT (A) 90 10 0 25 50 75 100 125 150 TJ, JUNCTION TEMPERATURE (°C) FIGURE 6, Dynamic Parameters vs Junction Temperature 0 Duty cycle = 0.5 TJ = 126°C 25 50 75 100 125 150 175 Case Temperature (°C) FIGURE 7, Maximum Average Forward Current vs. Case Temperature 250 200 150 100 50 0 1 10 100 400 VR, REVERSE VOLTAGE (V) FIGURE 8, Junction Capacitance vs. Reverse Voltage 052-6313 Rev B 6 - 2009 CJ, JUNCTION CAPACITANCE (pF) 300 APT30DL60B_S(G) Vr diF /dt Adjust +18V 0V D.U.T. trr/Qrr Waveform CURRENT TRANSFORMER Figure 9. Diode Test Circuit 1 IF - Forward Conduction Current 2 diF /dt - Rate of Diode Current Change Through Zero Crossing. 3 IRRM - Maximum Reverse Recovery Current. 4 trr - Reverse Recovery Time, measured from zero crossing where diode current goes from positive to negative, to the point at which the straight line through IRRM and 0.25 IRRM passes through zero. 1 4 6 Zero 5 5 Qrr - Area Under the Curve Defined by IRRM and trr. 6 diM/dt - Maximum Rate of Current Increase During the Trailing Portion of trr. 0.25 IRRM 3 Slope = diM/dt 2 Figure 10, Diode Reverse Recovery Waveform and Definitions 3 D PAK Package Outline TO-247 Package Outline e1 SAC: Tin, Silver, Copper 15.49 (.610) 16.26 (.640) 6.15 (.242) BSC 5.38 (.212) 6.20 (.244) 4.90 (.193) 5.10 (.201) 1.45 (.057) 1.60 (.063) 15.85 (.624) 16.05(.632) 1.00 (.039) 1.15(.045) Cathode 20.80 (.819) 21.46 (.845) 0.40 (.016) 0.65 (.026) 0.40 (.016) 0.79 (.031) 1.65 (.065) 2.13 (.084) 19.81 (.780) 20.32 (.800) 1.01 (.040) 1.40 (.055) 0.020 (.001) 0.250 (.010) 2.70 (.106) 2.90 (.114) 1.15 (.045) 1.45 (.057) 1.20 (.047) 1.90 (.075) 1.40 (.055) 2.10 (.083) 5.45 (.215) BSC (2 Plcs.) Anode 2.21 (.087) 2.59 (.102) Cathode 10.90 (.430) BSC Dimensions in Millimeters and (Inches) 13.30 (.524) 13.60(.535) 12.40 (.488) 12.70 (.500) 18.70 (.736) 19.10 (.752) 3.50 (.138) 3.81 (.150) 4.50 (.177) Max. 052-6313 Rev B 6 - 2009 Cathode (Heat Sink) 4.69 (.185) 5.31 (.209) 1.49 (.059) 2.49 (.098) e1 100% Sn Anode Cathode Dimensions in Millimeters (Inches) 2.40 (.094) 2.70 (.106) (Base of Lead) Heat Sink (Cathode) and Leads are Plated