PLP-45 45W Single Output LED Power Supply series Features : Universal AC input / Full range Protections: Short circuit / Over current / Over voltage Built-in active PFC function Cooling by free air convection Class 2 power unit Output current level adjustable 100% full load burn-in test High reliability Suitable for built-in applications of LED lighting 2 years warranty ( for 48V only) SPECIFICATION MODEL DC VOLTAGE PLP-45-12 PLP-45-24 PLP-45-48 12V 24V 48V 18 ~ 24V 36 ~ 48V 0.95A CONSTANT CURRENT OPERATION VOLTAGE Note.5 9 ~ 12V OUTPUT RATED CURRENT 3.8A 1.9A CURRENT RANGE 0 ~ 3.8A 0 ~ 1.9A 0 ~ 0.95A RATED POWER 45.6W 45.6W 45.6W 3.8Vp-p 4.8Vp-p 1.425 ~ 1.9A 0.715 ~ 0.95A RIPPLE & NOISE (max.) Note.2 4.2Vp-p CURRENT ADJ. RANGE 10% LINE REGULATION 3.0% 5.0% 1000ms / 230VAC 2000ms / 115VAC at full load SETUP TIME VOLTAGE RANGE Note.4 90 ~ 264VAC 47 ~ 63Hz POWER FACTOR (Typ.) PF 0.9 at 75 ~ 100% load, 115VAC / 230VAC EFFICIENCY (Typ.) 86% AC CURRENT (Typ.) INRUSH CURRENT (max.) 0.6A/115VAC 42A/230VAC LEAKAGE CURRENT <0.75mA / 240VAC Note.5 PROTECTION SHORT CIRCUIT OVER VOLTAGE WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT EMC OTHERS 89% 89% 0.3A/230VAC 100 ~ 110% Protection type : Constant current limiting, recovers automatically after fault condition is removed Protection type : Hiccup mode, recovers automatically after fault condition is removed 15 ~ 18V 28 ~ 35V 57 ~ 63V Protection type : Shut down o/p voltage, re-power on to recover -30 ~ +70 (Refer to "Derating Curve") 20 ~ 95% RH non-condensing -40 ~ +80 , 10 ~ 95% RH 0.03%/ (0 ~ 50 ) VIBRATION 10 ~ 500Hz, 2G 12min./1cycle, period for 72min. each along X, Y, Z axes SAFETY STANDARDS UL8750, TUV EN61347-1, EN61347-2-13, CSA C22.2 No. 250.0-08(except for 48V) approved ; design refer to UL60950-1 WITHSTAND VOLTAGE ISOLATION RESISTANCE EMC EMISSION I/P-O/P:3.75KVAC I/P-FG:1.88KVAC O/P-FG:0.5KVAC I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH Compliance to EN55015, EN61000-3-2 Class C( 75% load); EN61000-3-3 EMC IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024,EN61547, light industry level, criteria A MTBF 586.5Khrs min. DIMENSION 101.6*50.8*29.6mm (L*W*H) 0.16Kg; 96pcs/16.4Kg/0.89CUFT PACKING NOTE 127 ~ 370VDC FREQUENCY RANGE OVER CURRENT SAFETY & 2.85 ~ 3.8A VOLTAGE TOLERANCE Note.3 LOAD REGULATION INPUT ( except for 48V ) MIL-HDBK-217F (25 ) 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Derating may be needed under low input voltage. Please check the static characteristics for more details. 5. Constant current operation region is within 75% ~100% rated output voltage. This is the suitable operation region for LED related applications, but please reconfirm special electrical requirements for some specific system design. 6. Heat sink HS1,HS2 can not be shorted. 7. Heat sink HS1 must have safety isolation distance with system case. 8. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again. 9. Direct connecting to LEDs is suggested, but is not suitable for using additional drivers. File Name:PLP-45-SPEC 2012-03-01 PLP-45 45W Single Output LED Power Supply Mechanical Specification series Unit:mm 101.6 3.175 . 50.8 . 44.45 3.175 95.25 HS1 HS2 FS1 1 2 3 CN1 CN2 SVR1 1 2 4- 29.6 3.2 3max. 1.HS1,HS2 can not be shorted. 2.HS1 must have safety isolation distance with system case. AC Input Connector (CN1) : JST B3P-VH or equivalent Pin No. 1 2 3 Assignment AC/L No Pin AC/N DC Output Connector (CN2) : JST B2P-VH or equivalent Mating Housing Terminal JST VHR or equivalent JST SVH-21T-P1.1 or equivalent Pin No. 1 2 Assignment +V -V Mating Housing Terminal JST VHR or equivalent JST SVH-21T-P1.1 or equivalent : Grounding required Block Diagram fosc : 90KHz(115VAC) 120KHz(230VAC) EMI FILTER & RECTIFIERS I/P RECTIFIERS & FILTER POWER SWITCHING FG +V -V DETECTION CIRCUIT O.L.P. PWM & PFC CONTROL O.C.P. O.V.P. Derating Curve Static Characteristics 100 100 90 80 80 70 50 LOAD (%) LOAD (%) 60 40 20 -30 -25 -5 0 20 40 50 AMBIENT TEMPERATURE ( ) 60 70 (HORIZONTAL) 60 50 40 90 100 125 135 145 155 165 175 180 200 230 264 INPUT VOLTAGE (V) 60Hz File Name:PLP-45-SPEC 2012-03-01 PLP-45 45W Single Output LED Power Supply series Power Factor Characteristic PF Constant Current Mode 1 0 0 0 0 0 0 0 0 0 0 0 .0 .9 .9 .9 .9 .9 .8 .8 .8 .8 .8 .7 0 8 6 4 2 0 8 6 4 2 0 8 230V 115V 50% 60% 70% 80% 90% 100% (45W) LOAD EFFICIENCY vs LOAD (48V Model) EFFICIENCY (%) PLP-45 series possess superior working efficiency that up to 89% can be reached in field applications. 94 92 90 88 86 84 82 80 78 76 74 72 70 68 66 64 62 60 58 230V 115V 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% LOAD DRIVING METHODS OF LED MODULE This LED power supply is suggested to work in constant current mode area (CC) to drive the LEDs. 100 Vo(%) Constant Current area 75 (max.) Hiccup Protection 50 100 Io (%) Typical LED power supply I-V curve File Name:PLP-45-SPEC 2012-03-01